Documentos de Académico
Documentos de Profesional
Documentos de Cultura
Cortes
Cortes
Cortes
S.H.
CLOSET
PASADIZO
DORMITORIO
DORMITORIO
S.H.
CLOSET
PASADIZO
DORMITORIO
DORMITORIO
PASADIZO
PASADIZO
DORMITORIO
DORMITORIO
S.H.
DORMITORIO
DORMITORIO
S.H.
DORMITORIO
DORMITORIO
DORMITORIO
S.H.
DORMITORIO
DORMITORIO
S.H.
DORMITORIO
BAR
LOCAL
LOCAL
TIENDA
TIENDA
TIENDA
TALLER
S.H.
TIENDA
CORTE B-B
VESTIDOR
TIENDA
CORTE A-A
HOSTAL ESTRELLA
SALOON
SUING
OPEN
NIV0.00
SR : PABLO HUAMANTUPA HUAMANTUPA
SRA:REMIGIA HUARAYO TECSI de HUAMANTUPA
CORTE Y FACHADA
FACHADA
TIENDAS -COMERCIO
PISO
C-1
C-2
C-3
0.20x0.40
0.20X0.50
0.15x 0.40
TIPOS
DIMENSION
1 @ 0.05, 5 @ 0.10 y
rto. @ 0.25 en c/ext.
Cap=10
M3
ESTRIBOS
1 @ 0.05, 5 @ 0.10 y
rto. @ 0.25 en c/ext.
C-4
P-1
0.15x 0.25
1 @ 0.05, 5 @ 0.10 y
rto. @ 0.25 en c/ext.
C-C
0.15x0.60
R= .30
en suncho
0.20
.15
.15
.20
2.70
.40
SECCION
.25
.60
.40
LOSA o VIGA
0.20
0.25
NOTAS:
CC - 3
V.C .15X.40
C-1
V.C .15X.40
P-1
C-1
1.50 - 2.00
V.C .15X.40
C-3
C-1
L
1.00 - 1.50
2.00 - 2.50
C-3
Z-3
2.50 - 3.00
h
0.15
ANCHO DE
MURO
V.C .15X.40
CC - 3
CC - 3
C-1
CC - 3
CC - 3
h = 0.60 m
NSZ = - 0.50
NFZ = -1.50
2@.10 rto.@.20
-----
2@.10 rto.@.20
0.25
3@.10 rto.@.20
CONCRETO ARMADO
0.30
4@.10 rto.@.20
CONCRETO
CONTROL
TALLER
OBSERVACIONES :
DESPUES DEL DESENCOFRADO DEL TECHO , CON LADRILLO PANDERETA.
C-3
1/7 L
CORTE B-B
L
SS.HH
.30
:f'm 65 Kg / Cm2
ESPESOR MINIMO
% MAXIMO DE VACIOS
cimentacion
escalera
12
P-1
.90
ESTAR
T.V
Z-1
h = 0.60 m
NSZ = - 0.50
NFZ = -1.50
C2
TIENDA
V.C 103
V.C .15X.40
C-3
h = 0.60 m
NSZ = - 0.50
NFZ = -1.50
Z-3
P-1
C-1
V.C .15X.40
V.C .15X.40
Z-2
h = 0.60 m
NSZ = - 0.50
NFZ = -1.50
CC - 3
CC - 3
h = 0.60 m
NSZ = - 0.50
NFZ = -1.50
CC - 3
h = 0.60 m
NSZ = - 0.50
NFZ = -1.50
Z-4
h = 0.60 m
NSZ = - 0.50
NFZ = -1.50
C-1
.80
.20
.10
.20
.25
C
NFP= + 0.10
.20
ESC. 1/25
2.90
.20
.40
cimentacion
escalera
ESTRIBOS
.80
1.40
0.25
.60
B
.07
(malla)
.30
V.C .15X.40
(tipico)
6 mm
30
8 mm
3/8"
40
50
1/2"
50
60
5/8"
60
70
3/4"
70
90
.15
Nivel
agua
NFC = -3.05
CENTRAL O LATERAL
.30
1"
COLUMNAS
(malla)
LOSAS Y VIGAS
NFC = -1.50
0.10
e=0.025 m junta
de seraracion sismica.
LOSAS COLUMNAS
VIGAS
(cm)
(cm)
TAPA SANITARIA
PVC (HD) (60X60)
.30
(ver planta)
0.25
NFC = -1.50
C-3
C-3
C-3
V.C .15X.40
V.C .15X.40
C-3
CC - 5
V.C .15X.40
C-4
Z-4
Z-4
LOSA o VIGA
C-3
h = 0.60 m
NSZ = - 0.50
NFZ = -1.50
V.C .15X.40
1.35
C-2
C-4
C-1
CC - 1
CC - 2
CC - 2
CC - 2
Z-2
C-1
.20
ESPESOR
n.f.p
+10
VIGA DE AMARRE
.30 .50
CC - 3
C-4
CC - 2
CC - 5
C-2
CC - 4
CC - 4
n.f.p
0.00
.20
SECCCION B - B
CONSERJERIA
CC - 4
V.C .15X.40
V.C .15X.40
CC - 4
CC - 1
TIENDA
.10
.20
h = 0.60 m
NSZ = - 0.50
NFZ = -1.50
TIENDA
.30
C-3
C-2
V.C 103
V.C .15X.40
V.C 103
TIENDA
24
NOTA :
0.25
C-C
Z-2
0.20
h = 0.60 m
NSZ = - 0.50
NFZ = -1.50
P-1
: e max : =1.5 Cm
NFP = -1.00
(ver detalle tipico)
Z-2
CC - 4
: e min: =0.9 Cm
ASCENSOR
: 30 %
MORTERO
V.C 103
V.C 103
: 7.5 Cm
C-2
1/7 L
CC - 4
ZAPATAS
C-2
C-4
: 4 Cm
: 2.5 Cm
: 2 Cm
TERRENO
TALLER
TALLER
1/5 L
1/5 L
h = 0.60 m
NSZ = - 0.50
NFZ = -1.50
C-4
: fy = 4200 Kg/cm2
RECUBRIMIENTOS
Z-2
C-4
ACERO REFUERZO
TALLER
C-2
CONCRETO CICLOPEO
0.20
120
110
NO SE PERMITIRAN
EMPALMES DEL REFUERZO
SUPERIOR (NEGATIVO) EN
UNA LONGITUD DE 1/4
DE LUZ DE LA LOSA O
VIGA A CADA LADO DE
LA COLUMNA O APOYO
LOS EMPALMES L
SE UBICARAN EN EL
TERCIO CENTRAL
NO SE EMPALMARAN
MAS DEL 50% DE LA
ARMADURA EN UNA
MISMA SECCION
Rmax
1/4"
10 cm
1.5 cm
3/8"
15 cm
2.0 cm
2.40
(tipico)
2.00
0.20
0.15
0.20
NPT = (ver plano)
.25
.10
.10
.35
SECCION VC - 01
.20
.10
.10
SOBRE CIMIENTO
.35
.50
VIGA DE CIMENTACION
DE.15X.40 6 DE 1/2"
VIGA DE CIMENTACION
DE.15X.40 6 DE 1/2"
VIGA DE CIMENTACION
DE.15X.40 6 DE 1/2"
SECCION VC - 01
0.15
.10
.80
.80
.35
.10
1.15
.30
.30
1.15
NIVEL DE PISO
CIMIENTO
1.15
NFC = -.95
.40
NFC = -1.50
CORTE -A A
.20
0.40
CC - 1
0.40
0.40
CC - 4
.30
.15
1.60
.15
.10
ESC. 1/25
.30
CIMENTACION
CC - 5
CC - 3
CC - 2
.50
CC - 3
.80
.30
.10
NFC = -1.50
0.40
.30
.60
NFC = -1.50
TIENDAS -COMERCIO