CHEMETRON High Pressure Carbon Dioxide GENERAL INFORMATION HIGH PRESSURE CO, EQUIPMENT DESCRIPTION ‘Chemetron High Pressure Carbon Dioxide fire extinguish- ing systems provide protection fora variety of industrial applications. High Pressure CO, systems consist of four | CYLINDER AND VALVE AssEMBLY ' basic components and thelr associated accessories. The cylinders that are used to store CO, are spun steel containers manufactured to DOT 1 Storage / Distribution Components Specification 3AA-1800 or 3AAA-1800 or high: Completer Kiss er. They are available in five diferent capaci- (> = Control Panels ties ~25 lb (12 kg}, 35 Ib. (16 kg, 50 Ib. (23 kg), 1 Detection and Alarm Devices 75 lb (34 ka) and 100 Ib (45 kg) sizes. Each cy- linder is stamped with a serial number and FEATURES hydrostatic test date. They also come equipped [7] The storagerdistbution components consist ofthe with a steel cap for the physical protection of oylinders and valves, support and racking com- the oylinder valve during shipment and han- The Primary Completer Kit includes a pilot discharge pene claerasembly composed i ead, pilot solenoid, pilot cont it, discharge aoylinder, rigic tube, and valve. It is de- ree pe ees arecte signed for vertical mounting only. ponents, and discharge nozzles. ding. | hose, warning sign, and manual operating instruc- Pict tion plate. The Slave Completer Kit includes a slave , discharge head and discharge hose. ' vaso wee J [BJ The control pane! monitors the detection and a actuation devices and includes timers to delay the cos oiscspsce discharge, allowing for safe departure from the : > protected space _gggere eecbuewy | The detection and alarm devices are the external wae components that provide audible or visual signals to enescune osuee — X888iawy alert occupants of pending problems or the possible Suen SAEETY nase need to evacuate the protected space prior to ASSmIELY discharge. Carton dose stems cant designe rl foodng f and local application protection. The uidelines contained co \ in the National Fire Protection Assocation Standard on ‘Acnder Valve &Ducarge Head (Piet) \__- Carbon Dioxide (NFPA 12) and OSHA standards, as well as -siave state and local requirements shouldbe followed fr either : =n stock Cinder Ay Dimensions design. total flooding system canbe defined a injecting haces tte CO, into a room, area or compartment that has the struc- site| Stan weiner [Diameter tural integrity to retain the agent once it has been dis- mented » [= [Lo charged. The minimum concentration requirement for 25 | ossr493 nesta 1525 [asa [159 total flooding systems is 34% by volume. This minimum coe Teaarapr SA ee concentration is suitable for a wide range of ordinary x a [03a | a5 [2191 combustibles and flammable liquids. Higher conceatra- a sae ssa tions may be required fr specific ammableliquds and/or 7oe [semana co-ve [4 [os | 2365, hazards that may become deep seated. The local applic- roo | oneo04| ie [587 [| 2699 tion method requires that CO, be applied tothe surface of Fah to of cnde ale to boiom fines the protected hazard for a specified time period that lore winterzed cinder asenbls 90% CO, fl pressured insures the fre condition has been controlled. with Nrogent 1050 PSat 70-7 ore made lnal ‘finder see, {© 2000 Chemetron Fire Systems. Allrghts reserved (800). Chemetvon Fire Systems and Cardox are registered trademarks, CHEMETRON Fire Systems woxofaarans © ‘Sn s0260263// ay & : Plot opeRATED wor (2 oischance nex DiscHARGE S S em “a7 : iS Somes Sin 0810148 cyUNDER ischarge “CYLINDER Head & Valve A Exploded View of a Pilot Cylinder Assembly osofance =) “Ky \\ fe sl stave operateD jpiscnanee HEAD o nssewaly Env roeror1s “CYLINDER VALVE Il ‘Sm tostora0 cYUNDER VALVE “AsSlave Discharge | covunoer Head & Valve | ‘A Exploded View of a Slave Cylinder Assembly *Part of Cylinder Assembly High Pressure Carbon Dioxide Cylinder: The steel cylinders are manufactured to the requirements of the U.S. Department of Transpor- tation (DOT) for compressed gas storage, specifica- tion 3AA-1800 or 3AAA-1800 or higher. ‘Siphon Tube: A" (19 mm) threaded stainless stee! tube with a wall thickness of 035" (.89 mm) extends from the cylinder valve down to the bottom of the oylinder, Cylinder Valve: A pressure operated cylinder valve consisting of a forged brass body with an external disc cartier and seat disc held in the normally closed position by a spring and cylinder pressure, The valve hhas been designed to take advantage of a 7 to 1 seat to piston ratio, which assures consistent operation, ‘The bodyis designed with multiple threaded connec- tions which accommodate the discharge head and cylinder. In addition, the following connections are provided: Safety Disc (S/N 50610624): A frangible safety discis required for connection to the valve body and serves as a pressure relief device to protect the cylinder and personnel in case of excessive internal pressure. The disc is designed to rupture When it is exposed to pressures between 2850 and 3000 psi (16,203 to 20,685 kPa) created by high temperatures. Fill Check (S/N 30610033): The filling port con- tains a check valve type device that also serves {asa connection for the attachment of a solenoid pilot valve, as well as a port to fill the cylinders. The threads for attachments are 825-14NGO- RH-EXT (CGA No. 320) Discharge Head: Each cylinder requires the addition ofa discharge head to open its valve. The discharge head is attached to the cylinder by means ofa swivel rut that engages the threads of the valve. Three different types of discharge heads can be used: 2) pilot operated type with handwheel for manual operation ») pilot operated type without handwheel pressure operated type Each of the three types includes an intemal oper- ating piston connected to a hollow stem thatis used to upset the cylinder seat disc when operated, which allows the agent to ext. A stainless steel ball check at the top of the stem provides a safety fea- ture to prevent excessive loss of carbon dioxide from the manifold if the system is discharged during servicing, (© 2000 Chemetron Fire Systems. All rights reserved (6/00). Chemetion Fite Systems and Cardox are registered tradematks. CHEMETRON Fire Systems COMPLETER KIT - PRIMARY ‘Two types of completer kits that contain the necessary components required to make the cylinder functional are available, ‘Completer Kits Primary | Slave 20480483 | 20480486 Description Quantity |" Quantity Pilot cylinder hose kit 1 ° Solenoid valve 1 o Warning sign | 1 2 fir Discharge hove 7 1 Instruction sign 1 0 Pilot discharge head 1 o Slave discharge head 0 1 if cylinders are used in a Main/Reserve system, order decals: ain Decal -S/N 50360753 __ Reserve Decal S/N 50360752 PioT OPERATED HEAD WITH HANDWHEEL Stock Number 30610143 ye wer ron eine ys set ton Le | This discharge head is designed with a %" (6 mm) NPT connection for pilot pressure entry to the top of an internal piston for valve operation. It is used on the actuation

También podría gustarte