Está en la página 1de 1

1x30 A

C-2

1x20 A

CIRCUITOS
DERIVADOS

INTERRUPTOR
PRINCIPAL

MEDIDOR

ACOMETIDA

DIAGRAMA UNIFILAR
INDIVIDUAL

1-8 d

1x15 A

C-1

N
CIRCUITO

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47

180W
40W

1800W

90W

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
-

1500W

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
-

WATTS

3750
840
3750
840
3750
840
3750
840
3750
840
3750
840
3750
840
3750
840
3750
840
3750
840
3750
840
3750
840
3750
840
3750
840
3750
840
3750
840
3750
840
3750
840
3750
840
3750
840
3750
840
429
184
223
540
-

AMP.

17.71
5.29
17.71
5.29
17.71
5.29
17.71
5.29
17.71
5.29
17.71
5.29
17.71
5.29
17.71
5.29
17.71
5.29
17.71
5.29
17.71
5.29
17.71
5.29
17.71
5.29
17.71
5.29
17.71
5.29
17.71
5.29
17.71
5.29
17.71
5.29
17.71
5.29
17.71
5.29
17.71
5.29
5.29
1.8
2.8
2.55
-

127

127
127
127
127
127
127
127
127

127
127
127
127
127
127
127

127
127
127
127
127

127
127

127
127
127
127
127

127
127
127
127
127
127
127

127
127
127
127
127
127
127

127
127
127
127
127

VOLTS

1x20 A

1x15 A

1x15 A

1x15 A

1x15 A

1x15 A

1x20 A

1x15 A

1x20 A

1x15 A

1x20 A

1x15 A

1x20 A

1x15 A

1x20 A

1x15 A

1x20 A

1x15 A

1x20 A

1x15 A

1x20 A

1x15 A

1x20 A

1x15 A

1x20 A

1x15 A

1x20 A

1x15 A

1x20 A

1x15 A

1x20 A

1x15 A

1x20 A

1x15 A

1x20 A

1x15 A

1x20 A

1x15 A

1x20 A

1x15 A

1x20 A

1x15 A

1x20 A

1x15 A

1x20 A

1x15 A

PROTECCION

CARGADO A LA FASE

CUADRO DE CARGAS GENERAL, RESUMEN DE CARGAS ELCTRICAS INSTALADAS (CIRCUITOS DERIVADOS)

23W

2
1
4
3
2
1
4
3
2
1
4
3
2
1
4
3
2
1
4
3
2
1
4
3
2
1
4
3
2
1
4
3
2
1
4
3
2
1
4
3
2
1
4
3
2
1
4
3
2
1
4
3
2
1
4
3
2
1
4
3
2
1
4
3
2
1
4
3
2
1
4
3
2
1
4
3
2
1
4
3
2
1
4
3
9
3
8
5
1
3
BOMBA HIDRULICA

e%
1.04
0.41
1.04
0.41

1.04
0.41
1.04
0.41
1.04
0.41
1.04
0.41
1.04
0.41
1.04
0.41
1.04
0.41
1.04
0.41
1.04
0.41
1.04
0.41
1.04
0.41
1.04
0.41
1.04
0.41
1.04
0.41
1.04
0.41
1.04
0.41
1.04
0.41
1.04
0.41
1.04
0.41
0.41
0.71
0.81
0.41
-

FACTOR
DE
DEMANDA

0.6
0.8
0.6
0.8

0.6
0.8
0.6
0.8
0.6
0.8
0.6
0.8
0.6
0.8
0.6
0.8
0.6
0.8
0.6
0.8
0.6
0.8
0.6
0.8
0.6
0.8
0.6
0.8
0.6
0.8
0.6
0.8
0.6
0.8
0.6
0.8
0.6
0.8
0.6
0.8
0.6
0.8

1.25
1
1.25
1
1.25
0.6
-

2250 W

CARGA
DEMANDADA

672 W
2250 W
672 W
2250 W
672 W
2250 W
672 W
2250 W
672 W
2250 W
672 W
2250 W
672 W
2250 W
672 W
2250 W
672 W
2250 W
672 W
2250 W
672 W
2250 W
672 W
2250 W
672 W
2250 W
672 W
2250 W
672 W
2250 W
672 W
2250 W
672 W
2250 W
672 W
2250 W
672 W
2250 W
672 W
2250 W

672 W
536.25 W
230 W
278.75W
324 W

APAGADOR DOS VIAS

CONTACTO DPLEX POLARIZADO A


TIERRA
LUMINARIA DE CENTRO

LUMINARIA ARBOTANTE
CANALIZACION POR PISO

CANALIZACIN POR LOZA O MURO

CENTRO DE CARGA

KILOWATTORIMETRO

INTERRUPTOR TERMOMAGNTICO
CONEXION A TIERRA FISICA
ACOMETIDA ELECTRICA
CANALIZACIN QUE BAJA

CANALIZACIN QUE SUBE


REGISTRO ELCTRICO DE 40cm X 60cm
BOMBA HIDRULICA

2-14
1-14d
T-13mm

C-38

2-14
1-14d
T-13mm

C-38

C-45

2-14
1-14d
T-13mm

C-38
2-14
1-14d
T-13mm
2-14
1-14d
T-13mm

2-14
1-14d
T-13mm

C-38

C-38

C-37

4-14
1-14d
T-13mm

C-45

2-12
1-12d
T-13mm

2-14
1-14d
T-13mm

2-14
1-14d
T-13mm

3-14
1-14d
T-13mm

C-38

2-14
1-14d
T-13mm

C-38

2-12
C-37
2-14
1-12d
T-25mm
2-12
1-12d
T-13mm 2-12
1-12d
T-13mm

C-37

C-45

3-14
1-14d
T-13mm

C-40

C-40

2-14
1-14d
T-13mm

C-40

C-45

C-45

C-42

4-14
1-14d
T-13mm

C-41

2-12
1-12d
T-13mm

C-41

2-14
1-14d
T-13mm

C-42

3-14
1-14d
T-13mm

C-40

2-14
1-14d
T-13mm

C-40

3-14
1-14d
T-13mm

C-39
2-12
2-14
1-12d
T-25mm
2-12
1-12d
T-13mm
2-12
1-12d
T-13mm
C-39

C-40

2-14
1-14d
T-13mm

2-14
1-14d
T-13mm

2-14
1-14d
T-13mm

2-14
1-14d
T-13mm

2-14
1-14d
T-13mm

2-14
1-14d
T-13mm

C-40

C-39

2-12
1-12d
T-13mm

5-14
1-14d
T-13mm

2-14
1-14d
T-13mm

C-42

2-14
1-14d
T-13mm

C-42

2-14
1-14d
T-13mm

2-14
1-14d
T-13mm

2-12
1-12d
T-13mm

2-14
1-14d
T-13mm

2-14
1-14d
T-13mm

2-14
1-14d
T-13mm

C-42

2-12
2-14
1-12d
T-25mm

2-12
1-12d
T-13mm

2-14
1-14d
T-13mm

4-14
1-14d
T-13mm

C-45

C-42

C-41

También podría gustarte