CALCULO DE TUBERIAS DE DESCARGA AGUAS OSCURAS

PROFESIONAL:

PROYECTO:

TRAMO

UNIDADES DE
DESCARGA
(TABLA 40)

DIAMETRO ()
TABLA 42

PENDIENTE
(ART 330)

DIAMETRO
CORREGIDO () ART
335 Y 420

PENDIENTE
CORREGIDA

1.6
7.2
2.3
3.4
4.5
5.6
6.8
8.15
14.15
15.13
12.13
13.16
9.16
16.17
10.17
17.18
11.18
18.19
21.20
19.20
20.22
23.25
25.27
24.27
27.29
26.29
29.31
28.31
31.32
30.32

2
0
2
4+2=6
6+3=9
9+1=10
10+2=12
12
0
12
1
12+1=13
1
13+1=14
3
14+3=17
4
4+17=21
2
21
21+2=23
0
4
1
4+1=5
2
5+2=7
4
7+4=11
3

1 1/2"
0
1 1/2"
2"
2 1/2"
2 1/2"
2 1/2"
2 1/2"
0
2 1/2"
1 1/4"
3"
1 1/4"
3"
1 1/2"
3"
2"
3"
1 1/2"
3"
3"
0
2"
1 1/4"
2"
1 1/2"
2 1/2"
2"
2 1/2"
1 1/2"

2%
2%
2%
2%
2%
2%
2%
2%
2%
2%
2%
2%
2%
2%
2%
2%
2%
2%
2%
2%
2%
2%
2%
2%
2%
2%
2%
2%
2%
2%

2"
4"
4"
4"
4"
4"
4"
4"
4"
4"
2"
4"
2"
4"
4"
4"
4"
4"
2"
4"
4"
4"
4"
2"
2"
2"
4"
4"
4"
2"

2%
1%
1%
1%
1%
1%
1%
1%
1%
1%
2%
1%
2%
1%
1%
1%
1%
1%
2%
1%
1%
1%
1%
2%
2%
2%
1%
1%
1%
2%

32.34

11+3=14

3"

2%

4"

1%

33.34

1 1/2"

2%

4"

1%

34.37

14+3=17

3"

2%

4"

1%

35.37
37.38

1
17+1=18

1 1/4"
3"

2%
2%

2"
4"

2%
1%

36.38

1 1/4"

2%

2"

2%

38.22

18+1=19

3"

2%

4"

1%

22.T

19+23=42

4"

2%

4"

1%

NOTAS:

ART. 329: VELOCIDAD DE


FLUJO MINIMA 0,6 M/
SEG

ART.
330:
LAS
PENDIENTES
SERAN
CONSTANTES EN CADA
TRAMO Y EN NINGUN
CASO MENOR DEL 1%
CUANDO EL DIAMETRO
SEA IGUAL O MENOR A 3"
LA PENDIENTE MINIMA
SERA DE 2%
LOS
CAMBIOS
DE
DIRECCION
EN
LOS
RAMALES HORIZONTALES
DEBERAN SER A 45
(ART. 358)

TAPON
DE
LIMPIEZA;
DEBE
COLOCARSE
AL
COMIENZO DE UN TRAMO
Y CADA DOS CAMBIOS DE
DIRECCION (ART. 419 Y
420) DEBEN SER DEL
MISMO DIAMETRO DE LA
TUBERIA A LA CUAL
SIRVEN Y NO MENOR DE
4"
EN
TUBERIAS
MAYORES