Está en la página 1de 2

GERENCIA REGIONAL MAGDALENA MEDIO

SUPERINTENDENCIA DE OPERACIONES DEL RO


COORDINACIN DE MANTENIMIENTO DE SUBSUELO
TUBERA UTILIZADA EN SUPERINTENDENCIA DEL RO.
TUBING

ROSCA

PESO (lb/ft)

GRADO

ID (in)

Drift (in)

OD Coupling
(in)

Capacidad
(Bbl/ft)

Presin
Estallido
(psi)

Presin
Colapso (psi)

Yield Strength
(lbs)

2 3/8"

eue

4.7

J-55

1.995

1.901

2.91

0.0039

7,700

7,180

71,730

2 3/8"

HY CS

4.7

N-80

1.995

1.901

2.91

0.0039

11,200

9,940

104,340

2 7/8"

eue

6.5

J-55

2.441

2.347

3 21/32"

0.00579

7,260

7,680

99,660

3 1/2"

eue

9.3

J-55

2.992

2.867

4 1/2"

0.0087

6,980

7,400

142,460

2 7/8" DP

IF

10.4

2.151

2.151

4 1/8"

0.00449

16,530

16,510

214,000

2 7/8"

H-90

6.5

N-80

2.441

2.151

4 1/8"

0.00579

10,570

11,160

105,570

1" (1,315")

HY CS

2.25

N-80

0.957

0.848

1,6"

0.00089

19,060

18,820

31,940

1 1/4" (1,680")

HY CS

2.4

N-80

1.38

1.286

1,88"

0.00185

11,810

12,360

44,370

5 1/2" RIII

FJ HY

17

------

4.892

4.767

------

0.0232

------

------

------

Yield
Strenght
(lbs)

Torque
Recomendado
(lb-ft)

1 1/2"
1 5/8"
1 5/8"
2"
2"
-----

36,000
49,000
----64,000
----76,000

460
735
1,000
1,100
---1,570

ID (in)

Drift (in)

6.366
6.366
6.184
8.835

6.241
6.241
6.059
8.678

VARILLA UTILIZADA EN SUPERINTENDENCIA DEL RO.


VARILLA

PESO (lb/ft)

GRADO

OD Shoulder
(in)

3/4"
7/8"
7/8"
1"
1"
1 1/8"

1.4
1.7
1.7
2.7
2.7
3.4

D
D
ELECTRA
D
ELECTRA
D

1 1/2"
1 5/8"
1 5/8"
2"
2"
2 1/4"

OD Coupling
OD Coupling
Slim Hole
Full Size (in)
(in)
1 1/2"
1 5/8"
1 5/8"
2"
2"
-----

CASING
CASING.

PESO (lb/ft)

GRADO

7"
7"
7"
9 5/8"

23
23
29
40

K-55
J-55
N-80
J-55

Capacidad
(Bbl/ft)
0.0393
0.0393
0.0371
0.0758

N SUPERINTENDENCIA DEL RO.


Torque
Recomendado (lbft)

1,650
2,280
3,500
3,500
400
-----2,300

25
3640
3315
5197.5
12152.5