Pruebas Motor Siemens

También podría gustarte

Está en la página 1de 2
SIEMENS [API STANDARD 641 rd EDITION ROUTINE TEST REPORT FOR INDUCTION MOTOR Taq. Wo. GA-2000N-E Order No: A18393-01 5 ‘Test Date: February 13, 2008 Purchasers Customer: Siemens Mexico Order No. Nameplate Data HP: 1600 Type: AZ Service Amperss: 183, Frame: 6813 Factor: 19 RPM: 1191 Volts: 4160 Class Insui: F Duy: Cont Herz: 60 KVA Code: F Amb. Temp: 40°C Phase; 3 Nema Design: - Test Characteristics ‘Stator Winding Resistance: “Temperature Resistance °C. Ohms. w 0.1832 Locked Rotor Test: Phase _Volts_Hertz 6 KW, 32082 «80 ~—«724 287.8 No-Load Test: Speed gem Volts Hertz Amps KW 200 416060 36274 High-Potential Test Volts 9,820 for 60 seconds Data from test on this motor, Issued ByA March 28, 2008 Siemens Energy & Automation, Inc. Power Conesian Deo sean Forest Avenue Tot rayeatst00 Nonead, OM aazr2386 chrLUOR Rea, 5-080 P2-USPAIR. B61 GA2000N AIBICIDIE Siemens Energy & Automation, Inc. Power Conversion DWision Report of Test for Induction Motor Date of Test: February 13, 2008 Order Number, A1833-01-5 Tog to. G A- 20008" Customer; Siemens Mexico NO LOAD BEARING TEMPERATURE TEST: Time of Test 3.50-hours Air Intake Temperature: 27.400 0.D.E, Bearing Total Temperature: 36.796. DLE, Bearing Total Temperature: 37.8°C. NO LOAD VIBRATION LEVELS? ‘ VeLociry INCH PER SECOND: ‘Opposite Drive End Drive End HOUSING: Vertical 08d 0.014 Horizontal 0.013 0.018, Axial 0.013 0.012 AMPLITUDE - MILS PEAK-TO-PEAK: ‘Opposite Drive End «SHAFT: Vertical = Horizontal = Vibration readings — unfittered Shaft rotation -CCW Motor Speed ~ 1200 RPM P2.uc-p-B-12-0601 Po. uStPABIe 08: (GA-2000N ABICIDIE