Está en la página 1de 1

INFORME DE LA EXAMINACION CON LIQUIDOS PENETRANTES

(LIQUID PENETRANT EXAMINATION INFORM)


INFORME :

FECHA DE EXAMINACION :

(INFORM)

MARCH 08, 2010

(EXAMINATION DATE)

HOJA:

(PAGE)

1 OF 2

CLIENTE:
(CUSTOMER)

IDENTIFICACION ITEM :
(ITEM IDENTIFICATION)

FEED DIFFUSER 2nd STAGE REACTOR COLUMN: 20-R-103 DRAWING No. 7113282-01
SHEET 01 ITEM-001
ASTM A 240 Tp 304L

MATERIAL ITEM:
(ITEM MATERIAL )

ESTANDAR DE ACEPTACION :

ASME SECC VIII-1

(ACCEPTANCE STANDARD)

PT-01 REV. 06

PROCEDIMIENTO Y REVISION :
(PROCEDURE AND REVISION)

4,7 - 6,4 mm

ESPESOR DEL ITEM:


(ITEM THICKNESS)

TIPO DE LIQUIDO PENETRANTE:

VISIBLE

(LIQUID PENETRANT TYPE)

(VISIBLE)

OK

FLUORESCENTES
(FLUORESCENT)

DESIGNACION DE MATERIALES
(MATERIALS DESIGNATION)

PENETRANTE :

REMOVEDOR :

(PENETRANT)
TIPO :
SKL-SP1
(TYPE)
EQUIPO DE ILUMINACION:
(LIGHTING EQUIPMENT)

REVELADOR :

(REMOVER)
TIPO :
(TYPE)

(DEVELOPER)
TIPO :
SKD-S2
(TYPE)

THINNER

DAY LIGHT 3 000 LUX

RESULTADO DE LA INSPECCION
(INSPECTION RESULT )

ITEMS INSPECCIONADOS

INDICACIONES

EVALUACION

(INSPECTED ITEMS)

(INDICATIONS)

(EVALUATION)

GUIDE No. 1

NO INDICATIONS

ACCEPTED

GUIDE No. 2

NO INDICATIONS

ACCEPTED

GUIDE No. 3

NO INDICATIONS

ACCEPTED

GUIDE No. 4

NO INDICATIONS

ACCEPTED

SUPPORT BAR No. 1

NO INDICATIONS

ACCEPTED

SUPPORT BAR No. 2

NO INDICATIONS

ACCEPTED

SUPPORT BAR No. 3

NO INDICATIONS

ACCEPTED

SUPPORT BAR No. 4

NO INDICATIONS

ACCEPTED

SUPPORT BAR No. 5

NO INDICATIONS

ACCEPTED

SUPPORT BAR No. 6

NO INDICATIONS

ACCEPTED

MAPEO O REGISTRO DE LAS INDICACIONES :


(MAP OR RECORD OF INDICATIONS)

OBSERVACIONES:
(REMARKS)

LENGHT EXAMINED : 2,840 mm


ATTACHED SCKETCH

EXAMINADO POR :

NIVEL :

(EXAMINED BY)

(LEVEL)

Alcance de la acreditacion: ASME V ARTICLE 2, ASTM E-8 Y ASTM E-797

II

También podría gustarte