Está en la página 1de 1

Page 1

In-Line Valve Co Choke Sizing Program

26 January 2015

Customer: Petrofac
Enquiry Number:
Quote Number: 1
FileName: XCV-381.ilv

Fluid Type: HC Mixture


Project Name:
Tag Number: XCV-381

Case
Input:
Service
Temperature
Inlet Pressure
Outlet Pressure
Vapor Pressure
Liquid #1 Flow Rate
Liquid #1 Density
Liquid #2 Flow Rate
Liquid #2 Density
Gas Flow Rate
Gas Density
Isentropic Ratio (K)
Compressibility (Z)
Nom Outlet Pipe Size
Outlet Pipe Schedule

Deg C
Barg
Barg
Barg
Kg/hr
Kg/m3
Kg/hr
Kg/m3
Kg/hr
MW
-

Total Flow
kg/hr
Gas Threshold
Barg
Liquid Threshold
Barg
Gas Expansion Factor (Y)
Results:
Calculated Cv
Cv
Valve Size & Type
Nominal
Selected Trim Size
Bean
Selected Trim Max Cv
Cv
Flow Percent Open
Percent
Total Noise
dBA at 1M
Power Loss
kW/Bean

Case

Case

Maximum
35
103.421
58.971
103.45
5074
965
0
1100
742
18.59
1.71
0.789
3
XXS

Normal
35
103.421
58.971
103.45
4290
952.3
0
1100
773.1
18.52
1.708
0.791
3
XXS

Minimum
35
103.421
58.971
103.45
3290
874.5
0
1100
912.1
18.28
1.699
0.797
3
XXS

5816.00
7.75
97.31
0.85

5063.10
7.86
97.42
0.84

4202.10
8.37
98.08
0.84

1.68
20PC
32
5.9
42%
26
0.34

1.56
20PC
32
5.9
40%
25
0.32

1.49
20PC
32
5.9
40%
24
0.32

Sizing Notes:
1) Where Process Data is not given, and where appropriate, typical values are
entered
2) Select Bean Size based on the maximum Cv condition for the valve.
3) Calculations are based on ANSI/ISA S75.01-1985
4) The entered value for Outlet Pressure must not be less than the gas and
liquid threshold values for accurate Cv calculation.
5) Where Power Loss / Bean exceeds 1 Kw, increased trim erosion, noise or
vibration may result. Consult In-Line Valve for advice