This chapter describes the process of configuring Ethernet private line (EPL) and Ethernet
private local area network (EPLn) services on the T2000, and related engineering
requirements and engineering information as well.
The configuration of Ethernet virtual private line (EVPL) and Ethernet virtual private local
area network (EVPLn) will be described with resilient packet ring (RPR) in Chapter 4.
Through this example, you can learn how to configure EPL and other similar services.
The following table is a mapping table which associates the Ethernet services to the Ethernet
boards of the OptiX OSN 3500/2500/1500.
In this chapter, the OptiX OSN 3500 product is taken as an example. For the OptiX OSN 2500 and the
OptiX OSN 1500A/B, service configuration is performed in the same way. The only difference is that
the boards of the OptiX OSN 2500 and the OptiX OSN 1500A/B are inserted in different slots.
Title Description
3.1 Configuring the Point-to-Point Describes how to configure the point-to-point EPL
EPL Service services on the T2000
3.2 Configuring the PORT Shared Describes how to configure the port shared EPL
EPL Service services on the T2000
3.3 Configuring the VCTRUNK Describes how to configure the VCTRUNK shared
Shared EPL Service EPL services on the T2000
3.4 Configuring the EPLn Service Describes how to configure the EPLn services on the
T2000
Networking Diagram
Figure 3-1 shows the Ethernet service networking and port allocation.
A B
PORT1 PORT2
T2000
PORT1 PORT2
NE3
A B
VC-Trunk
S S S S S S S S S S S S S S S S S S S
1 2 2 2 2 2 2 2 2 2 2 3 3 3 3 3 3 3 3
9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7
D75S
D75S
D75S
D75S
D75S
D75S
PIU
PIU
AUX
S S S S S S S S S S S S S S S S S S
1 2 3 4 5 6 7 8 9 1 1 1 1 1 1 1 1 1
0 1 2 3 4 5 6 7 8
GXCSA
GXCSA
N1EFS4
PQ1
PQ1
GSCC
GSCC
PQ1
PQ1
SL16
SL16
S S S S S S S S S S S S S S S S S S S
1 2 2 2 2 2 2 2 2 2 2 3 3 3 3 3 3 3 3
9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7
D75S
D75S
C34S
PIU
PIU
AUX
FAN FAN FAN
S S S S S S S S S S S S S S S S S S
1 2 3 4 5 6 7 8 9 1 1 1 1 1 1 1 1 1
0 1 2 3 4 5 6 7 8
N1EFS4
GXCSA
GXCSA
GSCC
GSCC
PQ1
SL4
PL3
PORT1 PORT1
A A
10M VCTRUNK1 SDH VCTRUNK1 10M
VC4-4:VC12-1~VC12-5 VC4-4:VC12-1~VC12-5
PORT2 PORT2
B B
VCTRUNK2 VCTRUNK2
40M VC4-1:VC-3-1
40M
VC4-1:VC-3-1
NE1
NE5
Only VC4-4 can be used when the N2EFS0 and N1EFS4 boards are bounded with a path at VC-12 level.
Service A B
Attribute
Ring
Station NE1 NE2 NE3 NE4 NE1
Timeslot 12-SL16-1 7-SL16-1 12-SL16-1 7-SL16-1 12-SL16-1 7-SL16-1 12-SL16-1 7-SL16-1
VC-12: 1-5
VC4-3
13-EFS4: VC4-4
VC-3: 1
VC4-4
13-EFS4: VC4-1
Chain
Station NE4 NE5
Timeslot 13-SL4-1 7-SL4-1
VC-12: 1-5
VC4-3
15-EFS4: VC4-4
VC-3: 1
VC4-4
15-EFS4: VC4-1
Forward
Add/Drop
1 Creating a board
2 Configuring Ethernet interfaces
3 Configuring bound paths
4 Creating the point-to-point EPL service
5 Configuring committed access rate (CAR) Optional
6 Configuring the cross-connect from Ethernet boards to SDH
line boards
Creating a Board
Follow the steps below to create a board.
Step 1 In the Main Topology, double click the NE1 icon to open the NE panel.
Step 2 Right click slot 13 according to the board layout shown in Figure 3-2, and select N1EFS4
from the shortcut menu.
Step 3 Make sure that the N1EFS4 board has been configured in slot 13 and click .
Step 4 Repeat steps 1–3 to create the Ethernet board of NE5. Figure 3-3 shows the board layout of
NE5.
----End
See the T2000 online help for the meaning of each parameter during service configuration.
4. Select the Tag Attribute tab. Set the TAG of the PORT1 and PORT2 to Access. Other
items adopt the default value. Click Apply.
4. To set a bound path for VCTRUNK2, set as follows in the dialog box.
− Configurable Ports: VCTRUNK2
− Level: VC3-xv
− Direction: Bidirectional
− Available Resources: VC4-1
− Select VC3-1 from the Available Timeslots, and then click .
− Click OK.
4. Repeat 3 to create the EPL service for B. Set as follows in the dialog box.
− Service Type: EPL
− Service Direction: Bidirectional
− Source Port: PORT2
− Sink Port: VCTRUNK2
− Click OK.
Step 4 Configuring CAR (optional)
1. Select 13-N1EFS4 from the Object Tree and select Configuration > QoS
Management > Flow Management from the Function Tree, and then the CAR tab.
2. Click New, and the Create CAR dialog box is displayed.
3. Set as follows in the dialog box.
− CAR ID: 1
− Enabled/Disabled: Enabled
− Committed Information Rate(kbit/s): 10 Mbit/s
− Committed Burst Size(kbyte): 0
− Peak Information Rate(kbit/s): 20 Mbit/s
Step 5 Configuring the cross-connect from Ethernet boards to SDH line boards
The data configuration of NE5 is the same as that of NE1, except that some parameters are different.
1. Click the NE switching shortcut icon . Select NE5, and click OK.
2. Select 15-N1EFS4 from the Object Tree and select Configuration > Ethernet
Interface Management > Ethernet Interface from the Function Tree. Then, click
.
3. Select External Port, and set as follows.
− Select the Basic Attributes tab. Set the Enabled/Disabled of the PORT1 and PORT2
to Enabled. Click Apply.
− Select the TAG Attribute tab. Set the TAG of the PORT1 and PORT2 to Access.
− Other items adopt the default value. Click Apply.
Step 2 Configuring bound paths
1. Select the Bound Path tab from the Internal Port page.
2. Click Configuration, and the Bound Path Configuration dialog box is displayed.
3. To set bound paths for VCTRUNK1, set as follows in the dialog box.
− Configurable Ports: VCTRUNK1
− Level: VC12-xv
− Direction: Bidirectional
− Available Resources: VC4-4
− Select VC12-1 to VC12-5 from the Available Timeslots one by one, and then click
.
4. To set a bound path for VCTRUNK2, set as follows in the dialog box.
− Configurable Ports: VCTRUNK2
− Level: VC3-xv
− Direction: Bidirectional
− Available Resources: VC4-1
− Select VC3-1 from the Available Timeslots, and then click .
− Click OK.
Step 3 Creating the point-to-point EPL service
1. Select Configuration > Ethernet Service > Ethernet Line Service from the Function
Tree.
2. Click New and the Create Ethernet Line Service dialog box is displayed.
3. According to Figure 3-4 set as follows to create the EPL service for A.
− Service Type: EPL
− Service Direction: Bidirectional
− Source Port: PORT1
− Sink Port: VCTRUNK1
− Click Apply.
4. Repeat 3 to create the EPL service for B. Set as follows in the dialog box.
− Service Type: EPL
− Service Direction: Bidirectional
− Source Port: PORT2
− Sink Port: VCTRUNK2
− Click OK.
Step 4 Configuring CAR (optional)
1. Select Configuration > QoS Management > Flow Management from the Function
Tree and select the CAR tab.
2. Click New and the Create CAR dialog box is displayed.
3. Set as follows in the dialog box.
− CAR ID: 1
− Enabled/Disabled: Enabled
− Committed Information Rate(kbit/s): 10 Mbit/s
− Committed Burst Size(kbyte): 0
− Peak Information Rate(kbit/s): 20 Mbit/s
− Maximum Burst Size(kbyte): 0
− Click Apply.
4. Repeat 3 to set as follows in the dialog box.
− CAR ID: 2
− Enabled/Disabled: Enabled
− Committed Information Rate(kbit/s): 40 Mbit/s
− Committed Burst Size(kbyte): 0
− Peak Information Rate(kbit/s): 50 Mbit/s
− Maximum Burst Size(kbyte): 0
− Click OK.
5. Select the Flow tab.
6. Set the bound CAR for PORT1 and VCTRUNK1.
− Bound CAR: 1
− Click Apply.
7. Repeat 6 to set the bound CAR for PORT 2 and VCTRUNK2.
− Bound CAR: 2
− Click Apply.
Step 5 Configuring the cross-connect from Ethernet boards to SDH line boards
1. Select NE5 from the Object Tree.
2. Select Configuration > SDH Service Configuration from the Function Tree.
3. Click Create, and the Create SDH Service dialog box is displayed.
4. Set as follows in the dialog box.
− Level: VC12
− Direction: Bidirectional
− Source Slot: 15-N1EFS4-1(SDH-1)
− Source VC4: VC4-4
− Source Timeslot Range(e.g.1,3-6): 1–5
− Sink Slot: 7-N2SL4-1(SDH-1)
− Sink VC4: VC4-3
− Sink Timeslot Range(e.g.1,3-6): 1–5
− Activate Immediately: Yes
− Click Apply.
5. Repeat 4 to set as follows in the dialog box.
− Level: VC3
− Direction: Bidirectional
− Source Slot: 15-N1EFS4-1(SDH-1)
− Source VC4: VC4-1
− Source Timeslot Range(e.g.1,3-6): 1
− Sink Slot: 7-N2SL4-1(SDH-1)
− Sink VC4: VC4-4
− Sink Timeslot Range(e.g.1,3-6): 1
− Activate Immediately: Yes
− Click Apply.
----End
Step 1 Click the NE switching shortcut icon . Select NE4, and click OK.
Step 2 Select Configuration > SDH Service Configuration from the Function Tree.
Step 3 Click Create, and the Create SDH Service dialog box is displayed.
Step 4 Set as follows in the dialog box.
z Level: VC12
z Direction: Bidirectional
z Source Slot: 12-N2SL16-1(SDH-1)
z Source VC4: VC4-3
Ethernet service can be created by trail or by station. If you purchase the license with trail management
function, you can create Ethernet service by trail; otherwise, you can only create Ethernet service by
station.
Table 3-5 shows the process of creating point-to-point EPL service on the T2000.
Step 4 Select the N1EFS4 board, then select VCTRUNK port 1 and select
VC4:4-VC12:1–VC4:4-VC12:5 for available timeslot. Click OK.
Step 5 Click Browse. Select the sink NE (NE5). Select the N1EFS4 board, and select N1EFS4, then
select VCTRUNK port 1 and VC4:4-VC12:1–VC4:4-VC12:5 for Available Timeslot. Click
OK.
Step 6 Select the Activate check box, and leave default setting for others.
Step 7 Click Apply to create the trunk link from NE1 to NE5 of user A.
Step 8 Repeat 2–7 to create the trunk link from NE1 to NE5 of user B.
----End
----End
Networking Diagram
Figure 3-6shows the Ethernet service networking and port allocation.
C (Headquarters)
PORT3
NE1
T2000
PORT3 PORT4
A B
NE2 NE4 NE5
PORT1 PORT2
NE3
A B
VC-Trunk
PORT1 PORT1
A A
10M VCTRUNK1 VCTRUNK1 10M
VC4-4:VC12-1~VC12-5 VC4-4:VC12-1~VC12-5
PORT2 PORT2
B B
VCTRUNK2 VCTRUNK2
40M SDH VC4-1:VC-3-1
40M
VC4-1:VC-3-1
PORT3
C1
PORT3 VCTRUNK3 VCTRUNK3 10M
C VC4-4:VC12-6~VC12-10 VC4-4:VC12-6~VC12-10
PORT4
C2
VCTRUNK4 VCTRUNK4
VC4-4:VC12-11~VC12-15 VC4-4:VC12-11~VC12-15
10M
NE1 NE5
Service C
Attribute
Source NE NE1
Source board - port 13-N1EFS4-3
Source Timeslot range VC4-4: VC12-6–VC12-10 VC4-4:
VC12-11–VC12-15
Source VCTRUNK VCTRUNK3 VCTRUNK4
Working mode of source Auto negotiation Auto negotiation
PORT
TAG flag of source PORT Tag aware Tag aware
Source VLAN ID 3 4
Bound bandwidth 5 x VC12 5 x VC12
Sink NE NE5
Sink board - port 15-N1EFS4-3 15-N1EFS4-4
Sink Timeslot range VC4-4: VC12-6–VC12-10 VC4-4:
VC12-11–VC12-15
Sink VCTRUNK VCTRUNK3 VCTRUNK4
Working mode of sink PORT Auto negotiation Auto negotiation
TAG flag of sink PORT Access Access
Sink VLAN ID 3 4
Chain
Station NE4 NE5
Timeslot 13-SL4-1 7-SL4-1
VC-12: 6-15
VC4-3
15-EFS4: VC4-4
Forwared
Add/Drop
The configuration of the PORT shared EPL service is the same as that of the point-to-point EPL service,
except that the Ethernet service configuration on NE1 and interface attributes are different.
− Select the Basic Attributes tab. Set the Enabled/Disabled of the PORT3 to Enabled.
Click Apply.
− Select the TAG Attribute tab. Set the TAG of the PORT3 to Tag Aware.
− Other items adopt the default value. Click Apply.
Step 2 Configuring bound paths
1. Select the Bound Path tab from the Internal Port page.
2. Click Configuration, and the Bound Path Configuration dialog box is displayed.
3. To set bound paths for VCTRUNK3, set as follows in the dialog box.
− Configurable Ports: VCTRUNK3
− Level: VC12-xv
− Direction: Bidirectional
− Available Resources: VC4-4
− Select VC12-6 to VC12-10 from the Available Timeslots one by one, and then click
.
4. To set bound paths for VCTRUNK4, set as follows in the dialog box.
− Configurable Ports: VCTRUNK4
− Level: VC12-xv
− Direction: Bidirectional
− Available Resources: VC4-4
− Select VC12-11 to VC12-15 from the Available Timeslots one by one, and then click
.
− Click OK.
Step 3 Creating the PORT shared EPL service
1. Select Configuration > Ethernet Service > Ethernet Line Service from the Function
Tree.
2. Click New and the Create Ethernet Line Service dialog box is displayed.
3. According to Figure 3-7, set as follows to create the service from C to C1.
− Service Type: EPL
− Service Direction: Bidirectional
− Source Port: PORT3
− Source VLAN: 3
− Sink Port: VCTRUNK3
− Sink VLAN: 3
− Click Apply.
4. Repeat 3 to create the service from C to C2. Set as follows in the dialog box.
− Service Type: EPL
− Service Direction: Bidirectional
− Source Port: PORT3
− Source VLAN: 4
− Sink Port: VCTRUNK4
− Sink VLAN: 4
− Click OK.
Step 4 Configuring the cross-connect from Ethernet boards to SDH line boards
1. Select NE1 from the Object Tree.
2. Select Configuration > SDH Service Configuration from the Function Tree.
3. Click Create, and the Create SDH Service dialog box is displayed.
4. Set as follows in the dialog box.
− Level: VC12
− Direction: Bidirectional
− Source Slot: 13-N1EFS4-1(SDH-1)
− Source VC4: VC4-4
− Source Timeslot Range(e.g.1,3-6): 6–15
− Sink Slot: 7-N2SL16-1(SDH-1)
− Sink VC4: VC4-3
− Sink Timeslot Range(e.g.1,3-6): 6–15
− Activate Immediately: Yes
− Click OK.
----End
The data configuration of NE5 is performed in the similar way, except that some parameters are
different.
1. Click the NE switching shortcut icon . Select NE5, and click OK.
2. Select 15-N1EFS4 from the Object Tree and Configuration > Ethernet Interface
Management > Ethernet Interface from the Function Tree, and then click .
3. Select External Port, and set as follows.
− Select the Basic Attributes tab. Set the Enabled/Disabled of the PORT3 and PORT4
to Enabled. Click Apply.
− Select the TAG Attribute tab. Set the TAG of the PORT3 and PORT4 to Access. Set
the Default VLAN ID of the PORT3 to 3. Set the Default VLAN ID of the PORT4
to 4.
− Other items adopt the default value. Click Apply.
Step 2 Configuring bound paths
1. Select the Bound Path tab from the Internal Port page.
2. Click Configuration, and the Bound Path Configuration dialog box is displayed.
3. To set bound paths for VCTRUNK3, set as follows in the dialog box.
− Configurable Ports: VCTRUNK3
− Level: VC12-xv
− Direction: Bidirectional
− Available Resources: VC4-4
− Select VC12-6 to VC12-10 from the Available Timeslots one by one, and then click
.
4. To set bound paths for VCTRUNK4, set as follows in the dialog box.
− Configurable Ports: VCTRUNK4
− Level: VC12-xv
− Direction: Bidirectional
− Available Resources: VC4-4
− Select VC12-11 to VC12-15 from the Available Timeslots one by one, and then click
.
− Click OK.
Step 3 Creating the PORT shared EPL service
1. Select Configuration > Ethernet Service > Ethernet Line Service from the Function
Tree.
2. Click New, and the Create Ethernet Line Service dialog box is displayed.
3. According to Figure 3-7, set as follows to create the service from C1 to C.
− Service Type: EPL
− Service Direction: Bidirectional
− Source Port: PORT3
− Source VLAN: 3
− Sink Port: VCTRUNK3
− Sink VLAN: 3
− Click Apply.
4. Repeat 3 to create the service from C2 to C. Set as follows in the dialog box.
− Service Type: EPL
− Service Direction: Bidirectional
− Source Port: PORT4
− Source VLAN: 4
− Sink Port: VCTRUNK4
− Sink VLAN: 4
− Click OK.
Step 4 Configuring the cross-connect from Ethernet boards to SDH line boards
1. Select NE5 from the Object Tree.
2. Select Configuration > SDH Service Configuration from the Function Tree.
3. Click Create, and the Create SDH Service dialog box is displayed.
4. Set as follows in the dialog box.
− Level: VC12
− Direction: Bidirectional
− Source Slot: 15-N1EFS4-1(SDH-1)
− Source VC4: VC4-4
− Source Timeslot Range(e.g.1,3-6): 6-15
− Sink Slot: 7-N2SL4-1(SDH-1)
− Sink VC4: VC4-3
− Sink Timeslot Range(e.g.1,3-6): 6-15
− Activate Immediately: Yes
− Click OK.
----End
Step 1 Click the NE switching shortcut icon . Select NE4, and click OK.
Step 2 Select Configuration > SDH Service Configuration from the Function Tree.
Step 3 Click Create, and the Create SDH Service dialog box is displayed.
Step 4 Set as follows in the dialog box.
z Level: VC12
z Direction: Bidirectional
z Source Slot: 12-N2SL16-1(SDH-1)
Ethernet service can be created by trail or by station. If you purchase the license with trail management
function, you can create Ethernet service by trail; otherwise, you can only create Ethernet service by
station.
Table 3-8 shows main procedures of creating PORT shared EPL service on the T2000.
Step 7 Click Apply to create the trunk link from C of NE1 to C1 of NE5.
Step 8 Repeat steps 2–7 to create the trunk link from C of NE1 to C2 of NE5.
----End
z VLAN ID: 3
z Set sink parameters.
z Port Usage Strategy: Port+VLAN
Step 3 Click Browse and select a proper sink line port: NE5-15-N1EFS4-PORT3
z VLAN ID: 3.
z Trunk Link Route Strategy: Use Existing Trunk Links.
z Select Trunk_Link-0003 with bandwidth being 5 x VC12.
z Click Next.
Step 4 Set port attributes in the pop-up interface.
z For PORT3 of NE1:
z TAG: Tag Aware
z Enable Port: Enable
z For PORT3 of NE5:
z TAG: Access
z Enable Port: Enable
z Select the Activate check box.
z Click Finish.
Step 5 Repeat steps 1–4 to create an EPL trail from C of NE1 to C2 of NE5.
----End
Networking Diagram
Figure 3-9 shows the Ethernet service networking and port allocation.
NE1
T2000
PORT1
D
NE2 B
NE4
E NE5
PORT2
NE3
PORT1 PORT2
VC-Trunk
D’ E’
S S S S S S S S S S S S S S S S S S S
1 2 2 2 2 2 2 2 2 2 2 3 3 3 3 3 3 3 3
9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7
D75S
D75S
PIU
PIU
AUX
FAN FAN FAN
S S S S S S S S S S S S S S S S S S
1 2 3 4 5 6 7 8 9 1 1 1 1 1 1 1 1 1
0 1 2 3 4 5 6 7 8
N2EGS2
GXCSA
GXCSA
GSCC
GSCC
SL16
SL16
PQ1
PORT1 PORT1
D D’
300M 300M
NE2 NE3
Service D E
Attribute
Source NE NE2
Source board - port 13-N2EGS2-1 13-N2EGS2-2
Source Timeslot range VC4-1: VC3-1 to VC3-3
VC4-2: VC3-1 to VC3-3
Source VCTRUNK VCTRUNK1
Working mode of source PORT 1000M full duplex 1000M full duplex
TAG flag of source PORT Access Access
VLAN ID of source PORT 1 2
Bound bandwidth 6 x VC-3
Sink NE NE3
Sink board - port 13-N2EGS2-1 13-N2EGS2-2
Sink Timeslot range VC4-1: VC3-1 to VC3-3
VC4-2: VC3-1 to VC3-3
Sink VCTRUNK VCTRUNK1
Working mode of sink PORT 1000M full duplex 1000M full duplex
TAG flag of sink PORT Access Access
VLAN ID of sink PORT 1 2
VC-3: 1-3
VC4-4
13-EGS2: VC4-2
Forward
Add/Drop
1 Creating a board
2 Configuring Ethernet interfaces
3 Configuring bound paths
4 Creating the VCTRUNK shared EPL service
5 Configuring CAR Optional.
6 Configuring the cross-connect from Ethernet
boards to SDH line boards
Creating a Board
Follow the steps below to create a board.
Step 1 In the Main Topology, double click the NE2 icon to open the NE panel.
Step 2 Right click slot 13 according to the board layout of NE1 shown in Figure 3-10, and select
N2EGS2.
Step 3 Make sure the N2EGS2 board is configured in slot 13, and click .
Step 4 Repeat steps 1–3 to create the Ethernet board of NE3. Figure 3-10 shows the board layout of
NE3.
----End
See theT2000 online help for the meaning of each parameter during service configuration.
1. Click the NE switching shortcut icon . Select NE3, and click OK.
2. Select 13-N2EGS2 from the Object Tree and Configuration > Ethernet Interface
Management > Ethernet Interface from the Function Tree, and then click .
3. Select External Port, and set as follows.
− Select the Basic Attributes tab. Set the Enabled/Disabled of the PORT1 and PORT2
to Enabled. Set the Working mode of the PORT1 and PORT2 to 1000M
Full-Duplex. Click Apply.
− Select the TAG Attribute tab. Set the TAG of the PORT1 and PORT2 to Access. Set
the Default VLAN ID of the PORT1 to 1. Set the Default VLAN ID of the PORT2
to 2.
− Other items adopt the default value. Click Apply.
Step 2 Configuring bound paths
1. Select the Bound Path tab from the Internal Port page.
2. Click Configuration, and the Bound Path Configuration dialog box is displayed.
3. To set bound paths for VCTRUNK1, set as follows in the dialog box.
− Configurable Ports: VCTRUNK1
− Level: VC3-xv
− Direction: Bidirectional
− Available Resources: VC4-1
− Select VC3-1 to VC3-3 from the Available Timeslots, and then click .
− Available Resources: VC4-2
− Select VC3-1 to VC3-3 from the Available Timeslots, and then click .
− Click OK.
Step 3 Creating the VCTRUNK shared EPL service
1. Select Configuration > Ethernet Service > Ethernet Line Service from the Function
Tree.
2. Click New, and the Create Ethernet Line Service dialog box is displayed.
3. According to Figure 3-11, set as follows to create the EPL service for D.
− Service Type: EPL
− Service Direction: Bidirectional
− Source Port: PORT1
− Source VLAN: 1
− Sink Port: VCTRUNK1
− Sink VLAN: 1
− Click Apply.
4. Repeat 3 to create the EPL service for E. Set as follows in the dialog box.
Ethernet service can be created by trail or by station. If you purchase the license with trail management
function, you can create Ethernet service by trail; otherwise, you can only create Ethernet service by
station.
Table 3-11 shows the process of creating VCTRUNK shared EPL service on the T2000.
Step 5 Click Browse. Select the sink NE (NE3). In the pop-up interface, select N2EGS2,
VCTRUNK port 1, 1 and 2 for Higher Order, and VC4:1-VC3:1–VC4:1-VC3:3 and
VC4:2-VC3:1–VC4:2-VC3:3 for available timeslot.
Step 6 Select the Activate check box, and leave the default setting for others.
Step 7 Click Apply to create the trunk link from NE2 to NE3 shared by users D, D', E, and E'.
----End
Step 5 Click Finish to create the EPL trail from D of NE2 to D' of NE3.
Step 6 Repeat steps 1–5 to create an EPL trail from E of NE2 to E' of NE3.
----End
Networking Diagram
Figure 3-13 shows the Ethernet service networking and port allocation.
NE1
T2000
VCTRUNK1 VB
PORT1
VB VCTRUNK1
NE2
PORT1
B
NE4
PORT1 PORT1
NE5
NE3
F1 F3
PORT1 VCTRUNK
VCTRUNK1 VB VCTRUNK2
F2 PORT1
S S S S S S S S S S S S S S S S S S S
1 2 2 2 2 2 2 2 2 2 2 3 3 3 3 3 3 3 3
9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7
ETF8
D75S
D75S
AUX
PIU
PIU
FAN FAN FAN
S S S S S S S S S S S S S S S S S S
1 2 3 4 5 6 7 8 9 1 1 1 1 1 1 1 1 1
0 1 2 3 4 5 6 7 8
N2EGS2
N2EFS0
GXCSA
GXCSA
GSCC
GSCC
SL16
SL16
PQ1
S S S S S S S S S S S S S S S S S S S
1 2 2 2 2 2 2 2 2 2 2 3 3 3 3 3 3 3 3
9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7
D75S
D75S
D75S
D75S
ETF8
C34S
PIU
PIU
AUX
S S S S S S S S S S S S S S S S S S
1 2 3 4 5 6 7 8 9 1 1 1 1 1 1 1 1 1
0 1 2 3 4 5 6 7 8
N2EFS0
GXCSA
GXCSA
GSCC
PQ1
PQ1
SL16
SL16
GSCC
SL4
PL3
VCTRUNK PORT
VC4-4:VC12-1~VC12-5
VB1
LP2
PORT1 LP1 VCTRUNK1 NE2
F2 VC4-4:VC12-1~VC12-5
10M LP3
SDH VC4-4:VC12-1~VC12-5
VB1
NE4
Source NE NE3
Source board - port 14-N2EFS0-1
Source Timeslot range VC4-4: VC12-1–VC12-5 VC4-4:
VC12-6–VC12-10
Source VCTRUNK VCTRUNK1 VCTRUNK2
Source VCTRUNK attribute PE PE
Working mode of source PORT Auto negotiation
TAG flag of source PORT Access
VLAN ID of source PORT 11 (Set as the user's demand)
VB VB1
Attached port PORT1, VCTRUNK1, VCTRUNK2
Sink NE NE2 NE4
Sink board - port 14-N2EFS0-1 15-N2EFS0-1
Sink Timeslot range VC4-4: VC12-1–VC12-5 VC4-4: VC12-1–VC12-5
Sink VCTRUNK VCTRUNK1 VCTRUNK1
Sink VCTRUNK attribute PE PE
Working mode of sink PORT Auto negotiation Auto negotiation
Service F
Attribute
Table 3-13 shows the forwarding filter table of NE2, NE3 and NE4.
Forward
Add/Drop
1 Creating a board
2 Configuring Ethernet interfaces
3 Configuring bound paths
4 Creating the EPLn service
5 Configuring the VLAN forwarding filter table
6 Configuring CAR Optional, see 3.1.3
7 Configuring the cross-connect from Ethernet
boards to SDH line boards
Creating a Board
Step 1 In the Main Topology, double click the NE2 icon to open the NE panel.
Step 2 Right click slot 14 according to Figure 3-14, and then select N2EFS0. Right click slot 31, and
then select ETF8.
Step 3 Make sure the N2EFS0 and ETF8 boards are configured in slots 14 and 31, and then click
Close.
Step 4 Repeat steps 1–3 to create the Ethernet board for NE3 and NE4. Figure 3-14 and Figure 3-15
show the board layout of NE3 and NE4 respectively.
----End
See the NM online help for the meaning of each parameter during service configuration.
3. To set bound paths for VCTRUNK1, set as follows in the dialog box.
− Configurable Ports: VCTRUNK1
− Level: VC12-xv
− Direction: Bidirectional
− Available Resources: VC4-4
− Select VC12-1 to VC12-5 from the Available Timeslots, and then click .
− Click OK.
1. Select Configuration > Ethernet Service > Ethernet LAN Service from the Function
Tree. Select VLAN tab.
2. Click New and the Create VLAN dialog box is displayed.
3. Set as following in the dialog box.
− VB: 1-VB1
− VLAN ID: 11
− Selected forwarding ports: PORT1 and VCTRUNK1
− Click OK.
Step 5 Configuring the cross-connect from Ethernet boards to SDH line boards
1. Select NE2 from the Object Tree.
2. Select Configuration > SDH Service Configuration from the Function Tree.
3. Click Create and the Create SDH Service dialog box is displayed.
4. Set as follows in the dialog box.
− Level: VC12
− Direction: Bidirectional
− Source Slot: 14-N2EFS0-1(SDH-1)
− Source VC4: VC4-4
− Source Timeslot Range(e.g.1,3-6): 1–5
− Sink Slot: 12-N2SL16-1(SDH-1)
− Sink VC4: VC4-5
− Sink Timeslot Range(e.g.1,3-6): 1–5
− Activate Immediately: Yes
− Click OK.
----End
The data configuration of NE3 is performed in the same way as that of NE2, except that some
parameters are different.
1. Click the NE switching shortcut icon . Select NE3, and click OK.
2. Select 14-N2EFS0 from the Object Tree and Configuration > Ethernet Interface
Management > Ethernet Interface from the Function Tree. Then, click .
3. Select External Port, and set as follows.
− Select the Basic Attributes tab. Set the Enabled/Disabled of the PORT1 to Enabled.
Click Apply.
− Select the TAG Attribute tab. Set the TAG of the PORT1 to Access. Set the Default
VLAN ID of the PORT1 to 11.
− Other items adopt the default value. Click Apply.
Step 2 Configuring bound paths
1. Select the Bound Path tab from the Internal Port page.
2. Click Configuration and the Bound Path Configuration dialog box is displayed.
3. To set bound paths for VCTRUNK1, set as follows in the dialog box.
− Configurable Ports: VCTRUNK1
− Level: VC12-xv
− Direction: Bidirectional
− Available Resources: VC4-4
− Select VC12-1 to VC12-5 from the Available Timeslots, and then click .
− Configurable Ports: VCTRUNK2
− Level: VC12-xv
− Direction: Bidirectional
− Available Resources: VC4-4
− Select VC12-6 to VC12-10 from the Available Timeslots, and then click .
− Click OK.
Step 3 Creating the EPLn service
1. Select Configuration > Ethernet Service > Ethernet LAN Service from the Function
Tree.
2. Click New and the Create Ethernet LAN Service dialog box is displayed.
3. Set the VB name to VB1.
4. Click Configure Mounted Port and the VB Mount Port Configuration dialog box is
displayed.
5. Set as follows in the dialog box according to the service configuration diagram of NE2.
Select PORT1, VCTRUNK1 and VCTRUNK2 for Available Mounted Ports, and click
. Click OK.
6. Click OK in the Create Ethernet LAN Service dialog box.
Step 4 Configuring the VLAN Forward Filter Table
1. Select Configuration > Ethernet Service > Ethernet LAN Service from the Function
Tree. Select VLAN tab.
2. Click New and the Create VLAN dialog box is displayed.
3. Set as following in the dialog box.
− VB: 1-VB1
− VLAN ID: 11
− Selected forwarding ports: PORT1, VCTRUNK1 and VCTRUNK2
− Click OK.
Step 5 Configuring the cross-connect from Ethernet boards to SDH line boards
1. Select NE3 from the Object Tree.
2. Select Configuration > SDH Service Configuration from the Function Tree.
3. Click Create and the Create SDH Service dialog box are displayed.
4. Set as follows in the dialog box.
− Level: VC12
− Direction: Bidirectional
− Source Slot: 14-N2EFS0-1(SDH-1)
The data configuration of NE4 is performed in the same way as that of NE2.
1. Click the NE switching shortcut icon . Select NE4, and click OK.
2. Select 15-N2EFS0 from the Object Tree and Configuration > Ethernet Interface
Management > Ethernet Interface from the Function Tree, and then click .
3. Select External Port, and set as follows.
− Select the Basic Attributes tab. Set the Enabled/Disabled of the PORT1 to Enabled.
Click Apply.
− Select the TAG Attribute tab. Set the TAG of the PORT1 to Access. Set the Default
VLAN ID of the PORT1 to 11.
− Other items adopt the default value. Click Apply.
Step 2 Configuring bound paths
1. Select the Bound Path tab from the Internal Port page.
2. Click Configuration and the Bound Path Configuration dialog box are displayed.
3. To set bound paths for VCTRUNK1, set as follows in the dialog box.
− Configurable Ports: VCTRUNK1
− Level: VC12-xv
− Direction: Bidirectional
Ethernet service can be created by trail or by station. If you purchase the license with trail management
function, you can create Ethernet service by trail; otherwise, you can only create Ethernet service by
station.
Table 3-15 shows the process of creating EPLn service on the T2000.
Step 5 Click Browse. Select the sink NE (NE2). In the pop-up interface, select N2EFS0, then select
VCTRUNK port 1, 4 for Higher Order, and VC4:4-VC12:1–VC4:4-VC12:5 for available
timeslot (lower order).
Step 6 Select the Activate check box, and leave the default setting for others.
Step 7 Click Apply to create the trunk link from NE3 to NE2.
Step 8 Create the trunk link from NE3 to NE4 similarly.
----End
Step 3 Select the trunk link created previously from Trunk Link Route Strategy and click Next.
Step 4 Set port attributes in the port attribute setting window. For PORT1 of NE2, NE3 and NE4:
z TAG: Access
z Port Enable: Enable
Step 5 Click Add in the VLAN configuration window, and set the following parameter in the VLAN
Configuration for Ethernet Trail window.
z VLAN ID: 11
z Select the PORT and VCTRUNK, click to select the port, and click OK.
Step 7 Set the name to be EPLn, select the Activate check box and click Finish.
----End