ATC221

Circuit

Chassis

Model

Part

Problem

Solution

Audio

ATC221

D34W135

BT960

No audio in DVD mode .Servicer found loose plug


BT960 to the DRI board

reseated BT960

Convergence

ATC221

D52W20YX1

FP251-FP2 Cycles, Convergence power supply is not


operational, found FP251 and FP221 open (off
LL008 flyback). (The convergence power had
been replaced )

Replaced FP221 & FP251

Convergence

ATC221

D40GW10YX1

TW19

no video, no convergence, Convergence power


supply dead. found TW19 open (on the
convergence amp board) .

replaced TW19

Picture Tube

ATC221

D52W20

Kine Drive

Set would cycle, Servicer found that by


disconnecting connector # BB203 the set would
start and run. With the connector plugged pin 1
(240 V supply line) measured a low resistance to
ground. IB201 green kine driver loading the
supply

Replaced IB201 (Green Output Driver)

Power Supply

ATC221

D52W20

IP020

Standby reg, IPO20 not running, it was open

replaced IP020

Circuit

Chassis

Model

Part

Problem

Solution

System Control

ATC221

D40W135DYX1

RP613

Remote not working after unit sets over night.


Unit will turn on at the FPA and then the remote
works OK untill it is turned off and left to sit for
around a minute, then the remote will not work
again untill you turn it on at the FPA. Found
RP613 not in

installed missing RP613

Safety information is contained in the appropriate Thomson Inc. Service Data.


All product safety requirements must be complied with prior to returning the instrument to
the consumer. Servicers who defeat safety features or fail to perform safety checks
may be liable for any resulting damages and may expose themselves and others to
possible injury.
2003 Thomson Inc. All Rights Reserved