Parameters and Signals

2013-10-01 11:37:02

Datei: M13256
Properties
Control Board Type

RMIO-1x

Kind
Name
Product Family

ACS800
ACS 800 0510_5MR
ACS 800 0510_5MR

System software version

4.200

Application
Base library

FFFFF.002

Name
Version

ASARF018
11-06-14 12:34:48:546

Parameters and Signals


01: SENALES ACTUALES
Name

Value

01.01: VELOC DE PROCESO [%]


01.02: VELOCIDAD [rpm]
01.03: FRECUENCIA [Hz]

0.0
0.0
0.00

01.04: INTENSIDAD [A]


01.05: PAR [%]
01.06: POTENCIA [%]
01.07: TENSION BUS CC V [V]
01.08: TENSION DE RED [V]
01.09: TENSION DE SALIDA [V]
01.10: TEMP DEL RADIADOR [%]
01.11: REF EXTERNA 1 [rpm]
01.12: REF EXTERNA 2 [%]
01.13: LUGAR DE CONTROL
01.14: RELOJ HORAS [h]
01.15: KILOWATIOS HORA [kWh]

0.00
0.00
0.00
0.0
461.9
0.0
23.3
0.0
0.0
EXT1
9.20
7.7

01.16: SALIDA BLOQUE APL [%]


01.17: ESTADO ED6 - 1
01.18: EA1 (V) [V]

0.0
0000000b
-0.0

01.19: EA2 (mA) [mA]


01.20: EA3 (mA) [mA]

0.0
0.0

01.21: ESTADO SR3 - 1


01.22: SA1 (mA) [mA]
01.23: SA2 (mA) [mA]

0000000b
0.0
0.0

01.24: VALOR ACTUAL 1 [%]


01.25: VALOR ACTUAL 2 [%]
01.26: DESVIACION CONTR [%]
01.27: MACRO APLICACION
01.28: SA1 EXT [mA]

0.0
0.0
0.0
FACTORY
0.0

01.29: SA2 EXT [mA]


01.30: PP 1 TEMP [C]

0.0
32.6

01.31: PP 2 TEMP [C]


01.32: PP 3 TEMP [C]
01.33: PP 4 TEMP [C]

0.0
0.0
0.0

01.34: VALOR ACTUAL [%]


01.35: TEMP MOTOR 1 [C]
01.36: TEMP MOTOR 2 [C]
01.37: TEMP MOT EST [C]
01.38: EA5 [mA]
01.39: EA6 [mA]
01.40: ESTADO ED7-12
01.41: ESTADO SR EXT
01.42: VELOCIDAD PROCESO [%]
01.43: CUENTAHORAS MOTOR [h]
01.44: RET MARCHA VENT [h]
01.45: TEMP TARJ CTRL [C]
01.46: SAVED KWH [kWh]
01.47: SAVED GWH [GWh]
01.48: SAVED AMOUNT [EUR]

0.0
0.0
0.0
30.0
0.0
0.0
0000000b
0001100b
0.0
1.17
4.10
42
408.6
0
0.0

01.49: SAVED AMOUNT M [MEU]


01.50: SAVED CO2 [kg]
01.51: SAVED CO2 KTON [kt]

0
204.3
0

02: SENALES ACTUALES


Name
02.01: REF VELOCIDAD 2 [rpm]

Value
0

02.02: REF VELOCIDAD 3 [rpm]


02.09: REF PAR 2 [%]

0
0.00

02.10: REF PAR 3 [%]


02.13: REF PAR USUAL [%]
02.14: REF FLUJO [%]

0.00
0.00
100

02.17: VELOC ESTIMADA [rpm]


02.18: VELOCIDAD MEDIDA [rpm]
02.19: ACELERACION MOTOR [rpm/s]
02.20: INTENS USUARIO [%]

0.0
0.00
0.0
0.0

03: SENALES ACTUALES


Name
03.01: COD PRPAL DE CTRL
03.02: COD PRPAL DE EST
03.03: CODIGO ESTADO AUX
03.04: CODIGO LIMITE
03.05: CODIGO FALLO 1
03.06: CODIGO FALLO 2
03.07: FALLO SISTEMA
03.08: CODIGO ALARMA 1
03.09: CODIGO ALARMA 2

Value
474h
12A8h
1800h
0h
0h
1000h
0h
0h
0h

03.11: COD PRAL CTRL ESC


03.13: COD AUX ESTADO 3
03.14: COD AUX ESTADO 4

0h
492h
0h

03.15: CODIGO FALLO 4


03.16: CODIGO ALARMA 4

0h
0h

03.17: CODIGO FALLO 5


03.18: CODIGO ALARMA 5

0h
0h

03.19: FALLO INI INT


03.20: 1.ULTIMO FALLO
03.21: 2.ULTIMO FALLO

0h
7510h
7510h

03.22: 3.ULTIMO FALLO


03.23: 4.ULTIMO FALLO
03.24: 5.ULTIMO FALLO
03.25: 1.ULTIMA ALARMA
03.26: 2.ULTIMA ALARMA
03.27: 3.ULTIMA ALARMA
03.28: 4.ULTIMA ALARMA
03.29: 5.ULTIMA ALARMA
03.30: CODIGO LIMITE INV
03.31: CODIGO ALARMA 6
03.32: EXT IO STATUS
03.33: CODIGO FALLO 6

7510h
7510h
7510h
FF8Dh
FF8Dh
FF8Dh
FF8Dh
FF8Dh
0h
0h
820h
0h

04: SENALES ACTUALES


Name
04.01: INFO FALLO INT
04.02: INFO INT CORTOC

Value
0h
0h

09: SEALES ACTUALES


Name
09.01: EA1 ESCALADA
09.02: EA2 ESCALADA
09.03: EA3 ESCALADA

Value
-11
12
0

09.04: EA5 ESCALADA


09.05: EA6 ESCALADA
09.06: DATA SET MCW

0
0
47Eh

09.07: MASTER REF1


09.08: MASTER REF2

0
0

09.09: AUX DS VAL1


09.10: AUX DS VAL2
09.11: AUX DS VAL3

0
0
0

09.12: LCU ACT SIGNAL1


09.13: LCU ACT SIGNAL2

0
0

10: MARCHA/PARO/DIR
Name
10.01: EXT1 MAR/PARO/DIR
10.02: EXT2 MAR/PARO/DIR
10.03: DIRECCION
10.04: EXT1 MAR PUNTERO
10.05: EXT2 MAR PUNTERO
10.06: SEL MARCHA LENTA
10.07: CONTROL DE RED
10.08: REFERENCIA DE RED
10.09: SLS ACTIVE

11: SELEC REFERENCIA

Value
COMM.CW
ED1,2
RETROCESO
+.000.000.00
+.000.000.00
SIN SEL
<Lesegeschtzt>
<Lesegeschtzt>
NO

Name
11.01: SELEC REF PANEL

Value
REF1 (rpm)

11.02: SELEC EXT1/EXT2


11.03: SELEC REF EXT1
11.04: REF EXT1 MINIMO [rpm]

ED3
REF COMUN
0

11.05: REF EXT1 MAXIMO [rpm]


11.06: SELEC REF EXT2
11.07: REF EXT2 MINIMO [%]
11.08: REF EXT2 MAXIMO [%]
11.09: SEL EXT 1/2 PUNT
11.10: SEL REF EXT1 PUNT
11.11: SEL REF EXT2 PUNT

1080
EA2
0
100
+.000.000.00
+.000.000.00
+.000.000.00

12: VELOC CONSTANTES


Name
12.01: SEL VELOC CONST
12.02: VELOC CONST 1 [rpm]
12.03: VELOC CONST 2 [rpm]
12.04: VELOC CONST 3 [rpm]
12.05: VELOC CONST 4 [rpm]
12.06: VELOC CONST 5 [rpm]
12.07: VELOC CONST 6 [rpm]
12.08: VELOC CONST 7 [rpm]
12.09: VELOC CONST 8 [rpm]

Value
ED4(VELOC4)
300
600
900
300
0
0
0
0

12.10: VELOC CONST 9 [rpm]


12.11: VELOC CONST 10 [rpm]
12.12: VELOC CONST 11 [rpm]

0
0
0

12.13: VELOC CONST 12 [rpm]


12.14: VELOC CONST 13 [rpm]

0
0

12.15: VELOC CONST 14 [rpm]


12.16: VELOC CONST 15 [rpm]

0
0

13: ENTRADAS ANALOG


Name
13.01: MINIMO EA1
13.02: MAXIMO EA1

Value
0V
10 V

13.03: ESCALA EA1 [%]


13.04: FILTRO EA1 [s]
13.05: INVERTIR EA1
13.06: MINIMO EA2
13.07: MAXIMO EA2
13.08: ESCALA EA2 [%]
13.09: FILTRO EA2 [s]
13.10: INVERTIR EA2
13.11: MINIMO EA3
13.12: MAXIMO EA3
13.13: ESCALA EA3 [%]
13.14: FILTRO EA3 [s]

100.0
0.10
NO
0 mA
20 mA
100.0
0.10
NO
0 mA
20 mA
100.0
0.10

13.15: INVERTIR EA3


13.16: MINIMO EA5
13.17: MAXIMO EA5

NO
0 mA
20 mA

13.18: ESCALA EA5 [%]


13.19: FILTRO EA5 [s]

100.0
0.10

13.20: INVERT EA5


13.21: MINIMO EA6

NO
0 mA

13.22: MAXIMO EA6


13.23: ESCALA EA6 [%]
13.24: FILTRO EA6 [s]

20 mA
100.0
0.10

13.25: INVERT EA6

NO

14: SALIDAS DE RELE


Name

Value

14.01: SALIDA RELE SR1


14.02: SALIDA RELE SR2
14.03: SALIDA RELE SR3

LISTO
EN MARCHA
FALLO (-1)

14.04: SR1 TON RETR [s]


14.05: SR1 TOFF RETR [s]
14.06: SR2 TON RETR [s]
14.07: SR2 TOFF RETR [s]
14.08: SR3 TON RETR [s]
14.09: SR3 TOFF RETR [s]
14.10: DIO MOD1 SR1
14.11: DIO MOD1 SR2
14.12: DIO MOD2 SR1
14.13: DIO MOD2 SR2
14.14: DIO MOD3 SR1
14.15: DIO MOD3 SR2

0.0
0.0
0.0
0.0
0.0
0.0
LISTO
EN MARCHA
FALLO
ALARMA
REF 2 SEL
REF=VEL ACT

14.16: SAL RELE PUNTERO1


14.17: SAL RELE PUNTERO2
14.18: SAL RELE PUNTERO3

+.000.000.00
+.000.000.00
+.000.000.00

14.19: SAL RELE PUNTERO4


14.20: SAL RELE PUNTERO5

+.000.000.00
+.000.000.00

14.21: SAL RELE PUNTERO6


14.22: SAL RELE PUNTERO7
14.23: SAL RELE PUNTERO8

+.000.000.00
+.000.000.00
+.000.000.00

14.24: SAL RELE PUNTERO9

+.000.000.00

15: SALIDAS ANALOG


Name

Value

15.01: SALIDA ANALOG 1


15.02: INVERTIR SA1
15.03: MINIMO SA1
15.04: FILTRO SA1 [s]
15.05: ESCALA SA1 [%]
15.06: SALIDA ANALOG 2
15.07: INVERTIR SA2
15.08: MINIMO SA2
15.09: FILTRO SA2 [s]
15.10: ESCALA SA2 [%]
15.11: SA1 PUNTERO
15.12: SA2 PUNTERO

SIN USAR
NO
0 mA
0.10
100
INTENSIDAD
NO
0 mA
2.00
100
+.000.000.00
+.000.000.00

16: ENTR CONTR SIST


Name
16.01: PERMISO DE MARCHA

Value
SI

16.02: BLOQUEO PARAMETRO


16.03: CODIGO ACCESO

ABIERTO
0

16.04: SEL RESTAUR FALLO


16.05: CAMB ES MACR USUA
16.06: BLOQUEO LOCAL

COMM.CW
SIN SEL
SI

16.07: SALVAR PARAMETROS


16.08: PERM MARCHA PTR
16.09: ALIM TARJ CTRL
16.10: SEL ASISTENTE
16.11: PUNT RESET FALLO
16.12: RESET COUNTER

REALIZADO
+.000.000.00
24 V EXT
ON
+.000.000.00
NO

20: LIMITES
Name
20.01: VELOCIDAD MINIMA [rpm]
20.02: VELOCIDAD MAXIMA [rpm]
20.03: INTENSIDAD MAXIMA [A]
20.04: LIM1 PAR MAXIMO [%]
20.05: CTRL SOBRETENSION
20.06: CTRL SUBTENSION
20.07: FRECUENCIA MINIMA [Hz]
20.08: FRECUENCIA MAXIMA [Hz]
20.11: LIMITE POT MOT [%]
20.12: LIMITE POT GEN [%]

Value
-1080
0
600.0
300.0
SI
SI
<Lesegeschtzt>
<Lesegeschtzt>
300.0
-300.0

20.13: SEL PAR MIN


20.14: SEL PAR MAX
20.15: LIM1 MIN PAR [%]

PAR NEG MAX


LIM1 MAXIMO
0.0

20.16: LIM2 MIN PAR [%]


20.17: LIM2 MAX PAR [%]

0.0
300.0

20.18: LIM MIN PAR PUNT


20.19: LIM MAX PAR PUNT
20.20: ESCALA MIN EA [%]

+.000.000.00
+.000.000.00
0.0

20.21: ESCALA MAX EA [%]


20.22: SLS SPEED LIMIT [rpm]

300.0
0

21: MARCHA/PARO
Name
21.01: FUNCION MARCHA
21.02: TIEMPO MAGN CONST [ms]
21.03: FUNCION PARO
21.04: RETENCION POR CC
21.05: VELOC RETENC CC [rpm]
21.06: INTENS RETENC CC [%]
21.07: PERMISO MARCHA
21.08: FLYSTART ESCALAR
21.09: FUN ENCL MAR
21.10: RET VELOC CERO [s]

Value
AUTO
500.0
RAMPA
NO
5
30.0
PARO EMERG3
<Lesegeschtzt>
PARO EMERG 2
0.50

22: ACEL/DECEL
Name
22.01: SEL ACEL/DECEL
22.02: TIEMPO ACELER 1 [s]

Value
ED5
38.00

22.03: TIEMPO DECELER 1 [s]


22.04: TIEMPO ACELER 2 [s]

38.00
60.00

22.05: TIEMPO DECELER 2 [s]


22.06: TIPO RAMPA ACE/DE [s]
22.07: TIEMP DEC STOP EM [s]

60.00
2.00
15.00

22.08: ACEL PUNTERO


22.09: DECEL PUNTERO
22.10: SLS ACCELER TIME [s]
22.11: SLS DECELER TIME [s]

+.000.000.00
+.000.000.00
20.00
20.00

23: CTRL VELOCIDAD


Name

Value

23.01: GANANCIA
23.02: TIEMP INTEGRACION [s]
23.03: TIEMPO DERIVACION [ms]
23.04: COMPENSACION ACE [s]
23.05: GANANCIA DESLZMTO [%]
23.06: MARCHA AUTOAJUSTE
23.07: TIEMP FILT VELACT [ms]

58.2
6.63
0.0
12.05
100.0
NO
103.5

25: VELOC CRITICAS


Name
25.01: SEL VELOC CRITICA
25.02: VELOC CRIT 1 BAJA [rpm]
25.03: VELOC CRIT 1 ALTA [rpm]
25.04: VELOC CRIT 2 BAJA [rpm]
25.05: VELOC CRIT 2 ALTA [rpm]
25.06: VELOC CRIT 3 BAJA [rpm]

Value
NO
0
0
0
0
0

25.07: VELOC CRIT 3 ALTA [rpm]

26: CONTROL MOTOR


Name

Value

26.01: OPTIMIZACION FLUJ


26.02: FRENADO FLUJO
26.03: COMPENSACION IR [%]

NO
NO
<Lesegeschtzt>

26.04: IR STEP UP FREQ [Hz]


26.05: DEBIL CAMPO HEX

<Lesegeschtzt>
OFF

26.06: REF FLUJO PUNT


26.07: FLYSTART CUR REF [%]
26.08: FLYSTART INIT DLY

C. 10000
50
25

26.09: FS METHOD

OFF

27: CHOPPER
Name

Value

27.01: CTRL CHOPPER


27.02: FUNC SOBREC RESIS
27.03: VALOR RESIST [Ohm]
27.04: CONST TERM RESIS [s]
27.05: POT FREN CONT MAX [kW]
27.06: MODO CTRL CHOPPER

OFF
NO
100.00
0.000
0.00
COMMON DC

30: FUNCIONES FALLOS


Name
30.01: EA<FUNCION MINIMA
30.02: FALLO PANEL
30.03: FALLO EXTERNO
30.04: PROT TERMICA MOT
30.05: MODO PROT TERM MO
30.06: TIEMPO TERM MOTOR [s]
30.07: CURVA CARGA MOTOR [%]
30.08: CARGA VELOC CERO [%]
30.09: PUNTO RUPTURA [Hz]
30.10: FUNCION BLOQUEO

Value
FALLO
FALLO
SIN SEL
NO
DTC
6432.7
100.0
74.0
45.0
FALLO

30.11: FREC ALT BLOQUEO [Hz]


30.12: TIEMPO BLOQUEO [s]
30.13: FUNC BAJA CARGA

20.0
20.00
NO

30.14: TIEMPO BAJA CARGA [s]


30.15: CURVA BAJA CARGA

600
1

30.16: FALLO FASE MOTOR


30.17: FALLO A TIERRA
30.18: FUNC FALLO COMUN

NO
FALLO
FALLO

30.19: FALL COM TIME-OUT [s]


30.20: FALL COM SR/AO
30.21: AUX DSET TIME-OUT [s]
30.22: FUNC CONFIG ES
30.23: ALARMA LIMITE

3.00
CERO
3.00
ALARMA
0000000b

31: REARME AUTOMATIC


Name
31.01: NUMERO TENTATIVAS
31.02: TIEMPO TENTATIVAS [s]
31.03: TIEMPO DE DEMORA [s]
31.04: SOBREINTENSIDAD
31.05: SOBRETENSION
31.06: SUBTENSION
31.07: SENAL EA<MIN
31.08: LINE CONV

Value
0
30.0
0.0
NO
NO
NO
NO
NO

32: SUPERVISION
Name
32.01: FUNCION VELOC 1

Value
NO

32.02: LIMITE VELOC 1 [rpm]


32.03: FUNCION VELOC 2
32.04: LIMITE VELOC 2 [rpm]

0
NO
0

32.05: FUNCION INTENS


32.06: LIMITE INTENSIDAD [A]

NO
0

32.07: FUNCION PAR 1


32.08: LIMITE PAR 1 [%]
32.09: FUNCION PAR 2

NO
0
NO

32.10: LIMITE PAR 2 [%]


32.11: FUNCION REF 1
32.12: LIMITE REF 1 [rpm]

0
NO
0

32.13: FUNCION REF 2

NO

32.14: LIMITE REF2 [%]


32.15: FUNCION ACT1

0
NO

32.16: LIMITE ACT1 [%]


32.17: FUNCION ACT2
32.18: LIMITE ACT2 [%]

0
NO
0

33: INFORMACION
Name
33.01: VERSION SW

Value
AS7R7365

33.02: VERSION SW APLI


33.03: FECHA PRUEBA
33.04: BOARD TYPE

ASARF018
0h
RMIO - 1X

34: VELOC DE PROCESO


Name
34.01: ESCALA

Value
100.00

34.02: UNIDAD
34.03: SEL VAR PROCESO
34.04: FILTRO VEL ACT [ms]
34.05: FILTRO PAR ACT [ms]
34.06: RESET CUENTAHORAS

%
142
500
100
NO

35: TEMP MOT MED


Name
35.01: SEL EA1 TEMP MOT1
35.02: ALARMA TEMP MOT1 [C]
35.03: FALLO TEMP MOT 1 [C]
35.04: SEL EA2 TEMP MOT2
35.05: ALARMA TEMP MOT 2 [C]
35.06: FALLO TEMP MOT 2 [C]
35.07: COMPENS MOD MOT
35.08: MOT MOD COMP PTR

Value
SIN USAR
110
130
SIN USAR
110
130
SI
+.000.000.00

40: CONTROL PID


Name
40.01: GANANCIA PID

Value
1.0

40.02: TIEMPO INTEG PID [s]


40.03: TIEMPO DERIV PID [s]
40.04: FILTRO DERIV PID [s]

60.00
0.00
1.00

40.05: INV VALOR ERROR


40.06: SEL VALOR ACTUAL

NO
ACT1

40.07: SEL ENTR ACTUAL 1


40.08: SEL ENTR ACTUAL 2
40.09: ACT1 MINIMO [%]

EA2
EA2
0

40.10: ACT1 MAXIMO [%]


40.11: ACT2 MINIMO [%]
40.12: ACT2 MAXIMO [%]
40.13: INTEGRACION PID
40.14: MODO TRIM
40.15: SEL REF TRIM
40.16: REFERENCIA TRIM [%]

100
0
100
ACTIVADO
DESACTIVADO
EA1
0.0

40.17: AJUSTE RANGO TRIM [%]


40.18: SELECCION TRIM

100.0
VELOC.TRIM

40.19: TIEMPO FILTRO ACT [s]


40.20: SELECCION DORMIR
40.21: NIVEL DORMIR [rpm]

0.04
<Lesegeschtzt>
<Lesegeschtzt>

40.22: RETRASO DORMIR [s]


40.23: NIVEL DESPERTAR [%]
40.24: RETRASO DESPERTAR [s]
40.25: ACTUAL 1 PUNTERO
40.26: MINIMO PID [%]
40.27: MAXIMO PID [%]
40.28: PUNTERO REF TRIM

<Lesegeschtzt>
<Lesegeschtzt>
<Lesegeschtzt>
+.000.000.00
-100.0
100.0
+.000.000.00

42: CONTROL FRENO


Name
42.01: CONTROL FRENO
42.02: RECONOC FRENO
42.03: RETR APERT FRENO [s]
42.04: RETR CIERRE FRENO [s]
42.05: VEL CIERRE FRENO [RPM]
42.06: FUNC FALLO FRENO
42.07: SEL REF PAR ARRAN
42.08: REF PAR ARRAN [%]
42.09: TIEMPO EXTEN MAR [s]

Value
DESACTIVADO
DESACTIVADO
0.0
0.0
10
FALLO
NO
0.0
0.0

42.10: MANT FRENO REF [s]

0.0

45: ENERGY OPT


Name

Value

45.02: ENERGY TARIFF1 [c/E]


45.06: E TARIFF UNIT
45.08: PUMP REF POWER [%]

0.000
EUR
100.00

45.09: ENERGY RESET

DONE

51: DATOS MODULO COM


Name

Value

51.01: MODULE TYPE


51.02: Comm rate

Ethernet
1

51.03: DHCP Enable


51.04: IP address 1
51.05: IP address 2

0
192
168

51.06: IP address 3
51.07: IP address 4
51.08: Subnet mask 1
51.09: Subnet mask 2
51.10: Subnet mask 3
51.11: Subnet mask 4
51.12: GW address 1
51.13: GW address 2
51.14: GW address 3
51.15: GW address 4
51.16: Protocol
51.17: Control Timeout

0
21
255
255
255
0
0
0
0
0
2
0

51.18: Stop function


51.19: Output 1

1
1

51.20: Output 2
51.21: Output 3
51.22: Output 4

2
0
0

51.23: Input 1
51.24: Input 2
51.25: Input 3
51.26: Input 4
51.27: FBA PAR REFRESH
51.28: FILE CPI FW REV
51.29: FILE CONFIG ID
51.30: FILE CONFIG REV
51.31: FBA STATUS
51.32: FBA CPI FW REV
51.33: FBA APPL FW REV

4
5
104
0
DONE
114h
101h
16h
OFF-LINE
130h
306h

52: MODBUS ESTANDAR


Name
52.01: NUM ESTACION
52.02: VEL TRANSM
52.03: PARIDAD

Value
1
9600
IMPAR

60: MAESTRO/ESCLAVO
Name
60.01: MODO MASTER
60.02: SELECTOR PAR
60.03: ACT SEL VENTANA

Value
SIN USAR
<Lesegeschtzt>
<Lesegeschtzt>

60.04: ANCHO POS VENT [rpm]


60.05: ANCHO NEG VENT [rpm]
60.06: TASA DE DROOP [%]

<Lesegeschtzt>
<Lesegeschtzt>
0.0

60.07: SENAL MAESTRO 2


60.08: SENAL MAESTRO 3

202
213

70: CONTROL DDCS


Name
70.01: DIREC CANAL 0

Value
1

70.02: DIREC CANAL 3


70.03: VEL TRANSM CH 1
70.04: CH0 DDCS HW CON

1
4 Mbit/s
ANILLO

70.05: CH2 DDCS HW CON

ANILLO

72: CURVA CARGA USUA


Name

Value

72.01: FUNCION SOBRECARG


72.02: INTENS CARGA 1 [%]
72.03: INTENS CARGA 2 [%]
72.04: INTENS CARGA 3 [%]
72.05: INTENS CARGA 4 [%]
72.06: INTENS CARGA 5 [%]
72.07: INTENS CARGA 6 [%]

NO
500.0
500.0
500.0
500.0
500.0
500.0

72.08: INTENS CARGA 7 [%]


72.09: INTENS CARGA 8 [%]

500.0
500.0

72.10: FREC CARGA 1 [%]


72.11: FREC CARGA 2 [%]
72.12: FREC CARGA 3 [%]

0.0
20.0
40.0

72.13: FREC CARGA 4 [%]


72.14: FREC CARGA 5 [%]
72.15: FREC CARGA 6 [%]
72.16: FREC CARGA 7 [%]
72.17: FREC CARGA 8 [%]
72.18: LIM INTENS CARGA [%]
72.19: TIEMP CARGA TERM [s]
72.20: TIEMP ENFRIAMIENT [s]

60.0
80.0
100.0
130.0
150.0
500.0
1.0
1

83: CTRL PROG ADAPT


Name
83.01: MODO PROG ADAPT
83.02: COMANDO EDICION
83.03: EDITAR BLOQUE
83.04: SEL TIEMPO EJEC
83.05: PASSCODE

Value
EDITAR
NO
0
100 ms
0

84: PROG ADAPTATIVO


Name
84.01: ESTADO
84.02: PARAM EN FALLO
84.05: BLOCK1
84.06: ENTRADA 1

Value
8h
+.000.000.00
NO
+.000.000.00

84.07: ENTRADA 2
84.08: ENTRADA 3
84.09: SALIDA

+.000.000.00
+.000.000.00
0

84.10: BLOCK2
84.11: ENTRADA 1

NO
+.000.000.00

84.12: ENTRADA 2
84.13: ENTRADA 3
84.14: SALIDA

+.000.000.00
+.000.000.00
0

84.15: BLOCK3
84.16: ENTRADA 1
84.17: ENTRADA 2
84.18: ENTRADA 3
84.19: SALIDA
84.20: BLOCK4
84.21: ENTRADA 1
84.22: ENTRADA 2
84.23: ENTRADA 3
84.24: SALIDA
84.25: BLOCK5
84.26: ENTRADA 1

NO
+.000.000.00
+.000.000.00
+.000.000.00
0
NO
+.000.000.00
+.000.000.00
+.000.000.00
0
NO
+.000.000.00

84.27: ENTRADA 2
84.28: ENTRADA 3
84.29: SALIDA

+.000.000.00
+.000.000.00
0

84.30: BLOCK6
84.31: ENTRADA 1

NO
+.000.000.00

84.32: ENTRADA 2
84.33: ENTRADA 3

+.000.000.00
+.000.000.00

84.34: SALIDA
84.35: BLOCK7
84.36: ENTRADA 1

0
NO
+.000.000.00

84.37: ENTRADA 2
84.38: ENTRADA 3
84.39: SALIDA
84.40: BLOCK8
84.41: ENTRADA 1
84.42: ENTRADA 2
84.43: ENTRADA 3
84.44: SALIDA
84.45: BLOCK9
84.46: ENTRADA 1
84.47: ENTRADA 2
84.48: ENTRADA 3
84.49: SALIDA
84.50: BLOCK10
84.51: ENTRADA 1

+.000.000.00
+.000.000.00
0
NO
+.000.000.00
+.000.000.00
+.000.000.00
0
NO
+.000.000.00
+.000.000.00
+.000.000.00
0
NO
+.000.000.00

84.52: ENTRADA 2
84.53: ENTRADA 3
84.54: SALIDA

+.000.000.00
+.000.000.00
0

84.55: BLOCK11
84.56: ENTRADA 1

NO
+.000.000.00

84.57: ENTRADA 2
84.58: ENTRADA 3
84.59: SALIDA

+.000.000.00
+.000.000.00
0

84.60: BLOCK12
84.61: ENTRADA 1
84.62: ENTRADA 2
84.63: ENTRADA 3
84.64: SALIDA
84.65: BLOCK13
84.66: ENTRADA 1
84.67: ENTRADA 2
84.68: ENTRADA 3
84.69: SALIDA
84.70: BLOCK14
84.71: ENTRADA 1

NO
+.000.000.00
+.000.000.00
+.000.000.00
0
NO
+.000.000.00
+.000.000.00
+.000.000.00
0
NO
+.000.000.00

84.72: ENTRADA 2
84.73: ENTRADA 3
84.74: SALIDA

+.000.000.00
+.000.000.00
0

84.75: BLOCK15
84.76: ENTRADA 1

NO
+.000.000.00

84.77: ENTRADA 2
84.78: ENTRADA 3
84.79: SALIDA

+.000.000.00
+.000.000.00
0

85: CONST USUARIO


Name
85.01: CONSTANTE 1

Value
0

85.02: CONSTANTE 2
85.03: CONSTANTE 3

0
0

85.04: CONSTANTE 4
85.05: CONSTANTE 5

0
0

85.06: CONSTANTE 6
85.07: CONSTANTE 7
85.08: CONSTANTE 8

0
0
0

85.09: CONSTANTE 9
85.10: CONSTANTE 10
85.11: STRING1
85.12: STRING2
85.13: STRING3
85.14: STRING4
85.15: STRING5

0
0
MESSAGE1
MESSAGE2
MESSAGE3
MESSAGE4
MESSAGE5

90: D SET REC DIRECC


Name
90.01: AUX DS REF3
90.02: AUX DS REF4
90.03: AUX DS REF5
90.04: FUENTE DS PRAL
90.05: FUENTE DS AUX

Value
0
0
0
1
3

92: D SET TR DIRECC


Name
92.02: DS PRAL ACT1
92.03: DS PRAL ACT2
92.04: DS AUX ACT3
92.05: DS AUX ACT4
92.06: DS AUX ACT5

Value
102
105
305
308
306

92.07: MSW B10 PTR


92.08: MSW B13 PTR
92.09: MSW B14 PTR

+.003.014.09
+.000.000.00
+.000.000.00

95: HARDWARE SPECIF


Name
95.01: MODO CTRL VENT

Value
CONTROLADO

95.02: CTRL SECC FUS


95.03: INT CONFIG USER

OFF
1

95.04: REQUER EX/SIN


95.05: PERM INC FREQ CON
95.06: LCU Q PW REF

NO
<Lesegeschtzt>
0

95.07: LCU DC REF


95.08: LCU PAR1 SEL
95.09: LCU PAR2 SEL
95.10: TEMP INV AMBIENT [C]
95.11: SUPPLY CTRL MODE
95.12: LCU RUN PTR

0
106
110
40.0
LINE CONV
+.000.000.00

98: MODULOS OPCIONAL


Name
98.01: MODULO TACO
98.02: MODULO COMUNIC

Value
NO
FIELDBUS

98.03: MOD EXT 1 E/S


98.04: MOD EXT 2 E/S

NO
NO

98.05: MOD EXT 3 E/S


98.06: MODULO EXT E/S A
98.07: PERFIL COMUN

NO
NO
ABB DRIVES

98.09: FUNC E/S EXT1


98.10: FUNC E/S EXT2
98.11: FUNC E/S EXT3
98.12: TEMP MOT ES AN
98.13: FUNC EA1 EXT
98.14: FUNC EA2 EXT
98.16: SUPERV FILT SEN

ED7,8,9
ED10,11,12
ED11,12
NO
EA5 UNIPOLAR
EA6 UNIPOLAR
<Lesegeschtzt>

99: DATOS DE PARTIDA


Name
99.01: IDIOMA
99.02: MACRO APLICACION
99.03: RESTAURAR APLIC
99.04: MODO CTRL MOTOR
99.05: TENSION NOM MOTOR [V]
99.06: INTENS NOM MOTOR [A]
99.07: FREC NOM MOTOR [Hz]
99.08: VELOC NOM MOTOR [rpm]
99.09: POTENCIA NOM MOT [kW]

Value
ESPANOL
FABRICA
NO
DTC
500
512.0
50.00
982
330.0

99.10: MARCHA IDENT MOT


99.11: NOMBRE APARATO

ID MAGN