PREDIMENSIONAMIENTO DE ELEMENTOS ESTRUCTURALES

LOSA ALIGERADA
L (m)

FACTOR
4.68

25.00

VIGAS
VIGA PRINCIPAL
L (m)

FACTOR
7.00

10.00

B (m)

0.30 SE USA EL ANCHO MINIMO PARA VIGA PRINCIPA


LA VIGA PRINCIPAL SERA DE : 0.30m. X 0.70m.
VIGAS
VIGA SECUNDARIA
L (m)

FACTOR
4.68

10.00

NOTA: POR DECISION PROPIA PARA EN ANALISIS SE USARA LA MISM


B (m)

0.30 SE USA EL MISMO ANCHO QUE LA VIGA PRINCIP


LA VIGA SECUNDARIA SERA DE : 0.30m. X 0.70m.
COLUMNAS
PS

n
92181.60

0.45

DETERMINACION DE LA CARGA DE SERVICIO PS


Kg/m3
LOSA ALIGERADA
VIGA SECUNDARIA

Kg/m2
300.00
2400.00

VIGA PRINCIPAL
ACAB. + TABIQU.
COLUMNA
SOBRECARGA

2400.00
250.00
2400.00
250.00

VERIFICACION DEL AREA DE COLUMNA

ALTERNATIVA PARA ANCHO DE COLUMNA

VERIFICACION DEL AREA DE COLUMNA

LA COLUMNA SERA DE : 0.56m. X 0.30m.


COLOCACION DE CARGAS
LOSA ALIGERADA
PESO DEL LADRILLO
TABIQ. + ACAB.

CARGA MUERTA
80.00
250.00
330.00

ANCHO SUPERIOR DE LOSA


ALIGERADA
CARGA DISTRIBUIDA

0.40
132.00
CARGA VIVA
250.00
250.00

S/C
ANCHO SUPERIOR DE LOSA
ALIGERADA
CARGA DISTRIBUIDA

0.40
100.00

CALCULO DEL PESO 2,3y 4 piso


Kg/m3
LOSA ALIGERADA
VIGA PRINCIPAL
VIGA SECUNDARIA
ACAB. + TABIQU.
COLUMNA

Kg/m2
300.00
2400.00
2400.00
250.00
2400.00

SOBRECARGA

250.00

CALCULO DEL PESO 5PISO


Kg/m3
LOSA ALIGERADA
VIGA PRINCIPAL
VIGA SECUNDARIA
ACABADOS
COLUMNA
SOBRECARGA

Kg/m2
300.00
2400.00
2400.00
100.00
2400.00
100.00

CALCULO DEL PESO 1PISO


Kg/m3
LOSA ALIGERADA
VIGA PRINCIPAL
VIGA SECUNDARIA
ACAB. + TABIQU.
COLUMNA
SOBRECARGA

Kg/m2
300.00
2400.00
2400.00
250.00
2400.00
250.00

DX
DY

7.00
21.00

CALCULO DE LA CORTANTE BASAL

V=/

Z
U
Cx
Cy
S
R

0.4
1
2.5
2.5
1.4
8

Vx=/
Vx

0.175

Vy=/
Vy

0.175

FACTOR DE AMPLIFICACION SISMICA ( C )

Cx=2.5 (/ )
2.5
Tx= 0.4342857143
H
15.20
Ctx=
35
Tp=
0.9
Cx
Cx

VX
VY

NIVELES

5.1809210526
2.5

0.175*P
0.175*P

122518.767
122518.767

ALT ACUM.
5
4
3
2
1

PESO
112068.600
146888.700
146888.700
146888.700
147372.540
700107.240

15.200
12.200
9.200
6.200
3.200

x
y

ALTURA DE LOSA
ALIGERADA

ALTURA DE LOSA
ALIGERADA(red.)

0.19

0.20 m

ALTURA DE VIGA
PRINCIPAL
0.70 m

EL ANCHO MINIMO PARA VIGA PRINCIPAL

.30m. X 0.70m.

ALTURA DE VIGA
SECUNDARIA

ALTURA DE VIGA
SECUNDARIA A USAR

0.47

0.70 m

ARA EN ANALISIS SE USARA LA MISMA ALTURA DE LA VIGA PRINCIPAL

EL MISMO ANCHO QUE LA VIGA PRINCIPAL

30m. X 0.70m.

f'c (Kg/cm2)

AREA DE COLUMNA
280

LONGITUD 1

731.6 cm2

LONGITUD 2
3.50

ALTURA
4.68
4.68

0.70

3.50
4.68

3.50

0.70
3.00

3.50

1000cm2
1000cm2

H de viga

4.68

A. columna
731.6

ANCHO DE COLUMNA
80%
0.56

0.70
1000cm2
1000cm2

A. columna
1680.00

LONGITUD 2

ALTURA

LUMNA SERA DE : 0.56m. X 0.30m.

MUERTA
Kg/m2
Kg/m2
Kg/m2
m.
Kg/m
VIVA
Kg/m2
Kg/m2
m.
Kg/m

LONGITUD 1
7.00

7.00

21.00
7.00
21.00
21.00

0.70
0.70
3.00

7.00

LONGITUD 1

21.00

LONGITUD 2
7.00

7.00

ALTURA

21.00
7.00
21.00
21.00

0.70
0.70
1.50

7.00

LONGITUD 1

21.00

LONGITUD 2
7.00

7.00

21.00
7.00
21.00
21.00

7.00

21.00

ALTURA
0.70
0.70
3.10

m
m

Cy=2.5 (/ )
2.5
m

Tx=
H
Ctx=
Tp=
Cy
Cy

KG
KG

ALT*PESO
1703442.720
1792042.140
1351376.040
910709.940
471592.128
6229162.968

-8.5
-1.5

F SISMICA X
33504.293
35246.918
26579.643
17912.368
9275.546
122518.767

VX
33504.293
68751.211
95330.853
113243.221
122518.767

SECCION 1

SECCION 2
0.30

N DE PISOS PESO PARCIAL


5.00
24570.00
5.00
11793.60

0.30
0.30

5.00
5.00
5.00
5.00

0.56

PS

2000cm2
2000cm2

NO PASA

2000cm2
2000cm2

OK

8820.00
20475.00
6048.00
20475.00
92181.60 Kg.

SECCION 1

SECCION 2
0.30
0.30
0.56

0.30

CANTIDAD
1.00
6.00
2.00
1.00
12.00

factor RNE
art.16.3

PESO PARCIAL
44100.00
21168.00
21168.00
36750.00
14515.20

25%

9187.50
146888.70

SECCION 1

SECCION 2
0.30
0.30
0.56

0.30

CANTIDAD

factor RNE
art.16.3

1.00
6.00
2.00
1.00
12.00
25%

PESO PARCIAL
44100.00
21168.00
21168.00
14700.00
7257.60
3675.00
112068.60

SECCION 1

SECCION 2
0.30
0.30
0.56

0.30

CANTIDAD

factor RNE
art.16.3

1.00
6.00
2.00
1.00
12.00
25%

PESO PARCIAL
44100.00
21168.00
21168.00
36750.00
14999.04
9187.50
147372.54

(/ )
0.4342857143 m
15.20
35
0.9
5.1809210526
2.5

MTZ X
35179.508
37009.263
27908.625
18807.986
9739.323

F SISMICA Y
33504.293
35246.918
26579.643
17912.368
9275.546
122518.767

VY
33504.293
68751.211
95330.853
113243.221
122518.767

MTZ Y
11726.503
12336.421
9302.875
6269.329
3246.441

Kg. Para 2,3y 4piso

Kg.

Kg.

CARGAS DE FUERZA AXIAL


Kgf
EJE A-1
EJE A-2
EJE A-3
EJE A-4
EJE A-5
EJE A-6

N DE PISO
1
2
3
4
5

DISTORSIONES ELASTICAS
SX
SY
X
Y
X
Y
0
0
0.00019
0.002575
0.002019
0.000058
0.000193
0.002612
0.001045
0.000049
0.000156
0.002236
0.001467
0.000034
0.000116
0.001707
0.000955
0.000017
0.000065
0.001003

LO SOLICITADO POR LA NORMA E-030

N DE PISO
1
2
3
4
5
N DE PISO
1
2
3
4
5

0.007

DISTORSIONES INELASTICAS
SX
SX
X
Y
X
Y
0.00000000
0.00000000
OK
OK
0.01211400
0.00034800
NO PASA
OK
0.00627000
0.00029400
NO PASA
OK
0.00880200
0.00020400
NO PASA
OK
0.00573000
0.00010200
OK
OK
SY
SY
X
Y
X
Y
0.00114000
0.01545000
OK
NO PASA
0.00115800
0.01567200
OK
NO PASA
0.00093600
0.01341600
OK
NO PASA
0.00069600
0.01024200
OK
NO PASA
0.00039000
0.00601800
OK
NO PASA