EI Series Bimetal Thermometers

featUReS

1% full span accuracy ASME B40.200 (ASME


B40.3 Grade A)
Maximum ambient temp. is 200F (94C)
Hermetically sealed case to prevent entry
of moisture, interior corrosion and coil
freeze-up.

SpecificationS
Ashcroft
Series:
Dial Sizes:
Stem Length:
Case & Stem:
Stem Dia:
Window:

External adjustment permits zero reset from


outside the case.

Dial:

Maxivison dial allows readability from any


angle without parallax error.

Pointer:
Connection:

Silicone coil dampening (up to 400F)


provides vibration dampening and improves
response time.

Connection
Location:
Ranges:

All-welded stainless steel construction


Heavy-Duty glass lens

Options:

Protection NEMA 4X/IP66


Five year limited warranty

EI
2, 3, 5
212-24 (1)
304 stainless steel, hermetically
sealed
.250
Heavy-duty glass, plastic or shatterproof glass optional
Maxivision, black figures on white
background
Black
Plain, pointed plain, 14 NPT, 12 NPT,
12 NPT union
Everyangle, Lower, Rear
80/120F-200/1000F
50/50C-100/500C
Code Description
C4 Individual calibration cert.
XCS Dual scale(2)
XDM Dial marking
XNH Stainless steel tag
XNN Paper tag
XPD Plastic window
XSG Shatter proof glass
X3B 38 stem dia. with 12 NPT
X02 14 NPT when 12 NPT is standard
XS1 Silicone free
XYW 316SS Housing(4) and stem

(1) Special or longer length available, consult factory


(2) Dual scale avilable with 3 and 5 case only
(3) Only available on rear connection
(4) Only available on 5 Everyangle with 60 connection

Thermowells must be used on all pressure or


velocity applications, to protect the stem of
thermometer from corrosion and physical
damage, and to facilitate removal of the
thermometer without disturbing the process.
Maximum ambient temperature is 200F (95C).

NE W
L
OPTIONASING

OU
316SS H EM
& ST
E ON 5
AVAILABL NGLE
A
EVERY

HoWtooRDeR

30

EI 60

040

0/250F

XNH

Dial Size: 3 Code 30


Case Style: EI
Stem Connection: 12 NPT Code 60
Stem Location: Rear Code R
Stem Length: 4 Code 040
Range: Code 0/250F
Options: Stainless steel tag

BULLETIN BM-EI

All specifications are subject to change without notice.


All sales subject to standard terms and conditions.
Ashcroft Inc. 2015 06/2015

Ashcroft Inc., 250 East Main Street, Stratford, CT 06614 USA


Tel: 203-378-8281 Fax: 203-385-0408
email: info@ashcroft.com www.ashcroft.com

EI Series Bimetal Thermometers


EI Series selection table
Case Size

Stem

Dial Code Style Conn. Code Location


Code
Plain
40
2 20
Pointed 50
Rear
1
4 NPT 60
112 NPT
2
42
Union
Everyangle
Union
1
60
3
30
1 2 NPT
Rear
3 30
EI
2 NPT 60
Rear
1
Lower
2 NPT 60
Lower
1
12 NPT
2 NPT 42
42 Everyangle
Union
Union
Everyangle
11
5 50
22 NPT 60
Rear
1
2 NPT 60
Lower

EI Series dual scale ranges

Stem Lengths
Available
S
Code Length Code
(inches)
R
212
4
6
9
12
15
18
24

E
R
R
L
L
EE

025
040
060
090
120
150
180
240

R
L

Dual scales are available in 3 and 5


dial sizes in the following ranges:

Temperature Range

inner

F*
C
/ Div. Fig.
/ Div. Fig.
Fahrenheit
Inter. Celsius
Inter.
80/120
2
20
50/50
1
10
20/120
20/120
2
20
30/130
1
10
0/50
1
5
0/200
0/100
1
10
20
2
0/250
10/150
2
20
50
50/300
0/200
50/400
0/300
50/550
5
50 50/450**
5
50
200/700
100/500**
100/800
200/1000** 10
100

EI
EI
EI
EI

Lower

EI

Everyangle

EI

Rear

EI

Lower

EI

Everyangle

A
2332
(53)
2332
(53)
2332
(53)
3532
(80)
3532
(80)
3532
(80)
5132
(128)
5132
(128)
5116
(128)

B
3
8
(10)
3
8
(10)
3
8
(10)
19
32
(15)
12732
(47)
19
32
(15)
23
32
(18)
15
1 16
(49)
23
32
(18)

C
3
8
(8)
5
16
(8)
3
8
(8)
3
8
(8)

S
(2)

NPT

Hex
11
16

S 212
412

(2)

11

16

412

(2)

11

16

412

(2)

258
(67)

4
(6)

(2)

11

3132
(89)

(2)

12132
(42)

10

(2)

3 8
(92)

4
(6)

(2)

16

26

25

40/160F

and

40/70C

0/200F

0/250F

30/130F

50/300F

50/400F

50/550F

100/800F

200/700F

200/1000F

Weight in
ounces(3)

Dial Connection
Size Location
2
Rear
(Plain)
2 Rear (Plain,
pointed stem)
2
Rear
(Threaded)
3
Rear

60/50C

20/120F

EI Dimensions
Case
Series
EI

and

40/120F

CONTACT FACTORY FOR ADDITIONAL STEM LENGTHS AND RANGES NOT LISTED

3
8
(8)

178
(48)

32132
(93)

(2)

and

and

and

40/50C

30/50C
20/90C

and 20/120C
and

0/55C

and

10/150C

and

10/290C

and

and

10/200C

50/400C

and 100/370C

and 100/550C**

Overtemperature limits
Top of Range F

outer

80/120F

up to 250
251/550
551/1000

Maximum
Over Temperatu
100% of span
50% of span
800F **

*Dual scale ranges available for all standard F ranges (3 and 5


case only)
**Satisfactory for continuous service up to 800F or 425C. Can be
used for intermittent service from 800 to 1000F, or 425 to 500C.
Use Ashcroft Duratemp thermometers for ranges above and below
those listed above.
Minimum stem length for these ranges is 4.
Minimum stem length for lower connection and Everyangle is 4.

1. Figures in parenthesis ( ) are in millimeters. All other dimensions are in inches.


2. Standard S dimensions are 212, 4, 6, 9, 12, 15, 18 and 24 inches. Standard stem diameter is 14 inch.
3. Add 1 oz. for every 2 inches of stem length.

DiMenSionS

S
B
A

D
1.00"

C
B

BULLETIN BM-EI

30EI60E
50EI60E
50EL60E

30EI42E
50EI42E
50EL42E

All specifications are subject to change without notice.


All sales subject to standard terms and conditions.
Ashcroft Inc. 2015 06/2015

Ashcroft Inc., 250 East Main Street, Stratford, CT 06614 USA


Tel: 203-378-8281 Fax: 203-385-0408
email: info@ashcroft.com www.ashcroft.com

También podría gustarte