Está en la página 1de 4

FLUX MONITORING

SUMMARY REPORT

MACHINE DATA
Type, Mfg
Tag - ID
Installation Year
Rewind Year
Cooling system
Winding Type
Insulation Class
Insulation Type
Voltage
Power
Full Load Current
Full Load Speed
Frequency
No Load Current
No Of Poles
No. of Coils/Pole
Synchronous Speed

MACHINE PHOTO

INFORMATION
: Fuji Electric
:
: 1996
:
: Air Only
: Form Wound
: F
: Epoxy Mica
RATINGS
: 11.8 kV
: 64.7 MW
:
:
: 50 Hz
:
: 2
: 7

SUMMARY
Asset
U 400

U 500

U 600

Indication
No Shorted turn any slot coil with
FDZC = 3
With FDZC = 2 Indication
small shorted turn at
Pole A coil 2
With FDZC = 3 Indication
small shorted turn at
Pole B coil 3
With FDZC = 4 No
indication shorted turn
at coil 4
With FDZC = 5 Indication
small shorted turn at
Pole B coil 5
With FDZC = 6 Indication
high shorted turn at Pole
B coil 6
With FDZC = 7 Indication
small shorted turn at
Pole B coil 7
No Shorted turn any slot
coil with FDZC = 3

Recommendation
Monitoring and get data with
FDZC aligned to each slot

Periodically monitoring for


shorted turns indication (coil 6)

Monitoring and get data with


FDZC aligned toeach slot

COMPARISON LAST MEASUREMENT DATA OF EACH EQUIPMENT

3/24/2015
1
Peak Size

0.8
0.6
0.4
0.2
0

Coil 1 Coil 2 Coil 3 Coil 4 Coil 5 Coil 6 Coil 7

Pole A 0.822 0.796 0.811 0.701 0.516 0.395 0.313


Pole B 0.822 0.796 0.812 0.703 0.515 0.396 0.318
Figure 1. Data Measurement U 400

3/24/2015
1
Peak Size

0.8
0.6
0.4
0.2
0

Coil 1 Coil 2 Coil 3 Coil 4 Coil 5 Coil 6 Coil 7

Pole A 0.837 0.844 0.838 0.643

0.47

0.368 0.299

Pole B 0.844 0.887 0.808 0.592 0.418 0.228 0.284


Figure 2. Data Measurement U 500

3/24/2015
1
Peak Size

0.8
0.6
0.4
0.2
0

Coil 1

Coil 2

Coil 3

Coil 4

Coil 5

Coil 6

Coil 7

Pole A 0.803

0.766

0.784

0.693

0.514

0.393

0.319

Pole B 0.803

0.769

0.782

0.692

0.516

0.39

0.319

Figure 3. Data Measurement U 600

COMPARISON LAST MEASUREMENT DATA PLOT OF EACH EQUIPMENT

Figure 4. Plot Leading Slot Overlay Unit 400 FDZC = 3

Figure 5. Plot Leading Slot Overlay Unit 500 FDZC = 3

Figure 6. Plot Leading Slot Overlay Unit 600 FDZC = 3