PREDIMENSIONAMIENTO CON LOSA ALIGERADA - Libro Alfaro Etabs pag.

333
VIGA
fc

210

210

210

210

210

210

210

210

Ancho Tributario

3.8

2.6

3.8

2.6

3.8

2.6

3.8

2.6

Carga Muerta

500

500

500

500

500

500

500

500

Carga Viva

400

400

400

400

400

400

400

400

1er Lado

5.5

5.5

5.5

5.5

2.8

2.8

2do Lado

2.8

2.8

25

25

25

25

25

25

25

25

31

26

37

31

25

25

27

25

210

210

210

210

210

Base
Peralte

VIGA
fc

210

210

210

Ancho Tributario

5.5

5.5

5.5

2.8

2.8

2.8

Carga Muerta

500

500

500

500

500

500

500

500

Carga Viva

400

400

400

400

400

400

400

400

1er Lado

3.8

2.6

3.8

3.8

2.6

3.8

3.8

2.6

2do Lado

2.6

2.6

27.5

27.5

27.5

25

25

25

25

25

31

26

39

25

25

29

27

25

Ancho Tributario=

5.5

Ancho de Alas en Viga T=

40

cm

Peralte efectivo=

19

cm

Base
Peralte

LOSA

COLUMNA
Z (Factor de zona)=
U(Coef. De Uso)=

0.3
1

C(Coef. De amplif. Ssmica)=

2.5

S(Factor de Suelo)=

1.2

Area Techada=
Numero de Pisos=

128.66
4

Pe(peso)=

514.64

Tn

Vs= ZUCSPe=

463176

Kg

nc (Nmero de columnas)=
n (Fact. desplzto permisible)=
fc=

18
0.007
210

Ec (Mdulo de elasticidad)= 217370.651193


H1 ( Altura del 1er piso)=

350

Base (proponer)

30

Peralte

26

kg/cm2
cm
cm
cm

MURO DE CORTE
Numero de Muros=
Espesor de Muro(proponer)=
Longitud =

5
20

cm

72

cm

abs pag. 333


210

210

210

210

3.8

2.6

3.8

2.6

500

500

500

500

400

400

400

400

4.5

4.5

4.5

4.5

25

25

25

25

37

32

28

25

210

210

210

210

4.5

4.5

4.5

500

500

500

500

400

400

400

400

3.8

3.8

2.6

3.8

2.6

2.6

25

25

25

25

34

28

25

35

ANLISIS SISMICO DINMICO


FACTOR DE ZONA

Z=

ZONA 2

0.3

FACTOR DE AMPLIACION SISMICA

Tp
C 2.5

FACTOR DE USO

U=

Edificacion comun

TIPO DE SUELO

C 2.5

ACELERACION ESPECTRAL

S=

SUELO INTERMEDIO

1.2

ZUCS
g
R

Sa

COEFICIENTE DE REDUCCION

R=
Tp=
g=

CONCRETO ARMADO

8
0.6
9.81

Sa

0.05

2.50

1.104

0.06

2.50

1.104

0.07

2.50

1.104

0.08

2.50

1.104

0.09

2.50

1.104

1.000

0.10

2.50

1.104

0.800

0.20

2.50

1.104

0.30

2.50

1.104

0.40

2.50

1.104

0.50

2.50

1.104

0.60

2.50

1.104

0.70

2.14

0.946

0.80

1.88

0.828

0.80

1.88

0.828

1.00

1.50

0.662

2.00

0.75

0.331

3.00

0.50

0.221

4.00

0.38

0.166

5.00

0.30

0.132

6.00

0.25

0.110

7.00

0.21

0.095

8.00

0.19

0.083

9.00

0.17

0.074

10.0

0.15

0.066

ESPECTRO DE PSEUDO-ACELERACIONES NTE E-030

1.200

Sa

0.600
0.400
0.200
0.000
0.00

2.00

4.00

6.00
T (seg)

CARGAS APLICADAS EN LA ESTRUCTURA (LOSA ALIGERADA) :

NIVEL 1
(Kg/m2)

NIVEL 2
(Kg/m2)

NIVEL
3
(Kg/m2)

8.00

10.00

12.00

LOSA

CM

500

500

400

CV

200

200

200

CIONES NTE E-030

10.00

12.00

ANLISIS ESTTICO
FACTOR DE ZONA

Z=

ZONA 2

0.3

FACTOR DE USO
Edificacion comun

U=

S=

1.2

R=
C=
g=

TIPO DE SUELO
SUELO INTERMEDIO
COEFICIENTE DE REDUCCION
CONCRETO ARMADO
Factor de amplificacion

2.5
9.81 m/s2

PESO DE LA EDIFICACIN

Pe =

514.64 Tn

V estat=

57.897 Tn

V dinam=

46.3176 Tn

CORTANTE BASAL

V dinmico > 80%(V esttico)

CORTANTE BASAL

Z *U * C * S * Pe
R

CORTANTE BASAL

Z *U * C * S * Pe
R

SISMO DE
DISEO

NIVEL DE DESEMPEO
Completamente
Operacional
Sismo Frecuente
Edificacin
(43 aos)
Comn
Sismo Ocasional
Edificacin
(72 aos)
Esencial
Sismo Raro
Edificacin de
(475 aos)
Seguridad Crtica
Sismo muy Raro
Edificacin de
(970 aos)
Seguridad Crtica

Operacional

Supervivencia

Edificacin
Comn
Edificacin
Esencial
Edificacin de
Seguridad Crtica

Edificacin
Comn
Edificacin
Esencial

O
Cerca al
Colapso

Edificacin
Comn