Documentos de Académico
Documentos de Profesional
Documentos de Cultura
San Juan Bautista - Reporte
San Juan Bautista - Reporte
PROYECTISTA: XXX
DESCRIPCION
TRAMO
De
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
LONGITUD
DIAMETRO
DIAMETRO
COEF.
GASTO
GASTO
VELOCIDAD
(m)
INTERIOR(mm)
EFECTIVO(mm)
H-WILLIAMS
INICIAL(lps)
FINAL(lps)
(m/s)
73.587
85.321
93.774
45.108
94.455
69.467
58.596
53.662
79.475
73.776
55.265
79.810
89.018
208.991
131.521
38.1
38.1
38.1
38.1
38.1
38.1
38.1
38.1
38.1
38.1
38.1
38.1
38.1
38.1
38.1
Pgina 1
38.1
38.1
38.1
38.1
38.1
38.1
38.1
38.1
38.1
38.1
38.1
38.1
38.1
38.1
38.1
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
1.250
1.250
1.250
1.250
1.250
1.250
1.250
1.250
1.250
1.250
1.250
1.250
1.250
1.250
1.250
1.250
1.250
1.250
1.250
1.250
1.250
1.250
1.250
1.250
1.250
1.250
1.250
1.250
1.250
1.250
1.096
1.096
1.096
1.096
1.096
1.096
1.096
1.096
1.096
1.096
1.096
1.096
1.096
1.096
1.096
METODO HA
Tabla de Clculo
METODO HARDY-CROSS/HAZEN-WILLIAMS
No. de tramos: 15
PERDIDA DE CARGA(m)
TUBERIA
2.514
2.915
3.204
1.541
3.227
2.374
2.002
1.834
2.716
2.521
1.888
2.727
3.042
7.141
4.494
ADICIONAL
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
COTA DE T.N.(m)
No. de nodos: 16
COTA PIEZOMETRICA(m)
INICIAL
FINAL
INICIAL
FINAL
3544.920
3542.419
3536.002
3529.265
3523.823
3516.909
3512.145
3512.321
3508.821
3499.985
3492.159
3487.066
3476.118
3470.596
3463.996
3542.419
3536.002
3529.265
3523.823
3516.909
3512.145
3512.321
3508.821
3499.985
3492.159
3487.066
3476.118
3470.596
3463.996
3462.000
3545.920
3543.405
3540.490
3537.286
3535.744
3532.517
3530.143
3528.141
3526.308
3523.592
3521.071
3519.183
3516.456
3513.414
3506.273
3543.405
3540.490
3537.286
3535.744
3532.517
3530.143
3528.141
3526.308
3523.592
3521.071
3519.183
3516.456
3513.414
3506.273
3501.779
Pgina 2
CARGA DISPONIBLE(m)
INICIAL
1.000
0.986
4.488
8.020
11.922
15.608
17.999
15.820
17.487
23.607
28.912
32.117
40.338
42.818
42.277
FINAL
0.986
4.488
8.020
11.922
15.608
17.999
15.820
17.487
23.607
28.912
32.117
40.338
42.818
42.277
39.779
OBSERVACIONES
Nodos
RESULTADOS EN NODOS
NODO
DESCRIPCION
COTA PIEZ.(m)
3545.920
COTA T.N.(m)
3544.920
PRESION(m)
1.000
Q (lps)
0.000
Q adic.(lps)
-1.250
TRAMOS
Q total (lps)
-1.250
De
Q (lps)
1.250
3543.405
3542.419
0.986
0.000
0.000
0.000
2
2
3
1
3540.490
3536.002
4.488
0.000
0.000
0.000
3
3
4
2
3537.286
3529.265
8.020
0.000
0.000
0.000
4
4
5
3
3535.744
3523.823
11.922
0.000
0.000
0.000
5
5
6
4
1.250
-1.250
1.250
-1.250
1.250
-1.250
1.250
-1.250
3532.517
3516.909
15.608
0.000
0.000
0.000
6
6
7
5
3530.143
3512.145
17.999
0.000
0.000
0.000
7
7
8
6
3528.141
3512.321
15.820
0.000
0.000
0.000
8
8
9
7
3526.308
3508.821
17.487
0.000
0.000
0.000
9
9
10
8
1.250
-1.250
1.250
-1.250
1.250
-1.250
1.250
-1.250
10
3523.592
3499.985
23.607
0.000
0.000
0.000
10
10
11
9
11
3521.071
3492.159
28.912
0.000
0.000
0.000
11
11
12
10
1.250
-1.250
1.250
-1.250
Pgina 3
Nodos
12
3519.183
3487.066
32.117
0.000
0.000
0.000
12
12
13
11
13
3516.456
3476.118
40.338
0.000
0.000
0.000
13
13
14
12
14
3513.414
3470.596
42.818
0.000
0.000
0.000
14
14
15
13
15
3506.273
3463.996
42.277
0.000
0.000
0.000
15
15
16
14
1.250
-1.250
1.250
-1.250
1.250
-1.250
1.250
-1.250
16
3501.779
3462.000
39.779
0.000
1.250
1.250
16
15
-1.250
Pgina 4