Está en la página 1de 1

RESISTENCIA A LA COMPRESION DE PROBETAS DE CONCRETO

CANTERA: ELIAN S.R.L.


UBICACIN: VIA EVITAMIENTO KM. 576
f'c: 175 kg/cm2
f'cr: 245 kg/cm2
A/C=0.50
Num.
Dias

Fuerza
(Lb)
7
7
14
14
28
28
28

65000
61500
90000
86000
99000
100000
103000

7
7
14
14
28
28
28

47000
53000
68000
73000
80000
81000
83000

7
7
14
14
28
28
28

45000
46000
58000
59400
72600
69500
71000

Fuerza
(Kg)
29510
27921
40860
39044
44946
45400
46762
A/C = 0.56
21338
24062
30872
33142
36320
36774
37682
A/C = 0.62
20430
20884
26332
26967.6
32960.4
31553
32234

Diamet.
(Cm)

Area
(Cm2)

Resist.
Resist.
Obtenida Promedio
(Kg/Cm2) (Kg/Cm2)
167
161
164
228
217
223
251
255
261
256

15.00
14.88
15.10
15.13
15.10
15.05
15.10

176.7146
173.8985
179.0786
179.7909
179.0786
177.8946
179.0786

15.00
15.10
15.10
15.08
14.96
15.02
15.02

176.7146
179.0786
179.0786
178.6046
175.7734
177.1861
177.1861

121
134
172
186
207
208
213

15.00
15.05
15.10
15.16
15.00
15.22
15.10

176.7146
177.8946
179.0786
180.5046
176.7146
181.9362
179.0786

116
117
147
149
187
173
180

Comentario:
De las tres relaciones a/c ensayadas tenemos que la que cumple con la resistencia
de diseo requerida (245 km/Cm2) es la relacion a/c = 0.50.
En la relacin a/c = 0.50 el resultado de las probetas ensayadas a los 7 das es de
64% (164/256) de la resistencia probada a los 28 das.

128
179

209

117
148

180

También podría gustarte