Documentos de Académico
Documentos de Profesional
Documentos de Cultura
Electronics
Industry standard footprint, 30% more power handling
Power Range: Up to 70W
Height: 14.0mm Max
Footprint: 17.7mm x 14.5mm Max
Topology: Forward and Flyback
Pulse PN
PA3855.001NL
PA3855.002NL
PA3855.003NL
PA3855.004NL
pulseelectronics.com
Schematic
Flyback Transformer
Text
5.33
Flyback Transformer
2.67
Flyback Transformer
4.33
Flyback Transformer
P719.B (5/13)
Pulse Jack
High Frequency Wire Wound Transformers
EP13Plus Platforms - SMT
Pulse PN
PA3855.005NL
PA3855.006NL
PA3856.001NL
PA3856.002NL
PA3856.003NL
pulseelectronics.com
Electronics
Schematic
2.25
Flyback Transformer
1.33
0.89
Flyback Transformer
Forward Transformer
Forward Transformer
1.71
0.86
Forward Transformer
P719.B (5/13)
Pulse Jack
High Frequency Wire Wound Transformers
EP13Plus Platforms - SMT
Electronics
Pulse PN
PA3856.004NL
PA3856.005NL
PA3856.006NL
Schematic
1.6
1.2
Forward Transformer
1.14
Forward Transformer
0.47
0.82
Forward Transformer
Notes:
1. The temperature of the component (ambient plus temperature rise) must be within the 4. The standard pin-numbering for this package is indicated in the below mechanical
stated operating temperature range.
drawing showing pin 1 on the lower right corner and the numbers proceeding clockwise
to pin 10 on the upper right corner.
2. For flyback topology applications, it is necessary to ensure that the transformer will not
saturate in the application. The peak flux density (Bpk) should remain below 2700Gauss. 5. Optional Tape & Reel packaging can be ordered by adding a T suffix to the part
To calculate the peak flux density use the following formula:
number (i.e. (PA3855.001NL becomes PA3855.001NLT). Pulse complies with industry
Bpk (Gauss) = K1_Factor * Ipk(A)
standard tape and reel specification EIA481. The tape and reel for this product has a
width (W=32mm), pitch (Po=24mm) and depth (Ko=13.2mm).
3. In high volt-sec applications, it is important to calculate the core loss of the transformer. Approximate transformer core loss can be calculated as:
CoreLoss (W) = 3.84E-14 * (Freq_kHz)1.63 * (DB_Gauss)2.63
where DB can be calculated as:
For Flyback Topology: DB = K1_Factor * D(A)
For Forward Topology: DB = K1_Factor * Volt-sec
pulseelectronics.com
P719.B (5/13)
Pulse Jack
High Frequency Wire Wound Transformers
EP13Plus Platforms - SMT
Electronics
Mechanical
PA3855.XXNL/ PA3856.XXNL
Pulse Europe
Zeppelinstrasse 15
71083 Herrenberg
Germany
pulseelectronics.com
P719.B (5/13)