Está en la página 1de 15

Ejemplo 4-1 Dimensionamiento de un separador vertical

qg
qo
P
T
tretencion
API
gas

l=

10
2000
1000
60
140
3
40
0.6

MMSCFD
BOPD
psia
F
micrometros
min

1 Calculo de CD
51.4845481 lb/ft3

z=

0.84

pg

3.708791209

Viscosidad pag 94 Arnold

API
z
y
x

40
2.2232
167.1860357
1.429585372
25.88966381 cp
0.013

Re
Cd
0.86632686 169.5488815 0.71194749

2 CALCULO DE CAPACIDAD DE GAS

Re
0.59892797 117.216228

d2=
d=

479.144971
21.88938033
3 CALCULO DE CAPACIDAD DE LIQUIDO

tr

d2h
3

d
50000

h
24
30
36
42
48

Lss
86.8055556
55.5555556
38.5802469
28.3446712
21.7013889

Lss
13.6
11.0
9.5
8.7
8.1

Sr
12.4
9.8
8.4
7.5
7.0

Cd
0.82184397

Re
Cd
0.55744739 109.098062 0.84720429

Re
Cd
0.54904065 107.452778 0.85276319

V
0.54724821

Re

Cd
107.10198 0.85396833

Re
Cd
0.54686193 107.026381 0.85422898

Re
Cd
0.54677849 107.010051 0.85428532

Re
Cd
0.54676046 107.006523
0.8542975

Re
0.54675657

107.00576

Cd
0.85430013

Re
Cd
0.54675572 107.005595
0.8543007

Re
Cd
0.54675554 107.005559 0.85430083

También podría gustarte