Está en la página 1de 6

DATOS

CAUDAL
ANCHO SE SOLERA
TIRANTE CONJUGADO MAYOR
TIRANTE CRITICO
TALUD

Q
b
y3
yc
Z

0.34
0.6
0.471
0.27
1

UNIDADES
m3/seg
m
m
m

REGIMEN SUBCRITICO CONOCIDO (TIRANTE CONJUGADO MAYOR CONOCIDO=Y2)


CALCULO DE LOS PARAMETROS r y t
CALCULO DE V2

CALCULO DEL VALOR DE r

CALCULO DEL VALOR DE t

PROCEDEMOS A CALCULAR EL PARAMETRO J

CALCULAMOS J UTILIZANDO EL METODO DE NEWTON RAPSOM


f(J)=
COEFICIENTES

J^4
1

J^3
4.184713376

J^2
6.6188892

f(J)=

J^3

J^2

J^1

COEFICIENTES

12.55414013

13.2377784

MEDIANTE ITERACIONES CALCULAMOS EL VALOR DE J

n
0
1
2
3
4
5
6
7
8
9
10

J(n)
F(J)
0
-1.525125371
0.50212405 2.26216377
0.33274985 0.384847703
0.28989191 0.020620052
0.28732318 7.09241E-05
0.28731428 8.48561E-10
0.28731428
0
0.28731428
0
0.28731428
0
0.28731428
0
0.28731428
0

EL VALOR DEL PARAMETRO J ES:

J=

F(J)
3.03734778
13.3560113
8.97961334
8.02733589
7.97214994
7.97195918
7.97195917
7.97195917
7.97195917
7.97195917
7.97195917
0.287

CALCULAMOS EL TIRANTE CONJUGADO MENOR

CAUDAL
ANCHO DE SOLERA
TIRANTE CONJUGADO
AREA HIDRAULICA
VELOCIDAD
PERIMETRO MOJADO
ESPEJO
ENERGIA ESPECIFICA
FROUD
REGIMEN
PENDIENTE
ALTURA DEL RESALTO
EFICIENCIA DEL RESALTO
VARIACION DE LA ENERGIA
TIPO DE RESALTO

Q
b
y
A
V
P
T
E
F
S
Y
E

LONGITUD DEL RESALTO SEGN SIECHIN

SECCION(y2)

SECCION(y3)

0.34
0.6
0.135
0.100
3.417
0.983
0.871
0.730

0.34
0.6
0.471
0.504
0.674
1.932
1.542
0.494

3.227

0.376

SUPERCRITICO

SUBCRITICO

0.0048

0.00150
0.336
0.677
0.236
RESALTO OSCILANTE

TALUD (Z)
K
ENTONCES LA LONGITUD DEL RESALTO SERA

0
5

0.5
7.9
L=

R CONOCIDO=Y2)

v2= 0.67401341

r=

0.0491606

t= 1.27388535

J^1
J^0
3.03734778 -1.52512537
J^0

m/seg

ILANTE

3.03734778

J(n+1)
0.50212405
0.33274985
0.28989191
0.28732318
0.28731428
0.28731428
0.28731428
0.28731428
0.28731428
0.28731428
0.28731428

Y1=

UNIDADES
m3/seg
m
m
m2
m/seg
m
m
m.kg/kg

m/m

m.kg/kg

0.135

0.75
9.2
3.5581547

1
10.6
m

1.25
12.6

1.5
15

También podría gustarte