DIgSILENT

Red Externa

U1l=223,080 kV
u1=1,014 p.u.
phiu1=-81,570 d..
Ul=223,080 kV
u=1,014 p.u.
phiu=-81,570 deg

GUADALUPE 220kV

P=-0,05 MW
Q=0,94 Mvar
loading=1,69 %

GALLITO CIEGO CAJAMARCA

P=12,00 MW
Q=2,97 Mvar
loading=24,24 %

SAN MARCOS
P=11,07 MW
Q=6,39 Mvar
loading=66,20 %

Ul=58,513 kV
u=0,975 p.u.
phiu=-89,749 deg

P=-11,00 MW
Q=-5,33 Mvar
loading=66,20SAN
%

CAJAMARCA 10kV
Ul=9,756 kV
u=0,976 p.u.
phiu=116,888 deg

Transform..

MARCOS 23kV

G
~

CAJABAMBA23kV

Ul=10,135 kV
u=1,014 p.u.
phiu=118,857 deg

Carga Gen..

P=-16,76 MW
Q=-0,22 Mvar
loading=13,52 %

Ul=138,992 kV
u=1,007 p.u.
phiu=-83,047 deg

Carga Gen..

P=0,51 MW
Q=0,26 Mva..
=

P=0,51 MW
Q=0,25 Mva..
=

P=0,61 MW
Q=0,31 Mva..
=

Ul=60,429 kV
u=1,007 p.u.
phiu=-89,737 deg

P=8,86 MW
Q=-2,65 Mvar
loading=27,75 %

P=1,61 MW
Q=1,73 Mvar
loading=5,38 %

P=3,00 MW
Q=-1,61 Mvar
loading=37,59 %

P=-4,62 MW
Q=-0,12 Mvar
loading=8,86 %

Ul=2,936 kV
u=0,979 p.u.
phiu=-89,643 deg
Transform..

P=1,20 MW
Q=0,39 Mvar
b loading=64,53 %

P=-0,00 MW
Q=-3,12 Mvar
=

Transform..

P=0,80 MW
Q=0,23 Mvar
loading=42,67 %

P=-3,00 MW
Q=1,70 Mvar
loading=37,59 %

P=-1,20 MW
Q=-0,36 Mvar
loading=64,53 %

P=-0,80 MW
Q=-0,22 Mvar
loading=42,67 %

LPC1/LPC2
P=-0,00 MW
Q=0,00 Mvar
loading=37,59 %

Ul=60,453 kV
u=1,008 p.u.
phiu=-89,700 deg

P=5,00 MW
Q=2,00 Mva..
=

3kV a

Ul=2,926 kV
u=0,975 p.u.
phiu=-60,050 deg
Ul=137,963 kV
u=1,000 p.u.
phiu=-85,680 deg

P=4,62 MW
Q=0,11 Mvar
loading=8,86 %

CARGA ANTIGUA

Ul=25,477 kV
u=1,019 p.u.
phiu=-90,962 deg
Ul=137,438 kV
u=0,996 p.u.
phiu=-86,668 deg

P=16,99 MW
Q=-5,10 Mvar
loading=13,52 %

60kV LPC-2

P=-13,62 MW
Q=-3,11 Mvar
loading=71,10 %

LPC1 25kV

138kV LAGUNA NORTE


Transform..

Ul=9,986 kV
u=0,999 p.u.
phiu=119,231 deg

Transform..

~
G

P=0,80 MW
Q=0,23 Mvar
loading=41,62 %

Mquina S..

P=7,90 MW
Q=2,87 Mva..
=

P=-0,00 MW P=-17,04 MW
Q=-0,00 Mvar Q=-8,03 Mvar
loading=9,48 % loading=9,48 %

CAJABAMBA10kV

Ul=22,908 kV
u=0,996 p.u.
phiu=-90,576 deg

Carga Gen..

P=0,46 MW
Q=0,24 Mva..
=

Mquina S..

TRUJILLO NORTE 10kV

P=-0,51 MW
Q=-0,26 Mvar
loading=22,95 %
Transform..

60kV LPC-1 MORENA 60KV

13.8kV LAGUNA NORTE

Ul=10,071 kV
u=1,007 p.u.
phiu=-53,072 d..

P=1,02 MW
Q=0,53 Mvar
loading=22,95 %

Carga Gen..

P=11,00 MW
Q=5,33 Mva..
=

TRUJILLO NORTE 220kV

P=17,13 MW
Q=8,59 Mvar
loading=9,48 %

P=-1,59 MW
Q=-2,24 Mvar
loading=5,38 %

P=-0,51 MW
Q=-0,25 Mvar
loading=22,95 %

SAN MARCOS 10kV

3kV

Ul=222,281 kV
u=1,010 p.u.
hiu=-82,689 deg

P=-0,61 MW
Q=-0,31 Mvar
loading=33,81 %

Carga Gen..

Mquina S..

P=12,00 MW
Q=2,97 Mvar
loading=61,81 %

P=-17,13 MW
Q=-8,59 Mvar
loading=12,96 %

CAJABAMBA
Ul=59,169 kV
u=0,986 p.u.
phiu=-89,909 deg

P=1,07 MW
Q=0,58 Mvar
loading=33,81 %

P=-0,46 MW
Q=-0,24 Mvar
loading=33,81 %

Ul=23,312 kV
u=1,014 p.u.
phiu=-90,657 deg

CAJABAMBA/ LPC-1

P=0,57 MW
Q=1,72 Mvar
loading=4,24 %

Transform..

GUADALUPE/TRUJILLO NORTE

GALLITO
Ul=10,710 kV
u=1,020 p.u.
phiu=129,624 deg

SAN MARCOS/ CAJABAMBA

P=-0,55 MW
Q=-2,06 Mvar
loading=4,24 %

P=-0,52 MW
Q=1,49 Mvar
loading=4,09 %

P=0,53 MW
Q=-1,97 Mvar
loading=4,09 %

Transform..

CAJAMARCA
GALLITO CIEGO
Ul=57,912 kV
Ul=62,357 kV
P=-11,92 MW
u=0,965 p.u.
Q=-2,44
Mvar
u=1,039 p.u.
phiu=-81,476 deg loading=24,24 % phiu=-89,105 deg

Ul=62,623 kV
u=1,044 p.u.
phiu=-81,565 deg

CAJAMARCA SAN MARCOS

P=11,82 MW
P=-11,59 MW
Q=5,11 Mvar
Q=-4,42 Mvar
loading=24,84 % loading=24,84 %

P=0,05 MW
Q=-1,33 Mvar
loading=3,21 %

GUADALUPE/ GALLITO CIEGO L2

Compensac..

P=-0,05 MW
Q=0,94 Mvar
loading=3,21 %

P=0,05 MW
Q=-1,33 Mvar
loading=3,21 %

Transform..

60kV

P=0,05 MW
Q=-0,94 Mvar
loading=1,69 %

GUADALUPE/ GALLITO CIEGO L1

~
G

P=0,05 MW
Q=-0,94 Mvar
loading=1,69 %

P=-0,05 MW
Q=0,94 Mvar
loading=3,21 %

P=1,20 MW
Q=0,39 Mvar
loading=63,16 %

Transform..

P=-0,05 MW
Q=0,94 Mvar
loading=1,69 %
Transform..

P=18,15 MW
Q=-8,35 Mvar
loading=12,96 %

P=13,62 MW
Q=3,88 Mvar
loading=71,10 %

CARGA NUEVA
P=9,00 MW
Q=3,00 Mva..
=

138kV LPC2
TRUJILLO /LAGUNA NORTE

SVC

P=0,05 MW
Q=13,13 Mv..
=

TRUJULLO NORTE 138kV

LAGUNA NORTE- LPC

P=-8,82 MW
Q=-2,17 Mvar
loading=27,75 %
138kV B

Carga Gen..

P=-3,20 MW P=-1,60 MW
Q=-0,77 Mv.. Q=-0,94 Mv..
=
=

Flujo Carga Balanceada


Nodos
Ul Tensin Lnea-Lnea, Magnitud [kV]
u Tensin, Magnitud [p.u.]

Ramas
P Potencia Activa [MW]
Q Potencia Reactiva [Mv

phiu Tensin, ngulo [deg]

loading Nivel de Carga

FLUJO DE
POTENCIA- FIEE
PowerFactory 14.0.524

BACH. JHANS WALDO, DE LA CRUZ BRAEZ.


Proyecto:MAX AVE
"MEJORAMIENTO DEL SUMINISTRO ELCTRICO Grfica: PODEROSA
MEDIANTE LA INTERCONEXIN DE LAS
Fecha:
SUBESTACIONES DE POTENCIA LPC II - MORENA Anexo: