Está en la página 1de 3

Client: KTS No.

Project: Job No
Vessel: RFS signed
I/V date
Clause Remarks Yes No
1 ASME Edition and Addenda specified?
2 ASME material used?
3 Check design data consistent - dwg and calc
4 Check UG-22 loading addressed UG-22
5 Shell , min thick UG-16(b) UG 27
5.1 If external pressure, check effective length UG-28
6 Head, min thick UG-16(b) UG 32
7 Fibre Elongation > 5% for UCS materials UCS 79
7.1 Check fibre elongation for shell UCS 79
7.2 Check fibre elongation for head UCS 79
7.3 Check fibre elongation for nozzles rolled from plate UCS 79
8 Nozzle reinforcement UG 37
8.1 Large opening required App 1-7 UG 36 (b)
9 Size of inspection opening UG 46
10 Nozzle thickness
Including small nozz i.e. etc
UG-45
11 Flange rating ASME B16-5
11.1 Non std flange - App 2 calculation provided App 2
12 Fillet size checked? UW-16
13 MDMT specified in drawing
14 Impact required? UCS-66,UG-
20(f),UHA-51
15 Drain per UG-25(f) UG-25(f)
16 PWHT required? UCS-56 UCS-56,UHA-32
17 HT Pressure UG-99 UG-99
18 Check U stamp name plate drawing
19 Verify calculation for supports -lug,saddle etc are
available
U-STAMP PV CHECKLIST
5000 1.5 2
6000 42.6 56.8
7000 51.1 68.2
59.7 79.5
1534.1 3636.4 5170.5
1840.9 4363.6 6204.5
2147.7 5090.9 7238.6

También podría gustarte