Está en la página 1de 738

Ahead of the Curve

SM
Ref. No. 0311430 April 11, 2013
428XL
V5.0.22
Users Manual
Vol. 1
To contact Sercel
Europe
Nantes, France
Sales; Customer Support;
Manufacturing & Repair.
B.P. 30439, 16 rue de Bel Air
44474 Carquefou Cedex
Tel: +33 2 40 30 11 81, Fax: +33 2 40 30 19 48
Hot-Line: Land: +33 2 40 30 58 88
Marine: +33 2 40 30 59 59
Navigation: +33 2 40 30 69 87
E-mail: sales.nantes@sercel.com
customersupport.land@sercel.com
customersupport.marine@sercel.com
customersupport.navigation@sercel.com
repair.france@sercel.com
streamer.repair@sercel.com
www.sercel.com
St Gaudens, France
Vibrator Customer Support;
Vibrator Manufacturing & Repair;
Streamer Manufacturing & Repair.
Tel: +33 5 61 89 90 00, Fax: +33 5 61 89 90 33
Hot Line: +33 5 61 89 90 91
E-mail: customersupport.vib@sercel.com
customersupport.vsp@sercel.com
Les Ulis, France
Sales; Customer Support
Tel: +33 1 69 93 83 60, Fax: +33 1 69 81 78 09
E-mail: vspsupport@sercel.com
Hot Line: +33 6 15 54 13 96
Brest, France
Sales; Customer Support
Tel: +33 2 98 05 29 05; Fax: +33 2 98 05 52 41
E-mail: sales.nantes@sercel.com
Toulon, France
Sales; Customer Support
Tel: +33 4 94 21 69 92; Fax: +33 4 94 21 73 44
E-mail: SalesMSBU@sercel.com
SupportMSBU@sercel.com
Toulouse, France
Sales; Customer Support
Tel: +33 5 61 34 80 74; Fax:+33 5 61 34 80 66
E-mail: support@metrolog.com
sales@metrolog.com, info@metrolog.com
Alfreton, U. K.
Streamer Manufacturing & Repair;
Customer Support.
Tel: +44 1 773 605 078, Fax: +44 1 773 541 778
E-mail: streamer.repair@sercel.com
Trondheim, Norway (Optoplan AS)
Tel: +47 73820500, Fax: +47 73820599
Russia
Customer Support; Repair.
Moscow, Russia
Tel: +7 495 644 08 05, Fax: +7 495 644 08 04
E-mail: repair.cis@geo-mail.org
support.cis@geo-mail.org
Surgut, Russia
Tel: +7 3462 28 92 50
North America
Houston, Texas, USA
Sales; Customer Support;
Manufacturing & Repair;
Tel: +1 281 492 66 88, Fax: +1 281 579 75 05
Hot-Line: +1 281 492 66 88
E-mail:
sales.houston@sercel.com
HOU_Customer.Support@sercel.com
HOU_Training@sercel.com
HOU_Customer.Repair@sercel.com
Tulsa, Oklahoma, USA
Tel: +1 918 834 96 00, Fax: +1 918 838 88 46
E-mail:
support@sercel-grc.com
sales@sercel-grc.com
Calgary, Alberta, Canada
Sales; Customer Support; Manufacturing.
Tel: +1 403 275 3544, Fax: +1 403 295 1805
E-mail:
Cal_Customer.Support@sercel.com
Middle East
Dubai, U. A. E.
Sales, Customer Support, Repair.
Tel: +971 4 8832142, Fax: +971 4 8832143
Hot Line: +971 50 6451752
E-mail: dubai@sercel.com
repair.dubai@sercel.com
Far East
Beijing, P. R. of China
R & D.
Tel: +86 106 43 76 710, Fax: +86 106 43 76 367
E-mail: support.china@geo-mail.com
repair.china@geo-mail.com
Xian, P. R. of China
Manufacturing & Repair.
Tel / Fax: +86 29 8222 9504
Xushui, P. R. of China
Manufacturing & Repair.
Tel:+86 312 8648355, Fax:+86 312 8648441
Singapore
Streamer Manufacturing & Repair;
Customer Support.
Tel:+65 64 17 70 00, Fax:+65 6 545 1418
April 11, 2013 3
428XL Users Manual Vol. 1
In no event shall SERCEL be liable for incidental or consequential damages or related expenses
resulting from the use of this product, or arising out of or related to this manual or the information
contained in it, even if SERCEL has been advised, or knew or should have known of the possibility of
such damages.
The information included in this documentation is believed to be accurate and reliable. However,
SERCEL reserves the right to make changes to its products or specifications at any time, without notice,
in order to improve design or performance and to supply the best possible product. This documentation
does not form in any way a contractual agreement of sales promise on the part of SERCEL.
Software mentioned in this documentation is sold under a precise licence agreement and as such the
documentation may cover technical areas for which the user may not have a final licence.
No part of this documentation, or any of the information included herein may be modified or copied in
any form or by any means without the prior written consent of SERCEL.
2005 Sercel. All Rights Reserved.
Printed in France.
Sercel, 428XL, 428XLS, AIB, DPG, DSD, DSU1, DSU3, DSU3-428, e-428, eSQC Pro, FDPA428, FDU,
FDU-428, HSU, LandPro Bin, LAUL, LAUL-428, LAULS, LAUX, LAUX-428, LAUXS, Link, LL428,
LLIU, LLX400, LRU, LSI, LSS, LT428, LX, MGA, MRU, MSI, QT428, SGA, TMS428, TMU428, VE432,
VE464, VQC88, WPSR are all trademarks of Sercel. All rights reserved.
DSUGPS: US Patent 7,117,094 B2.
UNIX is either a registered trademark or trademark of The Open Group in the United States and/or other
countries.Microsoft and Windows are either registered trademarks or trademarks of Microsoft
Corporation in the United States and/or other countries. Other product and company names mentioned
herein may be the trademarks of their respective owners.
Printed on 100% recycled paper
using vegetable-oil based ink
4 April 11, 2013
428XL Users Manual Vol. 1
Warnings, Cautions, Important Notices, and Notes
Warnings, Cautions, and Important notices throughout this manual
guide you to avoid injury, prevent equipment damage, and determine
equipment use when varying components or configurations exist. Notes
provide tips or additional information.
SERCEL is not responsible for damages or injuries that result from
failure to observe the information provided.
Warnings and Cautions
WARNING
When a Warning or Caution appears with a lightning-bolt icon, as
shown in this example, this is to indicate a potential hazard that may
lead to bodily injury or even death.
CAUTION
When a Warning or Caution appears with an exclamation-point icon, as
shown in this example, this is to indicate possible equipment damage or
potential risk of misuse and incorrect operation.
Important Notices
IMPORTANT
Important notices appear in the manual to highlight information that
does not affect the risk of bodily injury, death, or equipment damage,
but is nevertheless important. These notices appear with a stop-sign
icon, as shown in this example.
Notes
Note Notes provide tips or peripheral facts and may guide you to
other sources of information.
April 11, 2013 5
428XL Users Manual Vol. 1
Revision history
Date of
revision
Chapters or
pages
affected
Description of revision or reason for change
Nov. 2005 V 1.0 release
Oct. 2006 p. 400, 401 Updated information on raw data.
Dec. 2006 V 2.0 release.
Mar. 2007 p. 678 VE432 Status code 11.
J une 2007 p. 396 Updated description of correlation.
Dec. 2007
Chap. 6
Chap. 9
Chap. 14
V 3.0
- Simultaneous sources, Micro-seismic, Noise Editing
(Enhanced Diversity).
- VE464.
- Open Vibrator Controller.
J an. 2008 p. 216
p. 394
p. 557
- Added Pulse test.
- Updated Enhanced Diversity noise editing.
- Reviewed VE464 Update function.
Feb. 2008 p. 261, 265 Misprints (correct keywords are correlWith and addPi-
lot).
Mar. 2008 p. 348, 361 Tutorial for SQC Dump mode.
J une 2008 p. 97
p. 110
p. 573
- Reviewed Swath setup.
- Collapse survey gaps option.
- Exporting result log files via the Web server.
Aug. 2008 p. 316 Reviewed LSS operating instructions.
Sep. 2008 p. 242 Adjusting T0 shift (Line Download setup).
Feb. 2009 V4.0
Oct. 2009 p. 69
p. 281, 326
p. 343
p. 565
- Server Id.
- Dynamic fleet grouping.
- Minimum distance between slip-sweep fleets.
- DSD status 11.
Nov. 2009 p. 383
p. 539
- Ready message format.
- Fleet function in Auto mode.
Mar. 2010 p. 182 Updated FDU-to-FDU2S cabling.
6 April 11, 2013
428XL Users Manual Vol. 1
Date of
revision
Chapters or
pages
affected
Description of revision or reason for change
Dec. 2009 p. 97, 465
p. 147, 169,
175, 432,
586,
- Exporting multiple swaths to distinct directories on
NFS disks.
- DSUGPS.
J an. 2010 p. 282
p. 373
p. 564, 565
- Autonomous mode (enabling).
- Autonomous mode (description).
- DPG and DSD status code 25 (Overrun error).
May 2010 p. 169, 413 Projection type and DSUGPS.
Aug. 2010 p. 312 Reviewed LSS FO/TB delay calibration procedure.
Sep. 2010 p. 242 Adjusting the T0 shift.
Nov. 2010 Release5.0.
Feb. 2011 p. 67
p. 151
- Unmanned option (patch03, patch06).
- Disruption along Transverse requires Field Off/On.
J une 27, 2011 p. 122 Right-click on selection button gets traceability for the
whole selection.
Sep. 6, 2011 p. 74
p. 175 - 177
- NAS type option.
- DSUGPS Instrument view and Numeric view.
Dec. 22, 2011 p. 69
p. 166
- Licences codes.
- Marking DSU3-428 line segments.
May 16, 2012
p. 74
p. 155, 180
p. 285, 295,
345
p. 487
Patch14.
- Max number of NFS servers.
- cs Sensor Type (skipped channel) not compatible
with FDU2S.
- Dynamic slip-sweep mode.
- Virtual NAS.
J une 26, 2012 p. 125 QC bar charts (bar straddling limit marker).
Aug. 7, 2012 p. 430 Go To Waypoint by drag&drop from jPositioning.
Aug. 7, 2012 p. 330 Priority criteria in dynamic fleet grouping.
April 11, 2013 7
428XL Users Manual Vol. 1
Date of
revision
Chapters or
pages
affected
Description of revision or reason for change
Nov. 27, 2012
p. 71
p. 109
p. 249
p. 288
p. 407
p. 467
p. 502
Patch 17.
- OVC licence.
- Preferences setup in jLine.
- Ready status management.
- Reshoot dialogue option.
- Enable/Disable TDMA tracking in jPositioning.
- Files per Tape (max. 1000000).
- Ti, Tj (ms).
Feb. 21, 2013
p. 114
p. 169
Patch 19.
- LAUX-G with attached GPS receiver in Instrument
view.
Patch 21
- Azimuth & Position Accuracy setup.
Mar. 21, 2013 p. 409 Datum Scale Factor stands for Scale Difference.
Apr. 11, 2013
p. 164
Patch 22.
- DSUGPS.
8 April 11, 2013
428XL Users Manual Vol. 1
428XL Users Manual Vol. 1 9
April 11, 2013
Table
of
Contents
Revision history . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
1 Introduction
About the 428XL documentation. . . . . . . . . . . . . . . . . . . . . . . . . . .24
Terminology and conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
Working with 428XL windows . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
Dialog boxes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
Views . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35
Bar charts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37
2 Getting started
Opening a user session . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40
Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40
Application Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42
Server Administration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44
The server Administration window . . . . . . . . . . . . . . . . . . . . . .44
Registering a new user . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45
Session manager . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47
Licence information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48
Starting/stopping the 428XL server . . . . . . . . . . . . . . . . . . . . . .49
The launcher bar. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50
Hands-on guide. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52
Table of Contents
10 428XL Users Manual Vol. 1
April 11, 2013
System status archive tool (File Packager). . . . . . . . . . . . . . . . . . . .60
The crews Web site. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .61
The Chat tool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .64
3 Installation setup
Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .66
Seismic recording instrumentation. . . . . . . . . . . . . . . . . . . . . . . . . .67
Peripherals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .72
Export mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .74
Mobile Receiver Unit (MRU). . . . . . . . . . . . . . . . . . . . . . . . . . . . . .76
428XL scalability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .77
Master/Slave. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .79
Unmanned. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .81
4 Configuration
The main window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .84
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .84
Customer Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .85
Copyrights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .85
Identity Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .86
The Setup menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .88
Crew setup window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .88
User Info setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .92
SEGD setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .92
Disk Record setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .95
Swath setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .97
On Line/Off Line . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .100
5 Line
The main window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .104
Topographic views . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .107
Table of Contents
428XL Users Manual Vol. 1 11
April 11, 2013
About topographic views . . . . . . . . . . . . . . . . . . . . . . . . . . . . .107
Sensor view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .111
Instrument view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .113
Battery view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .115
Seismonitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .116
Working with graphic views . . . . . . . . . . . . . . . . . . . . . . . . . .117
Numeric views . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .123
Histogram view. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .125
The Survey setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .127
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .127
Survey . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .128
Point Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .130
Sensor type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .131
The Layout setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .134
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .134
Markers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .135
Auxiliary channels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .139
Detour . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .141
Mute channels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .144
The Spread Type setup. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .145
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .145
Absolute spreads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .146
Generic spreads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .148
The Look setup. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .151
LAU Leakage setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .153
Advanced layouts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .155
Skipped channels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .155
Logical line mapped with several physical lines . . . . . . . . . . .157
Detour with skipped receiver points . . . . . . . . . . . . . . . . . . . .159
Snaking layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .160
Table of Contents
12 428XL Users Manual Vol. 1
April 11, 2013
Working with DSU3-428 & DSUGPS links . . . . . . . . . . . . . . . . .162
DSU3-428 topology . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .162
Acquisition using DSU3 channels . . . . . . . . . . . . . . . . . . . . . .163
DSU3-428 in the Survey Setup . . . . . . . . . . . . . . . . . . . . . . . .164
DSU3-428 in the Layout Setup . . . . . . . . . . . . . . . . . . . . . . . .166
DSU3 in the Spread Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . .167
DSU3 in the Test Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .168
DSUGPS Setup menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .169
DSUGPS firmware upgrading . . . . . . . . . . . . . . . . . . . . . . . . .171
DSU Form Line function . . . . . . . . . . . . . . . . . . . . . . . . . . . . .174
DSU Sensor view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .174
DSU Instrument view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .175
DSU Numeric view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .177
DSU Seismonitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .178
DSU3 tilt correction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .179
Working with ULS field equipment. . . . . . . . . . . . . . . . . . . . . . . .180
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .180
Deployment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .181
Survey setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .183
Marker setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .184
Detour setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .189
Auxiliary channel setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .197
Test setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .197
Checkline . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .197
Radio telemetry. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .198
Radio telemetry equipment . . . . . . . . . . . . . . . . . . . . . . . . . . .198
Instrument Topographic view . . . . . . . . . . . . . . . . . . . . . . . . .199
The Radio QC Limit setup . . . . . . . . . . . . . . . . . . . . . . . . . . . .200
Frequency management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .201
Table of Contents
428XL Users Manual Vol. 1 13
April 11, 2013
LRU parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .208
LAUR parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .213
Wakeup/Sleep . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .213
Loop test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .214
Test functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .215
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .215
Instrument tests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .218
Sensor tests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .221
Multiple tests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .224
Seismonitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .225
The Form Line setup. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .226
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .226
Line Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .227
Network Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .229
The Synthetic setup. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .231
The Download setup. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .237
6 Operation
The Main Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .244
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .244
The Operation Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .246
The Active Source view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .248
The Active Acquisition view . . . . . . . . . . . . . . . . . . . . . . . . . .254
The Operation Report view . . . . . . . . . . . . . . . . . . . . . . . . . . .255
The Process Type setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .256
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .256
Auxiliary traces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .263
Impulsive type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .266
Impulsive Stack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .267
Correlation Before Stack . . . . . . . . . . . . . . . . . . . . . . . . . . . . .268
Table of Contents
14 428XL Users Manual Vol. 1
April 11, 2013
Correlation After Stack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .270
Vibroseismic Stack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .272
How to Generate a Process Type . . . . . . . . . . . . . . . . . . . . . . .274
The Source Point Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .275
Source point parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .275
To generate a Source Point setup . . . . . . . . . . . . . . . . . . . . . .280
Seismic setup options. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .281
Operating Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .281
Automation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .282
Slip-Sweep . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .284
Dynamic Fleet Grouping . . . . . . . . . . . . . . . . . . . . . . . . . . . . .286
Guidance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .286
Look option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .287
Reshot option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .288
The Source Type setup. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .289
Sources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .289
Explosive source parameters . . . . . . . . . . . . . . . . . . . . . . . . . .290
Vibroseismic source parameters . . . . . . . . . . . . . . . . . . . . . . .291
The Delay setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .295
The Noise Editing setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .297
Noise editing parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . .297
Noise editing thresholds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .302
The Observers Comment Type Setup. . . . . . . . . . . . . . . . . . . . . .304
How to take shots or sweeps. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .305
Blaster shots . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .305
VE432 or VE464 sweeps . . . . . . . . . . . . . . . . . . . . . . . . . . . . .307
Navigation-driven shooting . . . . . . . . . . . . . . . . . . . . . . . . . . .309
Multiswath . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .310
Shooting with an LSS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .311
Table of Contents
428XL Users Manual Vol. 1 15
April 11, 2013
Flip-Flop sweeps. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .321
Simultaneous sources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .326
Manual clustering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .327
Dynamic Fleet grouping . . . . . . . . . . . . . . . . . . . . . . . . . . . . .329
Slip-sweep. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .334
Theory of operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .334
How to implement slip-sweep . . . . . . . . . . . . . . . . . . . . . . . . .336
Standard Slip-Sweep mode . . . . . . . . . . . . . . . . . . . . . . . . . . .339
Allowable minimum distance between simultaneous sources .343
Dynamic Slip-Sweep mode . . . . . . . . . . . . . . . . . . . . . . . . . . .345
SQC Dump mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .348
SQC Dump mode with VE464 . . . . . . . . . . . . . . . . . . . . . . . .348
SQC Dump mode with VE432 . . . . . . . . . . . . . . . . . . . . . . . .361
Micro-seismic. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .371
Autonomous mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .373
Vibrator Guidance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .378
How to use the Vibrator Guidance option . . . . . . . . . . . . . . . .378
The Go To Waypoint command . . . . . . . . . . . . . . . . . . . . . . .379
Multi-gun Shallow-water shooting mode. . . . . . . . . . . . . . . . . . . .381
Master/Slave operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .384
More About Noise Elimination . . . . . . . . . . . . . . . . . . . . . . . . . . .388
Spike Editing method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .388
Diversity Stack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .391
Enhanced Diversity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .393
More About Correlation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .396
Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .396
Data Distribution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .398
7 Positioning
The main window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .404
Table of Contents
16 428XL Users Manual Vol. 1
April 11, 2013
The Setup menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .408
The Datum Type setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .408
The Projection Type setup . . . . . . . . . . . . . . . . . . . . . . . . . . . .411
Quality Warning setup window . . . . . . . . . . . . . . . . . . . . . . . .413
The Vehicle Identity setup . . . . . . . . . . . . . . . . . . . . . . . . . . . .416
The geographical view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .418
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .418
The layer manager . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .422
Background . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .423
GeoZones . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .425
Swath . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .426
Miscellaneous . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .428
Vehicles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .429
Sources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .430
Line devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .432
The Tracking view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .434
Graphical tracking view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .434
Numerical tracking view . . . . . . . . . . . . . . . . . . . . . . . . . . . . .437
More about the estimated COG position . . . . . . . . . . . . . . . . .437
Vehicles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .439
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .439
Supported vehicle tracking systems . . . . . . . . . . . . . . . . . . . . .440
Customizing tracked vehicles . . . . . . . . . . . . . . . . . . . . . . . . .442
Vehicle trackline and history file . . . . . . . . . . . . . . . . . . . . . . .443
The Alert system. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .444
Emergency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .444
GeoZone perimeter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .445
Global alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .446
Excess speed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .448
Table of Contents
428XL Users Manual Vol. 1 17
April 11, 2013
Working with the GIS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .450
Object labelling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .450
Attribute colour maps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .451
Query builder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .453
Coord converter tool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .455
Basic Geodesy Glossary. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .456
8 Export
The main window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .458
File export controls. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .460
Export device indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . .460
Auto/Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .462
The Tape Setup menu. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .465
The Functions menu. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .468
NFS disk . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .468
FTP server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .469
Tape . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .470
Get Device Info . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .472
Playback . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .472
Copy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .475
Reinit Export . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .476
Recorder activity logs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .477
Exporting to NAS disks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .481
Copying exported files . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .486
Exporting to a virtual NAS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .487
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .487
Virtual NAS Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .488
NFS mount function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .490
Virtual NAS status indicator . . . . . . . . . . . . . . . . . . . . . . . . . .490
Auto/Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .491
Table of Contents
18 428XL Users Manual Vol. 1
April 11, 2013
Working with tape drives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .492
Disk space monitoring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .493
9 VE464
The main window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .496
The Vibrator Crew setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .498
The Basic Type setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .501
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .501
Linear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .503
dB/Hz Log, Tn and dB/Octave Log . . . . . . . . . . . . . . . . . . . . .504
Random . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .509
Custom . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .510
Dedicated . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .512
Pulse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .513
Delay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .514
Compound . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .515
The Deboost option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .516
The Numeric Pilot option . . . . . . . . . . . . . . . . . . . . . . . . . . .516
Generating a Basic Type setup . . . . . . . . . . . . . . . . . . . . . . . .517
The Acquisition Type setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .518
The Radio Management setup . . . . . . . . . . . . . . . . . . . . . . . . . . . .522
TDMA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .522
TracsTDMA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .523
Raveon . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .526
Analog radio . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .528
The QC Limit setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .529
The Sweep Management setup. . . . . . . . . . . . . . . . . . . . . . . . . . . .530
The Pattern setup window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .532
Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .536
Auto/Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .536
Table of Contents
428XL Users Manual Vol. 1 19
April 11, 2013
Vibrator Fleet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .537
Set DSD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .541
Get DSD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .543
Set Servo . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .545
Update Custom . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .548
Ready . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .550
Local Acquisition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .552
Set Config . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .553
Set Guidance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .554
Get Similarities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .555
Update Version . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .557
Normal acquisition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .558
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .558
Graphic view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .559
Numeric view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .562
DPG/DSD status codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .564
Statistics views . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .566
10 Log
The main window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .570
Editing/saving/loading 428XL parameters. . . . . . . . . . . . . . . . . . .576
The Shooting setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .578
SPS files . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .581
The SPS format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .581
Importing an SPS file . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .583
Exporting an SPS file . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .585
Operator reports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .587
Observer Logs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .587
APS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .589
APS Verbose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .589
Table of Contents
20 428XL Users Manual Vol. 1
April 11, 2013
Source COG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .589
Receiver position history data . . . . . . . . . . . . . . . . . . . . . . . . .590
Event log. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .591
11 Plotter
The main window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .594
The Banner setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .597
Selecting the traces to plot . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .603
Plot parameters for production shots . . . . . . . . . . . . . . . . . . . . . . .606
Processing setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .606
Rendering setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .610
Format setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .610
Test records. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .613
12 VE432
The main window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .616
The Vibrator Crew setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .618
The Basic Type setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .621
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .621
Linear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .623
dB/Hz Log, Tn and dB/Octave Log . . . . . . . . . . . . . . . . . . . . .624
Pulse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .629
Random . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .630
Custom . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .631
Compound . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .634
Delay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .635
Deboost option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .635
Generating a Basic Type setup . . . . . . . . . . . . . . . . . . . . . . . .636
The Acquisition Type setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .637
The Radio Management setup . . . . . . . . . . . . . . . . . . . . . . . . . . . .641
The QC Limit setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .644
Table of Contents
428XL Users Manual Vol. 1 21
April 11, 2013
The QC Choice setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .645
The T0 Time setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .646
The Pattern setup window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .648
Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .652
Auto/Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .652
Look . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .653
Vibrator Fleet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .655
Local Acquisition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .657
Set DSD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .658
Get DSD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .659
Radio functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .662
Set Servo . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .667
PCMCIA Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .669
Normal acquisition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .672
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .672
Graphic view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .673
Numeric view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .676
DPG/DSD status codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .678
Statistics views . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .679
13 Other vibrator electronics
The main window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .682
Working with other vibrator electronics. . . . . . . . . . . . . . . . . . . . .684
14 Open Vibrator Controller
The main window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .686
The Vibrator Crew setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .687
The Acquisition Type setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .688
The QC Limit setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .690
The Vibrator Fleet setup. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .691
Normal acquisition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .692
Table of Contents
22 428XL Users Manual Vol. 1
April 11, 2013
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .692
Graphic view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .692
Numeric view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .694
Statistics views . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .696
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 699
428XL Users Manual Vol. 1 23
April 11, 2013
Chapter
1 Introduction
This chapter includes the following sections:
About the 428XL documentation (page 24)
Terminology and conventions (page 26)
Working with 428XL windows (page 30)
Introduction
About the 428XL documentation >
24 428XL Users Manual Vol. 1
April 11, 2013
1
About the 428XL documentation
The documentation coming with the 428XL system consists of the
following manuals:
Installation Manual (0311428): contains an introduction to the
428XL system, installation information, a few instructions for the
operator to get started, and reference information that will help you
select a 428XL configuration tailored to your needs.
Users Manual Volume 1 (0311430): this manual, describing the
parameters displayed on the systems Graphic User Interface (GUI)
and how to use each window.
Users Manual Volume 2 (0311431): contains information on logged
data and on interfaces (description of Input/Output formats, including
the SEGD format).
Users Manual Volume 3 (0311432): contains reference information
(filter charts, theory of tests, technical data, release notes,
specifications).
Technical Manual (0311429): contains maintenance and repair
information, including operating instructions for using the systems
testers.
Before using this manual, you need to install the system by following
the instructions given in the 428XL Installation Manual.
The Users Manual is automatically loaded from the 428XL CDROM
to your computers disk as you load the 428XL software package. Then
it is just one click away at all times, using the Help button available in
every main window. With a PDF file reader (Adobe Acrobat Reader) on
a computer you can view this manual direct from the 428XL CDROMs
DOC directory.
This manual assumes you are familiar with window-driven systems and
you know how to work with windows, including how to use a mouse
and standard menus and commands, and to open, move, resize, shrink,
restore and close a window.
Introduction
About the 428XL documentation >
428XL Users Manual Vol. 1 25
April 11, 2013
1
To start the server, if required, see Starting/stopping the 428XL server on
page 49
To launch the 428XL Graphic User Interface, see Opening a user
session (page 40).
Introduction
Terminology and conventions >
26 428XL Users Manual Vol. 1
April 11, 2013
1
Terminology and conventions
To use this manual, you need to be familiar with a number of terms that
are described below.
Figure 1-1 Dialog box
Click
To press and release a mouse button quickly (left-hand button, unless
otherwise specified).
Command button
A pushbutton that carries out a command (Add, Change, Delete,
Reverse) with the parameters displayed in the text boxes.
Dialog box
A secondary window that provides or requests information within a
main window.
Double-click
To press and release the left-hand mouse button twice in rapid
succession without moving the mouse.
Drag
To move an item on the screen by holding down the mouse button while
moving the mouse. See Drag and Drop (page 37).
List box
Index box
Text box
Scrollbar
Pushbutton
Introduction
Terminology and conventions >
428XL Users Manual Vol. 1 27
April 11, 2013
1
Icon
A small graphical image used to represent a window. Windows can be
turned into icons or minimized to save room or unclutter the workspace.
Index box
A text box (usually the first box from left to right) showing the
identification number of a row (or set of rows) to be generated in a list
box or selected from a list box.
List box
A box used to display a scrollable list of the rows edited under a text
box.
Mouse buttons
The left-hand button is used to click, double-click, and select an item.
The right-hand button causes a contextual menu to pop up, if any is
available.
Option button
A pushbutton used to post an option menu in which you can select an
option. An option button displays the label of the selected option and a
bar graphic to distinguish it from a command button.
Figure 1-2 Option button
Click to show
available options
Introduction
Terminology and conventions >
28 428XL Users Manual Vol. 1
April 11, 2013
1
Point (to)
To move the mouse pointer on the screen until it rests on the item you
want to select.
Scale
A rectangular box, with a slider in it, used to set or display a value in a
range. A label indicates the current value. A value is selected by
dragging the slider and releasing the mouse button when the desired
value is displayed. Clicking on either side of the slider selects the next
higher or lower value.
Figure 1-3
Scrollbar
A rectangular box, with a slider and direction arrow graphics in it, used
to scroll the visible area of a window pane or box (see Figure 1-1 on
page 26). The slider indicates the relative position and size of the visible
area. The position is adjusted by dragging the slider or clicking the
direction arrows.
Select
To point to an item in a menu, by dragging the mouse pointer until the
item is highlighted, and release the mouse button.
Text box
An entry box used to enter or display values and/or text for a parameter
within a dialog box (see Figure 1-1 on page 26).
Current setting
Slider
Scale
Introduction
Terminology and conventions >
428XL Users Manual Vol. 1 29
April 11, 2013
1
Toggle button
A pushbutton composed of a label preceded by a graphic (circle or
square) with two distinctive states that indicate the set and unset states
of the button.
There are two special cases of toggle buttons.
Radio button: used to select one option from a number of options.
Each option is represented by a radio button. Each button represents
a mutually exclusive selection (only one radio button can be set at a
time).
Figure 1-4
Check button: used to set a number of options. Unlike a radio button,
any number of check buttons can be set at the same time.
Figure 1-5
Vib. 1
Vib. 2
Vib. 3
Radio buttons
Check buttons
Check buttons
Introduction
Working with 428XL windows > Dialog boxes
30 428XL Users Manual Vol. 1
April 11, 2013
1
Working with 428XL windows
Dialog boxes
Conventions used in this section
The following conventions are used in this section:
m, n, o, p: stand for sequential numbers.
i: stands for an increment (positive or negative); the +sign is optional.
v: stands for any allowable value for a parameter.
All other symbols are part of the syntax.
General rules
Clicking in a text box causes the text cursor (I-beam pointer) to
appear in it, allowing you to type the desired information. To make
corrections, use the BACKSPACE or DELETE key as applicable.
The CARRIAGE RETURN key is only used to enter two or more text
lines into the same text box,
In any dialog box, the allowable values for each text box will
automatically show up if you click Add (or Apply if there is no Add
button) whenever the text box is blank.
Double-clicking in a text box causes its content to be highlighted.
Then, pressing any key erases the content and enters the
corresponding character.
Clicking on any row in a list box selects the row (its number shows
up in the index box). See the example below.
Double-clicking on any row in a list box selects the row and causes
the content of the row to show up in the associated text boxes. See the
example below.
Example: Assuming three rows in a list box, with the following content:
Introduction
Working with 428XL windows > Dialog boxes
428XL Users Manual Vol. 1 31
April 11, 2013
1
Figure 1-6
1. Double-clicking in the second row causes its content to appear in
the text boxes:
Figure 1-7
2. Clicking in the third row selects it and causes the row number (3)
to appear in the index box:
Figure 1-8
Text box 2 Text box 1
1 11
2 21
3 31
Content
Index box Text box 1 Text box 2
1 11 12
2 21 22
3 31 32
Text box 2 Text box 1
1 11
2 21
3 31
2 21 22
Double-click
Text box 2 Text box 1
1 11
2 21
3 31
3 21 22
Click
Introduction
Working with 428XL windows > Dialog boxes
32 428XL Users Manual Vol. 1
April 11, 2013
1
3. Clicking on the Change button updates the third row with the
content of the text boxes:
Figure 1-9
In an index box
m-n: selects all rows from row m to row n.
m-: selects all rows from row m to the end of the list.
-m: selects all rows from the beginning of the list to row m.
-: selects the whole list.
m-n/i: selects rows m, m+i, m+2i, m+3i...n
n-m/-i: selects rows n, n-i, n-2i, m-3i...m
In a text box
/: means the current value in the list box will not be changed.
V: means the value V will be applied to the specified row or set of
rows.
V/i or V/+i (or V/-i): means an incremental (or decremental) value
starting from V will be applied to the specified set of rows. (The +
sign is optional).
/i or /+i (or /-i): means an increment (or decrement) will be applied to
the pre-existing values of the specified set of rows.
Text box 2 Text box 1
1 11
2 21
3 21
3 21 22
Click
Content
Index box Text box 1 Text box 2
1 11 12
2 21 22
3 21 22
Introduction
Working with 428XL windows > Dialog boxes
428XL Users Manual Vol. 1 33
April 11, 2013
1
Add button
Used to create a row or set of rows. You have to enter the new row
numbers in the index box, using the syntax shown in the examples
below (this will not work if the rows already exist in the list box).
1: creates row #1 in the list box.
1-5: creates rows #1, 2, 3, 4, 5.
1-8/2: creates rows #1, 3, 5, 7.
7-2/-2: creates rows #7, 5, 3.
Change button
Used to update a row or set of rows (already existing in the list box) with
the content of one or more text boxes. You have to enter the number of
the row (or the range of rows) to update in the index box, using the
syntax shown in the examples below:
1: updates row #1.
1-5: updates rows #1 through 5.
5-: updates all rows from #5 to the end of the list.
-5: updates all rows from the first sequential number in the list to #5.
-: updates the whole list.
Assuming the list box contains rows #10, 20, 8, 11, 12, 15, 30 (starting
with 10 and ending with 30):
-/2: updates rows #10, 8, 12, 30.
10-15/2: updates rows #10, 8, 12.
20-/2: updates rows #20, 11, 15.
-15/2: updates rows #10, 8, 12.
Introduction
Working with 428XL windows > Dialog boxes
34 428XL Users Manual Vol. 1
April 11, 2013
1
Delete button
Used to delete a row or set of rows from the list box. You have to enter
the number of the row (or the range of rows) to delete in the index box,
using the syntax shown in the examples below:
1: deletes row #1.
1-5: deletes row #1 through 5.
5-: deletes all rows from #5 to the end of the list.
-5: deletes all rows from the first sequential number in the list to #5.
-: deletes the whole list.
Reverse button
Used to reverse the order of a set of rows specified in the index box as
shown in the examples below:
Apply button
Saves and/or activates the selections made in a main window or a dialog
box. If you wish to generate a file containing the parameters currently
displayed, use the Log main window.
Reset button
Restores the latest values that was saved in the list box when the Apply
button was last used.
Index box
List box
before clicking Reverse
List box
after clicking Reverse
1-5
3-
-3
-
1 2 3 4 5
1 2 3 4 5
1 2 3 4 5
1 2 3 4 5
5 4 3 2 1
1 2 5 4 3
3 2 1 4 5
5 4 3 2 1
Introduction
Working with 428XL windows > Views
428XL Users Manual Vol. 1 35
April 11, 2013
1
Views
Selecting text
You can copy content from a text box to another text box or to a text
editor. To select the text to copy, do the following:
1. With the mouse left button, click before the first character to select
(release the mouse button).
2. Using the scrollbar, scroll through the text until the last character
to select is visible.
3. Press the Shift key and hold it down.
4. With the mouse left button, click on the last character to select.
5. Release the Shift key. As a result, the selected text is highlighted.
Alternately, if all of the text to select is viewed, you can do as follows:
1. Move the mouse pointer to the first character to select.
2. Press the mouse left button and hold it down.
3. Move the mouse pointer to the last character to select.
4. Release the mouse button. As a result, the selected text is
highlighted.
Selecting table rows
You can copy content from a table in a numeric view to a text editor or
to a spreadsheet tool. To select the tables cells to copy, do the following:
1. Click in the first row to select.
2. Press the Shift key.
3. Click in the last row to select. As a result, the selected rows are
highlighted.
Introduction
Working with 428XL windows > Views
36 428XL Users Manual Vol. 1
April 11, 2013
1
Selecting a graphical area
You can copy content from a graphic view to a setup window. To select
the objects to copy, do the following:
1. Move the mouse pointer to one (e. g. upper-left) corner of the area
to select.
2. Press the mouse centre button and hold it down.
3. Still holding down the mouse button, move the mouse pointer to
the opposite (e. g. lower-right) corner of the area to select.
4. Release the mouse button. As a result, the selected area is
highlighted.
Copy And Paste
The Copy and Paste function allows you to copy content from a dialog
box to another.
1. Select the text, or table cells, or objects to copy:
- To select content from a text box, see Selecting text (page 35);
- To select content from a table, see Selecting table rows (page 35);
- To select content from a graphic view, see Selecting a graphical
area (page 36).
2. Copy the selected content as follows:
- press both Ctrl and C on the keyboard (press Ctrl first).
- or choose Copy from the Edit menu if any.
3. Click in the destination text box, or setup window, or application.
4. Paste the selected content as follows:
- press both Ctrl and V on the keyboard (press Ctrl first).
- or choose Paste from the Edit menu if any.
Introduction
Working with 428XL windows > Bar charts
428XL Users Manual Vol. 1 37
April 11, 2013
1
Drag and Drop
In some windows, you can drag and drop graphical objects from a
panel to another, by doing the following:
1. Press the Ctrl key and hold it down;
2. Left-click on the object to select, and hold down the mouse
button;
3. Still holding down the Ctrl key and mouse button, move the
mouse pointer to the desired location;
4. Release the mouse button and Ctrl key.
Bar charts
Figure 1-10
On each chart the horizontal axis is the scale (divided into a number of
bins) for the values to display, and the vertical axis is for the number of
values in each bin. The following values are also shown:
You can zoom in by double-clicking on the bar chart, and zoom out by
double-clicking again on it.
With the mouse pointer resting anywhere on a bar chart, pressing the
mouse right button causes a menu to pop up with three commands.
Show curve
Used to show or hide the Gaussian curve.
Introduction
Working with 428XL windows > Bar charts
38 428XL Users Manual Vol. 1
April 11, 2013
1
Show grid
Used to show or hide the plot grid.
Properties
Number of bars: This field is used to specify the number of bins you
want to generate in the bar chart.
Bar labels: This option button is used to select the type of annotation
to be displayed above each bar:
- Percentage of values contained in the bin, with respect to the
whole set of values.
- Number of values contained in the bin.
428XL Users Manual Vol. 1 39
April 11, 2013
Chapter
2 Getting started
This chapter is intended for beginners. It describes how to
use the crews Server Administration window and Web site,
and briefly teaches a local or remote user how to get
started. This chapter includes the following sections:
Opening a user session (page 40)
Server Administration (page 44)
The launcher bar (page 50)
Hands-on guide (page 52)
System status archive tool (File Packager) (page 60)
The crews Web site (page 61)
The Chat tool (page 64)
Getting started
Opening a user session > Connection
40 428XL Users Manual Vol. 1
April 11, 2013
2
Opening a user session
To open a user session:
- Double-click on the 428XL Client icon on your
desktop.
- Wait until the launcher bar appears.
All icons in the launcher bar (except the connection icon and the Help
button) are dimmed until you get connected.
Right-clicking on the Connection icon causes a menu
to pop up, prompting the following commands:
Connection: used to log on to the server. See
Connection (page 40).
Settings: see Application Settings (page 42).
Packager: system status archive tool (see page 60).
Exit: used to close the 428XL Client application.
Connection
This command is selected by default on a left-click on the connection
icon in the launcher bar. It opens a connection window:
Figure 2-2
Advanced Parameters
If your machine uses a Proxy server, click on the Advanced
Parameters tab to set the Proxy configuration.
Figure 2-1
Launcher bar
Click here
to connect
Getting started
Opening a user session > Connection
428XL Users Manual Vol. 1 41
April 11, 2013
2
Choose Enabled, then enter the same configuration (Host name and
Port) as in your Web browser (see the Internet connection options in
your browser).
Remote Server
To connect to the server, click on the Remote Server tab, then do the
following:
Figure 2-3
1. Choose the type of connection: Local user if you are opening a
user session on the server computer itself or your PC is attached to
the crews local network (172.27.128.x), Remote user
otherwise.
2. The Label field is used to enter a name for your connection
profile. Choose a name that will clearly identify your connection
profile (e. g. your name plus the products name).
3. In the URL field, type the desired crew address, for example:
- localhost if you are connecting as Local user on the server
computer itself, or 172.27.128.1 if you are connecting as an extra
Local user.
- http://nnn.nnn.nnn.nnn if you are connecting as an Intranet or
Internet Remote user, nnn.nnn.nnn.nnn being the IP address
of the nearest Seismic Gateway (depending on which Seismic
Gateway computer is visible to your computer). If you know the
machine name, you can use it in place of the IP address.
1
2
3
4
5
428GUI
428GUI
observer
pwd
Getting started
Opening a user session > Application Settings
42 428XL Users Manual Vol. 1
April 11, 2013
2
4. In the Login and Password fields, type your Login name and
password respectively (supplied to you by the Senior Observer).
5. Click Connect. The 428XL launcher bar icons on your desktop
should not be dimmed anymore.
Application Settings
Figure 2-4
Browser settings
Allows you to choose which Web Browser to use. Only the default
option is prompted (e. g. Internet Explorer on a Windows host
computer, FireFox on a Linux host), unless you have installed another
browser.
Regional settings
Allows you to choose the Help language (English/Chinese/Russian/
Spanish).
Figure 2-5
Getting started
Opening a user session > Application Settings
428XL Users Manual Vol. 1 43
April 11, 2013
2
Desktop
As you close the 428XL application window by selecting Exit from
the connection icon in the launcher bar or clicking the usual close button
in the upper right corner), the system may or may not save the desktop
configuration, depending on which option is enabled in the Desktop
settings window.
Figure 2-6
None: with this option enabled, the default window layout is used
each time you open the 428XL application.
Last session: with this option enabled, the 428XL application opens
with the window layout you were using when you last closed the
launcher bar (with the same user account on the same computer).
Snapshot: with this option enabled, clicking Apply saves the
current window layout on your computer. The windows that were
open at the moment you clicked Apply will automatically open,
with the same window layout, each time you next open the 428XL
application with the same user account on the same computer (until
you change your desktop preference option).
Look&Feel
Used to change the look of windows.
Figure 2-7
Getting started
Server Administration > The server Administration window
44 428XL Users Manual Vol. 1
April 11, 2013
2
Server Administration
In this section:
The server Administration window (page 44)
Registering a new user (page 45)
Session manager (page 47)
Licence information (page 48)
Starting/stopping the 428XL server (page 49)
The server Administration window
Open a user session (see Connection on page 40) unless this is already
done, and click on the administration tool icon in the launcher bar to
open the Administration window.
Figure 2-8
If you log on with Observer privileges, the Administration window
allows you to start/stop the server, manage user sessions, load a patch
from a remote (client) computer. If you log on with Senior Observer
privileges, it also allows you to register users and manage user
passwords.
The Debug tab is only intended for SERCEL customer support
engineers and therefore not described in this manual.
Getting started
Server Administration > Registering a new user
428XL Users Manual Vol. 1 45
April 11, 2013
2
Registering a new user
A new user cannot log on to a crews server unless and until he is
registered on that server. Only a user with Senior Observer role
privileges is allowed to register a remote user.
To register a new user, do the following:
1. Click on the Users tab.
Figure 2-9 Administration window
1. Right-click in the list of profiles and select New from the menu
that pops up.
- In the Name and Password
fields, enter the login name and
password you wish to create for
the new user.
- Click OK. As a result, the new
user appears in the list of
authorized users.
- Choose the desired Password Expiry Date option (either
choose Never or enter the desired expiry date). The Expiry Date
takes effect at 12 a.m. (server local time).
Right-click
Appears only if you log on
with Senior Observer
privileges
Figure 2-10
Getting started
Server Administration > Registering a new user
46 428XL Users Manual Vol. 1
April 11, 2013
2
- From the Role button, choose the privileges you wish to grant to
that user (Guest, or Observer, or Senior Observer permissions).
- Click Apply.
2. Notify the user of the Login name and Password you have created.
Note: After a profile is created, you can change or delete it by right-
clicking on it in the list of profiles and using the menu that pops up.
Role Permissions
Guest
Opening any client window and:
- Viewing the crews parameter settings
(changes are of no effect),
- Viewing results, generating reports;
Website access.
Observer
All Guest role privileges plus the following:
Changing the crews parameter settings.
Session administration.
Changing the installation parameters.
Senior Observer
All Observer role privileges plus the
following:
User administration (registering new users).
Getting started
Server Administration > Session manager
428XL Users Manual Vol. 1 47
April 11, 2013
2
Session manager
Open the Administration window and then click on the Sessions tab.
This displays a session manager view with a navigation pane showing
all opened sessions.
Unless you are logged on to the crews server with Observer or Senior
Observer role privileges, you are not allowed to make any changes in
the session manager window.
Figure 2-11 Session manager
Clicking on any session causes detailed information to be displayed
below the navigation pane.
Right-clicking on any session causes a contextual menu to pop up,
prompting the necessary commands for the management of sessions:
To close a session, right-click on it and select Kill.
Click on session to
show details
Right-click
Details
Getting started
Server Administration > Licence information
48 428XL Users Manual Vol. 1
April 11, 2013
2
Licence information
Open the Administration window and then click on the Licences tab.
This displays information that is not displayed in the Install window
when you enter your licence code (Expiry date, allowed tokens, etc.).
Figure 2-12
Note A message will appear in the Terminal window of the server
computer 24 hours before your software licence expires, but it
is advisable to use the Administration window to check the
expiry date before that.
Getting started
Server Administration > Starting/stopping the 428XL server
428XL Users Manual Vol. 1 49
April 11, 2013
2
Starting/stopping the 428XL server
The 428XL server is started automatically when you power up the
server computer.
If you are logged on to the crews server with Observer or Senior
Observer privileges, you can stop and restart the server, or reboot or
shut down the computer, by using the buttons available from the Server
tab in the administration window.
Restart: closes the server application, restarts it and restores your
connection.
Reboot: reboots the computer and restarts the server application.
Shutdown: closes the server application and turns off the power to
the computer.
Figure 2-13
Getting started
The launcher bar >
50 428XL Users Manual Vol. 1
April 11, 2013
2
The launcher bar
The Installation icon is used to set
installation parameters for the server
computer (licences, number of cards in the
Control Module, attached peripherals, source
controllers, etc.). See Installation setup
(page 65).
The Configuration icon is used to set the
crews basic parameters, provide information
on the hardware and software configuration
of the system, specify how your SEGD files
must be recorded, and enable/disable
communications with the Control Module.
See Configuration (page 83).
The Line icon is used for the management of
the field electronics. See Line (page 103)
The Operation icon is used for the
management of shots. See Operation
(page 243).
The Export icon is used for the management
of your recording media. See Export
(page 457).
The Positioning icon is used for viewing
source points, tracking vehicles, etc. See
Positioning (page 403).
The VE432 or VE464 icon opens the
Graphical User Interface for the vibrator
controller. See VE464 (page 495) or VE432
(page 615).
The Log icon is used to save/load setup
parameters, import/export processing support
Figure 2-14
Launcher bar
Other Vib
Installation
Configuration
Line
Operation
Export
Positioning
Log
Plotter
Website
Help
Administration
Connection
Click to customize
launcher bar
Chat
VE432
VE464
OVC
Getting started
The launcher bar >
428XL Users Manual Vol. 1 51
April 11, 2013
2
(SPS) files, export operator reports, and for the management of all
reports. See Log (page 569).
The Plotter icon is used for monitoring traces on a plotter. See Plotter
(page 593).
The OVC icon opens the Graphical User Interface for the Open
Vibrator Controller. See Open Vibrator Controller (page 685).
The Chat icon allows you to send messages to the users connected to
the server.
The Website allows you to download or upload SPS files, report files,
etc.
The Help icon displays help information (same as the Help menu in
each window).
The Administration icon is intended for a user with Observer or
Senior Observer privileges to register users, manage passwords and
sessions, etc. See Server Administration (page 44).
The launcher bar can be customized:
Figure 2-15
You can have the launcher displayed vertically
or horizontally by double-clicking on its title
bar.
Use the button at the foot of the launcher bar to
choose which icons you want to be visible.
Double-click
Click to customize
launcher bar
Figure 2-16
Getting started
Hands-on guide >
52 428XL Users Manual Vol. 1
April 11, 2013
2
Hands-on guide
This hands-on guide teaches a beginner how to customize a main
window (also referred to as client window) in just a few clicks. The
first time you log on to a 428XL server, each main window in the
Graphical User Interface is configured with a default layout. Then, your
customized window layout is automatically saved on your computer as
you close the client window, and recovered when you next open it.
In most main windows, it is for you to decide how many views to show
and where to place them. The GUI may also let you decide which
information to view, and which type (numerical/graphical) of view you
want for this information. The intent of the procedure below is to give
you a glimpse of what you can do to customize each main window,
using the Line window as an example.
Customizing windows
1. Open the Line main window (click on the Line icon in
the 428XL launcher bar).
2. On the right-hand border of each toolbar is a down arrow
button. Clicking on that button causes a menu to pop up for you to
choose which buttons you would like to show or hide in the
toolbar. (All options are also available from the menu bar).
Figure 2-17 Customizing toolbars
(2) Click to
customize toolbars
(3) Move to dock
elsewhere or to undock
Undocked toolbar
(4) More options
(click to choose)
Menu bar
Getting started
Hands-on guide >
428XL Users Manual Vol. 1 53
April 11, 2013
2
3. Clicking on the left-hand (shaded) border of the toolbar and
holding down the mouse button allows you to move and dock the
toolbar to whichever border you like inside the window. Moving it
outside the window will undock the toolbar (to dock it again,
simply close it by clicking on the button in the upper right corner
of the undocked toolbar).
4. A double-arrow button (>>) appears if more options are available
but the toolbar is too small for all buttons to fit in. Clicking on that
button causes the hidden options to pop up for you to choose
whichever you like.
Figure 2-18 Window resizing
5. The arrow buttons in the corners of a display pane let you
expand or collapse the pane vertically or horizontally.
6. Adjust the width of each display pane by dragging the vertical
border to the left/right. Likewise, to adjust its height by dragging
the horizontal border upward/downward.
7. To show the different views available, use either the View menu
or toolbar buttons. When you choose to add a view, the new view
pane appears below the currently selected pane.
(5) Expand/collapse
vertically
(6) Drag border
to adjust height
(6) Drag border
to adjust width
(5) Expand/collapse
horizontally
Getting started
Hands-on guide >
54 428XL Users Manual Vol. 1
April 11, 2013
2
Figure 2-19 Adding view panes
8. To hide any view pane, click on the close button associated with
its tab.
9. If the pane is not large enough for the whole view to fit in, you can
resize the main window and/or use the available scrollbars.
Figure 2-20 Customizing view panes
In graphical views, you can zoom in by pressing the left mouse
button, moving the mouse, then releasing the button. Use the
zoom control buttons to zoom out or go back to the whole view.
10. Double-clicking on the tab of any view pane either expands or
collapses the view.
(10) Double-click on tab
to expand/collapse view
(9) Horizontal
scrollbar
(9) Vertical
scrollbar
View all
(11 Drag tab
to move view
(8) Click to hide
view
Zoom out
Getting started
Hands-on guide >
428XL Users Manual Vol. 1 55
April 11, 2013
2
11. You can customize the layout of the main window by placing the
different views where you like them: with the mouse pointer
resting on the tab of any view pane, press the left mouse button,
then move the mouse so as to drag the tab to where you would like
the view pane to appear.
Placing tabs side by side will cause the view panes to be cascaded.
Where views are cascaded, you bring any view to the front by
simply clicking on its tab.
Figure 2-21 Moving view tabs
Also, view panes can be tiled vertically and/or horizontally. With
the example shown in Figure 2-21, dragging the tab to (A) will
split the window vertically and place the view into the left-hand
pane. Dragging the tab to (B) will split the window horizontally
and place the view into the bottom pane. Dragging the tab to (C)
will split the window vertically and place the view into the right-
hand pane (see Figure 2-22).
A
B
C
Cascaded views
Getting started
Hands-on guide >
56 428XL Users Manual Vol. 1
April 11, 2013
2
Figure 2-22 Tiled views
12. Double-clicking on the button in the lower right corner or each
main window enables or disables the automatic updating of the
window. That button is green if automatic updating is enabled, red
otherwise. The automatic update option is also available from the
the Preferences Setup menu, which allows you to adjust the
refresh period of the different views. If you are using an Internet
datalink, you may want to decrease the required bandwidth, by
selecting on longer refresh period. If you are connected to the
local network, you can set the refresh period to the minimum.
Figure 2-23 Auto Update Preference setup
13. The blinking of the heartbeat-like indicator at the foot of the
window is indicative of the window being refreshed.
(12) Enable/disable
Automatic Update
Getting started
Hands-on guide >
428XL Users Manual Vol. 1 57
April 11, 2013
2
Figure 2-24 Memory Preference setup
14. The Memory tab in the Preferences Setup is used to show or
hide the memory occupation bargraph at the foot of the window,
indicating the memory size occupied by J ava views. If the
memory is running out, click on the dustbin icon near the bargraph
to scrap unnecessary data and recover memory space.
15. 428XL messages appear in the Status Mail pane at the foot of
the main window. Whether you choose to show or hide that pane,
the orientation of the Mail icon in the toolbar will tell you if any
message is present (the mail icon being raised is indicative of one
or more messages being present). To delete mail messages, right-
click in the Status Mail pane and select Clear Status from the
menu that pops up.
Customizing tables
16. Most tables in numeric views can be customized by right-clicking
on any column heading and selecting Customize from the menu
that pops up.
17. Any heading appearing in bold style in the Displayed columns
list means that you cannot remove that column (but you can move
it using the up or down arrow button).
18. Any heading appearing in bold style and underlined means you
can neither remove nor move the column (it is always entirely
visible and at the same position in the table). All other columns
can be moved or removed.
(13) Heartbeat-like
indicator (14) Memory bar
Getting started
Hands-on guide >
58 428XL Users Manual Vol. 1
April 11, 2013
2
Figure 2-25 Customizing tables
19. Click in either list box to choose which column to show or hide,
then use the double-arrow buttons to move it to the other list box.
20. Use the up or down arrow button to place each column where you
would like it to appear in the table.
21. You can save that table configuration by clicking on Save and
entering a name for it in the dialog box that shows up.
Subsequently, youll simply have to select the desired type of
table from the Select a Preset option button and click Apply to
recover your preferred arrangement of columns at your
convenience.
22. You can also change the order of columns by clicking on a column
heading in the table, then dragging and dropping it where you
would like it to appear (unless you are not allowed to move that
column).
(16) Right-click on
column heading
(17) Bold means
it cannot be removed
(18) Bold and underlined
(neither removed nor moved)
(20) Use to
rearrange
(19) Click to hide
selected column
Getting started
Hands-on guide >
428XL Users Manual Vol. 1 59
April 11, 2013
2
Figure 2-26
23. To resize a column, simply drag its border to the desired width.
Some columns, however, have a minimum width that you are not
allowed to override.
24. Clicking on a column heading may cause an up or down arrow to
appear in that heading, allowing you to scroll through the table if
more rows can be viewed.
(22) Drag and drop
column heading
(23) Drag border
to resize
Getting started
System status archive tool (File Packager) >
60 428XL Users Manual Vol. 1
April 11, 2013
2
System status archive tool (File Packager)
In the event of a problem with your 428XL system, you may want to
archive some log files containing information on the systems
behaviour, for example in order to send them to SERCELs customer
support centre.
To do that, you can use the Packager command
available by right-clicking on the connection icon in the
launcher bar. That archiving tool automatically finds
the files to archive, and compresses them into a single
file in ZIP format.
The File Packager uses the configuration instructions
contained in a text file, with .cfg as extension, located in the following
directory:
/export/home/user428/Sercel/e-428v./eHCI/filePackager/filePackager
In the configuration file are three sections:
baseDir: used to specify which directory to search, if a relative
search path is used;
packFile: used to specify the name of the ZIP file to create. For
example, /export/home/e-428/logPack.zip will create the
logPack.zip archive file in the /export/home/e-428 directory.
fileList: used to specify which files to find, with an absolute or
relative search path.
You may want to place the archive file on the crews Web site (or copy
it to whatever location you like). To do that:
- Open the configuration file to see which path and file name is
specified in its packFile section.
- Go to the specified directory and move or copy the zip file to the
desired location. See The crews Web site (page 61).
Figure 2-27
Getting started
The crews Web site >
428XL Users Manual Vol. 1 61
April 11, 2013
2
The crews Web site
Click on the Website icon in the launcher bar. This opens the Web
browser with the crews Website home page open in it.
Figure 2-28
Access to all menus except Help is securized. Because the Web site can
be accessed direct from any browser, an authentication box appears on
your first attempt to download or upload files, or see Identity
information.
Figure 2-29
Simply enter the same User Name and Password (which a Senior
Observer must have given to you) as you used to open your user
session.
The Identity Card menu displays information on the server machine
(identification, memory size, sercel products hosted on that machine,
patches installed, etc.).
Website
Getting started
The crews Web site >
62 428XL Users Manual Vol. 1
April 11, 2013
2
The Download menu prompts the list of files contained in the
servers /export/home/e-428/webServer/base/sercel/publication/
out directory. This may be files from the Log windows Publication
folder, or a screenshot or whatever other file the Observer may have
placed in that directory for users to download). Selecting a file (by
clicking on it) opens a dialog box asking you if you want to open the
file or save it to your computers disk.
Figure 2-30
The Upload menu allows you to select a file on your computers disk
and load it to the server. The file is loaded to the following directory:
/export/home/e-428/webServer/base/sercel/publication/in
Getting started
The crews Web site >
428XL Users Manual Vol. 1 63
April 11, 2013
2
The Server logs menu
Figure 2-31
The Packager menu
The Help menu displays help about the 428XL Graphic User
Interface (same as the Help button in the launcher bar).
Getting started
The Chat tool >
64 428XL Users Manual Vol. 1
April 11, 2013
2
The Chat tool
Click on the Chat icon in the launcher bar. This opens a window that
allows you to see who is connected to the 428XL server and send
messages to any of those users.
Figure 2-32 Chat window
Simply type your message in the text box at the foot of the window,
click in the list box to select the user you want to reach, and then click
on the button in the lower right corner to send the message. This causes
a window to pop up on the users computer with your message in it.
To select two or more users, press the Control key while clicking in the
list.
Type in your
message
Click to send
Chat
428XL Users Manual Vol. 1 65
April 11, 2013
Chapter
3 Installation setup
This chapter describes the Installation setup window. It
includes the following sections:
Overview (page 66)
Seismic recording instrumentation (page 67)
Peripherals (page 72)
Export mode (page 74)
Mobile Receiver Unit (MRU) (page 76)
428XL scalability (page 77)
Master/Slave (page 79)
Unmanned (page 81)
Installation setup
Overview >
66 428XL Users Manual Vol. 1
April 11, 2013
3
Overview
Clicking on the Install icon in the 428XL launcher bar
opens a window to be used when you install the system or
whenever you install a new software version, or another type
or vibrator electronics, or if you change the number of LCI-428 units,
etc.
After making the desired selections in the Install window, click
Apply. This reboots the server computer.
WARNING
The new settings will not take effect until the server computer has
booted up.
In addition, after adding or changing an LCI unit, the system may ask
you to reload LCI software (see 428XL Installation manual).
Installation setup
Seismic recording instrumentation >
428XL Users Manual Vol. 1 67
April 11, 2013
3
Seismic recording instrumentation
.
Figure 3-1 Install window (Main tab)
e428 Lite
Choose this option if you are installing a 428Lite box rather than an
LCI-428. See 428XL Installation Manual for hardware installation.
Unmanned
Choose the Unmanned option if the system is configured to use a UPS
and CDU to protect it from power cuts, for example for the
Microseismic operation mode.
This option is not available if the e-428 Lite option is ticked.
If the Unmanned option is ticked, then the Unmanned tab is available.
Click on this tab to set the associated parameters. See Unmanned
(page 81).
Installation setup
Seismic recording instrumentation >
68 428XL Users Manual Vol. 1
April 11, 2013
3
Instruments On Field
These buttons allow the system to customize the graphic user interface,
depending on the instrumentation to be used. The specific parameters
and/or commands attached to a type of instrument are hidden and
disabled unless and until you choose that type of instrument in this
window.
See DSU3 tilt correction (page 179).
Disk Buffer
The system uses a file repository in which it temporarily stores your
SEGD files until the Export process can accept them.
Local Disk: the file repository will use the /var/dump directory on
the local disk of the server computer.
The files can be arranged in different manners in the repository (see
Backup Settings on page 95).
LCI-428
Choose the number of LCI-428 units you want to use, and enter the
network address of each of them in the associated fields. You can
choose any address from 172.30.201.1 to 172.30.210.1. See Changing
the LCI-428 IP address (page 51) in 428XL Installation Manual.
Figure 3-2
Installation setup
Seismic recording instrumentation >
428XL Users Manual Vol. 1 69
April 11, 2013
3
Licences
These fields are used to enter the necessary passwords to enable the
software packages you wish to use. If you add or move or remove any
Ethernet interface card, then you may have to request a new licence
code from Sercel. Note that Sercel may deliver temporary licences.
Because you have to enter the e-428 licence code again whenever you
reinstall e428 software, be sure to save it (e. g. on a USB stick) and keep
it in a safe place.
Figure 3-3
e-428 licence: the e-428 Password field is used to enter the licence
code supplied to you by Sercel for your system. Record the Server
Id code prompted. You will need that Server Id (or Dongle Id code
for a laptop PC) if, for any reason, you contact Sercel to get a new
licence for your system.
When you contact Sercel to get a password for your system, you have
to provide:
- The 428XL software version.
Installation setup
Seismic recording instrumentation >
70 428XL Users Manual Vol. 1
April 11, 2013
3
- The identification code of the server computer (the Server Id
code displayed with the Server Id option button);
- The number of additional client computers you want to use,
- The number of traces;
Plotter licence: the Info... button allows you to see if any licence is
already installed.
When you contact Sercel to get a Plotter licence code for your system,
you have to provide the lmhost identification code associated with
the server after e-428 software is installed. To read that code, log in
as user428 on the server, open a Terminal window and type the
command:
lmhostid
The licence for plotters cannot be typed on the keyboard. It may be
supplied to you on a floppy disk, or CD-ROM, or USB stick or any
appropriate medium. You can also download the licence file and save
it to the server computers disk (e. g. to the /tmp directory).
To install a plotter licence:
- Insert the medium (CD-ROM, etc.) containing the licence file,
or copy the file to computers disk,
- Click on the Browse... button and select the licence file.
- Click on Install. A warning box may appear, asking you if you
wish to install a licence. If you choose to do that and a licence
already exists, you are going to overwrite that licence.
- Note: If the mention 1-jan-0 appears in the warning box, it
should not be understood as an expiry date. Instead, this means
the licence is unlimited.
- Click OK. This installs the plotter licence.
- Wait for a dialog box to appear to say if installation was
successful.
- Click Apply. This reboots the server computer.
Installation setup
Seismic recording instrumentation >
428XL Users Manual Vol. 1 71
April 11, 2013
3
Guidance licence: the Guidance Password field is used to enter the
licence code for the VE464 guidance option. When you contact
Sercel to get a Guidance licence code for your system, you have to
provide:
- The identification code displayed in the DPG Host Id field;
- The number of vibrators (DSDs) you want to steer.
- The Guidance software version.
OVC Navigation: for OVC users only, enables source navigation
functions (Ready indicator in jOperation windows Active Source
view, fleet position in jPositioning).
Installation setup
Peripherals >
72 428XL Users Manual Vol. 1
April 11, 2013
3
Peripherals
Figure 3-4
Nb of DPG modules
For VE432 users only: this field is used to specify how many (up to 4)
vibrator controller modules (DPGs) are attached to the system. (For
example, each vibrator fleet you want to use in slip-sweep mode has its
own vibrator controller).
Vibrator type
Choose the type of vibrator electronics you want to use for vibroseismic
sources if any. The following options are available:
VE464 (SERCEL).
VE432 (SERCEL).
OVC: for GEOSVIP, PELTON (VIBPRO) or Force One vibrator
electronics.
Other: for any other type of vibrator electronics.
See the wiring of the Blaster connector in 428XL Installation Manual.
Blaster type
Choose the type of blaster used for impulsive sources if any:
SHOT PRO (PELTON)
BoomBox
Installation setup
Peripherals >
428XL Users Manual Vol. 1 73
April 11, 2013
3
MACHA
AWD (Accelerated Weight Drop).
SGDS
SGD-S Shooter-Driven (able to supply the shooter position).
OTHER (any type). With this option, the data from the shooting
system is not processed.
Note If you select the Connected with LSI option:
- the indicator LED on FDUs, otherwise used as a test result
indicator, is used to tell the shooter whether he is allowed to
connect/disconnect an LSI between two links.
- you cannot launch a new shot until retrieval of the previous one
is complete, whatever the field equipment and the shooting
method used.
See the wiring of the Blaster connector in 428XL Installation Manual
and Source Controllers in Users Manual Vol. 3.
Number of plotters
Choose the appropriate option (1 or 2) depending on the number of
plotters attached to the system.
Plotter type
Choose the appropriate option (12 inch or 24 inch plotter).
Enter a name for each plotter in the associated Name field. The name
will appear in the Plotter main window to identify each plotter.
MAC address: (Media Access Control address). This field is used to
enter the hardware address of the plotter card, in the case of a plotter
with an Ethernet port.
Installation setup
Export mode >
74 428XL Users Manual Vol. 1
April 11, 2013
3
Export mode
You can record your SEGD files to cartridges and/or export them to
remote disks attached to the local network.
Figure 3-5
Max number of SCSI drives
This option is used for traditional recording to one or up to four
cartridge drives. Use this button to specify how many cartridge drives
may be connected.
Max number of FTP servers
If you wish to export records to an FTP server, use this button to specify
how many FTP servers may be attached to the local network.
Max number of NFS servers
This option allows SEGD files to be exported in real time to one or more
disks simultaneously. Use this button to specify how many (up to 20)
NFS servers may be attached to the file hierarchy, and use the Type of
NFS Server button to choose the type of system:
NAS4000: (TCP protocol) choose this option if you are using the
NAS4000 system (featuring removable disks) from Sercel.
Other: (UDP) choose this option if you are using the early-design
(Intellique) NAS from Sercel (NAS800, NAS2000, etc.), or a NAS
system other than from Sercel.
Note that if the Unmanned option is selected in the Main tab, then the
maximum number of NFS servers is limited to 2.
Installation setup
Export mode >
428XL Users Manual Vol. 1 75
April 11, 2013
3
To attach a remote disk to the local network, see Peripherals in 428XL
Installation Manual.
Figure 3-6
To install a NAS disk or a file server, see 428XL Installation Manual.
172.27.128.2
(172.27.128.x.)
172.27.128.1
GUI
172.27.128.41
FileZilla
172.27.128.99
Local network
Observer
FTP user
NFS
server
428XL server
Installation setup
Mobile Receiver Unit (MRU) >
76 428XL Users Manual Vol. 1
April 11, 2013
3
Mobile Receiver Unit (MRU)
Figure 3-7
If a tracking box is connected to the computer (i.e. if you wish to
implement the vehicle tracking function), activate the Use MRU
button. As a result you have to do the following:
From the GPS Port 1 button, select the serial port to use for the
vehicle tracking function. The Base Port button allows you to
choose a second serial port to be used for service messages from the
tracking box.
From the Driver Type button, select the protocol used by the
tracking box.
Enter the password for the vehicle tracking function into the
Licence field (or else communications with the tracking box will
not be allowed).
Installation setup
428XL scalability >
428XL Users Manual Vol. 1 77
April 11, 2013
3
428XL scalability
Your systems capabilities depend on its resources (for example the
server computers RAM size) and on how many traces you want to
record, on the operating mode, on the sample rate, etc. The 428XL
Scalability tab allows you to change some default settings in order to
best suit your crews requirements.
Figure 3-8 Scaling parameters
Maximum nb of traces: (4000 by default) Maximum number of
retrieved traces; depends on the server computers RAM size.
Maximum open VP: (2 by default, 4 max.). Up to four Vibroseismic
sources can be used alternately (Flip-Flop mode). If you choose the
Work by Acq (page 293) option, the system can start shooting a Source
Point with multiple acquisitions to stack, but suspend it and let the
focus jump to another source and Source Point. In that case, use this
field to tell the system how many (up to 4) Source Points it can leave
suspended.
RAM size 428-Lite (4 GB) Less than 8 GB More than 8 GB
Max. number of
traces
1000 4000 10000
Installation setup
428XL scalability >
78 428XL Users Manual Vol. 1
April 11, 2013
3
Maximum simult VP: (1 by default). This field is used to tell the
system how many Vibroseismic sources you want to use
simultaneously. The allowable number (up to 4) depends on the
server computers RAM size.
Note: 428XL software version 2.0 does not allow the use of
simultaneous sources.
Maximum nb of samples: (12001 by default). The maximum
allowable number of samples depends on the other three parameters.
It is determined by the system as you click on the Compute Samples
button. This allows you to determine the allowable record length (by
multiplying it by the sample rate you want to use).
RAM size 428-Lite (4 GB) Less than 8 GB More than 8 GB
Max. number of
simultaneous VPs
1 2 4
Installation setup
Master/Slave >
428XL Users Manual Vol. 1 79
April 11, 2013
3
Master/Slave
Unless you want to use a Master/Slave configuration, choose the
Standalone (default) option.
Figure 3-9
The Master/Slave mode allows using up to four separate 428XL
systems synchronized to a Master 428XL, if an Ethernet bridge is
provided for the Master and Slave to communicate with each other.
The different 428XL servers should be set up as follows:
On the 428XL server to be used as Master, choose the Master
option and tick the associated buttons, depending on which Slave
systems you want to use (Slave 1 Used, Slave 2 Used, etc.). As a
result, a Master Enable / Master Disable button will be available in
the jOperation window of the a Master system.
On each Slave 428XL system, choose one of the four available
Slave server address options you must choose a different IP
address on each Slave system. This will change the last figure in its
IP address to 2 (or 3, 4, 5) so that is can communicate with the
Installation setup
Master/Slave >
80 428XL Users Manual Vol. 1
April 11, 2013
3
Master server. As a result, a Slave Enable / Slave Disable button
will be available in the jOperation window of each Slave system.
See Master/Slave operation (page 384) for details.
Installation setup
Unmanned >
428XL Users Manual Vol. 1 81
April 11, 2013
3
Unmanned
The Unmanned tab is only available if the Unmanned option is
selected in the Main tab.
Use this option if the system is configured to use a UPS and CDU to
protect it from power cuts, for example for the Microseismic operation
mode: the system will periodically check whether SEG-D files keep
being generated and will automatically reboot the server and LCI in the
event of an interruption.
The Unmanned tab has the following parameters:
Figure 3-10
To set the recurrence rate of the check for new SEG-D files, enter the
desired time in the SEGD files checked every field.
In Microseismic mode, a Line Error Recovery option is available
that causes the system to automatically go to Field Off, then Field
On in order to reset the field electronics if an error arises.
- The Number of field off / field on sequences parameter allows
you to specify how many (1 to 10) Field Off/On operations are
allowed in order to recover the line in the event of line errors.
- The Line recovery timeout is used to specify the time (60 to
36000 s) between two successive Field Off/On operations.
Note that the maximum allowable time to recover the line
(Number of field off / field on sequences Line recovery timeout)
must be less than or equal to the time specified in the SEGD files
Installation setup
Unmanned >
82 428XL Users Manual Vol. 1
April 11, 2013
3
checked every field, or else a warning will pop up (in that case, you
must increase the value in the SEGD files checked every field, or
change the other two parameters).
The status bar in the jOperation window indicates if the Unmanned
mode is off or on.
Figure 3-11
428XL Users Manual Vol. 1 83
April 11, 2013
Chapter
4 Configuration
This chapter includes the following sections:
The main window (page 84)
The Setup menu (page 88)
On Line/Off Line (page 100)
Configuration
The main window > Overview
84 428XL Users Manual Vol. 1
April 11, 2013
4
The main window
In this section:
Overview (page 84)
Customer Support (page 85)
Copyrights (page 85)
Identity Card (page 86)
Overview
The jConfig window serves two main purposes:
Firstly, it is used to set up some basic parameters at the beginning of
a survey, for instance the sample rate.
Secondly, it is used to control and initiate communications with the
Line Controller Interface each time the system is switched on.
An additional task is to report on the current hardware and software
configuration of the system, via the Identity Card.
Figure 4-1
Note You can shrink/expand the window by clicking in the Activity
area.
Click to shrink
or expand
Configuration
The main window > Customer Support
428XL Users Manual Vol. 1 85
April 11, 2013
4
Customer Support
Please note SERCEL Customer Support Hot Line with our dedicated
phone number:
- Outside FRANCE +33 2 40 30 58 88
- In FRANCE 02 40 30 58 88
This allows you to get in touch with our SERCEL Customer Support
Department, at any time and seven days a week, to ask any question
related to the use of your SERCEL equipment.
One of our experienced, english speaking Customer Support Engineers
will make every effort to give you any technical support you need.
The Hot Line includes a vocal mail box for calls outside normal
business hours: just leave a spoken message and we will get back to you
first thing in the morning (including Saturdays and Sundays).
SERCEL is committed to offering you our closest support for the
success of your field operations.
Copyrights
Clicking on this button in the 428XL main window opens a box
providing information on how to call the Customer Support
Department for help.
Clicking on this button displays the list of copyrighted
software and libraries used in your 428XL Graphic User
Interface.
Configuration
The main window > Identity Card
86 428XL Users Manual Vol. 1
April 11, 2013
4
Figure 4-2
Identity Card
Figure 4-3
Clicking on this button displays a description of the configuration
of your system (Software version, software patches installed,
passwords, computer configuration, plotter type, hardware
configuration of 428XL Line Controller Interface, etc.).
Configuration
The main window > Identity Card
428XL Users Manual Vol. 1 87
April 11, 2013
4
Of particular note is the following information:
- Host I.D.
- Software Version.
- Passwords (and LCI board numbers).
- Maximum number of client user sessions allowed.
- Module Type (428).
The Customer Support Department will solve your problem more
quickly if you provide them with a detailed description of the
configuration of your system, using the Identity Card command.
Configuration
The Setup menu > Crew setup window
88 428XL Users Manual Vol. 1
April 11, 2013
4
The Setup menu
In this section:
Crew setup window (page 88)
User Info setup (page 92)
SEGD setup (page 92)
Disk Record setup (page 95)
Swath setup (page 97)
Crew setup window
Note You are not allowed to change these parameters unless and until
the line is turned off.
Figure 4-4
Crew Name
(16 characters). The Crew Name you enter in this field is used along
with the Device Name created by the Export window to record the
Recording Entity Name field in the Tape Label block for Revision 2.1-
compliant SEGD files.
Configuration
The Setup menu > Crew setup window
428XL Users Manual Vol. 1 89
April 11, 2013
4
Sample rate
(1/4, 1/2, 1, 2 or 4 ms)
This option button allows you to specify the sampling interval to be
used on all traces.
Filter Type
(8N_Lin, 8N_Min).
Each 428XL channel has a built-in Digital Signal Processor that
performs high-cut filtering, depending on the option selected in this
setup window.
N stands for the Nyquist Frequency, i.e. half the sampling frequency.
The available filters have a -3 dB point at 0.8 times the Nyquist
Frequency, i.e. 0.4 times the sampling frequency:
- 100 Hz @ 4-ms.
- 200 Hz @ 2-ms.
- 400 Hz @ 1-ms.
- 800 Hz @ 0.5-ms.
- 1600 Hz @ 0.25-ms.
They feature a slope of about 370 dB/octave. The pulse response
ringing, however, decays slowly.
The attenuation is at least 120 dB for all frequencies above the Nyquist
Frequency, preventing any aliasing effect.
The 428XL allows the user to choose between:
- linear-phase type or
- minimum-phase type.
The amplitude spectrum does not depend much on the type of filter
(linear or minimum phase), unlike the phase spectrum.
Configuration
The Setup menu > Crew setup window
90 428XL Users Manual Vol. 1
April 11, 2013
4
Linear Phase
This type of filter is ideal as far as phase considerations are concerned,
as all the frequencies are delayed by the same amount. That delay is set
to zero in the 428XL.
In return, this kind of filter has a pulse response with leading ringing
(precursors) as well as lagging ringing (actually, the pulse response is
symmetrical with respect to time 0).
Minimum Phase
The minimum phase type is causal, i.e. its pulse response, much like
analog filters, starts at time 0, peaks and then rings (no ringing prior to
the peak).
The delay, however, somewhat depends on the input frequency.
Default Line Data Rate
(8 or 16 Mbits/s) This option button sets the default data rate for all
acquisition lines. To determine which option to choose, you need to
know which type of field electronics is used.
- The FDU-428 field electronics supports both 8 and 16Mbits/s
data rates. (Note that the DSU3GPS-428 only supports 16 Mb/s).
- The FDU408 field electronics supports only the 8Mbits/s
option.
WARNING
If any FDU408 electronics is deployed and you choose 16Mbits/s, it
will not be seen by the system unless you use the The Form Line setup
(page 226) to change the data rate to 8 Mbits/s on those line segments.
Time Management
This option button allows you to choose which clock to use to determine
the time of shots:
Internal Clock: shot time is synchronized on the server computers
clock. This option does not allow Slip-Sweep (page 284) operations.
Configuration
The Setup menu > Crew setup window
428XL Users Manual Vol. 1 91
April 11, 2013
4
Source Controller: shot time is synchronized on the source
controller (e. g. for explosive operations) connected to one of the
Blaster connectors on the LCI or 428-Lite box. You have to select the
appropriate Blaster connector from the From Source Controller
Connection option button.
GPS: shot time is synchronized on the GPS time from a GPS receiver
attached to the LCI or 428-Lite box. From the GPS Type option
button, select which type of GPS receiver is used. The GPS time of
the acquisition TB is recorded in the Extended Header (bytes 877-
883). If you want to use DSU3GPS-428 links, select the Novatel
Propak GPS type (which allows locking the clock of the LCI-428 to
the OCXO oscillator from the GPS receiver).
Figure 4-5
Post Annotation Logging
If the actual source COG is not available at the moment the SEGD file
is generated, this option determines whether or not the system is
allowed to update this field when the data is available at a later date, that
is after all status messages have been received from all vibrators
(VE464 or VE432 DSDs). If auxiliary traces are used to record vibrator
motion signals, this option enables the position of each vibrator to be
recorded in the Trace Header of those auxiliary traces. See SQC Dump
mode (page 348) or SQC Dump mode with VE432 (page 361).
Configuration
The Setup menu > User Info setup
92 428XL Users Manual Vol. 1
April 11, 2013
4
User Info setup
An External Header appears in every SEGD file generated by the
system. Selecting User Info from the Setup menu opens a window
that allows you to enter any extra information not supported by the
standard header (ASCII characters) that you wish to be recorded in the
External Header. It can be left blank if not required.
Figure 4-6
The size allocated to the External Header depends on which options you
choose in the SEGD setup menu.
SEGD setup
If you choose the Advanced rather than Standard option, you can
choose between the following SEGD format options:
Figure 4-7
Configuration
The Setup menu > SEGD setup
428XL Users Manual Vol. 1 93
April 11, 2013
4
SEGD Level
Depending on which option you choose with this button, the system will
generate records complying with SEGD standard Rev. 1.0 or Rev. 2.1.
Revision 2.1 supports the latest industry techniques and practices,
especially the use of very-high-capacity recording media, and causes a
label (a 128-byte block) to be written at the beginning of each tape or
storage unit. The term storage unit is used indifferently for a
traditional tape or a tape-like volume of data on any recording
medium.
This option determines the format Revision of not only the SEGD files
but also of the SPS files the system generates. However, this is of no
effect on the SPS files you import: the system automatically interprets
imported SPS files in either format, regardless of the SEGD revision
option selected. See The SPS format (page 581).
Number of Record Channel Sets
You can choose between the following options for the number of
channel sets per record: 16 (Standard), 32 or 64.
External Header Size
You can choose between the following options for the maximum length
(kByte) of the External Header in the SEGD file: 1 or 64 (standard);
1to28 in 4-kByte steps (Advanced).
The following information is appended in the External Header header:
- Information from the shooting or navigation system,
- User information from the Config client windows setup,
- Source comment from Operation client window.
API Producer code
Used (for SEGD Rev. 2.1 files) to specify the organization code of the
storage unit producer, to be recorded in the Tape Label block.
Organization codes are assigned by POSC, which maintains the current
Configuration
The Setup menu > SEGD setup
94 428XL Users Manual Vol. 1
April 11, 2013
4
list of codes. See info@posc.org or Organization Codes (page 171) in
428XL Users Manual Vol. 2.
Serial Number
(8 characters) This field is used along with the Current Tape Nb
(page 466) parameter to generate the Serial Number field (an ID used
to distinguish the storage unit from other storage units in your archive)
to be recorded in the Storage Unit Label (for SEGD Rev. 2.1 files).
Use External Tape Labels
You can choose this option if you want to enter a name (physical label)
for each tape. Unlike the tape number which is automatically assigned
by the system, External Tape Labels must be entered manually. If you
choose this option, then the system will ask you to enter a tape label
each time you load a tape on a tape drive. See the Export windows Tape
setup: External Label (only for SEGD Rev. 2.1 files) on page 466.
Configuration
The Setup menu > Disk Record setup
428XL Users Manual Vol. 1 95
April 11, 2013
4
Disk Record setup
The system uses a file repository in which it temporarily stores your
SEGD files until the Export process can accept them (see Disk Buffer on
page 68). The Disk Record setup window lets you choose the way the
system will arrange the files in the SEGD repository.
Figure 4-8
Disk record mode
The Standard mode will save your production files to
/var/dump/normal and your test files to /var/dump/test.
The Advanced mode may create subdirectories, depending on
which Backup Settings option you select.
Backup Settings
The files can be arranged in three different manners:
Flat: all files are saved to the same directory (/var/dump). Note that
if you are recording multiple swaths to tapes, you are likely to have
data from different swaths being recorded to the same tape, as the
Export process will not allow you to sort the data by swath.
Configuration
The Setup menu > Disk Record setup
96 428XL Users Manual Vol. 1
April 11, 2013
4
WARNING
If you choose Flat and you are recording multiple swaths to tapes, be
sure the offset of the initial file number for each swath is large enough
in the Swath setup (page 97).
Swath Name: the swath name (<swathname>) of each swath is used
to create a distinct subdirectory for each swath. Production files are
recorded to /var/dump/<swathname>/, e. g. /var/dump/swath1,
/var/dump/swath2, etc. Test files are recorded to /var/dump/test.
Use this option if you want to record to a tape and prevent different
swaths from being recorded on the same tape and therefore mixed.
Naturally, you will not be able to export multiple swaths
concurrently: in the Export window, you will select one /var/dump/
<swathname>/ directory to export it to tapes, then select another
swath directory and export it to new tapes, etc.
The Tape Set parameter in the Swath setup (page 97) allows
concurrently exporting multiple swaths to distinct directories on NFS
disks.
Swath Name and Julian Day: same as with the Swath name
option, but for each swath, a subdirectory is created for each julian
day. Production files are recorded to
/var/dump/<swathname>/<julianday>/,
e. g. /var/dump/swath1/jdayXXX, /var/dump/swath2/jdayXXX,
etc. Test files are recorded to /var/dump/test.
Configuration
The Setup menu > Swath setup
428XL Users Manual Vol. 1 97
April 11, 2013
4
Swath setup
You may have multiple sets of lines to shoot, each set being referred to
as a swath. This setup window allows you to create a Swath Type for
each set of lines to shoot.
To make changes to any row in the list box, double-click on it, fill in the
fields above the list, then click Add or Change or Delete, as required.
To save and enable your changes, click Apply. (To revert to the former
settings, click Reset instead). You cannot use Apply if Field On is
selected in the Line window.
Figure 4-9
Note that deleting a swath (by clicking Delete) deletes all the objects
(receiver points, source points, etc.) and setups relating to that swath in
the Line, Operation and Positioning windows, but this does not delete
the results in the Log window. You cannot use Delete if Field On is
selected in the Line or Positioning window.
Swath Number
Identification number to be assigned to the set of seismic lines to shoot,
described in The Source Point Setup (page 275) in the Operation
window. Typically, that is the set of receiver positions and source points
depicted in a set of SPS R-, S- and X-files you import via the Log
window. If you want to shoot two or more swaths, create a Swath
Number number for each swath, set it to Active, and see Multiswath
(page 310).
swath1
swath2
swath2
Configuration
The Setup menu > Swath setup
98 428XL Users Manual Vol. 1
April 11, 2013
4
Swath Name
Used to enter a user-friendly name for this swath.
File Nb
Identification number of the first seismic record SEGD file for this
swath. After the initial number is specified, the system automatically
increments the file number on each seismic record.
WARNING
The File number&Swath number pair is used as an identification key
for updating log files. Therefore, reusing any File number&Swath
numberpair will erase the shot information previously recorded in log
files with the same identification key.
WARNING
If you are recording multiple swaths to the same directory (using the
same Tape Set with the Flat option in the Disk Record setup on
page 95), enter a different initial File Number with a large enough offset
for each swath.
Tape Set
The Tape Setup menu (page 465) in the Export window allows you to
create a distinct Tape Set (set of tape numbers) for each swath, so that
multiple swaths can be exported concurrently to distinct directories on
NFS disks. The Tape Set is only intended for exporting to NFS disks,
not tapes.
Use the Tape Set field in the Swath setup to select which Tape Set to
associate with which swath. As a result, a distinct set of tape numbers
will be used to record each swath when your SEGD files are exported
to NAS disks.
You are, however, allowed to use the same Tape Set for different swaths.
Configuration
The Setup menu > Swath setup
428XL Users Manual Vol. 1 99
April 11, 2013
4
You also have to select a Tape Set for test-type SEGD records. Test
records can use the same Tape Set as production records.
Active
Choosing Active from this option button causes a selection tab to be
created for this Swath Number number in the Line windows Survey
and Spread setups, and in the Operation window. Also, this swath
number will be available in the Log window so that you can select it
when loading an SPS-X file to generate The Source Point Setup
(page 275) in the Operation window (since the SPS-X format does not
make provision for a Swath identification parameter). You can set
multiple swaths to Active. See Multiswath (page 310).
Comment
Used to enter any comment you like (for example a self-explanatory
description of the swath).
Test File Nb
Identification number of the first test-type SEGD file. After the initial
number is specified, the system automatically increments the file
number on each test record. Use the associated Tape Set dropdown list
button to select a set of tape numbers for test-type SEGD records.
Configuration
On Line/Off Line >
100 428XL Users Manual Vol. 1
April 11, 2013
4
On Line/Off Line
Clicking Off Line inhibits data acquisition and recording, and enables
local functions on the Graphic User Interface. You are then allowed to
make any changes to parameter settings in the Setup menu in each
main window.
Clicking On Line enables data acquisition and recording. This also
automatically performs a Look function, as well as an instrument test on
the auxiliary traces.
Figure 4-10
The Activity box shows the progress of the data flow, in the form of
traffic lights for each stage in the 428XL. When the process stage is idle,
all three lights are off. Otherwise, the colours should be interpreted as
follows:
The green light means the data stream is being processed or dumped
to the next process stage.
The orange light comes On if the processor is unable to dump the
data presently being processed to the next stage, for example because
Manual instead of Auto is activated in the Export or DPG
main window.
The red light comes On if the processor is unable to process the
incoming data, or unable to dump the processed data to the next stage
(therefore unable to accept any more data).
Acquisition length downcount or delay downcount
Current file number
Number of shots being processed
Number of shots to retrieve
File being exported
Configuration
On Line/Off Line >
428XL Users Manual Vol. 1 101
April 11, 2013
4
The following indicators may appear:
ACQ (Acquisition progress). At the foot of the ACQ light is a time
counter, preset to the acquisition length value (including any
programmed delay) at the start of each acquisition, that indicates the
time still to elapse before the present acquisition (or delay) is
complete.
- The green light means that acquisition is in progress.
- The orange light comes On during the programmed delay, if
any, between acquisitions, or if seismonitor in the Line main
window is running.
- The red light means no acquisition can be performed at the
present time (e. g. because there are too many shots to retrieve).
RTV (Retrieving). The counter at the foot indicates the number of
shots still to be retrieved (max. 2).
- The green light means that the seismic data collected from the
FDUs, and stored in the LAUs, is being retrieved by the retrieval
process (PRM).
- The orange light means that acquisition is complete but it is not
entirely retrieved.
- The red light means retrieval is no longer possible.
PROC (Processing). The counter at the foot indicates the number of
shots being processed.
- The green light means data is being transferred from the
retrieval process (PRM) to the processing queue, and/or Noise
Elimination and/or Correlation is in progress.
- The orange light means the processing is no longer performed
in real time.
- The red light means no processing can be performed at the
present time.
Configuration
On Line/Off Line >
102 428XL Users Manual Vol. 1
April 11, 2013
4
REC (Recording to SEGD repository disk). This indicator is
associated with the file repository in which the system temporarily
stores your SEGD files until the Export process can accept them. It is
red until the first file is recorded. Then it should go off and only turn
green when a file is being recorded to the SEGD repository. This
indicator going orange or red would mean that disk space is running
out. The number of the file being recorded to the SEGD repository
appears at the foot of the indicator.
EXPORT (Exporting). The number of the file being exported
appears at the foot of the indicator.
- The green light means that a file is being copied from the SEGD
repository to the export target device.
- The orange light comes on if the processor is unable to write to
the export target device, for example if the system is waiting for
a tape device to be ready or a disk to be mounted.
- The red light comes on if the processor is unable to accept any
more data because Manual instead of Auto is activated. No
file is being exported.
DPG (if a VE464 or VE432 DPG vibrator controller is installed).
- The green light means that a sweep is in progress.
- The orange light means that no sweep is being taken but the
DPG window is ready.
- The red light means that only local functions are enabled in the
DPG window (theManual mode is selected).
428XL Users Manual Vol. 1 103
April 11, 2013
Chapter
5 Line
This chapter includes the following sections:
The main window (page 104)
Topographic views (page 107)
Numeric views (page 123)
Histogram view (page 125)
The Survey setup (page 127)
The Layout setup (page 134)
The Spread Type setup (page 145)
The Look setup (page 151)
LAU Leakage setup (page 153)
Advanced layouts (page 155)
Working with DSU3-428 & DSUGPS links (page 162)
Working with ULS field equipment (page 180)
Radio telemetry (page 198)
Test functions (page 215)
The Form Line setup (page 226)
The Synthetic setup (page 231)
The Download setup (page 237)
Line
The main window >
104 428XL Users Manual Vol. 1
April 11, 2013
5
The main window
The Line client window provides access to all of the test and utility
functions necessary for management of seismic lines and spreads.
The main window gives a graphical or numeric representation of all
field equipment connected to the Line Controller Interface, together
with Sensor and Instrument test results. Selective colour coding is used
to highlight problems that may affect data quality.
Figure 5-1
The View menu allows you to customize the main window by choosing
one or more views to display. Then you can resize your display panes
by dragging the desired border.
For details on how you can arrange the views and toolbars as you would
like them, see the Hands-on guide (page 52).
Line and spread parameters are programmed through the Setup menu.
See The Survey setup (page 127) to describe the survey, and The Layout
setup (page 134) to generate markers.
Line
The main window >
428XL Users Manual Vol. 1 105
April 11, 2013
5
When you open the Line window, only the recording unit and the
LAUX-428s attached to it are visible in the default (Field Off) view.
When you go to Field On, all the field electronics connected becomes
alive and can be viewed in the main window. In topographic views, the
amount of graphic details depends on the zoom factor. If you zoom in,
the ends of each FDU or DSU Link are visible (the system uses the Link
properties recorded in each FDU or DSU). The number of channels in a
Link is user-customizable.
FDU/DSU channels can be in one of three states: acquisition
(seismonitor or recording), field update (the database is continually
updated with test results), or idle (no operation in field electronics).
You enable the field update mode in The Look setup (page 151), by
choosing the Auto Look option and selecting the tests you want to do
(Sensor Resistance, Tilt, Leakage). If you do that, all channels go to the
field update mode (unless no markers are defined) as soon as you go
to Field On. As a result, the selected tests are performed in real time
and can be viewed.
Whenever a new field unit is laid out, it does not appear in the
topographic view until the spread is formed again. If the spread remains
the same for consecutive shots (VPs) in continuous mode, no spread
forming is performed, so any new unit laid out will not be visible unless
you program an Auto Look between VPs in the Operation main
windows Look option (page 287) setup. If any Sensor tests are selected,
they are performed too (but if the Resistance value exceeds the specified
limit, e. g. if nothing is connected on the channel input, Tilt and Leakage
tests are not performed, even if they are selected in the Look setup).
Note: simply setting a Delay between two shots or VPs will also
cause a Look to be executed.
While active channels are collecting the data during acquisition, all
passive ones are still in field update mode if Auto Look is selected
in the Operation windows Look option (page 287) setup, and their states
are continually updated on the display if they are in lines that are not
involved in the acquisition. You can see right away if any extra units
Line
The main window >
106 428XL Users Manual Vol. 1
April 11, 2013
5
have been connected to those lines, or if any sensors or cables (called
paths) are at fault. Any faulty elements, including cables, are displayed
in red.
In case of a disruption along a Line, the Auto Look automatically
rewakes the spread and reroutes the data if necessary. In contrast, a
disruption along the Transverse is not recovered the same way: the Auto
Look will not reform the crashed spread and reroute the data (instead, a
Field Off/Field On is required).
Double-clicking on any error message in the status pane causes the
focus to jump to the unit involved in all other views.
Double-clicking on a unit in a graphic view, or its row in a numeric
view, causes the focus to jump to that unit in all other views.
Line
Topographic views > About topographic views
428XL Users Manual Vol. 1 107
April 11, 2013
5
Topographic views
In this section:
About topographic views (page 107)
Sensor view (page 111)
Instrument view (page 113)
Battery view (page 115)
Seismonitor (page 116)
Working with graphic views (page 117)
About topographic views
Topographic views provide geographic displays of the results available
from field updates.
Use the View menu or toolbar buttons to choose the type of information
to display:
Figure 5-2
Information on the survey (Sensor topo view).
Information on field units (Instrument and Battery topo views).
Sensor noise level (Seismonitor topo view).
Whatever the type of information displayed, the other results are just
one click away.
Line
Topographic views > About topographic views
108 428XL Users Manual Vol. 1
April 11, 2013
5
Figure 5-3 Topographic views
(1) The left-hand pane displays the whole survey. See Zooming
(page 118).
(2) Click on these buttons to expand or collapse the left-hand pane.
Drag the vertical border to resize the two panes.
(3) The right-hand pane displays a magnified view of the area
encompassed in the red frame selected in the left-hand pane. See
Zooming (page 118).
(4) The legend shows the programmed limits for
QC results. With the mouse pointer resting
on any element in the graphic view (Sensors/Seismonitor/
Instrument/Batteries) a tip box appears that shows the
identification of the element and its QC result if any is available,
depending on the choice made with the test option button. The
relevant legend automatically appears as the tip box shows up.
In the graphic view, the tested elements are green if within the
limits, red or blue otherwise. The limits for the sensor tests are
(1) (4) (5)
(6) (8)
(3) (2)
(7) (9)
Line
Topographic views > About topographic views
428XL Users Manual Vol. 1 109
April 11, 2013
5
adjustable through the Survey Setup menu (using the Apply
Sensors button).
(5) Field On/Field Off button. Use this button
to turn on/off the power supply to the lines.
After you go to Field On, the field equipment connected to the
LCI is visible in the Instrument view (if it is supplied with
power and loaded with the appropriate software version).
(6) Location of the mouse pointer within the graphic pane.
(7) Zoom out button: restores the previous zoom factor.
(8) Reset button: removes zooming.
(9) Status pane: displays status and error messages.
Double-clicking on any error message in the status pane
causes the focus to jump to the unit involved, in all views.
The Preferences setup allows you to choose different view options for
Lines numbers and Receiver positions.
Figure 5-4 Preferences setup
The View Axes option shows or hides the line and stake numbers.
Lines can be displayed in Ascending or Descending Line Number
order or as described in the Survey (page 128) setup.
You can choose not to show survey gaps, if any, by ticking the Collapse
Survey Gap option, in order to save space in graphic views. This only
applies to gaps that are common to all lines.
Line
Topographic views > About topographic views
110 428XL Users Manual Vol. 1
April 11, 2013
5
Figure 5-5 Collapsing survey gaps
The Background color tab allows you to change the background colour
of graphic views.
Figure 5-6
Line
Topographic views > Sensor view
428XL Users Manual Vol. 1 111
April 11, 2013
5
Sensor view
This view shows the topographic stakes and the types of sensors in the
survey.
Figure 5-7 Sensor topographic view
(1) Use this button to show or hide the sensor type in the
graphic view. (The selected sensor type number appears
inside the icon).
(2) Use the Sensor QC Type button to select the
type of sensor whose test results you want to
display.
(3) This button looks for the units connected and launches
the Sensor tests selected in the The Look setup
(page 151). See also Sensor tests (page 221).
(4) This option button is used to choose which
type of sensor QC test to launch (with the Go
button) and display.
(5) The Go button provides a shortcut for the test functions
available from the Test Setup menu. (See also Test
(4) (3) (5) (2) (1)
Line
Topographic views > Sensor view
112 428XL Users Manual Vol. 1
April 11, 2013
5
functions on page 215). It launches the selected QC test on the
selected units. (If no units are selected, then the test is performed
on the whole survey). This clears the test results, and the units
are shown in blue until the test is completed and new results are
available.
To select a set of units in the graphic view, see To select one or more
elements (page 117). After you launch a test function on any unit, a grey
background appears on that unit in the graphic view, meaning that the
unit is busy.
The colour of each sensor icon depends on the limits programmed for
the Sensor test selected using the option button (Resistance, Tilt, Noise,
Leakage). To change the Sensor test limits, see Sensor type (page 131)
in the description of The Survey setup.
Sensor icons in the graphic view are shown in:
Green if within the Sensor test limits.
Red if out of Sensor test limits.
Light blue if not tested.
Any mute sensor appears as a blue cross (no sensor is detected).
Line
Topographic views > Instrument view
428XL Users Manual Vol. 1 113
April 11, 2013
5
Instrument view
This view shows all the field equipment connected in the survey.
Figure 5-8 Instrument topographic view
(1) This button looks for the units connected.
(2) This option button is used to choose which
type (Distortion, CMRR, Gain error, Phase
error, Noise, Crosstalk) of instrument QC test to launch (with the
Go button) and display. You do not need to click on Go to get
the results from self-tests (Auto Test option).
(3) The Go button provides a shortcut for the instrument
test functions available from the Test Setup menu. See
also Test functions (page 215). It launches the selected QC test on
the selected units. (If no units are selected, then the test is
performed on the whole survey). This clears the test results, and
the units are shown in blue until the test is completed and new
results are available.
(1) (2) (3)
FDU
Line
Topographic views > Instrument view
114 428XL Users Manual Vol. 1
April 11, 2013
5
To select a set of units in the graphic view, see To select one or more
elements (page 117). After you launch a test function on any unit, a grey
background appears on that unit in the graphic view, meaning that the
unit is busy.
The buttons in the upper-left corner allow you to highlight or dim some
of the elements for better legibility.
Figure 5-9
For an LCI-G, the icon is slightly different.
Figure 5-10
Right-clicking on any of these buttons brings up a popup menu that
allows you, for example, to get traceability information for the whole
selection.
By default, the Instrument graphic view displays the results from self-
tests. The colour code is as follows:
Green: The unit is identified and its self-test is correct.
Orange: The unit is identified but no self-test has been performed
(because of a transmission problem).
Red: The unit cannot be used, or its self-test failed. See
Numeric views (page 123) for details.
Grey: There is no Marker on the line segment.
Figure 5-11 LAUX-G with attached GPS receiver (sync OK)
Stakes
LAUX FDU Cable path 428XL
LSI
LCI-428 LCI-G
LAUX-G
(GPS receiver sync OK)
Line
Topographic views > Battery view
428XL Users Manual Vol. 1 115
April 11, 2013
5
After connecting a GPS receiver to an LAUX-G and going to Field On,
a red LAUX-G icon is displayed, and the associated tip box reads GPS
synchronization in progress, until GPS synchronisation is complete.
Figure 5-12 LAUX-G with attached GPS receiver (sync in progress)
Figure 5-13 LAUX-G with attached GPS receiver (sync failed)
Battery view
This view shows the battery-operated units deployed.
Figure 5-14 Battery topographic view
With the mouse pointer resting on any battery-operated unit, a tip box
appears, showing the type of the unit, its serial number and its power
supply voltage. The legend at the top of the window shows the
programmed limit for the battery voltage, which is adjustable using the
Threshold slider button.
The icons in the Battery view are shown in green if the battery voltage
is above that threshold, red otherwise.
LAUX-G
(GPS receiver not synchronized)
Legend
Tip
Threshod adjust
Line
Topographic views > Seismonitor
116 428XL Users Manual Vol. 1
April 11, 2013
5
Seismonitor
The Seismonitor topographic view allows you to view the sensors in
terms of input signal rather than sensor type.
It shows the active spread:
Active sensors appear as green squares,
Dead sensors appear as red squares,
Mute sensors appear as dark blue squares,
Stakes defined with no sensors appear as yellow crosses.
When the Seismonitor pushbutton is activated, this view also allows
real-time noise monitoring: the level on each receiver is represented
using eight 6-dB steps for both the height and colour (from green to red)
of each receiver icon, depending on the gain selected for Seismonitor.
The red colour step corresponds to the highest step in the level scale.
Figure 5-15
The seismonitor gain is applied to both seismic and auxiliary traces.
The Gain slider button, in conjunction with the Sensor Type option
button, allows you to adjust the Seismonitor gain for each type of
sensor.
Used to choose the
seismonitor gain
The scale adjusts itself
according to the gain
chosen
Used to choose which
sensor types to show or
hide
Used to choose which
sensor type gain to adjust
with the Gain slider button
Line
Topographic views > Working with graphic views
428XL Users Manual Vol. 1 117
April 11, 2013
5
Note: Naturally, the Sensor noise on radio-type channels is not
viewed in real time. The radio-type channels noise display is
only refreshed each time you use the Look function.
Working with graphic views
To select one or more elements
With the mouse pointer resting on the first unit to be selected, press the
centre button of the mouse. Hold it down while dragging the pointer to
the last unit to be selected, then release it. A red background appears on
the selected units.
Figure 5-16 Selecting elements in graphic views
You can copy the selected area using the Control+C shortcut (the
message Copy Ready should appear at the foot of the window) and
paste it into the Absolute Spread Setup window to create a spread
setup.
If you launch a test with the buttons in the upper-right corner of the
graphic pane after selecting a set of units, the test is only performed on
the units selected. The selection is replicated (in the form of an absolute
spread description) in the Test Setup window accessed via the Functions
menu.
To select a single unit, use the same method with a sufficient zoom
factor.
To unselect, click anywhere in the graphic pane.
Release
Press
Line
Topographic views > Working with graphic views
118 428XL Users Manual Vol. 1
April 11, 2013
5
Zooming
With the mouse pointer resting anywhere in the graphic pane, press the
left button of the mouse. Drag the mouse pointer slowly in any
direction. This causes an elastic frame to show up that enlarges until you
stop dragging the mouse pointer. Release the mouse button. As a result,
the spread area encompassed in the elastic frame occupies the entire
right-hand pane.
Figure 5-17 Zooming
To view a channels QC data
With the mouse pointer resting on a receiver position, a tip box appears,
showing the type of the unit, its serial number and the QC result. The
relevant legend automatically appears at the top of the window, showing
the programmed limits for that test.
Figure 5-18 Viewing a channels QC data
Release
Press mouse left button
Mouse location
Only the QC
result chosen
with the option
button is shown.
Legend
Tip
LSI
FDU
Line
Topographic views > Working with graphic views
428XL Users Manual Vol. 1 119
April 11, 2013
5
Still with the mouse pointer resting on a receiver position, pressing the
right-hand button of the mouse causes a menu to pop up. Selecting
Properties opens a window showing details on the receiver position.
The Properties of an FDU include its identification, status, and all
available QC results. Also in the Properties of an LAUX are its IP
address and Booster power supply voltage (48 V).
Figure 5-19 Viewing Instrument properties
Right-click shortcuts
With the mouse pointer resting on an element in the graphic Instruments
view, the menu that pops up when you press the right-hand button of the
mouse may prompt one or more contextual shortcuts that let you display
or change properties or parameters of the element.
For example, you can turn a receiver position mute without going
through the Setup menu: you simply have to right-click on the desired
position and select Set Mute from the menu that pops up. The
relevant setup (e. g. the Layout setup in this example) is automatically
updated.
Right-clicking on any of the selection buttons at the top also brings up
the popup menu. This allows you, for example, to get traceability
information for the whole selection.
See also Detour (page 141).
Line
Topographic views > Working with graphic views
120 428XL Users Manual Vol. 1
April 11, 2013
5
Checkerboard view
With many units to be shown in the graphic view, the system may
decide to switch to the checkerboard view mode because there is no
room for all icons.
Figure 5-20 Checkerboard view
In the checkerboard view mode, icons are shrunk so that they can fit in
the graphic pane. Colours are still significant but control units (LAUX,
LAUL) and anomalies are emphasized so that you can spot them easily.
Then you can zoom in to see details.
All the FDUs making up a link are shrunk into a single rectangular icon
whose colour reflects the global QC of the link: faults (shown in red or
orange) take precedence over any other QC values, i. e. the links icon
turns red if any one status in the link is at fault.
Transverse path
LAUL FDU LAUX
Line
Topographic views > Working with graphic views
428XL Users Manual Vol. 1 121
April 11, 2013
5
Paths
Links can be viewed using the Cable Path button in Instrument views.
Figure 5-21
The following conventions are used for cable paths:
Green: OK.
Orange: Sensed, but a transmit error was encountered.
Red: A problem was encountered at the end of the cable.
The graphical view of paths helps you isolate any transmission trouble:
if the system finds the transfer time from a unit to the next is
inconsistent, the suspect path is displayed in red and, if the path is
included in the active spread, an alert window pops up when you click
on Go to launch an acquisition.
Viewing details
Double-clicking on a Detour or an FDU (or DSU) opens a detailed view
that allows you to see how many units are included in the Detour or the
Link.
Figure 5-22
End of a link
(connector)
Detour
Double-click Detail
Line
Topographic views > Working with graphic views
122 428XL Users Manual Vol. 1
April 11, 2013
5
Figure 5-23
Field equipment traceability
Right-clicking on a field unit (FDU, DSU, LAUL, LAUX, LAUR, etc.)
and selecting Get Traceability from the shortcut menu that pops up
causes the system to look for history records in the EEPROM memory
of that unit (first, you must go to Field Off then Field On). Right-
clicking on any of the selection buttons at the top also brings up the
popup menu and allows you to get traceability information for the
whole selection.
Figure 5-24
To see the traceability information, select
Look Traceability from the popup menu
on the same unit. This causes a window to
pop up, providing information on
manufacturing and any changes made
afterwards (Printed circuit board release,
list of change notices, Manufacturing date,
etc.). The traceability data is also available
in the jLog window (Results >Others >Line >SU traceability).
Double-click
Detail
Figure 5-25
Line
Numeric views >
428XL Users Manual Vol. 1 123
April 11, 2013
5
Numeric views
Use the View menu or toolbar buttons to choose which type of data to
display.
Numeric views display the available results in tables.
Figure 5-26 Sensor numeric view
Those results which do not fall within the limits specified in the Setup
menu are shown with a red background. If you wish to view only
those results, tick the Error Only option.
All columns are resizable. Adjust the width if any value fails to fit in.
(With the mouse pointer resting on the border of a column, left-click
and drag the border as required).
You can show or hide columns by right-clicking in any column
heading and selecting Customize (see Figure 2-25).
Left-clicking on the heading in any column causes the data in that
column to be sorted in ascending order. Clicking one more time
reverses the order, and so on.
After you connect a new unit to a line, the unit is added at the top of
the table. The list is not sorted until you click on a column heading.
The results are cleared each time a test function is launched.
Use scrollbar to view
hidden columns
Drag border
to resize
Click to filter
errors
Line
Numeric views >
124 428XL Users Manual Vol. 1
April 11, 2013
5
Figure 5-27 Sensor numeric view (continued)
Figure 5-28 Instrument numeric view
For an LAUL or LAUX, the Booster Failure column shows the status
of the +24 V and -24 V power supplies (a failure is reported if the
voltage is below 24 V) and the Leakage error column shows the result
from the leakage test (see LAU Leakage setup on page 153). For an LRU,
leakage cannot be measured.
For an LSI, two rows are displayed.
Figure 5-29 LSI channels
History numeric views allow you to view the Serial number, Line
number, Point number and geographical position of each unit, along
with the date and time when it was last seen (Last Access) and first seen
(Creation Date) in the survey.
Line
Histogram view >
428XL Users Manual Vol. 1 125
April 11, 2013
5
Histogram view
Results from Sensor tests and Instrument tests can be displayed in the
form of histograms in Histogram views.
Figure 5-30 Histogram view
Unless you choose the Manual range option, the horizontal scale is
automatically adjusted so that all samples can be shown. If you choose
Manual range, then the associated fields prompt the outermost values
of the horizontal scale, so that you can change them and adjust the scale
manually. (Click Apply to enable your settings).
If any bar straddles a specification limit marker in the bar chart, that part
of the bar which lies outside the specification range may be displayed
in blue (rather than red because this does not necessarily mean that
there are any results at fault). See Figure 5-31 (page 126).
Upper end
Lower end of
manual scale
Spec marker
Line
Histogram view >
126 428XL Users Manual Vol. 1
April 11, 2013
5
Figure 5-31
See also Bar charts (page 37).
Spec marker
Line
The Survey setup > General
428XL Users Manual Vol. 1 127
April 11, 2013
5
The Survey setup
In this section:
General (page 127)
Survey (page 128)
Point Code (page 130)
Sensor type (page 131)
General
You open this window by selecting Survey from the Setup menu.
Figure 5-32
It is used to provide information about the prospect area where the crew
is working. You access three categories of information using the three
tabs described in detail below: Survey (page 128), Point Code (page 130)
and Sensor type (page 131).
To make changes to any row in the list box, double-click on it, fill in the
fields above the list, then click Add or Change or Delete, as required.
To save the current settings, click Apply All with the lines turned OFF
(Field Off). This activates the choices made with all three tabs. In
contrast, whether the Lines are on or off, you can click Apply Sensor
to activate only the test result limits settings made using the Sensor tab.
List box
Input fields
Line
The Survey setup > Survey
128 428XL Users Manual Vol. 1
April 11, 2013
5
To revert to the former settings, click Reset instead of Apply.
Survey
To determine the crews prospect area, you have to specify the start and
end points of the lines, for each swath, together with any gaps caused by
obstacles or whatever. To do that youll click on the Survey tab. Note
that a tab is available for each swath name you have created in the
Config window (Swath setup on page 97).
Figure 5-33 Survey setup
Line
This index box is used to enter line numbers.
Tip: For example, entering 10-60/10 in the Line index box will
generate lines 10, 20, 30, 40, 60 in one click on Add.
Line numbers do not need to be arranged in any order. For instance you
may well wish to insert line 70 between lines 30 and 40: click line 30 in
the list box (its number appears in this index box), enter 70 in the index
box and click Add.
It is important, however, to understand that the graphic display in the
main window reflects the Survey setup. In other words, seismic lines
will be shown on the screen in the order in which they appear in this list
box, and not necessarily in the sequence they are laid out on the ground
or connected to the recording instruments. Go to the Preferences setup
(page 109) and select your preferred display option.
Receiver
points
100-103p1,106-110p1,111-115p2,116-120p3
Different Point Codes Gap
Point
Code
Line
The Survey setup > Survey
428XL Users Manual Vol. 1 129
April 11, 2013
5
Note: The traces recorded in the SEGD file will be in the same order
as in the Survey setup.
If line numbers are arranged in ascending or descending order, you can
easily reverse the order using the Reverse button as required.
Receiver Section
The Receiver Section field is used to assign a Point Code to each
Receiver Position in each line.
The syntax for the Point Code is p_ (example: p1). The Point Code
determines the type of sensor used. You define Point Codes in the
window accessed by clicking on the Point Code tab (see page 130).
On lines that do not use the same point code everywhere, you have to
split the description of the receiver section into as many series of
adjacent stakes with a common point code as necessary.
In the example provided in Figure 5-33 page 128, stakes 100 to 110
have the same point code (p1) but the series of receiver positions is split
because a gap with no channels is planned between stakes 103 and 106.
,
Figure 5-34
The stakes must be numbered in ascending order, usually with an
increment of 1 but you can use an increment other than 1.
This is the graphical display resulting from the above
example of survey description.
100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120
5
10
30
20
40
50
60
Line
The Survey setup > Point Code
130 428XL Users Manual Vol. 1
April 11, 2013
5
Tip: Example with an increment other than 1 for the receiver positions:
entering 100-150p1/10 as a receiver section will generate receiver
positions 100, 110, 120, 130, 140, 150 in one click on Add.
A receiver point may be used in multiple swaths, meaning that two or
more swaths may have a line portion in common. In that case the
description must be consistent in each swath. An example of
compatible receiver section descriptions would be
10:100-200p1 for Swath1
10:150-250p1 for Swath2
Point Code
Some applications require the use of different types of sensors within
the same spread. An example would be a transition zone survey, where
geophones are employed on land and hydrophones in water. See also
Working with DSU3-428 & DSUGPS links (page 162).
You assign a Point Code to a receiver section to specify which types of
sensors to use in that section (see Survey on page 128).
You define Point Codes in this window:
Figure 5-35 Point Code setup
Nb
Used to enter Point Code numbers. The system will automatically add
the letter p. You must define at least one Point Code.
s1+s2 1
Line
The Survey setup > Sensor type
428XL Users Manual Vol. 1 131
April 11, 2013
5
Label
Used to identify the Point Code in plain.
Sensor Type
Syntax: s_ (example: s1+s2).
Used to enter the sensor type or types associated with the point code.
Sensor types are defined in the window accessed by clicking on the
Sensor tab.
See also Advanced layouts (page 155).
Sensor type
When Sensor tests are to be performed, the electrical characteristics will
not necessarily be the same across the entire spread and therefore it may
be pointless to apply the same resistance, tilt (pulse response) and noise
test limits everywhere. Instead, the system allows several sets of limits
to be specified, each one appropriate to a particular sensor type. It is
then sufficient to define the zones in which each type of sensor can be
found, using Survey (page 128), and the system will automatically apply
the relevant limit for each measurement.
See also Working with DSU3-428 & DSUGPS links (page 162).
You can define different sensor types in this window.
Figure 5-36 Sensor setup
1
Line
The Survey setup > Sensor type
132 428XL Users Manual Vol. 1
April 11, 2013
5
Nb
Used to enter Sensor Types numbers. You must define at least one
Sensor Type.
Label
Used to identify the Sensor Type in plain.
Continuity
Upper and lower limit for the sensor impedance. Any channel with a
sensor impedance falling outside the range specified in the Min and
Max fields is reported at fault in sensor views (and shown in red in
graphic views).
Tilt
Maximum geophone tilt percentage. Alert threshold in the display of
Sensor Tilt test results.
Noise
Maximum RMS noise level. Alert threshold in the display of Sensor
Noise test results.
Leakage
Alert threshold in the display of Sensor Leakage test results. The
Leakage test measures the global leakage resistance between the
seismic channel and the earth ground.
Line
The Survey setup > Sensor type
428XL Users Manual Vol. 1 133
April 11, 2013
5
SEGD Code
Figure 5-37
Clicking the button associated with this field causes a list box to pop up
so that you can select the SEGD code of the type of sensor used. This
code has no effect on the performance of the system. It is only written
to tape (byte 21 in block 1 of the Trace Header Extension).
Line
The Layout setup > General
134 428XL Users Manual Vol. 1
April 11, 2013
5
The Layout setup
In this section:
General (page 134)
Markers (page 135)
Auxiliary channels (page 139)
Detour (page 141)
Mute channels (page 144)
General
Figure 5-38
Having defined the lines that will be used in the survey, using The
Survey setup (page 127), it is necessary to provide information for the
central unit to capture the actual layout of those lines, using the layout
setup window.
You open this window by selecting Layout from the Setup menu.
You dont have to supply the location of each and every element in the
survey: you only have to create a marker (fully identified with its unit
type, serial number, topographic stake number) in each line segment.
This will enable the system to automatically see how your field
equipment is deployed. In this window, you also specify the location of
List box
(empty)
Input fields
Line
The Layout setup > Markers
428XL Users Manual Vol. 1 135
April 11, 2013
5
auxiliary channels, detours, and inactive channels if any. You also have
to describe all radio telemetry units.
Note: The selection you make by clicking on any row in the list box is
reflected in the main windows graphic view: the cursor
automatically moves to the selected unit.
To make changes to any row in the list box, double-click on it, fill in the
fields above the list, then click Add or Change or Delete, as required.
To save and enable your changes, click Apply. (To revert to the former
settings, click Reset instead).
Markers
After the links are deployed at the planned positions on the ground, you
need to know the exact location of at least one unit (FDU, LAUL,
LAUX or LRU) in each line segment actually connected, so that you
can create a marker for each line segment, by specifying the serial
number of that unit, the associated receiver position and other
parameters described below. After you create the appropriate markers
on each line, in this setup window, the system is able to collect the status
of all units connected, as soon as lines are turned on. Then it will
continually update the view in the main window.
.
Figure 5-39 Marker setup
Tip: To enter a marker, you can drag and drop a unit from the main
window (Instrument graphic view) to the markers list box.
At least one
marker on
each line
Line
The Layout setup > Markers
136 428XL Users Manual Vol. 1
April 11, 2013
5
Box Type
As its label suggests, this field is used to choose the type of unit (LCI-
428, LCI-G, LAUX-428, etc.). Select the type actually implemented at
the location chosen as a marker. Note that setting a marker on an
LAUX-428 used as repeater in a Transverse allows displaying it at the
appropriate location in the Line window.
S. N.
Serial number of the unit actually implemented at the location chosen
as a marker.
Line Name
Used to specify the number of the Line the marker is attached to.
IMPORTANT
Each line should have at least one marker. If the line is composed of
several segments, enter a marker on each segment.
Below are two examples:
Two line segments with a transverse cable used as a detour
Figure 5-40
Transverse cable
Enter one marker for this
line segment
Enter another marker for
this line segment
LAUX LAUX
Line
The Layout setup > Markers
428XL Users Manual Vol. 1 137
April 11, 2013
5
End-to-end line segments with no wireline connection
Figure 5-41
Point Nb
Used to specify the Point Number (i. e. stake number) of the location
used as a marker.
Note: By convention, an LAUL or LAUX assumes the number of the
first topographic stake encountered on its Low side.
(Remember topographic stakes are defined in the Survey
Setup).
Figure 5-42
Channel Nb
Used to specify the channel number implemented at the location used
as a marker, in the case of a multi-channel unit.
N
o

w
i
r
e
l
i
n
e

c
o
n
n
e
c
t
i
o
n
Enter one marker for
this line segment
Enter another marker
for this line segment
M
a
r
k
e
r
M
a
r
k
e
r
To set a marker on this
LAUX, enter 111 as Point
Number
110 111 112 113
LAUX
Line
The Layout setup > Markers
138 428XL Users Manual Vol. 1
April 11, 2013
5
Marker Increment
Typically, the Marker Increment is set to 1, meaning that a receiver
channel is deployed at each stake number.
Figure 5-43
To implement a Receiver Position (i. e. a receiver channel) every n
stake numbers on a line segment, enter n into the Marker Increment
field. See Logical line mapped with several physical lines on page 157.
Reversed
Typically, the Reversed button should be left unticked.
This button is used to reverse the direction of the assignment of receiver
channels to receiver positions over a line segment. See Snaking layout
(page 160).
FDU
xxxx
Line
10
M
a
r
k
e
r
109 110 111 112 113 114 115
FDU-428 xxxx 10 112 1
LAUX
428
Line
The Layout setup > Auxiliary channels
428XL Users Manual Vol. 1 139
April 11, 2013
5
Auxiliary channels
Figure 5-44 Auxiliary channel setup
The analog signals you want to record as auxiliary traces are fed to some
FDUs, which may be connected direct to the High or Low Line port of
the LCI-428 or LCI-G, or located anywhere in the spread. Use this
window to describe your auxiliary channels.
Tip: To enter an auxiliary channel, you can drag and drop a unit from
the main window (Instrument graphic view) to the list box.
In the topographic view of the spread, all auxiliary channels are
gathered at the record unit position.
Nb
Row number in the list box. This identification number is used in the
Instrument tests (page 218) setup to specify which auxiliary channels to
test.
Label
Used to assign a name to the Auxiliary channel (e. g. Pilot). That label
is used in the Operation window to describe the type of processing to
perform to generate an auxiliary trace. See Correl (correlation) With
(page 260).
Line
The Layout setup > Auxiliary channels
140 428XL Users Manual Vol. 1
April 11, 2013
5
Box Type
Used to choose the type of unit used for this auxiliary channel
(FDU408, FDU-428, FDU2S, etc.). If an AXCUL box is used, choose
the FDU408 type. With a Default Line Data Rate (page 90) at 16Mb/s,
any line segment including FDU408 channels will not be visible unless
you use The Form Line setup (page 226) to set the data rate to 8 Mb/s on
that segment.
S. N.
Used to enter the Serial Number of the unit used for this auxiliary
channel.
Channel Nb
Used to specify the channel number of this auxiliary channel, in the case
of a multi-channel unit.
Gain
Used to choose the preamplifier gain for this auxiliary channel. See the
gain code table on page 147.
Input from
Spread: choose this option if the auxiliary signal is fed to an FDU
within a line in the spread or connected to the LCI. (With this option,
the Device Nb field is not used).
DSD: choose this option if the auxiliary signal is a vibrator motion
signal from a DSD. The associated Device Nb field allows you to
specify which DSD enclosure this auxiliary channel is attached to.
You have to enter the Vib number from the Fleet function in the
VE464 window or from the Look function in the VE432 window. See
SQC Dump mode (page 348) or SQC Dump mode with VE432
(page 361).
DPG: this option is used if two or more VE432 vibrator controllers
(DPGs) are attached to the system (for example if vibrator fleets are
Line
The Layout setup > Detour
428XL Users Manual Vol. 1 141
April 11, 2013
5
used in Slip-Sweep mode). The associated Device Nb field allows
you to specify which DPG enclosure this auxiliary channel is
attached to. You have to enter the DPG Module number that is
prompted when you run the Look function in the VE432 window.
With VE432 DPGs working in Slip-Sweep mode, each type of
auxiliary signal supplied by the DPGs must be identified with the
same name for each DPG, in the Label field (e. g. Pilot).
Figure 5-45 Auxiliary channels from VE432 DPGs in Slip-Sweep mode
Comments
Used to enter any comment you think necessary, for example if the
Label is not self-explanatory.
Detour
Use this window to specify the location of detours, if any, between
receiver positions. All units within a detour will be inactive (unused).
Figure 5-46 Detour setup
Same
name
Two
DPGs
Same
name
Last active channel
on Low side
First active channel
on High side
Line
The Layout setup > Detour
142 428XL Users Manual Vol. 1
April 11, 2013
5
Below is a typical example where a detour is set between two adjacent
receiver positions.
Figure 5-47
To create that detour, you can use the Detour setup window or the
shortcuts available by right-clicking in the Instrument topographical
view.
(1) Right-click on last active unit on the Low side and choose Set low
box of detour from the popup menu. A flag should appear on that unit.
(2) Right-click on first active unit on the High side and choose Set
high box of detour from the popup menu.
Figure 5-48
Unused unit
Last active unit on Low
side (enter its Serial No.
into Low S. N. field)
First active unit on
High side (enter its
Serial No. into High
SN field)
1068 1069
Denotes a
detour
Denotes low end of
detour
(1) (2)
Line
The Layout setup > Detour
428XL Users Manual Vol. 1 143
April 11, 2013
5
This automatically creates the detour in the setup window (see the
description of each field below). Detours are also visible in the Detour
numeric view.
Low Box Type
Used to specify the Type of the adjacent active unit located ahead of
(on the Low side of) the detour.
Low S. N.
Used to specify the Serial Number of the adjacent active unit located
ahead of (on the Low side of) the detour, meaning that the unit on the
other side is the Low end of the detour.
Low Chann. Nb
In the case of a multi-channel unit, use this field to specify the adjacent
active channel ahead of (on the Low side of) the detour, meaning that
the channel on the other side is the Low end of the detour.
High Box Type
Used to specify the Type of the adjacent active unit located after (on
the High side of) the detour.
High S. N.
Used to specify the Serial Number of the adjacent active unit located
after (on the High side of) the detour, meaning that the unit on the other
side is the High end of the detour.
High Chann. Nb
In the case of a multi-channel unit, use this field to specify the adjacent
active channel after (on the High side of) the detour, meaning that the
channel on the other side is the High end of the detour.
Line
The Layout setup > Mute channels
144 428XL Users Manual Vol. 1
April 11, 2013
5
Stop Marking
Typically, the Stop Marking button should be left unticked.
This button is only used where a change is required in the automatic
assignment of receiver channels to receiver positions. (See also
Advanced layouts (page 155)).
Mute channels
Figure 5-49 Mute setup
Use this window to specify the location of mute receiver points, if any.
The channel from a mute receiver point is acquired, but its data is
zeroed. In the case of multi-sensor receiver point, all channels are mute.
Tip: To enter a mute receiver point, you can drag and drop it from the
main window (Instrument graphic view) to the list box.
Line Name, Point Number
Used to specify the location of a mute unit.
Line
The Spread Type setup > General
428XL Users Manual Vol. 1 145
April 11, 2013
5
The Spread Type setup
In this section:
General (page 145)
Absolute spreads (page 146)
Generic spreads (page 148)
General
You have to specify the complete acquisition spread to be used for each
and every shot. The programming of these spreads can be done not only
automatically via SPS files in the Log window (see Importing an SPS file
on page 583) but also manually, using the editing tools provided by the
GUI.
Figure 5-50 Spread type setup
In either case, a shorthand method of defining all of the channels to be
used is available in the 428XL. The concept of a Generic Spread
(generic means Standard) is especially helpful for manual
programming. The alternative method uses Absolute Spreads, which
are more suitable for automated programming.
To define a new spread in the list box, fill in the description,
identification number and label fields, then click Add.
Enter the description of
your spread here
Line
The Spread Type setup > Absolute spreads
146 428XL Users Manual Vol. 1
April 11, 2013
5
To make changes to any row in the list box, double-click on it, fill in the
fields above the list, then click Add or Change or Delete, as required.
To save and enable your changes, click Apply. (To revert to the former
settings, click Reset instead).
Absolute spreads
An absolute spread is defined in terms of line and stake numbers, for
example: Line 10, from stake 101 to stake 103, then from stake 106 to
stake 115. (It therefore follows that you need to define a completely new
absolute spread every time the acquisition spread moves even by a
single receiver point). Note that a tab is available for each swath name
you have created in the Config window (Swath setup on page 97),
allowing you to enter the description of the spread in each swath.
Figure 5-51 Absolute spread setup
Enter a colon (:) between the Line Number and the Receiver positions.
Enter a hyphen (-) to specify a series of Receiver positions.
Enter a comma (,) to specify a gap between two or more Receiver
positions (or to specify series of Receiver positions with different
channel gain codes (e. g. 106-110g1,11-115g2).
To describe another Line or set of Lines, press Return or type a slash
character (/).
The system automatically adds as (abbreviation for Absolute
Spread) ahead of the Identification Number in the list box. Note that
Gain code
10:101-103g1,106-115g1
20:101-103g1,106-115g1
30:101-103g1,106-115g1
Line
The Spread Type setup > Absolute spreads
428XL Users Manual Vol. 1 147
April 11, 2013
5
each Identification Number is unique, so you cannot reuse the same
spread number in multiple swaths.
Choose the gain code from the table below.
Tip: A simple way of creating an absolute spread type consists of
selecting the desired spread in the graphic view with the mouse,
copying the selected area and pasting it into the Spread Type setup
window. See Figure 5-16 page 117.
You can benefit from the extra large acquisition capacity of the 428XL
to speed up shooting, by defining a Superspread in the Absolute
Spread setup and using it in the Operation window. The Superspread
itself is an absolute spread that encompasses several successive
absolute spreads. With a Superspread, you save time because after the
Superspread is formed, line forming is not required every time the
active spread moves (unless the Aux descriptor changes). See
Superspread (page 278).
Figure 5-52 Superspread
Note: If you are using DSUGPS links, it is recommended to use a
Superspread so that the DSUGPS units located outside the
active spread can send their GPS data to the central unit.
Table 5-1
Gain Code Input scale FDU DSU3-428 & DSU1-428
g1 1600 mV 0 dB 5 m/s
g2 400 mV 12 dB
Superspread
Line
The Spread Type setup > Generic spreads
148 428XL Users Manual Vol. 1
April 11, 2013
5
WARNING
When you are using a Superspread, the Gain code for any given trace
must be the same in all individual spreads making up the Superspread,
and in the Superspread itself (because the acquisition of a trace must be
done with the Gain code specified for that trace in the active individual
spread).
Generic spreads
A generic spread describes the pattern of the active channels. The
fundamental difference between an absolute and a generic spread is that
generic definitions are always relative. You may wish to define one
generic spread to be used throughout the life of a crew.
To take a textbook example, a symmetrical split spread could be defined
as a number of lines with 100 stakes, a gap of 2 and then another 100
stakes. There is nothing in the basic definition that says where the
spread should be implemented. If one or more receiver units fall outside
the boundaries or within a gap specified in the Survey Setup, those
channels, will not be implemented.
Figure 5-53
G
e
n
e
r
i
c

s
p
r
e
a
d
Generic Line
Generic Line
Generic Line
Generic Line
Line
The Spread Type setup > Generic spreads
428XL Users Manual Vol. 1 149
April 11, 2013
5
Line
Figure 5-54
The description of generic spreads makes use of Generic Line Types
that you define in this window. When you describe a Generic Line Type
you assign a gain code to a set of channels. See the gain code table
above.
Note: If any receiver units are laid out between receiver points, they
must be described as Skipped channels (page 155) or
detours in the The Layout setup (page 134).
Note: To skip receiver points, enter rs in the description.
Use brackets to repeat sets of two or more gain codes, with a repetition
factor placed ahead of the leading bracket. Below are two examples:
10(g1+g2) will describe 10 pairs of channels where, in each pair, the
1st channel has a 0 dB gain and the 2nd channel a 12 dB gain.
10(g1+rs) will describe 10 pairs of channels where, in each pair, the
1st channel has a 0 dB gain and the 2nd channel is skipped.
The system automatically adds the letter "l" ahead of the Identification
Number in the list box.
50g1+50g2
Line
The Spread Type setup > Generic spreads
150 428XL Users Manual Vol. 1
April 11, 2013
5
Spread
Figure 5-55
When you describe a Generic Spread type you assign a generic Line
Type to a set of lines. Line types are defined in the Generic Line
window.
To skip lines, enter ls in the description.
Use brackets to repeat sets of two or more lines, with a repetition factor
placed ahead of the leading bracket. For example 10(l1+ls) will
describe 10 pairs of lines where, in each pair, the 1st line is L1-type and
the 2nd is skipped.
The system automatically adds sd (abbreviation for Spread
Descriptor) ahead of the Identification Number in the list box.
10l1+10l2
Line
The Look setup >
428XL Users Manual Vol. 1 151
April 11, 2013
5
The Look setup
You open this window by selecting Look
Setup from the Setup menu. The Look
function is used to see if any new units are
connected, so as to display them in the Line
main window.
Auto Look
Disabled: Each LAU will only identify the
connected units when you go to Field On
or you click on the Look button.
If a disruption arises, only the units encountered on the connected line
segment are re-identified by the LAU.
In the event of a transmission sync error, a red path appears at the
output of the LAU controlling the line segment affected. You have to
launch a manual Look to re-identify the FDUs located between the
LAU and the disruption.
Enabled (default): This enables the field update mode (each LAU
continually looks for any new units connected so as to identify them).
Note: In case of a disruption along a Line, the Auto Look
automatically rewakes the spread and, if necessary, reroutes the
data towards the portion of the line that is connected. In
contrast, a disruption along the Transverse is not recovered the
same way: the Auto Look will not reform the crashed spread
and reroute the data (instead, a Field Off/Field On is required).
On a line segment including an LSI, the automatic look is disabled:
to see new FDUs, you must use manual Look in that case.
Figure 5-56
Line
The Look setup >
152 428XL Users Manual Vol. 1
April 11, 2013
5
With Tests
After each Look, whether automatic or manual, the Sensor tests you
choose with these buttons (Resistance, Tilt, Leakage) will be performed
on the FDUs identified.
The Resistance and Tilt tests are selected by default.
In field update mode, if the Resistance value exceeds the specified
limit (e. g. with nothing connected on the channel input), the Tilt and
Leakage tests are not performed, even if they are selected in this setup.
Line
LAU Leakage setup >
428XL Users Manual Vol. 1 153
April 11, 2013
5
LAU Leakage setup
A leakage sensor circuitry in each LAU senses any leakage arising
between a conductor in the telemetry cable and ground.
The LAU Leakage command available from the Setup menu allows you
to set an alert level. If the leakage current exceeds that alert level, the
LAU reports a fault to the GUI. As a result, the LAU is shown in red in
the Instrument topographic view and a Leakage error appears in the
Instrument numeric view for that LAU.
Figure 5-57
The Connections column in the Instruments graphical view, and the
properties of an LAU (available on a right-click) tell you which port(s)
is (are) powered up, so you can see which port is affected by leakage. In
the case of an LAUX, you can use the Form Line function to enable/
disable its low or high port in order to discriminated between the two
ports.
In each LAU, a leakage measurement is taken every 5 seconds, using
the test circuitry shown on the simplified diagram below.
Leakage current
displayed in red if
exceeding alert level.
Tells you which port
is affected
Available from
Setup menu
Line
LAU Leakage setup >
154 428XL Users Manual Vol. 1
April 11, 2013
5
Figure 5-58
Note: Leakage between the two telemetry pairs is not revealed by this
test circuitry, but transmission may be lost as a result of such leakage.
+24 V
-24 V
ADC
FDU
Pwr
Sply
6.3 V
2.7 V
FDU
R
sense
Leakage
current
Telemetry pair
Telemetry pair
Leakage
Leakage
current
LAUL
or
LAUX
Housing
Line
Advanced layouts > Skipped channels
428XL Users Manual Vol. 1 155
April 11, 2013
5
Advanced layouts
Some fields or options (like Marker Increment, Stop Marking,
Reversed) in the Setup windows make the deployment of 428XL
field electronics extremely flexible. Below are textbook examples of
advanced layouts that can easily be implemented:
Skipped channels (page 155).
Logical line mapped with several physical lines (page 157)
Detour with skipped receiver points (page 159)
Snaking layout (page 160)
Skipped channels
You may want to skip channels because, for example, you want to
increase the receiver spacing without changing the spacing of your
FDUs. In that case, the inactive units laid out between the active
receiver points must be specified as Skipped Channels in the Point
Code used, by adding the code cs in the Sensor Type field (in the
Survey setup window). Note that this does not work with FDU2S units.
Example with a Marker on an FDU
Figure 5-59
Note: A distinction must be made between skipping channels and
skipping receiver points. To skip some receiver points, you
LAUX
M
a
r
k
e
r
FDU
xxxx
2 skipped
channels
2 skipped
channels
110 111 109
FDU xxxx 10 110
1 s1+cs+cs 2 skipped
Line
Advanced layouts > Skipped channels
156 428XL Users Manual Vol. 1
April 11, 2013
5
may use the Spread setup (see page 149) or the Detour setup
(see page 159).
Example with a Marker on an LAUX
The system uses the following rule in interpreting the Point Code:
if an LAUX is used as a Marker, the Sensor Type (e. g. s1) specified
in the Point Code is assigned to the first channel encountered on the
Low side of the LAUX (if none is found on the Low side, a virtual
channel is assumed).
In the example below, the Point Code will be interpreted by the system
as follows:
On line 10, using s1+cs+cs as a Point Code assigns s1 to the first
channel encountered on the Low side of the LAUX,
On line 20, using s1+cs+cs as a Point Code assigns s1 to the third
channel on the High side because none is found on the Low side.
Figure 5-60
LAUX
M
a
r
k
e
r
LAUX
M
a
r
k
e
r
yyyy
xxxx
Line
10
Line
20
2 skipped
channels
2 skipped
channels
2 skipped
channels
2 skipped
channels
A virtual channel is assumed on the Low side
110 111 109
LAUX xxxx 10 109 1 s1+cs+cs 2 skipped
LAUX yyyy 20 109
110 111 109
Line
Advanced layouts > Logical line mapped with several physical lines
428XL Users Manual Vol. 1 157
April 11, 2013
5
In the example below, do not use the LAUX as a Marker. Use an FDU
instead.
Figure 5-61
Logical line mapped with several physical lines
Figure 5-62
The flexibility of channel assignment in the 428XL allows you to split
a line into several segments laid out side by side (or group several
segments laid out side by side into one logical line). For example, this
LAUX
xxxx
M
a
r
k
e
r
Line
10
2 skipped
channels
2 skipped
channels
FDU xxxx 10 109
1 s1+cs+cs 2 skipped
110 111 109
FDU
xxxx
FDU
yyyy
FDU
zzzz
M
a
r
k
e
r
M
a
r
k
e
r
FDU
nnnn
Line
10
Line
10
Line
10
Line
20
Line
20
M
a
r
k
e
r
109 110 111 112 113 114 115
FDU-428 xxxx
FDU-428 yyyy
10
10
109
110
3
3
FDU-428 zzzz 10 111 3
LAUX
428
LAUX
428
LAUX
428
LAUX
428
LAUX
428
Line
Advanced layouts > Logical line mapped with several physical lines
158 428XL Users Manual Vol. 1
April 11, 2013
5
lets you shorten the receiver spacing without changing the spacing of
your FDUs.
In the Marker setup window, set a marker assigning a known FDU to
a known receiver position on each segment to be grouped, with the same
Line number and the same Marker Increment (chosen to be equal to the
number of segments).
When you go to Field On, each split line will act as a single line.
Below is an example where three segments are grouped into one logical
line (or a line is split into three segments).
Note: The segments making up the split line dont need to be attached
to the same LCI board.
Note: The Marker position can be chosen elsewhere within each line
segment, that is on any FDU belonging in the line segment. For
instance, if it is easier for you to know the position of FDU No.
nnnn, you may just as well set the marker on it rather than FDU
No. zzzz.
Note: If any detour is implemented in a split line, it must be described
in each segment making up the split line.
Figure 5-63
xxxx
yyyy
zzzz
Line
10
10
10
M
a
r
k
e
r
M
a
r
k
e
r
vvvv
nnnn
uuuu
M
a
r
k
e
r
M
a
r
k
e
r
M
a
r
k
e
r
M
a
r
k
e
r
FDU-428 xxxx
FDU-428 yyyy
FDU-428 zzzz
FDU-428 nnnn
FDU-428 uuuu
FDU-428 vvvv
109 110 111 112 113 114 115 116
Line
Advanced layouts > Detour with skipped receiver points
428XL Users Manual Vol. 1 159
April 11, 2013
5
Detour with skipped receiver points
Figure 5-64
To implement this example:
You have to set two markers (one on either side of the detour);
In the Detour setup, you must choose the Stop Marking option. This
will actually assign FDU No. yyyy to Receiver Position 114.
M
a
r
k
e
r
FDU
yyyy
FDU
xxxx
M
a
r
k
e
r
Line
10
109 110 111 112 113 114 115
FDU-428 xxxx
yyyy
FDU-428
FDU-428 xxxx
FDU-428 yyyy
10
10
110
114
1
1
Line
Advanced layouts > Snaking layout
160 428XL Users Manual Vol. 1
April 11, 2013
5
Snaking layout
Figure 5-65
An example of snaking layout is shown above. In the Detour setup
window, create a detour on each change in the direction of the
assignment of receiver channels to stake positions, each time choosing
the Stop Marking option. In the Marker setup window, be sure there
is a marker on either side of each detour, using the Reversed option
where channels are assigned in decreasing order of stake positions.
The Marker position can be chosen elsewhere within each line segment,
that is on any FDU, LAUL or LAUX belonging in the line segment. For
FDU
uuuu
FDU
vvvv
FDU
yyyy
FDU
zzzz
LAUX
xxxx
(*)
(*)
M
a
r
k
e
r
M
a
r
k
e
r
M
a
r
k
e
r
FDU
nnnn
(*) Those FDUs
must be declared
with the Stop
Marking option
ticked.
Line
10
Line
20
Line
30
109 110 111 112 113 114
LAUX-428 xxxx
FDU-428 vvvv
10
20
108
113
1
1
FDU-428 zzzz 30 109 1
FDU-428 uuuu
vvvv
FDU-428
FDU-428 yyyy
zzzz
FDU-428
Line
Advanced layouts > Snaking layout
428XL Users Manual Vol. 1 161
April 11, 2013
5
instance, if it is easier for you to know the position of FDU No. nnnn,
you may just as well set the marker on it rather than FDU No. vvvv.
The snaking topology cannot be used in place of any secondary
transverse.
Figure 5-66
Secondary
Transverse
YES NO
LAUX
428
LAUX
428
LAUX
428
LAUX
428
LAUX
428
LAUX
428
Line
Working with DSU3-428 & DSUGPS links > DSU3-428 topology
162 428XL Users Manual Vol. 1
April 11, 2013
5
Working with DSU3-428 & DSUGPS links
In this section:
DSU3-428 topology (page 162)
Acquisition using DSU3 channels (page 163)
DSU3-428 in the Survey Setup (page 164)
DSU3-428 in the Layout Setup (page 166)
DSU3 in the Spread Setup (page 167)
DSU3 in the Test Setup (page 168)
DSUGPS Setup menu (page 169)
DSUGPS firmware upgrading (page 171)
DSU Form Line function (page 174)
DSU Sensor view (page 174)
DSU Instrument view (page 175)
DSU Numeric view (page 177)
DSU Seismonitor (page 178)
DSU3 tilt correction (page 179)
DSU3-428 topology
The channel assignment in the
DSU3 is as follows:
Channel 1 is assigned to the
Vertical sensor,
Channel 2 is assigned to the
Inline horizontal sensor,
Channel 3 is assigned to the Crossline horizontal sensor.
For 3C polarity conventions see 428XL Users Manual Vol. 3.
Arrow engraved
in DUS3 takeout
ch1
(V)
ch2
(I)
ch3
(C)
Figure 5-67 DSU3-428 topology
Line
Working with DSU3-428 & DSUGPS links > Acquisition using DSU3 channels
428XL Users Manual Vol. 1 163
April 11, 2013
5
The arrow engraved in the cable takeout overmould points to the
positive direction of the Inline horizontal axis of the DSU3.
Acquisition using DSU3 channels
General features
To work with DSU3 lines, you must enable that option in the Install
window.
DSU3 links can be used jointly with analog-sensor units (FDU, etc.)
within a spread, but a DSU3 line segment (i. e. a portion of line that
includes DSU3 channels and is delimited by two LAUs) should include
only DSU3 channels. The DSU3 is compatible with all 428XL
components and with QC tools (eSQC Pro, eSGA).
DSU3 channels use the same Filter and Sample Rate as FDU channels.
While performing seismic acquisition, the LAU controlling the DSU3
corrects all inherent errors (attributable to the construction or geometry
of the DSU3). It does not correct Tilt errors attributable to planting, nor
does it remove the offset resulting from the tilt angle (that offset is
removed by the central unit).
In order to see if DSU3 units are properly planted, a Tilt test should be
done from time to time (this can be automated with the Auto Look
option; see The Look setup on page 151). The Tilt test will return the tilt
angle of the I- and C-channels, that is the angle between the direction
axis of the channel and the horizontal plane. For 3C polarity
conventions, see 428XL Users Manual Vol. 3. The results from the Tilt
test are recorded in the Trace Header. This allows corrections to be
made at a later date. See DSU3 tilt correction (page 179).
The Descale Multiplier recorded in the Scan Type Header allows
recorded samples to be converted into mV. See Users Manual Vol. 3
(Reference Information).
The sensor Sensitivity is recorded in the Trace Header (452 mV/m/s
2
, or
142 mV/m/s for Tilt and Gravity tests). See Users Manual Vol. 2
(SEGD format).
Line
Working with DSU3-428 & DSUGPS links > DSU3-428 in the Survey Setup
164 428XL Users Manual Vol. 1
April 11, 2013
5
DSUGPS specific features
If you are using DSUGPS links, it is recommended to use a
Superspread (page 278) so that the DSUGPS units located outside the
active spread can send their GPS data to the central unit.
Use the DSUGPS Setup menu (page 169) to enter the position of the
GPS reference station attached to the LCI-428, and set accuracy
parameters.
16-Mbps line data rate is supported with no restrictions.
8-Mbps line data rate is allowed with the following restrictions:
- either disabling Auto Look (page 151) mode if DSUGPS
connected after last LAUL.
- or keeping Autolook mode if LAUL connected after last
DSUGPS in the line.
DSU3-428 in the Survey Setup
Sensor
If the system is configured for operation with both FDU and DSU
channels (in the Install window), a distinct setup window is available
for each type of channel.
.
Figure 5-68
Line
Working with DSU3-428 & DSUGPS links > DSU3-428 in the Survey Setup
428XL Users Manual Vol. 1 165
April 11, 2013
5
You have to define three Sensor Types (s1, s2, s3), i. e. one for each
sensor in the DSU3, using the Sensor tab in the Survey Setup window.
The system assigns the Sensor Types as follows:
s1 is automatically assigned to Channel 1 (Vertical);
s2 is automatically assigned to Channel 2 (Horizontal, Inline);
s3 is automatically assigned to Channel 3 (Horizontal, Crossline).
In the Tilt (Degrees) and Noise (m/s
2
) fields, enter the desired
limits for the results of Sensor tests. Note that no Instrument test results
will be available for DSUs that return a Tilt error.
Choose the appropriate SEGD code for each axis. The SEGD code is
not used by the GUI. It is only written to tape (byte 21 in block 1 of the
Trace Header Extension).
Point Code
Figure 5-69
After defining three Sensor Types for a DSU3, define its Point Code as
s1+s2+s3.
1 DSU3 channels s1+s2+s3
Line
Working with DSU3-428 & DSUGPS links > DSU3-428 in the Layout Setup
166 428XL Users Manual Vol. 1
April 11, 2013
5
DSU3-428 in the Layout Setup
Marker
You must set a marker on one of the DSU3-428s in each DSU3-428 line
segment.
In the case of a logical line made up of N physical split lines, the
Increment should be set to 1 +3(N 1). For example:
2 physical split lines forming a single line: set the Increment to 4;
3 physical split lines forming a single line: set the Increment to 7;
etc.
Figure 5-70
Aux
You cannot use any DSU3 for auxiliary channels. FDUs must be used
for auxiliary channels, even if all seismic channels are DSU channels.
Detour
If any DSU3 is included in a detour, all three channels are part of the
detour.
DSU3 #zzzz
Line
10
Line
10
Line
10
Line
20
Line
20
109 110 111 112 113 114 115
DSU3-428 xxxx
yyyy
10
10
109
110
7
7
zzzz 10 111 7
LAUX
428
LAUX
428
LAUX
428
LAUX
428
LAUX
428
M
a
r
k
e
r
DSU3 #yyyy
M
a
r
k
e
r
M
a
r
k
e
r
DSU3 #xxxx
DSU3 #nnnn
DSU3-428
DSU3-428
Line
Working with DSU3-428 & DSUGPS links > DSU3 in the Spread Setup
428XL Users Manual Vol. 1 167
April 11, 2013
5
Snaking layouts are allowed. In the example below, you must set a
Detour with DSU3 No. 4149963 (point No. 1216) as the last active
channel at the Low end of the detour, and DSU3 No. 4151751 (point
No. 1216) as the first active channel at the High end of the detour. Also
you must activate the Stop Marking option.
Figure 5-71
Note: In the Marker setup, you have to set a marker on Line 160 (for
example assign point No. 1216 to DSU3 No. 4151751), and activate the
Reversed option for that marker. See also Snaking layout on page 160.
Mute
If a DSU3 is planted at a muted receiver point, all three channels are
mute. The maximum allowable number of mute receiver points is 1024.
DSU3 in the Spread Setup
Use the same syntax as with FDU channels to describe receiver
positions.
DSU3-428 channels have a single input scale (gain code G1).
If you are using DSUGPS links, it is recommended to use a Superspread
(page 278) so that the DSUGPS units located outside the active spread
can send their GPS data to the central unit.
No. 4149963
No. 4151751
Line
Working with DSU3-428 & DSUGPS links > DSU3 in the Test Setup
168 428XL Users Manual Vol. 1
April 11, 2013
5
DSU3 in the Test Setup
Naturally, the channel electronics and the accelerometers in a DSU3 are
tested as a whole assembly, never as separate functions. Therefore, the
distinction between Instrument and Sensor tests is not significant
for a DSU. However, because DSU links can be used jointly with FDU
links in a spread, some DSU tests are regarded as Instrument tests and
others as Sensor tests.
The following tests are available for the DSU:
- Sensor tests: Tilt (degrees), Noise (m/s
2
).
- Instrument tests: Distortion, Gain/Phase, Crosstalk, Gravity.
DSU3-428 channels have a single input scale (gain code G1).
If the spread you specify in the Test Setup includes both FDU and DSU3
channels, the system only applies the test to the channels that support
that test, with the relevant test limits. For the syntax to be correct in the
Absolute Spread Setup, you have to specify a gain code (e. g.
10:100-150g1) but the system actually uses the gain selected with the
Gain option button.
The limits for DSU3 Instrument test results are contained in files (one
for each allowable sample rate) the format of which is described in
428XL Users Manual Vol. 2. The Instrument test limits for the DSU3
are distinct from those for the FDU. For the factory-settings of
Instrument test limits, see Specifications in Users Manual Vol. 3.
The limits for Sensor tests are user-selected in the Survey Setup (see
Sensor on page 164).
Line
Working with DSU3-428 & DSUGPS links > DSUGPS Setup menu
428XL Users Manual Vol. 1 169
April 11, 2013
5
DSUGPS Setup menu
Figure 5-72 Base Position tab
The Base Position fields are used to enter the position Easting,
Northing and Elevation (metres) of the antenna of the GPS reference
station attached to the LCI-428 and used to lock its clock to the GPS
time.
WARNING
After choosing the projection in The Projection Type setup (page 411) in
the jPositioning window, go to Off Line in the jConfig window. In the
jLine window, click on Apply in the DSUGPS setup (Figure 5-72) to set
the GPS reference station position (Base Position). Then go to On Line
in jConfig.
Figure 5-73 Accuracy tab
The Accuracy tab allows you to set the maximum allowable Azimuth
(adjustable from 3 to 5) and Position (1 to 2 m) deviations for
convergence criteria calculations. As a result, the antenna icon of a
DSUGPS will show in yellow in the instrument view if its Azimuth
Line
Working with DSU3-428 & DSUGPS links > DSUGPS Setup menu
170 428XL Users Manual Vol. 1
April 11, 2013
5
Standard Deviation or Position Standard Deviation exceeds the limit
calculated from your Accuracy settings, otherwise green. See also DSU
Numeric view (page 177).
Use the charts below to determine the appropriate setpoints, depending
on how long you can keep your DSUGPS sensors stationary.
For example, if you set the Azimuth accuracy to 3.5 and the Position
accuracy to 1.5 m, then at least 95% of DSUGPS sensors will achieve
convergence after remaining stationary for 7 hours.
Figure 5-74 Max convergence time vs Azimuth Accuracy setting
(95% of DSUGPS, 7 satellites)
Line
Working with DSU3-428 & DSUGPS links > DSUGPS firmware upgrading
428XL Users Manual Vol. 1 171
April 11, 2013
5
Figure 5-75 Max convergence time vs Position Accuracy setting
(95% of DSUGPS, 7 satellites)
DSUGPS firmware upgrading
A Download contextual menu is available from the show/hide button
for the DSUGPS links in the instrument view. That menu opens a
Download DSUGPS window that allows loading a new firmware
version to all DSUGPS-428 units present in the spread.
Note that prior to using the procedure below you must go to Field Off,
open the jConfig window, go to Off Line, open the Crew Setup and set
the Time Management (page 90) mode to Internal Clock, then go to
On line, and then Field On.
To load a new firmware version:
1. In the Download DSUGPS dialogue box, click on Select
Download Files.
Line
Working with DSU3-428 & DSUGPS links > DSUGPS firmware upgrading
172 428XL Users Manual Vol. 1
April 11, 2013
5
Figure 5-76
2. Select the SEPASApp_1001.mem file.
Figure 5-77
3. Click on Update DSU3-GPS.
4. In the confirmation box that shows up, click Yes.
Right-click on
show/hide
button
Line
Working with DSU3-428 & DSUGPS links > DSUGPS firmware upgrading
428XL Users Manual Vol. 1 173
April 11, 2013
5 Figure 5-78
5. In the confirmation box that shows up, click OK. Wait until
downloading is complete (the message End of DSU3-GPS
download function should appear in the message box).
Figure 5-79
6. Close the window.
7. Go to Field Off. In the jConfig window, go to Off Line, open the
Crew Setup and set the Time Management (page 90) mode to
GPS (Novatel Propak), then go to On line. Go to Field On in
the jLine window.
Line
Working with DSU3-428 & DSUGPS links > DSU Form Line function
174 428XL Users Manual Vol. 1
April 11, 2013
5
DSU Form Line function
As usual, the Form Line function is applied to the number of channels
you specify in the Channels to Form field. This must be a multiple
of 3 if you apply Form Line to a DSU line segment.
DSU Sensor view
Figure 5-80
Line
Working with DSU3-428 & DSUGPS links > DSU Instrument view
428XL Users Manual Vol. 1 175
April 11, 2013
5
DSU Instrument view
DSU3-428
Figure 5-81 DSU3-428
DSUGPS
Figure 5-82 DSUGPS
When using DSUGPS links, a reference GPS (Novatel Propak) receiver
is attached to the LCI. The 10-MHz oscillator signal from that GPS
receiver is used to lock the clock of the LCI to the GPS time. After
power-on, the recording truck (LCI) is displayed in red until the LCI
clock is locked to the GPS clock (this should take less than a quarter of
an hour).
DSU3-428
DSUGPS
Popup menu used
to turn on/off GPS
and load firmware
to DSUGPS
Red until
LCI clock is
locked to GPS
Line
Working with DSU3-428 & DSUGPS links > DSU Instrument view
176 428XL Users Manual Vol. 1
April 11, 2013
5
Once the DSUGPS units are visible, they are displayed in yellow for at
least 20 seconds, then in green if they achieve the required positioning
accuracy (i. e. convergence is complete, which normally takes less than
24hours). The colour of the antenna in the DSUGPS icon may be:
Grey: if GPS is Off and the position is not determined.
Blue (briefly): on a request for turning GPS on, or if waiting for a
reply.
Red: if GPS is on, but the first convergence calculation is not done or
the process is in one of the following situations:
- tracking too few satellites (less than two) after the first
calculation;
- or Carrier/Noise ratio (CNo) <20 dB;
- or second GPS antenna not working (Bad antenna status is
true in the Numeric view).
Yellow: if GPS is On, and the position observations are transmitted to
the server so that it can perform the convergence calculation (at least
every 30minutes). The following three conditions must be met:
- Tracking two or more satellites,
- CNo >20 dB;
- Both GPS antennas OK.
Green: if the position is determined with the required accuracy, and
GPS is off (position observations are no longer recorded).
The values or statuses of the data used to control the colour attribute are
visible in the DSU Numeric view (page 177). Naturally, whenever a
DSUGPS is moved to another place in the spread, the new position
needs to be determined. The colour of the icon is updated accordingly,
if located in the active spread, or if a Superspread is used.
Note that the DSUGPS receiver point positions are recorded in SPS files
available from the Log window. See DSUGPS receiver point positions
(page 586).
Line
Working with DSU3-428 & DSUGPS links > DSU Numeric view
428XL Users Manual Vol. 1 177
April 11, 2013
5
DSU Numeric view
Figure 5-83
The numeric view has the following specific columns for a DSUGPS:
Ch Nb: channel number 1 (V) or 2 (I) or 3 (C).
Receiver Serial Nb: serial number of the GPS card.
Easting, Northing, Elevation, Azimuth: these four columns show
the recorded position, or 0 if the GPS antenna is red (convergence not
achieved, or too few satellites, or CNo<20dB; or second GPS
antenna not working).
EastingStDev, NorthingStDev, ElevationStDev, AzimuthStDev:
standard deviations of observations, used in convergence
calculations. Convergence is achieved if both of the following
conditions are met:
- the position standard deviation is less than 0.75 m, calculated as
the square root of (EastingStDev +NorthingStDev)
- and Azimuth Standard Deviation is below the threshold
calculated from the Azimuth Accuracy setting in the DSUGPS
Setup menu (page 169).
Avg Number Visible Sats: average number of visible satellites.
Avg Lock Time: The locktime count will max out at 255 seconds for
the SEPAS observation record. If the average it too low (<30) further
investigation might be required to determine the cause for the
continuous loss of lock.
Avg CNo Antenna 1, Avg CNo Antenna 2: Average Carrier/Noise
ratio of each antenna.
Start of Recording, End of Recording: start time and end time of
observation recording.
Line
Working with DSU3-428 & DSUGPS links > DSU Seismonitor
178 428XL Users Manual Vol. 1
April 11, 2013
5
Number of Records: number of recorded observations.
Gps state: colour of the DSUGPS icons antenna in the Instrument
view. See DSU Instrument view (page 175) for a description of the
colour code.
Gps On: true if the GPS cards power supply is on, otherwise
false.
Bad Antenna: status of the second GPS antenna (false if the
antenna is OK, otherwise true).
Coordinates StdDev: square root of
(EastingStDev +NorthingStDev).
SPS Record Duration: length of recording in SPS file.
GPS Recording Duration.
DSU Seismonitor
By default, only the vertical channel is shown.
The Gain slider button, in conjunction with the Sensor Type option
button, allows you to adjust the Seismonitor gain for each type of sensor
(i. e. each channel).
Figure 5-84
You can open a separate view to monitor each Sensor Type. Any
change to the seismonitor gain for a Sensor Type in a window is
replicated in the other windows.
Used to choose which channel
to adjust with the Gain slider
button
Line
Working with DSU3-428 & DSUGPS links > DSU3 tilt correction
428XL Users Manual Vol. 1 179
April 11, 2013
5
DSU3 tilt correction
In the Install window, you can choose to enable or disable correction of
DSU3 traces with the tilt angle recorded during tilt tests. See
Instruments On Field (page 68).
If you choose to enable tilt correction, the correction to each trace is
done using the formula given in Users Manual Vol. 3 (Reference
Information).
If tilt correction is enabled and a DSU3 does not have any tilt test result
available, then the correction is not done on its channels and a warning
message is displayed.
If any square root cannot be calculated because the value involved is
negative, the correction is not done and a message is displayed.
Line
Working with ULS field equipment > Overview
180 428XL Users Manual Vol. 1
April 11, 2013
5
Working with ULS field equipment
In this section:
Overview(page 180)
Deployment (page 181)
Survey setup (page 183)
Marker setup (page 184)
Detour setup (page 189)
Auxiliary channel setup (page 197)
Test setup (page 197)
Checkline (page 197)
Overview
To work with submersible field electronics (FDU2S), you must enable
that option in the Install window.
ULS line units (FDU2S and LAULS) are reversible, meaning that their
line connectors are used indiscriminately as Low or High ports. ULS
cables, whether with mono-sensor or dual-sensor takeouts, are
reversible too.
FDU2S channels are tantamount to FDU channels, except for Sensor
tests (a Sensor Distortion test is available for FDU2S channels).
Note: Unused channels at standard/ULS junctions are automatically
skipped by the system (they do not need to be entered into the
Detour setup). They are not tested in Instrument tests.
Note: The FDU2S does not support a Point Code with cs (skipped
channel) as Sensor Type.
Line
Working with ULS field equipment > Deployment
428XL Users Manual Vol. 1 181
April 11, 2013
5
Deployment
You can insert a submersible segment anywhere in a standard 428XL
telemetry line, using a ULS Adapter (P/N 1P41081653) at either end,
but the following two rules apply at all times:
1. If a line ends with a ULS segment, it must end with an FDU2S
unit so that the outermost receiver point (103 in the example
below) can be acquired.
Figure 5-85
With mono-sensor takeouts, the last channel must be muted if it is
unused, or else errors will appear in the Sensor view. In the
example below, by default the system creates a dummy channel
104 that must be muted.
Figure 5-86
102 103
103 104
102 103 101
101
Unused channel
Unused channel
End
of Line
(cap P/N 512210065)
End
of Line
(cap P/N 512210065)
End
of Line
(cap P/N 512210065)
FDU2S
FDU2S FDU2S
FDU2S
FDU2S
FDU2S
Unused channel
FDU2S
103 102
This channel must
be muted
End
of Line
(cap P/N 512210065)
FDU2S FDU2S
Both channels
are unused
Line
Working with ULS field equipment > Deployment
182 428XL Users Manual Vol. 1
April 11, 2013
5
2. Any FDU2S channel that is connected to a standard 428XL unit
(FDU, LAUX, LAUL) is skipped (not used, not tested in
Instrument tests).
Figure 5-87
Figure 5-88
159
FDU
161 162 160
This channel is
not used
No. 4204531
FDU2S FDU2S
FDU
55-m jumper (512500210)
or
3-m jumper +ULS adapter
(512500211 +1P41081653)
105 104
This channel is
not used
This channel is
not used
LAUX
No. 4205121
FDU2S FDU2S
FDU2S FDU2S
Line
Working with ULS field equipment > Survey setup
428XL Users Manual Vol. 1 183
April 11, 2013
5
Survey setup
To implement mono-sensor takeouts, define a specific Sensor Type for
FDU2S channels if you need one, then do as usual to define a Point
Code and receiver points. As usual, the traces recorded on tape will be
in the same order as in the Survey setup.
To implement dual-sensor takeouts:
- Define a Sensor Type for each type of sensor (for example s1
for geophones, s2 for hydrophones). It is important to specify
a distinct resistance range for each sensor type, in the
Continuity Min and Max fields, so that the system can
identify the type of sensor connected on each channel by
measuring the resistance across each takeout.
- Define a Point Code using both Sensor Types and the +
operator. For example, you can define p1 as s1+s2. You dont
need to care about the Low/High orientation of the takeouts: the
system will automatically assign the appropriate sensor type to
each channel, depending on the input resistance measured at
power-on. (A Resistance test is automatically launched when
you go to Field On).
Figure 5-89
- Define the Survey (for example 101-150p1, ...). With a
Pi=Sj+Sk point code, the trace which assumes the Sj type is
recorded first, regardless of the Low/High orientation of the
FDU2S units or the takeouts.
Note: If the system is unable to discriminate between the two takeouts
(because they both fall into the same resistance range), then it
still assigns one sensor type to one channel and the other type to
the other channel, but a Resistance test error appears in the
s1
s2
Low
(or High)
High
(or Low)
p1 =s1+s2
FDU2S FDU2S
Line
Working with ULS field equipment > Marker setup
184 428XL Users Manual Vol. 1
April 11, 2013
5
Sensor view. If the default assignment is not acceptable, you
can change it by making the appropriate changes in the Survey
setup.
Note: Because the channel assignment is done when you go to Field
On, any sensors connected subsequently will not have any
channel assigned unless and until you go to Field Off then
Field On again.
Marker setup
You cannot use an LAULS as a Marker, but you can use an FDU2S.
To use an FDU2S as a Marker, you must specify its Serial No. and Line
No. in the Marker setup, as usual, and the receiver Point No. of the
adjacent topographic stake on the LOW or HIGH side of it. You must
also specify which one of its channels is assigned to that topographic
stake, with the following convention:
- The FDU2S port to be used as Low port is regarded as channel
No. 1.
- The FDU2S port to be used as High port is regarded as channel
No. 2.
Figure 5-90
The position of the LAULS is automatically computed by the system:
this will be 101 in the example below (that is the first receiver point
encountered on its Low side, even though the adjacent FDU2S channel
on its low port is assigned to point 102).
LAULS
FDU2S
1 2 1 2 1 2 1 2 1 2
LAULS FDU2S
Line
Working with ULS field equipment > Marker setup
428XL Users Manual Vol. 1 185
April 11, 2013
5
Mono-sensor takeouts
Figure 5-91 (p1 =s1)
Assuming in the example shown in Figure 5-91 you wish to use FDU2S
No. xxxx as a Marker, you must assign Point No. 101 to its channel 1
(or 102 to its channel 2) in the Marker Setup.
Figure 5-92 (p1 =s1)
Assuming you wish to use the LAUXS in Figure 5-92 as a Marker, you
must assign Point No. 101 to it (you must specify the receiver Point No.
of the low-side channel encountered on its Low port).
Figure 5-93 (p1 =s1)
Assuming you wish to use the LAUX in Figure 5-93 as a Marker, you
must assign Point No. 101 to it in the Marker Setup (as usual, you must
specify the adjacent receiver Point No. encountered on the Low side of
the LAUX).
101
LAULS
103 104
No. xxxx
s1
102
s1
ch 1 2 2
s1 s1
ch 1
M
a
r
k
e
r
Low High
FDU2S FDU2S
101 103 104
s1
102
s1
ch 1 2
s1 s1
M
a
r
k
e
r
No. xxxx
LAUXS
Low High FDU2S FDU2S
ch 1 2
101 103
No. xxxx
s1
102
s1 s1
No. zzzz
LAUX
No. yyyy
M
a
r
k
e
r
Low High
FDU2S
FDU2S FDU2S
Line
Working with ULS field equipment > Marker setup
186 428XL Users Manual Vol. 1
April 11, 2013
5
As a result in the Instrument view:
- The Low channel of FDU2S No. xxxx is assigned to the sensor
at Point No. 101. Its High channel is skipped because it is
connected to an LAUX
- The Low channel of FDU2S No. yyyy is skipped. Its High
channel is assigned to the sensor at Point No. 102.
- The Low channel of FDU2S No. zzzz is assigned to 103, its
High channel to 104, etc.
Dual-sensor takeouts
Figure 5-94 (p1 =s1 +s2 or p1 =s2 +s1)
Assuming you wish to use FDU2S No. xxxx in Figure 5-94 as a Marker,
you must assign Point No. 102 to its channel 2 in the Marker Setup
(you cannot choose point 101 and assign it to channel 1).
As a result in the Instrument view:
- The Low channel of FDU2S No. xxxx is assigned to a sensor at
Point No. 101. Its High channel is assigned to a sensor at Point
No. 102.
- The Low channel of FDU2S No. yyyy is assigned to the other
sensor at Point No. 102. Its High channel is assigned to a sensor
at Point No. 103, etc.
101
LAULS
No. xxxx
102
s2
ch 1 2
No. yyyy
s1
s2
s1
103
s2
s1
M
a
r
k
e
r
Low High
FDU2S FDU2S
Line
Working with ULS field equipment > Marker setup
428XL Users Manual Vol. 1 187
April 11, 2013
5
Figure 5-95 (p1 =s1 +s2 or p1 =s2 +s1)
Assuming you wish to use the LAUX in Figure 5-95 as a Marker, you
must assign Point No. 101 to it in the Marker Setup (as usual, you must
specify the receiver Point No. of the adjacent channel encountered on
the Low side of the LAUX).
As result in the Instrument view:
- The Low channel of FDU2S No. xxxx is assigned to a sensor at
Point No. 101. Its High channel is not used.
- The Low channel of FDU2S No. yyyy is not used. Its High
channel is assigned to a sensor at Point No. 102.
- The Low channel of FDU2S No. zzzz is assigned to the other
sensor at Point No. 102. Its High channel is assigned to a sensor
at Point No. 103, etc.
Figure 5-96 (p1 =s1 +s2 or p1 =s2 +s1)
Assuming you wish to use the LAUXS in Figure 5-96 as a Marker, you
must assign Point No. 101 to it in the Marker Setup (you must specify
the receiver Point No. of the low-side channel encountered on its Low
port).
101 103
No. xxxx
102
No. zzzz
LAUX
No. yyyy
s2
s1
s2
s1
s2
s1
M
a
r
k
e
r
Low High FDU2S FDU2S FDU2S
101 103
No. xxxx
102
s2
s1
s2
s1
s2
s1
LAUXS
M
a
r
k
e
r
Low High FDU2S FDU2S
Line
Working with ULS field equipment > Marker setup
188 428XL Users Manual Vol. 1
April 11, 2013
5
Mono/dual sensor transition
Figure 5-97
No marking problem will arise in the example shown in Figure 5-97.
Figure 5-98
In the example shown in Figure 5-98, the system will interrupt the
marking sequence because it cant assign the s1 sensor of receiver
point 103. An error message will appear: Impossible to assign rcv pt
103 to FDU2S xxxx channel: detour needed.
You have to use the Detour setup to skip the Low channel in FDU2S
No. xxxx, by creating a detour with FDU2S No. yyyy channel 2 as Low
Limit and FDU2S No. xxxx channel 2 as High Limit. See Detour setup
on page 189.
p1 =s1
p2 =s1 +s2
101 104
s2
s1 s1
105
s2
s1
102
s1
103
s1
Low High
101-103p1,104-105p2
FDU2S FDU2S FDU2S
p1 =s1
p2 =s1 +s2
ch 1 2
101 103
s2
s1 s1
104
s2
s1
102
s1
No. yyyy No. xxxx
This channel
should be skipped
Low High
101-102p1,103-104p2
FDU2S FDU2S
FDU2S
Line
Working with ULS field equipment > Detour setup
428XL Users Manual Vol. 1 189
April 11, 2013
5
Detour setup
As usual, to describe a detour you must specify the type and serial
Number of the last active unit on the Low side of the detour and first
active unit on the High side in the Detour Setup window. In addition,
with FDU2S units, you have to use the Chan Nb (Channel Number)
field to specify which channel is the last active on the Low side and
which is the first active on the High side. In some cases, the other
channel may be unused.
Figure 5-99
The Channel number to specify in the Chan Nb field is not the
hardware channel number (stored in the memory of the FDU2S).
Instead, use the following convention:
- The FDU2S port on the Low side is regarded as channel No. 1.
- The FDU2S port on the High side is regarded as channel No. 2.
See the examples below.
First active channel
on High side
FDU2S FDU2S
Last active channel
on Low side
Line
Working with ULS field equipment > Detour setup
190 428XL Users Manual Vol. 1
April 11, 2013
5
Detours with Mono-sensor takeout cables
Figure 5-100
In the example shown in Figure 5-100:
- The Low channel (No. 1) of FDU2S No. 4204621 is used as the
last active channel at the Low end of the detour. It is assigned to
the sensor located at Point No. 766. The High channel of this unit
is not used.
- The High channel (No. 2) of FDU2S No. 4204461 is used as the
first active channel at the High end of the detour. It is assigned
to the sensor located at Point No. 767. The Low channel of this
unit is not used.
765
No. 4204621
766
No. 4204461
ch 1 2 ch 1 2
767 768
Detour
FDU2S FDU2S 4204621 1 4204461 2
Low High
Unused
channel
Unused
channel
First active channel
on High side
Last active channel
on Low side
FDU2S
FDU2S
FDU2S
FDU2S
FDU2S
Line
Working with ULS field equipment > Detour setup
428XL Users Manual Vol. 1 191
April 11, 2013
5
Figure 5-101
In the example shown in Figure 5-101:
- The High channel (No. 2) of FDU2S No. 4204621, assigned to
the sensor located at Point No. 767, is used as the last active
channel at the Low end of the detour.
- The High channel (No. 2) of FDU2S No. 4204461, assigned to
the sensor located at Point No. 768, is used as the first active
channel at the High end of the detour. The Low channel of this
unit is not used.
Detour
767
No. 4204621 No. 4204461
ch 1 2
768 769
ch 1 2
Low High
4204461 FDU2S 4204621 FDU2S 2 2
Unused
channel
Both channels
are unused
First active channel
on High side
Last active channel
on Low side
FDU2S
FDU2S
FDU2S
FDU2S FDU2S
Line
Working with ULS field equipment > Detour setup
192 428XL Users Manual Vol. 1
April 11, 2013
5
Figure 5-102
In the example shown in Figure 5-102:
- The High channel (No. 2) of FDU2S No. 4204621, assigned to the
sensor located at Point No. 103, is used the last active channel at the
Low end of the detour.
- The Low channel (No. 1) of FDU2S No. 4204461, assigned to the
sensor located at Point No. 104, is used as the first active channel at the
High end of the detour.
103
No. 4204621 No. 4204461
ch 1 2
104
ch 1 2
Low High
Both channels
are unused
Both channels
are unused
4204461 FDU2S 4204621 FDU2S 2 1
Detour
First active channel
on High side
Last active channel
on Low side
FDU2S FDU2S FDU2S FDU2S
FDU2S
Line
Working with ULS field equipment > Detour setup
428XL Users Manual Vol. 1 193
April 11, 2013
5
Detours with dual-sensor takeout cables
Figure 5-103
In the example shown in Figure 5-103:
- The Low channel (No. 1) of FDU2S No. 4205191, assigned to one of
the sensors located at Point No. 765, is used as the last active channel at
the Low end of the detour. The High channel is not used.
- The High channel (No. 2) of FDU2S No. 4204395, assigned to one of
the sensors located at Point No. 766, is used as the first active channel
at the High end of the detour. The Low channel of this unit is not used.
765
No. 4205191 No. 4204395
ch 1 2 ch 1 2
766 764
Low High
4204395 FDU2S 4205191 FDU2S 1 2
Detour
Unused
channel
Unused
channel
First active channel
on High side
Last active channel
on Low side
FDU2S
FDU2S FDU2S FDU2S FDU2S
Line
Working with ULS field equipment > Detour setup
194 428XL Users Manual Vol. 1
April 11, 2013
5
Snaking layout
Snaking layouts are allowed. In the example shown in Figure 5-104 with
mono-sensor takeouts, you must set a Detour with the Low channel
(No. 1) of FDU2S No. 4204395 (point No. 788) as the last active
channel at the Low end of the detour, and the High channel (No. 2) of
FDU2S No. 4204431 (point No. 788) as the first active channel at the
High end of the detour. Also you must activate the Stop Marking
option.
In the Marker setup, you have to set a marker on Line 70, for example
assign point No. 786 to the Low channel (No. 1) of FDU2S
No. 4204478, and activate the Reversed option for that marker. (Do
not set the marker on the unit used as detour limit).
Figure 5-104
785
No. 4204431
786
ch 1 2
787 788
Low High
High channel
unused
No. 4204395
ch 1 2
4204395 FDU2S 4204431 FDU2S 1 2
60
70
FDU2S 4204478 70 786 1 1
No. 4204478
ch 2 1
First active channel
on High side
Last active channel
on Low side
FDU2S
FDU2S FDU2S
FDU2S FDU2S
Line
Working with ULS field equipment > Detour setup
428XL Users Manual Vol. 1 195
April 11, 2013
5
In the example shown in Figure 5-105 with mono-sensor takeouts, you
must set a Detour with the Low channel (No. 1) of FDU2S No. 4204431
(point No. 788) as the last active channel at the Low end of the detour,
and the Low channel (No. 1) of FDU2S No. 4204395 (point No. 788) as
the first active channel at the High end of the detour. Also you must
activate the Stop Marking option.
In the Marker setup, you have to set a marker on Line 70, for example
assign the Low channel (No. 1) of FDU2S No. 4204395 to point
No. 788, and activate the Reversed option for that marker.
Figure 5-105
785
No. 4204395
786
ch 1 2
787 788
Low High
High channel
unused
60
70
No. 4204431
ch 1 2
4204395 FDU2S 4204431 FDU2S 1 1
First active channel
on High side
Last active channel
on Low side
FDU2S 4204395 70 788 1 1
High channel
unused
FDU2S FDU2S
FDU2S FDU2S
FDU2S
FDU2S
Line
Working with ULS field equipment > Detour setup
196 428XL Users Manual Vol. 1
April 11, 2013
5
In the example shown in Figure 5-106 with dual-sensor takeouts, you
must set a Detour with the Low channel (No. 1) of FDU2S No. 4204461
(point No. 761) as the last active channel at the Low end of the detour,
and the Low channel (No. 1) of FDU2S No. 4205191 (point No. 761) as
as the first active channel at the High end of the detour. Also you must
activate the Stop Marking option.
In the Marker setup, you have to set a marker on Line 70, for example
assign the Low channel (No. 1) of FDU2S No. 4204881 to point No.
761, and activate the Reversed option for that marker.
Figure 5-106
No. 4205191
760
ch 1 2
761
Low High
High channel
unused
60
70
No. 4204461
ch 1 2
4205191 FDU2S 4204461 FDU2S 1 1
First active channel
on High side
Last active channel
on Low side
FDU2S 4204881 70 761 1 1
High channel
unused
ch 2 1
No. 4204881
FDU2S
FDU2S
FDU2S FDU2S
FDU2S FDU2S
Line
Working with ULS field equipment > Auxiliary channel setup
428XL Users Manual Vol. 1 197
April 11, 2013
5
Auxiliary channel setup
FDU2S channels cannot be used as auxiliary channels.
Test setup
Selecting the FDU2S option in the Install window causes a Sensor
Distortion test to be available in addition to usual tests. It is only
applicable to FDU2S channels.
Unused (skipped) channels at the end of a line or at the standard/ULS
transition are not tested in Instrument tests.
Checkline
The Checkline function is unable to separate the channels of an FDU2S.
Line
Radio telemetry > Radio telemetry equipment
198 428XL Users Manual Vol. 1
April 11, 2013
5
Radio telemetry
In this section:
Radio telemetry equipment (page 198)
Instrument Topographic view (page 199)
The Radio QC Limit setup (page 200)
Frequency management (page 201)
LRU parameters (page 208)
LAUR parameters (page 213)
Wakeup/Sleep (page 213)
Loop test (page 214)
Radio telemetry equipment
The 428XL radio telemetry equipment includes a data acquisition unit
(LAUR-428) and a transceiver unit (LRU).
The LRU (Line Remote Unit) is used as a long range point-to-point
radio relay, or as master transceiver in a radio cell. It can be inserted
anywhere in a spread as an element of the 428XL network to relay the
data transmission on a Line. It connects to any type of 428XL field
electronics (LAUX, LAUL, FDU Link, etc.), except for 100 MHz
Ethernet ports. Built in the LRU is a full performance LAUX.
Line
Radio telemetry > Instrument Topographic view
428XL Users Manual Vol. 1 199
April 11, 2013
5
Instrument Topographic view
Figure 5-107 Radio instrument view
Any message that is affected by RF communications problems is
transmitted again until it is received properly. The colour of each radio
path (green/orange/red) is determined by the LRU, depending on the
rate of retries for messages from the LAUR, so that you can instantly
see if any radio link is in trouble.
In addition, you can zoom in on an LAUR until its antenna is visible.
The antenna is displayed in green, or orange or red, depending on the
RF power margin of the LAUR and on your alert settings, adjustable
using The Radio QC Limit setup (page 200). See Figure 5-109 (page 200).
You can view detailed information on each LRU, LAUR or radio path
by right-clicking on it and choosing Properties from the contextual
menu that pops up.
Figure 5-108 Popup menu
LAUR
(Slave)
LRU
(Master)
Show/hide
radio path
LRU
LAUR
Right-click on
radio path
Right-click on
LRU
Line
Radio telemetry > The Radio QC Limit setup
200 428XL Users Manual Vol. 1
April 11, 2013
5
The contextual popup menu also prompts the available shortcuts, like
Set Wireless (see LRU parameters on page 208) or Enable/Disable
Radio (see Wakeup/Sleep on page 213).
The Radio QC Limit setup
Choose Radio QC Limit from the Setup menu. This opens a setup
window with two scale boxes that allow you to set two alert thresholds
for monitoring the RF power margin in all the LAURs deployed.
The RF power margin (typically at least 27 dB in 428XL radio links) is
calculated as the amount of RF power above the minimum required to
maintain a safe link. It is affected by the link length, terrain
characteristics, atmospheric conditions, local jammers (electric motors,
etc.).
Figure 5-109 Radio QC limit setup
The antenna of each LAUR is displayed in:
green so long as its RF power margin remains higher than your
Orange alert setting;
orange if its RF power margin lies between your Orange and Red
alert settings;
red if its RF power margin drops below your Red alert setting.
LAUR antenna colour
tells you if radio link is
safe
Orange alert
setting
Red alert setting
Line
Radio telemetry > Frequency management
428XL Users Manual Vol. 1 201
April 11, 2013
5
Frequency management
Half-duplex protocol
In the LRU transmission protocol (Half-duplex), time is shared between
transmission of Master-to-Slave messages and transmission of Slave-
to-Master messages.
Master-to-Slave messages are called Network Control Sequences
(NCS), used for synchronization, zero-time transmission and control.
Slave-to-Master messages are called Data Transfer Sequences (DTS),
used for data retrieval, seismonitor and collecting test results.
Figure 5-110
Typically, NCS messages are transmitted every 50 ms. In reply to an
NCS message, the LAUR transmits a DTS message (1.5 to 40 ms long).
The LAUR does not transmit its DTS until and unless its clock is locked
onto that of the LRU.
Figure 5-111 Radio Relay
NCS DTS NCS DTS
(50 ms) (50 ms)
time
Radio frame
LRU LRU
DTS
NCS
(Master) (Slave)
Line or
Transverse to
recording
truck
Line or
Transverse
Line
Radio telemetry > Frequency management
202 428XL Users Manual Vol. 1
April 11, 2013
5
Figure 5-112 Radio Line segment cell
Different setups can be implemented, depending on the required data
rate and on the expected transmission range. See 428XL Installation
Manual for details.
Frequency channels
The RF transceiver in the LRU or LAUR uses a single 2-MHz band for
both transmission and reception. That band is selected between 216
MHz and 249 MHz using the Center Frequency parameter.
Within the 2-MHz bandwidth, you can choose which channel(s) to use
for NCS and DTS messages, by specifying:
a Control Channel Frequency for NCS messages,
one or more Data Channel Frequencies for DTS messages (one for
a radio relay, up to eight for a radio cell).
The necessary bandwidth (0.2 to 0.8 MHz) for a Data Channel depends
on the expected Data Rate (256, 512, 1024 or 2048 kbps). See Figure 5-
113 (page 204).
Note: Because the LRU or LAUR uses a half-duplex protocol, you
can choose the same frequency for the Control Channel and
the Data Channel.
LRU
(Master)
(Slave)
LAUR
DTS
NCS
Line or
Transverse to
recording
truck
Line
(30 channels max.)
Line
(30 channels max.)
LAUR
(Slave)
Line
Radio telemetry > Frequency management
428XL Users Manual Vol. 1 203
April 11, 2013
5
The LAUR must have the same frequency and data rate settings as the
associated master LRU.
IMPORTANT
The two LRU units making up a radio relay should have the same
frequency and data rate settings, and the same Cell Number. Each
LAUR should have the same Cell Number and Center Frequency as
its master LRU.
Note: The available frequency band depends on the regional settings
chosen by the user when installing software on the 428XL GUI
and on the FDPA428 terminal. For compliance with Canadian
and US communications regulations, the frequency band is
limited to respectively:
Canada: 217 to 218 MHz and 219 to 220MHz.
USA: 217 to 220 MHz (and 216 to 217 MHz by licence prior to
J anuary 01, 2002).
Line
Radio telemetry > Frequency management
204 428XL Users Manual Vol. 1
April 11, 2013
5
Figure 5-113 LRU Relay data channels
Center F.
+1 MHz
Center F.
-1 MHz
DTS
1024 k
Center F.
+1 MHz
Center F.
-1 MHz
DTS
2048 k
Center F.
+1 MHz
Center F.
-1 MHz
DTS
256 k
Center F.
+1 MHz
Center F.
-1 MHz
DTS
512 k
Center F.
+1 MHz
Center F.
-1 MHz
NCS
0.2 MHz
+0.8 +0.6 +0.4 +0.2 - 0.8 - 0.4 - 0.6 - 0.2
+0.8 +0.6 +0.4 - 0.8 - 0.4 - 0.6 - 0.2
+0.8 +0.6 +0.4 +0.2 - 0.8 - 0.4 - 0.6 - 0.2
+0.8 +0.6 +0.4 +0.2 - 0.8 - 0.4 - 0.6 - 0.2
+0.8 +0.6 +0.4 +0.2 - 0.8 - 0.4 - 0.6 - 0.2
Default channel
Available channels
Data Channel Freq. #1
Data Channel Freq. #1 Data Channel Freq. #2
Data Channel Freq. #1
Data Channel Freq. #1 Data Channel Freq. #2
Control Freq.
Center
Freq.
Line
Radio telemetry > Frequency management
428XL Users Manual Vol. 1 205
April 11, 2013
5
Figure 5-114 LAUR data channels
Desensitization
Note that the maximum covered range may be shorter on desensitized
channels (i. e. channels on which the strength of the received signal is
normally decreased by the presence of spurious signals from the 8-MHz
and 33-MHz master oscillators in the LRU). In the table below are the
channels that may be affected by desentization, depending on the
selected Data Rate.
Available channels
Center F.
+1 MHz
Center F.
-1 MHz
DTS
Data Channel Freq. #1
1024 k (DQPSK)
Center F.
+1 MHz
Center F.
-1 MHz
DTS
256 k (QPSK)
Data Channel Freq. #1
Center
Freq.
Center F.
+1 MHz
Center F.
-1 MHz
NCS
Control Freq.
0.2 MHz
+0.8 +0.6 +0.4 +0.2 - 0.8 - 0.4 - 0.6 - 0.2
+0.8 +0.6 +0.4 - 0.8 - 0.4 - 0.6 - 0.2
+0.8 +0.6 +0.4 +0.2 - 0.8 - 0.4 - 0.6 - 0.2
Default channel
Line
Radio telemetry > Frequency management
206 428XL Users Manual Vol. 1
April 11, 2013
5
TDM (Time Division Multiplex)
The Time Division Multiplex technique allows several LRU relay cells
to use the same bandwidth without any conflict, by assigning distinct
Subframes (i. e. time slots) to adjacent cells transmitting in that
bandwidth.
Table 5-2
Centre Freq.
(MHz)
Data Rate
(kb/s)
Desensitization
affects on channels
221.184
256 & 512 NCS & DTS 221.2
1024 & 2048 DTS
221.0
221.1
221.2
221.3
221.4
229.376
256 & 512 NCS & DTS 229.4
1024 & 2048 DTS
229.2
229.3
229.4
229.5
229.6
233.309
256 & 512 NCS & DTS 233.3
1024 & 2048 DTS
233.1
233.2
233.3
233.4
233.5
237.568
256 & 512 NCS & DTS 237.6
1024 & 2048 DTS
237.4
237.5
237.6
237.7
237.8
245.760
256 & 512 NCS & DTS 245.7
245.8
1024 & 2048 DTS
245.6
245.7
245.8
245.9
246.0
Line
Radio telemetry > Frequency management
428XL Users Manual Vol. 1 207
April 11, 2013
5
The TDM technique is especially helpful in situations where
neighbouring relay cells are likely to impinge on one another, as is the
case:
where two series-connected relay cells use the same antenna mast,
where too few frequency channels are available.
Where the TDM technique is implemented, each relay cell uses a
dedicated Subframe (i. e. one radio frame out of two or four) instead
of using every radio frame.
Figure 5-115
As a result the Data rate is divided by the Number of subframes.
LRU
LRU
NCS DTS
(50 ms) (50 ms)
NCS DTS
(50 ms) (50 ms)
LRU
LRU
NCS DTS NCS DTS
NCS 1
2
Relay cell 1 2 Relay cell
(transmits on Subframe No. 1) (transmits on Subframe No. 2)
Number of subframes =2
Subframe No. 1 Subframe No. 2 Subframe No. 1 Subframe No. 2
Line
Radio telemetry > LRU parameters
208 428XL Users Manual Vol. 1
April 11, 2013
5
LRU parameters
LRU parameters are available by choosing Set Wireless from the menu
that pops up when you right-click on an LRU in an Instrument view.
An LRU can be set up to be in either Relay mode or Cell mode (Figure 5-
116). In Relay mode, the LRU is either a Master unit communicating to
an LRU Slave unit, or a Slave unit communicating to an LRU Master
unit. No other radio units are allowed. In Cell mode, the LRU is a
Master unit communicating to a cell of LAURs.
Figure 5-116 LRU standard parameters
In either Relay or Cell mode, the User option in the Advanced
Parameters tab allows the user to modify additional parameters. The
Default option displays these parameters, but does not allow the user
to change them (see Figure 5-117).
Click Go (or Apply) to permanently save the RF parameters into non-
volatile memory (flash). This also saves the RF parameters in all
LAURs currently linked in this radio cell.
See the description of each parameter below. See also Radio telemetry
equipment (page 198).
Cell Number
(Allowable range 1 to 31). You must enter a distinct Cell Number for
each LRU radio relay or cell in the 428XL network so that it can be
identified by the 428XL GUI. That is, the two LRUs (Master and Slave)
in a radio relay must have the same Cell Number that is different from
any other Cell Number used in the 428XL network. Likewise, all radio
Line
Radio telemetry > LRU parameters
428XL Users Manual Vol. 1 209
April 11, 2013
5
units in a radio cell (LRU Master and LAURs) must have the same Cell
Number, but that Cell Number must be different from any other Cell
Number used in the 428XL network.
Center Frequency
(Allowable range 216.0 to 249.0 MHz, in 0.1-MHz steps). Center
frequency of the 2-MHz band within which to choose the transmission
channels for the radio relay or cell, depending on the frequencies used
by other radio relays or cells and on the desired data rate. See Figure 5-
113 page 204.
Data Rate
(Available options: 256, 512, 1024, 2048 kbps for Radio Relay, 256
kbps for Radio Cell).
For a radio relay, the 512 and 2048 options require two data
transmission channels. See Figure 5-113 page 204.
For a radio cell, the 256 kbps option requires up to 8 data
transmission channels. See Figure 5-114 page 205.
Line
Radio telemetry > LRU parameters
210 428XL Users Manual Vol. 1
April 11, 2013
5
Figure 5-117 Cell Mode Frequency Display
Transmit Power
(Available options: Standard, Low; defaults to Standard).
Low: Transmit power is 1 mW (0 dBm) for all radio units in this cell.
This option is helpful for tests over a short range.
Standard: Transmit power is 6 W (38 dBm) for all radio units in this
cell. For standard RF transmission conditions.
Number of Subframes
Available options: 1 or 2. See TDM (Time Division Multiplex) (page 206).
Subframe Number
Available options: 1 to the value specified for the Number of
Subframes. See TDM (Time Division Multiplex) (page 206).
Line
Radio telemetry > LRU parameters
428XL Users Manual Vol. 1 211
April 11, 2013
5
CAUTION
Where two or more LRU cells are deployed, changing the Number of
Radio Subframes and Subframe Number parameters in the Line
main window is likely to result in conflicting situations in the relay
cells. Use the FDPA428 instead.
Control Channel (Relay Mode Only)
(Adjustable from Center Freq 0.8 to Center Freq +0.8 MHz in 0.2-
MHz steps; defaults to Center Freq). Center frequency of the 0.2-MHz
channel is used to transmit network control messages (NCS).
Example: if Center Freq =218 MHz, the list of available Control
frequencies are 217.2, 217.4, 217.6, 217.8, 218.0, 218.2, 218.4, 218.6,
218.8 MHz. See Figure 5-113 page 204.
Data Channel #1 Frequency (Relay Mode Only)
Center frequency of the 0.2-MHz channel is used to transmit data
retrieval messages (DTS) (Table 5-3). See Figure 5-113 page 204.
Data Channel #2 Frequency (Relay Mode only)
Center frequency of the second 0.2-MHz channel is used to transmit
data retrieval messages (DTS), depending on the selected data rate
(Table 5-4). See Figure 5-113 page 204.
Table 5-3 Data Channel #1 Frequency
Data Rate 256 512 1024 2048
Data
Channel #1
Freq
From
Center Freq 0.8
to Center Freq +0.8
in 0.2 MHz steps
From
Center Freq 0.8
to Center Freq +0.8
in 0.2 MHz steps
From
Center Freq 0.5
to Center Freq +0.5
in 0.2 MHz steps
From
Center Freq 0.5
to Center Freq +0.5
in 0.2 MHz steps
Default Center Freq Center Freq Center Freq
+0.1 MHz
Center Freq
0.3 MHz
Line
Radio telemetry > LRU parameters
212 428XL Users Manual Vol. 1
April 11, 2013
5
Where Data Channel #2 Freq is required, the system checks that the
difference between Data Channel #1 Freq and Data Channel #2 Freq is
at least 0.2 MHz at 512 kbits/s and 0.8 MHz at 2048 kbits/s.
Note: The available frequency band depends on the regional settings
chosen by the user when installing software on the 428XL GUI
and on the FDPA428 terminal. For compliance with Canadian
and U.S. communications regulations, the frequency band is
limited to
Canada: 217 to 218 MHz and 219 to 220 MHz
USA: 217 to 220 MHz (and 216 to 217 MHz by licence prior to
J anuary 01, 2002).
Control Channel (Cell Mode Only)
Selection that specifies which one frequency is to be used as the control
frequency (NCS). This frequency is used to send messages from the
LRU to the LAURs. See Figure 5-114 page 205.
Data Channel (Cell Mode Only)
Selection(s) that specify which frequencies (maximum of eight) are to
be used to transmit data retrieval messages (DTS) from LAURs back to
the LRU.
Table 5-4 Data Channel #2 Frequency
Data Rate 256 512 1024 2048
Data
Channel #2
Freq
Not required From Center Freq 0.8
to Center Freq +0.8 in
0.2 MHz steps
Not required From Center Freq 0.5
to Center Freq +0.5 in
0.2 MHz steps
Default Center Freq +0.2 MHz Center Freq +0.3 MHz
Line
Radio telemetry > LAUR parameters
428XL Users Manual Vol. 1 213
April 11, 2013
5
LAUR parameters
LAUR parameters (Figure 5-118) are available by choosing Set
Wireless from the menu that pops up when you right-click on an LAUR
in an Instrument view.
See LRU parameters on page 208 for details on these parameters.
Note: An LAUR is a slave of a master LRU that is configured in Cell
mode. The Cell Number and Center Frequency must be the
same as the master LRU.
Figure 5-118 LAUR Parameters menu
Click Go (or Apply) to permanently save the RF parameters into non-
volatile memory (flash). Thus, if the LAUR is powered off and on
again, the latest modifications are recalled.
Wakeup/Sleep
Choosing Disable Radio from the contextual menu that pops up when
you right-click on an LRU, and then going to Field Off, causes the LRU
to go to a power-saving mode called Sleep mode. This allows you to put
a whole radio cell to sleep and then wake it back up again. Note that
when you next go to Field On, a slave LRU will not respond until it has
scanned for new control messages (and there is only one scan cycle per
minute in Sleep mode).
The LRU automatically goes to the Sleep mode if it is left idle for
30minutes.
The Sleep status is not saved to the LRUs non-volatile memory.
Line
Radio telemetry > Loop test
214 428XL Users Manual Vol. 1
April 11, 2013
5
To wake up the radio cell, right-click on the master LRU and choose
Enable Radio from the popup menu.
Right-clicking on an LAUR and choosing Disable Radio from the
popup menu allows you to put this one LAUR to sleep. Likewise, you
can wake it up individually by right-clicking on it and choosing Enable
Radio from the popup menu.
Loop test
LRU Loop test
Right-clicking on an LRU and choosing Start Loop from the popup
menu allows you to check RF communications between that LRU and
any distant LRU (in Relay mode) or LAURs (in Cell mode). So long as
the LRU is busy with the Loop test, it is displayed in red in the
Instrument Topographic view.
LAUR Loop test
Right-clicking on an LAUR and choosing Start Loop from the popup
menu allows you to check RF communications between that LAUR and
the master LRU.
Results
If communications are established with a distant radio unit, the Loop
test returns the attenuation of the signal (in dB) and rate of retries. This
updates those fields in the Numeric view.
IMPORTANT
The Loop test is not possible on a distant radio unit that is in Sleep
mode. To wake up the radio unit see Wakeup/Sleep on page 213.
You cannot launch a Loop test if the radio unit is busy (e. g. during
acquisition, seismonitor, etc.).
Line
Test functions > Overview
428XL Users Manual Vol. 1 215
April 11, 2013
5
Test functions
In this section:
Overview (page 215)
Instrument tests (page 218)
Sensor tests (page 221)
Seismonitor (page 225)
Overview
You open this window by selecting Test Setup from the Setup menu. It
allows you to create a list of tests to do, choose whether or not to record
the results, and specify which channels to test. For Instrument tests, you
also have to choose the channel gain and record length.
Figure 5-119
Select the desired test (from the Test Type pull-down menu) and
options. Click Add to enter the test into the list box. Click Apply to
activate your changes, then click Go to launch the test.
The results appear in the Numeric and/or Graphic view, whichever is
selected. To interpret the results of a particular test, see the legend at the
foot of the main window (with the appropriate test selected in the
graphic view).
List of tests to be
done in sequence
Click and then choose
from pull-down menu that
pops up
Line
Test functions > Overview
216 428XL Users Manual Vol. 1
April 11, 2013
5
The settings in the Test Setup window are also used for every test you
launch with the Go button in the graphic view.
Note: For a description of the principle of each test, see 428XL
Users Manual Vol. 3.
Test Type
Click in this field and choose the desired type of test from the option
button that pops up.
Recorded
Choose this option if you wish to record the acquisition to a test file.
Size of the record: 4 bytes per sample. (Data is not compressed).
Table 5-5 List of tests
Test
Sample Rate Gain Filter Type
Instrument Sensor
Noise
User-selected User-selected User-selected
Distortion
Gain&Phase
CMRR
Crosstalk
Pulse
Gravity
Tilt See Vol. 3
See Vol. 3
See Vol. 3 Resistance
User-selected
Noise
Leakage
User-selected Impulse
Distortion
Line
Test functions > Overview
428XL Users Manual Vol. 1 217
April 11, 2013
5
Absolute Spread
The Absolute Spread list box is used to specify the lines and receiver
positions to be tested (e. g. 10: 101-105g1),
IMPORTANT
You have to specify a gain in the Absolute Spread description or else
the syntax would not be correct, but in Instrument tests the gain
actually used (for seismic and auxiliary channels) is the one selected
with the Gain option button in the Test Setup.
Note: With a rectangular spread, there is an easier way of specifying
the lines and receiver positions to be tested: select the desired
units in the graphic view, then choose and start the desired test
with the buttons available in the main window. See To select
one or more elements (page 117).
Note: In Sensor tests, auxiliary channels are not tested (regardless of
whether or not they are included in the spread). In Instrument
tests, auxiliary channels can be tested (you have to specify a list
of aux channels to be tested).
Note: After doing an Instrument test, use the Look function.
Note: If an overscaling arises during the acquisition of the test signal
(in an Instrument or Sensor test), no result is available (N/A)
for that test.
Line
Test functions > Instrument tests
218 428XL Users Manual Vol. 1
April 11, 2013
5
Instrument tests
Figure 5-120 Instrument test setup
Note: For a description of the principle of each test, see 428XL
Users Manual Vol. 3.
Note: After doing an Instrument test, use the Look function.
Auxiliary Descriptor
The Aux Descr text box is used to specify which auxiliary channels to
test (with the same gain as seismic channels). Use the identification
number assigned to each channel in the Auxiliary channels (page 139)
setup, prefixed with the letter a, with a comma as a separator.
Example of description: a1,a2, etc.
The +operator is not allowed. Use a hyphen to specify more quickly a
range of auxiliary channel numbers (e.g. a1-a4 rather than a1,a2,a3,a4).
Gain
This option button allows you to choose the preamplifier gain to be used
for the Instrument tests.
See the gain code table (Table 5-1 on page 147).
a1-a3,a5-a6,a3 11:113-127g1
Line
Test functions > Instrument tests
428XL Users Manual Vol. 1 219
April 11, 2013
5
Record Length
Duration of the acquisition.
Note: For an Instrument Crosstalk test, the minimum length required
is 5s @ 2 ms SR for FDUs, 8 s for DSU3s.
Note: To calculate the number of samples per trace, see Trace Data
block (page 32) in 428XL Users Manual Vol. 2.
Instrument Noise
(Microvolts) During this test, the channel input is shorted via an internal
resistor. Geophones are not connected. The gain, filter type and sample
rate parameters are user-selected.
Instrument Distortion
(dB) During this test, geophones are not connected. The built-in
generator of the FDU is used as input to the channel under test. The
gain, filter type and sample rate parameters are user-selected.
Instrument Crosstalk
(dB) The test includes two sequences: during the first sequence, the test
generator applies a sine wave to the test network in each even FDU. The
ADC converter in each odd FDU measures the resulting voltage across
its own test network. (The test generator in odd FDUs is disabled).
Table 5-6
Sample rate
(ms)
Record length
Minimum (sec.) Maximum
0.25 1
See 428XL Users Manual Vol. 3
(Specifications).
0.5 2
1 3
2 3
4 3
Line
Test functions > Instrument tests
220 428XL Users Manual Vol. 1
April 11, 2013
5
Conversely, during the second test sequence, the test sine wave is fed to
each odd FDU and the resulting voltage is measured across the test
network in each even FDU.
Note: On the plotter, the test sine wave may appear on adjacent
channels (on either side of an LAU). See Users Manual Vol. 3.
A minimum test length is required (5s @ 2 ms SR for FDUs, 8s for
DSU3s).
The gain, filter type and sample rate parameters are user-selected.
Instrument Gain/Phase error
(%) This test returns the maximum error in amplitude and phase.
Geophones are not connected. The built-in generator of the FDU is used
as input to the channel under test. The gain, filter type and sample rate
parameters are user-selected.
Common Mode Rejection
(dB) During this test, geophones are not connected. The built-in
generator of the FDU is used as input to the channel under test. The
gain, filter type and sample rate parameters are user-selected.
Instrument Pulse
This test is used to record the response of the instrument channel to a
pulse (one sample long). Not applicable to a DSU.
Gravity
(For DSU3 channels only). This test makes it possible to qualify the
complete performance of digital sensor units, by measuring the gravity
acceleration (g).
Line
Test functions > Sensor tests
428XL Users Manual Vol. 1 221
April 11, 2013
5
Sensor tests
Figure 5-121
The Test Setup window lets you manually launch a Sensor test on the
receivers that you specify in the Absolute Spread list box.
The fault threshold is adjustable by selecting Survey from the Setup
menu, then choosing Sensor (see page 131).
Note: Sensor tests are run automatically when FDUs have no
acquisition to perform. Whenever Sensor tests are launched
automatically, i. e. whenever you turn on the line power, or
when you click on the Look button, or when neither acquisition
nor seismonitor is underway (field update mode or Auto Look
option), the Sample Rate defaults to 2 ms for Resistance and
Leakage tests.
Note: For a description of the principle of each test, see 428XL
Users Manual Vol. 3.
Resistance
(ohms) This test allows you to see if geophones are connected. The
Sample Rate is user-selected.
Line
Test functions > Sensor tests
222 428XL Users Manual Vol. 1
April 11, 2013
5
Sensor Leakage
(Mohms) This test displays the global leakage resistance between the
input conductors of the receiver link and the earth. The Sample Rate is
user-selected.
Note: If the channel Input is left unconnected (or if the resistance
connected exceeds 9999 ohm), the Sensor Leakage test is
irrelevant. In field update mode, if the Resistance value
exceeds the specified limit, the Leakage test is not performed,
even if it is selected in the Look Properties setup.
Sensor Noise
(microvolts) In this test the noise picked by the geophones is measured
by performing data acquisition with no Firing Order. The Sample Rate
is user-selected.
Tilt
(%) The Tilt test is sensitive to a number of faults relating to the sensors.
The test results will be affected by anomalies on cutoff frequencies,
damping, sensitivity, distortion (sticking, friction, etc.) and tilt
(geophone not properly planted).
Note: In field update mode, if the Resistance value exceeds the
specified limit, the Tilt test is not performed, even if it is
selected in the Look Properties setup.
Tilt Model
The Tilt Model function is used to store a model of the response to a
pulse on geophones, from a number of geophone arrays known to be in
good repair. The model will be used subsequently in Tilt tests. Because
the samples stored are average values, the higher the number of tested
channels, the closer the model to the theoretical impulse response.
Line
Test functions > Sensor tests
428XL Users Manual Vol. 1 223
April 11, 2013
5
If several sensor types are associated with the channels selected for the
Tilt Model test, a model is computed for each sensor type to be used in
further Tilt tests.
In Dual telemetry, separate models are computed for wireline telemetry
and radio telemetry.
For any sensor type that is not associated with the channels selected for
the Tilt Model test, the corresponding saved model is not modified.
Clicking Go connects the channel input to both the built-in generator
and geophones. Then, acquisition is performed and the model is
computed by averaging the responses of all the geophones tested.
Sensor Pulse
This test is used to record the response of the seismic channel to a pulse
(one sample long).
Line
Test functions > Multiple tests
224 428XL Users Manual Vol. 1
April 11, 2013
5
Multiple tests
Rather than launching tests individually, you may want to do a number
of tests in sequence with a single click on Go. You can do that by
creating batches in this setup window.
Figure 5-122
You can create up to 10 test batches, automatically labelled Test 1 to
Test 10 by the system. When you start from scratch, all test batches are
blank. To create a test batch, do the following:
1. Choose a batch name from the Test Setup option button;
2. Choose the first test to do from the Test Type pull-down menu,
choose the desired gain (for an Instrument test), and specify which
channels to test in the Absolute Spread field. Click Add;
3. Likewise, choose the second test to do in sequence, and click
Add, and so on and so forth.
4. If you want to insert a pause between tests, enter the desired
interval (milliseconds) into the Delay Between Tests field;
Line
Test functions > Seismonitor
428XL Users Manual Vol. 1 225
April 11, 2013
5
5. Enter the duration (milliseconds) of the acquisition into the
Record Length field. The record length is the same for each test
in the batch.
6. If you want to record the results from each test, tick the Record
Results option.
Click Apply to save and activate your settings.
If you want to repeat a group of consecutive tests a number of times:
1. Click on the last test in the group to repeat;
2. Choose Control Loop from the Test Type pull-down menu;
3. In the Loop Line Nb field, enter the index number of the first test
to repeat;
4. In the Nb of Loops field, enter the desired number of cycles;
5. Click Add.
The test batches you create in this setup window are not available from
the test option button associated with the Go button in the main window.
Seismonitor
This window allows you to monitor the input signal on the channels you
specify in the Absolute Spread box.
Figure 5-123
10: 100-500g1
20: 100-500g1
30: 100-500g1
40: 100-500g1
Line
The Form Line setup > General
226 428XL Users Manual Vol. 1
April 11, 2013
5
The Form Line setup
In this section:
General (page 226)
Line Troubleshooting (page 227)
Network Management (page 229)
General
You open this window by selecting Form Line from the Setup menu.
Figure 5-124
This window is mainly used for:
Troubleshooting the line, by going step-by-step with line forming;
Managing the network in case of multi-path layout.
The typical way of using Form Line is as follows: create a specific
power on/off command by selecting the desired options as explained
below (see Line Troubleshooting on page 227) and clicking on Add. You
can save it by clicking on Apply. Then select a command in the list box
by clicking on it, and launch it by clicking on Go.
Note: After a set of LAUs is powered on/off and channels are
identified by Form Line, all functions can be performed,
including Sensor and Instrument tests, seismonitor and
acquisition.
List of manual power on/
power off commands
Line
The Form Line setup > Line Troubleshooting
428XL Users Manual Vol. 1 227
April 11, 2013
5
Also note that field update is not done automatically on a segment
powered up by Form Line: click on Look (in the Sensors view) to
collect the field update data.
WARNING
All the information stored in the Form Line menu is used at line power-
up. This may prevent some LAU ports from being powered up.
Typically, clear Form Line menu entries after you are finished with
troubleshooting.
Note: If the Form Line menu is not empty as lines are powered up, the
spread is formed step by step. The propagation of power from
LAU to LAU is slower than in the normal mode even if
referenced LAUs are not connected in the spread (due to the
fact that power-up propagation is controlled by software rather
than hardware). An M appears on the readout of the LCI-428
or LCI-G line controller (standing for Manual mode).
Line Troubleshooting
To investigate a problem on a line segment, you can power down one of
the ports of an adjacent LAUL or LAUX, or power up that port and form
a number of channels (or all) attached to it. Also, you can gradually
power up/down a Transverse. To do that:
1. Use the Serial Number field, and the option button that pops up
as you click in the Box Type field, to specify which unit is
targeted.
2. From the Orientation option button, choose the port you want to
power up or power off.
3. If you want to power up the port, tick the Enable option. If you
want to form all the channels attached to that port, tick the All
option, otherwise specify how many channels you want to form in
the Channels to Form field.
Line
The Form Line setup > Line Troubleshooting
228 428XL Users Manual Vol. 1
April 11, 2013
5
4. Choose the appropriate Speed, depending on which type of
channel is attached to that segment: FDU-428 channels support
both 8 and 16Mbits/s data rates; FDU408 channels support only
the 8Mbits/s option (see Default Line Data Rate on page 90).
5. Click Add, then Go.
Forming all channels
With the All option in the Channels to Form field, the Form Line
function applies the line power to the selected port. All the channels
attached to that port are identified and displayed graphically.
If an LAU is connected at the end of that series of channels, it is
powered up, identified and displayed graphically too. The line power is
not propagated automatically by this LAU; this must be done using the
Form Line function.
This allows you to go step-by-step with line power up.
Forming a number of channels
If you choose to form only a number of channels, then the Form Line
function applies the line power to the line and the requested channels
are identified and displayed graphically.
If an LAU is connected at the end of the series of channels, it is powered
up, but is neither identified nor displayed. In this mode, you cannot
power up LAUs beyond the selected LAU.
Line
The Form Line setup > Network Management
428XL Users Manual Vol. 1 229
April 11, 2013
5
Network Management
In case of multi-path layout, it may be interesting to enable/disable
some paths to control the data path and make it optimum.
To that end, you can use the Form Line menu as described below to
prevent the line or transverse power from being set by some LAUs.
Assuming the configuration below:
Figure 5-125
If the network is powered up without any control in the Form Line
setup, the data path may be that of Figure 5-126 or Figure 5-127
(page 230), depending on how hardware line power is relayed.
LAUX-428 #21
LAUX-428 #11
LAUX #12
LAUX #22
R
i
g
h
t

T
r
a
n
s
v
e
r
s
e
R
i
g
h
t
R
i
g
h
t
R
i
g
h
t
R
i
g
h
t
Line
The Form Line setup > Network Management
230 428XL Users Manual Vol. 1
April 11, 2013
5
Figure 5-126 Data Path 1
Figure 5-127 Data Path 2
In order to enforce the second situation (Data path 2), optimum for data
retrieval, enter a command in the Form Line menu to power off the
Right port of LAUX22 (as a result the LAUX#12 to LAUX#22
secondary transverse is displayed but not used for data transfer).
LAUX-428 #21
LAUX-428 #11
LAUX-428 #12
LAUX-428 #22
LAUX-428 #21
LAUX-428 #11
LAUX-428 #12
LAUX-428 #22
Line
The Synthetic setup >
428XL Users Manual Vol. 1 231
April 11, 2013
5
The Synthetic setup
This setup window allows you to create a virtual spread and use a
synthetic signal as seismic source energy to take virtual shots. For
example, you can take virtual shots on a virtual spread to see if your
setup parameters are consistent.
This window also allows you to do Acceptance tests (in that case, you
must tick the Acceptance Test mode option). See Acceptance tests
(page 263) in 428XL Users Manual Vol. 3.
Figure 5-128
Creating a virtual spread
1. Use the navigation keys to move the focus point to the left/right or
upward/downward, depending on where you would like to insert
an element into your virtual spread.
2. Click on the desired icon at the top to choose which object to add.
Navigating
Focus point
1
Adding objects 3
Selecting an
object to add
2
For acceptance
tests only
Line
The Synthetic setup >
232 428XL Users Manual Vol. 1
April 11, 2013
5
3. Click on the appropriate add button, depending on which port you
wish to connect to. The two buttons that add elements on the Low/
High sides also allow you to choose how many elements you want
to add to the element that has the focus. This is an easy way of
replicating line segments.
Figure 5-129
4. Clicking on any element in your virtual spread causes its
description to appear in the upper right corner.
Figure 5-130
The example in Figure 5-131 shows how to connect a Right
Transverse with four FDU links in just a few clicks.
Add one or more
elements on Low
side
Add on Right
side
Add one or more
elements on High
side
Add on Left side
Line (Low) (High)
T
r
a
n
s
v
e
r
s
e

(
L
e
f
t
)


(
R
i
g
h
t
)
Click to
choose how
many to add
Line
The Synthetic setup >
428XL Users Manual Vol. 1 233
April 11, 2013
5
Figure 5-131 Example
Synthetic file
In order to simulate shots, you have to load a file containing the
necessary samples to generate the test signal. Use the Browse button to
do that.
The synthetic signal file should contain the description of the signals fed
to Seismic and Auxiliary channels. Three cases may arise:
A single synthetic signal is described: the same signal is fed both to
Seismic and Auxiliary Channels.
Two synthetic signals are described: the first one is fed to Seismic
channels and the second is fed to Auxiliary channels (used to simulate
single-source correlation operations).
Three synthetic signals are described: the first one is fed to Seismic
channels, the second to the first Auxiliary channel, and the third to the
other Auxiliary channels (used to simulate dual-source correlation
operations).
See also 428XL Users Manual Vol. 2.
File Syntax
Blank lines and lines beginning with #in the first column are ignored.
Acquisitions are identified with a text line starting with the character
@ (in the first column) followed by a space character and an
Move
focus to
Right
Trans-
verse
Connect an
LAUX
Connect an
FDU link
Add an FDU link Add two FDU links
Line
The Synthetic setup >
234 428XL Users Manual Vol. 1
April 11, 2013
5
acquisition number. If there is no @, the signals described are
common to all acquisitions.
Each synthetic signal described begins with an asterisk (*) in the first
column.
The signal is made up of a succession of samples and described with
5 sample values per line, each line starting with the sequential
number of the first value in the line (0, 5, 10, 15 etc.), for the sake of
better legibility.
Each sample is described in the form of a signed integer between -
8388608 and 8388607. The maximum number of samples is 32000,
allowing descriptions of signals with a maximum length of 32000
times the Sample Rate. If the Acquisition Length exceeds the length
of the described synthetic signal, then, after the last sample, the signal
starts again with the first sample (sequential number 0).
Example With Signals Common To All Acquisitions
#Example of file with 3 signals
* Seismic signal with 20 samples
0 0 1 2 3 4
5 5 6 7 8 9
10 10 11 12 13 14
15 15 16 17 18 19
* AUX1 signal with 20 samples
0 0 1 2 3 4
5 5 6 7 8 9
10 10 11 12 13 14
15 15 16 17 18 19
* AUX2 to AUXN signal with 20 samples (N depending on the spread).
0 0 1 2 3 4
Line
The Synthetic setup >
428XL Users Manual Vol. 1 235
April 11, 2013
5
5 5 6 7 8 9
10 10 11 12 13 14
15 15 16 17 18 19
Example With Different Signals In Two Or More Acquisitions
#Example of synthetic file with different signal in two acquisitions.
@ 1
* Seismic signal with 20 samples
0 0 1 2 3 4
5 5 6 7 8 9
10 10 11 12 13 14
15 15 16 17 18 19
* AUX signal with 20 samples
0 0 1 2 3 4
5 5 6 7 8 9
10 10 11 12 13 14
15 15 16 17 18 19
@ 2
* Seismic signal with 20 samples
0 50 51 52 53 54
5 55 56 57 58 59
10 60 61 62 63 64
15 65 66 67 68 69
* AUX signal with 20 samples
0 50 51 52 53 54
5 55 56 57 58 59
Line
The Synthetic setup >
236 428XL Users Manual Vol. 1
April 11, 2013
5
10 60 61 62 63 64
15 65 66 67 68 69
Line
The Download setup >
428XL Users Manual Vol. 1 237
April 11, 2013
5
The Download setup
Typically, you need to use the Download setup after installing a new
release of 428XL software (and patches if any), to update firmware in
LCI-428 boards or LCI-G and in the remote field electronics
deployed. You also have to use this setup window if you connect any
unit that does not have the required software version and/or patches.
Figure 5-132
Typical Download procedure
Typically, this setup window should be used as follows:
1. Be sure the 428XL LCI controller (LCI-428 or LCI-G) is powered
up and all remote line interfacing units (LAUX-428, LAUL-428,
etc.) to be upgraded are connected to it. (FDUs and DSUs may be
present but they are not involved).
2. Go to On Line in the Config main window and Field Off in the
Line main window.
3. Click on the Show Reference Release button. This opens a result
window showing the latest software release loaded on the server.
Line
The Download setup >
238 428XL Users Manual Vol. 1
April 11, 2013
5
The name of the file containing the latest release and patches
appears after each type of unit in the result window.
Figure 5-133
4. Click on the Show Units Version button to view the current
version of all line interfacing units deployed (i. e. LCI, and field
electronics other than FDUs and DSUs). Check to see if all units
have the required software version, revision and patches.
Figure 5-134
5. If all LCI boards have the required software release and patches
but you still wish to update them, choose the Force LCI
Download option in the Download setup window.
LAUX428 428. 5. x dwnf i l e. hci 428. V5x
LAUL428 428. 5. x dwnf i l e. hci 428. V5x
LAUR 428. 5. x dwnf i l e. hci 428. V5x
Name of the
file to load
Patch No. Product
Version No.
428.5.x
LAUX428 #- - - , ver si on 428. 5. x
LAUR #- - - , ver si on 428. 5. x
Serial number
Current software version
& patch No.
Line
The Download setup >
428XL Users Manual Vol. 1 239
April 11, 2013
5
6. If all field electronics units have the required software release and
patches but you still wish to update them, choose the Force
Download option in the Download setup window.
7. If any LCI or field electronics unit does not have the required
release and/or patches, or you wish to download the release again
anyway, click on the Select Download Files button. This opens a
file selection dialog box that automatically takes you to the
appropriate directory (lcCommon/work). Choose the
dwnfile.hci428.V5x file that was prompted by the Show
Reference Release button at step 3 above.
Figure 5-135
8. Click OK. This causes the name of the selected release file to
appear in the Download setup window. As a result, the Update
LCI and Update Spread buttons are enabled.
Line
The Download setup >
240 428XL Users Manual Vol. 1
April 11, 2013
5
Figure 5-136
9. To update LCI boards, click on the Update LCI button.
10. To update field electronics, do the following:
- From the Box Type option button, choose which type of unit you
want to update, or choose All.
- Either choose the All Boxes option or use the S/N field to specify
the Serial Number of a particular unit you want to update.
- Click on the Update Spread button.
WARNING
Update commands will be rejected if the power supply of the targeted
remote units is below 10.5 V. The power supply must stay above 10 V
until downloading is complete.
After updating LCI firmware, you have to go to Off Line / On Line in
the Config main window to restart operations.
If you do not update LCI firmware, you only have to go to Field On to
resume operations.
Software release
file to download
Line
The Download setup >
428XL Users Manual Vol. 1 241
April 11, 2013
5
Note 1: It is alright if you directly download a patched software version,
rather than downloading the original release first, then downloading the
necessary patches separately.
Note 2: If, instead of the message Download completed, you have the
message:
Er r oneous downl oad ...
WARNI NG: t ur ni ng uni t s of f now may make t hemunusabl e i f not
pr oper l y downl oaded.
Do you want t o r et r y anot her downl oad bef or e uni t s ar e t ur ned of f
( y / n) ?
- If you choose y, then the download procedure is restarted, and
software is downloaded again to those units that are not properly
upgraded. If the above error message (Erroneous download ...)
appears again, then choose n rather than retrying, and click on
the Update LCI button again.
- If you choose n, then the download procedure is aborted.
Check all connections. Go to Off Line then On Line in the
Config main window. Click on the Update LCI button again.
Note 3: A Battery failure error message is generated (logged into the
dwnreport.hci428 report file) if the update process is aborted, that is:
- if the power supply of any targeted unit lies below 10.5 V before
downloading begins,
- or if the power supply of any targeted unit drops below 10 V
during the download process.
Note 4: See also Field electronics (page 156) in 428XL Installation
Manual.
Line
The Download setup >
242 428XL Users Manual Vol. 1
April 11, 2013
5
Adjusting the T0 shift
You can adjust the T0 shift by changing the value of
sgmDELAY_TO_ADVANCE_T0_TIME (default is 50 ms) in the
startupLciT0Delay.txt file contained in the following directory:
/export/home/e-428/lcCommon/work
Then, use the Download Setup to enable the new value in two steps:
1. Select the dwnfile.hci428.V5xx file and update the line as
follows:
- Untick the Force download option;
- Click Update Spread.
2. Reset the LCI (by clicking Off Line then On Line in the jConfig
window).
3. Select the dwnfile.hci428.V5xxStartup file (instead of
dwnfile.hci428.V5xx) and update the LCI as follows:
- Tick the Force LCI download option;
- Click Update LCI.
428XL Users Manual Vol. 1 243
April 11, 2013
Chapter
6 Operation
This chapter includes the following sections:
The Main Window (page 244)
The Process Type setup (page 256)
The Source Point Setup (page 275)
Seismic setup options (page 281)
The Source Type setup (page 289)
The Delay setup (page 295)
The Noise Editing setup (page 297)
The Observers Comment Type Setup (page 304)
How to take shots or sweeps (page 305)
Flip-Flop sweeps (page 321)
Simultaneous sources (page 326)
Slip-sweep (page 334)
SQC Dump mode (page 348)
Micro-seismic (page 371)
Autonomous mode (page 373)
Vibrator Guidance (page 378)
Multi-gun Shallow-water shooting mode (page 381)
Master/Slave operation (page 384)
More About Noise Elimination (page 388)
More About Correlation (page 396)
Operation
The Main Window > General
244 428XL Users Manual Vol. 1
April 11, 2013
6
The Main Window
In this section:
General (page 244)
The Operation Table (page 246)
The Active Source view (page 248)
The Active Acquisition view (page 254)
The Operation Report view (page 255)
General
Figure 6-1 OPERATION client window
The Operation client window takes care of the list of shots, providing
details on those planned, the one in progress, the next to do, and those
done if any. It also provides access to shot controls, lets you view the
Operation table
(planned shots)
Stacked acquisitions
within the selected VP
Shot controls
Click to close
view
Resize by
dragging border
Click to add view
Operation
The Main Window > General
428XL Users Manual Vol. 1 245
April 11, 2013
6
status of the acquisition, and provides information about the progress of
it, i. e. ITB, Transmit Error.
Right-clicking in the empty portion of the shortcut bar and ticking/
unticking the available options allows you to show/hide shortcut
buttons.
Figure 6-2
This button allows you to get different views of a table, referred
to as The Operation Table (page 246), which contains the main
information for the acquisition of the data, and also allows you to select
which Source Point to shoot, if necessary.
The Setup menu allows you to generate the Operation table. Each
source point in the operation table is associated with a Process Type
that determines how the Impulsive or Vibroseismic signal is processed.
In the case of Vibroseismic operations, the Process Type is itself
associated with an Acquisition Type that determines which sweep
signal to generate. If stacking is requested, the stacking fold is visible in
the Active Acquisition view.
In this manual, the abbreviation VP (standing for Vibrator Point) is
understood as a source point, completely defined with the SEGD
parameters appearing in the Operation table (Shot Number, Source
Point Index, Source Point Line, Source Point Nb). It is used
indifferently for Vibroseismic or Impulsive shooting.
For details on how you can arrange the views and toolbars as you would
like them, see the Hands-on guide (page 52).
You can show or hide columns in tables by right-clicking in any column
heading and selecting Customize (see Figure 2-25).
For details on the buttons (Go, Stop, etc.), see The Active Source view
(page 248).
- Tick to show shortcuts
- Untick to hide shortcuts
Operation
The Main Window > The Operation Table
246 428XL Users Manual Vol. 1
April 11, 2013
6
The Operation Table
Figure 6-3 Operation table
The Operation Table contains the main information for the acquisition
of the data and allows you to select which Source Point (VP) to shoot.
Different views of that operation table are available (showing all VPs,
or only those to do, or only those done).
Resize the main window, if required, so that all the desired columns can
be viewed, or use the Customize menu (popping up if you right-click
on any column heading) to remove unnecessary columns.
The source operation table is created using the The Source Point Setup
(page 275). The Source Point Setup itself may be created by importing
an SPS-X file with the Log window and then manually making changes
if required. For a description of the parameters appearing in the
operation table (except the Source Point Index), see The Source Point
Setup (page 275).
The Source Point Index allows you to do a VP several times if
required: the original value is 1 and that value is automatically
incremented by 1 every time the VP is done again.
Right-clicking on a VP to do in the Operation Table causes a menu to
pop up that allows you to choose which source to use to do that shot.
Operation Table
Right-click to
choose source
Done
Ready
To do
Available views
Operation
The Main Window > The Operation Table
428XL Users Manual Vol. 1 247
April 11, 2013
6
Then the system uses your settings in The Source Type setup (page 289)
to automatically determine which next VPs to assign to that source.
The indicators ahead of shot numbers should be interpreted as follows:
If all necessary parameters have been set in all main windows, then
clicking any row in the table causes the following functions to be
performed automatically in succession:
1- Look function.
2- Spread configuration (Line Forming).
3- Seismonitor function.
Indicator Meaning
Shots to do (planned Source Points).
This Source Point has the focus. A Source is assigned to it. The
system is ready to send the Firing Order.
This Source Point has the focus, and acquisition is in progress.
Shot suspended (a number of acquisitions remain to do but the focus
has gone to another Source Point).
Shot done. The data from this Source Point has been logged.
Operation
The Main Window > The Active Source view
248 428XL Users Manual Vol. 1
April 11, 2013
6
The Active Source view
The available sources created with The Source Type setup (page 289)
appear in this view telling you which Source Point is currently assigned
to each source, and allowing you to manually assign another one if
required.
Figure 6-4
The indicators in the leftmost column should be interpreted as follows:
Indicator Meaning
Next shot to do with this source.
Shot to do with this Source. The system is ready to send the Firing
Order.
This Source has the focus, and acquisition is in progress.
Source unused until you manually assign a VP to it (with the popup
menu available by right-clicking on the source or in the list of shots to
do).
VP currently associated with
the source
Ready status received,
blocked until you click to accept
it.
VP to be associated with
blocked Ready status.
Operation
The Main Window > The Active Source view
428XL Users Manual Vol. 1 249
April 11, 2013
6
Ready status management
In the Rdy (Ready) column is a pushbutton for each source that lets
you choose how to handle the Ready status from the blaster controller
or vibrator leader:
With the pushbutton released, an R appears in it when the Ready
status is received. The system does not accept it until you click on the
button.
With the pushbutton depressed, the system automatically accepts the
Ready status as soon as it is received.
The Rdy VP column tells you which VP (Source Point) will be
associated with the blocked Ready status when you click on the
pushbutton, whereas the Shot # column tells you which VP is
currently associated with the source.
Right-clicking in the empty portion of the shortcut bar and ticking the
Ready Mgmt option shows two shortcut buttons: Freeze all Readys
and Unfreeze all Readys.
Figure 6-5
Clicking Freeze all Readys releases all pushbuttons (blocks all
sources).
Clicking Unfreeze all Readys depresses all pushbuttons (accepts all
sources).
Operation
The Main Window > The Active Source view
250 428XL Users Manual Vol. 1
April 11, 2013
6
Right-click popup menu
Right-clicking in any row causes a menu to pop up with the following
commands allowing you to manually enable/disable the source:
Associate VP: opens a dialog box that allows you to specify which
VP (by entering its Shot Number) you want to assign to the source.
This does much the same as the Start Seismonitor with Vib
Source command available by right-clicking in the operation table.
After you manually assign a VP to the source, with either of these
commands, the system uses the Increment or Step parameter from
the Sources setup to automatically determine which next VPs to
assign to the source. The Set Increment command available by right-
clicking in the Step column allows changing the Source Point
Increment or Step directly from this view.
Figure 6-6
Associate SPL & SPN: does much the same as the Associate VP
command, but rather than entering the Shot Number of the VP you
want to assign to the source, you have to enter its SPL (Source Point
Line) and SPN (Source Point Number). Note that this can also be
done by dragging and dropping a fleets icon to a source point in the
jPositioning window.
Disassociate VP: use this command if, for any reason, you no longer
want to use the source, or you want to put it to standby or to manually
assign another VP to it. For example if you are working in Slip-
Sweep mode and one of the sources has a problem, you can use
Disassociate VP to momentarily stop using that source but continue
with the others. As a result, the remaining VPs that were formerly
Popup menu available by
right-clicking in row
Operation
The Main Window > The Active Source view
428XL Users Manual Vol. 1 251
April 11, 2013
6
assigned to the unused source will be omitted (unless you decrease
the Step parameter in the Sources setup).
Clean Ready: used to discard the Ready status blocked and
recorded in the pushbutton, for example if you do not want to do the
VP associated with it (displayed in the Rdy VP column). As a
result, you will have to ask the shooter or vibrator leader to send the
Ready status again.
Set Increment: used to change the Source Point increment step
directly from the Active Source view (the Source Type setup is
updated automatically).
Go pushbutton
Clicking this pushbutton sends the Firing Order. Unless you are using
an Impulsive process type, the selected Automation option (Continuous/
Discontinuous/Manual) determines the way of launching the first or
next acquisition for the Source Point selected in the operation table, (see
page 282).
Stop pushbutton
By clicking on Stop, you stop the progress of the acquisition sequence.
You finish the current operation (acquisition or dump). At this point, in
Impulsive mode, you may dump the data to the record process. In other
modes, you can choose either to continue the sequence or do again the
acquisition or end the sequence, using the three pushbuttons (Go,
Cancel, End respectively) prompted:
by clicking on Go you continue the sequence, i.e. you start over at the
acquisition number highlighted in the acquisition table;
by clicking on Cancel you skip the remaining acquisitions: the data
from the incomplete Source Point is discarded but the shot number
remains highlighted (i.e. selected) in the table. You only need to click
Go to do it again.
Operation
The Main Window > The Active Source view
252 428XL Users Manual Vol. 1
April 11, 2013
6
by clicking on End you record the incomplete Source Point without
the remaining acquisitions. Then clicking Go will start the next
Source Point.
Abort pushbutton
Clicking this pushbutton interrupts the current Source Point after the
current acquisition is complete. This stops the sequence and opens a
dialog box that lets you record the data or cancel the Source Point:
If you click OK, the current acquisition is recorded to the SEGD file.
Then clicking Go will cause the sequence to continue.
If you click Cancel, the current acquisition is NOT recorded. The Go,
Cancel, End buttons are prompted and have the same effect as after
clicking Stop.
The Abort pushbutton is legal while waiting for the Time Break.
T. E. indicator
(Transmit Errors) That indicator may appear in the Active Source view
in the event of transmission incidents on the Lines. Those errors are
automatically recovered by the system (the data is successfully
transmitted again) and the seismic data is no way affected. This is
simply indicative of difficult transmission conditions.
ITB indicator
Figure 6-7 Internal Time Break
(Internal Time Break) This indicator appears if the 428XL fails to
receive the Time Break within the TB Window. An ITB is generated
Operation
The Main Window > The Active Source view
428XL Users Manual Vol. 1 253
April 11, 2013
6
after the Time Break Window following the Firing Order has expired,
with an accuracy of +/- 5ms. See TB Window (page 258).
With a Vibroseismic source, ITB is an abortive error. With an impulsive
source, at the end of the acquisition the GUI asks you if you want to
record the data (click OK) or discard it (click Cancel).
Blaster indicator
In the case of an impulsive-type source with a SHOTPRO, or SGS, or
Boombox, or Macha blaster controller, the Active Source view also
includes a Blaster indicator along with Uphole and TB fields. During
acquisition an ASCII message is received from the blaster box (via the
XDEV adapter on the Auxiliary line) containing the Uphole Time and
Time Break values.
Uphole Time: The time the pulse from the blast is detected uphole,
determined by analysis of the Uphole Geophone signal.
TB: Confirmed Time Break, amount of time that current flow to the
blasting cap was greater than 4 amps. The start of current flow is set
up to start at Time Break in the Shot Pro Encoder.
The Blaster indicator may be:
red: No Fire status code received,
green: All OK status code received,
orange: No Confirmed Time Break or Uphole Time, or any of the
following Warnings:
- Confirmed Time Break received but no Uphole Time.
- Low battery.
- Uphole Geophone resistance not measured or out of tolerance.
- Cap resistance not measured or out of tolerance.
If the message includes position data ($GPGGA message), the Source
Point position is viewed in the POSITIONING client window.
Operation
The Main Window > The Active Acquisition view
254 428XL Users Manual Vol. 1
April 11, 2013
6
The Active Acquisition view
The acquisitions to stack, defined with The Process Type setup
(page 256), appear in this view.
Figure 6-8
The indicator ahead of shot number should be interpreted as follows:
Indicator Meaning
Acquisition to do.
Acquisition in progress.
Acquisition done.
Operation
The Main Window > The Operation Report view
428XL Users Manual Vol. 1 255
April 11, 2013
6
The Operation Report view
The table in the Operation Report view has a row for each shot done.
You can customize the table by right-clicking in any column heading,
selecting Customize and then showing/hiding the desired columns (see
page 57).
Figure 6-9 Operation Report view
Selecting a row (shot) in the table and then right-clicking opens a popup
menu that allows you to add, or change, or delete a comment in the
selected row, using the following commands:
Edit: opens a window (Obs Report comment) with a text box
allowing you to type whatever comment you like (any ASCII
character is allowed except double quotation marks). Clicking Apply
enters the comment into the Comment column on the shot selected
in the table.
From Setup: prompts the comments created in The Observers
Comment Type Setup (page 304). Selecting one of them imports it into
the row selected in the table.
Edit From Setup: prompts the comments created in The Observers
Comment Type Setup (page 304). Selecting one of them opens a
window with a text box allowing you to make whatever changes you
like (this does not change anything in the Setup window). Clicking
Apply enters the comment into the Comment column on the shot
selected in the table.
If you want to change (or delete) a comment, select it and use the Edit
command again to enter the new comment (or blank text). If this is a
preset comment (from the Comment Setup), use Edit From Setup
instead.
Type your
comment here
Operation
The Process Type setup > General
256 428XL Users Manual Vol. 1
April 11, 2013
6
The Process Type setup
In this section:
General (page 256)
Auxiliary traces (page 263)
Impulsive type (page 266)
Impulsive Stack (page 267)
Correlation Before Stack (page 268)
Correlation After Stack (page 270)
Vibroseismic Stack (page 272)
How to Generate a Process Type (page 274)
General
Figure 6-10
Operation
The Process Type setup > General
428XL Users Manual Vol. 1 257
April 11, 2013
6
The Process Type associated with each shot determines which type of
seismic signal to generate (depending on the associated Acquisition
Type) and which type of processing to perform prior to recording the
seismic data acquired.
Standard/Advanced
In each process type setup window, the Advanced option prompts an
extra parameter: Refraction Delay (for Impulsive modes) or Listening
Time (for Vibroseismic modes).
Most of the parameters available for the different Process Types you can
create are described below but only the first three are always required.
Refer to the description of each Process Type to see which parameters
you need to set up. See also Auxiliary traces (page 263) and How to
Generate a Process Type (page 274).
Firing Order
For the 428XL to transmit the Firing Order and receive the Time Break,
you can choose to attach the source controller to an LCI interface or to
an LAUX-428 unit. Use the Box Type option to choose which way to
use.
In the Serial Nb field, enter the Serial Number of the LCI or LAU-428
to use.
If you choose the LCI option, use the Plug option button to choose
which Blaster port to use on the LCI.
Record Length
The time (ms) that the data is recorded. In Impulsive modes, this
duration determines the acquisition length (i. e. the length of time that
the seismic data is recorded into LAU acquisition units).
See also Specifications in 428XL Users Manual Vol. 3.
To calculate the number of samples per trace, see Trace Data block
(page 32) in 428XL Users Manual Vol. 2.
Operation
The Process Type setup > General
258 428XL Users Manual Vol. 1
April 11, 2013
6
Listening Time
The time (ms) that the data is recorded (i. e. Record Length), in
Vibroseismic modes. The acquisition length in Vibroseismic modes is
equal to the sweep length plus the Listening Time. (The acquisition
length is the length of time that the seismic data is recorded into LAU
acquisition units).
To calculate the number of samples per trace, see Trace Data block
(page 32) in 428XL Users Manual Vol. 2.
TB Window
The TB Window is a time interval that starts when the 428XL sends a
Firing Order (FO). During the TB Window the 428XL is waiting for
the TB from the shooting system. If the TB occurs within that interval
then the acquisition starts. If it doesnt, then the 428XL generates an
Internal TB (ITB) and the acquisition starts. In Vibroseismic operations,
ITB is an abortive error. In impulsive mode, at the end of acquisition the
GUI will ask you if you want to dump the data to the record process.
Note In Radio or Dual telemetry, the TB Window field is used to
adjust the delay between the FO and TB in Dynamite
operations, or the delay between Early TB and TB.
Note If you are using an LSI, the delay between the Firing Order and
the predicted Time Break must be entered in the TB Window
field.
Refraction Delay
(Allowable range: 0 to 64000 ms, precision 500 ms). This parameter is
only available if you choose the Advanced option.
The Refraction Delay allows you to insert a delay between the Time
Break received by the 428XL and the beginning of the acquisition.
Using the Refraction Delay, you can shorten the acquisition length, but
this assumes that you know how long it will take for the signal to travel
from the shot point to your spread, or else you may lose data.
Operation
The Process Type setup > General
428XL Users Manual Vol. 1 259
April 11, 2013
6
Acquisition Index
Sequential number of each individual acquisition in process types
where Stacking is requested.
Acquisition Type
This field is used to associate the Process Type description with one of
the types of acquisition (Acquisition Type number 1 to 32) created for
the VE464 in The Acquisition Type setup (page 518) or for the VE432 in
The Acquisition Type setup (page 637). The Acquisition Type
determines the following:
- the type of (Basic) sweep to be generated by each vibrator in the
fleet or fleets to use;
- the pilot signals to be supplied by the vibrator controller;
- automatic Lift and High-Line pickup options for the vibrators.
Note for VE432 or VE464 users: A noise elimination Threshold
Type (modulo 16) is automatically associated with each
Acquisition Type:
Threshold Type 1 <=> Acq Type 1
Threshold Type 2 <=> Acq Type 2
... ...
Threshold Type 16 <=> Acq Type 16
Threshold Type 1 <=> Acq Type 17
... ...
Threshold Type 16 <=> Acq Type 32
Operation
The Process Type setup > General
260 428XL Users Manual Vol. 1
April 11, 2013
6
Output option
The Output button allows you to select different operations on the
processed data. It is used, associated with the Add, Change and Delete
buttons, to build the acquisition table.
None. You have to select it when you don't want to do any operation
on the processed data.
Dump: This allows you to dump the data to the record process and
the plotter after processing the acquisition. The memory is cleared
afterwards. You need at least one Dump at the end of the table.
Xdump: You can use this option if you want to request an extra dump
to the record process and the plotter after processing the acquisition,
although that is not the last acquisition. With this option, the
correlation memory is not cleared. Because it increases memory
usage, Extra Dump should only be used with consideration of the
impact on memory resources.
Correl (correlation) With
This field is used to specify which auxiliary channel is the reference
(Pilot) signal for the correlation of seismic channels (a Pilot is
synchronous with the Time Break signal, and usually very similar to the
fleet's sweep signal). The VE432 generates analog pilots (up to 4). The
VE464 generates digital pilots (each Basic type of sweep can be used
as digital Pilot), and also two analog pilots only intended for other
recording systems than the 428XL.
For example, assuming you are using a VE432 and you have created an
auxiliary channel with Pilot as label in the Line window, enter Pilot
into the Correl With field. This will tell the system where the analog
reference signal is physically connected, for correlating the seismic
channels with that signal. See Label (page 139).
If you are using a VE464 with two or more simultaneous sources (e. g.
in Slip-Sweep mode), do not use any analog pilot.
Operation
The Process Type setup > General
428XL Users Manual Vol. 1 261
April 11, 2013
6
Figure 6-11 Correlation of seismic channels with Analog pilot
For VE464 users only:
- For correlation with a digital pilot, enter the Label name of the
Basic sweep type you want to use as reference signal, created in
The Basic Type setup (page 501).
Figure 6-12 Correlation with Numeric pilot
- If you want to use two sources simultaneously, entering the
generic keyword correlWith or addPilot into the Correl with
field will cause the system to use The Acquisition Type setup
(page 518) to determine which Basic sweep type to use as
Numeric Pilot for each fleet.
Figure 6-13 Two simultaneous sources
Note You cannot use the Numeric Pilot option with a 0.25-ms
Sample Rate.
Pilot FDU 1
Pilot
Using an Aux channel
created in the Line
window
as Reference for
correlation of seismic
channels
basicLinear1 1
Basic sweep type
(VE464)
basicLinear1
1 1
Generic keyword
correlWith
1 2
The system will
automatically select the
Basic sweep type
number associated with
each fleet, specified in
this field.
3 2 3 4
Operation
The Process Type setup > General
262 428XL Users Manual Vol. 1
April 11, 2013
6
Auto Correlation Peak Time
Used to shift the autocorrelation peak (recorded on two auxiliary
traces). Unless a value other than 1 is entered for the Auto Correlation
Peak Time shift, only one half of the correlation wavelet will be
recorded on each of the two auxiliary traces (negative time side of the
peak on one trace and positive time side on the other). Theoretically, the
autocorrelation wavelet is symmetrical with respect to the correlation
peak standing for zero time offset between the correlated signals.
This time shift is applied to the results of cross-correlation and to
similarity tests.
Operation
The Process Type setup > Auxiliary traces
428XL Users Manual Vol. 1 263
April 11, 2013
6
Auxiliary traces
The Auxiliaries pane allows you to describe the auxiliary traces you
want to record.
The Processing field is used to enter the name of the Auxiliary channel
to record and, if you want it to be correlated with another signal, this
field also allows you to describe the correlation operation to do.
For analog auxiliary channels, enter the Label name created in the Line
window. For signals from the VE464, see Example for VE464 Numeric
pilots (page 265).
Figure 6-14 Analog Auxiliary channels
For an auxiliary channel to be correlated with another, use the * operator
(e. g. Aux2*Pilot). The system will automatically use the second
operand as the reference signal for the correlation operation.
Autocorrelation or cross-correlation will cause two auxiliary traces to
be generated (one trace for the positive time side of the correlation peak,
and another trace for the negative time side). To specify which auxiliary
trace is used to record the positive (negative) time side, append a Plus
(Minus) sign to the description of the trace.
The order in the Auxiliaries list box determines how the auxiliary traces
will appear in the SEGD file and on your plotter output. (See Figure 6-
14 above).
2
Auxiliary Trace
Number
Auxiliary channels
and processing
Aux2*Pilot-
ta1 Pilot
ta2 Aux2*Pilot-
ta3 Aux2*Pilot+
3rd Aux Trace in SEGD file
Pilot FDU 1
Pilot FDU 1
Aux2 FDU 2
1st Aux Trace in SEGD file
2nd Aux Trace in SEGD file
Operation
The Process Type setup > Auxiliary traces
264 428XL Users Manual Vol. 1
April 11, 2013
6
With the example shown in Figure 6-14 on page 263, the 1st auxiliary
trace in the SEGD file will record the uncorrelated pilot, the 2nd
auxiliary trace (Aux2*Pilot-) will record the negative time side of the
correlation peak, whereas the 3rd auxiliary trace (Aux2*Pilot+) will
record the positive time side.
Example for a VE432 similarity test
Assuming:
- the reference sweep signal is fed to your 1st auxiliary channel
and labelled Pilot,
- the ground force signal is fed to your 2nd auxiliary channel and
labelled ReturnSweep,
- the sweep signal shifted by radio delays is fed to your 3rd
auxiliary channel and labelled ReturnPilot.
Also assuming you want the following signals on your plotter output
and in your SEGD file:
- positive time side of the Autocorrelation wavelet on the 1st
auxiliary trace,
- uncorrelated pilot on the 2nd auxiliary trace,
- positive time side of the cross-correlation of ReturnSweep with
ReturnPilot on the 3rd auxiliary trace.
Then, you have to use the following description in the Auxiliaries pane:
Figure 6-15 VE432 similarity test Auxiliary traces
ta3
Autocorrelation wavelet
on Aux Trace 1
ReturnSweep*ReturnPilot+
ta1 Pilot*Pilot+
ta2 Pilot
ta3 ReturnSweep*ReturnPilot+
Uncorrelated pilot
on Aux Trace 2 Cross-correlation of
ReturnSweep with
ReturnPilot on Aux Trace 3
Operation
The Process Type setup > Auxiliary traces
428XL Users Manual Vol. 1 265
April 11, 2013
6
Example for VE464 Numeric pilots
To record a Numeric Pilot on an auxiliary trace, enter the Label name
of the Basic sweep type you want to record, created in The Basic Type
setup (page 501).
Figure 6-16 Recording a Numeric pilot on an auxiliary trace
You may want to record the Numeric Pilot which is specified in The
Acquisition Type setup (page 518), for each fleet. To do that, use the
generic keyword correlWith (or addPilot). As a result, the system will
automatically select the signal whose Basic Type number appears in the
Correl with (or Add Pilot) field.
Figure 6-17 Recording the Numeric pilot associated with each fleet
3 Aux2*basicLinear1+
ta1 basicLinear1
ta2 Aux2*basicLinear1-
ta3 Aux2*basicLinear1+
basicLinear1 1
Basic sweep type
(VE464)
Correlation of Aux2 with basicLinear1 on 2nd
basicLinear1 to be recorded on 1st Aux Trace
and 3rd Aux traces
- basicLinear2 to be recorded on 3rd Aux Trace
- Correlation of basicLinear2 with basicLinear1
For Fleet 1:
- basicLinear1 to be recorded on 1st Aux Trace
2 addPilot*correlWith-
ta1 correlWith
ta2 addPilot*correlWith-
ta3 addPilot
For Fleet 2:
- basicLinear3 to be recorded on 1st Aux Trace
- Correlation of basicLinear4 with basicLinear3
- basicLinear4 to be recorded on 3rd Aux Trace
Generic
keyword
1 1 1 2
3 2 3 4
Operation
The Process Type setup > Impulsive type
266 428XL Users Manual Vol. 1
April 11, 2013
6
Impulsive type
This type of process is intended for traditional impulsive-source
operations (e. g. explosive).
Figure 6-18
See also:
Standard/Advanced (page 257)
Firing Order (page 257)
Record Length (page 257)
TB Window (page 258)
Refraction Delay (page 258)
Auxiliary traces (page 263)
How to Generate a Process Type (page 274)
Operation
The Process Type setup > Impulsive Stack
428XL Users Manual Vol. 1 267
April 11, 2013
6
Impulsive Stack
Figure 6-19
This type of process is used to stack impulsive data (from any kind of
impulsive low energy source, e. g. weight drop) before recording it.
The Acquisition pane allows you to create a list of acquisitions to stack.
On each acquisition in your list, use the Output option to choose
whether to record the stacked data (Dump option) or not (None option).
You have to choose at least one Dump on the last acquisition.
If you choose the Raw option, then you record the data unprocessed at
the end of each acquisition (with no stacking). So at the end of the
sequence you will have one record for each individual acquisition and
another one for the result from the stacking process.
Note Because they increase memory usage, the Raw and Xdump
options should only be used with consideration of the impact on
memory resources.
See also:
Standard/Advanced (page 257)
Operation
The Process Type setup > Correlation Before Stack
268 428XL Users Manual Vol. 1
April 11, 2013
6
Firing Order (page 257)
Record Length (page 257)
TB Window (page 258)
Refraction Delay (page 258)
Acquisition Index (page 259)
Output option (page 260)
Auxiliary traces (page 263)
How to Generate a Process Type (page 274)
Correlation Before Stack
Figure 6-20
You use this type of process in Vibroseismic operations. As the wording
of the option suggests, correlation will be performed before stacking.
Operation
The Process Type setup > Correlation Before Stack
428XL Users Manual Vol. 1 269
April 11, 2013
6
The Raw option is used when you want to record each individual
acquisition too. In your SEGD file, you get the stacked correlated data
and also the raw uncorrelated acquisition data.
You need at least one Dump of data for each correlation source at the
end of your table.D can be combined with the two sources, for
example D1 to dump the stacked result of the acquisition correlated
with source 1.
The possible single-source or dual-source combinations are: d1, d2,
d1d2.
Note Because they increase memory usage, the Raw and Xdump
options should only be used with consideration of the impact on
memory resources.
See also:
Standard/Advanced (page 257)
Firing Order (page 257)
Record Length (page 257)
TB Window (page 258)
Auto Correlation Peak Time (page 262)
Listening Time (page 258)
Acquisition Index (page 259)
Acquisition Type (page 259)
Output option (page 260)
Correl (correlation) With (page 260)
Auxiliary traces (page 263)
SQC Dump mode (page 348)
SQC Dump mode with VE432 (page 361)
How to Generate a Process Type (page 274)
Operation
The Process Type setup > Correlation After Stack
270 428XL Users Manual Vol. 1
April 11, 2013
6
Correlation After Stack
Figure 6-21
This is another way to work with a vibrator. The first operation consists
of stacking the data and, at the end of it, performing a correlation on the
stacked data and recording the result.
All parameters are the same as with the Correlation Before Stack option.
You just have one more column in the description table, to specify the
sign to apply to the acquired data. The sign will be applied to the data
and the Pilot.
Note Because they increase memory usage, the Raw and Xdump
options should only be used with consideration of the impact on
memory resources.
See also:
Standard/Advanced (page 257)
Firing Order (page 257)
Operation
The Process Type setup > Correlation After Stack
428XL Users Manual Vol. 1 271
April 11, 2013
6
Record Length (page 257)
TB Window (page 258)
Auto Correlation Peak Time (page 262)
Listening Time (page 258)
Acquisition Index (page 259)
Acquisition Type (page 259)
Output option (page 260)
Correl (correlation) With (page 260)
Auxiliary traces (page 263)
SQC Dump mode (page 348)
SQC Dump mode with VE432 (page 361)
How to Generate a Process Type (page 274)
Operation
The Process Type setup > Vibroseismic Stack
272 428XL Users Manual Vol. 1
April 11, 2013
6
Vibroseismic Stack
Figure 6-22
With this mode of operation you just do a stack of the acquisitions. As
a result you will record uncorrelated data in your SEGD file.
The Acquisition Type is defined, as is the case for all Vibroseismic
operation modes, in the Vibrator main window.
The Stack Sign is used to specify the sign to apply to the acquired data.
If you choose the Raw option, then you record the data unprocessed at
the end of each acquisition (with no stacking). So at the end of the
sequence you will have one record for each individual acquisition and
another one for the result from the stacking process.
Like for all Vibroseismic modes you must request a Dump at the end of
the acquisition sequence.
Note Because they increase memory usage, the Raw and Xdump
options should only be used with consideration of the impact on
memory resources.
Operation
The Process Type setup > Vibroseismic Stack
428XL Users Manual Vol. 1 273
April 11, 2013
6
See also:
Standard/Advanced (page 257)
Firing Order (page 257)
Record Length (page 257)
TB Window (page 258)
Listening Time (page 258)
Acquisition Index (page 259)
Acquisition Type (page 259)
Output option (page 260)
Auxiliary traces (page 263)
How to Generate a Process Type (page 274)
Operation
The Process Type setup > How to Generate a Process Type
274 428XL Users Manual Vol. 1
April 11, 2013
6
How to Generate a Process Type
Select Process Type from the Setup menu.
Use the option button at the top of the Process Type Setup window to
choose the desired type of processing. As a result the relevant
parameters are prompted in the upper pane.
For a process type with multiple acquisitions, build the acquisition table
as follows:
Click in the Acquisition index box and enter the necessary range of
rows for your acquisition table. For example, to create 8 rows in one
click, enter 1-8 into the index box;
Select None from the Output option button,
Figure 6-23
Click Add,
For each acquisition in the list box, select the desired Output option
(Double-click on the desired acquisition number, select the output
option, then click Change).
After entering all the parameters to define your Process Type, you only
need to enter a process type number and label in the list box at the foot
of the window, and click Add then Apply to save the process type.
To view the parameters of any process type, double-click on it in the list
box. Then you can make any changes needed and click Change, or
Add, or Delete, as required. To save your changes, click Apply.
1-8
Operation
The Source Point Setup > Source point parameters
428XL Users Manual Vol. 1 275
April 11, 2013
6
The Source Point Setup
In this section:
Source point parameters (page 275)
To generate a Source Point setup (page 280)
Source point parameters
To open this setup window, select Operation from the Setup menu.
Creating a source point setup consists of generating an operation table
containing the characteristics of the successive Shot Points planned.
You can generate this table automatically by loading SPS files to the
database in the Log main window (see Importing an SPS file
page 583). The window below shows an example of operation table.
You can use the Log main window to save the table to a file.
Figure 6-24
A tab is available for each swath which is Active in the Config
windows Swath setup (page 97). The fields in each tab are
automatically populated as you click on Apply in the Log window when
loading SPS-R, -S, -X files. See Multiswath (page 310).
Shot Id.
Shot Point or Vibrator Point sequential number.
Operation
The Source Point Setup > Source point parameters
276 428XL Users Manual Vol. 1
April 11, 2013
6
Break Point
If you enter Yes in the Break Point column, for any Shot/VP, then
the spread will not be configured automatically for this source point (so
that you can skip it if required).
Source Line
Source Point Line Number, adjustable in steps of 0.1 between Lines L
and L+1. Used jointly with the Source Receiver field to define the
source location, and displayed as Source Point Line in the operation
table.
Source Receiver
Source Point receiver position Number, adjustable in steps of 0.1
between receiver positions RP and RP+1. Used jointly with the Source
Line field to define the source location, and displayed as Source Point
Nb in the operation table.
Figure 6-25
Spread Type
Choose one of the Spread Types defined through the Absolute or
Generic Spread Setup menu, in the Line main window.
With an Absolute spread, you have to specify the complete
acquisition spread to be used for each and every shot. When you are
loading SPS files to the database in the Log main window, you
automatically generate an operation table with the Absolute spread.
L
L+1
RP RP+1 RP+2
Source Line
Source Receiver
Operation
The Source Point Setup > Source point parameters
428XL Users Manual Vol. 1 277
April 11, 2013
6
A Generic spread describes the pattern of active channels. That is
helpful if the programming of the spread is done manually and you
do not want to change the description every time the spread moves.
SFL
Spread First Line: first Line Number in the spread, i. e. the Line Number
of the leftmost line in the spread when looking toward the highest
receiver positions; used along with SFN to specify the origin of the
spread. Note that the lines are arranged as in the list box in the Line
windows Survey setup.
For a generic spread, SFL is entered by the operator.
For an absolute spread, SFL is automatically computed by the
system.
SFN
Spread First receiver position Number: lowest Receiver Position in the
spread; used along with SFL to specify the origin of the spread.
For a generic spread, SFN is entered by the operator.
For an absolute spread, SFN is automatically computed by the
system.
Process Type
Choose one of the Process Types defined through the The Process Type
setup (page 256) menu in the Operation main window. The Process
Type you choose will tell the system which type of seismic signal to
generate and which type of processing to perform prior to recording the
seismic data acquired.
Pattern Nb
This field does not appear unless you choose the Guidance option in the
Operating Mode (page 281) setup window. Different types of vibrator
pattern can be defined in the VE432 or VE464 window, each identified
by a Pattern Number. This field allows you to specify which type of
Operation
The Source Point Setup > Source point parameters
278 428XL Users Manual Vol. 1
April 11, 2013
6
vibrator pattern to use for each VP. (For example, you may wish to use
an in-line pattern for some VPs because there is not enough room for a
square pattern). See The Pattern setup window (page 532).
Comments
May be used to enter a comment for each VP. Such comments are
displayed in the Operation table and recorded in the User Header in the
SEGD file. If the User Header is entered into the list of parameters for
an Observer Report or an SPS text file (using the LOG main window),
then the comments will also be included in the Observer Report or SPS
text file.
Any ASCII character is allowed except double quotation marks ().
Superspread
If you want to use a Superspread (an absolute spread that encompasses
several successive spreads), enter its identification number into this
field. You must have created it in the Line main window (see Absolute
spreads page 146).
Figure 6-26
If you do not want to use a Superspread, leave this field empty.
If you generate your Source Point setup by importing an SPS Relation
file, then, because the SPS format does not have any Superspread field,
the Superspread number defaults to the Spread number (the Spread
number contained in the SPS file is automatically copied to the
Superspread field).
Superspread
Operation
The Source Point Setup > Source point parameters
428XL Users Manual Vol. 1 279
April 11, 2013
6
The advantage of using a Superspread lies in that you save time because
after the Superspread is formed, lines dont need to be formed every
time the active spread moves (unless the Aux descriptor changes).
WARNING
When you are using a Superspread, the Gain code for any given trace
must be the same in all individual spreads making up the Superspread,
and in the Superspread itself (because the acquisition of a trace must be
done with the Gain code specified for that trace in the active individual
spread).
Note If you are using different Process Types for the shots associated
with a superspread, be sure the Aux descriptor is the same in all
of them, or else the spread will need to be formed again every
time a change appears in the Aux descriptor, which takes time.
Note When you are using a Superspread, all the channels included in
the superspread are acquired. The system automatically sorts
them and only records the traces belonging in the active spread,
i. e. that which is actually selected in the Operation table (and
described in the input SPS X file if you are using such a file).
Note If any line is disconnected in the Superspread, an acquisition
error will appear even if the disruption is outside the spread
actually selected.
Note Only the channels from the active spread are viewed by the
Seismonitor function.
Note Channels in the Superspread that do not belong in the active
spread are viewed in brown.
Note If you are using DSUGPS links, it is recommended to use a
Superspread so that the DSUGPS units located outside the
active spread can send their GPS data to the central unit.
Operation
The Source Point Setup > To generate a Source Point setup
280 428XL Users Manual Vol. 1
April 11, 2013
6
To generate a Source Point setup
Select Operation from the Setup menu.
Use - and / and comma as shortcuts, in combination with the
command buttons (Add, Change, Delete, Reverse), to generate your
table in a minimum number of steps (see Working with 428XL windows
page 30).
Shortcut with Add button
In Shot/V.P. Id column:
In all other columns except Comment.
Any changes you make will not take effect until you click the Apply
button.
The Reset button works like an undo command. It restores the table as
it was before you last clicked on Apply.
-
Inserted between two numbers, those become the limits of the modification, i.
e. 1-6 from 1 to 6.
/
No change in cells, or step operator, e. g. 1-6/2 (from 1 to 6 every two, only
cells referring to 1, 3 and 5 will be affected.
,
Only named cells are affected e. g. 1,3,5,7 (cells 1, 3, 5 and 7 will be
affected).
- , will give you a syntax error.
/
no change if alone; allows values to be incremented or decremented if it
follows a number, e. g. 10.00/-0.05 (on each change of row you will do the
subtraction -0.05).
Operation
Seismic setup options > Operating Mode
428XL Users Manual Vol. 1 281
April 11, 2013
6
Seismic setup options
In this section:
Operating Mode (page 281)
Automation (page 282)
Slip-Sweep (page 284)
Dynamic Fleet Grouping (page 286)
Look option (page 287)
Reshot option (page 288)
Operating Mode
Figure 6-27
Operation
Seismic setup options > Automation
282 428XL Users Manual Vol. 1
April 11, 2013
6
To open this setup window, select Options from the Setup menu. Click
on the Operating tab. To enable and save your changes, click Apply.
Mode
Standard: choose this option to work with an Explosive-type source
(dynamite, air gun or any other kind of impulsive energy), or with a
standard Vibroseismic source (single source or flip-flop dual source).
SQC Dump: if you choose this option, the correlated data is not
recorded; it is only sent to the QC processing tool for monitoring.
Only uncorrelated (Raw) data is recorded (but not sent to the QC
processing tool). To record vibrator motion signals on auxiliary
traces, see SQC Dump mode (page 348) or SQC Dump mode with
VE432 (page 361).
Micro-seismic: intended for permanent acquisition from a fixed
spread. See Micro-seismic (page 371) for details.
Shallow: intended for shallow-water operations. See Multi-gun
Shallow-water shooting mode (page 381) for details.
Autonomous: allows simultaneous-source shooting with sweeps
being launched independently (by pressing the Ready button on the
DSD of each fleet leader). See Autonomous mode (page 373) for
details.
Automation
Figure 6-28
To open this setup window, select Options from the Setup menu.Click
on the Operating tab. To enable and save your changes, click Apply.
Operation
Seismic setup options > Automation
428XL Users Manual Vol. 1 283
April 11, 2013
6
With a Vibroseismic source or Stacked Impulsive source, the progress
of the acquisitions depends on which Automation option you choose.
(With an Impulsive source, the automation option is of no effect).
Continuous
You are in automatic mode. That means, if you don't have any problem
during acquisitions, you click Go and you are able to shoot
consecutively the SPs or VPs defined in the Operation Table,
respecting the operator-selected delay between acquisitions and SP/
VPs, without any further action until the next Break Point (if any) is
encountered.
You can click Stop to stop the sequence on completion of the current
operation (acquisition or dump) and click Go to resume the sequence.
Note Whenever a new field unit is laid out, it does not appear in the
Line main windows topographic view until the spread is
formed again. If the spread remains the same for consecutive
shots (VPs) in continuous mode, no spread forming is
performed, so any new unit laid out will not be visible unless
you program a Look between VPs (see Look option on
page 287). If any Sensor tests are selected in the Look setup
menu, they are performed too.
Discontinuous
You will do the entire shot point or VP sequence with the specified
delays between acquisitions, and you have to click Go for the next shot
point or VP.
The delay between VPs is not used.
You can click Stop to stop the sequence on completion of the current
operation (acquisition or dump) and click Go to resume the sequence.
Operation
Seismic setup options > Slip-Sweep
284 428XL Users Manual Vol. 1
April 11, 2013
6
Manual
Each acquisition within each shot point must be started manually, by
clicking the Go pushbutton. The Delays Between Acquisitions and
Between VPs are not used.
Slip-Sweep
Figure 6-29
Disable
The Delay setup (page 295) lets you set the required minimum time
between any two successive acquisitions to stack and the delay between
successive VPs.
Figure 6-30
Note that Slip-Sweep is automatically disabled if the Dynamic Fleet
Grouping mode is enabled. Also note that Slip-Sweep is not allowed if
the Time Management (page 90) option in jConfig is set at Internal
Clock.
Standard Mode
This option enables Slip-Sweep operations (for VE432 or VE464 users
only). After a vibrator fleet has started shaking, the Firing Order for the
next sweep is generated as soon as a vibrator fleet is ready and the Slip
Time specified in The Delay setup (page 295) has expired.
Operation
Seismic setup options > Slip-Sweep
428XL Users Manual Vol. 1 285
April 11, 2013
6
Figure 6-31 Slip-sweep standard mode
Check Min Distance
In Standard Slip-Sweep mode, you may want to let the system check
that, after a fleet has started shaking, no fleet is eligible to shake unless
it is far enough from the fleet currently shaking. The Check Min
Distance option makes it possible to specify how far two fleets should
be apart for them to be allowed to shake simultaneously.
Dynamic Mode
If you choose the Dynamic Slip-Sweep mode, The Delay setup
(page 295) window lets you enter different Slip Time setpoints for
different values of the distance between fleets.
Figure 6-32 Slip-sweep Dynamic mode
After a fleet has started shaking, in order to determine which fleet is
next eligible to shake, the system interpolates between your Slip
Time setpoints and calculates the suitable Slip Time for the distance
between each fleet ready to shake and the fleet currently shaking. The
system automatically selects the fleet associated with the shortest
Slip Time as the one eligible to shake after this Slip Time has expired.
For details, see Slip-sweep (page 334).
Operation
Seismic setup options > Dynamic Fleet Grouping
286 428XL Users Manual Vol. 1
April 11, 2013
6
Dynamic Fleet Grouping
Figure 6-33
Choose this option for seismic recording techniques where you want the
system to built a fleet group dynamically with those fleets which are
ready to shake and far enough apart (see Dynamic Fleet grouping
page 329). You have to specify:
- Fleet Min Distance: how far apart fleets must be for the system
to allow them to shake simultaneously;
- Min number of Fleets: how many fleets at least should be
included in the group;
- Max number of Fleets: how many fleets at most should be
included in the group.
Guidance
Figure 6-34
This option (for VE432 or VE464 users only) causes a Latitude
Reference field to appear, used to specify the approximate latitude of
the centre of the spread (e. g. 475035.000 for 47 50 min 35 s). The
Latitude Reference is used to compensate for projection errors, for
locating the seismic crew more precisely. The closer the VPs to this
reference, the higher the guidance accuracy. Within 50 km of this
latitude reference, the effect of projection errors on the guidance
accuracy is negligible. See Vibrator Guidance (page 378).
Operation
Seismic setup options > Look option
428XL Users Manual Vol. 1 287
April 11, 2013
6
Note After enabling or disabling the Guidance option, you have to
go to Manual in the DPG window and run again the Set DSD
and Vib Fleet functions.
Look option
Figure 6-35
To open this setup window, select Options from the Setup menu. Click
on the Look tab. To enable and save your changes, click Apply.
This Seismic Setup is used for automation of Look and Sensor tests
between shot points.
The AutoLook option is used to enable or disable automatic
performance of a Look function between shot points. Tick this option
to select the Automatic mode, untick it for the Manual mode
(meaning that you will have to click on the Look button in the Line
main window). The status bar at the foot of the window has a field
that indicates if Autolook is enabled.
Every: This field is used to specify the recurrence rate of the Look
function if AutoLook is enabled. The selected tests will
automatically be launched after completing the number of shot points
specified in this field.
With Tests: These buttons allow you to choose one or more Sensor
tests to be performed by the Look function, in Automatic or Manual
mode.
Recurrence
every n VPs
Operation
Seismic setup options > Reshot option
288 428XL Users Manual Vol. 1
April 11, 2013
6
The Resistance and Tilt tests are done jointly: running either of them
also runs the other but, unless its button is activated the results from the
other test are not used.
Note If AutoLook is used, the acquisition cycle time is lengthened
by 0.5 second, plus the time that each test requested takes to
execute, that is:
- plus 1.5 s. if you select the Resistance and/or Tilt test;
- plus 1.5 s. if you select a Leakage test.
Note On a line segment including an LSI, the AutoLook function is
disabled: to see new FDUs, you must use manual Look in that
case.
Note The tests selected in the Look setup use the Gain code selected
in the Line main windows Test setup. If DSUs are used, it is
important to see if the Gain selected in the Test setup is the
same as that used in the production spread (because switching
the gain is time-consuming and also because it is preferable to
do the Tilt test with the gain used for production). See
Instrument tests (page 218).
Reshot option
Figure 6-36
By default, a warning dialogue box appears whenever you try to do
again any shot that has already been done. Ticking the Disable reshot
question option relieves you of the need to confirm whenever you want
to reshoot (the dialogue box will not be prompted); however, reshooting
gives rise to a notification in the status mail box.
Operation
The Source Type setup > Sources
428XL Users Manual Vol. 1 289
April 11, 2013
6
The Source Type setup
In this section:
Sources (page 289)
Explosive source parameters (page 290)
Vibroseismic source parameters (page 291)
Sources
Select Sources from the Setup menu. This setup window is used to
assign a name to each available seismic source and determine how the
system will select the next shot to do with that source from the operation
table.
The Explo option is for all types of impulsive energy (dynamite, air
gun, etc.). The Vibro option is for vibroseismic sweeps. For Explosive
shooting with a blaster controller within a line, see Shooting with an LSS
(page 311).
Figure 6-37
After entering all the parameters to define a type of seismic source, you
only need to enter a source type number in the Nb field, and click Add
then Apply to save the source type.
To view the parameters of any source type, double-click on it in the list
box (at the foot of the Setup window). Then you can make any changes
needed and click Change, or Add, or Delete, as required. To save your
changes, click Apply.
Operation
The Source Type setup > Explosive source parameters
290 428XL Users Manual Vol. 1
April 11, 2013
6
Explosive source parameters
Figure 6-38
To open this setup window, select Sources from the Setup menu, click
on the Explo tab.
Label
Use this field to enter a self-explanatory name that will identify the
source in plain (e. g. a shooters name).
Shooter Nb
Use this field to enter the identification number of the source controller.
Comment
Use this field to enter a description of the impulsive source in plain if
required.
Increment Nb
This field is used to specify the increment step to use after a shot is done,
to automatically determine which shot should next get the focus in the
list of shots to do. Typically the increment step is 1. An increment step
other than 1 is especially helpful in multishooter operations.
With 0 as Increment step, the Shot Number is not incremented after
a shot is done, and no new spread is formed.
With a Increment step other than 0 (a positive or negative integer),
the number of the next shot to do is computed accordingly, the focus
jumps to that shot, and the new spread is formed.
Operation
The Source Type setup > Vibroseismic source parameters
428XL Users Manual Vol. 1 291
April 11, 2013
6
Vibroseismic source parameters
To open this setup window, select Sources from the Setup menu and
click on the Vibro tab.
Figure 6-39
Label
Use this field to enter a self-explanatory name that will identify the
source in plain (e. g. a vibrator leaders name).
Fleet Nb
Use this field to enter the identification number of the group of vibrators
to use as the source. To determine which vibrators are included in each
fleet, use the VE464 Vibrator Fleet (page 537) or VE432 Vibrator Fleet
(page 655) function.
Moving: Sequentially
Choose the Sequential option if you wish to take VPs as scheduled in
the operation table.
After a VP is done, with this option, the system will use the increment
step specified in theStep field to determine which VP to do with this
source and select it automatically from the list of VPs to do.
If this source is for VPs with multiple acquisitions to stack, you may or
may not have to choose the Work by Acq option, depending on
whether or not you want to shift the fleets vibrators after each sweep.
Operation
The Source Type setup > Vibroseismic source parameters
292 428XL Users Manual Vol. 1
April 11, 2013
6
If a Ready message is received from a source, with no position
supplied, it only abridges the delay between shots but this does not
indicate the next shot to do.
The Type of Moving field is not available if Dynamic Fleet
Grouping is enabled in the Seismic setup options (page 281).
Moving: Randomly
Choose the Randomly option if you want to allow the Source Points to
get the focus in any order (e. g. if you are using a DSD network) rather
than follow the order determined in the list of shots to do. See
Navigation-driven shooting (page 309).
If this source is for VPs with multiple acquisitions to stack, you may or
may not have to choose the Work by Acq option, depending on
whether or not you want to shift the fleets vibrators after each sweep.
The Type of Moving field is not available if Dynamic Fleet
Grouping is enabled in the Seismic setup options (page 281).
Step
This field is used to specify the increment step to use after a VP is done,
if you choose Sequential as Moving option, to automatically determine
which VP should next get the focus in the list of VPs to do. Typically
the step is 1. An increment step other than 1 is especially helpful for
Flip-flop Vibroseismic operations (see Flip-Flop sweeps on page 321).
With 0 as step value, the Shot Number is not incremented after a VP
is done, and no new spread is formed.
With a step other than 0 (a positive or negative integer), the number
of the next VP to do is computed accordingly, the focus jumps to that
VP, and the new spread is formed. For an example with a negative
step, see Figure 6-63 on page 324.
The Step field is not available if Dynamic Fleet Grouping is
enabled in the Seismic setup options (page 281).
Operation
The Source Type setup > Vibroseismic source parameters
428XL Users Manual Vol. 1 293
April 11, 2013
6
Work by Acq
If this source is for VPs with multiple acquisitions to stack, you may or
may not have to choose the Work by Acq option, depending on
whether or not you want to shift the fleets vibrators after each sweep.
Untick Work by Acq if the multiple acquisitions are to be stacked
without shifting any vibrator. As a result:
- In the standard mode (no Slip-Sweep), the multiple acquisitions
to stack are done in succession, using the operator-selected delay
between acquisitions (see The Delay setup page 295), without
interleaving with other VPs.
- If Slip-Sweep is enabled and the acquisitions to stack are taken
without moving any vibrator, the vibrator fleet is implicitly
Ready at the end of each sweep (unless this is the last sweep
within the VP); therefore, it can shake as soon as the Slip Time
has expired. As a result, a VPs acquisitions will interleave with
those of other VPs.
Choose the Work by Acq option if the multiple acquisitions to
stack require the vibrator fleet to shift after each sweep. As a result:
- In the standard mode (no Slip-Sweep), after a sweep is done, the
focus will pass to the next VP determined with the increment
Step value (that may be a suspended VP with still a number of
acquisitions to do). As a result, a VPs acquisitions will
interleave with those of other VPs.
- With Slip-Sweep enabled, the focus may pass to whichever
vibrator fleet is ready to shake, if it falls inside the VP grabbing
circle, after the Slip Time has expired. As a result, acquisitions
can interleave with those of other VPs. For details on the VP
Grabbing Radius, see page 414.
Note To enable the system to open and suspend two or more VPs, see
428XL scalability (page 77).
The very first time any vibrator fleet is reported ready to shake at a
location that falls within the VP grabbing circle around a planned source
Operation
The Source Type setup > Vibroseismic source parameters
294 428XL Users Manual Vol. 1
April 11, 2013
6
COG position, that fleet is assigned to the first acquisition for that VP.
If the fleets position falls within more than one VP grabbing circles, a
dialog box pops up so the operator can choose between the eligible VPs.
The subsequent acquisitions to stack will be done by the same vibrator
fleet when it is next ready to shake within the same circle.
Cluster
If you want two (or more) VE464 sources to shake simultaneously,
those sources must have the same Cluster number, to be specified in
this field. See SQC Dump mode (page 348).
See also Manual clustering (page 327).
The Cluster field is not available if Dynamic Fleet Grouping is
enabled in the Seismic setup options (page 281).
Using two simultaneous sources is not allowed with the VE432.
Therefore, you must assign a different Cluster number to each VE432
source.
Comment
Use this field to enter a description of the vibroseismic source in plain,
if required.
Operation
The Delay setup >
428XL Users Manual Vol. 1 295
April 11, 2013
6
The Delay setup
To open this setup window, select Delay from the Setup menu.
Figure 6-40
At end of Acq: use this slider to set the required minimum time
between any two successive acquisitions to stack. This delay is not
used if the Manual automation option is selected (see Automation
page 282).
At end of VP use this slider to set the required minimum time
between any two successive VPs. This delay is only used if the
Continuous option is selected and no Break Point is set on the
selected VP.
Unless the Slip-Sweep mode is enabled, each delay is selectable from
0.0 to 99.0 seconds in 0.5-second steps. If any delay is set to the
maximum (99 seconds), then the system will keep waiting until an
External Go signal is received on the Blaster connector of the LCI.
If the Slip-Sweep (page 284) Standard Mode option is enabled, the
Delay setup window is used to adjust the Slip Time instead, which is
selectable from 1.0 to 99.0 seconds in 0.1-second steps.
Figure 6-41 Slip-sweep standard mode
Operation
The Delay setup >
296 428XL Users Manual Vol. 1
April 11, 2013
6
The Slip Time is used as follows: after a sweep is started, the Firing
Order for the next sweep will not be generated until a vibrator fleet is
ready to shake and the Slip Time delay has expired.
Note that the Slip Time delay should not be shorter than the desired
listening time.
If the Dynamic Slip-Sweep mode is enabled, the Delay setup allows you
to specify different Slip Times depending on the distance between fleets
(the farther apart the fleets, the shorter the required Slip Time). In the
Delay setup table:
The Distance in the first row must be 0;
The Slip Time in the last row must be 0.
Figure 6-42 Slip-sweep Dynamic mode
See Dynamic Mode (page 285) and Slip-sweep (page 334) for details.
Operation
The Noise Editing setup > Noise editing parameters
428XL Users Manual Vol. 1 297
April 11, 2013
6
The Noise Editing setup
In this section:
Noise editing parameters (page 297)
Noise editing thresholds (page 302)
Noise editing parameters
To open this setup window, select Noise Editing from the Setup
menu. To enable and save your changes, click Apply.
Figure 6-43
Prior to any processing, an offset correction operation is performed on
each sample:
A k i A k i
A k i
n
k
n
( , ) ( , )
( , )
=
=

1
For details about n, see Reference
Information in 428XL Users Manual Vol. 3
Operation
The Noise Editing setup > Noise editing parameters
298 428XL Users Manual Vol. 1
April 11, 2013
6
The stack formula is given below as a reminder:
A(k) =kth sample
n =number of samples in the acquisition
i =trace index
p =stack index
s =current stack fold
Noise Editing
(see also More About Noise Elimination page 388).
Historical
If you choose this option, then the noise editing function is enabled.
Then you must define the set of parameters which are necessary to
remove impulsive noise using an historical type of editing.
Diversity Stack
If you choose this option, then the Diversity Stack noise elimination
function is enabled. For this type of noise elimination, you are not
required to enter any parameter, apart from the Low Trace Percentage,
Low Trace Value and Nb of Windows.
The energy (E) from each trace is calculated by averaging the squares
of the samples (before correlation). Then each sample is multiplied by
the inverse of the energy previously computed.
At the end of s sweeps (when the VP is complete) each sample stacked
(before correlation) is multiplied by the inverse of the sum of the
inverses of the energies previously computed.
There's no peak editing function for that type of noise elimination.
A k i A k i p
p
s
( , ) ( , , ) =
=

1
Operation
The Noise Editing setup > Noise editing parameters
428XL Users Manual Vol. 1 299
April 11, 2013
6
Enhanced Diversity
Figure 6-44
This also enables the Diversity Stack noise elimination function, but
with this option a different calculation method is used. Rather than
specifying the required number of time windows, you specify the
required Window Length (which lets the system determine the number
of windows). Also, you may want windows to overlap by a certain
amount, which is adjustable with the Overlap Percent parameter.
The energy (E) from each trace is calculated by averaging the squares
of the samples (before correlation). Then each sample is multiplied by
the inverse of the energy previously computed.
At the end of s sweeps (when the VP is complete) each sample stacked
(before correlation) is multiplied by the sum of the inverses of the
energies previously computed.
There's no peak editing function for that type of noise elimination.
Off
If you choose this option, then the noise editing function is disabled, and
no parameters need to be defined.
Operation
The Noise Editing setup > Noise editing parameters
300 428XL Users Manual Vol. 1
April 11, 2013
6
Editing Type
Zeroing
If you choose this option, then any sample equal to or greater than the
editing threshold will trigger the process which zeroes the samples over
a window length that is selected by the Zeroing Length parameter.
Linear-variation taper, over a window selected by the Zeroing Taper
Length parameter, is programmed before and after the zeroed portion
in order to prevent discontinuity.
Clipping
If you choose this option, then every sample equal to or greater than the
threshold will be clipped to the editing threshold value by the noise
editing process.
Nb of Windows
(Allowable range: 1 to 64). Number of noise editing windows.
With the noise elimination function activated, the acquisition length
may be divided into one or more windows (1 to 64).
With Diversity Stack noise elimination and the Correlation Before
Stack processing option, a single window is used.
Zeroing Taper Length
2
n
(allowable range for n: 0 to 8). This parameter represents the number
of samples corresponding to the linear-variation taper length before and
after a zeroed window, when the Zeroing option is selected for the
Editing type parameter.
Zeroing Length
(Allowable range: 1 to 500 milliseconds). Zeroing window length when
a sample exceeds the editing threshold, when the Zeroing option is
selected for the Editing type parameter.
Operation
The Noise Editing setup > Noise editing parameters
428XL Users Manual Vol. 1 301
April 11, 2013
6
Threshold Init Value
(Selectable from 0 to -132 in 6-dB steps). Initialization value for all
noise editing thresholds and threshold types in all windows of every
channel, for Historical noise elimination.
Low Trace %
(Selectable from 0 to 100%). Criterion for deciding whether a channel
is Low. If the number (in percent) of samples which are below the
value specified in the Low Trace Value field exceeds the value
specified in the Low Trace % field, then the trace is reported as
Low.
If a trace is Low, threshold update is not performed at the end of the
sweep.
Low Trace Value
(Selectable from 0 to -132 in 6-dB steps). Upper limit for Low
channel detection. If any channel sample is less than or equal to this
limit, then the low channel detection process is triggered for the
corresponding channel.
Noisy Trace %
(Selectable from 0 to 100). Criterion for deciding whether a channel is
noisy. If the number (in percent, computed with respect to the
acquisition length) of zeroed or clipped samples exceeds the value
specified in the Noisy Trace % field, then the trace is considered as
noisy.
The corresponding trace number is simply reported in the observer's
log. No further action is taken (i.e. normal threshold updating takes
place).
Operation
The Noise Editing setup > Noise editing thresholds
302 428XL Users Manual Vol. 1
April 11, 2013
6
Noise editing thresholds
Clicking Manual isolates the Noise Editing process from the
preceding process stage and enables local functions for the management
of noise editing thresholds. As a result, data acquisition will be
suspended until you click Auto.
Clicking Auto connects the Noise Editing process to the preceding
process stage and allows data acquisition and processing to be
performed.
Figure 6-45
Hold/Var.
This button is used to enable or disable automatic updating of noise
editing thresholds in the Historical noise elimination process.
Choosing Var. enables thresholds to be automatically updated.
Choosing Hold causes thresholds to remain fixed at the latest value
updated before the Hold function was selected.
Init.
Clicking Init. presets all thresholds (64 windows) on all channels on
all threshold types (up to 16) to the initialization value entered for the
Historical noise elimination process.
Load
Clicking Load restores the latest noise editing thresholds saved, so
that they can be used as initialization values in the next Historical
noise elimination process.
Operation
The Noise Editing setup > Noise editing thresholds
428XL Users Manual Vol. 1 303
April 11, 2013
6
Save
Clicking Save saves all current noise editing thresholds so that they
can be used at a later date in Historical noise elimination.
This command should be used prior to turning the power off or prior to
taking a shot with a different geometry which could affect noise editing.
The Save command saves:
the threshold types used after power-on, or after clicking Init. or
Load, until Save is next used,
the traces used in each threshold type,
and the 64 windows on each trace (unused windows are initialized at
the threshold initialization value).
Operation
The Observers Comment Type Setup >
304 428XL Users Manual Vol. 1
April 11, 2013
6
The Observers Comment Type Setup
Selecting Comments from the Setup menu opens this window that
allows you to incorporate favourite comments of your own. Using this
function, you can easily and faster insert comments into your Obs Log.
These comments are not copied to the SEGD file.
Figure 6-46
Any ASCII character is allowed except double quotation marks ().
Once you have entered a comment in the upper pane, enter a Number
and Label in the respective text boxes in the lower pane, and click
Add (or Change, as required) to add the new comment type into
the list box.
The comments you create in this setup are available from the right-click
popup menu in The Operation Report view (page 255) so that you can
choose one and insert it into the reports Comment field.
Click Apply to save your changes.
Operation
How to take shots or sweeps > Blaster shots
428XL Users Manual Vol. 1 305
April 11, 2013
6
How to take shots or sweeps
In this section:
Blaster shots (page 305)
VE432 or VE464 sweeps (page 307)
Navigation-driven shooting (page 309)
Multiswath (page 310)
Shooting with an LSS (page 311)
Blaster shots
Shooting system not supplying the Shooter position
If the shooting system does not supply the position of the blaster, an
audio radio channel is required for the shooter to tell you when he is
ready to shoot and which Source Point to shoot. If this is the first shot
to do with this shooter, you have to right-click on the Source Point in
the Operation table and select the shooter from the pop-up menu. As a
result, the focus passes to that shooter and Source Point in the Active
Source view. Clicking Go will send a message to the blaster and
launch the acquisition.
After a shot is done, the system uses the operation table and the
increment Step associated with the Source to determine which shot
should next get the focus (appearing in the Active Source view). Then
you only need to click Go when the shooter says he is ready, unless
you want to choose another shot (by clicking) and shooter (by right-
clicking) in the operation table.
Shooting system supplying the Shooter position
All available shooters (sources) are displayed without any Shot Point
number being associated to them until the GUI receives a Ready
status (together with a GPS position) from the shooting system (SGD-S
or AWD).
Operation
How to take shots or sweeps > Blaster shots
306 428XL Users Manual Vol. 1
April 11, 2013
6
After a Ready status is received from a shooter, the system
automatically selects the Shot Point that matches the GPS location, and
the focus goes to the corresponding Source in the Active Source view.
If the Rdy pushbutton for that Source name is released, an R
appears in it and the Ready notification is blocked until you accept it
(by clicking on the pushbutton). Then you just have to click Go to
send the firing order to the blaster and launch the acquisition.
If two or more shooters are ready, the system selects the Shot Point
corresponding to the latest Ready notification. All available sources
are allowed, so you can choose whichever you like.
If no GPS position is received along with the Ready status (e. g.
because of radio interference), then the corresponding source is selected
in the Active Source view but no Shot Point is selected. In that case, you
know which shooter is ready but you have to specify which SP to shoot
(using the right-click popup menu to associate a Source Point with the
shooter). After choosing the Shot Point, click Go to send the firing order
to the blaster and launch the acquisition.
In the case of an Accelerated Weight Drop (AWD) source, the stack
number is notified to the shooter, which allows the driver to determine
whether all the acquisitions are completed in a shot point, and whether
he should move to another source point.
Operation
How to take shots or sweeps > VE432 or VE464 sweeps
428XL Users Manual Vol. 1 307
April 11, 2013
6
VE432 or VE464 sweeps
The Process Type associated with each Source Point in the operation
table is itself associated with an Acquisition Type that determines
which sweep signal to generate. The Active Acquisition view lets you
see which acquisition is in progress.
In Vibroseismic operations, the way the focus passes from a VP to
another depends on the options you choose in Seismic setup options
(page 281) and The Source Type setup (page 289):
In the standard mode (no Slip-Sweep, actual vibrator positions not
available), the system relies on the Operation Table and on the
parameters associated with the source (increment Step, Moving
and Work by Acq options) to determine which VP should next get
the focus after an acquisition is done. Up to four sources can be used
alternately (see Flip-Flop sweeps on page 321). With the VE464, up to
four sources can be used simultaneously (see Cluster on page 294).
If Slip-Sweep is enabled but actual vibrator positions are not
supplied, the system relies on the Operation Table to determine which
VP should next have the focus after an acquisition is done. Stacking
is not allowed. See Slip-sweep (page 334).
If actual vibrator positions are supplied, VPs are not necessarily done
as scheduled in the Operation Table. When a fleet is ready to shake
and its COG lies in the vicinity of a planned source point to be done
with that fleet, the system automatically selects and highlights the
matching VP in the operation table, regardless of which VP is next
scheduled. See Navigation-driven shooting (page 309).
Below is a reminder of the available methods of starting sweeps
automatically when a fleet is Ready at a planned source position. A
vibrator is not Ready, and pressing the Ready button on the DSD has
no effect, unless and until its pressure sensor says the pad is down if
a pressure sensor is used. In the case of a WIFI-networked fleet, the fleet
is not Ready until the Leader DSD is notified by WIFI of all the other
DSDs in the fleet having their pads down, and its own pad is down.
Operation
How to take shots or sweeps > VE432 or VE464 sweeps
308 428XL Users Manual Vol. 1
April 11, 2013
6
Note (1) In that case, the arrival of the Ready status overrides the
operator-selected delay.
Note (2) The VE432 or VE464 DSD Network option (see
page 500) allows each vibrator to supply its GPS position.
When a vibrator fleet is ready (pads down) the leader sends a
message containing both the Ready status and the resulting
Centre Of Gravity of the source, calculated from the GPS
position of each vibrator. This enables the system to
automatically select the matching source point in the Operation
Table. This way of shooting is referred to as the source
Navigation-driven shooting (page 309) mode (or more simply
Navigation mode). If the COG falls outside the programmed
circle, then a warning dialog box shows up: click OK if you
choose to accept the source position as it is, Cancel otherwise
(in that case the system will wait for the next fleet to be ready).
Note (3) In the VE432 or VE464 main window, a button is associated
with each fleet, enabling the Fleet Ready status to be relayed
automatically to the Operation window, or blocked until you
choose to let it go.
Note (4) If for any reason you need to redo a sweep, you do not need
to cycle the vibrator pad Up/Down: simply press the Ready
button on the DSD (on the Leader DSD in the case of a WIFI-
networked fleet).
Source Moving option (Source Type setup menu)
Sequentially Randomly
(VE432 or VE464 DSD network)
Standard Slip-Sweep
(VE432 or VE464)
Navigation Navigation & Slip-
Sweep
Sweep start
conditions
- Vib. Fleet Ready.
Or
- Delay between
Acquisitions or VPs
expired.
(See Note 1)
Slip Time expired. - Vib. Fleet Ready
And
- Source COG
matching planned
VP.
(See Note 2)
- Vib. Fleet Ready
And
- Source COG
matching planned VP
And
- Slip Time expired.
(See Note 2)
Operation
How to take shots or sweeps > Navigation-driven shooting
428XL Users Manual Vol. 1 309
April 11, 2013
6
Navigation-driven shooting
(for VE432 or VE464 users only).
If you enable sources to move randomly rather than sequentially (see
Moving: Randomly page 292) and a GPS receiver is attached to each
DSD, then you can use the Navigation-driven shooting (or more
simply Navigation) mode.
The Navigation mode relies on the VE432 or VE464 DSD Network
option that allows the geographical location of a vibrator fleet
(computed by the fleets leader and referred to as source COG) to be
relayed to the 428XL system as soon as all the vibrators in the fleet are
ready, with their pads down. Then the 428XL can select the matching
VP (shot point) from its operation table and shoot it automatically. As a
result, VPs can be shot in any order by any fleet.
Note The COG displayed in the Positioning main window is
computed from the status messages sent by the DSDs to the
DPG after sweeping.
The requirements for the Navigation-driven shooting mode are the
following:
- Cable telemetry configuration.
- Single fleet for each VP.
- With the VE432, a single source for each VP.
- Continuous mode activated.
- Planned source geographical positions (from SPS files)
imported into the Positioning window.
- VE432 or VE464 DSD Network option implemented (see
VE432 or VE464 Manual).
See also VE432 or VE464 sweeps (page 307).
Operation
How to take shots or sweeps > Multiswath
310 428XL Users Manual Vol. 1
April 11, 2013
6
Multiswath
If you have two or more swaths to shoot:
1. Go to Field Off in the Line or Positioning window.
2. Set each swath to use to Active in the Config windows Swath
setup (page 97).
3. In the Log window, load all the SPS files to use. For each SPS file,
select the appropriate swath number from the drop-down list in
the toolbar and click on Apply. See Importing an SPS file
(page 583).
4. In the Operation window, open your preferred type of view (All
VPs, or VPs to do, etc.) for each swath to shoot.
Figure 6-47
5. In the Active Source view, use the Associate VP right-click
shortcut to enter the number of the Swath and the next VP to do
for each source.
Figure 6-48
Operation
How to take shots or sweeps > Shooting with an LSS
428XL Users Manual Vol. 1 311
April 11, 2013
6
If shots are taken sequentially (see Moving: Sequentially page 291),
each source will remain associated with the swath you select with the
Associate VP right-click shortcut.
If you are using the Navigation-driven shooting mode (see Moving:
Randomly page 292), then two cases must be distinguished when a
Ready is received in the Active Source view:
- if the source is already associated with a VP in a swath, then the
source will do a VP in the same swath;
- if the source is not associated with any VP, then the system asks
you to specify which swath to do next.
Shooting with an LSS
Overview
Figure 6-49
HSU
LSI
LRU
Blaster controller
You can connect another
shooting system on the second
Blaster connector
Operation
How to take shots or sweeps > Shooting with an LSS
312 428XL Users Manual Vol. 1
April 11, 2013
6
The LSS (Line Shooting System) allows you to use the 428XL
telemetry network rather than a radio link to synchronize a remote
shooting system with the recording truck, for example in situations and
over stretches of land where radio communications are difficult.
Shooting with an LSS does not require any audio communications
between the observer in the recording truck and the shooter. The LSS
consists of an LSI unit associated with an HSU.
The LSI (Line/Source Interface) allows you to connect a blaster
controller along an acquisition line instead of connecting it to the
control units Blaster connector. It acts as a remote Blaster connector.
The HSU (Hand-Shake Unit) is used by the shooter to supply the
status of the firing device and the number of the corresponding shot
point to the central unit.
For details on how to connect the HSU to the blaster controller, see
428XL Installation Manual.
Note On a line segment including an LSI, the Autolook function is
disabled: to see new FDUs, you must use manual Look in that
case.
Note Instrument tests on LSI channels need a special procedure (see
Instrument tests on LSI channels on page 318).
Note Neither the LSI nor the HSU can be tested with an LT4208. If
an LSI is encountered on the line segment, it is viewed as two
FDUs on the LT428. The serial number of the LSI is displayed
in the RCV field with LS as a prefix.
Note The dual-channel FDU inside the LSI cannot be calibrated with
the TMS428 system.
LSS FO/TB delay calibration
With a shooting system connected to an LSS, the shooting systems
delay between the FO (Firing Order) and PTB (Predicted Time Break)
must be known prior to shooting.
Operation
How to take shots or sweeps > Shooting with an LSS
428XL Users Manual Vol. 1 313
April 11, 2013
6
This delay must be entered in the TB Window field of the Process
Type used to shoot (see TB Window on page 258). To calibrate the FO/
TB delay, use the following procedure:
1. Connect the blaster controller to one of the Blaster connectors of
the LCI (use the normal interface cable). Insert the LSI into a line,
and connect the HSU to the LSI.
2. Define an explosive Process Type using the connected Blaster
plug, and enter 0 into the TB Window field of this Process Type.
Use the Explo LSI tab in the Source Type setup to create a
shooter.
3. The shooter should send the stack number by pushing the Send
button on the HSU, causing a red arrow to appear in the Active
Source view in the Operation window. The observer should
double-click on this red arrow, then the shooter should push the
Arm Set button on the HSU.
4. Click Go in the Operation window to take a dummy shot using the
Process Type created in step 2. A message should appear in the
status pane, displaying the value of the FO/TB delay measured by
the system:
FO / TB delay measured = xxxxxxx micro seconds
5. Enter that value (in milliseconds) into the TB Window field of the
Process Type used for shooting with LSS.
Example: with Shot Pro Encoder Time adj =0.5 ms, Rad Ref
delay=1.9ms and Vertex2000 radio: FO/TB Delay=1000.583ms.
Taking a shot with an LSI
Prerequisites
1. To enable shooting with LSI units, you must select the LSI
option and the type of blaster in the Install main window. See
Blaster type (page 72).
With the LSI option enabled:
Operation
How to take shots or sweeps > Shooting with an LSS
314 428XL Users Manual Vol. 1
April 11, 2013
6
- the indicator LED on FDUs, otherwise used as a test result
indicator, is used to tell the shooter whether he is allowed to
connect/disconnect an LSI between two links.
- you cannot take a shot until retrieval of the previous one is
complete, whatever the field equipment and the shooting method
used.
2. The delay between the Firing Order and the predicted Time Break
is assumed known and invariable. See LSS FO/TB delay calibration
on page 312. It must be entered into the TB Window field (see TB
Window on page 258).
3. Use The Source Type setup (page 289) menu to assign a Shooter
name to the LSI to use, and choose the desired gain for the Uphole
and CTB channels.
Figure 6-50
Until the LSI is inserted into a line, a No entry traffic sign is
displayed ahead of it in the Active Source view.
Figure 6-51
LSS shooter 1
LSS shooter 1
LSS shooter 2
LSS shooter 1
Not connected
Operation
How to take shots or sweeps > Shooting with an LSS
428XL Users Manual Vol. 1 315
April 11, 2013
6
Step-by-step operating instructions
Below is the typical step-by-step procedure for a shooter to insert an
LSI into the spread and for an observer in the recording truck to take a
shot using that LSI.
1. Observer: go to Field On (unless already
done) in the Line main window.
2. Shooter: locate the junction of the two FDU links where to insert
the LSI, and check to see if the indicator LED on FDUs is
blinking.
Figure 6-52 Unplugging is allowed
When FDU indicator LEDs are blinking, disconnect the links and
connect the LSI in between. The Line OK indicator should light
up.
Figure 6-53 LSI connected
3. Observer: Click on Look in the Line main window to view the
LSI channels connected.
In the Active Source view, the No entry sign is replaced by a
red arrow sign meaning that the LSI is present. Be sure the Rdy
(Ready) button is activated. This will enable the system to
automatically select the shot point to do when the shooter says he
is ready.
Blinking Blinking
Line OK
Operation
How to take shots or sweeps > Shooting with an LSS
316 428XL Users Manual Vol. 1
April 11, 2013
6
Figure 6-54
4. Shooter: Dial the Shot Point number, using the knobs on the
HSU. Press the Send button.
Figure 6-55
5. Observer: The focus goes to the selected shot point in the
Operation table. The selected source point is displayed in the
Active Source view. When you want to accept the shot point and
allow the shooter to arm the blaster, double-click on the left-hand
status indicator.
Figure 6-56
6. Shooter: The indicator on FDUs stops blinking. The spread is
formed.
When the Observer accepts the shot point as explained in the
previous step, the Arm enable indicator should light up on the
HSU. It is important to wait for Arm enable to light up for
LSS shooter 1
Connected
Enabled
Dial Shot Point
number
Push Send
LSS shooter 1 25 1 1 25
Shot Point to do
Double-click
to enable arming
Operation
How to take shots or sweeps > Shooting with an LSS
428XL Users Manual Vol. 1 317
April 11, 2013
6
correct synchronization of the Time Break. Then press Arm set
on the HSU.
Figure 6-57
7. Observer: In the Active Source view, the status indicator must
have changed from red to yellow. Click Go. This triggers the
firing device.
Figure 6-58
8. Shooter: The Arm enable indicator on the HSU goes out.
After the seismic data is retrieved, the Disconnect enable
indicator on the LSI lights up, and FDU indicators are again
blinking, meaning that the shooter can unplug the LSI and move it
to another location if required.
Note
1. The Up-Hole and CTB (Confirmed Time Break) auxiliary traces
from the LSI are acquired with the same Sample Rate and filter
type as seismic traces.
2. You can have both ways of shooting available (via an LSS and via
a radio link) and use whichever is most appropriate, at your own
convenience. In that case, be sure the value used as TB Window
for LSS-fired shots does not give rise to any ITB error for
Push Arm set
LSS shooter 1 25 1 1 25
Click
Operation
How to take shots or sweeps > Shooting with an LSS
318 428XL Users Manual Vol. 1
April 11, 2013
6
radio-fired shots. (If an ITB arises, define a Process Type for LSS-
fired shots and another one for radio-fired shots). Also, remember
that whenever you select an LSI shooter, the Up-Hole and CTB
traces from the LSI are systematically placed ahead of the
Auxiliary traces from the blaster controller connected to the LCI,
and they are recorded as a1 and a2 in the SEGD file.
Therefore you have to do as follows:
- In the Layout setup, define the auxiliary channels for radio-fired
shots as a3 (for Shot Pro Analog Data or Macha UH
signal) and a4 (for Shot Pro TB or Macha FTB signal).
- In the Process Type used in common, define only a3 and a4
in the description of auxiliary traces.
3. The shooter can use the rotary switches on the HSU to send
messages (user-reserved shot point numbers) to the recording
truck if audio communications are totally impossible. For
example, the following code can be adopted:
- 999999: Emergency alert.
- 777777: Shot point not found (Skip Shot Point).
- 555555: Cap test failure, or shot not loaded (Skip Shot Point).
- 333333: Moving up LSI.
- 111111: Technical trouble.
4. See Source controller formats in Users Manual Vol. 3 for the
fields updated with the messages from the source controller.
Instrument tests on LSI channels
LSI channels are not tested through a standard Instrument Test. To
perform an Instrument test on LSI channels, do the following:
1. Enter the two LSI channels as Aux channels (e. g. a1 and a2) in
the Layout - Aux - Setup menu. See page 139. (To find the Serial
Number of the LSI channels, double-click on the LSI icon in the
graphic view, or open an Instrument Numeric view).
Operation
How to take shots or sweeps > Shooting with an LSS
428XL Users Manual Vol. 1 319
April 11, 2013
6
2. Launch the Instrument test.
More about the Shot Pro blaster controller
You can have both ways of shooting available (via an LSS and via a
radio link) and use whichever is most appropriate, at your own
convenience. In that case, with Shot Pro blaster controllers, the
following points should be borne in mind:
With LSS-fired shots, the serial line from the Shot Pro Encoder is not
supported. As a result, the Shot Pro Encoder does not return any
ASCII message (for shot point position, TB, UH data) via the serial
ports of the HSU.
For a radio-fired shot, selecting a Shooter name in the Operation main
window initializes the Shot Pro Encoder (through the serial port of
the Encoder). As a result the Encoder assumes the sequential number
of the selected shooter from the shooter list as Shot Pro Encoder
number. Therefore, you must make sure the right Box Id is associated
with it on the Shot Pro Decoder.
A distinct setting is required for the Encoder and Decoder used for
LSS-fired shots: the Start Code should be different from that used for
radio-fired shots, and the Box Id of the Decoder should be used as
Shot Pro number of the Encoder (e. g. Box Id. =10 and
Encoder No. =10).
The LSI shooter appears at the top (Number 1) position in the list of
shooters in the Operation main window, therefore the first radio
shooter appears as Number 2.
Figure 6-59
LSI connected LSI not connected
Shooters list Encoder No. Shooters list Encoder No.
LSI shooter 10 Radio shooter 1 1
Radio shooter 1 2 Radio shooter 2 2
Radio shooter 2 3
Operation
How to take shots or sweeps > Shooting with an LSS
320 428XL Users Manual Vol. 1
April 11, 2013
6
As a result the shooters list (i. e. the Encoder No.) is shifted every time
you connect or disconnect the LSI, meaning that you have to change the
Box Id of the radio Decoders accordingly, unless you delete the LSI
from the Shooter setup window whenever radio-fired shots are taken.
Therefore, the following rule is recommended: for radio-fired shots,
delete the LSI from the Shooter setup window, regardless of whether the
LSI is connected or not.
Operation
Flip-Flop sweeps >
428XL Users Manual Vol. 1 321
April 11, 2013
6
Flip-Flop sweeps
What is meant by Flip-Flop mode with the 428XL is the use of
multiple sources alternately (not only two, but up to four).
Flip-flop with two sources
A simple textbook example of Source Type setup for flip-flop
operations is shown in Figure 6-60 where two sources (Source1 and
Source2) are alternately generated by two vibrator fleets (respectively
F1 and F2). In this example, no stacking is requested.
Figure 6-60 Typical Flip-Flop, no stacking
Source1
Source2
Source1
Source2
2
2
3 1 1 Dump
Source1 2 1
1 3 1
2 4 1
Source1
Expired delay F2 Ready F2 Ready F1 Ready
F1 moving to
VP5 location
Source2
VP3 (Acq1)
VP4 (Acq1)
F2 moving to
VP6 location
VP5 (Acq1)
F1 moving to
VP7 location
VP6 (Acq1)
Operation
Flip-Flop sweeps >
322 428XL Users Manual Vol. 1
April 11, 2013
6
With the above settings, if you right-click on VP3 and choose Start
Seismonitor with Vib Source1, and right-click on VP4 and choose
Start Seismonitor with Vib Source2, then the system will do VP3
with fleet #1, VP4 with fleet #2, VP5 with fleet #1, and so on.
In the example shown in Figure 6-61 below, the same scheme is used but
two acquisitions are stacked at each VP without shifting the vibrators.
Figure 6-61 Flip-Flop, stacking with no vib shift
With the above settings, if you right-click on VP3 and choose Start
Seismonitor with Vib Source1, and right-click on VP4 and choose
Start Seismonitor with Vib Source2, then the system will do two
Source1
Source2
Source1
Source2
2
2
3 1 2 No Dump
Source1 2 1
1 3 1
2 4 1
Source1
Expired
delay
F1 moving to
VP5 location
Source2
VP3 (Acq1)
3 2 2 Dump
VP3 (Acq2)
VP4 (Acq1)
Expired
delay
VP4 (Acq2)
VP5 (Acq1)
Expired
delay
F2
Ready
F1
Ready
F1
Ready
Expired
delay
Operation
Flip-Flop sweeps >
428XL Users Manual Vol. 1 323
April 11, 2013
6
stacked acquisitions for VP3 with fleet #1, and then two stacked
acquisitions for VP4 with fleet #2, two stacked acquisitions for VP5
with fleet #1, and so on.
In the example shown in Figure 6-62 below, the Work by Acq option
is used. As a result the two acquisitions to stack are not done in
succession: while the vibrators are shifting to the location of the second
acquisition, the system takes an acquisition for another VP.
Figure 6-62 Flip-Flop with Work by Acq option
With the above settings, if you right-click on VP3 and choose Start
Seismonitor with Vib Source1, and right-click on VP4 and choose
Start Seismonitor with Vib Source2, then the system will do the
Source1
Source2
Source1
Source2
2
2
3 1 2 No Dump
Source1 2 1
1 3 1
2 4 1
Source1
F1 moving to
VP5 location
Source2
VP3 (Acq1)
3 2 2 Dump
VP3 (Acq2)
VP4 (Acq1) VP4 (Acq2)
VP5 (Acq1)
F2
Ready
F1
Ready
Expired
delay
F1 shifting
F2 shifting
F2
Ready
VP6 (Acq1)
F2 moving to
VP6 location
Operation
Flip-Flop sweeps >
324 428XL Users Manual Vol. 1
April 11, 2013
6
first acquisition for VP3 with fleet #1, and then the first acquisition for
VP4 with fleet #2 (while a pause icon appears ahead of VP3), and
resume VP3 with fleet #1 (while a pause icon appears ahead of
VP4), resume VP4 with fleet #2, and so on and so forth.
Note To enable the system to open and suspend two or more VPs, see
428XL scalability (page 77).
Note You can use a positive or negative value in the Step field.
In the example in Figure 6-63 below, the two source are moving in
opposite directions because a negative Step is used for source #2.
Figure 6-63 Negative Step
2nd acq. in
progress
1st acq. done
To do with
source #2
In progress
(source #1)
Negative step
Done
(source #2)
Operation
Flip-Flop sweeps >
428XL Users Manual Vol. 1 325
April 11, 2013
6
Flip-flop with three or four sources
The above simple schemes can be extrapolated to four sources.
Note If you want to use three or four sources with the Work by Acq
option, you have to use the Administration window to set the
Maximum open VP parameter (2 by default) to 3 or 4. See
428XL scalability (page 77).
In the example shown in Figure 6-64 below, the system will do only two
VPs out of four because the Step field is set at 4 but only two sources
are used. You still have to choose the first VP to do with source #2
(using the right-click popup menu) and that with source #4.
Figure 6-64 Flip-flop, 4 sources, with Work by Acq option
Not used
Not used
2nd acq. in
progress
1st acq. done
Suspended
In progress
Operation
Simultaneous sources >
326 428XL Users Manual Vol. 1
April 11, 2013
6
Simultaneous sources
For operation modes using simultaneous seismic sources, you can
manually create a fleet cluster specifying which fleets are expected to
shake simultaneously, or let the system automatically build a fleet
group. Each fleet may consist of one or more vibrators.
Manual clustering (page 327) is suitable for a cluster invariably
consisting of the same vibrators, like for example in SQC Dump mode
(page 348).
Figure 6-65 Manual clustering
The Dynamic Fleet grouping (page 329) option is suitable for seismic
recording techniques where you want the system to built a fleet group
dynamically with those fleets which are ready to shake and far
enough apart.
Figure 6-66 Dynamic fleet grouping
The Autonomous mode (page 373) allows simultaneous-source
shooting, with sweeps being launched independently by pressing the
Ready button on the DSD of each fleet leader.
1
2
3
4
5
6
7
8
9
Cluster 1 Cluster 2 Cluster 3
Fleet 1
Fleet 2
Fleet 3
1
2
3
4
5
6
7
8
9
Area 1 Area 2 Area 3
Operation
Simultaneous sources > Manual clustering
428XL Users Manual Vol. 1 327
April 11, 2013
6
Manual clustering
When used with a VE464, the system can record acquisitions from up
to 32 simultaneous sources and generate an SEGD file for each source.
For sources to start shaking simultaneously, the following is required:
Create the necessary sources in the Source Type setup, and specify
which fleet to use for each source.
Figure 6-67
- Assign the same Cluster number to all the fleets to use. This will
allow the sources to shake simultaneously.
- Set the Moving option as required. If you choose Sequential
then the Step should be equal to the number of sources.
The shot points you want to do with the simultaneous sources must
have the same Process Type number. To specify the Process Type,
use The Source Point Setup (page 275) setup window.
You must associate each source with a shot point in the operation
table (using the Start Seismonitor with Vib Source right-click
shortcut in the All VP or VP to do view, or using the Associate
VP shortcut in the Active Source view).
In Navigation-driven shooting mode, you set the Moving option to
Randomly. In that case, you need to use the Start or Associate
shortcut only once, and you can choose any shot point (the system will
not associate a source with a shot point unless and until it receives a
Ready message from the fleet, and only those sources from which a
Ready message is received will be allowed to start shaking).
Same Cluster
Operation
Simultaneous sources > Manual clustering
328 428XL Users Manual Vol. 1
April 11, 2013
6
Figure 6-68
If several sources are used simultaneously but, for any reason, you want
to silence one of them for a number of acquisitions, you simply have to
disassociate it (with the right-click menu in the Active Source view).
Same
Process
Type
Simultaneous
sources
Operation
Simultaneous sources > Dynamic Fleet grouping
428XL Users Manual Vol. 1 329
April 11, 2013
6
Dynamic Fleet grouping
The Dynamic Fleet Grouping option in the Seismic setup options
(page 281) is intended for seismic recording techniques where you want
the system to built a fleet group dynamically with those fleets which are
ready to shake and far enough apart. This option is associated with three
parameters:
If a minimum distance is required between fleets shaking at the same
time, the Fleet Min Distance specifies how far apart fleets must be
for the system to allow them to shake simultaneously. The system
uses the GPS position included in the Ready messages collected from
vibrators to calculate how far apart they are from one another, and
automatically determines the eligible vibrators. The selection process
also has to ensure that vibrators are equally used, and prevent
selecting vibrators converging to the same area. Priority is given to
those vibrators that sent a Ready message first.
The Min number of fleets specifies how many fleets at least should
be included in the group;
The Max number of fleets specifies how many fleets at most should
be included in the group.
When Dynamic Fleet Grouping is enabled, the Type of Moving,
Step and Cluster parameters in the Source Type setup window are
irrelevant, therefore not prompted.
Figure 6-69 Source Type Setup for dynamic fleet grouping
Operation
Simultaneous sources > Dynamic Fleet grouping
330 428XL Users Manual Vol. 1
April 11, 2013
6
Note that priority is given to the group that has the largest number of
fleets. If two or more groups have the same number of fleets, priority is
given to the group with the oldest age of Ready fleets.
First step: manual selection
Below is an example with 8 vibrators or fleets and the following
settings:
- Min Number of Fleets =Max Number of Fleets =3
- Fleet Min Distance =250 m.
In the Positioning window, flags indicate which vibrators are ready to
shake (after a Ready message has been received from those vibrators).
Figure 6-70 Positioning window
In the Operation window, when a Ready message is received from a
vibrator or fleet, the system automatically associates a source point (i. e.
a VP) with it. You can also manually associate a vibrator with a source
point by using the right-click popup menu in the Operation table as
usual, or by drag-and-drop of a flag to a source point in the Positioning
window.
So long as no group is available, the Go button is dimmed. To select
which vibrators will start shaking, do the following:
Operation
Simultaneous sources > Dynamic Fleet grouping
428XL Users Manual Vol. 1 331
April 11, 2013
6
1. Select a vibrator from those ready by clicking in its row in the
Operation table. When a vibrator is selected (e. g. Vib 1 in
Figure 6-71 on page 331), a green arrow appears in the leftmost
column in the Active Source view, and the rows colour changes
to light blue. The minimum distance from other vibrators that are
ready to shake is displayed in the Dist Min column. The eligible
vibrators (i. e. which are far enough apart from those already
selected) are displayed as green rows (from light green for the
nearest ones to dark green for the farthest ones), meaning that they
can be added to the current selection.
Figure 6-71 Active Source view
2. Select a second vibrator (e. g Vib 7). As a result the Dist Min
column is updated. In Figure 6-72, Vib 4 is no longer eligible
because it is too close (200 m) to Vib 7.
Figure 6-72
Selected
Eligible
Selected
Eligible
Selected
Operation
Simultaneous sources > Dynamic Fleet grouping
332 428XL Users Manual Vol. 1
April 11, 2013
6
3. In this example, the group must include at least (and at most) three
vibrators. Let us assume you select Vib 6 as third vibrator in the
group. As a result, the Go button is undimmed, meaning that the
group is complete. Clicking on Go will cause Vib1, vib 6 and
Vib7 to start shaking.
Figure 6-73
Note that if, instead of clicking on Go when the group is complete, you
select one more vibrator, the system dismisses the former group
selection and starts a new one beginning with that vibrator.
Second step: automatic selection
The system waits until a new fleet group can be built and all previous
operations are complete, then it automatically launches the
simultaneous sweeps with the new group.
For each fleet that is ready in the Active Source view, the Dist Min
column indicates its minimum distance from any fleet currently shaking
or included in a group currently being built. Each row where that
distance is greater than the specified Fleet Min Distance is displayed in
green (from light green for the shortest separation to dark green for the
longest one).
In Figure 6-74 on page 333, acquisition is in progress with Vib1, Vib5
and Vib9. Note that the Ready flag in the Rdy column has been
cleared for these three vibrators.
Selected
Selected
Selected
You can click on Go
Operation
Simultaneous sources > Dynamic Fleet grouping
428XL Users Manual Vol. 1 333
April 11, 2013
6
Vib 2 cannot be selected for the next group, although a Ready was
received from it, because its Ready button has been released (Ready is
blocked), and also because it is less than 150 m away from the eligible
vibrators (Vib4 and Vib6).
Vib 3 cannot be selected because it did not send any Ready after doing
its latest sweep (shot number 1,628).
Vib 4 can be selected for the next group.
Figure 6-74
Vib 6 can be selected, as it is ready and far enough from Vib4, but it
will not be selected until its Ready button is clicked (presently its Ready
is blocked).
Vib 7 cannot be selected for the next group because it is too close to the
eligible vibrators (227 m).
No source point is associated with Vib 8 because no Ready was yet
received from it (or it has been disassociated).
In progress
In progress
Too close
Blocked
Ready
Eligible
In progress
Operation
Slip-sweep > Theory of operation
334 428XL Users Manual Vol. 1
April 11, 2013
6
Slip-sweep
(For VE432 or VE464 users only). In this section:
Theory of operation (page 334)
How to implement slip-sweep (page 336)
Standard Slip-Sweep mode (page 339)
Allowable minimum distance between simultaneous sources (page 343)
Dynamic Slip-Sweep mode (page 345)
Theory of operation
With the slip-sweep option enabled, the system lets a vibrator fleet start
sweeping without waiting for the previous fleet's sweep to be
completed. The system only waits until a delay (Slip Time) specified by
the operator has expired the estimated time for a given frequency in
the previous sweep to die out and lets the next vibrator fleet start
sweeping when it is ready, with the appropriate receiver stations
activated. For this technique to work properly, a minimum distance is
required between the fleets shaking simultaneously (see Allowable
minimum distance between simultaneous sources page 343).
The system cuts the acquisition data flow at the appropriate time-zeroes.
The data appear in SEGD files as individual correlated records.
Figure 6-75 VE464 (version 3.0 or above)
Fleet 2 sweep
Fleet 3 sweep
Slip Time
Slip Time
Fleet 1 sweep
Slip Time
Slip Time
Fleet 1
Ready
Fleet 3
Ready
Fleet 2
Ready
Fleet 2
Ready
Fleet 3
Ready
Fleet 1 sweep
Fleet 2 sweep
TB
TB
TB
TB
TB
TB
Operation
Slip-sweep > Theory of operation
428XL Users Manual Vol. 1 335
April 11, 2013
6
The Slip Time is regarded as the minimum time between a Time
Break (TB) and the next one. Unless the VE464 has to wait for the
Firing Order (for example because no fleet is ready), the time between
two TBs is always minimum and equal to the Slip Time. Vibrators are
not allowed to start sweeping automatically unless they send a Ready
message.
Note With a VE432 or earlier VE464 version (less than 3.0), the
Slip Time is the time between a TB and the next FO. After
the Slip Time has expired and the Firing Order is generated, the
time required for the DPG to send the Time Break depends on
the number of T
0
codes used to synchronize the vibrators.
With two T
0
sync codes, the FO to TB time is about 1.5 s, i. e. T =2s
approximately. See the T
0
Setup in the VE432 DPG main window
(page 646).
Figure 6-76 VE432 (or VE464 version less than 3.0)
Each VE432 vibrator fleet you want to use in slip-sweep mode must
have its own vibrator controller (DPG). Since up to four VE432 DPGs
can be attached to the system, you can use up to four fleets in slip-sweep
mode.
Slip-Sweep requires a single VE464 DPG, regardless of how many
vibrator fleets are involved.
Fleet 2 sweep
Fleet 3 sweep
Slip Time
Slip Time
Slip Time
Fleet 1 sweep
Slip Time
Slip Time
Fleet 1
Ready
Fleet 3
Ready
Fleet 2
Ready
Fleet 2
Ready
Fleet 3
Ready
T =time from
FO to TB
Fleet 1 sweep
T
T
T
T
T
Fleet 2 sweep
Operation
Slip-sweep > How to implement slip-sweep
336 428XL Users Manual Vol. 1
April 11, 2013
6
How to implement slip-sweep
1. To enable the Slip-sweep option see Seismic setup options on
page 281.
2. To set the Slip Time, see The Delay setup (page 295).
3. Use the The Acquisition Type setup (page 518) menu in the DPG
window to create an Acquisition Type (this determines which
type of sweep signal will be generated by the vibrator fleets).
4. Use the Process Type setup menu in the Operation main window
to create a Process Type for each fleet.
Figure 6-77
- You must use the Correlation Before Stack option.
- All the Process Types you want to use must include the same list
of auxiliary channels to acquire. In the example shown in
Figure 6-77, aux1 and aux2 should appear in each Process
Type to use. Process Type #1, is set to display aux1*aux1
(autocorrelation of aux1) on the third auxiliary trace; Process
Same list of auxiliary
channels in all
process types
Correlation operation
specific to this process
type
Same type for all
acquisitions to stack in
this process type
Stacking fold
Operation
Slip-sweep > How to implement slip-sweep
428XL Users Manual Vol. 1 337
April 11, 2013
6
Type #2, can be set to display aux2*aux2 (autocorrelation of
aux2) on the third auxiliary trace.
- In each Process Type, use a single Acquisition Type for all the
acquisitions to stack.
5. Use the The Source Point Setup (page 275) menu to create a list of
VPs and build an Operation Table. All VPs should use the same
spread (this is easy to achieve by creating a Superspread). Assign
one of the Process Types created at step 4 to each VP, for example
(see Figure 6-80):
VP11 Process Type 1
VP12 Process Type 2
VP13 Process Type 1
VP14 Process Type 2
VP15 Process Type 1, etc. .
6. Create a Source name and number for each vibrator fleet to use.
See Vibroseismic source parameters (page 291) for details. If you
choose Sequential as Moving option, choose the appropriate Step
(typically to be equal to the number of fleets used), depending on
how VPs are to be taken in sequence in your operation table.
Figure 6-78
7. Start each source by right-clicking on the first VP to do with it
(e.g. VP11 in the example shown in Figure 6-79) and choose the
appropriate source number from the Start Seismonitor with Vib
Sourcepopup menu (e. g. source #2).
Operation
Slip-sweep > How to implement slip-sweep
338 428XL Users Manual Vol. 1
April 11, 2013
6
Figure 6-79
Figure 6-80 Slip-Sweep with two sources
You will probably prefer to use the Navigation-driven shooting (page 309)
mode. To do that, you must use the Randomly Moving source type
option, rather than Sequential, and use the DSD Network (page 500)
option. In that case, Slip-Sweep shots are not necessarily taken in the
order defined in the Operation Table. Instead, the system automatically
selects the planned VP that matches the source location received from
Second VP11 acquisition starting with
Source #2 before first VP12 acquisition is
complete with Source #3
1st acq. done
Operation
Slip-sweep > Standard Slip-Sweep mode
428XL Users Manual Vol. 1 339
April 11, 2013
6
the next vibrator fleet leader that becomes ready (which sends the
Ready signal), regardless of which VP is next scheduled to get the focus
in the Operation Table.
Standard Slip-Sweep mode
In the examples shown in Figure 6-81 and Figure 6-82, each fleet can
start shaking right after the Slip Time has expired.
Figure 6-81 Slip-sweep with sequentially moving source, no stacking
Figure 6-82 Slip-sweep with sequentially moving source, stacking (2)
Fleet 1
F1 moving to
VP3 location
Fleet 2
VP1 (Acq1) VP3 (Acq1)
VP2 (Acq1) VP4 (Acq1)
VP5 (Acq1)
VP6 (Acq1)
Slip Time
Slip Time
F2 moving to
VP4 location
Slip Time
Slip Time
Slip Time
Slip Time
VP7 (Acq1)
Slip Time
Fleet 1
F1 moving to
VP3 location
Fleet 2
VP1 (Acq1) VP1 (Acq2)
VP2 (Acq1) VP2 (Acq2)
VP3 (Acq1)
VP4 (Acq1)
Slip Time
Slip Time
F2 moving to
VP4 location
Slip Time
Slip Time
Slip Time
Slip Time
VP3 (Acq2)
Slip Time
Operation
Slip-sweep > Standard Slip-Sweep mode
340 428XL Users Manual Vol. 1
April 11, 2013
6
In the example shown in Figure 6-83, each fleet can start shaking when
it is Ready and the Slip Time has expired and its COG matches a
planned source point to be done with that fleet (see VP Grabbing Radius
page 414), regardless of which VP is next scheduled to get the focus
in the Operation table.
Figure 6-83 Slip-sweep, randomly moving source, Navigation mode, no stacking
Slip Time
F1 moving to
VP6 location
F1
Ready
F2
Ready
F3
Ready
F2
Ready
F1
Ready
F3
Ready
F1
Ready
VP1 (Acq1)
Slip Time
Slip Time
Slip Time
Slip Time
Slip Time
VP2 (Acq1) VP4(Acq1)
VP6 (Acq1)
VP3 (Acq1) VP5 (Acq1)
F2 moving to
VP4 location
F3 moving to
VP5 location
Slip Time
VP6 (Acq1)
F1 moving to
VP8 location
Fleet 1
Fleet 2
Fleet 3
Operation
Slip-sweep > Standard Slip-Sweep mode
428XL Users Manual Vol. 1 341
April 11, 2013
6
In the example shown in Figure 6-84, you have to choose the Work by
Acq option for each source (see Vibroseismic source parameters
page 291). Each fleet can start shaking when it is Ready and the Slip
Time has expired and its COG matches a planned source point to be
done with that fleet (see VP Grabbing Radius page 414), regardless of
which VP is next scheduled to get the focus in the Operation table.
Figure 6-84 Slip-sweep with randomly moving source, Navigation mode, stacking (2)
Note To enable the system to open and suspend two or more VPs, see
428XL scalability (page 77).
Fleet 1
Fleet 2
VP1 (Acq1)
Slip Time
F1
Ready
Fleet 3
F1 moves to VP1 second
acquisition. location
Slip Time
VP1 (Acq2)
Slip Time
Slip Time
Slip Time
VP2 (Acq1) VP2 (Acq2)
VP3 (Acq1)
F3
Ready
F2
Ready
F1
Ready
F2
Ready
F3
Ready
Slip Time
VP4 (Acq1)
F2 moves to VP2 second
acquisition. location
Slip Time
VP3 (Acq2)
F1
Ready
Operation
Slip-sweep > Standard Slip-Sweep mode
342 428XL Users Manual Vol. 1
April 11, 2013
6
In the example shown in Figure 6-85, each fleet will start shaking when
it is Ready and the Slip Time has expired and its COG matches a
planned source point to be done with that fleet (see VP Grabbing Radius
page 414). Because acquisitions are stacked at the same place, the
fleet is implicitly Ready at the end of each sweep (unless this is the last
sweep within the VP), so it can shake as soon as the Slip Time has
expired.
Figure 6-85 Slip-sweep with randomly moving source, Navigation mode, stacking (2)
Fleet 1
Fleet 2
VP1 (Acq1)
Slip Time
F1 moving to
VP4 location
Implicit
Ready
Implicit
Ready
F1
Ready
Fleet 3
VP1 (Acq2)
Slip Time
VP2 (Acq1)
Slip Time
F3
Ready
F2
Ready
VP2 (Acq2)
Slip Time
VP3 (Acq1)
Slip Time
F1
Ready
VP3 (Acq2)
Slip Time
VP4 (Acq1)
Slip Time
Implicit
Ready
Operation
Slip-sweep > Allowable minimum distance between simultaneous sources
428XL Users Manual Vol. 1 343
April 11, 2013
6
Allowable minimum distance between simultaneous
sources
In Standard Slip-Sweep mode, you may want to let the system check
that, after a fleet has started shaking, no fleet is eligible to shake unless
it is far enough from the fleet currently shaking. The Check Min
Distance option in the Seismic Slip-Sweep (page 284) makes it
possible to specify how far two fleets should be apart for them to be
allowed to shake simultaneously.
For example, assuming the four fleets shown in Figure 6-86 and the
Check Min Distance is set to 80 m.
Figure 6-86
Note 1: In the above example, while F1 is shaking the system is notified
of F2 and F3 being ready,
- F2 is not eligible because the distance between F1 and F2 is less
than 80 m.
- F3 is eligible because it is far enough away (110 m) from F1. It
can start shaking after the Slip Time has expired.
Note 2: After the Slip Time for F3 has expired, F2 is ready, but not
eligible because it is less than 80 m from F1 which is still shaking.
10 m
1 2 3 4
F2 and F3 Ready
(Note 1)
Slip Time
Fleet 1
Slip Time
Fleet 3
100 m
F4 Ready
(Note 4)
Slip Time
Fleet 2
F3 sweep
F1 sweep
F2 sweep
Fleet 4
F4 sweep
100 m
(Note 2)
(Note 3)
F1 F2 F3 F4
Operation
Slip-sweep > Allowable minimum distance between simultaneous sources
344 428XL Users Manual Vol. 1
April 11, 2013
6
Note 3: After the F1 sweep is complete, F2 can start shaking as it is far
enough (100m) from F3.
Note 4: The system is notified of F4 being ready. F4 is eligible because
it is 200 m away from F2, but it will not be allowed to shake until the
Slip Time for F2 has expired.
For each fleet that is ready in the Active Source view, the Dist Min
column indicates its minimum distance from any fleet currently
shaking. Each row where that distance is greater than the specified
Check Min Distance is displayed in green (from light green for the
shortest separation to dark green for the longest one).
Figure 6-87
In progress
Eligible
Selected
Done
Too close
Operation
Slip-sweep > Dynamic Slip-Sweep mode
428XL Users Manual Vol. 1 345
April 11, 2013
6
Dynamic Slip-Sweep mode
The farther apart the fleets, the shorter the required Slip Time. Rather
than always using the same Slip Time, regardless of how far the fleets
are apart (that is the standard Slip-Sweep mode), you may want to use
the Dynamic Mode which allows you to specify different Slip Times
depending on the distance between fleets.
Figure 6-88 Delay setup in Dynamic Slip-sweep mode
By selecting the Dynamic Mode (page 285), you can create a table in the
The Delay setup (page 295) to enter different Slip Time setpoints for
different fleet separations.
After a fleet has started shaking, in order to determine which fleet is
next eligible to shake, the system interpolates between your Slip Time
setpoints and calculates the suitable Slip Time for the distance between
each fleet ready to shake and the fleet currently shaking. The system
automatically selects the fleet associated with the shortest Slip Time as
the one eligible to shake after this Slip Time has expired.
For example, in the chart below the slip time for a fleet separation of
500 m is calculated to be 3 s.
Operation
Slip-sweep > Dynamic Slip-Sweep mode
346 428XL Users Manual Vol. 1
April 11, 2013
6
Figure 6-89
Figure 6-90
300 m
1 2 3 4
F2 and F3 Ready
3 s
Fleet 1
9 s
Fleet 3
200 m
Fleet 4
F3 sweep
F1 sweep
F4 sweep
300 m
F1 F2 F3 F4
F4 Ready
Fleet 2
F2 sweep
3 s
Operation
Slip-sweep > Dynamic Slip-Sweep mode
428XL Users Manual Vol. 1 347
April 11, 2013
6
In the above example, the system is notified of F2 and F3 being ready
after F1 has started shaking, with F2 located 300 m from F1, and F3
located 500 m from F1. Therefore, F3 starts shaking after the calculated
Slip Time (3 s) has expired, because the Slip Time for F2 is longer (9 s).
When the system is notified of F4 being ready, the Slip Time for F2
(located 200 m from F3) is 12 s whereas the slip Time for F4 (located
300 m from F3) is shorter, therefore F4 starts shaking after its Slip Time
(9 s) has expired.
After F4 has started shaking, the Slip Time for F2 (located 500 m from
F4) is calculated to be 3 s. F2 can start shaking after this Slip Time has
expired.
Operation
SQC Dump mode > SQC Dump mode with VE464
348 428XL Users Manual Vol. 1
April 11, 2013
6
SQC Dump mode
Some vibratory seismic techniques require the recording of vibrator
motion signals on each vibrator. The 428XL allows the signals picked
up on the vibrators to be radioed to the central control unit in real-time
(as soon as each sweep is complete), using standard radio telemetry
units (LAUR), so that they can be recorded as auxiliary channels in the
SEGD file. To connect the necessary auxiliary channels, see Vibrator
signal recording (VSR) page 347 in 428XL Installation Manual.
With the SQC Dump mode enabled, the system will record only
uncorrelated (raw) data. An SEGD file containing the raw data is
generated and recorded for each individual acquisition for a shot point
(VP). Correlated data is only sent to the QC processing tool (eSQC-Pro)
for monitoring, but not recorded. The file supplied to eSQC-Pro has the
same file number as the raw data file for the last acquisition of the VP.
In this section:
SQC Dump mode with VE464 (page 348)
SQC Dump mode with VE432 (page 361)
SQC Dump mode with VE464
Below is a tutorial that will guide you through the process of setting up
the SQC Dump mode with the VE464.
1. In the Config window
Choose the Post Annotation Logging option in the Config windows
Crew setup. With a GPS receiver attached to each DSD, this allows the
position of each vibrator to be recorded in the Trace Header (Extension
block #2, bytes 1 through 20) of the auxiliary traces containing the
vibrator motion signals.
Operation
SQC Dump mode > SQC Dump mode with VE464
428XL Users Manual Vol. 1 349
April 11, 2013
6
2. In the VE464 window
Processing techniques making use of the vibrator motion signals
recorded require that you program the VE464 specifically, not to have
all the vibrators doing the same sweep. This is easily done with the
VE464, by creating a distinct fleet for each vibrator and having all fleets
(with the same Cluster number) shaking simultaneously.
For example, assuming you want to take four acquisitions for each shot
point, with four vibrators (therefore four fleets, each including a single
vibrator), and for each acquisition to stack, you want the initial phase of
each vibrator to be as in the table below:
Table 6-1 Textbook example
Acquisition Number
Vibrator number (= Fleet number)
1 2 3 4
1 0 90 180 -90
2 90 180 -90 0
3 180 -90 0 90
4 -90 0 90 180
Figure 6-91
Operation
SQC Dump mode > SQC Dump mode with VE464
350 428XL Users Manual Vol. 1
April 11, 2013
6
2.1 To implement this example, you need four basic signal types. Use
the Basic Type setup (see Figure 6-92 below) to create a Basic
signal type (e. g. linear1) with 0 phase shift.
- Create another one (linear2) with 90 phase shift, another one
(linear3) with 180 phase shift, and another one (linear4) with
-90 phase shift.
- For each signal type, tick the Numeric Pilot option.
Figure 6-92
Enter the desired
initial phase for each
signal type.
Operation
SQC Dump mode > SQC Dump mode with VE464
428XL Users Manual Vol. 1 351
April 11, 2013
6
2.2 Use the Acquisition Type setup window to create an Acquisition
Type for each acquisition to stack. For this example, you need four
Acquisition Types, each with four fleets.
Figure 6-93
For each Acquisition Type:
- Assign the appropriate Basic signal type to each fleet,
depending on the desired phase shift.
- In the Correl With field for each fleet, enter the Basic signal
type number to use as Numeric Pilot. In this example, let us
assume you want to record another pilot signal for each fleet. Its
Basic signal type number must be entered in the Add Pilot
field (see Figure 6-93 above).
1 1 1 2
2 2 2 3
3 3 3 4
4 4 4 1
1 1
2 1 2 3
3 2 3 4
4 3 4 1
1 4 1 2
2 2
3 1 3 4
4 2 4 1
1 3 1 2
2 4 2 3
3 3
4 1 4 1
1 2 1 2
2 3 2 3
3 4 3 4
4 4
Operation
SQC Dump mode > SQC Dump mode with VE464
352 428XL Users Manual Vol. 1
April 11, 2013
6
2.1 Use the Crew setup window to create vibrators and fleets (four
vibrators and four fleets for this example).
Figure 6-94
2.2 Use the Vibrator Fleet function to build the four fleets (in this
example, each fleet includes a single vibrator). Double-click on
the vibrator in each fleets list box to set is as Leader, and then
Click Go.
Figure 6-95
2.3 Click the Set DSD pushbutton in the control panel. In the list box
showing the DSDs that responded to the Vibrator Fleet function,
select the four vibrators you want to use, and then click Go.
Figure 6-96
Operation
SQC Dump mode > SQC Dump mode with VE464
428XL Users Manual Vol. 1 353
April 11, 2013
6
3. In the Line window
Open the Layout setup window and click on the the Auxiliary tab.
Figure 6-97
3.1 Choose the FDUs to use as auxiliary channels to convey signals
from DSDs (vibrator motion signals). Note that you can do that by
right-clicking on the desired FDUs in the topographic view and
selecting the Set Aux shortcut from the popup menu.
- For each of them, choose DSD from the Input from option
button.
- In the associated Device Nb field, enter the identification
number of the vibrator (DSD).
3.2 In this example, let us assume you want to record two more
auxiliary signals (Aux17 and Aux18) via two FDUs within a line
or connected to the LCI. For those auxiliary channels, choose
Spread from the Input from option button.
Note You will not be allowed to take sweeps unless all the auxiliary
channels you create in this setup are actually connected.
Vibrator 1 (Fleet 1)
Vibrator 2 (Fleet 2)
Vibrator 3 (Fleet 3)
Vibrator 4 (Fleet 4)
Any other auxiliary signal required,
from FDUs in the spread or
connected to the LCI
Operation
SQC Dump mode > SQC Dump mode with VE464
354 428XL Users Manual Vol. 1
April 11, 2013
6
4. In the Operation window
4.1 From the Seismic setup menu, choose SQC Dump. This
enables the recording of a raw data file for each acquisition. The
correlated data will be sent to eSQC-Pro but not recorded.
Figure 6-98
4.2 Use the Process Type setup window to create a Correlation
Before Stack process type.
Operation
SQC Dump mode > SQC Dump mode with VE464
428XL Users Manual Vol. 1 355
April 11, 2013
6
Figure 6-99
- Enter the description of auxiliary traces, for example an
auxiliary signal from the spread (aux17), autocorrelation of the
Numeric pilot signal of each fleet (correlWith*correlWith),
another auxiliary signal from the spread (aux18) and the
additional Numeric pilot for each source (addPilot).
- In the Correl with field, specify the reference signal
(correlWith) to use for the seismic channel correlation data
intended for eSQC-Pro.
- Choose the Append Auxes From DSD option. As a result, in
the SEGD file, the auxiliary traces containing the signals from
the DSDs will be recorded after those described in the Process
Type setup (see the example in Figure 6-103).
- In the Acquisition list box, create four acquisitions and choose
the dump option on the fourth. Assign the appropriate
Acquisition Type to each acquisition (for example Type 1 for
the 1st, Type 2 for the second, etc.).
4 acquisitions
For eSQC-Pro
This option enables
the recording of
vibrator motion signals
Numeric
pilots
Operation
SQC Dump mode > SQC Dump mode with VE464
356 428XL Users Manual Vol. 1
April 11, 2013
6
4.3 In the Source Type setup, create four sources and specify which
fleet to use for each source.
Figure 6-100
- Assign the same Cluster number to the four fleets. This will
allow the four sources to shake simultaneously.
- Set the Moving option as required. If you choose Sequential
then the Step should be equal to the number of sources (because
you are using simultaneous sources).
4.4 In the Source Shot setup window, a Shot (VP) number must be
created for each source point (this is typically done by loading
appropriate SPS files in the Log window). Assign the same
Process Type number to all source points.
Figure 6-101
4.5 In the main window, associate a shot point with each source, by
right-clicking in the All VP view (or in the Active Source
view) and slecting the Start Seismonitor with Vib Source#
shortcut (or Associate VP). If you are using the Navigation-
Same Cluster
Same
Process
Type
Operation
SQC Dump mode > SQC Dump mode with VE464
428XL Users Manual Vol. 1 357
April 11, 2013
6
driven shooting mode, you can choose any shot point since the
system will wait for the Ready message from each fleet to
determine which shot to do. Click Go.
Figure 6-102
The operator report (also available from the Log window) contains the
detailed indentification of the shot point (VP) and source points the
acquisition relates to. It includes one row for each source point. With
four acquisitions for each VP in this example, the observer report will
include 16 rows for each VP (4 source points 4 acquisitions).
5. In the Log window
An SPS S output file is available for each source point. With four source
points in this example, four SPS S files are generated for each
acquisition, and the SPS X output file includes four source points for the
same file number.
A source COG file is generated on the last acquisition of each VP.
For the format of those files, see Users Manual Vol. 2.
Simultaneous
sources
Operation
SQC Dump mode > SQC Dump mode with VE464
358 428XL Users Manual Vol. 1
April 11, 2013
6
6. In the SEGD file
The system generates an SEGD file with raw data for each acquisition.
The list order in the Process Type setup determines the order of
auxiliary traces in the SEGD file (see Figure 6-103). With the example
described above, the SEGD file will include 22 auxiliary traces.
Figure 6-103 Auxiliary traces recorded for the first acquisition
(A) Aux17 from FDU Serial No. 5491 in spread.
(B) Numeric Pilot for Fleet 1 (Basic signal Type 1).
(C) Aux18 from FDU Serial No. 5072 in spread.
(D) Additional Pilot for Fleet 1 (Basic signal Type 2).
(E) Appended signals from Vibrator1 (Fleet 1): ref1, plate1, etc.
1 FDU 5491
2 ve464 1
3 FDU 5072
4 ve464 2
5 FDU 5012
6 FDU 5562
7 FDU 5374
8 FDU 913
9 ve464 3
10 FDU 5674
11 FDU 5114
12 FDU 1192
13 FDU 5212
14 ve464 4
15 FDU 523
16 FDU 5293
17 FDU 5133
18 FDU 3574
19 FDU 3541
20 FDU 1021
21 FDU 5023
22 FDU 5474
1 1
1 1 1 2
2 2 2 3
3 3 3 4
4 4 4 1
(E)
(G)
(I)
(J )
SEGD Trace Header
(extract)
Aux Unit
trace Type S. N.
(F)
(H)
(A)
(B)
(C)
(D)
Operation
SQC Dump mode > SQC Dump mode with VE464
428XL Users Manual Vol. 1 359
April 11, 2013
6
(F) Additional Pilot for Fleet 2 (Basic signal Type 3). Note that the
Numeric Pilot for Fleet 2 (Basic signal Type 2) is not repeated
since it is already recorded in the 4th trace.
(G) Appended signals from Vibrator2 (Fleet 2): ref2, plate2, etc.
(H) Additional Pilot for Fleet 3 (Basic signal Type 4). Note that the
Numeric Pilot for Fleet 3 (Basic signal Type 3) is not repeated as
it is already recorded in the 9th trace.
(I) Appended signals from Vibrator3 (Fleet 3): ref3, plate3, etc.
(J ) Appended signals from Vibrator4 (Fleet 4): ref4, plate4, etc.
7. In the Positioning window
The Positioning window calculates and displays a source COG on the
last acquisition of each shot point (VP).
8. FPS files
For each acquisition, a File Per Source (FPS) file is generated in this
directory: workspace/result/log.
The FPS file includes vibrator attributes (much like a verbose APS file)
plus the SEGD file number. See Users Manual Vol. 2.
Operation
SQC Dump mode > SQC Dump mode with VE464
360 428XL Users Manual Vol. 1
April 11, 2013
6
9. In the eSQC-Pro window
Figure 6-104
After the last (fourth in this example) acquisition for a shot point (VP)
is complete, a file with correlated data is supplied to eSQC-Pro for
1 FDU 5491
2
3 FDU 5072
4
5 FDU 5012
6 FDU 5562
7 FDU 5374
8 FDU 913
9 FDU 5491
10
11 FDU 5072
12
13 FDU 5674
14 FDU 5114
15 FDU 1192
16 FDU 5212
17 FDU 5491
18
19 FDU 5072
20
21 FDU 523
22 FDU 5293
23 FDU 5133
24 FDU 3574
25 FDU 5491
26
27 FDU 5072
28
29 FDU 3541
30 FDU 1021
31 FDU 5023
32 FDU 5474
eSQC-Pro
Aux Unit
trace Type S. N.
(A)
Autocorrelation of Basic signal Type 2
(B)
Basic signal Type 3
(A)
(B)
Basic signal Type 4
(A)
Autocorrelation of Basic signal Type 4
(B)
Basic signal Type 1
Stacked signals from fleet1
Stacked signals from fleet2
Stacked signals from fleet3
Stacked signals from fleet4
Autocorrelation of Basic signal Type 3
Autocorrelation of Basic signal Type 1
(B)
(A)
Basic signal Type 2
Operation
SQC Dump mode > SQC Dump mode with VE432
428XL Users Manual Vol. 1 361
April 11, 2013
6
monitoring, but not recorded. With this example, it includes 32
auxiliary traces). On each VP, a single source is monitored, but the
correlation pilot is different, allowing all the sources to be monitored in
turn.
SQC Dump mode with VE432
Below is a tutorial that will guide you through the process of setting up
the SQC Dump mode with the VE432.
1. In the Config window
Choose the Post Annotation Logging option in the Config windows
Crew setup. With a GPS receiver attached to each DSD, this allows the
position of each vibrator to be recorded in the Trace Header (Extension
block #2, bytes 1 through 20) of the auxiliary traces containing the
vibrator motion signals.
Figure 6-105
2. In the VE432 window
Processing techniques making use of the vibrator motion signals
recorded require that you program the VE432 specifically, not to have
all the vibrators doing the same sweep within a vibrator group. This is
Operation
SQC Dump mode > SQC Dump mode with VE432
362 428XL Users Manual Vol. 1
April 11, 2013
6
easily done with the VE432, using the Custom (page 631) sweep type
option that allows each vibrator to generate a sweep loaded from a
PCMCIA card.
You only have to record replicas of a custom sweep, shifted as you like
(see Table 6-2) but identified with the same name, on as many PCMCIA
cards as required, then load each card to a DSD.
For example, assuming you wish to take four acquisitions on each shot
point (VP), with four vibrators, and the initial phase of each vibrator for
each acquisition to be as in the table below:
2.1 To implement this example, you have to create the following four
acquisition types in the Acquisition Type Setup window:
Acq #1: fleet #1: basic #1, Pilot signals: see Figure 6-
106
Acq #2: fleet #2: basic #2,
Acq #3: fleet #3: basic #3,
Acq #4: fleet #4 : basic #4,
Table 6-2 Textbook example
Acquisition Number
Vibrator
1 2 3 4
1 0 90 90 180
2 90 0 180 90
3 90 180 0 90
4 180 90 90 0
Operation
SQC Dump mode > SQC Dump mode with VE432
428XL Users Manual Vol. 1 363
April 11, 2013
6
Figure 6-106
2.2 Create the following four basic sweeps in the Basic Type Setup
window:
Figure 6-107
Basic#1: custom sweep#1
Basic#2: custom sweep#2
Basic#3: custom sweep#3
Basic#4: custom sweep#4
To record files to a PCMCIA card, see PCMCIA Tools (page 669).
On the PCMCIA for vibrator #1, store the following files:
Custom sweep #1: sweep initial phase: 0
Custom sweep #2: sweep initial phase: 90
1 1 1
1 1 1
2 2 2
3 3 3
4 4 4
2
2
3
4
1
3
4
1
2
4
1
2
3
3 4
1 Basic#1
custom sweep#1
1 Basic#1
2 Basic#2
3 Basic#3
4 Basic#4
Operation
SQC Dump mode > SQC Dump mode with VE432
364 428XL Users Manual Vol. 1
April 11, 2013
6
Custom sweep #3: sweep initial phase: 90
Custom sweep #4: sweep initial phase: 180
On the PCMCIA for vibrator #2, store the following files:
Custom sweep #1: sweep initial phase: 90
Custom sweep #2: sweep initial phase: 0
Custom sweep #3: sweep initial phase: 180
Custom sweep #4: sweep initial phase: 90
On the PCMCIA for vibrator #3, store the following files:
Custom sweep #1: sweep initial phase: 90
Custom sweep #2: sweep initial phase: 180
Custom sweep #3: sweep initial phase: 0
Custom sweep #4: sweep initial phase: 90
On the PCMCIA for vibrator #4, store the following files:
Custom sweep #1: sweep initial phase: 180
Custom sweep #2: sweep initial phase: 90
Custom sweep #3: sweep initial phase: 90
Custom sweep #4: sweep initial phase: 0
On the PCMCIA for the DPG , you can store the following files:
Custom sweep #1: sweep initial phase: 0
Custom sweep #2: sweep initial phase: 90
Custom sweep #3: sweep initial phase: 90
Custom sweep #4: sweep initial phase: 180
Operation
SQC Dump mode > SQC Dump mode with VE432
428XL Users Manual Vol. 1 365
April 11, 2013
6
3. In the Line window
Open the Layout setup window and click on the the Auxiliary tab.
Figure 6-108
3.1 Choose the FDUs to use as auxiliary channels to convey signals
from DSDs (vibrator motion signals). Note that you can do that by
right-clicking on the desired FDUs in the topographic view and
selecting the Set Aux shortcut from the popup menu.
- For each of them, choose DSD from the Input from option
button.
- In the associated Device Nb field, enter the identification
number of the vibrator (DSD).
3.2 In this example, let us assume you want to record four analog pilot
signals (Pilot1, Pilot2, Pilot3, Pilot4) from the DPG via two FDUs
connected to the LCI. For those auxiliary channels, choose
Spread from the Input from option button.
Vibrator 1
Analog pilots from DPG via FDUs
connected to the LCI
Pilot1
Pilot2
Vibrator 2
Vibrator 3
Vibrator 4
Pilot3
Pilot4
Operation
SQC Dump mode > SQC Dump mode with VE432
366 428XL Users Manual Vol. 1
April 11, 2013
6
Note You will not be allowed to take sweeps unless all the auxiliary
channels you create in this setup are actually connected.
4. In the Operation window
4.1 From the Seismic setup menu, choose SQC
Dump. This enables the recording of a raw
data file for each acquisition. The correlated
data will be sent to eSQC-Pro but not
recorded.
4.2 In the Process Type setup, create a
Correlation Before Stack process type and
choose the Rawoption to record the raw
data.
Figure 6-110
Figure 6-109
4 acquisitions
This option enables
the recording of
vibrator motion signals
For eSQC-Pro
Pilot1
Pilot1
Pilot2
Pilot3
Pilot1
Pilot4
ta1
ta2
ta3
ta4
Operation
SQC Dump mode > SQC Dump mode with VE432
428XL Users Manual Vol. 1 367
April 11, 2013
6
- Enter the description of auxiliary traces: a trace for the Pilot1
signal, another trace for the Pilot2 signal, etc.
- In the Correl with field, specify the reference signal (Pilot1)
to use for the seismic channel correlation data intended for
eSQC-Pro.
- Choose the Append Auxes From DSD option. As a result, in
the SEGD file, the auxiliary traces containing the signals from
the DSDs will be recorded after those described in the Process
Type setup.
- In the Acquisition list box, create four acquisitions and choose
the dump option on the fourth. Assign the appropriate
Acquisition Type to each acquisition (for example Type 1 for
the 1st, Type 2 for the second, etc.).
4.3 In Source Type setup, create a source and specify which fleet to
use.
Figure 6-111
4.4 In the Source Shot setup window, a Shot (VP) number must be
created for each source point (this is typically done by loading
appropriate SPS files in the Log window). Assign the same
Process Type number to all source points.
Operation
SQC Dump mode > SQC Dump mode with VE432
368 428XL Users Manual Vol. 1
April 11, 2013
6
Figure 6-112
4.5 In the main window, associate a shot point with the source, by
right-clicking in the All VP view (or in the Active Source
view) and slecting the Start Seismonitor with Vib Source#
shortcut (or Associate VP). If you are using the Navigation-
driven shooting mode, you can choose any shot point since the
system will wait for the Ready message from the fleet to
determine which shot to do. Click Go.
The operator report (also available from the Log window) contains the
detailed indentification of the source point the acquisition relates to. It
includes one row for each acquisition. In this example, the observer
report will include 4 rows for each shot point.
5. In the Log window
An SPS S output file is generated on each acquisition.
A source COG file is generated on the last acquisition of each VP.
For the format of those files, see Users Manual Vol. 2.
Same
Process
Type
Operation
SQC Dump mode > SQC Dump mode with VE432
428XL Users Manual Vol. 1 369
April 11, 2013
6
6. In the SEGD file
The system generates an SEGD file with raw data for each acquisition.
The list order in the Process Type setup determines the order of
auxiliary traces in the SEGD file (see Figure 6-103). With the example
described above, the SEGD file will include 20 auxiliary traces.
Figure 6-113 Auxiliary traces recorded for the first acquisition
(A) Pilot1 from FDU Serial No. 5491.
(B) Pilot2 from FDU Serial No. 5072.
(C) Pilot3 from FDU Serial No. 3523.
(D) Pilot4 from FDU Serial No. 2147.
(E) Appended signals from Vibrator1: ref1, plate1, etc.
(F) Appended signals from Vibrator2: ref2, plate2, etc.
1 FDU 5491
2 FDU 5072
3 FDU 3523
4 FDU 2147
5 FDU 5012
6 FDU 5562
7 FDU 5374
8 FDU 913
9 FDU 5674
10 FDU 5114
11 FDU 1192
12 FDU 5212
13 FDU 523
14 FDU 5293
15 FDU 5133
16 FDU 3574
17 FDU 3541
18 FDU 1021
19 FDU 5023
20 FDU 5474
(A)
(B)
(C)
(E)
SEGD Trace Header
(extract)
Aux Unit
trace Type S. N.
Pilot1
Pilot1
Pilot2
Pilot3
Pilot1
Pilot2
Pilot1
ta1
Pilot4
ta2
ta3
ta4
Pilot3
Pilot4
(D)
(F)
(G)
(H)
Operation
SQC Dump mode > SQC Dump mode with VE432
370 428XL Users Manual Vol. 1
April 11, 2013
6
(G) Appended signals from Vibrator3: ref3, plate3, etc.
(H) Appended signals from Vibrator4: ref4, plate4, etc.
7. In the Positioning window
In the FPS layer in the Positioning window a circle is displayed around
the planned position of each vibrator, and a smaller circle filled with
green is displayed for the actual position.
8. FPS files
For each acquisition, a File Per Source (FPS) file is generated in this
directory: workspace/result/log.
The FPS file includes vibrator attributes (much like a verbose APS file)
plus the SEGD file number. See Users Manual Vol. 2.
9. In the eSQC-Pro window
After the last (fourth in this example) acquisition for a shot point (VP)
is complete, a file with correlated data is supplied to eSQC-Pro for
monitoring, but not recorded. With this example, it includes 32
auxiliary traces.
Operation
Micro-seismic >
428XL Users Manual Vol. 1 371
April 11, 2013
6
Micro-seismic
Selecting the Micro-seismic option in the Seismic setup options
(page 281) window allows the system to do a continuous acquisition
from a fixed spread with no source (passive listening). For example, this
operating mode can be used in shallow-water operations.
Figure 6-114
If you are using an LCI as control unit, the FO signal (pin T) on its
Blaster port must be wired to the TB signal (pinK) using the Blaster
plug provided. Also, pin L must be wired to ground (pin R). The
precision of the built-in clock can be increased by using the PPS
signal from a GPS receiver, connected via the XDEV2 port of the
LCI. In that case, you have to choose the GPS Time Management
(page 90) option in the Configuration windows Crew setup.
If you are using a 428-Lite box as control unit, an external Time
Break is required. The acquisition length must be set to be equal to
(or a multiple of) the recurrence rate of the Time Break.
To launch the acquisition, simply click Go. The continuous acquisition
consists of consecutive shots with zero dead-time. No sample is lost
between the last sample in a shot and the first sample in the next one.
As the Spread never changes, a single Process Type is used and a single
row is required in the operation table. After each shot is completed, the
File Number is automatically incremented and an operator report is
generated. The Point Index and Shot Number are not incremented.
Operation
Micro-seismic >
372 428XL Users Manual Vol. 1
April 11, 2013
6
With the Line Error Recovery option activated, the system
automatically goes to Field Off, then Field On if an error arises (this
resets the field electronics). Acquisition resumes as the system goes to
Field On, regardless of whether or not any dead traces are present.
Offset removal is disabled (this is notified by recording 1 in bytes
873-876 in the SEGD files Extended Header).
Operation
Autonomous mode >
428XL Users Manual Vol. 1 373
April 11, 2013
6
Autonomous mode
Introduction
The Autonomous mode allows simultaneous-source shooting with
sweeps being launched independently. As soon as all vibrators in a fleet
are ready (pads down) at the planned locations, the operator pressing the
Ready button on the Leader DSD starts a sweep on all DSDs without
caring about synchronization with the recording truck. The planned
Vibrator Points can be done in any order.
The interest of using the Autonomous mode is to eliminate the need for
radio communications for starting the sweeps, which makes it
especially suited to difficult radio environments. A radio link is still
required, however, but only for the status messages from the vibrators
to the GUI, which can be transmitted during intervals with good radio
conditions.
The recording unit is set to perform a continuous acquisition consisting
of consecutive shots with zero dead-time. No sample is lost between the
last sample from a shot and the first sample from the next one (like in
Micro-seismic mode).
Note that unless it is attached to a fleet, an Autonomous DSD behaves
like any DSD in Local mode (same as after pressing the Local
button on the DSD).
Requirements
This mode of operation requires special seismic data processing
techniques.
On the Blaster port of the LCI, the FO signal (pin T) must be wired to
the TB signal (pin K) using the Blaster plug provided. Also, pin L must
be wired to ground (pin R).
The LCI must be attached to a GPS receiver so that the seismic samples
can be accurately time-stamped, and each DSD must be set to save the
Force signal locally. Also, each vibrator must use a GPS receiver.
Operation
Autonomous mode >
374 428XL Users Manual Vol. 1
April 11, 2013
6
Unless a fleet consists of a single vibrator, it must use a WIFI network.
The Autonomous mode neither requires nor allows the use of the
Vibrator Guidance function.
How to use the Autonomous mode
1. On a PC computer, use the VE464 VLI interface to set each DSD
to the Autonomous mode (DSD Setup menu), and enable the
Force local archive option (Options Setup menu).
Figure 6-115 VLI setup
2. Use the 428XL GUI to enable the Autonomous mode. To do that,
you have to select that option in the Operating Mode (page 281)
setup in the Operation window, then notify the DPG by going to
Auto in the VE464 DPG window (if the DPG is already in Auto
mode, go to Manual then Auto).
3. Create a Vibroseismic Stack (page 272) Process Type with a single
acquisition (this allows recording uncorrelated, unstacked data).
In the Source Type setup, choose the Sequential Moving option
(See Vibroseismic source parameters page 291).
4. Load SPS files, using the Log window, to populate The Source
Point Setup (page 275) and the Positioning window.
5. Switch all DSDs to the Remote mode (press the Remote
button on the DSD).
Operation
Autonomous mode >
428XL Users Manual Vol. 1 375
April 11, 2013
6
6. For this step, the radio link must be available so that the following
functions can be done, in the VE464 window:
- Set Vib Fleet to assign DSDs to fleets. Note that unless a fleet
consists of a single vibrator, it must use a WIFI network. Set the
DSD network option accordingly in The Vibrator Crew setup
(page 498).
- Set DSD to upload sweep-type parameters to the DSDs, and also
the description of the source pattern.
- Set Servo to set the servo control loop parameters in the DSDs;
- and any other function that may be necessary (Get DSD, etc.).
7. Once the DSDs are assigned to fleets and ready to sweep, switch
all DSDs to the Local mode (Local button on the DSD).
8. In the Operation table, select a VP with the Process Type created
in step 3, and click Go to start the continuous acquisition. After
each shot is completed, the File Number is automatically
incremented and an operator report is generated. The Point Index
and Shot Number are not incremented.
9. When the vibrator pad is down after pressing the Down button,
and the pressure sensor switch, if used, says the pad is down at
the planned source location, pressing the Ready pushbutton on the
DSD starts a sweep as follows:
- With no WIFI network (a single vibrator in each fleet), pressing
the Ready pushbutton launches a local sweep.
- With a WIFI network, when all vibrators in the fleet have their
pads down (and the Leader DSD is notified by WIFI of all
pressure switches saying all pads are down), pressing the Ready
pushbutton on the Leader DSD launches a sweep on all the
vibrators. As all the DSDs in the fleet are synchronized with the
Leader, they start sweeping at the same time. This is the
recommended way of using the Autonomous mode.
10. After completing a sweep the DSD tries to send a status message
to the recording truck, via the radio link with the DPG, until it is
Operation
Autonomous mode >
376 428XL Users Manual Vol. 1
April 11, 2013
6
notified of the status being actually received by the DPG. If, for
any reason, the radio path is obstructed for some time, the status
message and the next ones are stored in the DSD and, when the
radio link is available again, they are sent to the DPG in the order
of their occurrence.
11. The VE464 and Positioning windows are updated with the sweep
status messages received, which makes it easy for the operator to
see which shots are done and see if any sweep failed.
The system uses the $GPGGA GPS information from the status
message to find the nearest source point and calculate the COG to
display it in the Positioning window. See Figure 6-116 (page 376) and
Figure 6-117 (page 377) below.
Figure 6-116 VE464 window
Operation
Autonomous mode >
428XL Users Manual Vol. 1 377
April 11, 2013
6
The Vp and Acq# columns in the VE464 windows numeric view
are irrelevant, and therefore dimmed. As usual, double-clicking in any
cell opens a secondary window showing the detailed QC values
contained in the status report from the corresponding DSD. This also
causes a sprite to appear in the Positioning window, indicating the
geographical position of the DSD during the sweep.
Selecting Get Properties from the right-click menu on the sprite
causes a Properties window to pop up, containing the Vibrator number,
the status code and the actual position of the vibrator during the sweep.
See Figure 6-117 (page 377).
Figure 6-117 Positioning window
Note that you can look for more information in the APS and APS
Verbose file available from the LOG. window.
Operation
Vibrator Guidance > How to use the Vibrator Guidance option
378 428XL Users Manual Vol. 1
April 11, 2013
6
Vibrator Guidance
The VE432 or VE464 Guidance option allows each vibrator in a fleet to
be steered to the next location where it is expected to shake: the 428XL
GUI transmits the shake locations to the DPG, which relays them to
each DSD in the fleet. A graphic interface mounted on the vibrator
trucks dashboard helps the driver steer the vibrator to the next shake
location.
In this section:
How to use the Vibrator Guidance option (page 378)
The Go To Waypoint command (page 379)
How to use the Vibrator Guidance option
1. Make sure the Tablet PC is connected to the DSD in each vibrator
truck. See the VE464 Users Manual for details.
2. In the Operation windows Operating Mode (page 281) Setup,
choose the Guidance option and supply the central latitude of the
spread.
3. In the Positioning window, use the Geodetic setup menu to select
the appropriate Datum and Projection. Click Apply.
4. In the VE432 or VE464 windows Pattern Setup, define the
necessary vibrator patterns. A Pattern description specifies the
position of each vibrator with respect to the Centre Of Gravity of a
Source Point. See The Pattern setup window (page 532).
5. Use the VE432 or VE464 windows Vib Fleet button to assign a
DSD, hence a vibrator, to each point in the pattern, for each fleet.
See Vibrator Fleet (page 537). Unless the number of vibrators in
each fleet is consistent with the Pattern setup, the system will not
let you take any sweep. Then, use the Set Guidance function to
transmit patterns, Datum and projection parameters to the DSDs.
6. Be sure a vibrator pattern is assigned to each VP in the Operation
windows The Source Point Setup (page 275).
Operation
Vibrator Guidance > The Go To Waypoint command
428XL Users Manual Vol. 1 379
April 11, 2013
6
7. Set the VE432 or VE464 window to the Auto mode;
8. In the Operation windows Active Source view, right-click on
source and choose Go To Waypoint. In the box that pops up,
enter the VP number of the first source point to be done by the
vibrator fleet. Click the Go To button. (Subsequently, the location
of the next VP will be radioed to each DSD together with the
command to do a VP). See page 379.
9. Still in the Operation window, click Go to take the first sweep.
Each DSD receives the position of the next VP.
10. After a VP is completed, each driver uses the guidance display
tool to steer the vibrator to the next shake location, depending on
its position within the pattern associated with the VP.
11. When all vibrators in the fleet are ready at the shake location, the
sweep can be taken (if the Navigation option is used, the Ready
code from each vibrator allows the VP to be done automatically).
The Go To Waypoint command
In the Operation windows Active Source view, right-clicking on a
source and choosing Go To Waypoint opens a box that is typically used
to specify the VP number of the first source point to be done by the
associated vibrator fleets DSDs.
Figure 6-118
Clicking Go To causes the system to transmit the latitude and longitude
of that source point to the DSDs. Note that this can also be done by
dragging and dropping a fleets icon to a source point in the jPositioning
window.
This command can also be used to redirect a fleet back to a VP that was
not done properly. Subsequently, the position of the next VP is
Operation
Vibrator Guidance > The Go To Waypoint command
380 428XL Users Manual Vol. 1
April 11, 2013
6
contained in the T0_Data code radioed to each DSD to launch a sweep
(see Note below).
You can use the Go To Waypoint right-click menu on several sources
in the Active Source view to steer the associated fleets to different
source points, without interrupting the acquisition cycle (for example,
you can redirect one fleet while another one is shaking).
Operation
Multi-gun Shallow-water shooting mode >
428XL Users Manual Vol. 1 381
April 11, 2013
6
Multi-gun Shallow-water shooting mode
Figure 6-119
1. Choose Shallow in the Operation windows Seismic setup options
(page 281). This sets the system to the continuous acquisition
mode. In the Operation main window, choose the first SP to shoot
(this starts seismonitor).
2. The first Air Gun controller generates the External Go (EGO)
signal. This causes the LCI to wait for a Time Break (TB) signal.
(It will keep waiting for the TB endlessly unless you click on
Stop).
3. The first Air Gun controller generates the TB at least 1 second
after its External Go. This starts acquisition.
4. The first Air Gun controller transmits its source status (SPS)
message during acquisition.
5. The "Ready" message from the second Air Gun controller can be
transmitted during or after the acquisition.
6. After the acquisition is complete, the second Air gun controller
generates the External Go (EGO) signal, at least 2 seconds
after transmitting its Ready message. This causes the LCI to
wait for a Time Break (TB) signal from the second Air Gun
Acquisition1
LCI
Air Gun 2
Air Gun 1
Observer
EGO1
Waiting
for TB
(1 s min.)
TB1 SPS1
Ready2
(2 s min.)
EGO2
Acquisition2
Waiting
for TB
(1 s min.)
TB2 SPS2
Ready1
1 2 3 4 5 6 7
(See description of
each step below)
Operation
Multi-gun Shallow-water shooting mode >
382 428XL Users Manual Vol. 1
April 11, 2013
6
controller. (It will keep waiting for the TB endlessly unless you
click on Stop).
7. The second Air Gun controller generates the TB at least 1 second
after its External Go. This starts acquisition, and so on and so
forth.
All air gun controllers must be connected to the same Blaster connector
on the LCI (see Connectors and cables in 428XL Installation
Manual). See also Source controller interfacing in 428XL Users
Manual Vol. 3.
Figure 6-120
The source (SPS) message must be transmitted before the Ready
message. The Ready message can be transmitted during or after
acquisition.
In the Active Source view, the Rdy pushbutton must be depressed.
This causes the content of the Ready message (future position of gun
boat) to be automatically accepted to select the next shot to do from the
operation table. As a result, the source point information from the
Ready message overrides the continuous progress scheduled in the list
of shots to do.
Figure 6-121
Air Gun
controller 1
Air Gun
controller 2
Air Gun
controller 3
Operation
Multi-gun Shallow-water shooting mode >
428XL Users Manual Vol. 1 383
April 11, 2013
6
If the Rdy pushbutton is released, then the next shot to do is selected
as scheduled in the operation table, in steps determined by in the
Increment parameter from the Source Type Setup (see Explosive
source parameters page 290).
Ready Message
*AIRGUN SEQ#xx,SPLyyyyyyyy.yy,SPNzzzzzzzz.zz<CR><LF>
xx: AirGun Number
yyyyyyyy.yy: Source Point Line
zzzzzzzz.zz: Source Point Number
<CR>: Carriage Return
<LF>: Line Feed
Spread
All acquisitions must be done with the same Superspread. No change to
the Superspread is allowed.
The active spread can be changed between acquisitions.
Operation
Master/Slave operation >
384 428XL Users Manual Vol. 1
April 11, 2013
6
Master/Slave operation
The Master/Slave mode allows using up to four separate 428XL
systems synchronized to a Master 428XL. For details on cabling, see
Master/Slave configuration (page 66) in the 428XL Installation Manual.
To enable the use of a Master/Slave configuration, you must select the
Master option in the jInstall window on the Master system (in the
Master/Slave (page 79) tab), and on each Slave system you must select
the Slave option in the jInstall window. As a result, a Master Enable /
Master Disable button is available in the jOperation window of the
Master system, and a Slave Enable / Slave Disable button is available
on each Slave system.
On each Slave system:
The SPS S, R and X files loaded into the Slave systems must be
consistent with those loaded into the Master system.
Use the same Operation parameter settings (Process Type, Source
Point) as the Master system.
In the jConfig window, use the same parameter settings (Sample
Rate, Filter, etc.) as on the Master system, except for the Swath setup.
Click on On Line as usual.
In the jLine window, use all setup menus as usual and click on Field
On to look for the channels attached to the system.
jOperation window on the Master system
By default, the Master process is disabled and the Master 428XL can
be used as a standalone system unless and until the operator clicks on
the Master Enable button in the jOperation window.
Operation
Master/Slave operation >
428XL Users Manual Vol. 1 385
April 11, 2013
6
Figure 6-122 Master systems jOperation window
Once the operator has selected Master Enable,
the Master system waits until all Slave systems are ready to shoot, and
controls everything to ensure the TB on each Slave system is
synchronized. If any Slave system is not ready, or if there is a problem
with the parameters of the Master system, no shot or sweep can be
launched.
On the Master system, the selection of the Shot or VP to do and the
source to use is done as usual, and the Go and Stop buttons in the Active
Source view work the same way as with a standalone system, i. e.
depending on which Automation option (Continuous/Discontinuous/
Manual) is selected in the Seismic Setup. The Abort button is not
available.
If a shot or sweep is launched but acquisition does not complete
normally on a Slave system (for example because it failed to receive the
TB), the Master system stops the acquisition cycle. Then the operator
can cancel the Shot or VP and select the next one to do.
Operation
Master/Slave operation >
386 428XL Users Manual Vol. 1
April 11, 2013
6
In order to cancel or end a VP in Continuous mode, the operator has
to click on Stop on the Master system. The Cancelor End command
from the Master system is applied to the Slave systems automatically.
Note that when the operator clicks on a Shot or VP in the operation
table, this not only starts the Seismonitor function in the Master
systems Line window, but also causes each slave system to receive a
command to start Seismonitor on its own spread which allows
looking at the spread prior to doing a shot or VP.
jOperation window on a Slave system
By default, the Slave process is disabled and the Slave 428XL can be
used as a standalone system unless and until the operator clicks on the
Slave Enable button in the jOperation window of the Slave system.
Figure 6-123 Slave systems jOperation window
Once the operator has selected Slave Enable,
only the Slave Disable button remains available. All other commands
are unavailable, and shooting is totally controlled by the Master system.
The Automation option (Continuous/Discontinuous/ Manual) in the
Seismic Setup is ignored.
Unavailable
Operation
Master/Slave operation >
428XL Users Manual Vol. 1 387
April 11, 2013
6
If anything goes wrong on the Slave system (for example dead traces or
missing auxiliary traces), an error is reported in the jOperation window
of the Master system, or no shot is launched.
jExport window
On each system, use the jExport window as usual (on each shot, each
system generates an SEGD file for the traces from its own spread).
Operation
More About Noise Elimination > Spike Editing method
388 428XL Users Manual Vol. 1
April 11, 2013
6
More About Noise Elimination
In this section:
Spike Editing method (page 388)
Diversity Stack (page 391)
Spike Editing method
The Spike Editing method removes all samples exceeding a special
threshold.
The traces are processed successively in the order generated by the
acquisition process. Acquisition is performed line by line (from Low to
High receiver positions), starting with the farthest Left line.
The first trace is therefore the farthest in the Low branch, in the farthest
Left line.
When the number of traces increases (roll in), the new traces are
initialized with the value of the Threshold Init Value parameter.
When the number of traces decreases (roll out) it is the last ones which
disappear.
Each trace is divided into several time windows whose length is equal
to Acquisition Length/Nb of Windows.
The maximum number of windows for each trace is 64.
Each window has its own threshold, expressed as a multiple of 3 dB.
Every acquisition with the same length and energy spreading can be
associated with the same threshold type (i.e. if the initial phase only is
different). If acquisition types with different lengths or energy levels are
used, they must be associated with different threshold types.
There may be up to 16 different threshold types.
Two aspects are to be considered in the processing of a trace: removal
of samples exceeding a threshold, and threshold updating.
Operation
More About Noise Elimination > Spike Editing method
428XL Users Manual Vol. 1 389
April 11, 2013
6
Removal of samples exceeding a threshold
Two methods can be used:
Zeroing
With this method, any sample greater than or equal to the threshold
causes a number of samples to be zeroed.
The number of zeroed samples is specified by Zeroing Length, and
the zeroing process is brought in and removed gradually, i.e. beginning
and ending with a linear-variation taper.
The Taper Length is expressed as a number of samples and equal to a
power of 2.
Clipping
Any sample exceeding the threshold is cut down to the value of the
threshold.
Threshold updating
In each window, the threshold is updated with respect to the highest
sample in the window.
Threshold updating is performed at the end of the noise elimination
process, using the Range parameter (12 dB) as follows (see also
Figure 6-124 on page 390):
Highest sample within D area:
If Threshold-3dB-Range >Highest sample, then Threshold is decreased
3dB.
Highest sample within C area:
If Thresh -3dB >Highest sample > Thresh-3dB-Range, then Threshold
is unchanged.
Highest sample within B area:
If Threshold >Highest sample > Threshold-3dB, then Threshold is
increased 3 dB.
Operation
More About Noise Elimination > Spike Editing method
390 428XL Users Manual Vol. 1
April 11, 2013
6
Highest sample within A area:
If Highest sample >Thresh and VP's 1st acquisition complete, then
Threshold is increased 3 dB.
Figure 6-124
Special cases
Threshold updating is not performed:
- if the trace is reported Low,
- if the Hold option is selected, rather than Var. (variable),
- if the trace is dead (corrupted).
A trace is Low if, before noise elimination, the percentage of samples
which are smaller than the specified Low Trace Value exceeds the
specified Low Trace %.

A A A A
Thr.
3 dB

(12 dB)
-3 dB
B B B B
C C C C
D D D D
Thr.-3dB
>max sample
>Thr-3 dB-Range
Thr unchanged
Thr.-3dB-Range
>max sample
Thr = Thr-3 dB
Thr>max sample
> Thr.-3dB
Thr = Thr+3 dB
max sample >Thr.
Thr = Thr+3 dB
Range
Operation
More About Noise Elimination > Diversity Stack
428XL Users Manual Vol. 1 391
April 11, 2013
6
Diversity Stack
The Diversity Stack method is only used with Correlation After
Stack process types.
Each trace is divided into several time windows whose length equals:
The maximum number of windows for each trace is 64.
The entire processing is performed before correlation but includes two
parts: before stacking and after stacking.
A(k) =kth sample
n =number of samples in the window
i =trace index
j =window index
p =current stack fold
Processing before stack
For each time window in a trace, the energy is calculated:
On the first window, the following is calculated:
On the subsequent windows, a ramp is applied to the samples:
AcquisitionLength
NumberOfWindows
----------------------------------------------------
| |
E i j p
A k
n
k
n
( , , )
( )
=
=

2
1
A k ( )*
1
E i j p , , ( )
---------------------
Operation
More About Noise Elimination > Diversity Stack
392 428XL Users Manual Vol. 1
April 11, 2013
6
Computation of the ramp increment (S) for a window:
Processing on the samples:
Assuming the current stack fold is p, when the whole ith trace is
computed the following computation is performed on all the E(i,j,p)
terms for each window:
Processing after stack
Assuming m is the last stacking fold prior to writing to the SEGD file,
the following computation is performed:
On the first window, the following computation is performed:
On the subsequent windows, a ramp is applied to the samples:
Computation of the ramp increment (S) for a window:
S j ( )
E i j p , , ( ) E i j 1 p , , ( )
n
--------------------------------------------------------- =
A k ( )
E i j 1 p , , ( ) S j ( )*k +
---------------------------------------------------- where (1 s k s n).
1
E i j p , , ( )
---------------------
1
E i j p 1 , , ( )
------------------------------ +
A k
E i j p
p
m
( )
( , , )
-
=

1
1
1
S j
E i j p E i j p
n
p
m
p
m
( )
( , , ) ( , , )
=

= =

1
1
1
1
1
1 1
Operation
More About Noise Elimination > Enhanced Diversity
428XL Users Manual Vol. 1 393
April 11, 2013
6
Processing on the samples:
where (1 s k s n).
See also More About Correlation (page 396).
Enhanced Diversity
The Enhanced Diversity method is only used with Correlation After
Stack process types.
Each trace is divided into a number of time windows, determined by the
specified Window Length:
The start time of each window is calculated to achieve the specified
Overlap Percent, which determines the total number of windows.
The entire processing is performed before correlation but includes two
parts: before stacking and after stacking.
A(k) =kth sample
n =number of samples in the window
i =trace index
j =window index
p =current stack fold
| |
A k
E i j p
S j k
P
m
( )
( , , )
( ) -

+ -

(
(
(
(
=

1
1
1
1
Number of windows
Acquisition Length
Window Length
---------------------------------------------- =
Operation
More About Noise Elimination > Enhanced Diversity
394 428XL Users Manual Vol. 1
April 11, 2013
6
Processing before stack
For each time window in a trace, the energy is calculated:
Except for the first and last windows, a ramp is applied to the samples
in each window. The ramp spans from the midpoint of each window to
the midpoint of the next, as shown below.
Figure 6-125
The samples before the first window midpoint and those after the last
are processed as follows:
The samples in between are processed as follows:
- Computation of the ramp increment (S) for a window:
- Processing:
| |
E i j p
A k
n
k
n
( , , )
( )
=
=

2
1
E1
E2
Overlap
j=1
j=2
1st
window midpoint
Last
window midpoint
A k ( )
E i j p , , ( )
---------------------
S j ( )
E i j p , , ( ) E i j 1 p , , ( )
n
--------------------------------------------------------- =
A k ( )
E i j 1 p , , ( ) S j ( )*k +
---------------------------------------------------- where (1 s k s n).
Operation
More About Noise Elimination > Enhanced Diversity
428XL Users Manual Vol. 1 395
April 11, 2013
6
Assuming the current stack fold is p, when the whole ith trace is
computed the following computation is performed on all the E(i,j,p)
terms for each window:
Processing after stack
Assuming m is the last stacking fold prior to writing to the SEGD file,
a ramp is applied to the samples in each window (except for the first and
last windows). The ramp spans from the midpoint of each window to the
midpoint of the next.
The samples before the first window midpoint and those after the last
are processed as follows:
The samples in between are processed as follows:
- Computation of the ramp increment (S) for a window:
- Processing:
where (1 s k s n).
See also More About Correlation (page 396).
1
E i j p , , ( )
---------------------
1
E i j p 1 , , ( )
------------------------------ +
A k ( )
1
E i j p , , ( )
---------------------
p 1 =
m

------------------------------------
S j ( )
1
E i j p , , ( )
---------------------
p 1 =
m

1
E i j 1 p , , ( )
------------------------------
p 1 =
m

n
---------------------------------------------------------------------------------- =
A k ( )
1
E i j 1 p , , ( )
------------------------------
p 1 =
m

S j ( ) * k | | +
-------------------------------------------------------------------------------
Operation
More About Correlation > Description
396 428XL Users Manual Vol. 1
April 11, 2013
6
More About Correlation
In this section:
Description (page 396)
Data Distribution (page 398)
Description
Correlation is achieved in the frequency domain, using the Fast Fourier
Transform method. It is performed on a set of data whose length is 2
n
,
greater than Pilot length or Sweep length, whichever is the longest,
+Investigation length.
Correlation can be performed on auxiliary traces and seismic traces.
Each trace is correlated as a real vector. The results from the correlation
process begin with positive time result data and end with negative time
result data.
Correlation of auxiliary traces
The following operations are allowed on an auxiliary trace:
Autocorrelation (e.g. aux1*aux1)
Cross-correlation (e.g. aux2*aux1)
Stack (e.g. aux3)
For Autocorrelation or Cross-correlation, the second term in the
expression of the correlation operation stands for the reference wavelet.
Autocorrelation and cross-correlation
Autocorrelation and crosscorrelation processings are identical. Each
correlated trace is recorded on a single trace (either the positive or
negative time side, whichever is specified in the description of the
Auxiliary traces page 263).
Operation
More About Correlation > Description
428XL Users Manual Vol. 1 397
April 11, 2013
6
Stack
No correlation is performed on an auxiliary trace. Only stacking is
performed.
The order in which the result traces are written in SEGD files agrees
with the order of sequences in the description of the processings to be
done.
Correlation of seismic traces
Seismic traces can be correlated with an auxiliary trace (1 Pilot). Each
correlated trace is recorded on a single trace (positive time side).
If a trace is dead, then all its samples are zeroed.
Operation
More About Correlation > Data Distribution
398 428XL Users Manual Vol. 1
April 11, 2013
6
Data Distribution
Pilot length < Sweep length
Seismic trace correlation
Figure 6-126
Auxiliary trace correlation
Figure 6-127
Raw data or trace stacking
Figure 6-128

2
n

2
n

0
0
0
0
Pilot length
Aux trace (Pilot)
Sweep length +
record length
Seismic trace
(sweep length +record length)

0
0 0
0
2
n

2
n

Pilot length
Aux trace (Pilot)
Aux. trace
Sweep length +
record length
0
0
Pilot length
Aux trace
Sweep length +
record length
Seismic trace
(sweep length +record length)
Operation
More About Correlation > Data Distribution
428XL Users Manual Vol. 1 399
April 11, 2013
6
Pilot length = Sweep length
Seismic trace correlation
Figure 6-129
Auxiliary trace correlation
Figure 6-130
Raw data or trace stacking
Figure 6-131

2
n

2
n

0
0
0
0
Pilot length
Aux trace (Pilot)
Seismic trace
(sweep length +record length)
Sweep length +
record length

0
0 0
0
2
n

2
n

Pilot length
Aux trace (Pilot)
Aux. trace
Sweep length +
record length

0
0
Pilot length
Aux trace
Sweep length +
record length
Seismic trace
(sweep length +record length)
Operation
More About Correlation > Data Distribution
400 428XL Users Manual Vol. 1
April 11, 2013
6
Pilot length > Sweep length and s (Sweep length + Record
length)
Seismic trace correlation
Figure 6-132
Auxiliary trace correlation
Figure 6-133
Raw data or trace stacking
Figure 6-134

2
n

2
n

0
0
0
0
0
Pilot length
Aux trace (Pilot)
Seismic trace
(sweep length +record length)
Pilot length +
record length

0
0 0
0
2
n

2
n

Pilot length
Aux trace (Pilot)
Aux. trace
Pilot length +
record length
Pilot length
Aux trace
Seismic trace
(sweep length +record length)
Sweep length +
record length 0
0
Operation
More About Correlation > Data Distribution
428XL Users Manual Vol. 1 401
April 11, 2013
6
Pilot length > Sweep length and > (Sweep length + Record
length)
Seismic trace correlation
Figure 6-135
Auxiliary trace correlation
Figure 6-136
Raw data or trace stacking
Figure 6-137

2
n

2
n

0
0
0
0
0
Pilot length
Aux trace (Pilot)
Pilot length +
record length
Seismic trace
(sweep length +record length)

0
0 0
0
2
n

2
n

Pilot length
Aux trace (Pilot)
Aux. trace
Pilot length +
record length
Pilot length
Aux trace
Pilot length
0
0
Seismic trace
(sweep length +record length)
Operation
More About Correlation > Data Distribution
402 428XL Users Manual Vol. 1
April 11, 2013
6
428XL Users Manual Vol. 1 403
April 11, 2013
Chapter
7 Positioning
This chapter includes the following sections:
The main window (page 404)
The Setup menu (page 408)
The geographical view (page 418)
The Tracking view (page 434)
Vehicles (page 439)
The Alert system (page 444)
Working with the GIS (page 450)
Coord converter tool (page 455)
Basic Geodesy Glossary (page 456)
Positioning
The main window >
404 428XL Users Manual Vol. 1
April 11, 2013
7
The main window
To open the jPositioning main window, click on this icon in the
launcher bar.
The Positioning client window makes use of Receiver and Source SPS
files to generate an image of the spread, possibly superimposed on a
background map, so that you can monitor the progress of a seismic crew
in real time.
Figure 7-1
Vibrator status messages (including vibrator positions if each vibrator is
equipped with a radiopositioning receiver) are used to display actual
Positioning
The main window >
428XL Users Manual Vol. 1 405
April 11, 2013
7
source positions which are compared to expected ones for the purpose
of Quality Control.
The following major features are available:
Geographical view of your survey, based on the set of source points
and receiver points in it (see SPS files on page 581).
Geographical view of the instruments deployed. You can turn on/off
the lines (Field On/Off) just like in the Line window.
Viewing the progress of acquisitions in real time with:
- graphical display of the actual position of vibrators;
- calculation of the actual Centre of Gravity of the source, and
comparison with the planned point;
- predicted position of vibrators, depending on the stacking fold.
Launching a shot by simply dragging and dropping a source onto a
source point in the graphical view.
Real-time tracking of vehicles equipped with an MRU tracking
system; broadcasting waypoints to the tracked vehicles.
Enhancing safety in the crew with a variety of alerts (emergency
alarm, vehicle speed, inclusion/exclusion areas, etc.).
Requesting and building all sorts of reports and/or histograms on any
object appearing in the window, by simply clicking on the object in
the graphical view.
The View menu allows you to customize the main window by choosing
one or more views to display. For details on how you can arrange the
views and toolbars as you would like them, see the Hands-on guide
(page 52).
A GIS (Geographical Information System) is used to display the
geographical data in a multi-layer manner. The left-hand pane in the
Geographical view (Figure 7-1) reflects the structure of the GIS and
serves as a plot layer manager window for the different drawing layers
that can be plotted in the right-hand pane. See The layer manager
(page 422).
Positioning
The main window >
406 428XL Users Manual Vol. 1
April 11, 2013
7
A Coord converter tool (page 455) is available from the Window menu.
The following information is displayed in the locator bar at the foot of
the window:
Coordinates (Easting, Northing, Elevation) of the position the mouse
is pointing to, within the graphical view.
Line: number of the Line on which the mouse pointer is resting.
Point Nb: number of the point on which the mouse pointer is resting.
Distance: Distance between two points selected with the mouse.
WARNING
If a background map is loaded but not viewed, the map is still active and
used as reference for Source and/or Receiver position views. (The map
remains active until you unload it).
If you have multiple swaths to display, you can show/hide any of them
by double-clicking in the left-hand (layer manager) panel.
With many objects to display in the Instruments graphic view, the
system may switch to the checkerboard view mode because there is no
room for all icons, much like in the Line window. Also, if you zoom out
and objects become so close to one another that you cannot discriminate
between them, the system automatically removes some objects and
optimizes the amount of details as a function of the zoom factor and the
Spatial filtering parameter setting in the Preferences menu, which
increases the display speed. See Figure 7-2 on page 407.
In the Preferences Setup menu, the Tacking Views tab allows
specifying a default size for the tracking views, and the Background
color tab is used to choose the background colour. For the other tabs
(Auto Update and Memory) see the Hands-on guide (page 52).
Positioning
The main window >
428XL Users Manual Vol. 1 407
April 11, 2013
7
Figure 7-2
If the VE464 uses two TDMA radio boxes, the Enable/Disable
TDMA Tracking Mode right-click menu makes it possible to
discriminate between them, showing the DSDs associated with
TDMA #1 in blue, and those associated with TDMA #2 in orange.
Figure 7-3
Positioning
The Setup menu > The Datum Type setup
408 428XL Users Manual Vol. 1
April 11, 2013
7
The Setup menu
In this section:
The Datum Type setup (page 408)
The Projection Type setup (page 411)
Quality Warning setup window (page 413)
The Vehicle Identity setup (page 416)
The Datum Type setup
Figure 7-4
Positioning
The Setup menu > The Datum Type setup
428XL Users Manual Vol. 1 409
April 11, 2013
7
In order to locate a point on the earth you need to know its coordinates
and the geodetic DATUM.
To open this setup window, select Geodetic from the Setup menu and
click on the Datum Type tab. This setup allows you to display Datum
parameters and make any changes needed.
A Datum is defined with the following parameters:
Datum parameters
Datum Spheroid: datum name.
Semi-major Axis: allowable range 0.001 to 99999999.999 m.
Inverse Flattening: allowable range 0.0000001 to 9999.9999999.
Datum Shift parameters
X, Y, Z Shift: translation from WGS84 datum to the survey datum (in
metres).
- Shift Dx: allowable range -9999.999 to 9999.999 m.
- Shift Dy: allowable range -9999.999 to 9999.999 m.
- Shift Dz: allowable range -9999.999 to 9999.999 m.
X, Y, Z Rotation: rotation from WGS84 datum to the survey datum
(in seconds of arc).
- Shift Rx: allowable range -99.999 to 99.999 s.
- Shift Ry: allowable range -99.999 to 99.999 s.
- Shift Rz: allowable range -99.999 to 99.999 s.
Datum Scale Factor: allowable range 0.0000000001 to
1.1000000000. Note that the Scale Factor stands for the Scale
Difference which is usually expressed in Parts Per Million. For
example:
- if Scale Difference =+3 ppm, then Scale Factor =1.000003
- if Scale Difference =3 ppm then Scale Factor =0.999997
Positioning
The Setup menu > The Datum Type setup
410 428XL Users Manual Vol. 1
April 11, 2013
7
After entering all the parameters to define a Datum, you only need to
enter an identification number in the Nb field (allowable range 1 to 16),
and click Add then Apply to save the Datum type.
To view the parameters of any Datum type, double-click on it in the list
box (at the foot of the Setup window). Then you can make any changes
needed and click Change, or Add, or Delete, as required. To save your
changes, click Apply.
Note You can define up to 16 Datum types.
You select the Datum type to use through the Projection Type Setup.
Positioning
The Setup menu > The Projection Type setup
428XL Users Manual Vol. 1 411
April 11, 2013
7
The Projection Type setup
Your GPS receivers normally output GPGGA-type messages (Latitude,
Longitude, Altitude above the ellipsoid). The computer has to perform
a projection so that the position can be pinpointed on your survey map.
Figure 7-5
To open the Projection setup window, select Geodetic from the Setup
menu, then click on the Projection Type tab. This setup allows you to
display the projection parameters and make any changes needed.
Positioning
The Setup menu > The Projection Type setup
412 428XL Users Manual Vol. 1
April 11, 2013
7
The option button at the top (Currently used Projection Type) allows
you to choose which projection type to use.
A Projection Type is defined with the following parameters:
Datum Type: This option button is used to choose which Datum
Type to attach to the projection. You define Datum types through The
Datum Type setup (page 408).
Other parameters depending on the kind of projection used (Lambert,
UTM, etc.).
For angular parameters (Central Meridian, Latitude origin, Reference
Latitude, North Latitude, South Latitude, Skew Angle) the format is:
dddmmss.ss
(Degrees, Minutes, Seconds with two decimal places).
Examples:
Latitude North 16 4' 56.24" = 160456.24
South 16 4' 56.24" = -160456.24
Longitude East 120 1' 2.3" = 1200102.3
West 120 1' 2.3" = -1200102.3
Elevation referenced to (Geoidal Model/Local Ellipsoidal Model):
This option button allows you to choose the reference for the Surface
Elevation parameter which may appear in log files (APS, SPS, COG,
etc.):
- Geoidal Model: with this option, Surface Elevation is equal to
geoidal altitude +altitude correction
- Local Ellipsoidal Model: with this option, Surface Elevation is
equal to:
(geoidal altitude +geoidal separation) +altitude correction
Note The geoidal altitude and separation are extracted from
$GPGGA messages.
Positioning
The Setup menu > Quality Warning setup window
428XL Users Manual Vol. 1 413
April 11, 2013
7
After entering all the parameters to define a Projection, you only need
to enter an identification number in the Nb field (allowable range 1 to
16), and click Add then Apply to save the Projection type. This creates
a geodeticWkt.e428.xxxx file in the
snSol/workSpace/param/positioningServer directory. That file is
used by the VE464 Guidance software.
To view the parameters of any Projection type, double-click on it in the
list box (at the foot of the Setup window). Then you can make any
changes needed and click Change, or Add, or Delete, as required. To
save your changes, click Apply.
WARNING
If you are using DSUGPS units, after choosing the projection you must
go to Off Line in the jConfig window and, in the jLine window, set the
GPS reference position in the DSUGPS Setup menu (page 169) by
clicking on Apply in the Base Position tab, then go to On Line in
jConfig.
Note You can define up to 16 Projection types.
See also Coord converter tool (page 455).
Quality Warning setup window
Selecting Source Quality Warning from the Setup menu opens a
dialog box used to enter alert thresholds for source positions.
Figure 7-6
Click Apply to save and enable your changes.
Positioning
The Setup menu > Quality Warning setup window
414 428XL Users Manual Vol. 1
April 11, 2013
7
COG Radius Threshold
(Allowable range: 1. to 99.9 m). Determines the allowable area for the
actual COG around the planned source position. Each planned source
position in the graphic display is represented by a (blue) tolerance circle
the size of which is proportional to the COG Radius Threshold
parameter.
The actual Centre Of Gravity of the source is computed from the GPS
positions contained in the status messages transmitted by the vibrators
making up the source.
VP Grabbing Radius
(Allowable range: 1. to 99.9 m). Used in Navigation mode to determine
the eligible VP, if stacking is used and the fleet has to move after each
sweep within the VP. This parameter determines a larger circle around
the source COG tolerance circle. When a vibrator fleet is located within
the VP grabbing circle and ready to shake, the system chooses the
matching VP from the list of VPs in the Operation main window. See
VE432 or VE464 sweeps (page 307).
Figure 7-7
- For each acquisition, individual vibrator positions as well as the
fleets COG are displayed in the main window.
- The estimated COG of the VP is computed again at each
acquisition, using the actual COG of the acquisitions already
done and the predicted COG for the acquisitions still to be done.
COG
Acq1
Acq2
COG Radius
threshold
VP Grabbing
Radius
Planned source
Centre Of Gravity
COG tolerance
circle
VP grabbing
circle
Positioning
The Setup menu > Quality Warning setup window
428XL Users Manual Vol. 1 415
April 11, 2013
7
- After the VP is completed, the information about the acquisition
is replaced by the actual COG of the VP.
Note With no stacking (i. e. a single acquisition per VP), the VP
Grabbing Radius should be set to be equal to the COG Radius
Threshold. Otherwise, if the COG falls outside the COG
Radius Threshold circle but within the VP Grabbing circle, the
operator will not be warned of the COG radial error when the
Ready message appears but only after the VP is done (the alert
threshold associated with the Ready message is determined by
the largest of the two circles).
Vib Position Accuracy Threshold
(Allowable range: 0.0 to 99.9 m). This field is used to specify the
maximum allowable uncertainty on the GPS positions of the vibrators,
i.e. the maximum allowable value of the Horizontal Dilution Of
Precision contained in the status messages transmitted by the vibrators
making up the source. If the HDOP exceeds the Threshold specified in
this field, then the position is regarded as inaccurate.
About the vibrator position Quality Control
The quality of a vibrator's position is determined using the quality
figure contained in field No. 6 in the $GPGGA message from the GPS
receiver in the vibrator. The quality figure may assume values from 0 to
8. (See NMEA standard version 2.30).
The position is regarded as:
missing for values 0, 6, 7, 8,
natural (straight GPS) for 1,
actual for values 2, 3, 4, 5.
The Horizontal Dilution Of Precision (HDOP) is taken from field No. 8
in the $GPGGA message.
Positioning
The Setup menu > The Vehicle Identity setup
416 428XL Users Manual Vol. 1
April 11, 2013
7
The Vehicle Identity setup
To open this setup window, select Vehicle Ident from the Setup menu.
This setup allows you to specify which vehicles to track in the
Positioning window and, for each of them, specify the maximum
allowable speed.
Figure 7-8
Nb
(Allowable range: 1 to 50). Identity number of a vehicle, defined when
you configure the MRU for the vehicle. (See MRU User's Manual).
Name
Label you wish to assign to the vehicle identified in the Nb text box.
Max Speed
Determines the upper limit of the scale for colour-mapping the speed in
the vehicles trackline.
Tracking
For each vehicle in the list box this option button allows you to specify
whether or not the vehicle should be tracked in geographical views.
(Click in the field, then select the desired option from the button).
If you choose True, then MRU messages from that vehicle will be
interpreted. If you choose False, then the vehicle is not tracked, its
Positioning
The Setup menu > The Vehicle Identity setup
428XL Users Manual Vol. 1 417
April 11, 2013
7
MRU messages are rejected and no alarm is raised if that vehicle fails
to reply.
First Waypoint
Initialization value of the individual waypoint counter attached to each
vehicle tracked (by default: 1). This determines the waypoint number
that will be assigned to the first waypoint transmitted to any vehicle.
For a given vehicle, the waypoint number is incremented (up to 100)
each time a waypoint is transmitted to the vehicle. It is reset to the
current First Waypoint value in the event of overflow.
If you change the First Waypoint value, the new value will apply to
those vehicles which do not have any waypoint yet and those which
have a waypoint counter at 100.
To create a Vehicle Identity Setup
To define a new vehicle in the list box, fill in all the fields as required,
then click Add.
To make changes to any row in the list box, double-click on it, fill in the
fields above the list, then click Add or Change or Delete, as required.
To save and enable your changes, click Apply. (To revert to the former
settings, click Reset instead).
Positioning
The geographical view > General
418 428XL Users Manual Vol. 1
April 11, 2013
7
The geographical view
In this section:
General (page 418)
The layer manager (page 422)
Background (page 423)
GeoZones (page 425)
Swath (page 426)
Miscellaneous (page 428)
Vehicles (page 429)
Sources (page 430)
Line devices (page 432)
General
Figure 7-9 Geographical view
That is the basic view in the Positioning client window, consisting of:
a geographical view showing the planned source points and receiver
points imported from SPS files, the actual source points (calculated
COGs), service vehicles equipped with a tracking (MRU) box, the
Plot pane
Layer manager
pane
Graphical
Tools
Right-click to
view object
properties
Positioning
The geographical view > General
428XL Users Manual Vol. 1 419
April 11, 2013
7
sources (Shooters and/or VE464 fleets) created in the Operation
window;
a layer manager pane containing all the objects that can be viewed.
You can open as many geographical views as you like (using the View
menu). Each is independent and has its own layer manager.
Right-clicking on any object in or above the plot pane and selecting Get
Properties from the menu that pops up opens a secondary window
updated in real time, displaying the properties of the object.
Figure 7-10
Figure 7-11 Report document
You can use the Export Selected or Export All button to export
some or all of those properties. This generates a report document and
opens a preview window that allows you to save, print or export the
document by choosing whichever output format you like (PDF, XLS,
HTML, TXT, etc.) from its File menu.
Positioning
The geographical view > General
420 428XL Users Manual Vol. 1
April 11, 2013
7
Graphical tools
Figure 7-12 Graphical tools
Zoom in: after clicking on the Zoom in button, you can zoom in/out
by turning the mouse wheel forward/backward in the plot pane. Also,
you can use the left mouse button as follows: position the mouse in
one corner of the desired area, press the left mouse button and hold it
down, drag the mouse to the opposite corner of the area (this causes
a rubber-band box to appear) and release the button. As a result, the
region enclosed by the rubber-band box is redrawn within the same
view to occupy the entire plot pane.
Undo zoom: Reverts to the previous zoom factor.
View All: Zooms out until all objects fit into the plot pane (in one
click).
Zoom locker: Clicking on this button either locks or unlocks the
zoom-out factor, depending on whether it is already locked or
unlocked. With the zoom locker enabled, all zoom-out clicks will
take you back to the zoom factor you were using at the moment you
enabled it.
Panning: Clicking the Panning button causes the mouse pointer to
change to a hand when resting in the plot pane. Then you can drag the
focus point in any direction with the mouse.
Ruler: To read the distance from one point to another picked up in the
plot pane, click on the Ruler button, position the mouse on the first
point, press the left mouse button and hold it down, drag the mouse
to the other point. This draws a straight trackline in between. The
distance between the two points is displayed in a tip box on the first
Undo zoom
Panning View All
Rectangular
spatial query
Zoom in
Zoom
locker
Ruler
Circular spatial
query
Positioning
The geographical view > General
428XL Users Manual Vol. 1 421
April 11, 2013
7
point picked up. The latest distance picked up as you release the
mouse button is displayed in the Distance field in the locator bar.
Figure 7-13 Ruler
Rectangular or circular spatial query: Draws a rectangle or circle
area over displayed objects. As a result, all visible objects enclosed
by the rectangle or circle are grabbed, and a secondary window
appears, showing the list of grabbed objects and their properties.
Objects in hidden layers, if any, enclosed by the rectangle or circle are
ignored.
Figure 7-14 Spatial query
- You can use the Export
Selected or Export All button
to export some or all of grabbed
objects. This opens a dialog box
that lets you choose which
properties to export.
- Clicking Accept generates a report document and opens a
preview window (see Figure 7-11 on page 419) that allows you to
save, print or export the document by choosing whichever output
Refreshed as you
release mouse button
Tip box
Figure 7-15
Positioning
The geographical view > The layer manager
422 428XL Users Manual Vol. 1
April 11, 2013
7
format you like (PDF, XLS, HTML, TXT, etc.) from its File
menu.
The layer manager
In the layer manager (left-hand) pane, the available drawing layers are
grouped into several folders that you can expand or collapse (Source
sets, Vehicles, Miscellaneous elements, Swath, Geographical Zones,
Background maps, Line devices). If any layer is hidden, its name is
dimmed. Each layer has a specific popup menu, available by right
clicking on it, depending on which commands can be applied to that
layer.
Figure 7-16 Layer manager
To show or hide any drawing layer, first expand the appropriate folder,
then double-click on the desired layer, or right-click on it and select the
appropriate command (Show Layer / Hide Layer) from the menu that
pops up.
The Rename Layer command lets you enter whatever name you like in
place of the default name.
The Layer Properties command allows you to view and modify the
image properties, for example to change the opacity of the background
or to enable or disable smoothing.
Double-click to
expand/collapse folder
Double-click or
right-click to
show/hide layer
Plot pane
Layer manager
pane
Positioning
The geographical view > Background
428XL Users Manual Vol. 1 423
April 11, 2013
7
The Delete Layer command lets you delete the layer from the layer
manager (e. g. to unload a background map), but this does not delete the
file from your computers disk. Not all layers can be deleted.
The arrangement in the layer manager pane determines the way the
layers are stacked (i. e. overprinted) in the plot pane, the bottom folder
being plotted on the background and the top folder on the foreground.
You can move any layer by dragging it up or down to change the
overprinting order. Naturally, you must be aware that a raster file (the
background map) will hide any layer placed below it.
Background
The Background folder is dedicated to background images.
Figure 7-17 Background map
The following file types are allowed:
Geotiff: raster image with a geographical reference.
DXF: vectorial data.
Esri Shapefile: A shapefile stores non-topological geometry and
attribute information for the spatial features in a data set. The
geometry for a feature is stored as a shape comprising a set of vector
coordinates. Because shapefiles do not have the processing overhead
of a topological data structure, they have advantages over other data
sources such as faster drawing speed and edit ability. Shapefiles
handle single features that overlap or that are non-contiguous. They
also typically require less disk space and are easier to read and write.
Shapefiles can support point, line, and area features. Area features are
Positioning
The geographical view > Background
424 428XL Users Manual Vol. 1
April 11, 2013
7
represented as closed loop, double-digitized polygons. Attributes are
held in a dBASE format file. Each attribute record has a one-to-one
relationship with the associated shape record.
Simple Raster file (e. g. jpeg or gif or tif-format file): this type of file
has no geographical reference but the system lets you provide one as
you load such a file.
Right-clicking on any background layer and choosing Layer
Properties from the popup menu opens a dialog that allows you to
change the font and colour of labels if any, and adjust the following
image attributes.
Figure 7-18 Image properties
Opacity
This slider button controls how much of the background map will show
through.
Smoothing
The Optimal option applies appropriate smoothing for pixels not to be
visible, depending on the zoom factor. The Never option does not apply
any smoothing. The Always option achieves the best smoothing effect
but significantly increases the amount of CPU time consumed by your
Positioning window.
Positioning
The geographical view > GeoZones
428XL Users Manual Vol. 1 425
April 11, 2013
7
GeoZones
You may wish to be alerted if any tracked vehicle (vibrator equipped
with a GPS receiver or other vehicle equipped with a tracking system)
leaves the work area, or gets into quicksands or a boggy or no-
trespassing area, etc. The system will take care of that, using the
inclusion and/or exclusion zones contained in the GeoZones folder to
determine the allowable perimeter.
Figure 7-19 Inclusion/Exclusion zones
After you select Create Exclusion Zone or Create Inclusion Zone
from the popup menu, the mouse pointer changes to an arrow. Then you
can draw a polygon in the plot pane by clicking at each vertex in turn
and closing the polygon with a last click at the first vertex. This adds a
new item into the GeoZone folder. Right-click on it in the GeoZone
folder to rename it as you like.
Create Exclusion Zone
Allows you to define the perimeter of an area that the crews vehicles
are not allowed to enter. That perimeter is automatically plotted in red.
Create Inclusion Zone
Allows you to define the perimeter of an area that the crews vehicles
are not allowed to leave. That perimeter is automatically plotted in
green.
Right-click
Click
Positioning
The geographical view > Swath
426 428XL Users Manual Vol. 1
April 11, 2013
7
Load from file
Allows you to load a DXF-format file depicting the desired perimeter.
Each file you load creates a new item in the GeoZone folder. Only
closed curves are interpreted:
Red closed curves are interpreted as exclusion zones;
All other closed curves are by default interpreted as inclusion zones.
Other shapes if any included in the file are ignored.
Swath
For each swath, a separate layer is automatically created in the Swath
folder, showing the source points, and receiver points included in the
swath, as well as the instruments deployed. You can show/hide one or
more swaths by double-clicking on the relevant folders in the layer
manager.
Figure 7-20 Swath layer
Source points
Each planned source position (from the Source SPS file) is represented
by a blue circle. The size of the circle is proportional to the COG
Radius Threshold specified through the Setup menu.
Positioning
The geographical view > Swath
428XL Users Manual Vol. 1 427
April 11, 2013
7
Source COG
The COG position is represented by a solid
square inside the planned source position blue
circle if there is no radial error, or outside of
it if there is a radial error that is if the
deviation from the planned COG position
exceeds the COG Radius Threshold
specified through the Setup menu.
The solid square denoting the COG may be:
Green and inside the source blue circle if:
- this is the actual COG position (i.e all vibrator positions have
been received),
- and there is no radial error;
Red and inside the source blue circle if:
- this is the actual COG position (i.e. all vib positions have been
received),
- and one or more vib position standard deviations exceed the
Vib Position Accuracy Threshold (specified in the Setup
menu). The COG is therefore regarded as inaccurate.
Red and outside the source blue circle if:
- this is the actual COG position (i.e. all vib positions have been
received),
- but there is a radial error. In that case a warning box shows up,
displaying the radial error and the Source Point identification, so
that the operator can decide on whether to reposition the
vibrators and take the sweep again, or to continue.
Blank (not shown) if no position is received from one or more
vibrators (in the event of a malfunction in the GPS receiver or in the
radio link; in that case, no COG is computed).
Figure 7-21
Positioning
The geographical view > Miscellaneous
428 428XL Users Manual Vol. 1
April 11, 2013
7
If a VE432 system is used and the SQC Dump operating mode is
enabled in the Operation window, the COG layer is replaced by an FPS
(File Per Source) layer displaying the position of each vibrator.
Note If an Impulsive source is used instead of vibrators and the
blaster controller returns a position message ($GPGGA) to the
recording unit (e. g. with a SHOT PRO blaster) then the shot
point position is viewed.
Receiver Points
Each planned receiver position is represented as a yellow +mark.
Miscellaneous
The Misc folder in the layer manager pane contains the icons for the
recording unit and the base camp.
Figure 7-22 Miscellaneous objects layer
By default, if the icon file includes a geographical reference, the icon is
displayed at its exact location in the geographical view, otherwise the
object appears only in the layer manager pane.
You can place the recording unit or base camp icon into the plot pane by
dragging and dropping it from the layer manager pane to the plot pane
(left-click on it in the layer manager while pressing the Ctrl key, then
move the mouse to the desired location in the plot pane and release the
mouse button). Likewise you can move the icon within the plot pane by
dragging and dropping it where you would like it to appear.
Drag and drop
to move icon
Recording
truck icon
Positioning
The geographical view > Vehicles
428XL Users Manual Vol. 1 429
April 11, 2013
7
To place the recording unit or base camp icon at its exact location, right-
click on its folder in the layer manager pane, and select Edit
coordinates from the menu that pops up. This opens a dialog box that
allows you to show or hide the icon (by ticking/unticking the Visible
option), and enter its precise Easting and Northing.
Figure 7-23
Alternatively, you can enter the precise coordinates of the recording unit
or base camp in the Log window (see Editing/saving/loading 428XL
parameters on page 576).
Vehicles
If a vehicle tracking system is attached to the server computer, the
Vehicles folder in the layer manager pane contains all the vehicles
equipped with a tracking box (MRU). You can monitor the position of
those vehicles in real time, show/hide their tracklines and also send
waypoints to them by simply dragging and dropping a vehicles icon to
the desired location.
See Vehicles on page 439 for details.
Positioning
The geographical view > Sources
430 428XL Users Manual Vol. 1
April 11, 2013
7
Sources
This folder contains all the sources created in the Operation window
that you can use to take shots or sweeps.
A flag (for a vibroseismic source) or human figure (for an impulsive
source) icon associated with each source is available above the plot
pane. Depending on the option selected from the Action button,
dragging and dropping a source icon into the plot pane will simulate a
Ready signal from a fleet or generate a Go To Waypoint command.
Ready
Figure 7-24 Source layer
You can drag a source icon and drop it onto a planned shot point in the
plot pane to associate it with that shot point and launch a shot just like
a click on Go would do in the Operation window. To do that, select
Ready from the Action button, left-click on the source icon while
pressing the Ctrl key, then move the mouse to the desired planned shot
point and release the mouse button. To help you aim, a small square
with the same colour as the source flag appears inside the targeted
source point circle.
For example, this allows you to redo a sweep without lifting the vibrator
pads. Dragging and dropping the vibroseismic source simulates the
Ready signal sent by the fleets leader when all its vibrators have their
pads down. You must have clicked on Go at least once beforehand in
the Operation window. Also, the fleets vibrators are assumed
Vibroseismic
source
Impulsive source
shooter
Drag and drop
to launch sweep or shot
Denotes the
targeted source
point
Positioning
The geographical view > Sources
428XL Users Manual Vol. 1 431
April 11, 2013
7
positioned at the shot point, with their pads down. You also have to click
on the fleets button in the VE464 orVE432 main window, unless that is
already done, to let its Ready status be relayed to the acquisition system.
Go To Waypoint
If a fleets vibrators use the VE464 orVE432 Guidance tool, you can
drag and drop the fleets icon to the plot pane to divert the fleet to a
particular source point (for example a source point that was not properly
done). To do that, select Goto Waypoint from the Action button, then
drag and drop the fleet icon to the desired source point. This causes the
system to transmit the latitude and longitude of that source point to the
fleets DSDs, just like the Go To Waypoint dialogue box in jOperation
would do.
Figure 7-25 Source layer
Drag and drop
to steer to source point
Positioning
The geographical view > Line devices
432 428XL Users Manual Vol. 1
April 11, 2013
7
Line devices
The Positioning window has one layer for each of the Line windows
topographical views (Instrument, Sensors, Battery, Seismonitor). The
Instrument layer displays all instruments, cables, and radio links. Right-
clicking on any object displays its properties just like in the Line
window.
Double-clicking on an instrument or a sensor moves the focus to that
element in all the topographical and numerical views in the Line
window.
Figure 7-26 Line Devices layer (Intruments)
Figure 7-27 DSUGPS receiver points
LCI
Transverse path
Position accuracy not OK,
GPS on (yellow)
Position accuracy OK,
GPS off (green)
Too few satellites,
GPS on (red)
No position, GPS off
(grey)
Positioning
The geographical view > Line devices
428XL Users Manual Vol. 1 433
April 11, 2013
7
Below is the colour code for the DSUGPS icon:
Grey: GPS is off and position is not determined.
Blue (briefly): request for turning GPS on, or waiting for a reply.
Red: GPS is on, but tracking too few satellites (less than two) after
the first calculation.
Yellow: GPS is on and tracking two or more satellites, or before the
first calculation of position.
Green: the position is determined with the required accuracy, and
GPS is off.
The Seismonitor layer displays a colour map of the seismic noise level.
Figure 7-28 Line Devices layer (Seismonitor)
Positioning
The Tracking view > Graphical tracking view
434 428XL Users Manual Vol. 1
April 11, 2013
7
The Tracking view
In this section:
Graphical tracking view (page 434)
Numerical tracking view (page 437)
More about the estimated COG position (page 437)
Graphical tracking view
In the source tracking view are all the details on the Vibrator Point:
positions of vibrators (crosshair), the planned active Vibrator Point, the
predicted COG (orange square, or green if the stacking fold is
achieved), and information about the current VP (Acquisition number/
stacking fold, Device number, Source Point Line, Source Point Number,
Source Point Index).
Figure 7-29
The button in the upper left corner allows you to freeze/unfreeze the
view. Preventing the view from being updated may be helpful if you
need time to examine details. Since you can open as many tracking
views as you like (using the View menu), you can enable updating in
another view and still track the active source.
In each view, you can use any of the fleet (flag) buttons available at the
top to choose whichever fleet you would like to be tracked in that view.
If you do not choose any fleet, then the active source is tracked.
V1
V2
V3
Planned
COG
Fleet
Enable/disable
updating
Choose fleet
to view
Positioning
The Tracking view > Graphical tracking view
428XL Users Manual Vol. 1 435
April 11, 2013
7
The tracking view shows the progress of vibrator positions and source
positions updated as soon as the status messages are received from the
vibrators. The solid square denoting the COG is:
Orange and inside the source blue circle if:
- this is an estimated COG position (i.e. some vib positions have
not yet been received),
- but the estimation does not lead to any radial error.
Orange and outside the source blue circle if:
- this is an estimated COG position (some vib positions have not
yet been received),
- and the estimation leads to a radial error (e.g. a status message is
indicating that a vibrator failed to vibrate. Therefore the
estimated COG is computed without the position of this vibrator,
leading to a radial error).
Note that COG radial errors are reported in the form of messages in the
mail pane at the foot of the window.
Figure 7-30
Each planned vibrator position is represented as a +mark which
changes from orange (i.e. estimated) to green as the actual position is
received. It turns red if the positions standard deviation exceeds the
Vib Position Accuracy Threshold specified through the Setup
menu. It is not shown if any of the status codes of the following
malfunctions is encountered:
- no sweep
- no status report
- position message error
Positioning
The Tracking view > Graphical tracking view
436 428XL Users Manual Vol. 1
April 11, 2013
7
- no GPS position samples
The vibrator positions used in the latest acquisition are annotated
with the vibrator numbers.
The vibrator positions of those previous source points which are OK
(green solid square) are not shown.
Until the status messages are received from all the vibrators making up
the source, the theoretical centre of gravity of the source is estimated
from the vibrator pattern of the previous source point and represented
by a solid orange square. See More about the estimated COG position
(page 437). When status messages are received, the COG is shown as
explained above for the geographical view.
In Navigation mode with a Stack Order more than 1:
- For each acquisition within a VP, individual vibrator positions as
well as the fleets COG are displayed.
- The estimated COG of the VP is computed again at each
acquisition, using the actual COG of the acquisitions already
done and the predicted COG for the acquisitions still to be done.
- After the VP is completed, the information about the acquisition
is replaced by the actual COG of the VP.
v
Note When you generate the RAW daily Observer Report, at the end
of the day, the SPS Source file in the database is
automatically updated with the actual source COG positions.
(You can use the Log main window to save the updated source
file to an archival medium).
The Elevation reported is the elevation value contained in the $GPGGA
messages from radiopositioning receivers (referenced to the geoidal
model).
Positioning
The Tracking view > Numerical tracking view
428XL Users Manual Vol. 1 437
April 11, 2013
7
Numerical tracking view
You can monitor one or more vehicles in real time by right-clicking on
the vehicle and choosing Numerical Track on from the menu that pops
up. This opens a view pane that continually displays:
The position of the vehicle (Line name and Receiver Point).
The distance to the nearest line.
The vehicles speed: the line is displayed in red if the vehicle is
motionless.
Figure 7-31
More about the estimated COG position
Prediction table
The planned source positions (represented by blue circles) are known at
the outset as they are contained in Source SPS files. On the contrary, the
vibrator pattern is not known until all the vib positions of the first
complete pattern have been received.
For example, if 2 acquisitions are taken with 4 vibrators then 8 status
messages will be received, containing 8 vib positions, which will be
used to compute the actual COG but also to set up a prediction table. An
example is shown below.
DSD Number
Acquisition
1 2
V1 dx11, dy11 dx12, dy12
V2 dx21, dy21 dx22, dy22
V3 dx31, dy31 dx32, dy32
V4 dx41, dy41 dx42, dy42
Positioning
The Tracking view > More about the estimated COG position
438 428XL Users Manual Vol. 1
April 11, 2013
7
The dx,dy values are horizontal and vertical offset distances between
each latest known vibrator position and the latest actual COG position
(green solid square).
Figure 7-32
Locating the estimated COG
From the prediction table the dx,dy pair corresponding to the first
vibrator which, in the current pattern, supplied its actual position (green
+mark) is chosen to locate the estimated COG.
The estimated COG position (orange solid square) is obtained by
adding the selected dx,dy pair (from the prediction table) to the actual
easting and northing (respectively) received for this vibrator.
Then the remaining dx,dy pairs in the prediction table are used to locate
the estimated positions of the other vibrators with respect to the
estimated COG.
The estimated vib pattern is represented by orange +marks.
V1.1
dx
dy
Latest actual COG
Latest actual vib
position
Positioning
Vehicles > Overview
428XL Users Manual Vol. 1 439
April 11, 2013
7
Vehicles
In this section:
Overview (page 439)
Supported vehicle tracking systems (page 440)
Customizing tracked vehicles (page 442)
Vehicle trackline and history file (page 443)
Overview
Figure 7-33
Any vehicle equipped with a SERCEL MRU or Racal type tracking unit
can send its position computed by a radio-positioning receiver and

GPS

GPS
GPS
Tracking
Tracking
Tracking
Tracking
Recording station
(Lab)
Monitoring station
(Camp)
P
osition+A
larm W
a
y
p
o
in
ts
+
S
e
rv
ic
e
m
e
s
s
a
g
e
s
S
e
r
v
i
c
e

m
e
s
s
a
g
e
s
Positioning
Vehicles > Supported vehicle tracking systems
440 428XL Users Manual Vol. 1
April 11, 2013
7
status to a base station, and receive waypoints and/or messages from the
base station. This requires that the base station be equipped with a
tracking box too. For reference information on the necessary
communications scheme, see the MRU or Racal User's Manual. See
also Supported vehicle tracking systems (page 440).
The base station can be the GUI computer in the recording truck
(referred to as Lab) or a monitoring station (referred to as Camp).
On the base station, whether it be a Lab or Camp station, the Positioning
client window must be open.
Periodically, each tracked vehicle reports its latest position and status to
the base station, which updates the position in the Positioning windows
graphic pane.
Supported vehicle tracking systems
To track the position of your vibrators and service vehicles, you can use
SERCEL MRU boxes or an equivalent type of tracking box from
RACAL.
MRU type: To configure an MRU as Vibrator or Service Vehicle, see
the MRU Users Manual. The message supplied by an MRU includes
the position, the type of unit (Vibrator or Service vehicle) and the
alarm status if any.
Racal type: By default a Racal-type tracking box is identified as
Service vehicle. To identify it as a Vibrator, a serial port must be
modified. The message supplied by a Racal tracking box includes the
position, the type of unit (Vibrator or Service vehicle) and the alarm
status if any, and the type of message encoded as follows
(1character):
- E: Alarm (interpreted as Vehicle +Alarm).
- F: Interpreted as Vibrator.
- Other: Interpreted as Vehicle.
An option button in the Installation client window on the computer lets
the user choose which type of tracking box to use.
Positioning
Vehicles > Supported vehicle tracking systems
428XL Users Manual Vol. 1 441
April 11, 2013
7
The tracking box connects to the computer through a serial line (A- and/
or B-port of the computer).
Figure 7-34
A-port
The computers A-port:
Receives the position and alarms from the vehicles.
Sends waypoints and service messages to the vehicles.
It is also used to send specific commands to the tracking box. For
example, with a Racal tracking box, changing the record unit position
sends the command $PASHS,POS (record unit position). A hardware
switch is required between the port of the computer and that of the
tracking box.
The computers A-port is configured as follows:
With SERCEL (MRU) tracking boxes: 4800 Bauds, 8 data bits, 2
stops bits, no parity.
With Racal-type tracking boxes: 9600 Bauds, 8 data bits, 2 stops bits,
no parity.
B-port
The computers B-port receives services messages exchanged by the
Lab and Camp computers.
It is configured as follows:
With SERCEL (MRU) tracking boxes: 9600 bauds, 8 data bits, 2
stops bits, no parity.
Tracking box
Position
Port A
Port B
Service message
Waypoint, Service message
or printer
Computer
Port A
Port B
Positioning
Vehicles > Customizing tracked vehicles
442 428XL Users Manual Vol. 1
April 11, 2013
7
With Racal-type tracking boxes: 4800 bauds, 8 data bits, 2 stops bits,
no parity.
Note If the A-port is used for another link, the B port can be used in
place of it for the messages to and from the tracked vehicles. In
that case, communications between Lab and Camp computers
cannot be handled by the tracking box.
Customizing tracked vehicles
Right-clicking on the Vehicles folder in the layer manager and selecting
Add Vehicle Group opens a secondary window that allows you to
create vehicle groups and customize the aspect of vehicles in each
group.
Figure 7-35
Each time you add a new group, a subfolder is created in the layer
manager (hence a sublayer in the plot pane). As a result, you can apply
specific actions to the whole sublayer, for example:
- Rename the group;
- Send a request for specific attributes in order to find the
matching vehicles (using the name, or GPS identifier number or
any other attribute as search criterion);
(Name=Fuel)
Fuel
Positioning
Vehicles > Vehicle trackline and history file
428XL Users Manual Vol. 1 443
April 11, 2013
7
- Assign an icon of your own to the vehicles in the group, rather
than using the default icon.
Vehicle trackline and history file
The trackline of each vehicle and also the associated alerts are
automatically saved to an XML log file on the client computers disk (in
the Jpos/workspace/history directory) and sorted by julian day. That
file can be imported into any viewing tool accepting XML files.
Real-time display
Right-click on the vehicles subfolder in the layer manager pane and
select Show trace route from the menu that pops up.
The trackline is displayed as segments the colour of which depends on
the speed of the vehicle.
The speed is mapped with 10 different colours starting from green
(standing for the vehicles minimum speed) to red (standing for the
maximum allowable speed specified in the The Vehicle Identity setup on
page 416. A circle appears on the trackline if any alarm is raised.
Playback from history file
Selecting Load History from the File menu allows you to choose a
trackline history file and load it to the Backgrounds folder in the layer
manager pane. Then the trackline can be displayed like any real-time
trackline (with colour-mapped speed and circles on incidents) and
shown/hidden like any other background layer.
Positioning
The Alert system > Emergency
444 428XL Users Manual Vol. 1
April 11, 2013
7
The Alert system
You can set alert conditions on vehicles by using the setup menu or the
toolbar, or simply right-clicking on a vehicle.
You are notified of any incident in two ways:
An audible warning plus a visual effect in the geographical view (an
expanding circle around the vehicle that caused the incident). The
colour of the expanding circle depends on the type of incident.
A tip box popping up as you drag the mouse over any vehicle affected
by an incident.
To dismiss an incident on a vehicle, either double-click on the vehicle
or right-click on it and choose Reset Alert from the menu that pops up.
This may or may not let you get rid of the alert, depending on the type
of incident.
Incidents are saved together with the trackline (meaning that they will
be visible when you play back the trackline).
The following types of incidents are monitored:
Emergency (page 444)
GeoZone perimeter (page 445)
Global alarms (page 446)
Excess speed (page 448)
Emergency
The system continually checks for any Emergency alert from the MRU
system (an Emergency alarm is automatically raised if a vehicles driver
pushes the Emergency button on the MRU tracking box). This requires
that the Tracking option in the The Vehicle Identity setup (page 416) be
set at True.
An Emergency alarm immediately causes a dialog box to show up in the
Positioning window, with the position of the vehicle at the moment the
alarm was raised.
Positioning
The Alert system > GeoZone perimeter
428XL Users Manual Vol. 1 445
April 11, 2013
7
Figure 7-36
Clicking the Send Help button automatically sends a waypoint to the
nearest three vehicles to that position, allowing for rescue as quickly
as possible. (This also dismisses the alert window).
If the vehicle does not need any help, simply click Reset Alarm when
you want to dismiss the alert window.
GeoZone perimeter
Inclusion/exclusion zones are created by drawing closed curves in
geographical views or loading DXF files depicting such zones (see
GeoZones on page 425). GeoZones are intended for vehicles equipped
with an MRU system, and for all vibrators (with or without an MRU).
A visual alarm is raised (an orange expanding circle around the position
of a vehicle), and a GeoZone perimeter incident is reported, if a vehicle
or vibrator:
- enters an exclusion area;
- leaves an inclusion area.
The visual alarm disappears when the vehicle gets back to the allowable
perimeter, or if you delete the inclusion/exclusion zones affected (or
you double-click on the vehicle).
An inclusion/exclusion zone is active (can give rise to incidents) even
if hidden.
Positioning
The Alert system > Global alarms
446 428XL Users Manual Vol. 1
April 11, 2013
7
Global alarms
All vehicles and vibrators equipped with an MRU system and for which
the Tracking option in The Vehicle Identity setup (page 416) is set at
True can be checked for the following types of incidents: Emergency,
No Reply, No Move, Camp Distance, Lab distance.
The monitoring of all these incidents is optional, except for
Emergency alarms. On vibrators, No move incidents are ignored.
Clicking on this button in the toolbar opens a dialog box that
allows you to choose which incidents to monitor and adjust the
alert conditions.
Figure 7-37
In the event of an incident on a vehicle, a visual alarm is raised (an
orange expanding circle around the vehicle) and the incident is reported
in the log file. The visual alarm disappears when the situation goes back
to normal (or if you dismiss it by double-clicking on the vehicle).
The type of unit (metres, feet, etc.) for the Distance and Radius fields
is determined in the The Projection Type setup (page 411).
No Reply
Alerts you if the position of a vehicle fails to be refreshed within the
time (seconds) you specify in the Delay field, for instance if no position
message is received from the vehicle.
Positioning
The Alert system > Global alarms
428XL Users Manual Vol. 1 447
April 11, 2013
7
No Move
Alerts you if a vehicle remains at a standstill (i. e. the position is
refreshed but remains within the circle determined by the associated
Distance field) for the time you specify in the Delay field (seconds).
Because of the so-called noise on the position, especially with
straight GPS, two successive positions from a vehicle can be different
even though the vehicle doesnt move. The system will only assume the
vehicle is moving if the distance between two successive positions
exceeds the distance (metres) you specify in the Distance field.
Camp Distance
Alerts you if the distance from a vehicle to the Camp location exceeds
the distance (metres) you specify in the associated Radius field (i. e. the
position of the vehicle doesnt fall within the circle determined by that
radius around the Camp location).
Lab Distance
Alerts you if the distance from a vehicle to the Lab (recording unit)
location exceeds the distance (metres) you specify in the associated
Radius field (i. e. the position of the vehicle doesnt fall within the
circle determined by that radius around the Lab location).
Positioning
The Alert system > Excess speed
448 428XL Users Manual Vol. 1
April 11, 2013
7
Excess speed
All vehicles equipped with an MRU system and for which the Tracking
option in The Vehicle Identity setup (page 416) is set at True can be
checked for speed excess.
Right-clicking on any of those vehicles opens a dialog box that allows
you to set the speed alert conditions for that vehicle. Therefore, you can
set individual speed alert conditions on each vehicle.
Figure 7-38
For each vehicle monitored, the speed is computed as the ratio of the
difference between the last two positions received to the difference
between the times when they are received.
In the event of an Excess speed incident on a vehicle, a visual alarm
is raised (an orange expanding circle around the vehicle) and the
incident is reported in the log file. The visual alarm disappears when the
situation goes back to normal (or if you dismiss it by double-clicking on
the vehicle). On vibrators, Excess speed incidents are ignored.
Max Speed
Tick this option if you want the vehicle to be checked for excess speed.
Untick to disable monitoring.
Delay
Use this field to specify the desired time interval (seconds) between two
speed tests on this vehicle.
Positioning
The Alert system > Excess speed
428XL Users Manual Vol. 1 449
April 11, 2013
7
Speed
Use this field to specify the desired speed limit for this vehicle,
expressed in km/hr or miles per hour, depending on the type of unit
selected (see The Projection Type setup on page 411).
Additional Effects
Use the options if you want excess speed incidents to open a dialog box
and/or generate an audible warning for this vehicle.
Positioning
Working with the GIS > Object labelling
450 428XL Users Manual Vol. 1
April 11, 2013
7
Working with the GIS
In this section:
Object labelling (page 450)
Attribute colour maps (page 451)
Query builder (page 453)
Object labelling
Each object appearing in a geographical view
can be annotated with a tag reporting
whichever of its attributes you choose. Those
tags are updated in real time, and do not
overprint one another. The more you zoom
in, the more tags are visible.
To create a tag and show or hide it, right-click
on the desired folder in the layer manager
pane (Source Point, Source Receiver, COG,
or Vehicles) and choose Label Properties
from the menu that pops up.
In the example below, vehicles have a label displaying the name and
speed.
Figure 7-40
Figure 7-39
Positioning
Working with the GIS > Attribute colour maps
428XL Users Manual Vol. 1 451
April 11, 2013
7
Attribute colour maps
A Classifier tool is available for the items contained in the Swath layer
(Source Point, Source Receiver, COG).
This allows you to create classes for the different values of an objects
attribute and have them colour-mapped in a geographical view. You can
choose the number of classes to create and which colours to use for the
colour mapping.
For example, assuming you want to have a colour-map view of the
source average distortion (an attribute available on COGs), then:
1. Right-click on the COG folder in the layer manager pane and
choose Classifier from the menu that pops up. This opens the
Classifier control window.
Figure 7-41
2. From the Feature Property Names option button, choose the
attribute to plot (Average Distortion).
3. From the Bins option button, choose the number of classes to
create.
4. Click on the Start button and select the desired colour for the
lowest value class.
5. Click on the End button and select the desired colour for the
highest value class.
6. Click on Preview to view the result in a Histogram window.
Positioning
Working with the GIS > Attribute colour maps
452 428XL Users Manual Vol. 1
April 11, 2013
7
Figure 7-42
7. Click on Apply. As a result, the average distortion is colour-
mapped in the COG layer in the geographical view.
Figure 7-43
To remove the colour map effect and go back to the default colour
encoding in the geographical view, right-click on the appropriate folder
in the layer manager and select Reset Queries and Classification
from the menu that pops up.
Colour-mapped average
distortion in COG layer
Positioning
Working with the GIS > Query builder
428XL Users Manual Vol. 1 453
April 11, 2013
7
Query builder
A Query Builder tool is available for the items contained in the Swath
layer (Source Point, Source Receiver, COG).
The Query Builder allows you to build any kind of query on displayed
objects on any attributes of an object, with logical operators (Or, And,
Not, etc.), and generate professional reports in PDF, HTML, XCELL
files, etc.
For example, assuming you want to get the list of COGs with an average
distortion greater than 16, then:
1. Right-click on the COG folder in the layer manager pane and
choose Build feature query from the menu that pops up. This
opens the query builder window for COGs.
Figure 7-44
2. Select the desired attribute from the Property Name list box.
Save and load back your
queries as you like.
The items matching your query can
be displayed in a geographical view.
Positioning
Working with the GIS > Query builder
454 428XL Users Manual Vol. 1
April 11, 2013
7
3. Choose the desired operator.
4. Choose the desired value from the Values list box.
5. Click on Add To Query.
6. If you want to preview the items matching your query in a
geographical view, click on the Create Selection button.
7. Clicking on the Generate Report button opens a secondary
window that lets you choose which attributes to export. Unless
you want to include all, untick those you want to discard by
clicking in the associated Export Enabled button.
Figure 7-45
8. Clicking Accept generates a report document and opens a preview
window (see Figure 7-11 on page 419) that allows you to save,
print or export the document by choosing whichever output
format you like (PDF, XLS, HTML, TXT, etc.) from its File
menu.
Figure 7-46
Positioning
Coord converter tool >
428XL Users Manual Vol. 1 455
April 11, 2013
7
Coord converter tool
The coordinates transformation tool available from the Window menu
allows you to convert coordinates from WGS84 to your favourite
geodetic system or the other way round.
Figure 7-47
Select the
Projection to use
(from those created
in The Projection
Type setup on
page 411)
Type the
coordinates to
convert in the
appropriate fields,
depending on
which way you
want to do the
conversion
Click on the appropriate button, depending on
which way you want to do the conversion
Positioning
Basic Geodesy Glossary >
456 428XL Users Manual Vol. 1
April 11, 2013
7
Basic Geodesy Glossary
Datum: Datum results from taking an ellipsoid and moving its centre
so the ellipsoid matches the geoid very closely in your area of
interest. For example, in Europe, the International ellipsoid is shifted
to fit and called ED50 (European Datum 1950).
For the same location, your latitude and longitude are different on
different Datums. Since your GPS receivers normally output on
WGS84 you need to convert the WGS84 latitude/longitude to a
latitude /longitude on whatever Datum you are surveying on. This is
done by on-line Datum transformation routines in SERCEL software.
This is why you are required to select the appropriate Datum. See The
Projection Type setup (page 411).
Ellipsoid: An ellipse which has been rotated about an axis (example:
WGS84). The shape of the ellipsoid is chosen to match the geoidal
surface as closely as possible.
Geoid: An equipotential surface (meaning that the pull of gravity is
equal everywhere along the surface), approximately corresponding to
the Mean Sea Level. A plumb bob always points perpendicular to the
geoid, not to centre of the earth.
Projection: A projection is a representation of a 3 dimensional plane.
In order to make a section of the ellipsoid into a flat surface, you have
to stretch some parts of the surface and compress other parts. The
amount of compressing/stretching is known as scale factor.
The distance you measure in the real world is usually not equal to the
distance measured on the projection.
428XL Users Manual Vol. 1 457
April 11, 2013
Chapter
8 Export
This chapter describes the jExport client window. It
includes the following sections:
The main window (page 458)
File export controls (page 460)
The Tape Setup menu (page 465)
The Functions menu (page 468)
Recorder activity logs (page 477)
Exporting to NAS disks (page 481)
Exporting to a virtual NAS (page 487)
Working with tape drives (page 492)
Disk space monitoring (page 493)
Export
The main window >
458 428XL Users Manual Vol. 1
April 11, 2013
8
The main window
To open the jExport main window, click on this icon in the
launcher bar.
The 428XL automatically saves its shot files to an SEGD repository on
its server computers disk. The Export main window is dedicated to the
process of exporting them from the SEGD repository to your archiving
media: disks (NAS, Virtual NAS) and/or tape drives. Each file is not
deleted from the SEGD repository until its has been exported
successfully. The activity of each type of medium is logged in a separate
view (Tape, NFS, FTP).
Figure 8-1
The View menu allows you to open a separate view for each type of
export target (Tape, NFS server, FTP server), showing a table in which
the activity of the export process is logged. For details on how you can
arrange the views and toolbars as you would like them, see the Hands-
on guide (page 52). You can move and resize columns in tables by right-
clicking in any column heading and selecting Customize (see Figure 2-
25).
In the toolbar are indicators showing the status of each device to which
the shot files can be exported. See Export device indicators (page 460).
Export
The main window >
428XL Users Manual Vol. 1 459
April 11, 2013
8
The Functions menu is used for local controls of tape drives, mounting/
unmounting NFS disks, making an FTP connection, and for playback.
See The Functions menu (page 468).
Export
File export controls > Export device indicators
460 428XL Users Manual Vol. 1
April 11, 2013
8
File export controls
In this section:
Export device indicators (page 460)
Auto/Manual (page 462)
Export device indicators
In the Install window, you can choose to record your SEGD files to
cartridges and/or export them in real time to one or two disks
simultaneously, or to an FTP server on the local network. See Export
mode (page 74).
In the Export windows toolbar, an indicator is associated with each
export device you enabled in the Install window. With the mouse
pointer resting on the indicator, a tip box pops up that shows the status
of the export device. Also, the status is shown by the colour of the
indicator light (red/orange/green), as explained in detail below.
Figure 8-2
Tape drives
Up to 4 tape drives (identified as Device numbers 0 to 6) can be attached
to the SCSI bus. As soon as a tape drive is connected on the bus and
powered up, an indicator light appears in the toolbar in the main
window, displaying its Device number (that is the SCSI address
assigned to the tape drive by the user or the Operating System). The
indicator light is:
Not shown: if the tape drive is not connected or not powered up;
Red: if the tape drive is connected and powered up, but no cartridge
is inserted. The indicator turns red when the cartridge is ejected:
Export device
indicators
Status tip box
Export
File export controls > Export device indicators
428XL Users Manual Vol. 1 461
April 11, 2013
8
- manually by the operator,
- or automatically when the number of files on the cartridge (File
Count field in the Tape view) matches your Files per Tape
(page 467) setting.
Orange: if the tape drive is connected and powered up, with a
cartridge inserted (the tape is at the BOT);
Green: if the tape drive is connected and powered up, with a cartridge
inserted and currently used for recording.
If two or more tape drives are attached to the system and you want to
know which is associated to each Tape indicator (because you do not
know which SCSI address is assigned to each drive), insert a cartridge
into one drive and look at the indicators to see which drive has a
cartridge inserted (or move the mouse pointer to each Tape indicator to
display the status popup).
FTP server and NFS disks
In the main windows toolbar, an indicator light is associated with each
NFS disk and with the FTP server, if you have selected these options in
the Install window. The colour of the indicator should be interpreted as
follows:
Red: device unmounted or not mounted (NFS connection) or not
accessible (FTP connection). The indicator turns red if the removable
disk is unmounted or the FTP connection is closed:
- manually by the operator,
- or automatically, because of a problem on the network.
Orange: device mounted (NFS connection) or accessible (FTP
connection).
Green: device mounted (NFS connection) or accessible (FTP
connection), and writing to that device is in progress or enabled.
The disks (NFS devices) are removable but cannot be unmounted while
a file is being written.
Export
File export controls > Auto/Manual
462 428XL Users Manual Vol. 1
April 11, 2013
8
Auto/Manual
Figure 8-3
The system takes shots regardless of the status of any tape drive or other
export target, unless and until the SEGD repository disk space is
running out.
Choosing Manual enables the local control functions and causes the
system to stop exporting data (but data acquisition can continue so long
as the SEGD repository disk space is not running out).
For example, you have to go to Manual if you want to change the
working mode option (Data/Bypass), or to unload a tape, or to replace
an NFS disk.
Choosing Auto opens a secondary window that allows you to enable
file exports.
Figure 8-4
The available export devices are prompted in the Devices List box.
A removable disk is ready if it is mounted.
An FTP server is ready if connection to it is successful.
Click to enable
exports
Disk#1
Disk#2
Export
File export controls > Auto/Manual
428XL Users Manual Vol. 1 463
April 11, 2013
8
A tape drive is available if:
- its cartridge is blank;
- its cartridge is not blank but the tape is positioned at the end of
the last record. To go to the end of the last record, choose
Manual and use the Playback function (Last Record).
The data is exported from the directory selected in the Dump Directory
field. Note that if you are recording multiple swaths, unless you choose
the Flat Backup settings option in the Config windows Disk Record
setup (page 95) the seismic data is saved to a separate directory for each
swath in the SEGD repository. In that case use the Browse button to
select the swath directory containing the largest volume of data, and
remember you may have to switch to another swath directory at a later
date to empty it, and so on and so forth. You may want to use the Flat
Backup settings option to avoid the need to change directory, but in that
case the data is not sorted by swath name and you must wonder if you
agree to having data from different swaths on the same tape.
If you are exporting to NFS disks, you can export records from multiple
swaths concurrently. See Multi-swath shots (page 485) for details.
To enable file exports, you simply have to choose Data as working
mode, choose (click on) the device you want to export to (in the list
box), and then click on Go. To select two devices in the list box, press
and hold down the CTRL key while clicking.
Data/Bypass
Choosing Data enables the normal export function. This is the option
to use for production.
Choosing Bypass enables the data to be dumped to the plotter (and
the eSQC-Pro server if any) without recording to tape or exporting. The
system asks you if you really want to go to Bypass. To change the
dump directory, you have to go to Data.
With the Bypass option, all activity log views remain blank.
Export
File export controls > Auto/Manual
464 428XL Users Manual Vol. 1
April 11, 2013
8
Simult
If two or more tape drives are attached to the system and you choose the
Simultaneous option, then the seismic data is recorded on two drives
concurrently (the first two reported ready, i. e. visible to the system
and with a cartridge inserted).
Go button
Clicking Go inhibits the local control functions and enables the
Export process to copy files from the SEGD repository to the export
targets (tape drives, removable disks or FTP server) you have selected
from the Devices List box. If any SEGD file is available, after the
required devices are successfully selected, then it is copied to those
export targets. As a result the indicator of each export target selected
turns green and remains green so long as a file is being written to it.
In the event of an error in the export process, the system automatically
goes to Manual and an error message appears in the Status Mail
view. The file that was being recorded when the error arose is not
deleted from the SEGD repository.
If any of the export targets you select fails to be accessed, a message
(Waiting for device ready) shows up in the Status Mail view,
telling you which device gave rise to the error. The data cannot be
exported to any device.
If a cartridge is write-protected, or closed by a double EOF, it cannot be
selected. If any tape drive is required but cannot be selected, one of the
following messages may show up in the Status view:
- Waiting for device ready (if no cartridge is inserted).
- or Device # not at end of last record (if a non-blank cartridge
is inserted).
Export
The Tape Setup menu >
428XL Users Manual Vol. 1 465
April 11, 2013
8
The Tape Setup menu
To enable recording to a tape, you must choose the Tape Drive option
as Export Mode in the Install window.
Selecting Tape Setup from the Setup menu opens a secondary window
with the following parameters:
Figure 8-5
Tape Set
If you are shooting multiple swaths, you may want to create a distinct
Tape Set (a set of tape numbers) for each swath. This allows exporting
the different swaths to distinct directories on NFS disks (NAS). Note
that the Tape Set field is only intended for exporting to NFS disks, not
tapes.
The Tape Set field contains the identification number of each Tape
Set. Each Tape Set consists of the tape numbers ranging from the value
specified in the associated First Tape Nb field to that specified in the
Last Tape Nb field.
The Swath setup (page 97) in the Config window allows you to select
which Tape Set to associate with which swath.
For example, if you are exporting to NAS disks, files from
/var/dump/swath1/jdayXXX/ on the server can be recorded to
swath1/Tape1/jdayXXX/ on the NAS, while files from
/swath2/jdayXXX/ are recorded to swath2/Tape100/jdayXXX/. See
Exporting to NAS disks (page 481) for more information.
Export
The Tape Setup menu >
466 428XL Users Manual Vol. 1
April 11, 2013
8
First Tape Nb
Used to specify the lowest tape number in the Tape set.
Last Tape Nb
Used to specify the highest tape number in the Tape set.
The First and Last Tape Nb fields determine how many tapes can be
recorded using this set of tape numbers, that is the size of the Tape Set.
Be sure the size is consistent with the amount of production files
expected and the number of files per tape. If you generate more files
than planned in the Tape Set, the system will display a warning in the
Config window, and the Export window will go to Manual. In that case,
exports will be suspended and you will have to create a new Tape Set
and select it in the Config window (in the Swath Setup) to resume
exporting.
Current Tape Nb
(Allowable range: 0 to 9999).
This field contains the reel tape number recorded in the header block of
the latest SEGD files exported. It is automatically incremented after the
Burst is written on a tape or after the number of files exported reaches
the value specified in the Files per tape field. This parameter is still
used (updated and recorded) if you are exporting to NFS disks rather
than tape drives. This makes it easier to copy the files to a tape at a later
date.
Tape Label
(16 ASCII characters max.). Used to enter a user-friendly name for the
reel tape #. This field is not used if you are recording SEGD Rev. 2.1
files.
External Label (only for SEGD Rev. 2.1 files)
This field allows you to specify the physical label of the tape, if it has
one (ASCII characters, 12 max.), to be recorded in the Tape Label
Export
The Tape Setup menu >
428XL Users Manual Vol. 1 467
April 11, 2013
8
block. See Use External Tape Labels (page 94) option in the Config
windows SEGD setup.
User Defined (only for SEGD Rev. 2.1 files)
This field allows you to enter any other information about the tape
(ASCII characters, 14 max.), to be recorded in the Tape Label block.
See Use External Tape Labels (page 94) option in the Config windows
SEGD setup.
Files per Tape
(Allowable range: 1 to 1000000). Allows you to specify the maximum
number of SEGD files that can be recorded to each tape. This parameter
is still used if you are exporting to NFS disks rather than tape drives (it
is used to update the Tape Number).
Trace Blocking
To improve the system cycle time when recording to a tape drive, you
can shorten the record time by activating the Trace Blocking option.
With that option enabled, several traces are grouped to form a single
block limited to the size (128, or 256 or 512 kilobytes) you choose with
the associated dropdown list button.
A block contains a whole number of traces. Not all blocks will be the
same size. Traces in a block may be part of different channel sets.
Bytes #20 to 22 in Block #1 of the General Header of the SEGD record
tell you whether or not traces are recorded in blocked mode: if traces are
recorded in blocked mode, then the value in Bytes #20-22 is 100000,
otherwise 000000.
Unless you choose the Trace Blocking option, the system will record
traces to tape as individual blocks separated by a gap.
When you play back any record on the 428XL, the system automatically
chooses the appropriate option.
Export
The Functions menu > NFS disk
468 428XL Users Manual Vol. 1
April 11, 2013
8
The Functions menu
In this section:
NFS disk (page 468)
FTP server (page 469)
Tape (page 470)
Get Device Info (page 472)
Playback (page 472)
Copy (page 475)
Reinit Export (page 476)
NFS disk
This setup window allows you to specify the IP address of each external
disk attached to the system, and the directory to which to save your
SEGD files.
Figure 8-7
After connecting an external disk, you have enter the IP address of that
disk on the local network, enter the directory path to which to save your
SEGD files on that disk, and then click on the Mount button.
The following IP addresses are allowed:
172.27.128.41
172.27.128.42
172.27.128.43
172.27.128.44
Figure 8-6
172.27.128.41
172.27.128.42
/mnt/raid
/mnt/raid
Export
The Functions menu > FTP server
428XL Users Manual Vol. 1 469
April 11, 2013
8
The Mount (Unmount) button attaches (detaches) the specified remote
directory to (from) the file hierarchy of the server computer at a mount
point automatically determined by the system.
Note Prior to removing a disk, click on the associated Unmount
button. Disks cannot be unmounted while a file is being written.
Figure 8-8
See also Exporting to a virtual NAS (page 487).
FTP server
To export your SEGD files to an FTP server attached to the local
network, you must choose the FTP Server option as Export Mode
in the Install window.
Selecting FTP from the Functions menu opens a secondary window
with the following parameters:
Figure 8-9
In the Login and Password fields, enter the log-in name and
password (the user account) that the FTP user will use to connect to
the FTP server. By default, the user account is userftp (with userftp
as Password). This assumes that the same user account is created on
the FTP server machine.
172.27.128.2
(172.27.128.x.)
172.27.128.1
GUI
172.27.128.41
Local network
Observer NAS
server
428XL server
Export
The Functions menu > Tape
470 428XL Users Manual Vol. 1
April 11, 2013
8
In the Address field, specify an IP address (172.27.128.xx) for the
machine on which FTP server software (e. g. FileZilla supplied on the
SERCEL CD-ROM) is installed. For example, you can use
172.27.128.99.
In the Remote directory field, enter the name of the directory to
which the records will be saved on the FTP server machine.
Figure 8-10
Tape
Selecting Tape from the Functions menu opens a secondary window
with a list box prompting the tape drives that are ready (i. e. visible to
the system, with a cartridge inserted). After choosing a tape drive (by
clicking on it in the list box), you can use the commands available from
the option button. (Click on Go to launch the command).
Figure 8-11
EOF
This function causes a second End of File to be written after the latest
one. (An EOF is automatically written at the end of each record). The
172.27.128.2
(172.27.128.x.)
172.27.128.1
GUI FileZilla
172.27.128.99
Local network
Observer
FTP user
428XL server
Tape#1
Tape#2
Export
The Functions menu > Tape
428XL Users Manual Vol. 1 471
April 11, 2013
8
second EOF is usually interpreted as the end of the tape. This resets the
File Count to 0.
Note Two EOFs in succession are automatically recorded when the
end of tape is sensed in the course of a record or when the file
count reaches the Files per Tape count. If simultaneous
recording on two tape drives is selected (see Auto functions
menu) then a double EOF is written on both tape drives.
Release
Tape drives are normally locked by the 428XL application, meaning
that they are not available to any other application. The Release
command allows you to choose a tape drive and release it so that it can
be used by another application, e. g. if you want to use the Copy Media
utility (See 428XL Users Manual Vol. 3).
When you want to use the tape drive again, choose Reinit Export from
the Commands menu.
Rewind
Sends a Rewind command to one or more tape drives.
Unload
Sends an Unload command to one or more tape drives.
EOM
(End Of Media). Used to go to the last filemark.
Export
The Functions menu > Get Device Info
472 428XL Users Manual Vol. 1
April 11, 2013
8
Get Device Info
Figure 8-12
This function is used to display detailed status information about the
available recording media.
Simply click in the list box to select the device to view and then click
Go.
Figure 8-13
Playback
Selecting Playback from the Functions menu opens a dialog box that
allows you to read an SEGD file from the record device you choose in
the Source Devices list box (prompting the list of devices reported
ready), and view it on the plotter or the QC tool, or both, depending on
what you choose with the Target Devices buttons.
Export
The Functions menu > Playback
428XL Users Manual Vol. 1 473
April 11, 2013
8
Playback from an NFS disk
Figure 8-14
1. If any NFS disk is mounted, it appears in the list box. Choose
the device from which to read by clicking on it in the list box.
2. Use the Browse button to open the folder containing the file you
want to read and select it.
3. Click Go.
The record number of the file you are reading is displayed in the NFS
activity log view.
Playback from a tape drive
1. If you are using a tape drive, it appears in the list box if it is visible
to the system and a cartridge is inserted in it. Click in the list box
to choose the tape drive from which to read.
Figure 8-15
2. Choose a read option from option button:
- Last Record: used for a playback of the preceding record. The
tape will be wound back then forward so as to find a header with
Tape#1
Tape#2
Export
The Functions menu > Playback
474 428XL Users Manual Vol. 1
April 11, 2013
8
a Record Number matching the Record Number of the latest file
recorded. Playback will start as soon as the expected header is
encountered. You can also use this function to position the tape
at the end of the latest record.
- Next Record: used for a playback of the next record. Whatever
the position of the tape, the tape drive will perform a forward
search for the next record header and start the playback as soon
as a header is encountered.
- Forward: the record to be played back is assumed to be located
AFTER the current position on the tape. You have to specify the
desired record number in the Sequential File Nb field. The
tape drive will perform a forward search for the header of the
specified record. When the header is encountered, the tape drive
will wind back the tape into the gap preceding the header and
restart forward, to read the header again, and perform playback.
- Backward: the record to be played back is assumed to be located
AHEAD OF the current position on the tape. You have to specify
the desired record number in the Sequential File Nb field. The
recorder will perform a backward search for the header of the
specified record, then, when the header is encountered, perform
playback.
- Sequential File Nb: if you want to use the Forward or
Backward read option, use this field to specify which file to
read from the tape.
Note The header cannot be read backward. Instead, on each EOF
encountered during the backward search, the next header is read
forward, and the backward search continues until the desired
header is encountered.
3. Click OK.
The record number of the file you are reading is displayed in the Tape
activity log view.
Export
The Functions menu > Copy
428XL Users Manual Vol. 1 475
April 11, 2013
8
Copy
The Copy function allows you to copy an SEGD file from a disk (not
from the SEGD repository) to another disk or to a tape drive. This
function is dimmed and not available unless and until you go to
Manual.
If any NFS disk is mounted and/or any tape is loaded, it appears in the
Available Devices list box.
1. Choose the device from which to read by clicking on it in the
Available Devices list box, and then move it to the Source list
box by clicking on the right pointing arrow button under that list
box.
2. Likewise, select the device to which to write and then move it to
the Target list box.
Figure 8-16
3. Use the Browse button to open the folder containing the file you
want to copy and select it.
4. Click Go.
The record number of the file you are reading is displayed in the
relevant activity log view.
Disk2
Use arrow button
to move
Export
The Functions menu > Reinit Export
476 428XL Users Manual Vol. 1
April 11, 2013
8
Reinit Export
In the event of a problem on the SCSI bus or on the network, you can
enable exports again by using Reinit Export, rather than doing Off
Line/On Line in the Config window.
If you power up a tape drive after booting up the server computer, or in
the event of fatal error on the SCSI bus, use this command to reset the
SCSI bus.
Also, you have to use Reinit Export when you want to enable exports
to a tape drive again after it has been released for another application
(see Release on page 471).
If you are using an FTP server, you can use Reinit Export to see if the
system successfully connects to it.
Export
Recorder activity logs >
428XL Users Manual Vol. 1 477
April 11, 2013
8
Recorder activity logs
The 428XL recording activity is visible in three types of log views.
In the Operation main window, the information logged from the
shots completed is displayed in real time in the Operation Report
view while the SEGD file is written to the SEGD repository.
In the Export main window, the log view for each type of export
target displays the information logged while writing to the export
target in real time. See the description of each field below.
In the Log main window, the Observer Log view lets you select
some or all of the fields from Operation logs and Export logs, and
build an observer report that you can print and/or export to another
application.
The View menu in the Export window allows you to open a separate
view for each type of export target (Tape, NFS server, FTP server),
showing a table in which the activity of the export process is logged.
Figure 8-17 NFS export log view
Export
Recorder activity logs >
478 428XL Users Manual Vol. 1
April 11, 2013
8
Figure 8-18 FTP export log view
Figure 8-19 Tape export log view
Swath Id
Identification number of the swath (parameter from the Operation
window). Depending on your Backup Settings (page 95) in the
Configuration window, a subdirectory can be created for each swath in
the SEGD file repository used for temporary storage.
Device Id
Identification number assigned by the Export process to the export
target.
J ulian Day
(NFS and FTP export reports only). Depending on your Backup Settings
(page 95) in the Configuration window, a subdirectory can be created
for each J ulian Day in the SEGD file repository used for temporary
storage.
File #
Identification number of each SEGD file written to the removable disk,
or FTP server, or tape. This field can also display the number of a file
you are playing back.
Export
Recorder activity logs >
428XL Users Manual Vol. 1 479
April 11, 2013
8
Tape #
(Tape drive and NFS export reports only). Identification number of the
tape currently used, automatically incremented on writing the first file
after the File Count is reset to 0. If you are exporting to NFS disks,
the Tape number is still updated so that files can easily be copied to a
tape at a later date.
If two tape drives or two NFS disks are used simultaneously, two report
rows (one for each export target) are displayed for each SEGD file.
File Count
(Tape drive and NFS export reports only). Number of SEGD files
written to or read from the current tape. This number is automatically
reset to 0 when a double EOF is recorded to a tape (manually or when
the File Count matches your Files per Tape setting) or when a blank
cartridge is loaded. See The Tape Setup menu (page 465).
Device Name
(NFS and FTP export reports only). Automatically determined by the
system. If you are using NFS disks, that is the disk identification
number entered by the user when configuring the NFS disk. See 428XL
Installation Manual.
Server Name
(NFS and FTP export reports only). IP address of the NFS disk or FTP
server machine, entered using the The Functions menu (page 468).
Remote Folder
(NFS and FTP export reports only). Directory to which SEGD files are
exported, on the FTP server or NFS disks, entered using the The
Functions menu (page 468).
Export
Recorder activity logs >
480 428XL Users Manual Vol. 1
April 11, 2013
8
File Name
(NFS and FTP export reports only). Automatically created by the
system with the File number and segd as extension.
Time
Time of writing to the removable disk, or FTP server, or tape.
Error
Indicates whether or not the SEGD file was recorded successfully.
Error Text
If an error occurred when recording the SEGD file, this field contains
the error message generated by export target.
SCSI address
(Tape Drive reports only). SCSI address entered by the user on the tape
drive.
Tape Label
(Tape Drive reports only). From The Tape Setup menu (page 465).
Files per Tape
(Tape Drive reports only). From The Tape Setup menu (page 465).
Write Retries
(Tape Drive reports only). Number of attempts to write the specified
file.
Trace Blocking
(Tape Drive reports only). From The Tape Setup menu (page 465).
Export
Exporting to NAS disks >
428XL Users Manual Vol. 1 481
April 11, 2013
8
Exporting to NAS disks
Below is the typical procedure for exporting shots from a single swath
to a NAS. To export to multiple disks, see Exporting to a virtual NAS
(page 487).
1. In the Install window, set the maximum number of NFS servers
and select the type.
Figure 8-20
2. In the Export window:
- In the (NFS) Disk function window, enter the NAS disk IP
address and click the Mount button. As result, the /mnt/raid
partition of the NAS is automatically attached to the
/tmp/diskN (where N may be from 00 to 20) partition on the
428XL server computer.
Figure 8-21
- In the Tape Setup window, create a Tape Set with a large enough
range of tape numbers to record all the production files.
Figure 8-22
/mnt/raid 172.27.128.41
1 1000 1 150
1 1000 1 150
1
1
Export
Exporting to NAS disks >
482 428XL Users Manual Vol. 1
April 11, 2013
8
3. In the Config window,
- In the Swath setup, create a Swath Number and assigns the Tape
Set (e. g. Tape Set 1) to that swath. Set the initial File Number.
Figure 8-23
- In the Disk Record setup, choose the Standard mode (this will
save production files to /var/dump/normal and test files to
/var/dump/test).
Figure 8-24
4. In the Export window, switch to Auto. Choose the disk you want
to export to, and use the Browse button to select which Dump
directory to export from (select /var/dump).
Figure 8-25
swath1
swath1
Disk#1 /var/dump
Export
Exporting to NAS disks >
428XL Users Manual Vol. 1 483
April 11, 2013
8
As a result of the above settings, all production files and test files will
be recorded automatically to the NAS (production files will be recorded
to /mnt/raid/normal/<tapeNb>/<fileNb>and test files to
/mnt/raid/test/<tapeNb>/<fileNb>).
If you want to shoot multiple swaths, you can export them concurrently
to distinct directories on the NAS as follows:
1. Use The Tape Setup menu (page 465) to create a distinct Tape
Set (set of tape numbers) for each swath.
2. In the Config window:
- In the Swath setup, select which Tape Set to associate with
which Swath.
- In the Record Disk setup, choose the Advanced mode and the
Swath name option.
3. Go to Auto in the Export window and select /var/dump as Dump
directory. See the example in Figure 8-29 on page 485.
Export mechanism
In the illustrations below, magenta is used to indicate what is populated
by Config, blue to indicate what is populated by the Export process.
Figure 8-26
jConfig
jExport
Disk Record
Setup
Export
Exporting to NAS disks >
484 428XL Users Manual Vol. 1
April 11, 2013
8
Single-swath shots
In the two examples below, the Standard Disk Record mode is
selected, in the Config window, which is well suited for recording shots
from a single swath. In Standard mode, production files are saved to
/var/dump/normal, and test files to /var/dump/test.
Figure 8-27 shows what is recorded on the NAS if the operator selects
the /var/dump directory when going to Auto in the Export window
(the whole /var/dump directory is exported).
Figure 8-27 Exporting a single swath from /var/dump
Figure 8-28 shows what is recorded on the NAS if the operator selects
the /var/dump/normal directory when going to Auto in the Export
window (only production files are exported).
Figure 8-28 Exporting a single swath from /var/dump/normal
jConfig
jExport
Disk Record
Setup: Standard
Selected:
/var/dump
jConfig
jExport
Selected:
/var/dump/normal
Disk Record
Setup: Standard
Export
Exporting to NAS disks >
428XL Users Manual Vol. 1 485
April 11, 2013
8
Multi-swath shots
In the two examples below, the Advanced Disk Record mode is
selected in the Config window, which is well suited for recording shots
from multiple swaths. In Advanced mode, choosing the Swath Name
option creates a subdirectory for each swath.
Figure 8-29 shows what is recorded on the NAS if the operator selects
the /var/dump directory when going to Auto in the Export window.
This allows exporting two swaths concurrently and also test shots (i. e.
the whole /var/dump directory). The operator does not need to switch
between the different swath subdirectories created on the server.
Figure 8-29 Exporting two swaths from /var/dump
Figure 8-30 shows what is recorded on the NAS if the operator selects
the /var/dump/swath1 directory when going to Auto in the Export
window. (Only swath1 is exported).
Figure 8-30 Exporting from /var/dump/swath1
jConfig
jExport
Disk Record
Setup: Advanced
Selected:
/var/dump
jConfig jExport
Selected:
/var/dump/swath1
Disk Record
Setup: Advanced
Export
Exporting to NAS disks > Copying exported files
486 428XL Users Manual Vol. 1
April 11, 2013
8
Copying exported files
So long as the disk is attached to the local network, you can copy your
SEGD files to a tape by going to OFF Line in the Config window and
then using the CopyMedia utility (see 428XL Users Manual Vol. 3), or
using the Copy (page 475) function menu.
After the NAS system is removed, you can connect it to an Ethernet port
on a UNIX workstation and mount the exported (/mnt/raid) directory
at the workstations mount point, using the command:
mount <Host name or IP address>:/mnt/raid /<mount point>.
To copy your SEGD files from the NAS system to a tape, you can also
use the Copy+ software tool available from SERCEL on a computer
running on Linux or a personal computer running on Windows
TM
,
equipped with an SCSI port. After connecting the NAS system to the
Ethernet port of the computer, you have to specify its IP address (e. g.
172.27.128.41) by doing the following:
Linux host computer
On a computer running on Linux:
Create an intellique0 (or intellique1) directory in the tmp
directory;
Under the root account, type the following command in a Terminal
window:
/bin/mount -t nfs -o hard 172.27.128.41:/mnt/raid /tmp/intellique0
Windows host computer
On a PC running on Windows:
Choose Map Network Drive from the Tools menu in the Windows
Explorer;
Specify the IP address of the NAS disk.
For details, see: Peripherals in 428XL Installation Manual and
Utilities in Users Manual Vol. 3.
Export
Exporting to a virtual NAS > Overview
428XL Users Manual Vol. 1 487
April 11, 2013
8
Exporting to a virtual NAS
In this section:
Overview (page 487)
Virtual NAS Setup (page 488)
NFS mount function (page 490)
Auto/Manual (page 491)
Overview
In a high channel count survey, to achieve the necessary recording
speed for real-time acquisition, you can group two or more NAS4000
units into a Virtual NAS.
Figure 8-31
Those NAS4000 units that are part of a Virtual NAS are used in a round-
robin manner to record shot files with the same tape number. If any
member in the Virtual NAS becomes unavailable (e. g. because it gets
NAS4000
172.27.128.42
172.27.128.41
File Num.
1
4
7
10
etc.
Vitual tape
File Num
sw1/tape1/Num.1
sw1/tape1/Num.2
sw1/tape1/Num.3
sw1/tape1/Num.4
sw1/tape1/Num.5
sw1/tape1/Num.6
sw1/tape1/Num.7
sw1/tape1/Num.8
sw1/tape1/Num.9
sw1/tape1/Num.10
sw1/tape1/Num.11
sw1/tape1/Num.12
etc.
File Num.
2
5
8
11
etc.
Virtual NAS #1
172.27.128.43
File Num.
3
6
9
12
etc.
Export
Exporting to a virtual NAS > Virtual NAS Setup
488 428XL Users Manual Vol. 1
April 11, 2013
8
full), the jExport process automatically elects to write the next file to the
next available member in that Virtual NAS.
Virtual NAS Setup
To open the Virtual NAS setup, select Virtual NAS from the Setup
menu.

Figure 8-32 Virtual NAS setup
To enter a NAS4000 into a Virtual NAS, click in the Disk Label field
and select a Disk number for this NAS4000, then click Add. (To remove
a disk from the Virtual NAS, select it in the list box and click Delete).
Note that each disk number can be associated with only one virtual
NAS.
To create a new Virtual NAS, click on Add Virtual NAS. This creates
a new tab, and the lowest formerly unused virtual NAS number is
automatically assigned to the new Virtual NAS. (To delete a Virtual
NAS, click Delete Virtual NAS). Note that you cannot create more
than 10 virtual NASs.
Export
Exporting to a virtual NAS > Virtual NAS Setup
428XL Users Manual Vol. 1 489
April 11, 2013
8
Figure 8-33
Your changes are not saved until you click Apply. So long as you do not
click Apply, you can restore the previous settings by clicking Reset.
You are not allowed to make any changes to the Virtual NAS setup
unless you switch to Manual in the main window.
Note that the Virtual NAS setup is only available if you select the
NAS4000 type of NFS server in the jIntall Export mode setup. Also,
you must set the Max number of NFS Servers as appropriate.
Whenever you change this maximum number, the Virtual NAS setup is
cleared, and the IP addresses in the NFS mount function (page 490)
dialogue box are cleared too.
Figure 8-34 jInstall setup
Export
Exporting to a virtual NAS > NFS mount function
490 428XL Users Manual Vol. 1
April 11, 2013
8
NFS mount function
To specify the IP address of each NAS4000 attached to the system, and
the directory to which to save your SEGD files, select Disk NFS from
the Functions menu.
Figure 8-35
This setup window automatically adjusts itself so as to prompt as many
(up to 20) Mount buttons as specified by the Max number of NFS
Servers setting in jInstall.
Virtual NAS status indicator
In the main window, each virtual NAS created in the Virtual NAS setup
window has a status indicator, much like any other NFS disk.
Figure 8-36
The status may be one of these:
Ready (orange), meaning that one at least of the NAS4000 units
making up the Virtual NAS is mounted.
Selected (green), meaning that one at least of the NAS4000 units
making up the Virtual NAS is write selected.
Export
Exporting to a virtual NAS > Auto/Manual
428XL Users Manual Vol. 1 491
April 11, 2013
8
Not ready (red), meaning that none of the NAS4000 units making up
the Virtual NAS is mounted.
Auto/Manual
Figure 8-37
All virtual NASs that are ready and all NFS disks mounted appear in
the Devices List box. You can select two of them, and click Go, to
export SEGD files to these two devices simultaneously:
You can select one Virtual NAS and one NFS disk, unless this NFS
disk is part of the selected Virtual NAS.
You cannot select more than one Virtual NAS.
To mount or unmount disks, go to Manual. and select the NFS mount
function (page 490).
Export
Working with tape drives >
492 428XL Users Manual Vol. 1
April 11, 2013
8
Working with tape drives
Cartridge insertion
If cartridge insertion fails on a 3490E (MPTAPE Cypress, ECHO,
XCERTA) drive, do the following:
Go to OFF mode, using the buttons on the tape drive.
Insert the new tape.
Wait a little while (until all processes on the tape drive are
completed), then go back to ON mode.
End of tape detection
On a 3490E (MPTAPE Cypress, ECHO, XCERTA) drive, if the
observer attempts to record more than the tape nominal capacity, the
drive fails to diagnose properly the end of tape. No error is issued, thus
allowing record to continue but files are unreadable.
The Files per Tape must always be computed in accordance with tape
capacity to avoid this situation.
Export
Disk space monitoring >
428XL Users Manual Vol. 1 493
April 11, 2013
8
Disk space monitoring
The Disk Monitoring command available from the View menu
displays information on the used space in partitions in the storage
volume. The disk space information is not only available to the operator
but also used by each process to alert the operator if storage space is
running out.
Figure 8-38 Disk monitoring view
Disk space information is displayed graphically with a bar-graph
(normally green, orange if the used space is reaching a critical size, red
if space is running out) and in numeric form (used space percentage).
The alert thresholds for each partition you want to monitor are
adjustable by selecting Disk Monitoring from the Setup menu.
Figure 8-39 Disk monitoring setup
Monitoring a partition means the used space in that partition is tested
periodically and the operator is alerted if space is running out. The
Export
Disk space monitoring >
494 428XL Users Manual Vol. 1
April 11, 2013
8
Partition Setup window is used to specify which partitions should be
monitored, and set the refresh rate and alert parameters for each of
them.
By default, three important partitions are monitored (you cannot delete
them from the list of monitored partitions):
.../workspace/result (partition for results to display in GUI views);
/var/tmp (partition used for storing log files);
/var/dump (partition or mount point used as SEGD file repository).
You can monitor any other partition mounted (e. g. a removable disk)
by specifying its name (e. g. /var/rmdisk) in the Partition field and
clicking Add.
The Name field allows you to give it a self-explanatory name.
For each partition monitored, the Warning level (%) and Critical
level (%) fields allow you to adjust the used space percentage that will
cause the bargraph to go orange (for an early warning) or red (for a state
of emergency). For example, to set the red alert level for the /var/tmp
partition to 80%, do the following:
- Click on the /var/tmp row in the list box.
- Type 80 in the Critical level (%) field.
- Click Change, then Apply.
The Period button allows you to specify the refresh rate of the test for
used space in each partition. For the three partitions that are monitored
by default, you cannot change the test period. (Because used space in
those partitions depends on the acquisition length, the test period
defaults to the acquisition length).
The Visible button associated with each partition allows you to enable
or disable monitoring (except for the three partitions that are
systematically monitored).
428XL Users Manual Vol. 1 495
April 11, 2013
Chapter
9 VE464
This chapter includes the following sections:
The main window (page 496)
The Vibrator Crew setup (page 498)
The Basic Type setup (page 501)
The Acquisition Type setup (page 518)
The Radio Management setup (page 522)
The QC Limit setup (page 529)
The Sweep Management setup (page 530)
The Pattern setup window (page 532)
Functions (page 536)
Normal acquisition (page 558)
Statistics views (page 566)
VE464
The main window >
496 428XL Users Manual Vol. 1
April 11, 2013
9
The main window
The VE464 window is only available if you choose the VE464
Vibrator type (page 72) option in the Install window.
To open the VE464 main window, click on this icon in the
launcher bar.
This main window serves as the Graphic User Interface for a VE464
vibrator controller (VE464 DPG). For an introduction to the VE464
system and details on what it is able to do, how it works, how to deploy
it, see the VE464 Users manual.
Figure 9-1
The View menu and the associated toolbar allow you to customize the
main window by choosing one or more views to display. Then you can
resize your display panes by dragging the desired border.
You can show or hide columns in tables by right-clicking in any column
heading and selecting Customize (see Figure 2-25).
The Setups menu and the associated toolbar allow you to customize
sweep signals, set parameters for vibrator fleets and adjust QC
parameters.
Setup toolbar
Click to show
view
Click to close view
Function toolbar
VE464
The main window >
428XL Users Manual Vol. 1 497
April 11, 2013
9
The Functions menu and the associated toolbar provide local controls
to be used outside of seismic acquisition periods to adjust the
parameters of vibrator DSDs.
VE464
The Vibrator Crew setup >
498 428XL Users Manual Vol. 1
April 11, 2013
9
The Vibrator Crew setup
Figure 9-2
The Vibrator Crew setup dialog box is used to describe a seismic crew
by creating the list of vibrators available in that crew, that is the list of
vibrator electronics (DSDs) to be controlled by the recorders GUI, and
creating the list of vibrator groups (fleets) to build.
To save the description of the crew, click Apply. This updates the status
bar under the function buttons in the main window: an indicator appears
for each DSD incorporated in a fleet, associated with the identification
number of the vibrator (e. g. V1, V2, etc.). The indicator is blank until
you run the Fleet function.
Clicking Apply also clears all the vibrators lists in the dialog boxes that
will open when you click some of the function buttons (Set DSD, Get
DSD, etc.)
As a result, you have to run the Fleet function to update the vibrators
lists.
Clicking Reset instead of Apply reverts to the former settings.
Crew Nb
This field is used to enter the crew identification number (1 to 4).
A DPG can address only one crew. The crew identification number is
used to preclude any interference with other crews working nearby.
VE464
The Vibrator Crew setup >
428XL Users Manual Vol. 1 499
April 11, 2013
9
DSD Id
This field is used to specify the identification number (1 to 32) of each
vibrator (i. e. DSD) that the GUIs VE464 main window has to control.
DSD Type
This option button allows you to choose between two options for each
DSD in the list box:
Vibrator, that is the standard option, to be selected if the DSD is
used to control a vibrator;
Slave, if the DSD is used to control a slave recording system (i. e.
if it is used as a DPG). Using a Master/Slave configuration makes it
possible to record more traces without increasing the number of
vibrators, or to use two recording systems at two distinct places. The
Slave DSD is used in place of a DPG to control the slave recorder: it
generates a Time Break for the slave recorder to start the seismic
acquisition and also a reference pilot signal synchronous with the
Time Break. It does not control any vibrator.
For more details, see the VE464 DPG Users Manual.
Fleet Id
This field is used to specify the identification number (1 to 32) of each
vibrator group to build.
Radio Nb
Because two TracsTDMA or Raveon radio boxes can be attached to the
DPG, you have to specify which one to use for communications with the
DSDs included in this fleet, by entering either 1 or 2 in this field.
The Enable TDMA Tracking Mode option from the right-click menu
in the jPositioning window will show the DSDs associated with
TDMA #1 in blue, and those associated with TDMA #2 in orange.
VE464
The Vibrator Crew setup >
500 428XL Users Manual Vol. 1
April 11, 2013
9
DSD Network
This button is used to specify whether a DSD network is implemented
and enable the Navigation-driven shooting (page 309) mode. The DSD
network allows each DSD in a fleet to communicate with the fleets
leader via an Ethernet wireless datalink. As a result, when all the DSDs
in the fleet are ready for the next sweep, the fleet's leader is able to
supply the DPG with a Ready message containing the geographical
position of the Centre Of Gravity of the fleet, referred to as Source
COG. This allows the system to select the Source Point automatically
in the Operation window and display it in the Positioning main window.
Also, as only the Leader vibrator needs a time slot to transmit
messages from the whole fleet to the DPG, the capacity of the TDMA
datalink is used more efficiently, allowing a faster refresh rate to be
achieved. See VE464 Users Manual.
VE464
The Basic Type setup > Overview
428XL Users Manual Vol. 1 501
April 11, 2013
9
The Basic Type setup
In this section:
Overview (page 501)
Linear (page 503)
dB/Hz Log, Tn and dB/Octave Log (page 504)
Random (page 509)
Custom (page 510)
Dedicated (page 512)
Pulse (page 513)
Delay (page 514)
Compound (page 515)
The Deboost option (page 516)
The Numeric Pilot option (page 516)
Generating a Basic Type setup (page 517)
Overview
To open the Basic Type setup window, select Basic Type from
the Setups menu. Creating a Basic Type is the process of
describing a basic signal to be used:
- by the DSDs to generate sweeps for the vibroseismic source
(vibrator control signal),
- and/or by the DPG to generate up to 32 digital (or two analog)
Pilots to be used as reference signals for correlation
processors.
You can create up to 32 different Basic Types, which can be combined
using the Compound option.
Below are the allowable ranges for the entry fields that may appear in
the Basic Type setup window.
VE464
The Basic Type setup > Overview
502 428XL Users Manual Vol. 1
April 11, 2013
9
Start Taper 0 to 32000 ms.
End Taper 0 to 32000 ms.
The start and end tapers are used to reduce the side lobes appearing in
the correlation function of the sine wave or pulse. (The ratio of the peak
amplitude to the side lobes is a measure of the quality of the correlation
function).
Initial Phase -180 to +180.
Amplitude 0 to 100%.
Length 1 to 64 s (only for Random, Custom and Delay type
signals).
Ti 2 to 16 values from 0 to 64000 ms (T1 must be 0).
Tj 2 to 16 values from 0 to 64000 ms (T1 must be 0).
Ai 2 to 16 values from -40.00 to +40.00 dB.
Aj 2 to 16 values from 0 to 100%.
Fi 2 to 16 values from 1 to 300 Hz in increasing order
of frequency.
Frequency 1 to 300 Hz (only for Pulse type).
Each basic signal type can be composed of up to 16 segments (32 for
the dB/Hz Log and dB/Octave Log basic signals).
For details on each basic signal, see below.
See also The Numeric Pilot option (page 516).
VE464
The Basic Type setup > Linear
428XL Users Manual Vol. 1 503
April 11, 2013
9
Linear
You define a Linear-type signal through an analytic description. At the
signal start and end times, and possibly at particular times in between,
you have to specify:
the signal frequency (Hz),
the signal amplitude (% of requested drive level).
Figure 9-3
The Frequency variation vs. time is linear within each frequency
segment. Frequency segments are defined as follows:
The first Ti,Fi pair (T1,F1) specifies the initial frequency hence:
T1=0 sec., F1 =initial frequency.
The second Ti,Fi pair specifies the end time of the first segment (T2)
and the signal frequency at this time is F2, etc.
You must define at least two Ti,Fi pairs (i.e. one frequency segment).
Amplitude segments are defined as follows:
The first Tj,Aj pair (T1,A1) specifies the initial amplitude, hence:
T1=0 sec., A1 =initial amplitude.
Frequency
lines
Signal
amplitude
VE464
The Basic Type setup > dB/Hz Log, Tn and dB/Octave Log
504 428XL Users Manual Vol. 1
April 11, 2013
9
The second Tj,Aj pair specifies the end time of the first segment (T2)
and the signal amplitude at this time is A2, etc.
Within each amplitude segment, the amplitude variation vs. time is
linear.
The last Tj determines the total signal length. You must define at least
two Tj,Aj pairs (i.e. one amplitude segment).
Ti and Tj may be different both in number and value but the last Ti and
the last Tj must be the same value.
Note See also page 501.
dB/Hz Log, T
n
and dB/Octave Log
Note For non-linear sweeps, the slope in dB is the spectrum slope
before correlation, that is assuming the slope of the power
spectrum is NdB (N being the slope value programmed in the
Basic Type setup), the spectrum of autocorrelation will have a
2 NdB slope.
dB/Hz Log
You define a LOG-type signal through a spectral description, by
specifying;
- the amplitude (dB) of two or more frequency lines in the signal
spectrum,
- the signal amplitude (% of requested drive level) at the start and
end times and possibly at particular times in between.
The Frequency variation vs. time is logarithmic within each
frequency segment. This signal type is used to compensate for the non-
linear response of the ground (HF damping).
VE464
The Basic Type setup > dB/Hz Log, Tn and dB/Octave Log
428XL Users Manual Vol. 1 505
April 11, 2013
9
Figure 9-4
Each Fi,Ai pair defines a spectrum line at frequency Fi with amplitude
Ai. Fi,Ai pairs are listed in the increasing order of frequency. You must
define at least two spectrum lines. You can specify up to 32 frequency
segments.
Amplitude segments are defined as follows:
The first Tj,Aj pair (T1,A1) specifies the initial amplitude, hence:
T1=0 sec., A1 =initial amplitude.
The second Tj,Aj pair specifies the end time of the first segment (T2)
and the signal amplitude at this time is A2, etc.
Within each amplitude segment, the amplitude variation is linear.
You must define at least two Tj,Aj pairs (i.e. one amplitude segment).
The last Tj determines the total signal length. You can specify up to 32
amplitude segments.
Frequency
lines
Signal
amplitude
VE464
The Basic Type setup > dB/Hz Log, Tn and dB/Octave Log
506 428XL Users Manual Vol. 1
April 11, 2013
9
The Frequency is expressed as:
Where:
SegRa =Sb/Se =10
(-Ra/10)

Sb =Slope at the start of the log segment.
Se =Slope at the end of the log segment.
Fb =Start frequency.
Fe =End frequency.
T =Te-Tb =Basic signal length.
Rarepresents the attenuation (in dB) within the signal spectrum.
Example:
Ra=10 - 5 =5
SegRa =0.316
Note Choose the Deboost option if the signal is to be used for
Deboost-type processing. See The Deboost option (page 516).
See also page 501.
Delta dB values
Fi (Hz) Ai (dB)
8 5
80 10
|
|
.
|

\
|
+
|
|
.
|

\
|

+ = ) 1
1
( 1 log
1
log
) (
SegRa T
t
SegRa
Fb Fe
Fb t Fi
VE464
The Basic Type setup > dB/Hz Log, Tn and dB/Octave Log
428XL Users Manual Vol. 1 507
April 11, 2013
9
dB/Octave Log
Figure 9-5
The Ti,Fi fields are used to specify the frequency at the start time and
at the end time (two Ti,Fi pairs are required). A single frequency
segment is allowed.
The Tj,Aj fields are used to specify the amplitude (% of requested drive
level) at the start time, at the end time and, if required, at particular
times in between (at least two Tj,Aj pairs are required). The last Tj
determines the total signal length. You can specify up to 32 amplitude
segments.
The Slope dB/Octave field is used to specify the slope in dB/oct of the
signal spectrum (SdB in the expression below).
The Frequency is expressed as:
Frequency
lines
Signal
amplitude
n
SdB
3
---------- 1 + =
Fi t ( ) Fb
n t
T
--- Fe
n
Fb
n
( ) +
1
n
---
=
VE464
The Basic Type setup > dB/Hz Log, Tn and dB/Octave Log
508 428XL Users Manual Vol. 1
April 11, 2013
9
T
n
Same as dB/Hz Log type (with no Deboost option), except for the
frequency variation which is exponential rather than logarithmic.
Figure 9-6
The Frequency is expressed as:
Frequency
lines
Signal
amplitude
( )
n
n n n
Fb Fe
T
t
Fb t Fi
SegRa
Fb
Fe
Fb
Fe
n
(
(

|
|
.
|

\
|
+ =

|
.
|

\
|
|
.
|

\
|
=
1 1 1
) (
log log
log
VE464
The Basic Type setup > Random
428XL Users Manual Vol. 1 509
April 11, 2013
9
Random
Figure 9-7
The Random basic signal type allows you to take sweeps that do not
generate resonant frequencies (e. g. the resonant frequencies of
buildings) and also allows two or more vibration sources to be used
simultaneously with minimum interference. The Random type
generates a Pseudorandom noise signal based on one of the four
different polynomial sequences selectable from the Polynomial
option button:
65spoly1: first polynomial with 65535-ms sequence length
65spoly2: second polynomial with 65535-ms sequence length
8spoly1: first polynomial with 8191-ms sequence length
8spoly2: second polynomial with 8191-ms sequence length
The two 8-second polynomial options should only be used with
listening times less than 8 seconds. The polynomial sequences have
been appropriately designed for minimum cross-correlation residual.
VE464
The Basic Type setup > Custom
510 428XL Users Manual Vol. 1
April 11, 2013
9
You define a Random-type basic signal by specifying:
the polynomial option,
the amplitude (dB) of two or more frequency lines in the spectrum,
the signal length (duration), and start and end tapers.
Frequency segments should be defined as follows:
- The first Fi,Ai pair specifies the initial frequency (F1) and the
initial amplitude (A1). F1 must be 5, 7, 10, 14 or 20 Hz.
- The second Fi,Ai pair specifies the frequency (F2) and the
amplitude (A2) of the signal at the end of the first segment, etc.
You must define at least two Fi,Ai pairs (i.e. one frequency
segment).
Note Choose the Deboost option if the signal is to be used for
Deboost-type processing.
See also The Deboost option (page 516).
Custom
The Ve464 allows you to define a large variety of different sweeps
(Linear, Logarithmic, T
N
, Pulse, Random, Compound). You may
however need to use special (Custom) sweeps other than those pre-
determined by the VE464. To create a Custom sweep, you have to use
a tool of your own to create an ASCII text file containing all the samples
required to depict the signal.
For the GUI to be able to select a Custom sweep, you not only have to
load it to DSDs (see the VE464 Users Manual to do that) and to the
DPG (see Update Custom on page 548), but you also have to use this
setup window to create a list of your Custom sweeps.
VE464
The Basic Type setup > Custom
428XL Users Manual Vol. 1 511
April 11, 2013
9
Figure 9-8
The Custom Id field is used to enter the identifier name of the custom
sweep file that is or will be stored in the DPG and in the DSDs. (For
your custom sweep file to be interpretable by the VE464, it must include
an Identifier tag with a name behind that tag).
Unless that file is present in the DPGs memory when you launch the
Set DSD function to upload sweep parameters to the DSDs, a warning
will appear to remind you that you must load that file with the Update
Custom (page 548) function.
The signal length is displayed for your information, in the Length field
(this may be helpful if you plan to use this signal in a Compound
sweep). After entering an identification number (and possibly a label),
click Add to save the Custom sweep identifier to the list.
VE464
The Basic Type setup > Dedicated
512 428XL Users Manual Vol. 1
April 11, 2013
9
Dedicated
You may want to program the VE464 specifically, not to have all the
vibrators doing the same sweep. This Setup window allows you to
choose a sweep type for the DPG and different sweep types for DSDs.
Figure 9-9
First you have to use one of the other tabs (Linear, Log, etc.) to create
as many Basic Signal Types as required. Then click on the Dedicated
tab and do the following:
In the DPG Basic Type Nb field, enter the Basic Type Number of
the signal you want the DPG to generate.
For each DSD in the source, the DSD Nb field is used to specify
the position number of the vibrator in the source pattern, which
should not be mistaken for the DSD identification number. For
example, enter 1 if this is the first vibrator in the pattern. See The
Pattern setup window (page 532). In the Basic Type Nb field, enter
the Basic Type Number of the signal you want the DSD to generate.
Click the Add button associated with the upper list box, and do the
same until each DSD in the source pattern has the appropriate Basic
Type Number in the list box.
To save your settings, click the Add button (or Change, as required)
associated with lower list box.
VE464
The Basic Type setup > Pulse
428XL Users Manual Vol. 1 513
April 11, 2013
9
Note You do not need to change your Dedicated Setup settings if you
replace any vibrator with a spare one (this Setup window is
affected by changes in the source pattern, not by changes in
DSDs).
Pulse
Figure 9-10
Two parameters are needed to define a pulse-type signal:
- a frequency (F) that determines the pulse width (T) as:
T =1/F
- an amplitude (% of requested drive level).
A 1-second signal is generated, with the pulse peak centred at
0.5second.
0
-0.5
-1
0 100 200 300 400 500 600 700 800 900 1000
T
Time (ms)
VE464
The Basic Type setup > Delay
514 428XL Users Manual Vol. 1
April 11, 2013
9
A Pulse-type signal is needed for two purposes:
Checking the polarity of the devices in the system.
In operation, pulse reflection from shallow layers of the ground.
Delay
Figure 9-11
The Delay basic signal type uses a single entry field (Length,
allowable range 1 to 64 s).
If you wish to delay any basic signal, specify the desired delay time in
the Length field. In the lower pane, enter a new number and label and
click Add then Apply. Then use the Compound tab to create a new
basic type including that delay. See Compound (page 515).
VE464
The Basic Type setup > Compound
428XL Users Manual Vol. 1 515
April 11, 2013
9
Compound
Figure 9-12
The Compound basic signal type allows you to create a basic sweep
signal composed of a combination of two or more basic types. You just
have to enter the number of each of those basic types needed into the
Basic Type field and click Add in the upper pane. In the lower pane,
enter a new number and label and click Add then Apply.
You can use this option to define a signal including a delay time: create
a delay type with the desired delay length, using the Delay option, then
insert it where you would like it to appear in the Compound sweep.
The total length should not exceed 64 seconds.
Note The signals will be generated in the order determined in the list
box.
VE464
The Basic Type setup > The Deboost option
516 428XL Users Manual Vol. 1
April 11, 2013
9
The Deboost option
If you choose the Deboost option for Log or Random type signals, the
428XL will make the necessary computation for the frequency
spectrum shape of the output signals to be the same as that of a linear
sweep.
Figure 9-13
Note Whether or not the Deboost option is enabled, the VE464
generates the same sweep. This option does not affect the
behaviour of the VE464.
The Numeric Pilot option
When the system supplies the basic sweep table to the DPG (a table
containing the description of the basic sweep signals to generate) the
DPG calculates the required numeric values for reference samples. It
can save them as Numeric Pilots to files on the recorders server
computer so that the recorder can use the samples from those files
where correlation of the seismic data with the pilot signal is requested.
Therefore the system does not need to record any analog pilot on the
auxiliary line (analog pilots are used however if the DPG is attached to
a recording system other than a 428XL).
For each basic signal type you create, you have to tick or untick the
Numeric Pilot option to specify whether or not that signal must be
saved as Numeric Pilot so that it can be used as reference in
correlation processes.
In the SEGD file, auxiliary traces containing a Numeric Pilot are
distinguished from analog auxiliary signals by Trace Header Extension
block #6 (Byte 1 is set to 0x20). See Users Manual Vol. 2.
You cannot use the Numeric Pilot option with a 0.25-ms Sample Rate.
VE464
The Basic Type setup > Generating a Basic Type setup
428XL Users Manual Vol. 1 517
April 11, 2013
9
Generating a Basic Type setup
The Basic Type setup window allows you to define up to 32 different
basic signal types.
1. Click on the appropriate tab, depending on which mathematical
function you wish to use.
2. In the upper pane, set the parameters as required.
3. In the lower pane:
- The list box shows the list of basic signals already defined, if
any.
- The Number field is used to enter or display a basic signal type
number. Example: 25 refers to basic signal #25 (bas25 in the
list box).
- The Label field is used to enter or display a more user-friendly
label for the basic signal type. The default label refers to the
mathematical function selected for the basic signal.
- The basic signal #displayed in the Number field and defined
with the selections made in the upper pane is added into the list
box when you click the Add button (unless it is already defined).
If you double-click any basic type in the list box, then its characteristics
appear in the upper pane. To make changes, click it in the list box, make
the desired changes and click Change or Delete. Clicking Apply saves
your changes.
Any changes to the Basic Type currently used will not be effective until
you use the Set DSD function to initialize the DSDs.
VE464
The Acquisition Type setup >
518 428XL Users Manual Vol. 1
April 11, 2013
9
The Acquisition Type setup
Figure 9-14
The Acquisition Type setup supplies the following information to the
DSDs in a vibrator fleet:
- For each Acquisition Type, the upper pane contains the attributes
of each fleet to use, specifying which sweep signal the DSDs
must generate (two or more fleets can shake simultaneously, not
generating the same sweep signal). Also, for each fleet, you can
choose two signals as Numeric pilots to be available for
recording as auxiliary traces, and available as reference signal
for a correlation processing of seismic channels.
- In the lower pane is the list of Acquisition Types created, with
two job options for each of them (baseplate automatic lift, and
synchronization with a 50 or 60 Hz signal);
Acquisition Type & Label
The Acquisition Type field is used to enter an identification number
(1to 32) for the Acquisition Type. You will need that identification
number when you create a Process Type in the Operation window
(see The Process Type setup on page 256).
The Label field is used to enter a label (up to 16 ASCII characters) for
the Acquisition Type. A default label is prompted by the system (acq
type #) but you can enter a more user-friendly one.
1 1 1 2
1 1 1 2
1 3 3 4
VE464
The Acquisition Type setup >
428XL Users Manual Vol. 1 519
April 11, 2013
9
Note A noise elimination Threshold Type (modulo 16) is
automatically associated with each Acquisition Type:
Threshold Type 1 <=> Acq Type 1
Threshold Type 2 <=> Acq Type 2
... ...
Threshold Type 16 <=> Acq Type 16
Threshold Type 1 <=> Acq Type 17
... ...
Threshold Type 16 <=> Acq Type 32
Fleet Number
This field is used to specify the identification number of the fleet to
associate with this Acquisition Type, to be selected from those created
in the The Vibrator Crew setup (page 498). If you want to control two or
more fleets simultaneously, create a row for each of them in the lower
list box.
Basic Type Nb
This field tells the DSDs which sweep signal to generate. Enter one of
the Basic Type numbers created using The Basic Type setup on
page 501).
Correl with
This field allows you to choose a signal (by entering one of the Basic
Type numbers created using The Basic Type setup on page 501) to be
associated as digital pilot with this fleet. As a result, if the keyword
correlWith appears in the description of an auxiliary trace (Figure 6-13
on page 261) or correlation of seismic channels (Figure 6-17 on
page 265), then the system will automatically replace the keyword by
this signal where appropriate.
VE464
The Acquisition Type setup >
520 428XL Users Manual Vol. 1
April 11, 2013
9
This also causes the selected signal to be available on the DPGs Analog
Pilots connector (only intended for other recording systems than the
428XL).
Add (additional) Pilot
This field allows you to choose an additional signal (by entering one of
the Basic Type numbers created using The Basic Type setup on
page 501) to be associated as digital pilot with this fleet. As a result, if
the keyword addPilot appears in the description of an auxiliary trace
(Figure 6-13 on page 261) or correlation of seismic channels (Figure 6-
17 on page 265), then the system will automatically replace the keyword
by this signal where appropriate.
This also causes the selected signal to be available on the DPGs Analog
Pilots connector (only intended for other recording systems than the
428XL).
Auto Lift
Select this option if you wish the vibrator baseplate to automatically lift
at the end of the sweep depicted by the acquisition type. The baseplate
will not lift automatically, however, unless and until the Auto Lift
button on the DSD is activated too.
High Line Sync
The High Line Sync function is used to remove the noise radiated by
nearby power lines, by means of the following technique:
- The system generates a 50 or 60 Hz signal, depending on which
option you choose.
- The sweeps are ALTERNATIVELY triggered on the positive-
going and then on the negative-going transitions of the 50 or
60Hz signal.
- With an even number of sweeps, any high line noise picked up
by the receivers is theoretically removed through the stacking
process.
VE464
The Acquisition Type setup >
428XL Users Manual Vol. 1 521
April 11, 2013
9
Note High Line synchronization is irrelevant for a pseudo-random
signal.
By clicking on the option button, you can choose between three options:
Free: no synchronization;
50 Hz: the system generates a 50 Hz signal, and the T0 time is
alternately synchronized on the low-to-high and then on the
high-to-low transition of that signal;
60 Hz: the system generates a 60 Hz signal, and the T0 time is
alternately synchronized on the low-to-high and then on the
high-to-low transition of that signal.
To create a new acquisition type, enter its number in the Acquisition
Type field, select the desired options and signals, and then click Add.
To make changes, click it in the list box, make the desired changes and
click Change or Delete as required.
To save the current list of acquisition types, click Apply. (To revert to
the former list, click Reset instead).
VE464
The Radio Management setup > TDMA
522 428XL Users Manual Vol. 1
April 11, 2013
9
The Radio Management setup
In this section:
TDMA (page 522)
TracsTDMA (page 523)
Raveon (page 526)
Analog radio (page 528)
TDMA
The Time Division Multiple Access (TDMA) channel access method
allows several users to share the same frequency channel by dividing
the signal into different time-slots. The DPG and the DSDs transmit in
rapid succession, one after the other, each using its own time-slot. This
allows the DSDs to share the same radio frequency channel while using
only the part of its bandwidth they require. As a result, unlike with a
conventional radio which may delay messages by a few seconds, if
TDMA is used the messages between the DPG and all the DSDs are
virtually simultaneous.
From the Type Of Radio dropdown list, choose TracsTDMA or
Raveon, depending on which type of radio you want to use for
communications between the DPG and the DSDs.
If you are reading this manual on-line, you can calculate the impact of
of radio parameters on the FO-to-TB delay by clicking this link:
TracsTDMA or Raveon.
VE464
The Radio Management setup > TracsTDMA
428XL Users Manual Vol. 1 523
April 11, 2013
9
TracsTDMA
Figure 9-15 TracsTDMA setup
GPS Correction:
- No correction: straight GPS is used.
- Diff Uncompressed: Choose this option if you want a
TracsTDMA box to broadcast Differential GPS data (RTCM or
RTK), which requires a higher data rate, depending on the GPS
receiver used. This causes the system to automatically allocate
the necessary time slots to DGPS data. You have to specify the
required Correction rate (see below). For details, see the
VE464 manual.
- Correction rate: number of bits per second for the GPS
correction broadcast (200 to 2000 bits/s). The minimum required
depends on the type of GPS corrections (RTCM, RTK, etc.) and
on the type of receiver. Unless the Correction Rate is set to be at
least equal to the minimum required, the differential corrections
may fail to work.
Typical values are 200 bits/s for conventional differential
corrections and 1600 bits/s for RTK.
If you are reading this manual on-line, you can calculate the
necessary TracsTDMA time slots by clicking here.
Nb Of Tracs: used to specify the number of TracsTDMA systems
attached to the DPG. Typically, a single TracsTDMA system is
VE464
The Radio Management setup > TracsTDMA
524 428XL Users Manual Vol. 1
April 11, 2013
9
required, but you may want to use a second one for a higher
recurrence rate of each DSDs message.
Tracs power: used to set the output power of the TracsTDMA box
(10 mW, 500 mW, 2 W, 10 W). Typically, the output power is set to
10 W.
Channel: used to select the Channel number (1 to 9) to use on the
TracsTDMA system, depending on which channels are available (to
create a frequency channel on the TracsTDMA box itself, see the
VE464 manual). If two TracsTDMA boxes are attached to the DPG,
choose a different channel for each.
Baud rate: this option button allows you to set the Baud rate for the
TDMA datalink on the TracsTDMA box or boxes attached to the
DPG.
The Baud rate options for the TDMA datalink range from 4800 to
14400. The default setting is 12000. You can change this setting but
it is important to consider the impact of your changes and remember
the Baud rate must be the same on all TracsTDMA boxes (on the
DPG and all DSDs).
See What is the impact of a higher or lower baud rate? in the VE464
manual.
If you are reading this manual on-line, you can calculate the
necessary TracsTDMA time slots by clicking here.
Base Id: in the Base Id 1 field, enter the identification number (001
to 254) of the TracsTDMA box attached to the DPG. (To set the
identification number on the TracsTDMA box itself, see the VE464
manual).
If a second TracsTDMA is attached to the DPG, enter its
identification number into the Base Id 2 field. It is for the user to
ensure the ID number of each TracsTDMA box within the crew is
unique.
Tracking: choose this option if you want DSD positions to be
available from the DB25 Data connector on the TracsTDMA box
VE464
The Radio Management setup > TracsTDMA
428XL Users Manual Vol. 1 525
April 11, 2013
9
attached to the DPG. This option causes the TracsTDMA system to
automatically allocate a time slot to conveying a DSDs position
towards the DPG. For details, see Vehicle Tracking in the VE464
manual.
Note that regardless of whether or not this option is selected, DSD
positions are displayed in the Positioning window.
Repeater: to increase the radio range, you may want to use a
TracsTDMA repeater (rather than decrease the baud rate). Choose
None if no repeater is used on this TracsTDMA channel, otherwise
select the appropriate type of repeater:
- A Single-Frequency repeater uses the same frequency channel
as the TracsTDMA box (therefore a complete cycle for the
transmission of all DSD messages requires twice as many time
slots).
- A Dual-Frequency repeater uses another frequency channel for
relaying the DSD messages and so takes up only two extra time
slots. With the no scan option, each DSD must be set
manually to talk to the DPG or the repeater, and the Vibrator
Fleet function must be used whenever that setting is changed.
With the scan option, each DSD scans for the strongest radio
signal and automatically chooses to talk to the DPG or to the
repeater with no need to use the Vibrator Fleet function. For
details, see the VE464 manual.
GPS Base Position: the GPS Base Position button opens a
secondary setup window that lets you enter the coordinates of the
GPS antenna if the TracsTDMA box is used as DGPS reference
station.
VE464
The Radio Management setup > Raveon
526 428XL Users Manual Vol. 1
April 11, 2013
9
Figure 9-16
- Latitude: degrees (2 digits), minutes (2 digits), seconds (2
digits), fractional part of second, with a minus sign if South.
- Longitude: degrees (3 digits), minutes (2 digits), seconds (2
digits), fractional part of second, with a minus sign if West.
- Elevation: altitude +geoidal separation (metres).
Different messages may appear as you click on Go (see the VE464
Users Manual).
Raveon
Figure 9-17 Raveon setup
GPS Correction: tick this option if you want to broadcast RTCM or
RTK Differential GPS corrections through the Raveon box. This
causes the system to automatically allocate the necessary time slots
to the Differential GPS data. You have to specify the required
Correction rate (see below). For details, see the VE464 manual.
VE464
The Radio Management setup > Raveon
428XL Users Manual Vol. 1 527
April 11, 2013
9
Correction rate: number of bits per second for the GPS correction
broadcast (200 to 2000 bits/s). The minimum required depends on the
type of GPS corrections (Differential, RTK, etc.) and on the type of
receiver. Unless the Correction Rate is set to be at least equal to the
minimum required, the differential corrections may fail to work.
Typical values are 500 bits/s for conventional differential corrections
and 1000 bits/s for RTK.
If you are reading this manual on-line, you can calculate the
necessary time-slots by clicking here.
Nb Of Raveon: used to specify the number of Raveon boxes attached
to the DPG. Typically, a single Raveon box is required, but you may
want to use a second one for a higher recurrence rate of each DSDs
message.
Power Tx(%): used to set the output power of the Raveon box (100%
stands for 5 W).
Channel: used to select the Channel number (1 to 6) to use on the
Raveon radio, depending on which channels are available (to create a
frequency channel on the Raveon box itself, see the VE464 manual).
If two Raveon boxes are attached to the DPG, choose a different
channel for each.
Baud rate: this option button allows you to set the Baud rate for the
airlink on the Raveon box or boxes attached to the DPG.
Two Baud rate options are available: 4800 and 9600. The default
setting is 9600. You can change this setting but it is important to
consider the impact of your changes and remember the Baud rate
must be the same on all Raveon boxes (on the DPG and all DSDs).
See What is the impact of a higher or lower baud rate? in the VE464
manual.
If you are reading this manual on-line, you can calculate the
necessary time-slots by clicking here.
Repeater: to increase the radio range, you may want to use a Raveon
repeater (rather than decrease the baud rate). In that case, click the
VE464
The Radio Management setup > Analog radio
528 428XL Users Manual Vol. 1
April 11, 2013
9
Repeater option, and if you want to allow repeaters to be cascaded,
use the Repeater Levels dropdown list to select the desired
maximum number of repeater levels (1 if no cascading).
Different messages may appear as you click on Go (see the VE464
Users Manual).
Analog radio
Choose Analog from the Type Of Radio button if a conventional
analog radio is used for communications between the DPG and the
DSDs.
Figure 9-18
This setup window allows you to set the transmission power level of the
radio units remotely.
The Radio Level is adjustable from 3% (min) to 100% (max).
Radio Transmission Delay: set as required, depending on the radio
model used (see VE464 Users Manual).
If you are reading this manual on-line, you can calculate the impact of
of radio parameters on the FO-to-TB delay by clicking this link:
Analog.
VE464
The QC Limit setup >
428XL Users Manual Vol. 1 529
April 11, 2013
9
The QC Limit setup
Figure 9-19
This dialog box allows you to set alert thresholds for some of the
Quality Control data supplied to the GUI by the DSDs. Any threshold
being overridden will cause the QC data of the DSD to be displayed in
orange in the main window.
Average Phase Error: Maximum limit (0 to 45 degrees).
Maximum Phase Error: Maximum limit (0 to 45 degrees).
Average Distortion: Maximum limit (0 to 50%).
Maximum Distortion: Maximum limit (0 to 80%).
Average Ground Force: Minimum limit (0 to 100%).
To save and enable your changes, click Apply. (To revert to the former
settings, click Reset instead).
VE464
The Sweep Management setup >
530 428XL Users Manual Vol. 1
April 11, 2013
9
The Sweep Management setup
Figure 9-20
To save and enable your changes, click Apply. (To revert to the former
settings, click Reset instead).
Number of T
0
WARNING
Increasing this parameter will increase the delay time between the
Firing Order and the Time Break. See the Sweep Start Timing Diagram
in the VE464 Users Manual.
In the event of difficult radio transmission conditions (important
interference or jamming), increasing the number of T
0
data words
transmitted may give the DSDs a better chance to receive them. The
down side is a possible waste of time as this increases the time delay
between the FO and the TB.
If you are reading this manual on-line, you can calculate the impact of
the number of T
0
data words on the FO-to-TB delay by clicking either
of these links, depending on which type of radio is used: Tracs TDMA
or Raveon or Analog.
Data Computation Domain
(Time or Frequency) This option button is used to specify whether
the DPG should output the vibrator QC data in the Time domain (phase
error, distortion, ground force) or in the Frequency domain (phase
error, ground force).
VE464
The Sweep Management setup >
428XL Users Manual Vol. 1 531
April 11, 2013
9
Extended QC
If you select this option, QC data can be viewed in real time (i. e. with
Auto activated), using the Get QC function. The average QC results
computed over a complete acquisition are still available.
If the Time domain is selected, the QC is data computed every
0.5second.
If the Frequency domain is selected, the QC is data computed
every 2.5Hz.
(If you do not select the Extended QC option, the Extended QC data is
still computed but it cannot be viewed during acquisitions).
Get DSD Status
This option button allows you to choose the moment when each DSD
should transmit its status to the DPG.
With TDMA datalinks, the recommended setting for this option is
During the sweep, because this is typically the fastest method (the
DSD will transmit its status during the next sweep rather than in the
interval between two successive sweeps). In the event of difficult radio
transmission conditions (important interference or jamming), you can
try the At end of sweep option (this causes each DSD to transmit its
status only in the interval between sweeps, but this may be the fastest
method if too many retries are required).
With analog radio links, the At end of sweep option lets you see the
status from each DSD earlier. The During the sweep option allows
you to have shorter intervals between sweeps (the system does not have
to wait until the status from each DSD is received).
VE464
The Pattern setup window >
532 428XL Users Manual Vol. 1
April 11, 2013
9
The Pattern setup window
The pattern setup window allows you to define the geometry of a
Vibrator Point, by specifying the position of each vibrator with respect
to the Centre Of Gravity of the source point. The pattern description is
required for the Guidance function.
Figure 9-21
To generate a pattern description, do the following:
1. Use the Pattern Nb option button to choose an identification
number for the type of pattern.
2. Use the Nb of Vib option button to specify the number of
vibrators in the pattern.
3. Adjust the position of each vibrator in the pattern as required, by
dragging the vibrator point in the graphic view or specifying the
appropriate delta X and delta Y offset with respect to the
Drag to adjust
Vib position
Numeric description
of pattern
Number of vibrators
in pattern
Pattern type
identification
number
Planned
source COG
Metres
or Feet
Graphic view of
pattern
1
2
3
4
p1 p2
p4 p3
0.5
-0.5
-0.5
0.5
0.5
0.5
-0.5
-0.5
VE464
The Pattern setup window >
428XL Users Manual Vol. 1 533
April 11, 2013
9
planned COG, in metres or feet (you can select whichever you like
from the Unit button).
4. Set the rotation and source line parameters:
Pattern rotation: (dddmmss.ss) use this field to rotate the pattern as
required. (The vertical axis of the pattern in the graphic view always
points to the true North).
Figure 9-22
Stack distance: distance to the next shake location within a stacked
VP, for each vibrator (i. e. source station spacing).
(-0600000.00)
-60
p1
p2
p4
p3
p1
p2
p4
p3
(0450000.00)
45
-60
45
p1
p4
p3
p2
p1
p2
p4
p3
VPn VPn+1
VPn
VPn+1
(0450000.00)
45
p1
p2
p4
p3
45
p1
p2
p4
p3
VPn+1
VPn
True North
VP geometry
Pattern
Rotation
Pattern
Setup
True North
VE464
The Pattern setup window >
534 428XL Users Manual Vol. 1
April 11, 2013
9
Figure 9-23
With an even stacking fold, the VP is located midway (half the stack
distance) between the two centremost source stations as shown
below.
Figure 9-24
Stack Source Line Bearing: Bearing of the direction in which to
steer each vibrator to its next shake location within a stacked VP.
See the examples below.
12 m
VPn
12 m
Stack distance: 12 m , Stacking fold: 3
Source
Line
6 m
12 m 12 m
6 m
VPn
Stack distance: 12 m , Stacking fold: 4
Source
Line
VE464
The Pattern setup window >
428XL Users Manual Vol. 1 535
April 11, 2013
9
Figure 9-25
Figure 9-26
p1
p2
p4
p3
45
p1
p2
p4
p3
12 m
90
p1
p2
p4
p3
p1
p2
p4
p3
VPn
VPn+1
Pattern Rotation: 45, Stack Source Line Bearing: 90, Stack distance: 12 m , Stack fold: 2
True North
Source
Line
Stack
distance
1
2

m
p1
p2
p4
p3
-60
p1
p2
p4
p3
45
p1
p2
p4
p3
p1
p2
p4
p3
VPn+1
V
P
n
+
1
V
P
n
Pattern Rotation: -60, Stack Source Line Bearing: 45, Stack distance: 12 m , Stack fold: 2
True North
VE464
Functions > Auto/Manual
536 428XL Users Manual Vol. 1
April 11, 2013
9
Functions
In this section:
Auto/Manual (page 536)
Vibrator Fleet (page 537)
Local Acquisition (page 552)
Set DSD (page 541)
Get DSD (page 543)
Ready (page 550)
Set Servo (page 545)
Update Custom (page 548)
Set Config (page 553)
Set Guidance (page 554)
Get Similarities (page 555)
Update Version (page 557)
Auto/Manual
Figure 9-27
Clicking Manual isolates the DPG from the 428XL and enables its
local functions (e.g. local acquisition). As a result:
data acquisition in vibroseismic operations is suspended until the
DPG is reset to Auto.
the traffic light of the DPG in the 428XL Activity window turns red.
VE464
Functions > Vibrator Fleet
428XL Users Manual Vol. 1 537
April 11, 2013
9
Clicking Auto connects the DPG to the 428XL (and checks the DSD
Setup parameters) allowing it to perform data acquisition (if the VE464
window is ready, with consistent parameter settings, and if the Vib Fleet
function has been completed). With Auto activated, DPG local
functions are inhibited; the traffic light of the DPG in the 428XL
Activity window is green during sweeps, orange otherwise.
Vibrator Fleet
A crew may consist of up to 32 groups of DSDs referred to
as fleets (one fleet for each vibratory source). The Fleet
function is used to specify which DSDs each fleet includes.
Clicking the Fleet button opens a dialog box with a list box for each
fleet in the crew. (To specify which fleets are to be used in the crew, see
The Vibrator Crew setup on page 498).
Note that if you are using a TracsTDMA radio repeater between the
DPG and DSDs, with the Dual-Frequency, no scan option you may
have to change the Frequency channel setting on a DSD, as the source
moves. In that case you have to use the Fleet function each time you
change the Frequency channel manually.
Prerequisites
You must have used the Setup menu's Crew command to create a
crew (a list of DSDs) and describe the fleets to use.
Unless already done, click the Manual button in the control panel to
isolate the DPG from the recording unit. Note that if you do not want
to go to Manual, for example because you do not want to stop
production, only vibrator replacement within existing fleets is
allowed. See About the Update button (page 539) for details.
All the DSDs you want to address must be in the Remote state (press
the Remote key on the DSD).
You cannot use the Fleet function or button (i. e. it is dimmed) until
the DPG is connected to the computer and powered up
(communication between the two must be established).
VE464
Functions > Vibrator Fleet
538 428XL Users Manual Vol. 1
April 11, 2013
9
Building your vibrator fleets
Figure 9-28
The left-hand list box (DSDs) prompts the list of DSDs available to the
crew but not assigned to any fleet yet. Using the right arrow button (or
the usual Drag and Drop method), move the vibrators you want to
incorporate into a fleet from the left-hand list box to the desired fleets
list box.
The first vibrator (DSD) you enter into a fleets list box is assigned to
Position 1 in each source pattern, the second to Position 2, etc. In the
above example, Vibrator No. 3 is assigned to Position 2 in each pattern,
Vibrator No. 2 is assigned to Position 1. See The Pattern setup window
(page 532).
If you want to implement a wireless DSD network, you have to
specify which DSD is the Leader in the fleet. Double-clicking on any
DSD in the list enables or disables the use of the Ready button on this
DSD, and also determines which vibrator is the Leader. (An R
appears after the DSD number and position of the leader in the list box,
meaning that the use of the Ready button on this DSD is enabled).
Pushing the Ready button on any DSD is of no effect unless the button
is enabled in the Fleet window.
After selecting (highlighting) the desired DSDs in each fleet's list box,
clicking Go will update the status bar displayed under the function
buttons in the main window: a flag appears ahead of each vibrators fleet
in the status bar.
DSD Id
Number
Leader
Radio box used
Position in
Pattern
VE464
Functions > Vibrator Fleet
428XL Users Manual Vol. 1 539
April 11, 2013
9
Figure 9-29
Those vibrators which are ready in each fleet are shown in green.
If parameters need to be updated in any DSD, this DSD is shown in
blue and the message DSD#.. Wrong setup DSD table appears.
(Use the Set DSD function to load the parameters).
If the Installation or Initialization routine needs to be performed on a
DSD, this DSD is shown in red.
If any DSD fails to respond, it remains colourless (and it is shown in
regular rather than boldface characters in the Vib Fleet dialogue box).
About the Update button
Whether in Auto or Manual mode, the Update button at the foot of
the Fleet window allows appending, removing, or replacing one or more
vibrators without affecting the other fleets. You do not have to click Go
(anyway, in Auto mode the Go button is dimmed).
Note that The Vibrator Crew setup (page 498) determines which
TracsTDMA or Raveon box is used by which fleet, and only the Fleet
function (clicking on Go rather than Update) determines how many
TDMA time-slots are required for communications with the DSDs in
each fleet. Therefore the Update button works as follows, for each
TracsTDMA or Raveon box:
You cannot use Update to increase how many fleets (each including
one or more vibrators) are controlled by a TracsTDMA or Raveon
box, nor to increase the total number of vibrators used in the whole
set of fleets controlled by that TracsTDMA or Raveon box. For
example, assuming you have 5 fleets and the Fleet function assigns 2
The vibrator status bar in the
main window is updated
The green colour means the
vibrator is ready to be used in
remote control mode
VE464
Functions > Vibrator Fleet
540 428XL Users Manual Vol. 1
April 11, 2013
9
of them (each including one or more vibrators) to Tracs1 (or
Raveon1), and the other 3 to Tracs2 (or Raveon2). If, for any reason,
you want to swap Tracs1 (or Raveon1) for Tracs2 (or Raveon2), you
cannot use Update to do that, since Tracs1 (or Raveon1) is set to
control only 2 fleets.
Update can only be used to replace one or more vibrators (whether
or not the fleet is complete), or to add/remove one or more vibrators
if the fleet is incomplete. The vibrators that respond to the Update
function are shown in bold characters in the list box for the fleet (like
after a click on Go).
A fleet cannot be used for any acquisition unless and until it is
complete (that is, all the vibrators in the list should appear in bold
characters). Only those fleets in which all DSDs have responded (all
shown in bold characters) are visible to other functions such as
Set DSD, Set Servo, Get DSD, Get QC, etc. There is no way of
using these functions on any DSD that is part of a fleet in which one
or more DSDs failed to respond to the Update (or Fleet) function.
Advantages of using the Update function in Auto mode
To increase productivity, you can use the Update button in Auto
mode (rather than go to Manual and click on Go to launch the Fleet
function), for example:
to replace a vibrator by a spare one without stopping production;
or to begin production even though some fleets are not ready yet.
For example, assuming you launch the Fleet function in order to use
four fleets and this reveals only three are complete, you may well want
to begin production, and then you will use Update to include the fourth
fleet when it is ready, provided all DSD parameters are set properly
(remember in Auto mode you are not allowed to use such functions as
Set DSD, Set Servo, etc.).
Another example is illustrated below: Figure 9-30 shows the list box for
each fleet after clicking on Go (all DSDs in bold characters, except
DSD6 which failed to respond).
VE464
Functions > Set DSD
428XL Users Manual Vol. 1 541
April 11, 2013
9
Figure 9-30
In the above example:
The maximum number of fleets that can be controlled by Tracs1 is 3
(rather than 4). Therefore, you cannot use Update to assign any DSD
to Fleet4 unless and until two DSDs are removed from another fleet.
The maximum number of DSDs that can be used is 6 (rather than 5),
but if no change is made, only fleets #1 and #2 can be used (i. e. only
DSDs #1, #2, #3 and #4).
The Update button can, for example, be used to:
- update Fleet3 to try again DSD 6, or replace it by another
(unused) DSD, for example DSD 7;
- or update Fleet3 to remove DSD 5 and DSD 6 from it, and then
update Fleet4 to assign two DSDs to it (#7 and #8, or #5 and #6).
Set DSD
This function is used to upload sweep-type parameters from
the DPG to the DSDs you specify. It also uploads the
description of the source pattern.
The sweep parameters are read from the table containing all the
acquisition types (ACQ#) defined in the VE464 window. They are
required in the DSDs for generating the corresponding vibratory
sources. The Set DSD function allows you to have consistent
parameters in all the DSDs to be used for a sweep. Those DSDs which
have inconsistent parameters are shown in blue in the main window's
status bar.
DSD 7 DSD 1 p1
DSD 2 p2
DSD 3 p1
DSD 4 p2
DSD 5 p1
DSD 6 p2 DSD 8
VE464
Functions > Set DSD
542 428XL Users Manual Vol. 1
April 11, 2013
9
Prerequisites
Unless already done, click the Manual button in the control panel to
isolate the DPG from the recording unit.
You cannot launch this function until the Vibrator Fleet (page 537)
function has been used.
How to use the Set DSD function
1. Click the Set DSD pushbutton in the control panel. A dialog box
appears with a list box showing all the DSDs that responded to the
Vibrator Fleet function.
Figure 9-31
2. In the list box, select (by clicking) the vibrators you wish to load
parameters to.
3. Click the Go button.
Note With a customized basic signal (Custom option in Basic Type
setup), errors may appear at this stage as the Set DSD function
checks for consistent parameters from the custom file.
The green colour means
the DPG and DSD
acquisitions are matching
VE464
Functions > Get DSD
428XL Users Manual Vol. 1 543
April 11, 2013
9
Get DSD
This function is used to import and view vibrator parameters
(software version, results from Installation and Identification
routines, etc.) from one or more DSDs you specify.
Prerequisites
Unless already done, click the Manual button in the control panel to
isolate the DPG from the recording unit. You cannot launch this
function until the Vibrator Fleet (page 537) function has been used.
How to use the Get DSD function
1. Click the Get DSD button. A dialog box appears with a list box
showing the DSDs that responded to the Vibrator Fleet function.
Figure 9-32
2. In the list box, choose (by clicking) the vibrators you wish to get
parameters from.
3. Select the type of units you wish to use to display the results:
Metric (kg, daN, etc.) Imperial (lb, lbf, etc.).
4. Click the Go button.
After all the data from the DSDs have been collected they are viewed in
a table so that comparisons between DSDs can be made easily.
DSD parameters
Running the Get DSD function opens a view pane displaying the
following vibrator parameters from each selected DSD:
VE464
Functions > Get DSD
544 428XL Users Manual Vol. 1
April 11, 2013
9
Table 9-1 DSD parameters
Parameter Description
Serial#
Version
Host Id
Serial number.
Firmware version.
Sample rate
Filter Type
Line Filter Used
For archived vibrator motion signals.
Reaction Mass
Baseplate 1
Baseplate 2
Hold Down Weight
Hydraulic Force
100 to 32767 kg.
100 to 32767 kg.
100 to 32767 kg.
1000 to 327670 daN.
1000 to 327670 daN.
Mass Polarity
Valve Polarity
Torque Polarity
Polarity (depending on the wiring)
of the Reaction Mass, Servo Valve, Torque Motor.
Mass Back Gain
Valve Back Gain
- Gain of the Mass LVDT and
- Valve LVDT (Linear Variable Differential Transformer).
Mass offset
Valve offset
Torque offset
Mass Rated Stroke
- Reaction mass LVDT offset.
- Main Valve LVDT offset.
- Torque motor current.
- Active region of LVDT stroke, in percent.
Last Ident
Ident. name
Sweep1 Ident.
Sweep1 Result
Sweep2 Ident.
Sweep2 Result
Results from the two sweeps that were used for the identification
process.
Servo Gain
Servo Cut Freq.
Servo Damping
Oil Compres.
Oil Viscosity
Oil Leakage
Spool Gain
- Static gain of pilot valve.
- Pilot valve cut-off frequency.
- Pilot valve damping coefficient.
- Value of leakage between the two chambers of the reaction mass.
- Main valve static gain.
Exit. Ponderation
Min Gv
Servo Mode
Auto Level
High Drive
Low Drive
Min High Drive
Min Low Drive
- Gain weighting in the servo control loop.
- Minimum Ground Viscosity.
- Servo control type (Filtered or Raw).
- Auto Level use.
- Amplitude level (0 to 100%) for the DSD's DRIVE "H" key.
- Amplitude level (0 to 100%) for the DSD's DRIVE "L" key.
- If Auto Level =Yes, Minimum high drive level, in percent.
- If Auto Level =Yes, Minimum low drive level, in percent.
Pressure Switch
Dither
Analog Radio Level
- Pressure switch use.
- Mass control signal during idle periods of time.
- Transmission power if a traditional radio is used.
GPS RS232
GPS Status
VE464
Functions > Set Servo
428XL Users Manual Vol. 1 545
April 11, 2013
9
Set Servo
This function allows you to set the parameters used in each vibrator's
servo control loop. Clicking Go will set the servo control loop
parameters of all the vibrators you select (highlight) in the list box.
Figure 9-33
Prerequisites
Unless already done, click Manual in the control panel to isolate the
DPG from the recording unit.
Radio Id
Radio Serial Nb
Power (W)
Radio Frequency #1
Radio Frequency #2
Radio Frequency #3
Radio Frequency #4
Radio Frequency #5
Radio Frequency #6
Radio Frequency #7
Radio Frequency #8
Radio Frequency #9
Raveon Rssi Level
- TracsTDMA or Raveon identification number.
- TracsTDMA or Raveon serial number.
- TracsTDMA or Raveon transmission power.
Frequency of each TracsTDMA or Raveon channel
Mass Sensor
Plate1 Sensor
Plate2 Sensor
Status of accelerometers after installation
Table 9-1 DSD parameters (Continued)
Parameter Description
VE464
Functions > Set Servo
546 428XL Users Manual Vol. 1
April 11, 2013
9
You cannot launch this function until the Vibrator Fleet (page 537)
function has been used.
Servo Input
This option button determines what to use as input to the servo control:
either the estimated states from the Kalman filter (Filtered option) or
raw measurements of baseplate and mass accelerations (Raw option).
Filtered: using this option allows the system to discard non-coherent
measurements on any sensor (baseplate acc., mass acc., valve or mass
LVDTs). Remember that the QC and the usual way of testing the
equipment with external devices always involve the force derived
from raw acceleration measurements. Therefore, in the presence of
vibrator imperfections (e.g. mass rocking & baseplate flexure) a raw
QC can exhibit larger errors than the real performance of the servo
loop.
Raw: with this option, servo control and QC are homogeneous but
the system cannot benefit from the capability of discarding incorrect
measurements. This option is of no effect on a random sweep.
Auto Level
This button allows you to enable or disable the Auto Level function. If
you enable the Auto Level function, then you must specify lower limits
for both High and Low drive levels.
DSDs using the Auto Level function operate as follows:
The Drive level is decreased for the next sweep if an overload
condition is detected. However the drive level cannot go below the
values of Min High Drive and Min Low Drive.
The Drive level is increased for the next sweep if no overload
condition is detected. However the drive level cannot exceed the
values of High Drive Level and Low Drive Level.
DSDs not using the Auto Level function will operate only within the
limits of High Drive Level and Low Drive Level.
VE464
Functions > Set Servo
428XL Users Manual Vol. 1 547
April 11, 2013
9
Low Drive Level
Lower amplitude, in percent, of drive level. The scale is adjustable from
0 to 100% in 1% steps.
Requirements: Low Drive Level <High Drive Level.
High Drive Level
Upper amplitude, in percent, of drive level. The scale is adjustable from
0 to 100% in 1% steps.
Min Low Drive
This scale appears only if Auto Level is selected.
Low limit of Low Drive Level, in percent. The scale is adjustable from
0 to 100% in 1% steps.
Requirements: Min Low Drive <Low Drive Level.
Min High Drive
This scale appears only if Auto Level is selected.
Low limit of High Drive Level, in percent. The scale is adjustable from
0 to 100% in 1% steps.
Requirements: Min High Drive <High Drive level.
Lift Up Delay
Time interval between the end of a sweep and the moment when a
vibrator's pad will lift if Auto Lift is enabled. Adjustable from 0 to
99seconds.
If no delay is required, set the Lift Up Delay to 0.
Random
If you choose this option, then the delay for each vibrator in the fleet to
lift up its pad is variable from 0 to the value selected in the Lift Up
Delay field, meaning that not any two vibrators will lift up their pads at
VE464
Functions > Update Custom
548 428XL Users Manual Vol. 1
April 11, 2013
9
the same time. Not having vibrators lifting up their pads at the same
time results in less noise being generated and recorded.
Update Custom
This opens a window allowing you to display the list of Custom sweeps
stored in the DPG, and to update that list (you can delete some files and/
or add new ones). You can store a total Custom sweep length of up to
392 seconds (20 files max.) into the DPG. Note that this is a theoretical
allowable length and the actual available size may be lower as a result
of the internal organization of the Flash memory.
To see if the DPGs memory contains any Custom files, click the Get
button (the Update command is dimmed until you click Get).
Figure 9-34
For each Custom sweep file found in the DPGs memory, the list box
displays the Identifier field, the Comment field and the signal
length (seconds).
Removing a Custom sweep file
If you want to delete any file from the DPGs memory, click on it in the
lower list box and then click the Delete button. This only removes it
from the list. The file is not deleted until you click Update.
Clicking Erase will delete all Custom files from the DPGs memory (if
you confirm your choice in the warning box that shows up).
List of custom
sweep files
available for you to
load to the DPG
VE464
Functions > Update Custom
428XL Users Manual Vol. 1 549
April 11, 2013
9
Adding a Custom sweep file
To load a Custom sweep file, do the following:
1. From the Medium option button, choose either From USB (if
the file to load is located on a USB stick connected to the DPG),
of From directory if the file is stored on the client computers
disk.
- If you are loading from a USB stick (to be plugged in the DPGs
USB port), the file to load must be located in its root folder.
- Otherwise, use the Browse button to open the folder containing
the file to load.
2. Click on Scan to find the available custom sweep files. The
system searches the directory displayed in the Path field and
reads those files that have .custom as extension to the file name.
The Identifier field and the comments from those files are
displayed in the upper list box.
3. Select (click) the file to load and then click Add. As a result, the
file is added in the lower list box. (The file is not loaded to the
DPG until you click Update).
Updating the DPGs memory
After making sure you really want to load the files appearing in the
lower list box to the DPG, i. e. delete those you removed from the list
box, and/or load those you added into it, click Update.
VE464
Functions > Ready
550 428XL Users Manual Vol. 1
April 11, 2013
9
Ready
This function is used to upload radio management parameters to the
DPG and DSDs.
Figure 9-35
Number of Ready Frames
Typically, a single ready message is required. In the event of difficult
radio transmission conditions (important interference or jamming),
repeating the ready message may help.
Early Ready
WARNING
Using this option requires expertise and careful consideration.
A DSD is not normally allowed to generate a Ready message until the
pressure sensor says the vibrators pad is down. The Early Ready
option, however, allows the DSD to send its Ready message in
anticipation to make up for the communication time required between
the DSD and the DPG, and between the DPG and the GUI, for the T
0

data to be received by the DSD and the sweep to start.
Figure 9-36 Normal timing (no Early Ready)
Sweep
Pushing
Down
button
Pad is
down
Pressure
sensor
On
Ready
to
DPG
T
0

data
Wasted time
VE464
Functions > Ready
428XL Users Manual Vol. 1 551
April 11, 2013
9
Figure 9-37 With Early Ready Delay
The Early Ready Delay must be adjusted for the T
0
data to arrive right
after the pressure sensor switches On. If the T
0
data arrives before the
pressure sensor switches on, the DSD generates a Lift not ready status
code (14).
WARNING
The Early Ready Delay you determine is only suitable for the
configuration you are using to adjust the value.
Whenever you change any of the following, you must readjust the
Early Ready Delay:
Vibrator;
Lift mode: Full Up or Half Up;
If you are using a TracsTDMA or Raveon radio (see Time Slot
allocation in VE464 Users Manual):
- Number of fleets;
- Number of DSDs;
- TracsTDMA or Raveon Baud Rate;
- Differential GPS;
- Tracking (if TracsTDMA).
Sweep
Pushing
Down
button
Pad is
down
Pressure
sensor
On
Ready
to
DPG
T
0

data
Early Ready
Delay
VE464
Functions > Local Acquisition
552 428XL Users Manual Vol. 1
April 11, 2013
9
Local Acquisition
This function allows you to check the vibrator equipment
separately, as if it were not connected to the recording unit.
For a local acquisition the DPG may operate alone, or the
DPG and DSDs may operate normally but without being controlled by
the recording unit. In that case the Blast command (Firing Order) is
replaced by a manual start (Go pushbutton).
Prerequisites
Unless already done, click the Manual button in the control panel to
isolate the DPG from the recording unit.
You cannot do a local acquisition until the Vibrator Fleet (page 537)
function has been used.
How to use the local acquisition function
1. Click the Local Acquisition function button. A dialog box
appears showing all the DSDs that responded to the Vibrator
Fleet function.
Figure 9-38
2. In the list box, choose (by clicking) the vibrators you wish to use
for the local acquisition. If you do not select any vibrator, then the
DPG will operate alone.
3. In the Basic Type field, enter the type of basic signal you wish to
use. (Basic Types are defined through the Setups menu).
4. Click the option button to choose the execution mode:
- Single: The basic signal is generated once.
VE464
Functions > Set Config
428XL Users Manual Vol. 1 553
April 11, 2013
9
- Continuous: The basic signal repeats endlessly until you click
the Stop button (which appears at the bottom of the dialog box
if you choose this option).
5. Click the Go button. The local acquisition executes. In Single
mode, the local acquisition ends automatically, without any user
action. In Continuous mode, you must click the Stop button to
interrupt the local acquisition, which will actually stop after the
current acquisition is complete.
Set Config
Figure 9-39
This function allows you to remotely enable/disable some configuration
options in the vibrators (DSDs) you select in the list box.
The Use pressure sensor option allows you to enable or disable the
use of a pressure sensor on the vibrators (that is a sensor indicating
whether or not the vibrators pad is down).
You can choose to record the Extended QC data and/or one or more
of the following vibrator motion signals: Mass acceleration (Mass
Acc), Baseplate acceleration (Plate Acc), Force, Reference (Ref).
Use Line filters when storing data: if you choose this option, then
the signals you choose to record on the DSD (using its Local
Archive function) will be filtered with the same Linear Phase or
Minimum Phase filter as selected in the Config window (see Crew
setup window on page 88), just like it were a seismic waveform from
a receiver point along a line. This also applies to the waveform
VE464
Functions > Set Guidance
554 428XL Users Manual Vol. 1
April 11, 2013
9
returned via a DSDs radio to the recording system by the Get
Similarities (page 555) function.
The signals and QC data will be recorded on the disk you choose with
the Medium option button. This can be the disk of a computer attached
to the DSD (in that case, choose NFS from the option button) or a USB
stick plugged onto the DSD itself (choose USB).
Click Go to upload your option settings to the selected DSDs.
Set Guidance
If vibrator Guidance is enabled, the Set Guidance function must be
used to transmit fleet patterns as well as Datum and projection
parameters to DSDs. Beforehand, you must use The Pattern setup
window (page 532) to create a pattern setup. Also, you must use The
Datum Type setup (page 408) and The Projection Type setup (page 411) to
select the appropriate Datum and projection, and click Apply, in the
Positioning window.
Figure 9-40
Click Go to upload the data to the selected DSDs.
Vibrator1
Vibrator2
Vibrator3
Vibrator4
VE464
Functions > Get Similarities
428XL Users Manual Vol. 1 555
April 11, 2013
9
Get Similarities
Figure 9-41
Radio Similarity tests consist of using the VE464 radio link to feed back
a vibrator motion signal from a DSD to the seismic recorder so that it
can be recorded to an SEGD file together with a reference (Pilot) signal
generated by the DPG. Then you can use the SGA tool to correlate the
two signals from the SEGD file and display the correlation wavelet.
The Radio Similarity function opens a window that lets you
Choose the signal (Reference, Force, Mass or Plate acceleration,
Filtered Force) to be radioed from a DSD to the DPG. (Select it from
the Signal option button).
Specify which DSD should return the signal. (Enter its number into
the DSD Nb field).
Choose the DPG reference signal (Return Pilot) to record together
with the signal returned. (Enter the identification number of a
Numeric Pilot defined in The Basic Type setup).
Clicking Go causes the DPG to retrieve the signal from the DSD. This
may take some time, depending on the type of radio used, the number
of DSDs, radio settings, etc. The function is not complete until the Go
button is undimmed. Table 9-2 on page 556 gives the approximate time
for transfer between the DSD and the DPG as a function of the Baud rate
and sweep length, with 428XL Sample Rate @ 2 ms and good radio
transmission conditions.
The SEGD file generated is saved to the /var/dump/test/ directory in
the SEGD repository. The file number is determined by the successive
increments from the initial number specified for Test-type files in the
Config windows Swath setup (page 97).
VE464
Functions > Get Similarities
556 428XL Users Manual Vol. 1
April 11, 2013
9
The resulting file is a special SEGD Test-type file in which the General
Constant field in General Header block 1 is set to 8 (standing for
VE464, instead of 5 for 428XL) and the Trace Header information
must be interpreted as follows:
The type of signal is recorded in the Receiver Point Number field (see
Figure 9-42 below).
The pilot signal (Return Pilot) is recorded as Trace number 1.
The vibrator motion signal returned by the DSD is recorded as Trace
number 2.
The value (0x20) in the Unit Type field indicates this is a VE464
signal.
Figure 9-42 Radio Similarities file Trace Header
For details, see the SEGD file format in 428XL Users Manual Vol. 2.
Table 9-2 Retrieval time versus Baud Rate @ SR =2 ms
Baud rate
Approximate retrieval time (seconds)
SL = Sweep Length SL = 10 s
12000 10 +(3 SL) 40
9600 16 +(4.1 SL) 57
8000 19 +(4.4 SL) 63
7200 23 +(4.6 SL) 69
6000 30 +(5.6 SL) 86
4800 34 +( 7.2 SL) 106
- - - - uni t - - - - - - - - assembl y- - - - . . .
t r ace expt nb l i nb pt nb t yp s/ n ch t ype s/ n . . .
1 1 0 1 ve464 0 1 N/ A N/ A . . .
2 2 0 3 ve464 0 1 N/ A N/ A . . .
SEGD Trace Header (extract)
1 =Return Pilot.
2 =Vibrator Reference.
3 =Vibrator Force.
4 =Vibrator Mass Acceleration.
5 =Vibrator Plate Acceleration.
6 =Vibrator Filtered Force
VE464
Functions > Update Version
428XL Users Manual Vol. 1 557
April 11, 2013
9
Update Version
This function allows you to load a new software version to the DPG.
Prior to using this function, you must install the new version or patch on
the 428XL server with the patcher.sh command (see Server software
patches on page 150 in the Installation Manual). As a result, the files
required for updating the DPG are available from this directory on the
server computer:
/export/home/ve464/delivery
Select the Update.conf file in that directory, using the Browse button,
and then click Go.
Figure 9-43
Wait until updating is complete and then select Reconnect (turn the
VE464 and LCI off then back on).
VE464
Normal acquisition > General
558 428XL Users Manual Vol. 1
April 11, 2013
9
Normal acquisition
In this section:
General (page 558)
Graphic view (page 559)
Numeric view (page 562)
DPG/DSD status codes (page 564)
General
You cannot launch a normal acquisition until the Vibrator Fleet
(page 537) function has been used (each DSD to be used should appear
with a green indicator in the main window's status bar).
When you are ready for a normal acquisition, click the Auto button, in
the main window's control panel. As a result the DPG is waiting for the
Firing Order from the 428XL.
The 428XL will not generate the F O until it receives a Ready status
from the DPG window. When the Ready signal is received from the
vibrator fleet leader, that is when all the desired vibrators are in place
with pads down, it may be retained in the DPG window or automatically
relayed to the recording system, depending on whether the fleets button
in the status bar is released or depressed.
When it receives the F O the DPG generates the Time Break to the
selected DSDs. Then the programmed sweeps are taken and all DSDs
in turn transmit their latest status reports, corresponding to one or more
completed sweeps, to the DPG.
The Status and QC data generated by the DPG are relayed to the GUI
via the Ethernet link and stored into a daily file automatically generated
in the Log window and named normalAcqResult.hci428_0.ddd
where ddd stands for the julian day when the file was created. (They can
be viewed in the Log main window).
QC and status results are not only saved but also displayed in the VE464
main window which makes it easy to appreciate the quality of a vibrator
VE464
Normal acquisition > Graphic view
428XL Users Manual Vol. 1 559
April 11, 2013
9
in real time or through statistical post-processing. The results can be
presented in numeric or graphic form.
The colour of the QC data depends on the alert thresholds you set using
the DSD limits command in the Setup menu.
The radio link allows the DPG to see if any DSD failed to sweep for any
T0. In that case the DPG will report a 98 status (no T0 received).
If the Extended QC option is enabled (see The Sweep Management setup
on page 530), the QC data can be plotted in real time in the results pane
by clicking the Get QC function button. To revert to the normal view,
click the Vibrator Fleet function button.
A button available from the view toolbar allows you to to reset the status
in Normal Acquisition views.
Figure 9-44
Graphic view
The VP and Acq fields respectively display the Vibrator Point number
and Acquisition number the results relate to.
Six bar charts are shown, for the following QC data available in the
status messages from the DSDs: Average Phase, Peak Phase, Average
Distortion, Peak Distortion, Average Ground Force, Peak Ground
Force.
A red horizontal line in each chart shows the limit specified in the Setup
menu (QC Limitcommand).
VE464
Normal acquisition > Graphic view
560 428XL Users Manual Vol. 1
April 11, 2013
9
Figure 9-45
For each DSD used, each chart shows:
A green or orange bar showing the QC value for the latest acquisition
completed (identified in the Acq field):
- Green if the QC value is below the limit,
- Orange if it exceeds the limit or an error is reported:
OV for an overload,
W for a warning,
T for a timing error.
F for a file error.
Average values over
the latest 50 sweeps
QC value during this
sweep
VE464
Normal acquisition > Graphic view
428XL Users Manual Vol. 1 561
April 11, 2013
9
- If the status code from any DSD is incorrect it is displayed in
place of the corresponding QC value.
A blue or red bar showing the average QC value over the latest 50
acquisitions:
- Blue if the average QC value is below the limit,
- Red if it exceeds the limit.
- If the status code from any DSD is incorrect it is displayed in
place of the corresponding QC value.
For the interpretation of Status codes, see page 564.
VE464
Normal acquisition > Numeric view
562 428XL Users Manual Vol. 1
April 11, 2013
9
Numeric view
A table is displayed, derived from the QC reports of the latest 50
acquisitions. It shows the status of the DPG (allowing you to see at a
glance if the PPS signal from the GPS receiver is continually available).
Also, for each DSD, the table shows:
the Vibrator Point number and the Acquisition number,
the Average/Peak Phase, or Distortion or Ground Force, or the Status
Code, whichever you choose from the QC option button.
Figure 9-46
VE464
Normal acquisition > Numeric view
428XL Users Manual Vol. 1 563
April 11, 2013
9
The colour of each cell in the table should be interpreted as follows:
If you choose the Status Code view:
- White background, black writing: QC values are within the
limits.
- White background, orange writing:
- status code 1 or 12 appears, QC values are within the limits but
an Overload and/or Warning has been reported.
- or status code 19 appears.
- White background, nothing displayed: no response from the
DSD.
- Orange background, black writing:
Status codes 1 or 12, or 19 appears, one of the QC values exceeds
the limits, no Overload, and no Warning.
- Orange background, white writing:
Status codes 1 or 12, or 19 appears; one of the QC values exceeds
the limits and an Overload and/or Warning is reported.
- Red background, white writing: if any other status appears.
If you select any of theQC views, the colours should be interpreted in
the same way, but only the selected QC is tested for compliance with
the limit.
For the interpretation of Status codes, see page 564.
Double-clicking in any cell opens a secondary window showing the
detailed QC values contained in the status report from the
corresponding DSD for the corresponding acquisition (see Figure 9-46
on page 562).The following codes may be reported for overloads:
F Raw ground Force reaches hold-down weight.
P Computed Pressure reaches maximum hydraulic pressure.
M Mass position exceeds usable stroke.
V Valve spool position exceeds usable stroke.
VE464
Normal acquisition > DPG/DSD status codes
564 428XL Users Manual Vol. 1
April 11, 2013
9
E Torque motor current, computed, exceeds maximum allowed
current.
The DSD status reports are logged into the database. They can be
viewed in the Log main window and saved to a file.
DPG/DSD status codes
Status generated by DPG
Status code indicative of
successful sweep
Meaning
1 OK
19 OK, Small PPS discrepancy.
Status code indicative of
error
Meaning
20 Hiline error.
21 Wrong sweep definition.
22 Custom definition error.
25 Overrun error.
27 PPS discrepancy.
VE464
Normal acquisition > DPG/DSD status codes
428XL Users Manual Vol. 1 565
April 11, 2013
9
Status generated by DSD
Status code indicative of
successful sweep
Meaning
1 OK, Raw mode.
12 OK, Filtered mode.
19 OK, small PPS discrepancy.
Status code indicative of
error
Meaning
2 Sweep aborted by DSD.
10 Sweep aborted by user.
11 Ethernet error between DSD and PC.
13 Discrepancy in DSD and DPG acquisition table.
14 Lift error.
20 Hiline error.
21 Wrong sweep definition.
22 Custom definition error.
23 Sweep start time expired.
25 Overrun error.
26 Slave recording unit failed to start (on a slave DSD only).
27 PPS discrepancy.
28 Force level too low.
29 DSD didn't have time to save the previous signal to file.
98 No T
0
data received.
99 No T
0
data received or no status report.
VE464
Statistics views >
566 428XL Users Manual Vol. 1
April 11, 2013
9
Statistics views
Whether for statistics on DSDs or on a fleet, the following distinct
views are available: average phase, peak phase, average distortion, peak
distortion, average ground force, peak ground force, Status Codes.
The system calculates the statistical data from the results collected since
it last went to Auto (meaning that your statistics views are lost each
time you go to Auto).
You can choose to view statistical data for each fleet or for each DSD.
Figure 9-47
Figure 9-48
VE464
Statistics views >
428XL Users Manual Vol. 1 567
April 11, 2013
9
In graphic Statistics views, the results are displayed in the form of a bar
chart for each vibrator (or for each fleet) plus a Vx (or Fleet X) bar chart
in the upper-left corner, showing the mean QC value computed on all
the DSDs (or all fleets).
Unless you choose the Manual range option, the horizontal scale is
automatically adjusted so that all samples can be shown. If you choose
Manual range, then the associated fields prompt the outermost values
of the horizontal scale, so that you can change them and adjust the scale
manually.
On each chart the horizontal axis is the scale (divided into a number of
bins) for the QC values (phase or distortion or force), and the vertical
axis is for the number of values in each bin. The following values are
also shown:
number of sweeps (n)
mean value (mean).
standard deviation (SDev), only in the zoom view.
See Bar charts (page 37).
VE464
Statistics views >
568 428XL Users Manual Vol. 1
April 11, 2013
9
428XL Users Manual Vol. 1 569
April 11, 2013
Chapter
10 Log
This chapter includes the following sections:
The main window (page 570)
Editing/saving/loading 428XL parameters (page 576)
SPS files (page 581)
The Shooting setup (page 578)
Operator reports (page 587)
Event log on page 591
Log
The main window >
570 428XL Users Manual Vol. 1
April 11, 2013
10
The main window
To open the jLog main window, click on this icon in the launcher
bar.
Figure 10-1
The Log window performs two important but somewhat unrelated
tasks. One is to provide facilities for handling input and output of text-
based (i.e. non-seismic) data, for example observers' logs, processing
support files, and vibrator QC results. This is often referred to as
binning in & out.
The other is to provide a means of setting up the format for printed
copies of the observer's report.
For each shot or VP acquired, the 428XL stores around 100 parameters
in what is termed the Raw Observer's Log. These include the date,
time and record number but also a multitude of internal and system-
generated figures.
Where available, source position and quality control measurements are
also logged on a daily basis. Receiver array quality control
measurements form a third category of data, stored in a separate file.
Double-click to
expand/collapse
Double-click
(or right-click and
select open)
Navigation pane
View pane
Log
The main window >
428XL Users Manual Vol. 1 571
April 11, 2013
10
Some of these parameters are critical, others are of less significance, but
any or all can be selected for output in one form or another. The Log
window therefore provides several predetermined file formats and also
the means of defining customised file-types where necessary. The most
common output file format is of course SPS.
SPS files can also be used to pre-program the 428XL via the Log
window. The SPS-R, -S and -X files are each loaded in turn, and
together with a few additional parameters entered by the observer,
provide a rapid means of setting up the system for production.
The toolbar
Figure 10-2
View panes
For details on how you can arrange the views and toolbars as you would
like them, see the Hands-on guide (page 52). Each view behaves like a
simple text editor where the keyboard and usual key combinations for
Cut, Copy and Paste shortcuts are allowed. For example, you may want
to paste table cells from another window into a new view and use the
File menu to save the content. If you want to find any particular
parameter or value in a view pane, simply type it into the Search field
and click the Search button .
Saves content of
selected view to
named file
Loads saved
file to new
view pane
Closes all
views
Shooting
parameters
Used to type in
text to find in
selected view
Starts
search
Activates parameters
contained in selected
view
Opens a
blank view
Swath to which to
apply parameters
Log
The main window >
572 428XL Users Manual Vol. 1
April 11, 2013
10
The navigation pane
The navigation (left-hand) pane behaves like a file browser box. To
open any folder, double-click on it (or right-click on it and select
Open from the menu that pops up). The content is viewed in the right-
hand pane.
The navigation pane provides an image of the systems database. It is
important to realize what is meant by the term database in this
context. It is easy to imagine that all of the system data is somehow
assembled into a single giant list, but this is not quite the case. Stored
under the general banner of database are the following:
All system and survey parameters defined in Setup menus.
Pre-acquisition position information including source and receiver
coordinates, assuming that these have been supplied.
All post-acquisition results, for instance Observer's logs, actual
source positions and receiver / source attributes and statistics.
Each set of data is stored in a separate file, but it is not necessary for the
user to know the file or directory name, since the system automatically
keeps track of this itself. Loading a particular data set into the main
window and then choosing Apply instructs the system to locate the
appropriate file and copy the new data to it. Similarly, the navigation
pane gives a straightforward way of extracting a particular set of
information, so that you can export it to whatever you want.
Figure 10-3
Log
The main window >
428XL Users Manual Vol. 1 573
April 11, 2013
10
Depending on what you want to do with your result log files, you can
choose either Display or Save from the right-click popup menu:
Display will open the file in a view page to the right. Then you can
apply filters, i. e. remove any fields (columns) you do not want to
export, and save the file to a disk by choosing Save from the File
menu.
Choosing Save from the right-click popup menu is a quicker way to
save a result log file because this does not open it. Note that filters are
still applied, meaning that if any columns were removed when that
type of file was previously opened, these columns are also discarded
as you save a file this way.
If you have huge log files, choosing Publish all reports and then
downloading from The Web server (page 573) is still a quicker way of
saving them.
The files uploaded or downloaded via the Web server appear in the
Publication folder, with a subfolder (In) containing uploaded files and
another one (Out) containing the files available for downloading.
You can open any setup or SPS file available from the Web server by
simply expanding the Publication folder, right-clicking on the In
subfolder and choosing Open from the popup menu.
You can place setup parameters on the Web server for users to
download, by simply right-clicking on the Parameters folder and
choosing Publish from the popup menu. Likewise, you can place
reports on the Web server by expanding the Logs folder, right-
clicking on the desired subfolder and choosing Publish all reports
from the popup menu.
The Web server
The Web server provides a quick way of exporting result log files. If
files take too long to open and save in the Log window (because you
have a huge amount of data), choose Publish all reports from the
popup menu, instead of opening them in the Log window, and then use
the Web server as follows:
Log
The main window >
574 428XL Users Manual Vol. 1
April 11, 2013
10
1. Open the Web server page.
Figure 10-4 Web server home page
2. Choose User Download.
3. In the authentication box that shows up, enter the same User
Name and Password as you used to open your user session.
4. If you want to save any log file (e. g. an SPS file) to a disk, right-
click on the link to that file in the Web page and then choose Save
Link As from the popup menu.
Figure 10-5 Saving a log file via the Web server
5. Enter a file name and choose a folder in the dialog box that shows
up, and then click Save.
Note that you can also display the file in the Web page, by left-clicking
(rather than right-clicking) on the link. Then you can save it by right-
clicking in the page and choosing Save Page As from the popup menu.
Website
Log
The main window >
428XL Users Manual Vol. 1 575
April 11, 2013
10
Figure 10-6 File opened in Web page
Log
Editing/saving/loading 428XL parameters >
576 428XL Users Manual Vol. 1
April 11, 2013
10
Editing/saving/loading 428XL parameters
The Log window allows you to edit all or part of your system and survey
parameters at any moment and save them to a named file so that you can
load them back at a later date, for example if you want to reuse the same
settings or not much different ones.
You can choose to open the Parameters folder (to view the whole set
of setup parameters), or any of its subfolders (to view only the
parameters of a particular client window).
Figure 10-7
Opening any folder adds a view pane to the right that allows you to edit
its content. For example you may wish to enter the precise coordinates
of the recording truck in order to place it at the exact location in the
Positioning window (see Figure 10-7).
If you want to find any particular parameter or value, simply type it into
the Search field and click the Search button.
To apply your parameter settings to the system, click in the view pane
and select Apply from the Setup menu (or use this toolbar button ).
Search
field
Search
button
Log
Editing/saving/loading 428XL parameters >
428XL Users Manual Vol. 1 577
April 11, 2013
10
Saving
After you open any folder, you can save its content by clicking
in its view pane, then selecting Save from the File menu (or
from the toolbar). In the dialog box that shows up, enter a name
for the file (in the File Name field), choose a directory where to save
it (from the Save In option button), and click Save.
Loading
To load back a parameter file previously saved, select Load
from the File menu (or from the toolbar). In the file browser
box that shows up, choose the desired file and click Open. This
adds a view pane in the main window (the file name appears in the tab
of that view pane). At this stage, the parameters are only viewed. To
load them to the system, click in the view pane and select Apply from
the Setup menu (or use this toolbar button ). You cannot do that
unless you turn off the lines in the Line window (Field Off).
Log
The Shooting setup >
578 428XL Users Manual Vol. 1
April 11, 2013
10
The Shooting setup
Selecting Shooting Setup from the Setup menu opens a dialog box
that allows you to enter parameters which cannot be derived from an
SPS Relation file (when you generate parameter scripts from an SPS
Relation file). These are the type of gain, the Process Type and the shot
identification number for the first shot in the operation table.
Figure 10-8
This window must be set up prior to any attempt to load SPS IN files.
(Click Apply to save and enable your changes).
The Shooting parameters will be used in generating an absolute spread
(for the Line window) and an operation table (for the Operation
window) from a Relation SPS file viewed in the Log window.
Gain Type Nb
You can program gain characteristics that vary as a function of the
distance from the shot point, by defining different zones within circles
around the shot point. Each zone is allocated a channel type.
Default: This field is used to specify the channel type to be used
outside the widest circle.
Log
The Shooting setup >
428XL Users Manual Vol. 1 579
April 11, 2013
10
Radius: The Radius and Gain Type fields are used jointly, to
define circular areas around the shot point and associate a Gain Type
(i. e. a preamp gain) to all receiver channels located within the
specified distance from the shot point.
Gain Type
Enter the desired distance (1 to 9999 m) in the Radius field and the
desired associated Gain Type (1 or 2), and use Add, Change, Delete as
required to generate a list of different channel type areas.
Note If the Radius / Gain type table is empty, the default channel type
will be used across the entire spread.
Shot Id.
Used to identify the first shot point in the Operation main window's
operation table. You can use one of the option buttons to choose either
the number contained in the Record Number field or that in the Tape
Number field of the SPS Relation file, or type the desired number in
the text box.
Process Type
Used to specify the Process Type (1 to 16) to use in the operation table.
Process types are defined using the Operation main windows Setup
menu.
If you do not enter any value in this window, then the system will
default to the following settings:
Gain Type: will automatically default to 1;
Shot Id.: the Record Number contained in the Relation file will
automatically be used as first shot number;
Gain Code Input scale FDU DSU3-428 & DSU1-428
g1 1600 mv 0 dB 5 m/s
g2 400 mV 12 dB
Log
The Shooting setup >
580 428XL Users Manual Vol. 1
April 11, 2013
10
Process Type: will automatically default to 1, except for those shot
points for which a Point Code is specified in the Source SPS file.
Because it is desirable to be able to specify the process type to be used
for each shot, even though no provision is made for this parameter in
the SPS format, Sercel has adopted the following convention: if zero
is entered here as the Process Type, then the value found in the
Point Code column in the SPS Source file will be used as the actual
process type to use.
For this reason, it is recommended that when SPS files are loaded, the
sequence: Receiver, Source and Relation (alphabetical order - R, S,
X) be adopted.
Swath Type
Select the swath your settings are intended for. The drop-down menu
prompts all the swath names you have created and set to Active in the
Config windows Swath setup (page 97).
Log
SPS files > The SPS format
428XL Users Manual Vol. 1 581
April 11, 2013
10
SPS files
In this section
The SPS format (page 581)
Importing an SPS file (page 583)
Exporting an SPS file (page 585)
The SPS format
The SPS format defines four types of files used to input or output some
of the setup parameters of a seismic data acquisition system:
Source file (also called SPS S-file) including source positions,
Receiver file (also called SPS R-file) including receiver positions,
Relation file (also called SPS X-file) used to relate the S-file and R-
file,
Text file (also called SPS T-file) including textual information.
Both the initial (Rev. 0) SPS standard and SPS Rev. 2.1 are supported.
For a description of the SPS standard, see 428XL Users Manual Vol. 2.
Input files
For the system to be able to interpret a Rev. 2.1 file, the H00 header in
the input file must contain this character string: SPS 2.1;
Figure 10-9
Output files
The system generates SPS files in accordance with the Revision option
you select in the Crew setup window (page 88).
H00 SPS f or mat ver si on num. SPS 2. 1;
Column 33
Log
SPS files > The SPS format
582 428XL Users Manual Vol. 1
April 11, 2013
10
If you choose the SEGD Rev 1.0 standard, then the system will
generate SPS files compliant with the initial (Rev. 0) SPS standard;
If you choose the SEGD Rev 2.1 standard, then the system will
generate SPS files compliant with the SPS Rev 2.1 standard.
Initial (Rev 0) SPS standard
Note the following restrictions as compared with the initial SPS
standard: numerals are required in the Line Name, Point Code and Field
Tape Number fields.
SPS Rev. 2.1
The major changes in SPS Rev. 2.1 are the following:
Relation record specification updated to accommodate a larger
number of traces (over 10000);
Geodetic datum updated to reflect WGS84 (rather than WGS72).
Reference to UKOOA P1/90 (rather than UKOOA P1/84).
If you are loading SPS Rev. 2.1 files with Receiver Positions that have
a decimal part, then the decimal part is discarded. For example,
assuming you import an SPS-R file with Line Name and Point Number
fields that look like R 1136.50 2092.50 ... then such a Receiver
Position will be interpreted as Line1136andPoint Number 2092.
Log
SPS files > Importing an SPS file
428XL Users Manual Vol. 1 583
April 11, 2013
10
Importing an SPS file
IMPORTANT
Always import the SPS files in this order: Receiver, Source, Relation.
Select Load from the File menu (or from the toolbar ).
1. In the file browser box, go to the folder containing the SPS files to
import and then select the file or files to import. If you want to
load the whole SPS data, you can select the three files, using the
usual multiple selection method, and load them in one click. To
load SPS Rev. 2.1 files, see also Input files (page 581).
2. Click on Open. This opens an editor view for each file, containing
the imported data and allowing you to make any changes needed.
Note that on a Windows computer, you can drag and drop the
files from the Explorer window to the SPS editor panel instead of
using the File menu.
Figure 10-10
(2) Click to open in
editor view
(1) Sselect
(4) Select swath
(3) Click to select
(5) Click to apply
Alternative method: you
can drag and drop the
files from Windows
Explorer to the SPS
editor panel
Log
SPS files > Importing an SPS file
584 428XL Users Manual Vol. 1
April 11, 2013
10
3. If several views are open, select the one you want to load (click on
its tab). Select the swath the data is intended for. The drop-down
menu prompts all the swath names you have created and set to
Active in the Config windows Swath setup (page 97). Note that
you have to set the swath number manually because it is not
supplied in SPS files.
Figure 10-11
4. Choose Apply from the Setup menu (or use this toolbar button
). You cannot do that unless you turn off the lines in the Line
window or in the Positioning window (Field Off). Also,
remember you must set The Shooting setup (page 578) parameters
prior to applying the content of any SPS file to a swath.
5. Repeat steps 3 to 5 for each file to load and each swath to shoot.
Depending on the type of file in the selected view, clicking Apply will
have different effects:
With a Receiver-type (SPS-R) file, clicking Apply initializes the
planned Receiver positions in the Positioning main window.
With a Source-type (SPS-S) file, clicking Apply initializes the
planned Source positions in the Positioning main window.
With a Relation-type (SPS-X) file, clicking Apply builds an Absolute
Spread in the Line main window and sets up the operation table in the
Operation main windows Source Point setup (page 275).
Remember the parameters specified with the The Shooting setup
(page 578) are also used in generating the operation table.
Swath Number 1
Log
SPS files > Exporting an SPS file
428XL Users Manual Vol. 1 585
April 11, 2013
10
Exporting an SPS file
In the navigation pane, open the Results folder and Logs subfolder.
Open the desired swath folder and then do the following:
1. Right-click on the log file you want to export. Choose Display
and then choose the appropriate SPS output format (S, R or X)
from the menu that pops up, depending on which type of SPS file
you want to create (Source, Receiver, or Relation). This opens an
editor view containing the resulting file and allowing you to make
any changes needed.
Figure 10-12
2. If several views are open, select the one you want to save (click on
its tab).
3. Select Save from the File menu (or from the toolbar ). In the
dialog box that shows up, enter a name for the file (in the File
Name field), choose a directory where to save it (from the Save
In option button), and click Save.
Choosing Save from the right-click popup menu is a quicker way to
save an SPS file because this does not open it. Note that filters are still
applied, meaning that if any columns were removed when that type of
(1) Right-
click to
display
or save
(2) Click to select
view
(3) Click to save
Log
SPS files > Exporting an SPS file
586 428XL Users Manual Vol. 1
April 11, 2013
10
file was previously opened, these columns are also discarded as you
save the file this way.
DSUGPS receiver point positions are recorded in SPS files available
from the Others folder.
Figure 10-13 DSUGPS receiver point positions
If files take too long to open in the Log window (because you have a
huge amount of data), choose Publish all reports from the popup
menu, instead of opening them. Then use the User Download menu
from The Web server (page 573).
Log
Operator reports > Observer Logs
428XL Users Manual Vol. 1 587
April 11, 2013
10
Operator reports
In this section:
Observer Logs (page 587)
APS (page 589)
APS Verbose (page 589)
Source COG (page 589)
Receiver position history data (page 590)
Observer Logs
In the navigation pane, open the Results folder and Logs subfolder.
Open the desired swath folder and then do the following:
1. Right-click on the log file you want to export. Choose Display
and then Observer Log from the menu that pops up. This opens
an editor view containing the resulting file.
2. You can choose which fields to include in the report by clicking
on any column heading and selecting Customize from the menu
that pops up. For details, see Customizing tables (page 58). After
customizing the format of a report, clicking on Save will let you
save your options to a named file that you can reuse as a template
at a later date (by choosing it from the Select a Preset option
button and clicking Apply). To save you changes, click OK.
3. If several views are open, select the one you want to save (click on
its tab).
Log
Operator reports > Observer Logs
588 428XL Users Manual Vol. 1
April 11, 2013
10
Figure 10-14
4. Then you can print it out (e. g. using the File menu). If you want
to export it to another program, select Save from the File menu (or
from the toolbar ). In the dialog box that shows up, enter a
name for the file (in the File Name field), choose a directory
where to save it (from the Save In option button), and click
Save.
Choosing Save from the right-click popup menu is a quicker way to
save an observer report because this does not open it. Note that filters
are still applied, meaning that if any columns were removed when that
type of file was previously opened, these columns are also discarded as
you save the file this way.
See also The Web server (page 573).
(1) Right-
click to
display
or save
(2) Right-click to
customize
Log
Operator reports > APS
428XL Users Manual Vol. 1 589
April 11, 2013
10
APS
(VE432 or VE464 users only).
Vibrator QC and co-ordinate information can be exported in the form of
SPS-like files to an external computer for the purpose of QC analysis or
to the Positioning main window for geographical display.
The APS option extracts the status figures returned for every sweep by
each vibrator. Any field with invalid data is left blank. Unless the
coordinates supplied by the radiopositioning receiver to the DPG are
already in a projection format, the vibrator coordinates are converted
using the projection selected in the Positioning window. Check to see if
the appropriate projection is selected.
(See the format in 428XL Users Manual Volume 2).
See also The Web server (page 573).
APS Verbose
(VE432 or VE464 users only). As the name suggests, the verbose
version gives additional information (See the format in 428XL Users
Manual Volume 2).
See also The Web server (page 573).
Source COG
The following information on the Centre Of Gravity of the source is
logged into a daily file identified by its julian day:
Identification (Line Number, Point Number, Point index from the
input SPS Source file) of the planned shot points,
Position and QC status of the computed COG,
Deviation between planned source positions and actual source COG
positions.
The file can be exported in SPS-like format (see 428XL Users Manual
Vol. 2 for the detailed format).
Log
Operator reports > Receiver position history data
590 428XL Users Manual Vol. 1
April 11, 2013
10
See also The Web server (page 573).
Receiver position history data
The following information, collected and saved to a history file during
operation, can be viewed and exported:
Type of field unit identified,
Date and time when it was last seen,
Receiver position occupied when it was last seen,
Geographical position (if supplied) occupied when it was last seen.
(See 428XL Users Manual Vol. 2 for the detailed format).
See also The Web server (page 573).
Log
Event log >
428XL Users Manual Vol. 1 591
April 11, 2013
10
Event log
An event log in which all operator actions are recorded is available. This
provides the user with an objective record of the successive actions over
a production day.
Expand the Events Viewer folder, and then choose Open from the
right-click popup menu. This allows you to open different log views,
showing different types of events, depending on which subfolder you
right-click on (Production, Tests, etc.).
Figure 10-15
Log
Event log >
592 428XL Users Manual Vol. 1
April 11, 2013
10
428XL Users Manual Vol. 1 593
April 11, 2013
Chapter
11 Plotter
This chapter includes the following sections:
The main window (page 594)
The Banner setup (page 597)
Selecting the traces to plot (page 603)
Plot parameters for production shots (page 606)
Test records (page 613)
Plotter
The main window >
594 428XL Users Manual Vol. 1
April 11, 2013
11
The main window
The jPlotter client window is dedicated to parameters that define what
is displayed on monitor records and how it appears.
Figure 11-1
PLOTTER software is dedicated to processing the geophysical data
(scaling, filtering, AGC) for plotters. It supports 12'' and 24'' Plotters
(selection should be made in the Install window).
It performs the conversion to graphic data (rasterisation) in order to
print it out.
Whatever the interpolation, the maximum number of samples of each
trace plotted is 14844.
Note Traces are numbered from bottom to top, Aux traces at the top.
Plotter
The main window >
428XL Users Manual Vol. 1 595
April 11, 2013
11
You can choose to display the complete data (or part of it) for every
shot, or display one and the same trace for all shots.
By navigating in the left-hand pane, you can access different setup
menus that allow you to adjust AGC and plot parameters differently
depending on the type of input data (normal shot, Field tests, Instrument
tests).
The Normal folder contains your plot parameters for production
shots. It allows you to have special settings for shots with no
processing (in the Raw folder) and different settings for shots with
correlated and/or stacked data (in the Vibro Stack folder).
The Field Test folder, as the name suggests, contains your plot
parameters for sensor tests (Noise, Tilt, Distortion, etc.).
Likewise, the Instrument Test folder contains your plot parameters
for instrument tests (Noise, Distortion, Gain&Phase, CMRR,
Crosstalk, etc.).
Once the different parameters are programmed and activated (by
clicking on Apply), the system automatically uses the sets of
parameters matching the input data.
The plotter is not connected until you choose On Line from the menu
that pops up when you right-click on the plotters folder in the left-hand
pane.
Figure 11-2
File menu
Using the Load / Save commands available from the File menu, all of
the current parameters that have been set up for the entire window can
Plotter
The main window >
596 428XL Users Manual Vol. 1
April 11, 2013
11
be saved to or loaded from a named file. This feature can be useful for
storing configurations that have to be used periodically.
Warning: After installing a new software release, do not load any
parameters from files saved with earlier releases.
Plot Again
This button plots the last shot.
Plot Next
This button plots the next shot.
Abort Plot
This button stops the paper feed and cancels the current plot.
Plotter
The Banner setup >
428XL Users Manual Vol. 1 597
April 11, 2013
11
The Banner setup
To open this window, choose Banner from the Setup menu. It allows
you to choose which parameters to import from the seismic record file
and build the banner as you would like it to appear on your plots.
Figure 11-3
In the navigation pane on the left side are a number of folders containing
all the parameters that you can import into a banner. Choosing any of
them, by double-clicking on it (or dragging and dropping it into the
right-hand pane) causes the associated building block to appear in the
right-hand pane.
The right-hand pane is a text editor in which you can:
- Create a new line by pressing the Return key;
- Type any additional text you like;
- Select a text span by clicking before the first character to select,
pressing and holding down the SHIFT key , and then clicking
behind the last character to select (alternatively, you can press
and hold down the mouse left button and drag the mouse over the
text span to select).
- Move or delete text with the usual Cut, Copy & Paste key
combinations (CTRL+X, CTRL+C, CTRL+V).
Building blocks
Plotter
The Banner setup >
598 428XL Users Manual Vol. 1
April 11, 2013
11
The list box shows the list of existing banner formats. To define a new
banner format, enter its number in the Nb field and then click Add. To
make any changes in the list box, click on the desired row. To save your
changes, click Change (or Add, or Delete).
Double-clicking on a banner format in the list box has it appear in the
text editor so that you can make any changes required. To save your
changes, click Change (or Add, or Delete).
To save the current list of banner formats, click Apply. (To revert to the
former list, click Reset instead).
Global parameters
Parameter Description
Sample Rate Sampling interval (ms)
Type Of Filter
Swath Id
Swath Name
Exploitation mode
Date
J ulian day Record day (1 to 366)
Year Record date (year)
Acq. Time
Acq. hour
Acq. minutes
Acq. seconds
e428 Version
Plotter
The Banner setup >
428XL Users Manual Vol. 1 599
April 11, 2013
11
Record parameters
Process parameters
Line parameters
Parameter Description
File nb. File Number
Record Type
Record Length
Trace headers
Errors
Tape nb. Tape number
Parameter Description
Type of process
Auto cor. peak time Autocorrelation peak time
Max of max aux.
Max of max seismic
Max time values
report
Parameter Description
SFL
Lowest Line Number in the Spread; specifies the origin of the
spread (along with SFN).
SFN
Lowest Receiver Position Number in the Spread; specifies the origin
of the spread (along with SFL).
Spread Nb
Type Of Spread
Live seis. traces Active seismic traces
Nb. of Live traces Number of active traces
Dead seis. traces Dead seismic traces
Nb. of dead traces Number of dead traces
Total nb. of traces Total number of traces
Plotter
The Banner setup >
600 428XL Users Manual Vol. 1
April 11, 2013
11
Shot parameters
Nb. of seismic traces Number of seismic traces
Nb. of aux. traces Number of auxiliary traces
Total nb. of samples Total number of seismic samples contained in a block
Blaster Id Blaster Identification Number
Blaster status
Parameter Description
Shot Nb Shot Number
Source Point Line
Source Point Nb Source Point Number
Source Point Index
Acq. length Acquistion length
Sweep length
Pilot length
Refraction delay
Current Stacking
Fold
Stacking Fold
Source Easting
Source Northing
Source Elevation
Type of source
Uphole time
Tb window
User header
Plotter
The Banner setup >
428XL Users Manual Vol. 1 601
April 11, 2013
11
Noise parameters
Plot parameters
Parameter Description
Noise EIim. Type Noise EIimination Type (
Threshold var Threshold option (Hold or Variable)
History editing type
History range
History taper length
History threshold init
value
History zeroing
length
Nb. of windows Number of windows
Low traces percent
Low traces value
Noisy traces percent
Noisy traces value
Low noisy verbose
report
Parameter Description
Plot type
Plot Control Type
High cut
High cut filter
Low cut
Low cut filter
Notch filter
Notch
Aux. gain
Seismic gain
Plotter
The Banner setup >
602 428XL Users Manual Vol. 1
April 11, 2013
11
AGC window length
WZ velocity
Inline spacing
Crossline spacing
Release time
Time exponent
Plotter
Selecting the traces to plot >
428XL Users Manual Vol. 1 603
April 11, 2013
11
Selecting the traces to plot
For each type of record (production shots or tests), you can choose to
plot all traces or only groups of traces you specify, or one and the same
trace. To do that, you simply have to create a table containing the
description of each group of traces you would like to plot, for each type
of record:
1. Click on the desired type of record, e. g. the Raw subfolder (see
Figure 11-4) in the navigation pane to the left;
2. Enter the desired number of groups into the Number of groups
field;
3. Click in the Group field. As a result, the system automatically
creates the appropriate number of rows in the table so that you can
define each eligible group as you like with the parameters
described below.
4. Click on Apply.
Figure 11-4 Selecting the traces to plot
Number of groups
This field is used to tell the system how many groups you want to
describe, so that it can create the necessary number of rows in the table.
Use these fields to determine the recurrence
rate of the selected group or groups.
1. Choose type of
record
2. Specify how many
groups you want to
describe
3. Click to create
the necessary
rows in table
Plotter
Selecting the traces to plot >
604 428XL Users Manual Vol. 1
April 11, 2013
11
Group
As you click in this field, the system automatically creates a row for
each group of traces to describe, depending on what you specify in the
Number of groups field.
A button is associated with each group (row), on the left of it, in the
table. You have to tick that button if you want the group to be plotted
when eligible. Its recurrence rate on the printout depends on what you
specify in the fields at the foot of the table, determining how many
groups will be plotted and how often (every N records).
Figure 11-5
Aux
Tick this button if you want to plot auxiliary traces.
Sensor code
This field lets you to choose either all the traces specified regardless of
the type of sensor, or only traces with the type of sensor you specify.
Channel/Line
Choosing Channel lets you determine the eligible group by specifying
the first trace to plot (Start at field), the number of traces to plot
(Total field) and the step (Incr field) to use in counting the traces.
The same group of traces from all lines will be eligible for plotting.
Choosing Line lets you determine the eligible group by specifying the
first line to plot (Start at field), the number of lines to plot (Total
field) and the step (Incr field) to use in counting the lines. All the
matching traces on the specified lines will be eligible for plotting.
How often
How many
groups
Plotter
Selecting the traces to plot >
428XL Users Manual Vol. 1 605
April 11, 2013
11
Start at
Used to specify the sequential number of either the first trace or the first
line (depending on whether the Channel or Line option is selected)
eligible in the group.
Total
Used to specify either the number of traces from each line or the number
of lines (depending on whether the Channel or Line option is
selected) eligible in the group.
A button is associated with the Total field. If you tick that button, then
system will automatically determine the total number of traces eligible
in the group, depending on what you specify in the other fields. If you
untick the button, then you have to specify how many traces or lines you
want the group to include.
Incr
Used to specify the sequential number increment step for counting in
either the traces or the lines (depending on whether the Channel or
Line option is selected) eligible in the group.
Plotter
Plot parameters for production shots > Processing setup
606 428XL Users Manual Vol. 1
April 11, 2013
11
Plot parameters for production shots
In this section:
Processing setup (page 606)
Rendering setup (page 610)
Format setup (page 610)
Processing setup
Some of the parameters appearing in the Processing pane are specific to
the kind of data to be plotted. Below is a description of all the
parameters prompted after you click on the Normal folder in the
navigation pane.
Figure 11-6
Choose the desired processing from the Control option button, then
set the associated parameters.
AGC
For Normal shots only. With the AGC processing option, the gain of
each trace is automatically adjusted, depending on the level of the
signal.
If you choose this option, the system computes the average sample
value over a time window you have to specify in the associated
Window Length field.
Plotter
Plot parameters for production shots > Processing setup
428XL Users Manual Vol. 1 607
April 11, 2013
11
The average value is used to determine a gain that is applied to the
sample at the centre of the window. The system repeatedly updates the
average value as the time window shifts from the time when AGC starts
being applied to the end of the plot.
Geographic AGC
For Normal shots only. The Geographic AGC processing option lets
the system compute source-to-receivers distances from the geographic
coordinates available (you do not have to supply the Inline spacing
and CrossLine spacing).
Note You have to click on Apply after entering SPS data.
Time exponent
(0.00 to 9.00). For Normal shots only. If you choose this option, the
same gain is applied to all traces. The gain increases as an exponential
function of the time over the whole trace. You simply have to specify
the value of the exponent.
Normalization
For Normal shots only. If you choose this option, then the system will
look for the maximum sample value on each trace to determine the
appropriate gain to be applied to the whole trace.
Window Length
(100 to 5000 ms). For Normal shots only. Time interval over which
the system computes the average value of samples to determine the
AGC gain, if the AGC or Geographic AGC option is used.
Wz Velocity
(Allowable range: 1 to 99999 m/s). For Normal shots only. If you
choose AGC or Geographic AGC as a processing to plot the traces, a
Wz Velocityfield is available that allows you to specify the
propagation velocity of the shot wave. This will enable the system to
Plotter
Plot parameters for production shots > Processing setup
608 428XL Users Manual Vol. 1
April 11, 2013
11
calculate the time when the AGC should be applied to the traces on the
plotter, deducing it from the source-to-receivers distances.
Note By default the source-to-receiver distance is assumed
determined in metres, therefore the velocity in metres/second.
If the distance is determined in any other unit, then the velocity
you enter should be expressed in the corresponding unit instead
of m/s (the unit must be consistent with SPS data).
Inline spacing
(1.0 to 999.0 m). For Normal shots only. Distance between receiver
points (i. e. traces) in each line. Used to determine the time when AGC
should be applied, unless you choose the Geographic AGC option.
CrossLine spacing
(1.0 to 999.0 m). For Normal shots only. Distance between lines.
Used to determine the time when AGC should be applied, unless you
choose the Geographic AGC option.
Scaling
Scaling is used to specify an amplitude gain (dB) for the traces plotted,
to magnify or shrink the traces. Changing the Scaling setting for any
shot will make it more difficult to compare the plot with another shot.
Note Adjust both Scaling and Clipping as required for better
legibility of the plot.
Seismic: (-144 to 144 dB). Sets the amplitude of seismic traces on the
plot.
Auxiliary: (-144 to 144 dB). Sets the amplitude of auxiliary traces on
the plot.
Plotter
Plot parameters for production shots > Processing setup
428XL Users Manual Vol. 1 609
April 11, 2013
11
Filters
For Normal shots only. These three buttons allow you to specify a
Low Cut frequency, a High Cut frequency and a Notch filter frequency
for the traces to plot.
Note The three parameters (Low Cut, High Cut, Notch) are not
applied to Auxiliary traces.
Low Cut: If you wish to set a low-cut filter for the plot, choose Low
Cut and type the desired low-cut frequency (5to 500 Hz) in the
associated field. If you wish to remove the filter, unselect Low Cut.
High Cut: If you wish to set a high-cut filter for the plot, choose High
Cut and type the desired high-cut frequency (30 to 500 Hz) in the
associated field. If you wish to remove the filter, unselect High Cut.
Notch: If you wish to set a notch filter for the plot, choose Notch and
type the desired notch frequency (30.00to 500.00 Hz) in the
associated field. If you wish to remove the filter, unselect Notch.
Note The Low Cut and High Cut buttons allow you to set up different
types of filters:
Figure 11-7

F F F
High cut Low cut High cut
Band pass
Low cut
Plotter
Plot parameters for production shots > Rendering setup
610 428XL Users Manual Vol. 1
April 11, 2013
11
Rendering setup
Figure 11-8
Page setup
Allows you to specify which type of banner to use. This determines the
content of the banner to appear ahead of plots. See The Banner setup
(page 597).
Orientation
This option button allows you to choose the orientation of plots
(Portrait/Landscape).
Format setup
Figure 11-9
Plotter
Plot parameters for production shots > Format setup
428XL Users Manual Vol. 1 611
April 11, 2013
11
Time Sequential
The traces are plotted along the paper.
Trace Sequential
The traces are plotted across the paper width.
Global rendering for Seismic and Aux
This option lets you customize the global aspect of the plotter output by
means of the parameters below.
Mode
You can choose between the following options:
Figure 11-10
Traces/inch
(Auto or 1 to 99) Number of traces to plot per inch. Choosing Auto will
adjust the trace spacing as a function of the number of traces.
Note Disproportionate labels may result if you choose Auto and
Time Sequential with too few traces to plot.
Clipping
(1 to 10 traces) This button is used to specify the number of traces that
any trace is allowed to overlap. Any trace exceeding the specified
overlapping limit is clipped to that limit.
+VA
-VA
Wiggle +VA
Wiggle -VA
Wiggle
Plotter
Plot parameters for production shots > Format setup
612 428XL Users Manual Vol. 1
April 11, 2013
11
Note Adjust both Scaling and Clipping as required for better
legibility of the plot.
Time
Start: (0 to 64000 ms) Time of the first sample to plot.
Length: (Auto or 1 to 64000 ms) If you choose Auto, the system will
automatically set the length of the plot to the maximum or to the best,
depending on the record parameters. Otherwise, specify the desired
length for the plot.
Interpolation: (Auto or 16, 8, 4, 2 1 to 1, or 1 to 2, 4, 8, 16). Number
of dots interpolated by the system for each sample.
If you choose Auto, then the system will automatically set the
interpolation to the best, depending on the record parameters.
Examples: 1 to 4 means that 4 dots are plotted for each sample (this
expands the plot); 4 to 1 means that each dot stands for 4 samples (this
shrinks the plot).
Plotter
Test records >
428XL Users Manual Vol. 1 613
April 11, 2013
11
Test records
If you need specific plot parameters for any type of test, choose the
desired folder in the navigation pane and then set the parameters as you
like. For test records, you have a single processing parameter to set
(Scaling). For other parameters, see Rendering setup (page 610) and
Format setup (page 610).
Sensor tests
Figure 11-11
Instrument tests
Figure 11-12
Plotter
Test records >
614 428XL Users Manual Vol. 1
April 11, 2013
11
428XL Users Manual Vol. 1 615
April 11, 2013
Chapter
12 VE432
This chapter includes the following sections:
The main window (page 616)
The Vibrator Crew setup (page 618)
The Basic Type setup (page 621)
The Acquisition Type setup (page 637)
The Radio Management setup (page 641)
The QC Limit setup (page 644)
The QC Choice setup (page 645)
The T0 Time setup (page 646)
The Pattern setup window (page 648)
Functions (page 652)
Normal acquisition (page 672)
Statistics views (page 679)
VE432
The main window >
616 428XL Users Manual Vol. 1
April 11, 2013
12
The main window
The jVE432 window is only available if you choose the VE432
Vibrator type (page 72) option in the Install window.
To open the VE432 main window, click on this icon in the
launcher bar.
This main window serves as the Graphic User Interface for a VE432
vibrator controller (VE432 DPG). For an introduction to the VE432
system and details on what it is able to do, how it works, how to deploy
it, see the VE432 Installation and Reference manual.
Figure 12-1
The View menu and the associated toolbar allow you to customize the
main window by choosing one or more views to display. Then you can
resize your display panes by dragging the desired border.
You can show or hide columns in tables by right-clicking in any column
heading and selecting Customize (see Figure 2-25).
The Setups menu and the associated toolbar allow you to customize
sweep signals, set parameters for vibrator fleets and adjust QC
parameters.
Setup toolbar
Click to show
view
Click to close view
Function toolbar
VE432
The main window >
428XL Users Manual Vol. 1 617
April 11, 2013
12
The Functions menu and the associated toolbar provide local controls
to be used outside of seismic acquisition periods to adjust the
parameters of vibrator DSDs.
VE432
The Vibrator Crew setup >
618 428XL Users Manual Vol. 1
April 11, 2013
12
The Vibrator Crew setup
Figure 12-2
The Vibrator Crew setup dialog box is used to create a seismic crew by
building the list of vibrators available in that crew, that is the list of
vibrator electronics (DSDs) seen by the recorders GUI, and specifying
how many vibrator fleets will be available.
To save the description of the crew, click Apply. This updates the status
bar under the function buttons in the main window: an indicator appears
for each DSD incorporated in the crew, associated with the
identification number of the vibrator (e. g. V1, V2, etc.). The indicator
is blank until you run the Look and Set DSD or Fleet functions.
Clicking Apply also clears all the vibrators lists in the dialog boxes that
will open when you click some of the function buttons (Set DSD, Get
DSD, etc.)
As a result, you have to run the Look function to update the vibrators
lists.
Clicking Reset instead of Apply reverts to the former settings.
Crew Nb
This field is used to enter the crew identification number (1 to 4).
VE432
The Vibrator Crew setup >
428XL Users Manual Vol. 1 619
April 11, 2013
12
A DPG can address only one crew. The crew identification number is
used to preclude any interference with other crews working nearby.
Fleets
Buttons used to specify the fleets (i. e. sources) to be used in the crew.
For example, activating buttons 1 and 3 will cause two fleets to be
available: fleets 1 and 3.
(To specify the vibrators incorporated in each fleet, see Vibrator Fleet
(page 655).
Type
For each item in the list, this option button allows you to choose the type
of controller: either a DSD or a Slave DPG.
Using a Master/Slave configuration makes it possible to record more
traces without increasing the number of vibrators or to use two
recording systems at two distinct places. The DPG in the Slave
recording truck needs to be configured with DPG-Slave software. As a
result it is seen as a DSD from the Master DPG. The Slave DPG
generates a reference pilot signal synchronous with the Time Break. It
does not control any DSD.
For more details, see The VE432 DPG Installation & Reference
Manual.
Id
This field is used to specify the identification number (1 to 28) of each
vibrator (i. e. DSD) available to the crew. After specifying any vibrator
number in this field, click the Add button to enter it into the list box.
DSD Network
This button is used to specify whether a DSD network is implemented
and enable the Navigation-driven shooting (page 309) mode. The DSD
network allows each DSD in a fleet to communicate with the fleets
leader via an Ethernet wireless datalink. As a result, when all the DSDs
VE432
The Vibrator Crew setup >
620 428XL Users Manual Vol. 1
April 11, 2013
12
in the fleet are ready for the next sweep, the fleet's leader is able to
supply the DPG with a Ready message containing the geographical
position of the Centre Of Gravity of the fleet, referred to as Source
COG. This allows the system to select the Source Point automatically
in the Operation window and display it in the Positioning main window.
VE432
The Basic Type setup > Overview
428XL Users Manual Vol. 1 621
April 11, 2013
12
The Basic Type setup
In this section:
Overview (page 621)
Linear (page 623)
dB/Hz Log, Tn and dB/Octave Log (page 624)
Pulse (page 629)
Random (page 630)
Custom (page 631)
Compound (page 634)
Delay (page 635)
Deboost option (page 635)
Generating a Basic Type setup (page 636)
Overview
To open the Basic Type setup window, select Basic Type from
the Setups menu. Creating a Basic Type is the process of
describing a basic signal to be used:
- by the DSDs to generate sweeps for the vibroseismic source
(vibrator control signal),
- and/or by the DPG to generate up to four Pilots to be used as
reference signals for correlation processors.
You can create up to 32 different Basic Types, which can be combined
using the Compound option.
Below are the allowable ranges for the entry fields that may appear in
the Basic Type setup window.
Start Taper 0 to 32000 ms.
End Taper 0 to 32000 ms.
VE432
The Basic Type setup > Overview
622 428XL Users Manual Vol. 1
April 11, 2013
12
The start and end tapers are used to reduce the side lobes appearing in
the correlation function of the sine wave or pulse. (The ratio of the peak
amplitude to the side lobes is a measure of the quality of the correlation
function).
Initial Phase -180 to +180.
Amplitude 0 to 100%.
Length 1 to 64 s (only for Random, Custom and Delay type
signals).
Ti 2 to 16 values from 0 to 64 s (T1 must be 0).
Tj 2 to 16 values from 0 to 64 s (T1 must be 0).
Ai 2 to 16 values from -40.00 to +40.00 dB.
Aj 2 to 16 values from 0 to 100%.
Fi 2 to 16 values from 1 to 250 Hz in increasing order
of frequency.
Frequency 1 to 250 Hz (only for Pulse type).
Each basic signal type can be composed of up to 16 segments (32 for
the dB/Hz Log and dB/Octave Log basic signals).
For details on each basic signal, see below.
VE432
The Basic Type setup > Linear
428XL Users Manual Vol. 1 623
April 11, 2013
12
Linear
You define a Linear-type signal through an analytic description. At the
signal start and end times, and possibly at particular times in between,
you have to specify:
the signal frequency (Hz),
the signal amplitude (% of requested drive level).
Figure 12-3
The Frequency variation vs. time is linear within each frequency
segment. Frequency segments are defined as follows:
The first Ti,Fi pair (T1,F1) specifies the initial frequency hence:
T1=0 sec., F1 =initial frequency.
The second Ti,Fi pair specifies the end time of the first segment (T2)
and the signal frequency at this time is F2, etc.
You must define at least two Ti,Fi pairs (i.e. one frequency segment).
Amplitude segments are defined as follows:
The first Tj,Aj pair (T1,A1) specifies the initial amplitude, hence:
T1=0 sec., A1 =initial amplitude.
Frequency
lines
Signal
amplitude
VE432
The Basic Type setup > dB/Hz Log, Tn and dB/Octave Log
624 428XL Users Manual Vol. 1
April 11, 2013
12
The second Tj,Aj pair specifies the end time of the first segment (T2)
and the signal amplitude at this time is A2, etc.
Within each amplitude segment, the amplitude variation vs. time is
linear.
The last Tj determines the total signal length. You must define at least
two Tj,Aj pairs (i.e. one amplitude segment).
Ti and Tj may be different both in number and value but the last Ti and
the last Tj must be the same value.
Note See also page 621.
dB/Hz Log, T
n
and dB/Octave Log
Note For non-linear sweeps, the slope in dB is the spectrum slope
before correlation, that is assuming the slope of the power
spectrum is NdB (N being the slope value programmed in the
Basic Type setup), the spectrum of autocorrelation will have a
2 NdB slope.
dB/Hz Log
You define a LOG-type signal through a spectral description, by
specifying;
- the amplitude (dB) of two or more frequency lines in the signal
spectrum,
- the signal amplitude (% of requested drive level) at the start and
end times and possibly at particular times in between.
The Frequency variation vs. time is logarithmic within each
frequency segment. This signal type is used to compensate for the non-
linear response of the ground (HF damping).
VE432
The Basic Type setup > dB/Hz Log, Tn and dB/Octave Log
428XL Users Manual Vol. 1 625
April 11, 2013
12
Figure 12-4
Each Fi,Ai pair defines a spectrum line at frequency Fi with amplitude
Ai. Fi,Ai pairs are listed in the increasing order of frequency. You must
define at least two spectrum lines. You can specify up to 32 frequency
segments.
Amplitude segments are defined as follows:
The first Tj,Aj pair (T1,A1) specifies the initial amplitude, hence:
T1=0 sec., A1 =initial amplitude.
The second Tj,Aj pair specifies the end time of the first segment (T2)
and the signal amplitude at this time is A2, etc.
Within each amplitude segment, the amplitude variation is linear.
You must define at least two Tj,Aj pairs (i.e. one amplitude segment).
The last Tj determines the total signal length. You can specify up to 32
amplitude segments.
Frequency
lines
Signal
amplitude
VE432
The Basic Type setup > dB/Hz Log, Tn and dB/Octave Log
626 428XL Users Manual Vol. 1
April 11, 2013
12
The Frequency is expressed as:
Where:
SegRa =Sb/Se =10
(-Ra/10)

Sb =Slope at the start of the log segment.
Se =Slope at the end of the log segment.
Fb =Start frequency.
Fe =End frequency.
T =Te-Tb =Basic signal length.
Ra represents the attenuation (in dB) within the signal
spectrum.
Example:
Ra=10 - 5 =5
SegRa =0.316
Note Choose the Deboost option if the signal is to be used for
Deboost-type processing. See Deboost option (page 635).
See also page 621.
Delta dB values
Fi (Hz) Ai (dB)
8 5
80 10
|
|
.
|

\
|
+
|
|
.
|

\
|

+ = ) 1
1
( 1 log
1
log
) (
SegRa T
t
SegRa
Fb Fe
Fb t Fi
VE432
The Basic Type setup > dB/Hz Log, Tn and dB/Octave Log
428XL Users Manual Vol. 1 627
April 11, 2013
12
dB/Octave Log
Figure 12-5
The Ti,Fi fields are used to specify the frequency at the start time and
at the end time (two Ti,Fi pairs are required). A single frequency
segment is allowed.
The Tj,Aj fields are used to specify the amplitude (% of requested drive
level) at the start time, at the end time and, if required, at particular
times in between (at least two Tj,Aj pairs are required). The last Tj
determines the total signal length. You can specify up to 32 amplitude
segments.
The Slope dB/Octave field is used to specify the slope in dB/oct of the
signal spectrum (SdB in the expression below).
The Frequency is expressed as:
Frequency
lines
Signal
amplitude
n
SdB
3
---------- 1 + =
Fi t ( ) Fb
n t
T
--- Fe
n
Fb
n
( ) +
1
n
---
=
VE432
The Basic Type setup > dB/Hz Log, Tn and dB/Octave Log
628 428XL Users Manual Vol. 1
April 11, 2013
12
T
n
Same as dB/Hz Log type (with no Deboost option), except for the
frequency variation which is exponential rather than logarithmic.
Figure 12-6
The Frequency is expressed as:
Frequency
lines
Signal
amplitude
( )
n
n n n
Fb Fe
T
t
Fb t Fi
SegRa
Fb
Fe
Fb
Fe
n
(
(

|
|
.
|

\
|
+ =

|
.
|

\
|
|
.
|

\
|
=
1 1 1
) (
log log
log
VE432
The Basic Type setup > Pulse
428XL Users Manual Vol. 1 629
April 11, 2013
12
Pulse
Figure 12-7
Two parameters are needed to define a pulse-type signal:
- a frequency (F) that determines the pulse width (T) as:
T =1/F
- an amplitude (% of requested drive level).
A 1-second signal is generated, with the pulse peak centred at
0.5second.
A Pulse-type signal is needed for two purposes:
Checking the polarity of the devices in the system.
In operation, pulse reflection from shallow layers of the ground.
0
-0.5
-1
0 100 200 300 400 500 600 700 800 900 1000
T
Time (ms)
VE432
The Basic Type setup > Random
630 428XL Users Manual Vol. 1
April 11, 2013
12
Random
Figure 12-8
The Random basic signal type allows you to take sweeps that do not
generate resonant frequencies (e. g. the resonant frequencies of
buildings) and also allows two or more vibration sources to be used
simultaneously with minimum interference. The Random type
generates a Pseudorandom noise signal based on one of the four
different polynomial sequences selectable from the Polynomial
option button:
65spoly1: first polynomial with 65535-ms sequence length
65spoly2: second polynomial with 65535-ms sequence length
8spoly1: first polynomial with 8191-ms sequence length
8spoly2: second polynomial with 8191-ms sequence length
The two 8-second polynomial options should only be used with
listening times less than 8 seconds. The polynomial sequences have
been appropriately designed for minimum cross-correlation residual.
VE432
The Basic Type setup > Custom
428XL Users Manual Vol. 1 631
April 11, 2013
12
You define a Random-type basic signal by specifying:
the polynomial option,
the amplitude (dB) of two or more frequency lines in the spectrum,
the signal length (duration), and start and end tapers.
Frequency segments should be defined as follows:
- The first Fi,Ai pair specifies the initial frequency (F1) and the
initial amplitude (A1). F1 must be 5, 7, 10, 14 or 20 Hz.
- The second Fi,Ai pair specifies the frequency (F2) and the
amplitude (A2) of the signal at the end of the first segment, etc.
You must define at least two Fi,Ai pairs (i.e. one frequency
segment).
Note Choose the Deboost option if the signal is to be used for
Deboost-type processing.
See also Deboost option (page 635).
Custom
Figure 12-9
To define a Custom basic type signal, you just have to specify the
name of a file saved on the vibrator electronics PCMCIA interface,
containing the description of a customized signal of yours.
VE432
The Basic Type setup > Custom
632 428XL Users Manual Vol. 1
April 11, 2013
12
Note The system will not check to see if you entered a consistent file
name until you run the Set DSD function.
Note You don't have to specify the Length (this field will be updated
by reading the specified file when you run the Set DSD
function).
You have to define the shape of the Custom sweep and create a file
containing the samples required by the VE432 (see the example below)
with a tool of your own, save it as an ASCII, DOS- or UNIX-format file,
and then load it to the DPG. See How to load a Custom sweep file to a
DPG (page 633).
The sweep should be defined with 2000 samples per second, one sample
per line. Each sample should be a floating value in ASCII format, scaled
between -1 and +1.
Comments are allowed, beginning with #.
Example
#
# Ser cel Cust omsweep
# f i l e cust om1. asc
# 11. 03. 1999
#
0. 0000001 # st ar t t aper .
0. 0000002
- 0. 0000001
- 0. 0000004
. . .
0. 99567
. . .
0. 0000001 # end t aper
VE432
The Basic Type setup > Custom
428XL Users Manual Vol. 1 633
April 11, 2013
12
The Hilbert transform of the reference can be supplied too, in the form
of a second column of figures, in a Custom sweep file. (The reference
signal is assumed described in the first column). The two columns are
required for VSR if a Time QC is desired (calculation of phase,
distortion, force). See SQC Dump mode with VE432 (page 361).
How to load a Custom sweep file to a DPG
After creating a Custom sweep file you have to move it to the GUI on
the server computer, via whatever medium is available and appropriate
(CD-ROM, etc.). You may put it into the /tmp directory or any directory
beginning with /users/ (e. g. /users/428XL/ve432/). The file name
should be in DOS format, i. e. 8 characters max for the name, 1 dot, 3
characters max for the extension (e. g. custom1.asc).
To load a custom file to a DPG:
1. Select PCMCIA tools from the Functions menu (see Figure 12-
37 on page 669).
2. Choose the Load custom file to PCMCIA option.
3. Use the Browse button to select the file to load.
4. Click Go. The file is transferred to the DPG. The DPG performs
the necessary format conversion and stores the result to the
PCMCIA card without changing the file name.
For example the /users/428XL/ve432/custom1.asc file is saved as
custom1.asc on the PCMCIA card.
Generate a PCMCIA card containing the custom sweep file for each
DSD and each DPG to use.
VE432
The Basic Type setup > Compound
634 428XL Users Manual Vol. 1
April 11, 2013
12
Compound
Figure 12-10
The Compound basic signal type allows you to create a basic sweep
signal composed of a combination of two or more basic types. You just
have to enter the number of each of those basic types needed into the
Basic Type field and click Add in the upper pane. In the lower pane,
enter a new number and label and click Add then Apply.
You can use this option to define a signal including a delay time: create
a delay type with the desired delay length, using the Delay option, then
insert it at the beginning of a Compound sweep (i. e. the delay-type
signal should be the first in the list).
Note The signals will be generated in the order determined in the list
box.
VE432
The Basic Type setup > Delay
428XL Users Manual Vol. 1 635
April 11, 2013
12
Delay
Figure 12-11
The Delay basic signal type uses a single entry field (Length,
allowable range 1 to 64 s).
If you wish to delay any basic signal, specify the desired delay time in
the Length field. In the lower pane, enter a new number and label and
click Add then Apply. Then use the Compound tab to create a new
basic type including that delay. See Compound (page 634).
Deboost option
If you choose the Deboost option for Log or Random type signals, the
428XL will make the necessary computation for the frequency
spectrum shape of the output signals to be the same as that of a linear
sweep.
Figure 12-12
Note Whether or not the Deboost option is enabled, the VE432
generates the same sweep. This option does not affect the
behaviour of the VE432.
VE432
The Basic Type setup > Generating a Basic Type setup
636 428XL Users Manual Vol. 1
April 11, 2013
12
Generating a Basic Type setup
The Basic Type setup window allows you to define up to 32 different
basic signal types.
1. Click on the appropriate tab, depending on which mathematical
function you wish to use.
2. In the upper pane, set the parameters as required.
3. In the lower pane:
- The list box shows the list of basic signals already defined, if
any.
- The Number field is used to enter or display a basic signal type
number. Example: 25 refers to basic signal #25 (bas25 in the
list box).
- The Label field is used to enter or display a more user-friendly
label for the basic signal type. The default label refers to the
mathematical function selected for the basic signal.
- The basic signal #displayed in the Number field and defined
with the selections made in the upper pane is added into the list
box when you click the Add button (unless it is already defined).
If you double-click any basic type in the list box, then its characteristics
appear in the upper pane. To make changes, click it in the list box, make
the desired changes and click Change or Delete. Clicking Apply saves
your changes.
Any changes to the Basic Type currently used will not be effective until
you use the Set DSD function to initialize the DSDs.
VE432
The Acquisition Type setup >
428XL Users Manual Vol. 1 637
April 11, 2013
12
The Acquisition Type setup
Figure 12-13
The list box shows the list of existing acquisition types. An
Acquisition Type tells the DSDs selected in a vibrator fleet what to
do. To define an Acquisition Type you have to specify:
- the Basic signal type to be used by all DSDs in the fleet,
- the signals (up to four) to be supplied by the DPG through its
Analog Pilot outputs, if required (to be used in the correlation
process),
- two options for the DSDs (baseplate automatic lift, and
synchronization with a picked-up power line signal),
- an acquisition number and label.
Note Acquisition Types are used in defining Process Types in the
Operation window.
Acquisition Type & Label
The Acquisition Type field is used to enter an identification number
(1to 32) for the Acquisition Type. You will need that identification
number when you create a Process Type in the Operation window
(see The Process Type setup on page 256).
VE432
The Acquisition Type setup >
638 428XL Users Manual Vol. 1
April 11, 2013
12
The Label field is used to enter a label (up to 16 ASCII characters) for
the Acquisition Type. A default label is prompted by the system (acq
type #) but you can enter a more user-friendly one.
Note A noise elimination Threshold Type (modulo 16) is
automatically associated with each Acquisition Type:
Threshold Type 1 <=> Acq Type 1
Threshold Type 2 <=> Acq Type 2
... ...
Threshold Type 16 <=> Acq Type 16
Threshold Type 1 <=> Acq Type 17
... ...
Threshold Type 16 <=> Acq Type 32
Basic Type Nb
This field is used to specify which Basic (sweep) signal the DSDs
should generate. Enter the desired Basic Type number (defined using
The Basic Type setup on page 621).
Pilot Basic Nb
The DPG can generate up to four Pilots, available on its Analog Pilot
outputs, to be used as reference signals for the correlation processor. A
Pilot signal is synchronous with the Time Break signal and usually very
similar to the fleet's sweep signal. The Pilot signals should be fed to
FDUs used as Auxiliary channels on the acquisition system. (See
Installation Manual).
When you create an Acquisition Type, you specify which Pilots the
DPG should generate. You do that by entering the desired Basic Type
number (defined using The Basic Type setup on page 621) into the
necessary fields (p1 to p4).
VE432
The Acquisition Type setup >
428XL Users Manual Vol. 1 639
April 11, 2013
12
Auto Lift
Select this option if you wish the vibrator baseplate to automatically lift
at the end of the sweep depicted by the acquisition type. The baseplate
will not lift automatically, however, unless and until the Auto Lift
button on the DSD is activated too.
High Line Sync
The High Line Sync option allows you to select a synchronization
signal for the T0 time. Click this button and select the desired option in
the menu that pops up. The three possible options are:
Free: no synchronization
Up: T0 synchronized on the transition from the negative to positive
half period of the High Line signal
Down: T0 synchronized on the transition from the positive to
negative half period of the High Line signal.
Note High Line synchronization is irrelevant for a pseudo-random
signal.
This function is used to remove the noise radiated by nearby power
lines, by means of the following technique:
- High Line noise is intendedly picked up and fed to the DPG (see
VE432 Installation Manual).
- The sweeps are ALTERNATIVELY triggered on the positive-
going and negative-going transitions of high line noise.
- With an even number of sweeps, any high line noise picked up
by the receivers is theoretically removed through the stacking
process.
To define a new acquisition type, enter its number in the Acquisition
Type field, select the desired options and basic signals, then click Add.
To make changes, click it in the list box, make the desired changes and
click Change or Delete.
VE432
The Acquisition Type setup >
640 428XL Users Manual Vol. 1
April 11, 2013
12
To save the current list of acquisition types, click Apply. (To revert to
the former list, click Reset instead).
VE432
The Radio Management setup >
428XL Users Manual Vol. 1 641
April 11, 2013
12
The Radio Management setup
Figure 12-14
Get DSD Status
This option button allows you to choose the moment when each DSD
should transmit its status to the DPG, and to choose a return signal:
- During the sweep: the DSD will transmit its status during the
next sweep rather than in the interval between two successive
sweeps. This allows you to save time, but prevents you from
using a Return Sweep.
- At end of sweep: the DSD will transmit its status at the end of
sweeps. Choose this option if you wish to use a Return Sweep.
(The Return Sweep is transmitted by a DSD to the DPG during
sweeps via the radio link).
Return Signal
This button allows you to specify whether to use a Return Sweep signal.
If you tick this option, then you have to specify the vibrator on which
the Return Sweep signal is to be picked up, choose which signal to pick
up as the Return Sweep on this vibrator, and also choose a Return Pilot.
The Return Sweep is transmitted by the DSD to the DPG during sweeps
via the radio link. As a result, if you choose to use a Return Sweep, the
DSD status cannot be transmitted to the DPG during sweeps (see Get
DSD Status option above).
Vib. 2
Vib. 3
Vib. 10
VE432
The Radio Management setup >
642 428XL Users Manual Vol. 1
April 11, 2013
12
The Return Sweep and Return Pilot are relayed to the central unit via
the DPG's Analog Pilot connector.
Return Sweep On Vib #
Return Sweep refers to a signal sensed on a vibrator's mechanical parts
and transmitted on the radio link to the DPG, for real-time monitoring
of the vibration source on the central unit. You have to click in the list
box to select (highlight) the vibrator to be monitored.
Signal
This option button allows you to choose which signal to monitor as
Return Sweep from six possible options:
Force: Ground force signal
Macc: Mass acceleration
Mvel: Mass velocity
Bacc: Base plate acceleration
Bvel: Base plate velocity
Ref: DSD local reference
Return Pilot
If you select a Return Sweep, you have to select a Return Pilot, that is
one of the Pilot signals generated by the DPG, shifted by the radio delay,
so that it can be used as reference signal by the correlation processor.
Choose a Return Pilot from the Pilot signals (P1 to P4) specified in the
The Acquisition Type setup (page 637).
Note For radio similarity tests:
the Return Pilot should be fed to Auxiliary channel 2.
the Return Sweep should be fed to Auxiliary channel 3.
VE432
The Radio Management setup >
428XL Users Manual Vol. 1 643
April 11, 2013
12
Generating a Radio Management Setup
1. Select the appropriate Get DSD Status option.
2. If you want to define a Return Signal:
- Tick the Return Signal option,
- Click in the list box to select (highlight) the vibrator you want to
monitor (choose a vibrator that responded successfully to the
Look function),
- From the Signal option button, select the signal to monitor
(Force/Mass acceleration/etc.),
- Choose a Return Pilot (P1/P2/P3/P4),
3. To save and enable your changes, click Apply. (To revert to the
former settings, click Reset instead).
VE432
The QC Limit setup >
644 428XL Users Manual Vol. 1
April 11, 2013
12
The QC Limit setup
Figure 12-15
This dialog box allows you to set alert thresholds for some of the
Quality Control data supplied to the GUI by the DSDs. Any threshold
being exceeded will cause the QC data of the DSD to be displayed in
orange in the main window.
Average Phase Error: 0 to 45 degrees.
Maximum Phase Error: 0 to 45 degrees.
Average Distortion:0 to 50%.
Maximum Distortion: 0 to 80%.
Average Ground Force: 0 to 100%.
To save and enable your changes, click Apply. (To revert to the former
settings, click Reset instead).
VE432
The QC Choice setup >
428XL Users Manual Vol. 1 645
April 11, 2013
12
The QC Choice setup
Figure 12-16
To save and enable your changes, click Apply. (To revert to the former
settings, click Reset instead).
Data Computation Domain
(Time or Frequency) This option button is used to specify whether
the DPG should output the vibrator QC data in the Time domain (phase
error, distortion, ground force) or in the Frequency domain (phase
error, ground force).
Extended QC
If you select this option, QC data computed every 0.5 second, can be
viewed in real time (i. e. with Auto activated), using the Get QC
function. The average QC results computed over a complete acquisition
are still available.
(If you do not select the Extended QC option, the Extended QC data is
still computed but it cannot be viewed during acquisitions).
VE432
The T0 Time setup >
646 428XL Users Manual Vol. 1
April 11, 2013
12
The T0 Time setup
Figure 12-17
The T0 time (or T0 sync code) is a virtual time mark signal
terminating every T0 message (message radioed between the DPG and
DSDs).
The T0 sync code is used for:
- measuring the radio delays,
- allowing the DSDs to start their sweeps at the same time.
See also Radio functions (page 662).
To save and enable your changes, click Apply. (To revert to the former
settings, click Reset instead).
T0 Repeat Times
(Allowable range: 2 to 50).
Specifies the number of T0 data frames in the T0 message. It may be
helpful to send more than 2 T0 data frames to increase the reliability of
the radio link. However, repeating the T0 data frame causes the T0 sync
code (terminating the T0 message) to be delayed with respect to the
transmit start time of the DPG radio. The delay may be:
up to 50x311 ms =15.5 s at 1800 bits/s (base band transmitter)
or
up to 50x467 ms =23.3 s at 1200 bits/s (modem module transmitter).
VE432
The T0 Time setup >
428XL Users Manual Vol. 1 647
April 11, 2013
12
T0 Mode
(Normal T0 or Early T0) Allows you to set the transmit start time
of the DPG radio between any two consecutive acquisitions.
In the Normal T0 mode, the DPG radio is not switched to
transmission until the DPG receives the Firing Order.
In the Early T0 mode, the DPG radio is switched to transmission
right after the DSD status report is received, irrespective of the
expected Firing Order for the next acquisition. The time interval
between any two acquisitions is therefore shorter by about 1.7
seconds if the Early T0 mode is used.
FO Window
(Allowable range: 3 to 60 seconds).
Must be specified if the Early T0 mode is selected. Stands for a time
interval, starting right after the DSD status report is received, during
which the Firing Order for the next acquisition is expected.
If no Firing Order is received within the FO window, then the system
will return to the normal T0 mode for the next acquisition.
VE432
The Pattern setup window >
648 428XL Users Manual Vol. 1
April 11, 2013
12
The Pattern setup window
The pattern setup window allows you to define the geometry of a
Vibrator Point, by specifying the position of each vibrator with respect
to the Centre Of Gravity of the source point. The pattern description is
required for the Guidance function.
Figure 12-18
To generate a pattern description, do the following:
1. Use the Pattern Nb option button to choose an identification
number for the type of pattern.
2. Use the Nb of Vib option button to specify the number of
vibrators in the pattern.
3. Adjust the position of each vibrator in the pattern as required, by
dragging the vibrator point in the graphic view or specifying the
appropriate delta X and delta Y offset with respect to the
Drag to adjust
Vib position
Numeric description
of pattern
Number of vibrators
in pattern
Pattern type
identification
number
Planned
source COG
Metres
or Feet
Graphic view of
pattern
1
2
3
4
p1 p2
p4 p3
0.5
-0.5
-0.5
0.5
0.5
0.5
-0.5
-0.5
VE432
The Pattern setup window >
428XL Users Manual Vol. 1 649
April 11, 2013
12
planned COG, in metres or feet (you can select whichever you like
from the Unit button).
4. Set the rotation and source line parameters:
Pattern rotation: (dddmmss.ss) use this field to rotate the pattern as
required. (The vertical axis of the pattern in the graphic view always
points to the true North).
Figure 12-19
Stack distance: distance to the next shake location within a stacked
VP, for each vibrator (i. e. source station spacing).
(-0600000.00)
-60
p1
p2
p4
p3
p1
p2
p4
p3
(0450000.00)
45
-60
45
p1
p4
p3
p2
p1
p2
p4
p3
VPn VPn+1
VPn
VPn+1
(0450000.00)
45
p1
p2
p4
p3
45
p1
p2
p4
p3
VPn+1
VPn
True North
VP geometry
Pattern
Rotation
Pattern
Setup
True North
VE432
The Pattern setup window >
650 428XL Users Manual Vol. 1
April 11, 2013
12
Figure 12-20
With an even stacking fold, the VP is located midway (half the stack
distance) between the two centremost source stations as shown
below.
Figure 12-21
Stack Source Line Bearing: Bearing of the direction in which to
steer each vibrator to its next shake location within a stacked VP.
See the examples below.
12 m
VPn
12 m
Stack distance: 12 m , Stacking fold: 3
Source
Line
6 m
12 m 12 m
6 m
VPn
Stack distance: 12 m , Stacking fold: 4
Source
Line
VE432
The Pattern setup window >
428XL Users Manual Vol. 1 651
April 11, 2013
12
Figure 12-22
Figure 12-23
p1
p2
p4
p3
45
p1
p2
p4
p3
12 m
90
p1
p2
p4
p3
p1
p2
p4
p3
VPn
VPn+1
Pattern Rotation: 45, Stack Source Line Bearing: 90, Stack distance: 12 m , Stack fold: 2
True North
Source
Line
Stack
distance
1
2

m
p1
p2
p4
p3
-60
p1
p2
p4
p3
45
p1
p2
p4
p3
p1
p2
p4
p3
VPn+1
V
P
n
+
1
V
P
n
Pattern Rotation: -60, Stack Source Line Bearing: 45, Stack distance: 12 m , Stack fold: 2
True North
VE432
Functions > Auto/Manual
652 428XL Users Manual Vol. 1
April 11, 2013
12
Functions
In this section:
Auto/Manual (page 652)
Look (page 653)
Vibrator Fleet (page 655)
Local Acquisition (page 657)
Set DSD (page 658)
Get DSD (page 659)
Radio functions (page 662)
Set Servo (page 667)
PCMCIA Tools (page 669)
Auto/Manual
Figure 12-24
Clicking Manual isolates the DPG from the 428XL and enables its
local functions (e.g. local acquisition). As a result:
data acquisition in vibroseismic operations is suspended until the
DPG is reset to Auto.
the traffic light of the DPG in the 428XL Activity window turns red.
Clicking Auto connects the DPG to the 428XL (and checks the DSD
Setup parameters) allowing it to perform data acquisition (if the VE432
window is ready, with consistent parameter settings, and if the Vib Fleet
function has been completed). With Auto activated, DPG local
VE432
Functions > Look
428XL Users Manual Vol. 1 653
April 11, 2013
12
functions are inhibited; the traffic light of the DPG in the 428XL
Activity window is green during sweeps, orange otherwise.
Look
The Look DSD function
allows you to select the
DSDs to be used in the active
crew.
You must have used the
Setups menu's Crew
command to define a crew (a
list of DSDs). The crew
consisting of all the DSDs
that you select through the
Look DSD function is
referred to as the active
crew. Selecting a DSD with the Look DSD function means
initializing the radio transmission between the DPG and this DSD and
querying to see if its status is correct.
Prerequisites
Unless already done, click the Manual button in the control panel to
isolate the DPG from the recording unit.
All the DSDs you intend to select must be in the Remote state (use
the Remote key on the DSD).
You cannot use the Look button (i. e. the button is dimmed) until the
DPG is connected to the computer and powered up (communication
between the two must be established).
Select
1. Using the right arrow button, move the vibrators you want to
initialize (those which are to make up the active crew) from the
Figure 12-25
VE432
Functions > Look
654 428XL Users Manual Vol. 1
April 11, 2013
12
left-hand list (Available DSDs) to the vibrator list for the desired
DPG controller module.
2. Click the Select button. As a result, a message is radioed to all the
DSDs chosen in the right-hand list box, thus initializing or re-
initializing radio communications between the DPG and those
DSDs.
3. All the DSDs that replied successfully are displayed with boldface
characters in the Look DSD dialog box's vibrator list. In the case
of a multimodule configuration, there is one list for each DPG
module:
Figure 12-26
- The vibrator indicators should turn orange, unless the vibrator
parameters need to be loaded.
- The indicator of any vibrator that requires parameters to be
loaded is shown in blue and the message DSD#.. Wrong setup
DSD table appears. (Use the Set DSD function to load the
parameters).
- If the Vib Fleet function has been performed, those DSDs which
are seen by Look and associated with a fleet are shown in green.
- Any DSD that requires the Installation or Initialization routine to
be performed is shown in red.
- Any DSD for which the Look function failed is colorless.
4. If any DSD (Vib xx) fails to reply properly, e. g. because it is not
installed or because of radio-communications problems, then the
The vibrator status bar in the
main window is updated
VE432
Functions > Vibrator Fleet
428XL Users Manual Vol. 1 655
April 11, 2013
12
message No answer from DSD xx Do you want to retry?
appears in a warning dialog box.
Append
Same as Select button, but those DSDs which were initialized when the
Look DSD function was last executed are not re-initialized, so they
remain selected. Therefore, the Append button allows you to add one
or more DSDs to the list of selected DSDs without re-initializing the
whole list.
Vibrator Fleet
A crew may consist of up to 4 groups of DSDs referred to as
fleets (one fleet for each vibratory source). The Vib. Fleet
function is used to specify the DSDs incorporated in each
fleet. Beforehand, you have to run the Look and Set DSD functions.
Clicking theVibrator Fleet button opens a dialog box with a list box for
each fleet in the crew. (To specify which fleets are to be used in the crew,
see The Vibrator Crew setup on page 618).
Figure 12-27
The left-hand list box (Available DSDs) prompts the list of DSDs
available to the crew, i. e. those selected by the Look function but not
assigned to any fleet yet. Using the right arrow button (or the usual drag
and drop method), move the vibrators you want to incorporate into a
fleet from the left-hand list box to the desired fleets list box.
Vib
Number
Vib. 2 1
Vib. 3 R 2
Leader
Vib. 10
Vib. 12
Position in
Pattern
VE432
Functions > Vibrator Fleet
656 428XL Users Manual Vol. 1
April 11, 2013
12
If the Guidance option is used, the first vibrator (DSD) you enter into a
fleets list box is assigned to Position 1 in each pattern, the second to
Position 2, etc. In the above example, Vibrator No. 3 is assigned to
Position 2 in each pattern, Vibrator No. 2 is assigned to Position 1. See
The Pattern setup window (page 648).
Double-clicking on any DSD in the list enables or disables the use of the
Ready button on this DSD (this also determines which vibrator is the
leader). Pushing the Ready button on any DSD is of no effect unless the
button is enabled in the Fleet window. (An R appears after the DSD
number of the leader in the list box, meaning that the use of the Ready
button on this DSD is enabled).
After selecting (highlighting) the
desired DSDs in each fleet's list
box, clicking Go will update the
status bar displayed under the
function buttons in the main
window: a flag appears ahead of
each vibrators fleet in the status bar,
and those vibrators which are ready
in each fleet are shown in green.
Note After enabling or disabling the Guidance option in the
Operation window, you have to go to Manual and run again the
Set DSD and Vib Fleet functions.
The green colour means the
vibrator is ready to be used in
remote control mode
Figure 12-28
VE432
Functions > Local Acquisition
428XL Users Manual Vol. 1 657
April 11, 2013
12
Local Acquisition
This function allows you to check the vibrator equipment
separately, as if it were not connected to the recording unit.
For a local acquisition the DPG may operate alone, or the
DPG and DSDs may operate normally but without being controlled by
the recording unit. In that case the Blast command (Firing Order) is
replaced by a manual start (Go pushbutton).
Prerequisites
Unless already done, click the Manual button in the control panel to
isolate the DPG from the recording unit.
The DSDs that you want to use must be selected (see Look on
page 653), with consistent parameters.
How to use the local acquisition function
1. Click the Local Acquisition function button. A dialog box
appears showing the DSDs currently selected in the active crew.
Figure 12-29
2. In the list box, choose (by clicking) the vibrators you wish to use
for the local acquisition. If you do not select any vibrator, then the
DPG will operate alone.
3. In the Basic Type field, enter the type of basic signal you wish to
use. (Basic Types are defined through the Setups menu).
4. Click the option button to choose the execution mode:
VE432
Functions > Set DSD
658 428XL Users Manual Vol. 1
April 11, 2013
12
Single: The basic signal is generated once.
Continuous: The basic signal repeats endlessly until you click the
Stop button (which appears at the bottom of the dialog box if you
choose this option).
5. Click the Go button. The local acquisition executes. In Single
mode, the local acquisition ends automatically, without any user
action. In Continuous mode, you must click the Stop button to
interrupt the local acquisition, which will actually stop after the
current acquisition is complete.
Set DSD
This function is used to upload sweep-type parameters from
the DPG to the DSDs you specify.
The sweep parameters are read from the table containing all the
acquisition types (ACQ#) defined in the VE432 window. They are
required in the DSDs for generating the corresponding vibratory
sources. The Set DSD function allows you to have consistent
parameters in all the DSDs to be used for a sweep. Those DSDs which
have inconsistent parameters are shown in blue in the main window's
status bar.
Prerequisites
Unless already done, click the Manual button in the control panel to
isolate the DPG from the recording unit.
The DSDs to which you want to upload sweep type parameters must be
selected. See Look (page 653).
How to use the Set DSD function
1. Click the Set DSD pushbutton in the control panel. A dialog box
appears with a list box showing the DSDs currently selected in the
active crew (as a result of the Look DSD function).
VE432
Functions > Get DSD
428XL Users Manual Vol. 1 659
April 11, 2013
12
Figure 12-30
2. In the list box, select (by clicking) the vibrators you wish to load
parameters to.
3. Click the Go button.
Note With a customized basic signal (Custom option in Basic Type
setup), errors may appear at this stage as the Set DSD function
checks for consistent parameters from the custom file.
Get DSD
This function is used to import and view the vibrator
parameters from one or more DSDs you specify.
Prerequisites
Unless already done, click the Manual button in the control panel to
isolate the DPG from the recording unit.
The DSDs that you want to query must be selected. See Look
(page 653).
How to use the Get DSD function
1. Click the Get DSD button. A dialog box appears with a list box
showing the DSDs currently selected in the active crew (as a
result of the Look DSD function).
The orange colour means
the DPG and DSD
acquisitions are matching
Vib. 1
Vib. 2
Vib. 3
VE432
Functions > Get DSD
660 428XL Users Manual Vol. 1
April 11, 2013
12
Figure 12-31
2. In the list box, choose (by clicking) the vibrators you wish to get
parameters from.
3. Select the type of units you wish to use to display the results:
Metric (kg, daN, etc.) Imperial (lb, lbf, etc.).
4. Click the Go button.
After all the data from the DSDs have been collected they are viewed in
a table so that comparisons between DSDs can be made easily.
DSD parameters
Running the Get DSD function opens a view pane displaying the
following vibrator parameters from each selected DSD:
Vib. 1
Vib. 2
Vib. 3
VE432
Functions > Get DSD
428XL Users Manual Vol. 1 661
April 11, 2013
12
Figure 12-32
Results from the two sweeps that
were used for the identification process.
100 to 32767 kg
100 to 32767 kg
100 to 32767 kg
1000 to 327670 daN
1000 to 327670 daN
Polarity (depending on the wiring) of the
Reaction Mass, Servo Valve, Torque Motor.
Gain of the Mass LVDT and
Valve LVDT (Linear Variable Differential Transformer)
- Reaction mass LVDT offset
- Main Valve LVDT offset
- Torque motor current
- Active region of LVDT stroke, in percent.
- Static gain of pilot valve.
- Pilot valve cut-off frequency
- Pilot valve damping coefficient
- Value of leakage between the two chambers of the reaction mass.
- Main valve static gain
- Gain weighting in the servo control loop.
- Servo control type (Filtered or Raw).
- Amplitude level (0 to 100%) for the DSD's DRIVE "H" key.
- Amplitude level (0 to 100%) for the DSD's DRIVE "L" key.
- If Auto Level =Yes, Minimum high drive level, in percent.
- If Auto Level =Yes, Minimum low drive level, in percent.
VE432
Functions > Radio functions
662 428XL Users Manual Vol. 1
April 11, 2013
12
Radio functions
Radio functions are used to measure (Compute Radio
Delay) or manually change (Modify Radio Delay) the
radio delay inherent in radio transmissions between the
DPG and DSDs, or to remotely change the radio output levels of the
DPG and DSDs (Set Radio Parameters).
Figure 12-33
The radio delay is an essential parameter in the correlation process as it
is involved in making the pilot signal synchronous with the sweep
signal.
A radio delay is usually measured for a given type of radio transceiver.
The Compute function should therefore be run whenever you use a new
radio type on your DPG and DSDs, but also at regular time intervals to
check the performance of your radio sets. Through the Compute
function, a series of five measurement sequences is run to determine the
radio delay.
The Radio Delay can also be typed on the computers keyboard (using
the Modify function) for example because you want to use a value
slightly different from the average radio delay determined by the
Compute function.
The Set Radio Parameters tab is used to set the transmission output
level of the radio units of the DPG and DSDs.
Prerequisites
Unless already done, click the Manual button in the control panel to
isolate the DPG from the recording unit.
Use the Look DSD function to define your active crew.
VE432
Functions > Radio functions
428XL Users Manual Vol. 1 663
April 11, 2013
12
How to use the Compute function
1. Click the Compute Radio Delay tab. The DPG queries the
selected DSDs in succession, via the radio link, based on the
scheme described below. See More about the radio delay
measurement (page 664).
2. After the radio delay is determined, the DPG radio delay assumes
the determined value and, via radio transmissions from the DPG,
all corrections to the extra delay are zeroed in the DSDs. For more
information on this parameter, see More about the radio delay
(page 666).
3. After transmission is complete, the computed radio delay appears
in the Dpg Radio Delay field, meaning that the Compute
function is complete.
Transmission faults
If the DPG fails to receive a reply from any DSD (a T0 sync on its return
trip is expected), the warning message No T0 reception shows up in
the status pane.
In that case, the DPG will resume the transmission of T0 to this DSD.
If the retry is successful (a reply is received), the function will proceed
normally unless a total of 8 retries have already been done since the
Compute function was initiated, in which case the function is aborted,
as a more severe failure is suspected, and the Measurement aborted
(radio trans. errors) warning message shows up.
How to enter a radio delay (Modify function)
1. Click on the Modify Radio Delay tab.
Figure 12-34
VE432
Functions > Radio functions
664 428XL Users Manual Vol. 1
April 11, 2013
12
2. In the DPG Radio Delayfield, enter the value of radio delay
that you want to use.
3. Click Go to activate this value.
You cannot enter an individual radio delay for each DSD.
Setting radio parameters
Click on the Set Radio Parameters tab.
Figure 12-35
The Radio Level is adjustable from 3% (min) to 100% (max).
Number of Ready Frames: typically, a single ready message is
required. In the event of difficult radio transmission conditions
(important interference or jamming), repeating the ready message
may help.
Radio Transmission Delay: set as required, depending on the radio
model used. See the VE432 manual.
Clicking Go uploads the selected value to all DSDs and Slave DPGs
selected by the Select or Append function (Look DSD), and all DPGs.
More about the radio delay measurement
Measurement principle
Radio delays are measured using the T0 sync code. This signal is the
pseudorandom code transmitted in the T0 message.
VE432
Functions > Radio functions
428XL Users Manual Vol. 1 665
April 11, 2013
12
Measurement sequences
A measurement sequence may be outlined as follows:
A T0 message is transmitted from the DPG.
Upon receiving the T0 sync code, a DSD must transmit this time
mark back to the DPG.
The same DSD transmits the t2 time to the DPG.
The DPG determines a solution (D1) for the radio delay through the
following formula:
where
t1 =elapsed time between the moment the DPG transmits the T0
and the moment it receives it back from a DSD.
t2 =elapsed time between the moment the DSD receives the T0
from the DPG and the moment it transmits it back to the DPG.
The measurement sequence is repeated until five measurements (D1,
D2, ..., D5) are available on the DPG, irrespective of the number of
DSDs in the crew. DSDs are queried in ascending order of fleet#and
vibrator#.
If for example the crew consists of six DSDs, the five solutions are
obtained from:
Vib 1 (Fleet 1) D1
Vib 2 (Fleet 1) D2
Vib 3 (Fleet 2) D3
Vib 4 (Fleet 2) D4
Vib 5 (Fleet 3) D5
Vib 6 (Fleet 3) not queried
But if there are only two DSDs, the five solutions are obtained from:
Vib 1 (D1)
D1
t1 t2
2
---------------- =
VE432
Functions > Radio functions
666 428XL Users Manual Vol. 1
April 11, 2013
12
Vib 2 (D2)
Vib 1 (D3)
Vib 2 (D4)
Vib 1 (D5).
Radio delay, final result
The radio delay is then computed by averaging the five solutions. The
expression of the final result is then:
(Typical value with standard radios: 500 microseconds approx.)
More about the radio delay
Definition
The radio delay may be defined as the time elapsed between the
moment a command intended for a DSD is requested on the DPG and
the moment it starts running on the DSD, that is the propagation time of
a message from the DPG to a DSD via the radio.
System requirements
A record sequence requires that all pilots and sweeps should start at
exactly the same time.
If no provision were made for synchronous start times, a Firing Order
transmitted from the DPG at time t would result in a premature
generation of pilots, or in a delayed generation of sweep start times, due
to the delay introduced by the radio sets.
How the system can generate synchronous pilots and sweeps
Pilots are postponed by a time delay, starting from the T0 sync code, in
order to compensate for the radio delays: all pilot start times are
postponed by a time equal to the radio delay, computed or user-set, to
match the sweep start time (affected by the radio delay) in the DSDs.
RadioDelay
D1 D2 D3 D4 D5 + + + +
5
---------------------------------------------------------------- =
VE432
Functions > Set Servo
428XL Users Manual Vol. 1 667
April 11, 2013
12
Set Servo
This function allows you to set the parameters used in each vibrator's
servo control loop. Clicking Go will set the servo control loop
parameters of all the vibrators you select (highlight) in the list box.
Figure 12-36
Prerequisites
Unless already done, click Manual in the control panel to isolate the
DPG from the recording unit.
The DSDs that you want to set must be selected (see page 653 - Look
DSD function).
Servo Input
This option button determines what to use as input to the servo control:
either the estimated states from the Kalman filter (Filtered option) or
raw measurements of baseplate and mass accelerations (Raw option).
Filtered: using this option allows the system to discard non-coherent
measurements on any sensor (baseplate acc., mass acc., valve or mass
LVDTs). Remember that the QC and the usual way of testing the
equipment with external devices always involve the force derived
from raw acceleration measurements. Therefore, in the presence of
vibrator imperfections (e.g. mass rocking & baseplate flexure) a raw
Vib. 1
Vib. 2
Vib. 3
VE432
Functions > Set Servo
668 428XL Users Manual Vol. 1
April 11, 2013
12
QC can exhibit larger errors than the real performance of the servo
loop.
Raw: with this option, servo control and QC are homogeneous but
the system cannot benefit from the capability of discarding incorrect
measurements. This option is of no effect on a random sweep.
Auto Level
This button allows you to enable or disable the Auto Level function. If
you enable the Auto Level function, then you must specify lower limits
for both High and Low drive levels.
DSDs using the Auto Level function operate as follows:
The Drive level is decreased for the next sweep if an overload
condition is detected. However the drive level cannot go below the
values of Min High Drive and Min Low Drive.
The Drive level is increased for the next sweep if no overload
condition is detected. However the drive level cannot exceed the
values of High Drive Level and Low Drive Level.
DSDs not using the Auto Level function will operate only within the
limits of High Drive Level and Low Drive Level.
Low Drive Level
Lower amplitude, in percent, of drive level. The scale is adjustable from
0 to 100% in 1% steps.
Requirements: Low Drive Level <High Drive Level.
High Drive Level
Upper amplitude, in percent, of drive level. The scale is adjustable from
0 to 100% in 1% steps.
Min Low Drive
This scale appears only if Auto Level is selected.
VE432
Functions > PCMCIA Tools
428XL Users Manual Vol. 1 669
April 11, 2013
12
Low limit of Low Drive Level, in percent. The scale is adjustable from
0 to 100% in 1% steps.
Requirements: Min Low Drive <Low Drive Level.
Min High Drive
This scale appears only if Auto Level is selected.
Low limit of High Drive Level, in percent. The scale is adjustable from
0 to 100% in 1% steps.
Requirements: Min High Drive <High Drive level.
Lift Up Delay
Time interval between the end of a sweep and the moment when a
vibrator's pad will lift if Auto Lift is enabled. Adjustable from 0 to
99seconds.
If no delay is required, set the Lift Up Delay to 0.
PCMCIA Tools
This function opens a dialog box that allows you to save a software
release or file to a PCMCIA card, via the PCMCIA card drive available
on a DPG, so that it can be loaded to a DSD.
Figure 12-37 PCMCIA Tools
VE432
Functions > PCMCIA Tools
670 428XL Users Manual Vol. 1
April 11, 2013
12
You are not allowed to launch any these PCMCIA functions unless you
go to Manual.
Use the Module option button to specify which DPG you want to use to
write to the PCMCIA card (because up to four DPGs may be attached
to the network, for example if you are working in Slip-Sweep mode).
The identification number of a DPG is determined by the system. It is
displayed when you run the Look function.
Choose the desired option and then click Go to launch the function. The
DPG will return a message in the status mail window when the
command is complete. Some commands may take a while to execute, so
be patient.
Load Husky file
This command is only intended for a Husky handheld computer. It is
used to load the latest version of Husky software to the handheld
computer. You have to connect the handheld computer to the DPG
(COM 1 port) and then type the following command (and press Return)
on the handheld computers keypad:
load
Then a message on the handheld computer tells you it is waiting for
downloading.
(With later handheld models, software is loaded from the SERCEL
CD-ROM via a PC).
Load DPG slave file to PCMCIA
Used to load the latest version of Slave DPG software to a PCMCIA
card. You have to insert a PCMCIA card into the DPG.
Load DSD file to PCMCIA
Used to load the latest version of DSD software to a PCMCIA card. You
have to insert a PCMCIA card into the DPG.
VE432
Functions > PCMCIA Tools
428XL Users Manual Vol. 1 671
April 11, 2013
12
Format PCMCIA
Used to format the PCMCIA card inserted in the DPGs drive.
Load DPG file to PCMCIA
Used to load DPG boot ROM software to a PCMCIA card. DPG boot
ROM software may be necessary, for example, if you wish to use a
DVC board in a DPG.
Load custom file to PCMCIA
Used to load a file containing custom sweep samples to a DPG. See
Custom (page 631).
VE432
Normal acquisition > General
672 428XL Users Manual Vol. 1
April 11, 2013
12
Normal acquisition
In this section:
General (page 672)
Graphic view (page 673)
Numeric view (page 676)
DPG/DSD status codes (page 678)
General
The DSDs that you want to use for normal acquisition must be
selected. See Look (page 653), with consistent parameters (i. e. each
DSD to be used should appear with a green indicator in the main
window's status bar).
When you are ready for a normal acquisition, click the Auto button, in
the main window's control panel. As a result the DPG is waiting for the
Firing Order from the 428XL.
The 428XL will not generate the F O until it receives a Ready status
from the DPG window. When the Ready signal is received from the
vibrator fleet leader, that is when all the desired vibrators are in place
with pads down, it may be retained in the DPG window or automatically
relayed to the recording system, depending on whether the fleets button
in the status bar is released or depressed.
When it receives the F O the DPG generates the Time Break to the
selected DSDs. Then the programmed sweeps are taken and all DSDs
in turn transmit their latest status reports, corresponding to one or more
completed sweeps, to the DPG.
The Status and QC data generated by the DPG are relayed to the GUI
via the Ethernet link and stored into a daily file automatically generated
in the Log window and named normalAcqResult.hci428_0.ddd
where ddd stands for the julian day when the file was created. (They can
be viewed in the Log main window).
VE432
Normal acquisition > Graphic view
428XL Users Manual Vol. 1 673
April 11, 2013
12
QC and status results are not only saved but also displayed in the VE432
main window which makes it easy to appreciate the quality of a vibrator
in real time or through statistical post-processing. The results can be
presented in numeric or graphic form.
The colour of the QC data depends on the alert thresholds you set using
the DSD limits command in the Setup menu.
The radio link allows the DPG to see if any DSD failed to sweep for any
T0. In that case the DPG will report a 98 status (no T0 received).
For each status report received the DPG checks to see if the DSD and
DPG clock frequencies are the same. If that is not the case it replaces
the current status by a Timing Error (status 19).
If the Extended QC option is enabled (see The QC Choice setup on
page 645), the QC data can be plotted in real time in the results pane by
clicking the Get QC function button. To revert to the normal view, click
the Vibrator Fleet function button.
Graphic view
The VP and Acq fields respectively display the Vibrator Point number
and Acquisition number the results relate to.
Six bar charts are shown, for the following QC data available in the
status messages from the DSDs: Average Phase, Peak Phase, Average
Distortion, Peak Distortion, Average Ground Force, Peak Ground
Force.
A red horizontal line in each chart shows the limit specified in the Setup
menu (QC Limitcommand).
VE432
Normal acquisition > Graphic view
674 428XL Users Manual Vol. 1
April 11, 2013
12
Figure 12-38
For each DSD used, each chart shows:
A green or orange bar showing the QC value for the latest acquisition
completed (identified in the Acq field):
- Green if the QC value is below the limit,
- Orange if it exceeds the limit or an error is reported:
OV for an overload,
W for a warning,
T for a timing error.
F for a file error.
Average values over
the latest 50 sweeps
QC value during this
sweep
VE432
Normal acquisition > Graphic view
428XL Users Manual Vol. 1 675
April 11, 2013
12
- If the status code from any DSD is incorrect it is displayed in
place of the corresponding QC value.
A blue or red bar showing the average QC value over the latest 50
acquisitions:
- Blue if the average QC value is below the limit,
- Red if it exceeds the limit.
- If the status code from any DSD is incorrect it is displayed in
place of the corresponding QC value.
For the interpretation of Status codes, see page 678.
VE432
Normal acquisition > Numeric view
676 428XL Users Manual Vol. 1
April 11, 2013
12
Numeric view
A table is displayed, derived from the QC reports of the latest 50
acquisitions. For each DSD, the table shows:
the Vibrator Point number and the Acquisition number,
the Average/Peak Phase, or Distortion or Ground Force, or the Status
Code, whichever you choose from the QC option button.
Figure 12-39
VE432
Normal acquisition > Numeric view
428XL Users Manual Vol. 1 677
April 11, 2013
12
The colour of each cell in the table should be interpreted as follows:
If you choose the Status Code view:
- White background, black writing: QC values are within the
limits.
- White background, orange writing:
- status code 1 or 12 appears, QC values are within the limits but
an Overload and/or Warning has been reported.
- or status code 19 appears.
- White background, nothing displayed: no response from the
DSD.
- Orange background, black writing:
Status codes 1 or 12, or 19 appears, one of the QC values exceeds
the limits, no Overload, and no Warning.
- Orange background, white writing:
Status codes 1 or 12, or 19 appears; one of the QC values exceeds
the limits and an Overload and/or Warning is reported.
- Red background, white writing: if any other status appears.
If you select any of theQC views, the colours should be interpreted in
the same way, but only the selected QC is tested for compliance with
the limit.
For the interpretation of Status codes, see page 678.
Double-clicking in any cell opens a secondary window showing the
detailed QC values contained in the status report from the
corresponding DSD for the corresponding acquisition (see Figure 12-39
on page 676).The following codes may be reported for overloads:
F Raw ground Force reaches hold-down weight.
P Computed Pressure reaches maximum hydraulic pressure.
M Mass position exceeds usable stroke.
V Valve spool position exceeds usable stroke.
VE432
Normal acquisition > DPG/DSD status codes
678 428XL Users Manual Vol. 1
April 11, 2013
12
E Torque motor current, computed, exceeds maximum allowed
current.
The DSD status reports are logged into the database. They can be
viewed in the Log main window and saved to a file.
DPG/DSD status codes
1 Normal completion with Servo Input =Raw.
2 Sweep aborted by DSD. Hardware malfunction (DVC).
10 User abort.
11 Normal completion, Ethernet error between DSD and PC (cant
save force to disk).
12 Normal completion with Servo Input =Filtered.
13 Discrepancy in DPG and DSD acquisition tables. Use the Set
DSD function to correct the inconsistent table.
14 Lift not ready.
19 Normal, Timing error (indicative of discrepancy between DPG
and DSD clocks)..
20 HiLine error (Master DPG only).
21 Sweep #undefined.
22 Custom error (Custom sweep does not exist on PCMCIA card)
or can not read from PCMCIA card.
25 DPG time-out (Master DPG hardware failure).
26 The Slave recording unit failed to start (on a Slave DPG only).
98 No T0 data received (sweep failed to start, or radio malfunction).
99 No T0 data received or no status report (sweep failed to start or
DPG failed to receive consistent DSD status).
VE432
Statistics views >
428XL Users Manual Vol. 1 679
April 11, 2013
12
Statistics views
Whether for statistics on DSDs or on a fleet, the following distinct
views are available: average phase, peak phase, average distortion, peak
distortion, average ground force, peak ground force, Status Codes.
The system calculates the statistical data from the results collected since
it last went to Auto (meaning that your statistics views are lost each
time you go to Auto).
You can choose to view statistical data for each fleet or for each DSD.
Figure 12-40
Figure 12-41
VE432
Statistics views >
680 428XL Users Manual Vol. 1
April 11, 2013
12
In graphic Statistics views, the results are displayed in the form of a bar
chart for each vibrator (or for each fleet) plus a Vx (or Fleet X) bar chart
in the upper-left corner, showing the mean QC value computed on all
the DSDs (or all fleets).
Unless you choose the Manual range option, the horizontal scale is
automatically adjusted so that all samples can be shown. If you choose
Manual range, then the associated fields prompt the outermost values
of the horizontal scale, so that you can change them and adjust the scale
manually.
On each chart the horizontal axis is the scale (divided into a number of
bins) for the QC values (phase or distortion or force), and the vertical
axis is for the number of values in each bin. The following values are
also shown:
number of sweeps (n)
mean value (mean).
standard deviation (SDev), only in the zoom view.
See Bar charts (page 37).
428XL Users Manual Vol. 1 681
April 11, 2013
Chapter
13 Other vibrator electronics
This chapter includes the following sections:
The main window (page 682)
Working with other vibrator electronics (page 684)
Other vibrator electronics
The main window >
682 428XL Users Manual Vol. 1
April 11, 2013
13
The main window
To open the jVibOther window, click on this icon in the launcher
bar. It is only available if you choose Other as Vibrator type
(page 72) in the Install window.
Figure 13-1
This window allows you to set three parameters required for processing
the seismic data, and save each different setting of those parameters as
an Acquisition Type. You are required to choose which Acquisition
Type to use when you create a Process Type in the Operation main
window.
To create a new Acquisition Type, fill in the fields above the list box,
then click Add. To make changes, double-click on the desired row in the
list box, make the necessary changes and then click Add or Change or
Delete, as required.
To save and enable your changes, click Apply. (To revert to the former
settings, click Reset instead).
Sweep Length
Duration (seconds) of the sweep signal used as seismic source.
Other vibrator electronics
The main window >
428XL Users Manual Vol. 1 683
April 11, 2013
13
Pilot Length
Duration (seconds) of the signal used as reference in the correlation
process.
Sweep Length and Pilot Length are usually equal. For more
information see More About Correlation on page 396.
Threshold Type
The historical noise elimination process makes use of noise elimination
thresholds. The Threshold Type parameter is used to assign a type of
noise elimination threshold to each Acquisition Type (e.g. Threshold
Type #1). Acquisition types with the same length and the same energy
spreading can be associated with the same Threshold Type number.
(The maximum allowable number of Threshold Types is 16 whereas
you can create up to 32 different Acquisition Types).
Other vibrator electronics
Working with other vibrator electronics >
684 428XL Users Manual Vol. 1
April 11, 2013
13
Working with other vibrator electronics
To work with a vibrator system other than a VE432, you have to choose
that option in the Installation setup window (see Vibrator type on
page 72).
To connect the vibrator electronics to the LCI, see Connectors and
cables in the 428XL Installation manual.
428XL Users Manual Vol. 1 685
April 11, 2013
Chapter
14 Open Vibrator Controller
This chapter includes the following sections:
The main window (page 686)
The Vibrator Crew setup (page 687)
The Acquisition Type setup (page 688)
The QC Limit setup (page 690)
The Vibrator Fleet setup (page 691)
Normal acquisition (page 692)
Statistics views (page 696)
Open Vibrator Controller
The main window >
686 428XL Users Manual Vol. 1
April 11, 2013
14
The main window
The jOVC (Open Vibrator Controller) window is only available if you
choose the OVC Vibrator type (page 72) option in the jInstall window.
To open the Open Vibrator Controller main window, click on this
icon in the launcher bar.
This window serves as Graphic User Interface for other vibrator control
electronics than SERCELs VE464 or VE432.
Figure 14-1
The View menu and the associated toolbar allow you to customize the
main window by choosing one or more views to display. Then you can
resize your display panes by dragging the desired border.
You can show or hide columns in tables by right-clicking in any column
heading and selecting Customize (see Figure 2-25).
The Setups menu and the associated toolbar allow you to set parameters
for vibrator fleets and adjust QC parameters.
Note that a specific licence code is required in the jInstall window (OVC
Navigation field) to enable source navigation functions (Ready
indicator in jOperation windows Active Source view, fleet position in
jPositioning).
Setup toolbar
Click to show
view
Click to close view
Open Vibrator Controller
The Vibrator Crew setup >
428XL Users Manual Vol. 1 687
April 11, 2013
14
The Vibrator Crew setup
Figure 14-2
The Vibrator Crew setup dialog box is used to describe a seismic crew
by creating the list of vibrators to be controlled by the recorders GUI,
and creating the list of vibrator groups (fleets) to build.
To save the description of the crew, click Apply.
Clicking Reset instead of Apply reverts to the former settings.
Vib Id
This field is used to specify the identification number (1 to 32) of each
vibrator that the GUIs OVC main window has to control.
Fleet Id
This field is used to specify the identification number (1 to 4) of each
vibrator group to build.
Open Vibrator Controller
The Acquisition Type setup >
688 428XL Users Manual Vol. 1
April 11, 2013
14
The Acquisition Type setup
Figure 14-3
The Acquisition Type setup is used to set the following parameters for
the vibrators in a fleet:
Sweep Length
Duration (seconds) of the sweep signal used as seismic source.
Pilot Length
Duration (seconds) of the signal used as reference in the correlation
process.
Sweep Length and Pilot Length are usually equal. For more
information see More About Correlation on page 396.
Threshold Type
The historical noise elimination process makes use of noise elimination
thresholds. The Threshold Type parameter is used to assign a type of
noise elimination threshold to each Acquisition Type (e.g. Threshold
Type #1). Acquisition types with the same length and the same energy
spreading can be associated with the same Threshold Type number.
(The maximum allowable number of Threshold Types is 16 whereas
you can create up to 32 different Acquisition Types).
Open Vibrator Controller
The Acquisition Type setup >
428XL Users Manual Vol. 1 689
April 11, 2013
14
Acquisition Type & Label
The Acquisition Type field is used to enter an identification number
(1to 32) for the Acquisition Type. You will need that identification
number when you create a Process Type in the Operation window
(see The Process Type setup on page 256).
The Label field is used to enter a label (up to 16 ASCII characters) for
the Acquisition Type. A default label is prompted by the system (acq
type #) but you can enter a more user-friendly one.
To create a new acquisition type, enter its number in the Acquisition
Type field and then click Add. To make changes, click it in the list box,
make the desired changes and click Change or Delete as required.
To save the current list of acquisition types, click Apply. (To revert to
the former list, click Reset instead).
Open Vibrator Controller
The QC Limit setup >
690 428XL Users Manual Vol. 1
April 11, 2013
14
The QC Limit setup
Figure 14-4
This dialog box allows you to set alert thresholds for some of the
Quality Control data that the vibrators supply to the GUI. Any threshold
being exceeded will cause the QC data of the vibrator to be displayed in
orange in the main window.
Average Phase Error: 0 to 45 degrees.
Maximum Phase Error: 0 to 45 degrees.
Average Distortion: 0 to 50%.
Maximum Distortion: 0 to 80%.
Average Ground Force: 0 to 100%.
To save and enable your changes, click Apply. (To revert to the former
settings, click Reset instead).
Open Vibrator Controller
The Vibrator Fleet setup >
428XL Users Manual Vol. 1 691
April 11, 2013
14
The Vibrator Fleet setup
A crew may consist of up to 32 groups of vibrators, referred
to as fleets (one fleet for each vibratory source).
The Vib. Fleet setup displays a list box for each fleet you
created in The Vibrator Crew setup (page 687) so that you can specify
which vibrators are included in it.
Figure 14-5
The left-hand list box prompts the list of vibrators created in The
Vibrator Crew setup (page 687) but not assigned to any fleet yet. Using
the right arrow button (or the usual Drag and Drop method), move the
vibrators you want to incorporate into a fleet from the left-hand list box
to the desired fleets list box.
Click Apply to save your settings.
Open Vibrator Controller
Normal acquisition > General
692 428XL Users Manual Vol. 1
April 11, 2013
14
Normal acquisition
In this section:
General (page 692)
Graphic view (page 692)
Numeric view (page 694)
General
Clicking Go in the Operation window causes the LCI to generate the
Firing Order. As a result, the Vibrator Control Electronics (VCE) sends
a request to the server for vibrator parameters. After the VCE gets the
parameters from the server, it generates the Time Break. Then the
programmed sweep is taken and the VCE sends its vibrator status and
QC data to the server.
The Status and QC data generated by the VCE are relayed to the GUI
via the Ethernet link.
QC and status results are not only saved but also displayed in the OVC
main window which makes it easy to appreciate the quality of a vibrator
in real time or through statistical post-processing. The results can be
presented in numeric or graphic form.
The colour of the QC data depends on the alert thresholds you set using
the QC limits Setup menu.
Graphic view
The VP and Acq fields respectively display the Vibrator Point number
and Acquisition number the results relate to.
Six bar charts are shown, for the following QC data available in the
status messages from the vibrators: Average Phase, Peak Phase,
Average Distortion, Peak Distortion, Average Ground Force, Peak
Ground Force.
Open Vibrator Controller
Normal acquisition > Graphic view
428XL Users Manual Vol. 1 693
April 11, 2013
14
A red horizontal line in each chart shows the limit specified in the Setup
menu (QC Limitcommand).
Figure 14-6
For each vibrator used, each chart shows:
A green or orange bar showing the QC value for the latest acquisition
completed (identified in the Acq field):
- Green if the QC value is below the limit,
- Orange if it exceeds the limit or an error is reported:
- If the status code from any vibrator is incorrect it is displayed in
place of the corresponding QC value.
A blue or red bar showing the average QC value over the latest 50
acquisitions:
- Blue if the average QC value is below the limit,
- Red if it exceeds the limit.
Average values over
the latest 50 sweeps
QC value during this
sweep
Open Vibrator Controller
Normal acquisition > Numeric view
694 428XL Users Manual Vol. 1
April 11, 2013
14
- If the status code from any vibrator is incorrect it is displayed in
place of the corresponding QC value.
Numeric view
A table is displayed, derived from the QC reports of the latest 50
acquisitions. For each vibrator, the table shows:
the Vibrator Point number and the Acquisition number,
the Average/Peak Phase, or Distortion or Ground Force, or the Status
Code, whichever you choose from the QC option button.
Figure 14-7
The colour of each cell in the table should be interpreted as follows:
If you choose the Status Code view:
- White background, black writing: QC values are within the
limits.
- White background, orange writing: status code 1 appears, QC
values are within the limits but an Overload and/or Warning has
been reported.
- White background, nothing displayed: no response from the
vibrator.
- Orange background, black writing: status code 1 appears, one of
the QC values exceeds the limits, no Overload, and no Warning.
- Orange background, white writing: status code 1 appears; one of
the QC values exceeds the limits and an Overload and/or
Warning is reported.
Open Vibrator Controller
Normal acquisition > Numeric view
428XL Users Manual Vol. 1 695
April 11, 2013
14
- Red background, white writing, if any other status appears.
If you select any of theQC views, the colours should be interpreted in
the same way, but only the selected QC is tested for compliance with
the limit.
Double-clicking in any cell opens a secondary window showing the
detailed QC values contained in the status report from the
corresponding vibrator for the corresponding acquisition.
Open Vibrator Controller
Statistics views > Numeric view
696 428XL Users Manual Vol. 1
April 11, 2013
14
Statistics views
Whether for statistics on vibrators or on a fleet, the following distinct
views are available: average phase, peak phase, average distortion, peak
distortion, average ground force, peak ground force, Status Codes.
The system calculates the statistical data from the results collected since
it last went to Auto (meaning that your statistics views are lost each
time you go to Auto).
You can choose to view statistical data for each fleet or for each
vibrator.
Figure 14-8
Figure 14-9
Open Vibrator Controller
Statistics views > Numeric view
428XL Users Manual Vol. 1 697
April 11, 2013
14
Figure 14-10
In graphic Statistics views, the results are displayed in the form of a bar
chart for each vibrator (or for each fleet) plus a Vx (or Fleet X) bar chart
in the upper-left corner, showing the mean QC value computed on all
the vibrators (or all fleets).
Unless you choose the Manual range option, the horizontal scale is
automatically adjusted so that all samples can be shown. If you choose
Manual range, then the associated fields prompt the outermost values
of the horizontal scale, so that you can change them and adjust the scale
manually.
On each chart the horizontal axis is the scale (divided into a number of
bins) for the QC values (phase or distortion or force), and the vertical
axis is for the number of values in each bin. The following values are
also shown:
number of sweeps (n)
mean value (mean).
standard deviation (SDev), only in the zoom view.
See Bar charts (page 37).
Open Vibrator Controller
Statistics views > Numeric view
698 428XL Users Manual Vol. 1
April 11, 2013
14
Index
428XL Users Manual Vol. 1 699
April 11, 2013
ABCDE F GHI J K L MNOP QRS T UVWXY Z
Index
428XL manuals
IM =Installation Manual
U1 =Users Manual Vol. 1
U2 =Users Manual Vol. 2
U3 =Users Manual Vol. 3
TM =Technical Manual
Numerics
3592 cartridge drive IM: 225
3C
polarity, SEGD U3: 277
408ULS
Handling IM: 356
428-Lite
connectors IM: 509
installing IM: 66
installing, operating system IM: 126
A
Abort
button, Operation U1: 250
Plot U1: 594
TMS428 tests TM: 56
Absolute
spread U1: 144
Spread, tests U1: 215
Accelerated
weight drop U1: 71
Acceleration
baseplate, monitoring, VE432 U1: 640
mass, monitoring, VE432 U1: 640
Acceptance
tests U3: 263
Account IM: 174
Acquisition
Error description (SEGD) U2: 28
graphic view, normal, OVC U1: 690
graphic view, normal, VE432 U1: 671
graphic view, normal, VE464 U1: 557
index, process type U1: 257
Length U3: 289
Length (SEGD) U2: 25
local, VE432 U1: 655
local, VE464 U1: 550
Nb, APS U2: 162
normal, OVC U1: 690
normal, VE432 U1: 670
normal, VE464 U1: 556
Number (SEGD) U2: 28
numeric view, normal, OVC U1: 692
numeric view, normal, VE432 U1: 674
numeric view, normal, VE464 U1: 560
test, TMS428 TM: 108
type, OVC U1: 686
type, Process type U1: 257
type, VE432 U1: 635
type, VE464 U1: 516
Acquisition type tables (SEGD) U2: 27
Action (see Shortcuts)
Active
swath U1: 97
Activity
window U1: 98
ADC
test, TMS428) TM: 104
Add
button U1: 31
to query U1: 452
to quick launch, TMS428 TM: 62
Additional
blocks (SEGD general header) U2: 19
effects U1: 447
Address
Index
700 428XL Users Manual Vol. 1
April 11, 2013
ABCDE F GHI J K L MNOP QRS T UVWXY Z
428XL local network IM: 46
Client computer IM: 183
FUJ I 3x90, changing IM: 215
FUJ I 3x90, displaying IM: 216
Intranet IM: 98, IM: 99, IM: 106,
IM: 114, IM: 115, IM: 122,
IM: 123, IM: 129, IM: 136,
IM: 163, IM: 169
LCI-428, changing IM: 49
LCI-428, selecting U1: 66
LTO, changing IM: 221
MAC U1: 71
TMS428 TM: 46
Adjusting
clock, LCI TM: 20
Administration
server U1: 42
Advance II U3: 100
Advanced
connection parameters U1: 38
mode, LT428 IM: 379, IM: 390,
IM: 392
process type U1: 255
Again
Plot U1: 594
AGC
plotter U1: 604
Air
gun (SPS) U2: 78, U2: 126
pressure psi (SPS) U2: 92, U2: 142
Alarm
Positioning U1: 442
Alert
system U1: 442
Alias filter
Frequency at - 3dB point (SEGD)
U2: 24
Slope (SEGD) U2: 24
Angle from skew (SPS) U2: 74, U2: 86,
U2: 122, U2: 136
Annotation
logging U1: 89
Antenna
Height, format U2: 166
Append
VE432 vib (Look) U1: 653
Apply
All, Survey setup U1: 125
button U1: 32
Sensor, Survey setup U1: 125
APS
File format U2: 159
report U1: 587
Archiving
configuring U1: 72
DSUT TM: 171
system status U1: 58
Array
Forming (SEGD) U2: 24
Arrays, sub, number of U2: 92, U2: 142
Assembly
Location (SEGD) U2: 39
Serial number (SEGD) U2: 39
Type (SEGD) U2: 39
Authorization
granting U1: 43
Auto
Corr Peak Time U1: 260
Export U1: 460
Level, VE432 vib drive U1: 666
Level, VE464 vib drive U1: 544
Lift, VE432 U1: 637
Lift, VE464 U1: 518
Look U1: 149
noise editing U1: 300
saving TMS428 reports TM: 62
Auto/Manual
noise editing threshold U1: 300
VE432 U1: 650
VE464 U1: 534
Autocorrelation peak time (SEGD)
U2: 28
Automatic
Saving, DSUT TM: 161
Automation
Continuous, shooting U1: 281
Discontinuous, shooting U1: 281
Look U1: 285
Manual, shooting U1: 282
shooting U1: 280
Index
428XL Users Manual Vol. 1 701
April 11, 2013
ABCDE F GHI J K L MNOP QRS T UVWXY Z
Autonomous
mode, enabling U1: 280
mode, using U1: 371
Aux
Channel contents (SPS) U2: 75,
U2: 88, U2: 123, U2: 138
Line U1: 137
Process Descriptor U1: 261
Traces, number of U2: 25
Auxiliary
channel, description U1: 137
channels U1: 137
channels, Comments U1: 139
channels, deploying IM: 344
channels, Gain U1: 138
channels, Instrument tests U1: 216
trace scaling U1: 606
trace, description U1: 261
Average
distortion, APS U2: 160
force, APS U2: 160
ground stiffness, APS U2: 160
ground viscosity, APS U2: 160
phase, APS U2: 160
AWD U1: 71
B
Backup
GoBook Q200 IM: 311
setup U1: 93
Backward
playback U1: 472
Banner
setup, plotter U1: 595
Base
Tracs TDMA U1: 522
Base scan interval (SEGD) U2: 20
Baseplate
acceleration, monitoring, VE432
U1: 640
velocity, monitoring, VE432 U1: 640
Basic
pilot signal, VE432 (Acquisition type)
U1: 636
sweep signal, VE432 (Acquisition type)
U1: 636
sweep signal, VE464 (Acquisition type)
U1: 517
Basic Type
LOG, dB/Hz, VE432 U1: 622
LOG, dB/Hz, VE464 U1: 502
LOG, dB/octave, VE432 U1: 625
LOG, dB/octave, VE464 U1: 505
Setup, VE432 U1: 619
Setup, VE464 U1: 499
Taper, VE432 U1: 619
Taper, VE464 U1: 500
Tn, VE432 U1: 626
Tn, VE464 U1: 506
Batteries (Show/hide) U1: 113
Battery
GoBook Q200 IM: 307
LED TM: 101
Limit, LT428 IM: 381
polarity test (TMS428) TM: 102
test TM: 102
voltage limit U1: 113
Baud
rate, Raveon radio (VE464) U1: 525
rate, Tracs TDMA U1: 522
Bearing
source line, VE432 U1: 648
source line, VE464 U1: 532
Beginner U1: 50
Blaster
Advance II U3: 100
connector, LCI-428 IM: 504, IM: 505
controller, in line IM: 360
controllers U1: 303
id (SEGD) U2: 26
MACHA U3: 107
SGDS U3: 108
Shallow Sequencer U3: 105
Shot Pro U3: 101
signals IM: 506
status (SEGD) U2: 26
type U1: 70
Blasters
interfacing U3: 97
Blocking
trace U1: 465
Index
702 428XL Users Manual Vol. 1
April 11, 2013
ABCDE F GHI J K L MNOP QRS T UVWXY Z
Blocks in General Trailer U2: 21
BoomBox U1: 70
wiring IM: 521
Box
type, detour U1: 141
Break
Point U1: 274
Bridge
radio, ethernet IM: 483
Browser
settings U1: 40
Buffer U1: 66
Build
feature query U1: 451
Built-in
LAUX, upgrading TM: 118
Button U1: 24
Bypass
file exports U1: 461
Bytes per scan (SEGD) U2: 19
C
Cable
BoomBox IM: 521
calibration TM: 57
length, Line IM: 340, IM: 341
Line cable length IM: 340, IM: 341
Macha IM: 520
path U1: 119
replacing, LAUL TM: 224
SGD-S Blaster IM: 517
ShotPro IM: 518, IM: 519
tester TM: 195
Cables IM: 503
Calibration
clock, LCI TM: 20
DSUT TM: 130
FDU U3: 127, TM: 94
meter and test cables TM: 57
multimeter, TMS428 TM: 34
TMU428 TM: 121
Camp
distance to, alarm U1: 445
Capacitance
error (SEGD) U2: 38
high limit (SEGD) U2: 38
low limit (SEGD) U2: 38
value (SEGD) U2: 38
Capacity
Processing U3: 287
Cartridge
insertion U1: 490
Cartridge drive
Shock-mount parts IM: 213
Cartridge drive. See Tape drive
CDU
configuration IM: 85
Centre
button (mouse) U1: 115
Change
button U1: 31
Changing
LCI-428 U1: 64
Serial number (TMS428) TM: 116
Channel
auxiliary, description U1: 137
data error overscaling (SEGD) U2: 41
edited status (SEGD) U2: 42
filter (SEGD) U2: 41
filter response U3: 55
gain control method (SEGD) U2: 23
gain scale (SEGD) U2: 41
increment (SPS) U2: 80, U2: 97,
U2: 129, U2: 147
number (SEGD) U2: 39
process (SEGD) U2: 42
Raveon radio U1: 525
sample to mV conversion factor
(SEGD) U2: 42
Set End Time (SEGD) U2: 23
Set Number (SEGD) U2: 33
set number (SEGD) U2: 23
Set Starting Time (SEGD) U2: 23
set, number of channels in U2: 23
sets per record U1: 91, U2: 20
skipping U1: 153
Tracs TDMA U1: 522
type (SEGD) U2: 40
type id (SEGD) U2: 42
Type Identification (SEGD) U2: 23
Index
428XL Users Manual Vol. 1 703
April 11, 2013
ABCDE F GHI J K L MNOP QRS T UVWXY Z
type, Log shooting setup U1: 576
Channels, number of (SPS) U2: 75,
U2: 87, U2: 123, U2: 137
Charge
Depth U2: 91, U2: 141
Length U2: 91, U2: 141
Chat U1: 62
Check
Line U1: 224
Checkerboard
view U1: 118
Circular bearing of H256 (SPS) U2: 74,
U2: 85, U2: 122, U2: 136
Cleaning
boxes IM: 316
plugs IM: 316, TM: 293
Click U1: 24
right, Line window U1: 117
Client
installing IM: 159
main window U1: 50
SPS U2: 73, U2: 83, U2: 121,
U2: 133
Clipping
method (noise elimination) U1: 387
noise editing type U1: 298
plotter U1: 609
Clock
internal U1: 88
LCI TM: 20
time w.r.t. GMT (SPS) U2: 73, U2: 83,
U2: 121, U2: 134
Cluster U1: 292
CMRR
geophone string U3: 242
Instrument (TMS428) TM: 93
Instrument test U1: 218
test record result recovery U3: 123
test, FDU U3: 180
test, Field (TMS428) TM: 89
test, Sensor U3: 202
CN3e IM: 290
Getting started IM: 371
installing LT428 software IM: 296
network address IM: 284
resetting IM: 292
Code
Producer U1: 91
COG
Easting, format U2: 166
elevation, format U2: 166
file, format U2: 166
log file U1: 587
Northing, format U2: 166
radius threshold U1: 412
source position (estimated) U1: 435
status, format U2: 166
to source deviation, format U2: 166
Comments
Auxiliary channels U1: 139
LT428 results IM: 400
observer, setup U1: 302
SEGD U2: 31
setup, Operation window U1: 276
Common
Mode Rejection U1: 218
mode, Field (TMS428) TM: 89
mode, Instrument (TMS428) TM: 93
mode, test network, FDU calibration
U3: 150
Common mode
rejection ratio, geophones U3: 242
Communications
protocol, source controllers U3: 97
Compound
basic sweep signal, VE432 U1: 632
basic sweep signal, VE464 U1: 513
Computation Domain, APS U2: 163
Connecting
FDU link, TMS428 TM: 70
FDU2S, TMS428 TM: 71
LAUL, TMS428 TM: 72
LAULS, TMS428 TM: 73
LAUX, TMS428 TM: 74
LAUXS, TMS428 TM: 80
LAUXS-428, TMS428 TM: 78
LT428 IM: 370
TMS428 device under test TM: 69
Connection
crew Web site U1: 59
Index
704 428XL Users Manual Vol. 1
April 11, 2013
ABCDE F GHI J K L MNOP QRS T UVWXY Z
opening a session U1: 38
Connector (see Replacing)
Connectors IM: 503
428-Lite Break-Out Box IM: 509
Blaster1 IM: 504
Blaster2 IM: 505
FDU Input IM: 511
FDU2S takeoutt IM: 515
LAUL
XDEV IM: 509, IM: 512
LAUL-428 IM: 512
LAUX
LINE IM: 513
Power IM: 513
TRANSVERSE IM: 513
XDEV IM: 514
Consumption
port, TMS428 TM: 105
Continuity
test limit U1: 130
Continuous
shooting U1: 281
Control
type (SPS) U2: 77, U2: 91, U2: 125,
U2: 141
unit serial number (SEGD) U2: 41
unit type (SEGD) U2: 41
Controller
source, time management U1: 89
Conversion
sample to mV U2: 42
Converting
coordinates U1: 453
samples to mV U3: 235
Coord. status final/prov (SPS) U2: 78,
U2: 92, U2: 126, U2: 142
Coordinate location (SPS) U2: 73,
U2: 83, U2: 121, U2: 133
Coordinates
converting U1: 453
Copy
and Paste U1: 34
function (Export window) U1: 473
tape, file U3: 16
Copy+software tool U3: 21
Copying
files to tape U1: 484
CopyMedia U3: 16
Copyrights U1: 83
Correction
factor, FDU calibration U3: 128,
TM: 94
rate, DGPS (Raveon) U1: 525
rate, DGPS (Tracs TDMA) U1: 521
Correlation
After Stack, process type U1: 268
After stack, theory of U1: 389,
U1: 391
Before Stack, process type U1: 266
data distribution U1: 396
Frequency domain U3: 232
more about U1: 394
pilot, choosing U1: 258
Time domain U3: 232
Correlator, noise supp (SPS) U2: 77,
U2: 91, U2: 125, U2: 141
Corrosion IM: 357
CRC errors U3: 249
Create
selection U1: 452
Crew
name U1: 86
name, Comment (SPS) U2: 75,
U2: 87, U2: 123, U2: 137
number, VE432 U1: 616
number, VE464 U1: 496
setup U1: 86
VE464 vibrators U1: 496
vibrators, OVC U1: 685
vibrators, VE432 U1: 616
Crossline
spacing, AGC U1: 606
Crosstalk
Instrument test U1: 217
Instrument, FDU U3: 183
test record result recovery U3: 124
Crosstalk test
DSU3 U3: 218, U3: 228
CT400 TM: 195
Custom
Index
428XL Users Manual Vol. 1 705
April 11, 2013
ABCDE F GHI J K L MNOP QRS T UVWXY Z
basic sweep signal, VE432 U1: 629
basic sweep signal, VE464 U1: 508
sweep file, VE432 (how to load)
U1: 631
sweep, loading to VE464 DPG U1: 546
Customer
support U1: 83
Customizing
TMS428 tests TM: 81
Cut off
error (SEGD) U2: 38
high limits (SEGD) U2: 38
low limit (SEGD) U2: 38
value (SEGD) U2: 38
Cygwin IM: 191
D
DAC
Common-Mode resistance, FDU
calibration U3: 150
line current correction, FDU calibration
U3: 141
rough current correction, FDU
calibration U3: 135
Damp coeff, natural freq. (SPS) U2: 76,
U2: 124
Damping coeff, natural freq (SPS)
U2: 89, U2: 139
Data
archive, DSUT TM: 171
Bypass U1: 461
computation domain, VE432 vib QC
U1: 643
computation domain, VE464 vib QC
U1: 528
record sorting order (SPS) U2: 70,
U2: 118
Data rate
Line U3: 287
Transverse U3: 287
Date
of survey (SPS) U2: 73, U2: 82,
U2: 121, U2: 132
SEGD U2: 28
Datum U1: 454
type, setup U1: 406
Datum Type setup
Datum U1: 454
Ellipsoid U1: 454
Geoid U1: 454
Day
of year (SPS) U2: 79, U2: 95,
U2: 127, U2: 145
of Year, APS U2: 163
Dead seis traces, number of U2: 25
Deboost
basic sweep signal, VE432 U1: 633
basic sweep signal, VE464 U1: 514
Default
Channel type, Log U1: 576
Delay
at end of Acq. U1: 293
at end of VP U1: 293
basic sweep signal, VE432 U1: 633
basic sweep signal, VE464 U1: 512
lift up, VE432 U1: 667
lift up, VE464 U1: 545
no-move alarm U1: 445
radio, measuring, VE432 U1: 662
radio, VE432 U1: 660
refraction, process type U1: 256
setup, Operation window U1: 293
speed alarm U1: 446
Delete
button U1: 32
Deploying
field equipment IM: 313
Depth
charge U2: 91, U2: 141
towing U2: 92, U2: 142
Descale Multiplier (SEGD) U2: 23
Description
absolute spread U1: 144
Auxiliary channels U1: 137
Channels (Aux), Instrument tests
U1: 216
Channels (tests) U1: 215
Generic Line U1: 147
Generic spread U1: 148
Index
706 428XL Users Manual Vol. 1
April 11, 2013
ABCDE F GHI J K L MNOP QRS T UVWXY Z
of grid units (SPS) U2: 73, U2: 84,
U2: 121, U2: 135
of survey area (SPS) U2: 73, U2: 82,
U2: 121, U2: 132
Receiver section U1: 127
Survey U1: 126
Desensitization IM: 421, U1: 203
Desktop U1: 41
Detect
end of tape U1: 490
Detection
fiber, TMS428 TM: 106
Detour U1: 139
skipped receiver points U1: 157
Deviation, COG to source, format
U2: 166
Dialog box U1: 24
Digital
pilot, additional U1: 518
pilot, choosing U1: 517
pilot, correlation U1: 258
Sensor Unit, deploying IM: 322
Directories
DSUT TM: 143
Disable
radio U1: 211
Disassembling
DSU TM: 214
FDU TM: 209
FDU2S TM: 268
LAUL TM: 225
LAULS TM: 272
LAUR TM: 249
LAUX-428 TM: 231
LAUX-G TM: 237
LAUXS TM: 243, TM: 278
LRU TM: 257
TFOI TM: 364
TFOI-G TM: 353
TREP-428 TM: 264
Discharge
ESD protection TM: 18
Discontinuous
shooting U1: 281
Disk
buffer U1: 66
record, setup U1: 93
space, monitoring U1: 491
Disk space
DSUT TM: 143
Display
mode, LT428 IM: 398
Traces per inch U1: 609
Distance
no-move alarm U1: 445
simultaneous sources U1: 283
Distortion
Instrument test U1: 217
Sensor test U3: 207
test record result recovery U3: 116
test, FDU U3: 177
test, TMS428 TM: 93
Distortion test
DSU U3: 217, U3: 227
Distortion, APS U2: 160
Diversity
enhanced (theory of) U1: 391
stack U1: 296
stack (theory of) U1: 389
Dongle IM: 197, U1: 67
Double-click U1: 24
Download
DSUGPS firmware U1: 169
from crew Web site U1: 60
setup (firmware) U1: 235
DPG
number of U1: 70
Slave, VE432 U1: 617
Slave, VE464 U1: 497
status code, VE464 U1: 562
DPG Hosd Id U1: 67
Drag U1: 24
Drag and drop
base camp U1: 426
recording unit U1: 426
source (Positioning) U1: 428
Drilling
tool, DSU-428 IM: 325
Drive
level, APS U2: 160
Index
428XL Users Manual Vol. 1 707
April 11, 2013
ABCDE F GHI J K L MNOP QRS T UVWXY Z
level, high, VE432 U1: 666
level, high, VE464 U1: 545
level, low, VE432 U1: 666
level, low, VE464 U1: 545
tape, install U1: 72
transfer to U3: 287
Drive. See Tape drive
Driver
graphic, Linux IM: 202
DSD
Get, VE432 U1: 657
Get, VE464 U1: 541
Network, Navigation U1: 306
network, VE432 U1: 617
network, VE464 U1: 498
reference signal, VE432 U1: 640
setting, OVC U1: 690
setting, VE432 U1: 656
setting, VE464 U1: 539
status code, VE464 U1: 562
VE432 status, get U1: 639
VE464 status, get U1: 529
DSP
DRAM & DPR test TM: 100
DSU
Deploying IM: 322
disassembly instructions TM: 214
Re-assembly instructions TM: 217
tests TM: 177
DSU1-428
test specifications U3: 298
DSU3
theory of tests U3: 211
tilt correction U1: 177
trace correction formula U3: 261
DSU3-428
in Line window U1: 160
test specifications U3: 298
tester (DSUT428) TM: 127
DSU3BV-428
deploying IM: 329
specifications U3: 284
DSUGPS
acquisition U1: 162
deploying IM: 328
firmware upgrading U1: 169
GPS Base Position station IM: 60
in Line window U1: 160
in Positioning window U1: 430
Instrument view U1: 173
instrument view U1: 173
Setup menu U1: 167
specifications U3: 284
SPS positions U1: 584
DSUT
Archiving TM: 171
Getting started TM: 146
Installation, hardware TM: 131
installation, software TM: 136
Log-in TM: 146
password TM: 146
Repair assistant TM: 164, TM: 166
Repair log file TM: 166
Running tests TM: 156
Specifications TM: 128
Statistics TM: 169
Test report TM: 172
Test sequence editor TM: 154
Dump
Output button U1: 258
to SQC U1: 280
Dump stacking fold (SEGD) U2: 28
Duplicating, tape, file U3: 16
Duplication, sample U3: 249
DXF format U1: 421
Dynamic
grouping, fleets U1: 284
E
e428 software
licence U1: 67
Earth
ground resistor, FDU calibration
U3: 156
Easting, COG, format U2: 166
Edit menu
DSUT TM: 154
Editing
Noise U1: 296
number of windows (noise) U1: 298
Index
708 428XL Users Manual Vol. 1
April 11, 2013
ABCDE F GHI J K L MNOP QRS T UVWXY Z
Spike U1: 386
system parameters (Log) U1: 574
type (noise) U1: 298
Zeroing Length (noise) U1: 298
Zeroing Taper Length (noise) U1: 298
Effect
speed alert U1: 447
Electrostatic
discharge TM: 18
Elevation
antenna height, format U2: 166
COG, format U2: 166
reference U1: 410
Ellipsoid U1: 454
Ellipsoidal
model U1: 410
Emergency
alarm U1: 442
Enable
instruments U1: 66
radio U1: 211
Enabled
export U1: 452
End
colour map scale U1: 449
line plug IM: 339
of media U1: 469
of tape, detecting U1: 490
End-of-line plug IM: 339
EOF U1: 468
EOM U1: 469
Error
leakage U1: 151
only, TMS428 report TM: 63
recovery, Micro-seismic U1: 370
Errors
CRC U3: 249
DSUT TM: 181
ESD TM: 18
eSQC Pro IM: 33
Esri format U1: 421
Estimated
source COG U1: 435
Ethernet
port, identifying IM: 50
port, testing (TMS428) TM: 110
radio bridge IM: 483
Event
log viewer U1: 589
Excitation Overload, APS U2: 163
Expanded file number (SEGD) U2: 21,
U2: 22
Explosive
source type setup U1: 288
Explosive (SPS) U2: 78, U2: 126
Exponent, subscans U2: 23
Exponential
basic sweep signal, VE432 U1: 626
basic sweep signal, VE464 U1: 506
time, plotter U1: 605
Export
Auto/Manual U1: 460
client window U1: 455
enabled U1: 452
mode U1: 72
Exporting
LT428 results IM: 401
SPS files U1: 583
to NAS U1: 479
Exports
configuring U1: 72
Extended
channel set number (SEGD) U2: 24,
U2: 33
Channel Sets/Scan Types (SEGD)
U2: 21
file number (SEGD) U2: 33
header (SEGD) U2: 25
header blocks (SEGD) U2: 21
header flag (SEGD) U2: 24
header length (SEGD) U2: 20
QC, VE432 vib U1: 643
QC, VE464 vib U1: 529
receiver line number (SEGD) U2: 34
receiver point number (SEGD) U2: 35
Record Length (SEGD) U2: 21
Extender
TFOI, connecting IM: 336
External
header (SEGD) U2: 31
Index
428XL Users Manual Vol. 1 709
April 11, 2013
ABCDE F GHI J K L MNOP QRS T UVWXY Z
header blocks (SEGD) U2: 21
header length (SEGD) U2: 20
label U1: 464
tape label U1: 92
F
Factor to metre (SPS) U2: 73, U2: 85,
U2: 121, U2: 135
Farthest
Rcv Nb, LT428 IM: 388
FDPA428
connecting IM: 441
operating guide IM: 443
FDU
Calibration U3: 127
connector, replacing TM: 284
disassembly instructions TM: 209
INPUT connector IM: 511
Input polarity IM: 511
Max number between LAUs IM: 341,
IM: 342
Number in link, LT428 IM: 407
Number in link, TMS428 TM: 122
Power supply IM: 340
reassembly instructions TM: 210
unit type (SEGD) U2: 39
FDU2S
Disassembly instructions TM: 268
Input polarity IM: 515
Re-assembly instructions TM: 269
Takeout connector IM: 515
FDU-428
deploying IM: 317
test specifications U3: 296
Feature
property names U1: 449
Fiber
detection, TMS428 TM: 106
Fibre Optics
allowable loss TM: 342
connector, replacing TM: 392
repairs TM: 341
splices, number of TM: 342
TFOI, connecting IM: 336
Field
computer system(s) (SPS) U2: 73,
U2: 83, U2: 121, U2: 133
electronics, upgrading U1: 235
electronics, upgrading via XDEV
IM: 152
on/off U1: 107
record increment (SPS) U2: 80,
U2: 97, U2: 129, U2: 147
record number (SPS) U2: 80, U2: 97,
U2: 129, U2: 147
tape number (SPS) U2: 80, U2: 97,
U2: 129, U2: 147
test limits, LT428 IM: 382
test, automation U1: 285
test, LT428 IM: 392
update U1: 149
update mode U1: 103, U1: 219,
U1: 220
Field Units (see Instruments)
File
count (SEGD) U2: 28
duplicating U3: 16
Header block (SEGD) U2: 19
Load/Save U1: 593
menu (TMS428) TM: 55
number (SEGD) U2: 19, U2: 33
number, recording U1: 96
packager U1: 58
Files
per tape U1: 465
per tape (SEGD) U2: 28
Filter
alias Hz, dB pnt, slope (SPS) U2: 75,
U2: 87, U2: 123, U2: 137
low Hz, dB pnt, slope (SPS) U2: 75,
U2: 88, U2: 123, U2: 138
LT428 IM: 379
notch Hz, -3 dB points (SPS) U2: 75,
U2: 123
notch Hz, -3dB points (SPS) U2: 88,
U2: 138
playback U3: 43
response, channel U3: 55
servo control, VE432 U1: 665
servo control, VE464 U1: 544
type U1: 87
Index
710 428XL Users Manual Vol. 1
April 11, 2013
ABCDE F GHI J K L MNOP QRS T UVWXY Z
type (SEGD) U2: 28
Filters
plotter U1: 607
Firing
Order (FO), process type U1: 255
Firmware
updating U1: 235
updating, TMS428 TM: 56
updating, via XDEV IM: 152
upgrading (TMS428) TM: 112
version, reading (TMS428) TM: 111
First
Notch Frequency (SEGD) U2: 24
Timing Word (SEGD) U2: 33
waypoint U1: 415
Fleet
cluster U1: 325
group, dynamic U1: 284
Ready U1: 291
VE464 vibrator, crew U1: 497
vibrator, APS format U2: 160
vibrator, VE432 crew U1: 617
Floppy disk
specifications (SPS) U2: 70, U2: 71,
U2: 118, U2: 119
FM4 plug assembly
SRHRF cable TM: 309
ST+cable TM: 298
WPSR cable TM: 322
FO Window
VE432 U1: 645
Folders
DSUT TM: 143
Force
ground, monitoring, VE432 U1: 640
Overload, APS U2: 163
Force, APS U2: 160
Form
Line, LT428 IM: 387
Transverse, LT428 IM: 395
Format
APS U2: 159
code (SEGD) U2: 19
instrument test limit U2: 53
SEGD U2: 15
SEGD, Rev 2.1 U2: 45
Source
controllers U3: 97
SPS, initial U2: 65
SPS, Rev. 2.1 U2: 111
SPS-like U2: 159
synthetic file U2: 57
version num. (SPS) U2: 73, U2: 82,
U2: 121, U2: 132
Forward
playback U1: 472
Fourier
Transform U3: 232
Frequency
domain U3: 232
LRU IM: 418, U1: 199
Nyquist U1: 87
From channel (SPS) U2: 80, U2: 97,
U2: 129, U2: 147
From receiver (SPS) U2: 80, U2: 98,
U2: 129, U2: 148
FTP
exporting U1: 459
server U1: 72
server setup U1: 467
server, installing on PC IM: 271
FUJ I 3x90
address, changing IM: 215
address, displaying IM: 216
Functions
Test U1: 213
VE432 U1: 650
VE464 U1: 534
G
Gain
Auxiliary channels U1: 138
code U1: 145
code, absolute spread U1: 144
error, Instrument test U1: 218
geophone string U3: 241
Instrument tests U1: 216
LT428 IM: 379
Preamplifier, 0 dB, FDU calibration
U3: 131
Index
428XL Users Manual Vol. 1 711
April 11, 2013
ABCDE F GHI J K L MNOP QRS T UVWXY Z
Preamplifier, 12 dB, FDU calibration
U3: 160
Seismonitor U1: 114
shooting setup, Log U1: 576
test record result recovery U3: 117
test, FDU U3: 173
test, TMS428 TM: 93
Gain test
DSU U3: 216, U3: 226
Gap U1: 127
between receiver sections U1: 134
General
Header block 1 (SEGD) U2: 19
Header block 2 (SEGD) U2: 21
Header block 3 (SEGD) U2: 22
Header Block Number (SEGD) U2: 21,
U2: 22
LT428 parameters IM: 375, IM: 379
Trailer blocks, number of U2: 21
Generate
report U1: 452
Generic
spread U1: 146
spread, description U1: 148
Geodetic datum
parameters (SPS) U2: 73, U2: 84,
U2: 121, U2: 134
spheroid (SPS) U2: 73, U2: 84,
U2: 121, U2: 134
Geographic
AGC U1: 605
Geographic (see Topographic)
Geoid U1: 454
Geoidal
model U1: 410
Geophone
arrangement U3: 243
number per trace U3: 240
parallel U3: 241
series U3: 241
strings U3: 240
Geophysical contractor (SPS) U2: 73,
U2: 83, U2: 121, U2: 133
Geotiff format U1: 421
Geozone
alarm U1: 443
Get
Similarities, VE464 U1: 553
VE432 DSD U1: 657
VE432 DSD status U1: 639
VE464 DSD U1: 541
VE464 DSD status U1: 529
Getting started
428XL GUI U1: 37
DSUT TM: 146
FDPA428 IM: 443
LT428 IM: 371
TMS428 TM: 49
Giga Transverse IM: 37
DSU IM: 324
GIS U1: 448
Global
rendering, plotter U1: 609
Go
starting a shot U1: 249
to waypoint U1: 377
Topographic view U1: 109, U1: 111
GoBook IM: 305
connecting IM: 370
Getting started IM: 371
Q200 IM: 369
GoBook Q200
Backup IM: 311
Battery IM: 307
installing IM: 308
quick guide IM: 305
Reinstalling IM: 312
resetting IM: 306
GPS
differential corrections, Raveon radio
U1: 524
differential corrections, Tracs TDMA
U1: 521
time management U1: 89
Grabbing
VP U1: 412
Graphic
driver, Linux IM: 202
view, normal acquisition, OVC
U1: 690
Index
712 428XL Users Manual Vol. 1
April 11, 2013
ABCDE F GHI J K L MNOP QRS T UVWXY Z
view, normal acquisition, VE432
U1: 671
view, normal acquisition, VE464
U1: 557
view, Positioning window U1: 416
Graphic view (see Topographic)
Graphics
how to select U1: 34
Gravity
test U1: 218
Gravity test, DSU U3: 224
Grid
coord. at origin (SPS) U2: 74, U2: 85,
U2: 122, U2: 135
origin (SPS) U2: 74, U2: 85, U2: 122,
U2: 135
Ground
earth resistor, FDU calibration U3: 156
force, monitoring, VE432 U1: 640
stiffness, APS U2: 160
TMS428 TM: 35
viscosity, APS U2: 160
wing nut, replacing TM: 284
Group
geophone string U3: 245
Guest
privileges U1: 44
Guidance
overview U1: 376
set, VE464 U1: 552
vibrator, enabling U1: 284
H
Hardware
installing IM: 45
HDOP, APS U2: 163
Header
external, size U1: 91
Header record
description (SPS) U2: 82, U2: 132
specification (SPS) U2: 72, U2: 120
Height
antenna, format U2: 166
Help TM: 59
language U1: 40
send, emergeny alarm U1: 443
Hide
layer (Positioning) U1: 420
High
box, detour U1: 141
channel, detour U1: 141
Line, sync, VE432 U1: 637
Line, sync, VE464 U1: 518
SN, detour U1: 141
VE432 drive level U1: 666
VE464 drive level U1: 545
High-cut
filter, plotter U1: 607
playback filter U3: 44
Hilbert
transform, VE432 U1: 631
Histogram
view U1: 123
Historic
editing type (SEGD) U2: 27
range (SEGD) U2: 27
taper length (SEGD) U2: 27
threshold Init value (SEGD) U2: 27
zeroing length (SEGD) U2: 27
Historical
Noise Editing U1: 296
History
Line window U1: 122
Hold/Var U1: 300
Hot
Line U1: 83
Hour of day (SEGD) U2: 19
I
Icon U1: 25
ID
VE464 vibrator U1: 497
vibrator, VE432 U1: 617
Identity
card U1: 84
Identity Card U1: 59
Immersible
electronics IM: 350
Index
428XL Users Manual Vol. 1 713
April 11, 2013
ABCDE F GHI J K L MNOP QRS T UVWXY Z
Impedance
geophone string U3: 241
Importing
SPS files U1: 581
Impulse
Sensor test U3: 205
Impulsive
process type U1: 264
Stack process type U1: 265
Inactive
units (detour) U1: 139
Increment
LT428 Rcv num IM: 378
Marker U1: 136
Shot U1: 288
VP to do U1: 290
Index
box U1: 25
Source Point U1: 244
Indicator
replacing TM: 290
Init
Thresh U1: 300
Initialization, DSUT hardware TM: 147
Inline
spacing, AGC U1: 606
Input
resistance, FDU calibration U3: 135
servo control loop, VE432 U1: 665
servo control loop, VE464 U1: 544
Inserting
cartridge U1: 490
Install
window U1: 64
Installing
428-Lite IM: 66
Client software IM: 159, IM: 179
DSUT hardware TM: 131
DSUT software TM: 136
Ethernet plotter IM: 207
FDPA428, GoBook IM: 308
FTP server on PC IM: 271
Handheld PC software IM: 279
hardware IM: 45
laser link IM: 469
LT428 software, CN3e IM: 296
LT428, GoBook IM: 308
patch (client) IM: 187
patch (server) IM: 148
Redhat, client IM: 161
Redhat, server IM: 94, IM: 110
server software IM: 140
TMS428 hardware TM: 35
TMS428 software TM: 37
TMS428 software new release TM: 40
Vehicle tracking box IM: 278
Instrument
Code (I) tables (SPS) U2: 75, U2: 123
Code (SPS) U2: 80, U2: 97, U2: 129,
U2: 147
Crosstalk U1: 217
FDU U3: 183
Distortion U1: 217
Gain error U1: 218
Noise U1: 217
Phase error U1: 218
Pulse test U1: 218
test limits U2: 53
test limits, LT428 IM: 383
test record recovery U3: 113
test specifications U3: 296
tests U1: 216
tests, CMRR (FDU) U3: 180
tests, Distortion (FDU) U3: 177
tests, FDU U3: 168
tests, Gain&Phase U3: 173
tests, LT428 IM: 391
tests, Noise U3: 170
tests, Offset U3: 172
tests, Pulse (FDU) U3: 186
tests, Resistance U3: 168
Instrument tests
Crosstalk
DSU3 U3: 218, U3: 228
Instruments
Colour U1: 111
Show/hide U1: 111
Interfacing
source controller U3: 97
Internal
ADC, testing (TMS428) TM: 104
Index
714 428XL Users Manual Vol. 1
April 11, 2013
ABCDE F GHI J K L MNOP QRS T UVWXY Z
clock U1: 88
time break (SEGD) U2: 27
Interpolation U1: 610
sample U3: 249
Intranet
address, configuring IM: 98, IM: 99,
IM: 106, IM: 114, IM: 115,
IM: 122, IM: 123, IM: 129,
IM: 136, IM: 163, IM: 169
IP address
428XL local network IM: 46
Client computer IM: 183
Intranet IM: 98, IM: 99, IM: 106,
IM: 114, IM: 115, IM: 122,
IM: 123, IM: 129, IM: 136,
IM: 163, IM: 169
LCI-428, changing IM: 49
TMS428 TM: 46
Irregular
LT428 layout IM: 390, IM: 392
J
jConfig window U1: 81
jExport window U1: 455
jInstall window U1: 63
jLine window U1: 101
jLog window U1: 567
jOperation window U1: 241
jOVC U1: 683
jPlotter window U1: 591
jPositioning window U1: 401
J ulian
day, backup setup U1: 94
J ulian day (SEGD) U2: 19
jVE432 window U1: 613
jVE464 window U1: 493
jVibOther window U1: 679
K
Kit
tools TM: 206
L
Lab
distance to, alarm U1: 445
Label
external U1: 464
properties U1: 448
tape, external U1: 92
Landscape
plotter U1: 608
Language
help U1: 40
Laser Link IM: 465
Installing IM: 469
Specifications IM: 481
Last
record, playback U1: 471
Lat. Long
initial line (SPS) U2: 74, U2: 85,
U2: 122, U2: 136
scale factor (SPS) U2: 74, U2: 85,
U2: 122, U2: 135
Lat. of standard parallel(s) (SPS) U2: 73,
U2: 85, U2: 121, U2: 135
Latitude
reference, vibrator guidance U1: 284
LAU tests
Transmission TM: 106
XILINX loading TM: 101
LAUL-428
cable replacement TM: 224
connectors IM: 509, IM: 512
deploying IM: 335
disassembly instructions TM: 225
Power supply IM: 340
reassembly instructions TM: 226
spacing IM: 340, IM: 341
LAULS
Disassembly instructions TM: 272
Re-assembly instructions TM: 274
Launch
quick, TMS428 tests TM: 62
Launcher
bar, customizing U1: 49
icons U1: 48
Index
428XL Users Manual Vol. 1 715
April 11, 2013
ABCDE F GHI J K L MNOP QRS T UVWXY Z
LAUR U1: 196
disassembly instructions TM: 249
reassembly instructions TM: 250
LAUR-428 IM: 412
LAUX
in TMS428 test system IM: 35
LAUX-428
connectors IM: 513, IM: 514
deploying IM: 335
disassembly instructions TM: 231
Power supply IM: 340
reassembly instructions TM: 232
LAUX-G IM: 37
disassembly instructions TM: 237
GPS receiver for DSUGPS IM: 324
reassembly instructions TM: 238
TFOI-G strain-relief TM: 400
LAUXS
Disassembly instructions TM: 278
Re-assembly instructions TM: 279
LAUXS-428
disassembly instructions TM: 243
reassembly instructions TM: 244
Layer
rename (Positioning) U1: 420
show/hide (Positioning) U1: 420
Layout
LT428 IM: 379
setup U1: 132
LCI
oscillator, adjusting TM: 20
LCI-428
address, selecting U1: 66
installing IM: 53
IP address, changing IM: 49
repairing TM: 21
replacing U1: 64
LCI-G IM: 37, IM: 324
installing IM: 52
Leak
testing TM: 292
Leakage
error U1: 151
error (SEGD) U2: 38
limit (SEGD) U2: 38
Line port, TMS428 TM: 105
Sensor test U1: 220
test U3: 197
Test circuitry (LAU) U1: 151
Test limit U1: 130
test, Field (TMS428) TM: 90
value (SEGD) U2: 38
LED
Run, testing (TMS428) TM: 103
LED test
DSU TM: 177
Length
pilot, other vibrator systems U1: 681
pilot, OVC U1: 686
record (SEGD) U2: 28
record, process type U1: 255
sweep, other vibrator systems U1: 680
sweep, OVC U1: 686
time, plotter U1: 610
Zeroing (noise) U1: 298
Zeroing Taper (noise) U1: 298
Level
alert, used disk space U1: 492
auto, VE432 vib drive U1: 666
auto, VE464 vib drive U1: 544
Licence
client IM: 197, U1: 67
information about U1: 46
LT428 IM: 371
Plotter IM: 198, U1: 68
VE464 Guidance IM: 199, U1: 69
Lift
up delay, VE432 U1: 667
up delay, VE464 U1: 545
Limit
instrument test U2: 53
Limits (see Test limits)
Line
check U1: 224
data rate U3: 287
end plug IM: 339
Error Recovery U1: 370
Generic U1: 147
mapping to a logical line U1: 155
name (SPS) U2: 79, U2: 80, U2: 93,
U2: 97, U2: 98, U2: 127,
Index
716 428XL Users Manual Vol. 1
April 11, 2013
ABCDE F GHI J K L MNOP QRS T UVWXY Z
U2: 129, U2: 143, U2: 147,
U2: 148
name, APS U2: 160, U2: 169
name, COG, format U2: 166
Nb Inc, LT428 IM: 378
number U1: 126
number format (SPS) U2: 74, U2: 86,
U2: 122, U2: 136
port, leakage test (TMS428) TM: 105
port, transmission test (TMS428)
TM: 107
power polarity (TMS428) TM: 110
sequence number, SPS U2: 121,
U2: 133
skipping U1: 148
socket, replacing TM: 285
splitting U1: 136
Test, LT428 IM: 376
troubleshooting U1: 225
LINE connector
LAUX IM: 513
Line Tester
operating guide IM: 367
Linear
basic sweep signal, VE432 U1: 621
basic sweep signal, VE464 U1: 501
Phase U1: 88
phase filter U3: 56
Link
FDU-428, examples IM: 320
Number of FDUs, update (LT428)
IM: 407
Number of FDUs, update (TMS428)
TM: 122
Linux
graphic driver IM: 202
List
box U1: 25
Listening
time U1: 256
Lite
connectors IM: 509
installing IM: 66
installing, operating system IM: 126
Live seis traces, number of U2: 25
LLX400. See Laser Link
LLX400. See Laser link
Load
Thresh U1: 300
Loading
Custom sweep (VE464 DPG) U1: 546
DSUT software TM: 136
system parameters U1: 575
TMS428 software TM: 37
Local
acquisition, VE432 U1: 655
acquisition, VE464 U1: 550
disk U1: 66
ellipsoidal model U1: 410
network IM: 39
oscillator, testing (TMS428) TM: 106
user U1: 39
LOG
dB/Hz, VE432 U1: 622
dB/Hz, VE464 U1: 502
dB/octave, VE432 U1: 625
dB/octave, VE464 U1: 505
Log
file, DSU repair TM: 166
files, compressing IM: 157
Log in
connecting to server U1: 38
DSUT TM: 146
installing server software IM: 141
name U1: 40
Logging
post-annotation U1: 89
Logging in
first time IM: 196
Logical
line mapping U1: 155
Login IM: 174
Long. of central meridian (SPS) U2: 74,
U2: 85, U2: 122, U2: 135
Look
Automatic U1: 285
automatic U1: 149
manual U1: 149
properties U1: 149
sensors U1: 109, U1: 111
Index
428XL Users Manual Vol. 1 717
April 11, 2013
ABCDE F GHI J K L MNOP QRS T UVWXY Z
test (TMS428) TM: 111
VE432 DSD U1: 651
Look&Feel U1: 41
Loop
LRU U1: 212
servo control, VE432 U1: 665
servo control, VE464 U1: 544
Loss
Fibre Optics repairs TM: 342
Low
box, detour U1: 141
channel, detour U1: 141
SN, detour U1: 141
stacks, number of U2: 42
Trace U1: 299
Trace Percentage (SEGD) U2: 27
Trace Value U1: 299
Trace Value (SEGD) U2: 27
VE432 drive level U1: 666
VE464 drive level U1: 545
Low-cut
Filter frequency (SEGD) U2: 24
Filter slope (SEGD) U2: 24
filter, plotter U1: 607
Playback filter U3: 44
LP traceability, DSU TM: 166
LRU IM: 412
Desensitization IM: 421, U1: 203
disassembly instructions TM: 257
Frequency IM: 418, U1: 199
Half-duplex IM: 417
reassembly instructions TM: 258
Sleep U1: 211
Time Division Multiplex U1: 204
LSI IM: 29, IM: 360
Instrument tests U1: 316
Shooting U1: 309
TB widow calibration U1: 310
LSS IM: 29
channel Instrument tests U1: 316
Instrument tests U1: 316
Shooting U1: 309
TB window calibration U1: 310
LT
Line Nb IM: 377
Position IM: 375, IM: 377
Rcv Nb IM: 378
Sensor Type Nb IM: 379
LT428
connecting IM: 370
Exec Line Test IM: 376
Exec Transverse Test IM: 376
Field test IM: 392
Getting started IM: 371
Instrument test IM: 391
main menu IM: 374
operating guide IM: 367
Power-on IM: 371
results IM: 398
running Line tests IM: 384
running Transverse tests IM: 394
Save Rcv Tilt model IM: 390
Self-test IM: 373
Set general parameters IM: 375,
IM: 379
Set LT position IM: 375, IM: 377
Set Test Limits IM: 375, IM: 381
Tap test IM: 376, IM: 404
LTO address, changing IM: 221
LXIU. See Laser link
LXIU-400. See Laser Link
M
MAC address U1: 71
MACHA U3: 107
Macha
wiring IM: 520
Macha blaster U1: 71
Maintenance
field electronics TM: 205
Field equipment TM: 20
TCXO on LCI board TM: 20
Management
sessions U1: 45
time U1: 88
Manual
Export U1: 460
Look U1: 149
noise editing U1: 300
scale, Line window U1: 123
Index
718 428XL Users Manual Vol. 1
April 11, 2013
ABCDE F GHI J K L MNOP QRS T UVWXY Z
shooting U1: 282
Manual/Auto
noise editing threshold U1: 300
VE432 U1: 650
VE464 U1: 534
Manufacturers
code (SEGD) U2: 19
serial nb (SEGD) U2: 19
Map grid
easting (SPS) U2: 79, U2: 94,
U2: 127, U2: 144
northing (SPS) U2: 79, U2: 94,
U2: 127, U2: 144
Mapping
line U1: 155
Marker
FDU2S channels U1: 182
increment U1: 136
Line Layout setup U1: 133
Marking, stop U1: 142
Mass
acceleration, monitoring, VE432
U1: 640
overload, APS U2: 163
velocity, monitoring, VE432 U1: 640
warning, APS U2: 162
Master
Ethernet radio bridge IM: 487
oscillator, LCI TM: 20
Master/slave
cabling IM: 64
operation U1: 382
Max
number of FDUs IM: 341, IM: 342
number of traces U3: 289
of max, Aux (SEGD) U2: 28
of max, Seis (SEGD) U2: 28
speed U1: 446
speed, scale U1: 414
MDR IM: 275
Media
copy U3: 16
Meter
calibration TM: 57
reset TM: 56
Micro-seismic
enabling U1: 280
usage U1: 369
Min
High Drive, VE432 U1: 667
High Drive, VE464 U1: 545
Low Drive, VE432 U1: 666
Low Drive, VE464 U1: 545
Minicom IM: 157
Minimum
Phase U1: 88
phase filter U3: 76
Minute of day (SEGD) U2: 19
Mode
display, plotter U1: 609
LT428 display IM: 379
operating U1: 279
Model
ellipsoidal U1: 410
geoidal U1: 410
Monitoring
disk space U1: 491
Monoline U1: 155
Mounting
parts IM: 70
Mouse
Buttons U1: 25
buttons U1: 25
Centre button U1: 115
Move
alarm U1: 445
MRU
configuring U1: 74
Multi-component
recording (SPS) U2: 75, U2: 88,
U2: 123, U2: 138
Multi-DPG configuration IM: 56
Multi-gun U1: 379
Multimeter
calibration, TMS428 TM: 34
Multimodule IM: 58
Multiple
tests U1: 222
Multi-screen IM: 203
Mute
Index
428XL Users Manual Vol. 1 719
April 11, 2013
ABCDE F GHI J K L MNOP QRS T UVWXY Z
channel U1: 142
N
Name
crew U1: 86
feature, colour map U1: 449
Log in U1: 40
plotter U1: 71
property, query builder U1: 451
user U1: 59
NAS IM: 33
archiving system U1: 73
exporting to U1: 479
Rescue mode IM: 244
NAS system IM: 231
connecting IM: 233
IP address on user network IM: 237
reinstalling IM: 241
shock-mount parts IM: 232
user network IM: 240
NAS4000
cabling IM: 252
shock-mount parts IM: 250
Navigation
option U1: 307
shooting mode U1: 306
Nb
Sensor/Rcv Pt, LT428 IM: 379
Network
DSD, Navigation U1: 306
VE432 DSD U1: 617
VE464 DSD U1: 498
Networking
428XL local network IM: 46
Client computer IM: 183
TMS428 TM: 46
Next
Plot U1: 594
record, playback U1: 472
NFS
disk setup U1: 466
server U1: 72
NFS disk
exporting to U1: 459
No
move U1: 445
reply U1: 444
No. sub arrays, nom depth (SPS) U2: 92,
U2: 142
Noise
Editing U1: 296
editing, setup U1: 295
elimination type (SEGD) U2: 27
Instrument test U1: 217
Sensor test U1: 220
Test limit U1: 130
test record result recovery U3: 115
test, FDU (Instrument) U3: 170
test, Field (TMS428) TM: 89
test, Instrument (TMS428) TM: 92
test, Sensor (FDU) U3: 191
Noise test
DSU U3: 215, U3: 225, TM: 178
Noisy
stacks, number of U2: 42
Trace % U1: 299
trace percentage (SEGD) U2: 27
Nominal towing depth U2: 92, U2: 142
Normal
acquisition OVC U1: 690
acquisition, VE432 U1: 670
acquisition, VE464 U1: 556
mode, LT428 display IM: 379
Normalization
plotter U1: 605
Northing, COG, format U2: 166
Notch U1: 607
frequency (SEGD) U2: 24
playback filter U3: 44
Num
Sensor Type, LT428 IM: 379
Number of
Auxes (SEGD) U2: 25
blocks of General Trailer (SEGD)
U2: 21
channel sets per record (SEGD) U2: 20
channels (SPS) U2: 75, U2: 87,
U2: 123, U2: 137
channels in this channel set (SEGD)
U2: 23
Index
720 428XL Users Manual Vol. 1
April 11, 2013
ABCDE F GHI J K L MNOP QRS T UVWXY Z
dead Seis traces (SEGD) U2: 25
DPG modules U1: 70
FDUs between LAUs, max IM: 341,
IM: 342
FDUs in link, LT428 IM: 407
FDUs in link, TMS428 TM: 122
geophones per trace U3: 240
live Seis traces (SEGD) U2: 25
plotters U1: 71
sample skew 32 byte extensions
(SEGD) U2: 20
samples in trace (SEGD) U2: 25
samples per trace U2: 32
samples per trace (SEGD) U2: 34
Seis traces (SEGD) U2: 25
splices, Fibre Optics TM: 342
stacks low (SEGD) U2: 42
stacks noisy (SEGD) U2: 42
subscans exponent (SEGD) U2: 23
traces (SEGD) U2: 25
traces, max U3: 289
vibrators in pattern, VE432 U1: 646
vibrators in pattern, VE464 U1: 530
windows (SEGD) U2: 27
windows, noise editing U1: 298
Numeric
pilot, additional U1: 518
pilot, choosing U1: 517
pilot, correlation U1: 258
view, Line window U1: 121
view, normal acquisition, OVC
U1: 692
view, normal acquisition, VE432
U1: 674
view, normal acquisition,
VE464,VE464 U1: 560
Nunits, len, width (SPS) U2: 76, U2: 77,
U2: 89, U2: 90, U2: 124, U2: 125,
U2: 139, U2: 140
Nut
wing, replacing TM: 284
NVIDIA IM: 205
Nyquist U1: 87
O
Observer
comments, setup U1: 302
privileges U1: 44
reports U1: 585
ODU IM: 484
Off
Line U1: 98
Offset
removing U3: 238
test U3: 172
test, Sensor U3: 193
to coord. location (SPS) U2: 73,
U2: 83, U2: 121, U2: 133
On
Line U1: 98
Only
errors, TMS428 report TM: 63
Open
session U1: 38
Test plan TM: 55
test report, TMS428 TM: 68
Operating
mode U1: 279
Operation
table U1: 244
Optical Fibre
TFOI, connecting IM: 336
Option
button U1: 25
Options
Navigation U1: 307
Slip-sweep U1: 282, U1: 332
Organization
code U2: 171
Orientation
LT428 IM: 386
pattern, VE432 U1: 647
pattern, VE464 U1: 531
plotter page U1: 608
test, LAUL (TMS428) TM: 109
Oscillator
local, testing (TMS428) TM: 106
Master (LCI) TM: 20
Index
428XL Users Manual Vol. 1 721
April 11, 2013
ABCDE F GHI J K L MNOP QRS T UVWXY Z
Output
Dump U1: 258
stack U1: 258
Xdump U1: 258
OVC U1: 683
Overload, APS U2: 163
P
Page
setup, plotter U1: 608
Parallel
geophone U3: 241
Parameters
loading (Log) U1: 574
saving (Log) U1: 574
saving/loading IM: 145
system, editing U1: 574
Parts
DSU-428, spare TM: 214
FDU, spare TM: 208
LAUL-428, spare TM: 223
LAUX-428, spare TM: 230
LAUXS-428, spare TM: 243
Password
DSUT TM: 146
expiry date U1: 43
opening a session U1: 40
Paste U1: 34
Patch
client IM: 187
server IM: 148
Path
colour U1: 119
Pattern
number, creating, VE432 U1: 646
number, creating, VE464 U1: 530
orientation, VE432 U1: 647
orientation, VE464 U1: 531
setup, VE432 U1: 646
setup, VE464 U1: 530
vibrator, choosing U1: 275
PC
Handheld, installing IM: 279
PCMCIA
tools, VE432 U1: 667
Peak
distortion, APS U2: 160
force, APS U2: 160
phase, APS U2: 160
Peg (see Topographic stake)
Period
monitoring, used disk space U1: 492
Periodical verification, DSUT TM: 130
Peripherals IM: 201
Install setup U1: 70
Permission U1: 44
Phase
angle (SEGD) U2: 22
Control (SEGD) U2: 22
error (Instrument test) U1: 218
Linear U1: 88
Minimum U1: 88
test, FDU U3: 173
test, TMS428 TM: 93
Phase test
DSU U3: 216, U3: 226
Phase, APS U2: 160
Pilot
basic signal, VE432 U1: 636
digital, additional U1: 518
digital, choosing U1: 517
digital, correlation U1: 258
length, other vibrator systems U1: 681
length, OVC U1: 686
Pilot length (SEGD) U2: 28
Ping IM: 50
Planting
tool, DSU3BV-428 IM: 333
tool, DSU-428 IM: 327
Plate Warning, APS U2: 162
Playback
filters U3: 43
record U1: 470
Plot U1: 608
abort U1: 594
Again U1: 594
Next U1: 594
Plotter
AGC U1: 604
Index
722 428XL Users Manual Vol. 1
April 11, 2013
ABCDE F GHI J K L MNOP QRS T UVWXY Z
banner U1: 595
ethernet, installing IM: 207
general IM: 33
licence IM: 198, U1: 68
mode, display U1: 609
name U1: 71
number of U1: 71
parameters U1: 604
processing U1: 604
scaling U1: 606
type U1: 71
Plug
cleaning IM: 316, TM: 293
process type, FO U1: 255
Plug, FM4
SRHRF cable TM: 309
ST+cable TM: 298
WPSR cable TM: 322
Point
Code, FDU2S channels U1: 181
Number (Marker) U1: 135
Point (to) U1: 26
Point Code
DSU channels U1: 163
FDU channels U1: 128
SPS U2: 79, U2: 93, U2: 127,
U2: 143
Point Depth (SPS) U2: 79, U2: 93,
U2: 127, U2: 143
Point Index
SPS U2: 79, U2: 80, U2: 93, U2: 97,
U2: 127, U2: 129, U2: 143,
U2: 147
Point Index, APS U2: 160, U2: 169
Point Index, format U2: 166
Point number
COG, format U2: 166
SPS U2: 79, U2: 80, U2: 93, U2: 97,
U2: 127, U2: 129, U2: 143,
U2: 147
Point number, APS U2: 160, U2: 169
Point record
description (SPS) U2: 93, U2: 143
specification (SPS) U2: 79, U2: 127
Polarity
3C U3: 277
battery, test (TMS428) TM: 102
FDU input IM: 511
FDU2S takeout IM: 515
SEGD U2: 20
test, FDU (TMS428) TM: 91
test, line power (TMS428) TM: 110
trace U3: 42
Port
consumption, TMS428 TM: 105
switching test (TMS428) TM: 109
voltage, testing (TMS428) TM: 103
Portrait
plotter U1: 608
Pos. proc. contractor (SPS) U2: 73,
U2: 83, U2: 121, U2: 133
POSC U2: 171
Positioning
contractor (SPS) U2: 73, U2: 83,
U2: 121, U2: 133
layers U1: 403
Post-annotation
logging U1: 89
Post-plot date of issue (SPS) U2: 73,
U2: 82, U2: 121, U2: 132
Power
connector, LAUL-428 IM: 512
connector, LAUX IM: 513
polarity, line (TMS428) TM: 110
requirements IM: 51
socket, replacing TM: 287
test, LAU TM: 101
Power supply
field electronics IM: 340
Power-off
Line, LT428 IM: 387
Power-on
Line, LT428 IM: 387
LT428 IM: 371
test, LT428 IM: 387
Transverse, LT428 IM: 395
Power-up
TMS428 TM: 50
P-P bar/m,prim/bubble (SPS) U2: 92,
U2: 142
Index
428XL Users Manual Vol. 1 723
April 11, 2013
ABCDE F GHI J K L MNOP QRS T UVWXY Z
Preamplifier
0 dB gain, FDU calibration U3: 131
12 dB gain, FDU calibration U3: 160
Pressure
sensor, enabling, VE464 U1: 551
Pressure Overload, APS U2: 163
Prestack within field units (SEGD)
U2: 27
Preview
colour mapped attributes U1: 449
Printer IM: 33
Privileges U1: 44
Process
Type setup, generating U1: 272
type, Log shooting setup U1: 577
type, overview U1: 254
Type, SEGD U2: 27
Type, setup U1: 275
Processing
capacity U3: 287
Crossline spacing, plotter U1: 606
filter, plotter U1: 607
Geographic AGC, plotter U1: 605
Inline spacing, plotter U1: 606
Normalization, plotter U1: 605
plotter U1: 604
Time, exponential U1: 605
Window length (AGC) U1: 605
Wz velocity, plotter U1: 605
Producer
code U1: 91
Project code and description (SPS)
U2: 74, U2: 86, U2: 122, U2: 136
Projection U1: 454
type (SPS) U2: 73, U2: 84, U2: 121,
U2: 134
type, setup U1: 409
zone (SPS) U2: 73, U2: 84, U2: 121,
U2: 135
Projection Type setup
Projection U1: 454
Properties
in graphic view, Line U1: 117
Look, Line U1: 149
object label U1: 448
test plan, TMS428 TM: 61
Property
name, query builder U1: 451
Protocol
source controllers U3: 97
Pseudorandom
basic sweep signal, VE432 U1: 628
basic sweep signal, VE464 U1: 507
Pulse
basic sweep signal, VE432 U1: 627
basic sweep signal, VE464 U1: 511
Instrument test U1: 218
Sensor test U1: 221
test, FDU U3: 186
Q
Q200 IM: 369
Backup IM: 311
Battery IM: 307
connecting IM: 370
Getting started IM: 371
installing IM: 308
quick guide IM: 305
Reinstalling IM: 312
QC
choice, VE432 vib U1: 643
choice, VE464 vib U1: 528
data (How to view) U1: 116
extended, VE432 vib U1: 643
extended, VE464 vib U1: 529
limits, OVC U1: 688
limits, VE432 vib U1: 642
limits, VE464 vib U1: 527
QT-400 IM: 365
Quadrant bearing of H256 (SPS) U2: 74,
U2: 86, U2: 122, U2: 136
Quality
COG radius threshold U1: 412
Control IM: 33
Vib position accuracy U1: 413
warning setup U1: 411
Quality Control
check records (SPS) U2: 78, U2: 126
Query
add to U1: 452
Index
724 428XL Users Manual Vol. 1
April 11, 2013
ABCDE F GHI J K L MNOP QRS T UVWXY Z
builder U1: 451
Quick
Launch, TMS428 tests TM: 62
tester, QT-400 IM: 365
R
R,S,X file quality control (SPS) U2: 78,
U2: 126
Radio
bridge, ethernet IM: 483
delay, measuring, VE432 U1: 662
Delay, VE432 U1: 660
delay, VE432 U1: 664
management, VE432 vib U1: 639
management, VE464 vib U1: 520
telemetry, deployment IM: 411
telemetry, setting up U1: 196
Radius
alarm, distance to camp U1: 445
alarm, distance to recording unit
U1: 445
shooting setup, Log U1: 577
Random
basic sweep signal, VE432 U1: 628
basic sweep signal, VE464 U1: 507
Lift up delay, VE464 U1: 545
Rate
refresh U1: 54
sample U1: 87
Raveon radio
setup U1: 524
Raw
Impulsive Stack process type U1: 265
process type, Correlation U1: 267
servo control, VE432 U1: 666
servo control, VE464 U1: 544
Vib Stack process type U1: 270
Rcv
Nb Increment, LT428 IM: 378
Read
traceability, FDU (TMS428) TM: 96
traceability, LAU (TMS428) TM: 115
user info (TMS428) TM: 112
Ready
fleet U1: 291
Re-assembling
DSU TM: 217
FDU2S TM: 269
LAULS TM: 274
LAUXS TM: 279
Reassembling
FDU TM: 210
LAUL TM: 226
LAUR TM: 250
LAUX-428 TM: 232
LAUX-G TM: 238
LAUXS TM: 244
LRU TM: 258
TFOI TM: 373
TFOI-G TM: 357
TREP-428 TM: 265
Reboot
server U1: 47
Receiver
code (Rx) tables (SPS) U2: 76,
U2: 124
index (SPS) U2: 80, U2: 98, U2: 129,
U2: 148
line number (SEGD) U2: 34
point easting (SEGD) U2: 36
point elevation (SEGD) U2: 36
point index (SEGD) U2: 34
point northing (SEGD) U2: 36
point number (SEGD) U2: 34
point, skipping U1: 147, U1: 157
position history U1: 588
section U1: 127
section, marking U1: 134
Tilt model, LT428 IM: 390
Type Layout, LT428 IM: 379
Record
disk, setup U1: 93
identification (SPS) U2: 79, U2: 80,
U2: 127, U2: 129
identification, APS U2: 160, U2: 169
identification, COG, format U2: 166
Instrument tests U1: 214
last, playback U1: 471
length (SEGD) U2: 28
length, Intrument tests U1: 217
length, process type U1: 255
Index
428XL Users Manual Vol. 1 725
April 11, 2013
ABCDE F GHI J K L MNOP QRS T UVWXY Z
next, playback U1: 472
test result recovery U3: 113
type (SEGD) U2: 20
Record length U3: 289
SEGD U2: 20
Recovering
instrument test records U3: 113
Recovery
line error, Micro-seismic U1: 370
Redhat
installing, client IM: 161
installing, server IM: 94, IM: 110
Reference
DSU3, DSUT TM: 131, TM: 158
latitude, vibrator guidance U1: 284
resistors, calibration U3: 129
signal, VE432 DSD U1: 640
voltage, calibration U3: 129
voltage, FDU (TMS428) TM: 94
voltage, FDU calibration U3: 131
Refraction
delay, process type U1: 256
delay, SEGD U2: 26
Refresh
rate U1: 54
Registering
user U1: 43
Reinstalling
TMS428 software TM: 40
Relation record
description (SPS) U2: 97, U2: 147
specification (SPS) U2: 80, U2: 129
Release
tape drive U1: 469
Remote
connection to server, Linux IM: 190
connection to server, Windows
IM: 191
network IM: 40, IM: 41, IM: 42
user U1: 39
user, installing IM: 179
Rename
layers (Positioning) U1: 420
Rendering
global, plotter U1: 609
setup, plotter U1: 608
Repair
assistant, DSU TM: 164, TM: 166
LCI-428 TM: 21
log file, DSUT TM: 166
Repairing
SRHRF cable TM: 303
ST cable TM: 294
ST+cable TM: 294
WPSR cable TM: 303
Repeater
LAUX-428, Marker setup U1: 134
Raveon radio U1: 525
Tracs TDMA U1: 523
Transverse IM: 339
Replacing
cable, LAUL TM: 224
cable, TFOI TM: 363
cable, TFOI-G TM: 352
connector, Fibre Optics TM: 392
FDU connector TM: 284
ground wing nut TM: 284
indicators TM: 290
LCI-428 U1: 64
Line & Trans sockets TM: 285
Power socket TM: 287
TFOI board TM: 368
XDEV sockets TM: 288
Reply
alarm U1: 444
Report
APS U1: 587
COG U1: 587
errors only (TMS428) TM: 63
generate, query U1: 452
Observer U1: 585
publishing
Publish
reports U1: 571
receiver position U1: 588
test, TMS428 TM: 66
Repository U1: 66
Rescue
NAS system IM: 244
Reset
button U1: 32
Index
726 428XL Users Manual Vol. 1
April 11, 2013
ABCDE F GHI J K L MNOP QRS T UVWXY Z
Meter TM: 56
queries and classification U1: 450
Tester Unit TM: 56
Resetting
CN3e IM: 292
GoBook Q200 IM: 306
Reshoot U1: 286
Reshot U1: 286
Resistance
error (SEGD) U2: 37
high limit (SEGD) U2: 37
input, FDU calibration U3: 135
low limit (SEGD) U2: 37
Sensor test U1: 219
test network, FDU calibration U3: 144
test, FDU U3: 168
test, Field (TMS428) TM: 91
test, Instrument (TMS428) TM: 92
test, Sensor U3: 194
value (SEGD) U2: 37
Response, Channel filter U3: 55
Restart
server U1: 47
Retrieval
Wireline telemetry U1: 99
Return
Pilot, VE432 U1: 640
signal, VE432 DSD U1: 639
sweep, VE432 vib U1: 640
Reverse
button U1: 32
Reversed
Marking option U1: 136
Revision
SEGD U1: 91
Revision Number (SEGD) U2: 21
Rewind
tape U1: 469
Right
click, Line window U1: 117
Role U1: 44
Run
LED, testing (TMS428) TM: 103
TMS428 tests TM: 56
Running
Line tests, LT428 IM: 384
Tests
DSUT TM: 156
tests, TMS428 TM: 64
Transverse tests, LT428 IM: 394
RVT300 IM: 275
S
S N (serial number)
detour U1: 141
Sample
conversion to mV U3: 235
int. Record Len. (SPS) U2: 75,
U2: 123
int., Record Length (SPS) U2: 87,
U2: 137
interpolation U3: 249
Rate U1: 87
Rate, LT428 IM: 379
skew extensions, number of U2: 20
skew, SEGD U2: 33
to mV conversion factor U2: 42
Sample Rate
SEGD U2: 25
Samples
in trace, number of U2: 25
per trace, number of U2: 32, U2: 34
Save
Rcv Tilt Model, LT428 IM: 390
Thresh U1: 301
Saving
automatic, TMS428 reports TM: 62
results, LT428 IM: 401
system parameters U1: 575
Saving, automatic
DSUT TM: 161
Scalability
installation settings U1: 75
Scale
button U1: 26
factor (SPS) U2: 74, U2: 85, U2: 122,
U2: 135
histograms U1: 123
Scaling
plotter U1: 606
Index
428XL Users Manual Vol. 1 727
April 11, 2013
ABCDE F GHI J K L MNOP QRS T UVWXY Z
Scan Type
Header (SEGD) U2: 23
Number (SEGD) U2: 33
per record (SEGD) U2: 20
Scrollbar U1: 26
Sealing TM: 292
Searching
LT428 results IM: 400
Second
Notch Frequency (SEGD) U2: 24
of minute (SEGD) U2: 19
SEGD
3C polarity U3: 277
Code U1: 131
format U2: 15
format, Rev 2.1 U2: 45
revision, choosing U1: 91
setup U1: 90
Trace Blocking U1: 465
Seis traces, number of U2: 25
Seismic
datum (SPS) U2: 79, U2: 94, U2: 127,
U2: 144
instrument header records (SPS)
U2: 87, U2: 137
receiver header records (SPS) U2: 89,
U2: 139
setup, Operation U1: 279
source header records (SPS) U2: 90,
U2: 140
trace scaling U1: 606
Seismonitor U1: 114
DSUT TM: 159
gain U1: 114
Sensor test U1: 223
Select U1: 26
VE432 vib (Look) U1: 651
Selecting
graphical objects U1: 34
in graphic view U1: 115
table cells U1: 33
text U1: 33
traces to plot U1: 601
Selection
create U1: 452
Self-test
LAU (TMS428) TM: 100
LT428 IM: 373
Senior
Observer, privileges U1: 44
Sensor
Coulour code U1: 109
Leakage test U1: 220
Noise test U1: 220
num/Rcv pnt, LT428 IM: 379
Pulse test U1: 221
Resistance test U1: 219
Seismonitor U1: 223
sensitivity (SEGD) U2: 40
show/hide U1: 109
test limits U1: 129
tests U1: 219
tests, CMRR U3: 202
tests, Distortion U3: 207
tests, FDU U3: 191
tests, Impulse U3: 205
tests, Leakage U3: 197
tests, Look U1: 150
tests, Noise (FDU) U3: 191
tests, Offset U3: 193
tests, Resistance U3: 194
tests, Tilt U3: 200
Tilt model U1: 220
Tilt test U1: 220
Type, FDU2S channels U1: 181
Type, LT428 IM: 379
Sensor Type
DSU channels U1: 162
FDU channels U1: 129
Number (sensor tests) U2: 36
SEGD code U2: 35
Sequence
Line, SPS U2: 121, U2: 133
test, DSUT TM: 154
Sequencer
Shallow U3: 105
Sequential
time, plotter U1: 609
trace, plotter U1: 609
Serial
number, changing (TMS428) TM: 116
Index
728 428XL Users Manual Vol. 1
April 11, 2013
ABCDE F GHI J K L MNOP QRS T UVWXY Z
number, detour U1: 141
number, tape U1: 92
Series
geophones U3: 241
Server
administration U1: 42
connectors IM: 71
FTP U1: 72
log on to U1: 38
NFS U1: 72
software, installing IM: 93, IM: 140
start/stop U1: 47
Server ID IM: 197, U1: 67
Servo
input, VE432 U1: 665
input, VE464 U1: 544
setting, VE432 U1: 665
setting, VE464 U1: 543
Session
manager U1: 45
opening U1: 38
Set
channel, number per record U1: 91
DSD, OVC U1: 690
Guidance, VE464 U1: 552
Servo, VE432 U1: 665
Servo, VE464 U1: 543
tape U1: 96
tape, creating U1: 463
VE432 DSD U1: 656
VE464 DSD U1: 539
Sets, channel U2: 20
Settings
browser U1: 40
help U1: 40
Setup
Crew, OVC U1: 685
DSUT TM: 152
Observer comments U1: 302
VE432 Crew, vibrators U1: 616
VE464 Crew, vibrators U1: 496
SFL
Spread First Line U1: 275
SFN
Spread First Number U1: 275
SGD-S
Blaster cable IM: 517
SGDS U3: 108
SGS
shooting system U1: 71
SH geophone IM: 321
Shallow
mode, enabling U1: 280
Sequencer U3: 105
Shallow-water U1: 379
Shapefile U1: 421
Shock
mount parts IM: 70
Shock-mount
Cartridge drive IM: 213
NAS system IM: 232
NAS4000 IM: 250
Shooter U1: 303
Shooting U1: 303
LSI IM: 360
LSS IM: 29, U1: 309
Navigation mode U1: 306
setup, Log U1: 576
system U1: 70
system, connecting IM: 57
systems, interfacing U3: 97
Shortcut
Line window U1: 117
Shortcuts
tests TM: 59
Shot
automation U1: 280
Depth, charge len. (SPS) U2: 78,
U2: 126
depth, charge len. (SPS) U2: 91,
U2: 141
Id U1: 273
Id, Log shooting setup U1: 577
increment U1: 288
Nb, APS U2: 162
number (SEGD) U2: 25
starting U1: 249
ShotPro
install U1: 70
interfacing U3: 101
Index
428XL Users Manual Vol. 1 729
April 11, 2013
ABCDE F GHI J K L MNOP QRS T UVWXY Z
wiring IM: 518, IM: 519
Show
layer (Positioning) U1: 420
Shutdown
server U1: 47
Signal
return sweep, VE432 U1: 640
Similarities
VE464, radio U1: 553
Similarity
test, radio, VE432 U1: 640
Simultaneous mode U3: 287
Single
mode, recording specifications U3: 287
Size
external header U1: 91
vert. stk fold (SPS) U2: 77, U2: 125
Size, vert. stk fold (SPS) U2: 90, U2: 140
Skew, sample, number of extensions
U2: 20
Skip
channel U1: 153
Skipping
lines (spread description) U1: 148
receiver points U1: 147
receiver points (detour) U1: 157
Slave
428XL U3: 98
Ethernet radio bridge IM: 487
VE432 DPG U1: 617
VE464 DPG U1: 497
Slave. See Master/Slave.
Sleep
LRU U1: 211
Slip
time U1: 332
time, selecting U1: 293
Slip-sweep IM: 56, U1: 332
enable U1: 282
mode used (SEGD) U2: 28
Snaking U1: 136
DSU U1: 165
FDU U1: 158
FDU2S U1: 192
Software
e428, licence U1: 67
Handheld PC, installing IM: 279
installing, GoBook IM: 308
installing, TMS428 TM: 37
New release TM: 46
patch (client) IM: 187
patch (server) IM: 148
updating U1: 235
version (SEGD) U2: 28
Software, installing
CN3e IM: 296
server IM: 140
Soil, drill method (SPS) U2: 78, U2: 91,
U2: 126, U2: 141
Source
aux nb (SEGD) U2: 28
code (Sx) tables (SPS) U2: 77,
U2: 125
COG file, format U2: 166
control, LSS IM: 29, IM: 360
controller, in line IM: 360
controller, time management U1: 89
easting (SEGD) U2: 28
elevation (SEGD) U2: 28
Explosive U1: 288
Line U1: 274
line bearing, VE432 U1: 648
line bearing, VE464 U1: 532
Line Number (SEGD) U2: 22
northing (SEGD) U2: 28
Point Index U1: 244
Point Index (SEGD) U2: 22
Point Number (SEGD) U2: 22
point setup, generating U1: 278
point, setup U1: 273
Receiver U1: 274
Set Number (SEGD) U2: 22
type, setup U1: 287
Source controllers U3: 97
Space, disk
DSUT TM: 143
Spacing
crossline (AGC) U1: 606
DSU3 IM: 342
FDU IM: 341
inline (AGC) U1: 606
Index
730 428XL Users Manual Vol. 1
April 11, 2013
ABCDE F GHI J K L MNOP QRS T UVWXY Z
LAU IM: 341
Spare
DSU-428 parts TM: 214
FDU parts TM: 208
LAUL-428 parts TM: 223
LAUX-428 parts TM: 230
LAUXS-428 parts TM: 243
Spatial
filtering, Positioning window U1: 404
query U1: 419
Specifications
428XL U3: 281
DSUT TM: 128
Instrument tests U3: 296
laser link IM: 481
TMS428 TM: 31
Speed
alarm U1: 447
maximum U1: 446
maximum, scale U1: 414
Spike
editing U1: 386
Splicing
SRHRF cable TM: 303
ST+cable TM: 294
WPSR cable TM: 303
Split
line U1: 136
Spread
absolute U1: 144
generic U1: 146
layout conventions IM: 346
number (SEGD) U2: 25
setup U1: 143
SFL U1: 275
SFN U1: 275
Superspread U1: 276
Superspread, Line window U1: 145
type U1: 274
type (SEGD) U2: 26
SPS
exporting U1: 583
format, initial U2: 65
importing U1: 581
Rev. 2.1 U2: 111
Sercel (over 10000 traces) U2: 108
SPS-like file format U2: 159
SQC
dump to U1: 280
dump, VE432 U1: 359
dump, VE464 U1: 346
SQC Dump mode U1: 346
SRHRF cable
splicing TM: 303
SSMon
software, installing IM: 287, IM: 302
ST cable
splicing TM: 294
ST+cable
splicing TM: 294
Stack
Correlation after, process type U1: 268
Correlation before, process type
U1: 266
distance, VE432 U1: 647
distance, VE464 U1: 531
Impulsive, process type U1: 265
Output button U1: 258
Vibroseismic, process type U1: 270
Stacking Fold
SEGD U2: 27
Stacking Fold, APS U2: 163
Stacks, number of
Low U2: 42
Noisy U2: 42
Stake (see Topographic stake)
Standard
process type U1: 255
Start
colour map scale U1: 449
time, plotter U1: 610
Starting
428 server U1: 47
DSUT428 TM: 146
FDPA428 IM: 443
LT428 IM: 371
TMS428 TM: 49
Static correction (SPS) U2: 79, U2: 93,
U2: 127, U2: 143
Statics U3: 249
Statistics
Index
428XL Users Manual Vol. 1 731
April 11, 2013
ABCDE F GHI J K L MNOP QRS T UVWXY Z
DSUT TM: 169
OVC U1: 694
VE432 U1: 677
VE464 U1: 564
Status
codes, VE432 DPG and DSD U1: 676
codes, VE464 DPG and DSD U1: 562
VE432 DSD, get U1: 639
VE464 DSD, get U1: 529
Step
negative U1: 322
Vibroseismic source U1: 290
Stiffness (ground), APS U2: 160
Stop
button, Operation U1: 249
Marking U1: 142
on error, TMS428 TM: 62
Stopping
428 server U1: 47
Strain-relief
TFOI-428 IM: 337
TFOI-G TM: 400
Streamer cable number (SEGD) U2: 24
String
gain, geophone U3: 241
group, geophone U3: 245
impedance, geophone U3: 241
wiring, geophones U3: 246
Subarrays, number of U2: 92, U2: 142
Submersible
electronics IM: 350
Subscan exponent U2: 23
Superspread U1: 276
Line window U1: 145
Support
customer U1: 83
Surface
elevation, reference U1: 410
elevation, SPS U2: 79, U2: 127
Surface elevation
SPS U2: 94, U2: 144
Survey
description U1: 126
setup U1: 125
Swath
backup setup U1: 94
first line (SEGD) U2: 25
first number (SEGD) U2: 25
name U1: 96
number U1: 95
type U1: 578
Sweep
basic signal, VE432 (Acquisition type)
U1: 636
basic signal, VE464 (Acquisition type)
U1: 517
freq start, end (SPS) U2: 77, U2: 125
frequency start,end (SPS) U2: 91,
U2: 141
length (SEGD) U2: 28
length, other vibrator systems U1: 680
length, OVC U1: 686
return signal, VE432 U1: 640
slip time U1: 332
slip, enable U1: 282
type, length (SPS) U2: 77, U2: 91,
U2: 125, U2: 141
Switching
port (TMS428) TM: 109
Sync
high line, VE432 U1: 637
high line, VE464 U1: 518
Syntax (see Description)
Synthetic
file format U2: 57
file syntax U1: 231
Signal type U1: 231
System
shooting U1: 70
tools, troubleshooting IM: 157
T
T0
mode, VE432 U1: 645
Repeat Times, VE432 U1: 644
setup, VE432 U1: 644
Table
how to select U1: 33
operation U1: 244
Tap
Index
732 428XL Users Manual Vol. 1
April 11, 2013
ABCDE F GHI J K L MNOP QRS T UVWXY Z
test, LT428 IM: 376, IM: 404
Tape
copy U3: 16
drive IM: 33
drive address
FUJ I 3x90, displaying IM: 216
drive, install U1: 72
Label U1: 464
label (SEGD) U2: 28
label, external U1: 92
Number U1: 464
number of files U1: 465
number, SEGD U2: 28
set U1: 96
set, creating U1: 463
setup, Export window U1: 463
type, format, density (SPS) U2: 75,
U2: 87, U2: 123, U2: 137
Tape drive
address
3592 IM: 225
FUJ I 3x90, changing IM: 215
LTO IM: 221
exporting to U1: 458
installing IM: 213
interface card IM: 76
supported IM: 214
Tape/disk identifier (SPS) U2: 73,
U2: 82, U2: 121, U2: 132
Taper
length start, end (SPS) U2: 77, U2: 91,
U2: 125, U2: 141
VE432 U1: 619
VE464 U1: 500
TB
window, process type U1: 256
window, SEGD U2: 25
Tb to T0 time (SEGD) U2: 27
TB window
LSS U1: 310
TCXO, LCI board TM: 20
TDMA U1: 520
channel, Tracs TDMA U1: 522
Template
TMS428 tester TM: 49
Terminal
Linux IM: 157
Test
acceptance U3: 263
Automatic U1: 285
cable calibration TM: 57
customizing (TMS428) TM: 81
functions U1: 213
functions, FDU U3: 163
generator, FDU calibration U3: 135
Instrument, FDU U3: 168
limit
battery U1: 113
Continuity U1: 130
Leakage U1: 130
Noise U1: 130
Sensor U1: 129
Tilt U1: 130
limit file format U2: 53
limits, LT428 IM: 375, IM: 381
multiple U1: 222
network, Resistance, FDU calibration
U3: 144
record result recovery U3: 113
Record, type (SEGD) U2: 25
Running, DSUT TM: 156
running, TMS428 TM: 64
Sensor, FDU U3: 191
sequence editor, DSUT TM: 154
setup U1: 213
shortcut (Topographic view) U1: 109,
U1: 111
Spread U1: 215
System, TMS428 IM: 35
Test plan
TMS428 TM: 60
Test report
DSUT TM: 172
Test system
TMS428 TM: 29
Tested
Line Nb, LT428 IM: 378
Tester
cable TM: 195
reset TM: 56
Text
Index
428XL Users Manual Vol. 1 733
April 11, 2013
ABCDE F GHI J K L MNOP QRS T UVWXY Z
box U1: 26
how to select U1: 33
TFOI
board, replacing TM: 368
cable TM: 363
connecting IM: 336
disassembly instructions TM: 364
reassembly instructions TM: 373
TFOI-G IM: 37
cable TM: 352
disassembly instructions TM: 353
reassembly instructions TM: 357
strain-relief TM: 400
Third Notch Frequency (SEGD) U2: 24
Threshold
COG radius U1: 412
Hold/Var (SEGD) U2: 27
Init U1: 300
Init Value, noise editing U1: 299
Load U1: 300
Save U1: 301
type tables (SEGD) U2: 27
type, other vibrator systems U1: 681
type, OVC U1: 686
updating (noise elimination) U1: 387
Tilt
correction, enable U1: 66, U1: 177
error (SEGD) U2: 37
limit (SEGD) U2: 37
Model U1: 220
test U1: 220, U3: 200
DSU TM: 178
Test limit U1: 130
test, Field (TMS428) TM: 90
test, theory U3: 221, U3: 230
value (SEGD) U2: 37
Tilt angle
DSU3 trace correction formula U3: 261
Time
delay, FTB-SOD (SPS) U2: 75,
U2: 88, U2: 123, U2: 138
Division Multiplex, LRU U1: 204
domain, correlation U3: 232
exponential, plotter U1: 605
Interpolation U1: 610
Length, plotter U1: 610
listening U1: 256
management U1: 88
Sequential, plotter U1: 609
SPS U2: 79, U2: 95, U2: 127,
U2: 145
Start, plotter U1: 610
Time break
SEGD U2: 26
window, SEGD U2: 33
Time, APS U2: 163
TMS428 IM: 35, TM: 29
Connecting an FDU link TM: 70
Connecting an FDU2S TM: 71
Connecting an LAUL TM: 72
Connecting an LAULS TM: 73
Connecting an LAUX TM: 74
Connecting an LAUXS TM: 80
Connecting an LAUXS-428 TM: 78
customizing tests TM: 81
FDU calibration U3: 128
firmware update TM: 56
Grounding TM: 35
installation TM: 35
main window TM: 54
software, installing TM: 37
specifications TM: 31
Templates TM: 49
Test plan TM: 60
test reports TM: 66
TMS428 specifications
Electrical TM: 33
Environmental TM: 34
Physical TM: 34
TMU428 TM: 30
Calibration TM: 121
FDU calibration U3: 128
Tn
basic sweep signal, VE432 U1: 626
basic sweep signal, VE464 U1: 506
Tn, VE432 U1: 626
Tn, VE464 U1: 506
To channel (SPS) U2: 80, U2: 97,
U2: 129, U2: 147
To receiver (SPS) U2: 80, U2: 98,
U2: 129, U2: 148
Index
734 428XL Users Manual Vol. 1
April 11, 2013
ABCDE F GHI J K L MNOP QRS T UVWXY Z
Toggle
button U1: 27
Toolbar
tests TM: 59
Tools
maintenance, field electronics TM: 206
Meter and test cables calibration
TM: 57
PCMCIA, VE432 U1: 667
Reset Meter TM: 56
Reset Tester Unit TM: 56
SRHRF cable splicing TM: 303
ST+cable splicing TM: 294
ST+FM4 plug replacement TM: 298
STSR FM4 plug replacement TM: 322
TMS428 TM: 56
USB key management IM: 157
WPSR cable splicing TM: 303
WPSR FM4 plug replacement TM: 322
Topographic
stake U1: 109
view U1: 105
Total number of traces (SEGD) U2: 25
Towing depth U2: 92, U2: 142
Trace
auxiliary, description U1: 261
blocking U1: 465
data block U2: 32
edit (SEGD) U2: 33
Low U1: 299
Noisy percentage U1: 299
Number (SEGD) U2: 33
number of samples in U2: 25
polarity U3: 42
selecting, plot U1: 601
Sequential, plotter U1: 609
Trace Header
Extension (SEGD) U2: 33
Extension Block 1 (SEGD) U2: 34
Extension block 2 (SEGD) U2: 36
Extension block 3 (SEGD) U2: 37
Extension block 4 (SEGD) U2: 38
Extension block 5 (SEGD) U2: 38
Extension block 6 (SEGD) U2: 39
Extension block 7 (SEGD) U2: 41
Extensions (SEGD) U2: 24, U2: 34
SEGD U2: 33
Traceability
DSU LP board TM: 166
FDU, read (TMS428) TM: 96
FDU, write (TMS428) TM: 96
field equipment U1: 120
LAU, read (TMS428) TM: 115
LAU, write (TMS428) TM: 115
Traces
max number of U3: 289
per inch U1: 609
total number of U2: 25
Traces, number of
Aux U2: 25
Dead seis U2: 25
Live seis U2: 25
Seismic U2: 25
Tracking
box, installing IM: 278
Positioning window U1: 432
VE464 U1: 522
vehicle setup U1: 414
Tracs TDMA
Baud rate U1: 522
Trailer, general U2: 21
Trans
socket, replacing TM: 285
Transfer
to drive, spec U3: 287
Transform
Hilbert, VE432 U1: 631
Transmission
Line port (TMS428) TM: 107
test IM: 396
test, Line (LT428) IM: 388
Transverse port (TMS428) TM: 107
troubleshooting U1: 119
Transverse
connector, LAUX IM: 513
data rate U3: 287
port, transmission test (TMS428)
TM: 107
test, LT428 IM: 376
Transverse (LT428) IM: 396
TREP-428
Index
428XL Users Manual Vol. 1 735
April 11, 2013
ABCDE F GHI J K L MNOP QRS T UVWXY Z
connecting IM: 339
disassembly instructions TM: 264
reassembly instructions TM: 265
Troubleshooting
DSU TM: 163
Line U1: 225
tools, system IM: 157
Transmission U1: 119
Type
blaster U1: 70
box, detour U1: 141
Model, Polarity (SPS) U2: 75, U2: 76,
U2: 77, U2: 87, U2: 89, U2: 90,
U2: 123, U2: 124, U2: 125,
U2: 137, U2: 139, U2: 140
of process (SEGD) U2: 27
of source (SEGD) U2: 25
plotter U1: 71
U
ULS technology IM: 30
deployment IM: 350
Handling IM: 356
in Line window U1: 178
Uninstalling
client software IM: 200
patch (client) IM: 187
patch (server) IM: 148
server software IM: 146
Unit
serial number (SEGD) U2: 39
type (SEGD) U2: 39
Units
how to select U1: 115
spacing X, Y (SPS) U2: 76, U2: 77,
U2: 89, U2: 90, U2: 124,
U2: 125, U2: 139, U2: 140
Unload
tape U1: 469
Unmanned
configuration IM: 78
installation parameters U1: 79
option, enabling U1: 65
Unselect
in Line topographic view U1: 115
Update
field U1: 103, U1: 149, U1: 219,
U1: 220
VE464 vib fleet U1: 537
Updating
firmware U1: 235
firmware (TMS428) TM: 112
firmware, via XDEV IM: 152
Number of FDUs in link, (LT428)
IM: 407
Number of FDUs in link, (TMS428)
TM: 122
TMS428 firmware TM: 56
Upgrade
firmware (TMS428) TM: 112
Upgrading
built-in LAUX TM: 118
field electronics U1: 235
TMS428 firmware TM: 56
via XDEV, field electronics IM: 152
Uphole
time (SEGD) U2: 26
time (SPS) U2: 79, U2: 94, U2: 127,
U2: 144
Upload U1: 60
UPS
configuration IM: 79
URL
opening a session U1: 39
USB
key IM: 157
User
account IM: 174
info U1: 90
interface table, DSUT TM: 150
local IM: 39
name U1: 59
registering U1: 43
remote IM: 40, IM: 41, IM: 42
Utilities
LAU (TMS4028) TM: 111
V
V12 IM: 209
Index
736 428XL Users Manual Vol. 1
April 11, 2013
ABCDE F GHI J K L MNOP QRS T UVWXY Z
VA (plotter) U1: 609
Values
query builder U1: 452
Valve Overload, APS U2: 163
Var/Hold U1: 300
VE432
connecting IM: 56
DPG, connecting IM: 56
functions U1: 650
Version, APS U2: 163
VE464
connecting IM: 55
functions U1: 534
Vehicle
Tracking box IM: 278
Velocity
baseplate, monitoring, VE432 U1: 640
mass, monitoring, VE432 U1: 640
plotter U1: 605
Verbose
APS report U1: 587
Veritas IM: 209
Version
firmware, reading (TMS428) TM: 111
Vertical
datum description (SPS) U2: 73,
U2: 84, U2: 121, U2: 134
Stack (SEGD) U2: 24
Vib
position accuracy U1: 413
position Easting, APS U2: 160
position elevation, APS U2: 160
position Northing, APS U2: 160
Status Code, APS U2: 162
Vibrator
drive level (APS) U2: 160
fleet (APS) U2: 160
guidance U1: 376
guidance, enabling U1: 284
number (APS) U2: 160
pattern setup, VE432 U1: 646
pattern setup, VE464 U1: 530
QC choice, VE432 U1: 643
QC choice, VE464 U1: 528
QC limits, OVC U1: 688
QC limits, VE432 U1: 642
QC limits, VE464 U1: 527
Radio management, VE432 U1: 639
Radio management, VE464 U1: 520
signals, recording IM: 345
T0, VE432 U1: 644
type U1: 70
type (SEGD) U2: 22
VE464 Fleet function U1: 535
Vibroseis (SPS) U2: 77, U2: 125
View
Graphic, OVC (normal acquisition)
U1: 690
Graphic, VE432 (normal acquisition)
U1: 671
Graphic, VE464 (normal acquisition)
U1: 557
Histogram U1: 123
menu, TMS428 TM: 57
numeric, Line window U1: 121
Numeric, OVC (normal acquisition)
U1: 692
Numeric, VE432 (normal acquisition)
U1: 674
Numeric, VE464 (normal acquisition)
U1: 560
topographic, line U1: 105
Vigor
installing, operating system IM: 133
Viscosity (ground), APS U2: 160
Voltage
port (TMS428) TM: 103
reference, FDU (TMS428) TM: 94
reference, FDU calibration U3: 131
VP
grabbing radius U1: 412
Id U1: 273
to do, increment U1: 290
VSR
deployment IM: 345
enable U1: 280
Hilbert transform, VE432 U1: 631
VE432 U1: 359
VE464 U1: 346
Index
428XL Users Manual Vol. 1 737
April 11, 2013
ABCDE F GHI J K L MNOP QRS T UVWXY Z
W
Warnings
DSUT TM: 181
Water
depth (SPS) U2: 79, U2: 94, U2: 127,
U2: 144
gun (SPS) U2: 78, U2: 126
Watertightness TM: 292
Waypoint
first U1: 415
Weathering thickness (SPS) U2: 78,
U2: 91, U2: 126, U2: 141
Wiggle U1: 609
Window
Length, AGC U1: 605
menu, TMS428 TM: 57
Number of (noise) U1: 298
TB U2: 25
TB, process type U1: 256
Wing
nut, replacing TM: 284
Wireless IM: 490
WPSR cable
splicing TM: 303
Write
traceability, FDU (TMS428) TM: 96
traceability, LAU (TMS428) TM: 115
user info (TMS428) TM: 112
Wz Velocity, AGC U1: 605
X
XDEV
connector, LAUL IM: 509, IM: 512
connector, LAUX IM: 514
socket, replacing TM: 288
upgrading field electronics IM: 152
Xdump
Output button U1: 258
Xmit
test, Line ( LT428) IM: 388
test, Transverse (LT428) IM: 396
Y
Year (SEGD) U2: 19
Z
Zeroed
channel U1: 142
Zeroing
Length (noise) U1: 298
method (noise elimination) U1: 387
noise editing type U1: 298
Taper Length (noise) U1: 298
Zoom
Line window U1: 116
Index
738 428XL Users Manual Vol. 1
April 11, 2013
ABCDE F GHI J K L MNOP QRS T UVWXY Z

También podría gustarte