Approximately 80,000 GSF Four stories in height with a partial basement and mechanical penthouse. This facility will accommodate program space for student organizations, leadership and some administrative functions that provide student assistance.

Site Plan

Structural Design Criteria

Foundation Plan - Basement


AREA 2
AREA 1

Foundation Plan Area 1


5 thick slab-on-grade with synthetic fibers typ. Basement walls designed to be supported at footing and 1st level composite slab

Column footing designed for a net bearing pressure of 8000 psf

Control and column isolation joint typ

Typical Column Footing Detail

Typical Column Footing Detail

Typical Basement Walls

Typical Slab-on-Grade Detail

Typical Slab Control Joint Detail

Control and Isolation Joint

Foundation Plan Area 2

Detail at Existing Tunnel

Detail at Existing Tunnel

Typical Elevated Floor Level

Area 1

Elevated Floor Level Area 1


7 composite slab (4 N.W. concrete topping + 3-18ga composite metal deck)

Typical Column Splice Details

Typical Slab Reinforcing at Girder

Typical Slab Reinforcing at Edge

Typical Slab Edge Bent Plate Detail

Typical Slab Edge Bent Plate Detail

Slab Reinforcement at Columns

Brick Relief Angle Bracket

Roof Level

Area 1

Roof Level Area 1

3-18ga galvanized metal roof deck

Transition Detail Slab to Roof

Fall Protection