Handover is a basic function of the cellular mobile network. The purpose of handover is to ensure that a UE in CELL_DCH state is served continuously when it moves. With the development of WCDMA network, more and more users join in the system. Using Handover can achieve load balance between carriers and fully utilizes system resources. HCS: Hierarchical Cell Structure.
Course Name
N-2
Course Name
N-3
Course Name
N-4
Course Name
N-5
Active set: A set of cells simultaneously involved in a specific communication service between the UE and the UTRAN. Monitored set: A set of cells included in the CELL_INFO_LIST, but do not belong to the active set. Detected set: A set of cells detected by the UE, and do not included in the CELL_INFO_LIST. RL: Radio link between NodeB and UE. RLS: All radio links from the same NodeB consist of a radio link set. Combination way: For soft handover, the uplink signals are combined in RNC. The RNC will select one best signal to process. We call this selective combination. For softer handover, the uplink signals are combined in the RAKE receiver of NodeB. It is maximum ratio combination. Soft handover gain: Please refer to the WCDMA Coverage Planning course. PCPICH: Primary Common Pilot Channel. UE measures the signal strength of PCPICH for handover decision.
Course Name
N-6
Course Name
N-7
Course Name
N-8
Course Name
N-9
Intra-frequency handover is of the following two types: Intra-frequency soft handover: means that multiple radio links are connected to the UE at the same time. Intra-frequency hard handover: means that only one radio link is connected to the UE at the same time.
Course Name
N-10
The maximum number of RL in the active set is 3 by default. And This parameter can be changed in the RNC. But this function need the UE to support. Normally, the active set supported by UE is fixed 3 and can not be changed.
Course Name
N-11
Intra-frequency soft handover is characterized by the function that the UE can be connected to multiple Universal Terrestrial Radio Access Network (UTRAN) access points at the same time. Addition and/or release of radio links are controlled by the ACTIVE SET UPDATE procedure. The HO_INTRA_FREQ_SOFT_HO_SWITCH parameter in the SET CORRMALGOSWITCH command is used to determine whether to enable both soft handover and softer handover. By default, this switch is set to ON, indicating that both soft handover and softer handover are enabled.
Course Name
N-12
During softer handover, the uplink signaling are combined in NodeB by maximum ratio combination, but during soft handover they are combined in RNC by selective combination. Compare to later one, the maximum ratio combination can get more gain. So the performance of maximum ratio combination is better. Since softer handover is completed in NodeB, it do not consume more transport resource of Iub. In telecommunications, maximal-ratio combining is a method of diversity combining in which: (a) the signals from each channel are added together, (b) the gain of each channel is made proportional to the rms signal level and inversely proportional to the mean square noise level in that channel. (c) different proportionality constants are used for each channel. It is also known as ratio-squared combining and combining. Maximal-ratio-combining is the optimum combiner for independent AWGN channels.
Course Name
N-13
Compared with soft handover, intra-frequency hard handover uses fewer resources. The scenarios of intra-frequency hard handover are as follows: No Iur interface is present between RNCs. In this scenario, intrafrequency hard handover instead of soft handover can be performed between two RNCs. The Iur interface is congested between RNCs. In this scenario, also intra-frequency hard handover instead of soft handover can be performed between two RNCs. There is a high-speed Best Effort (BE) service. Compared with soft handover, intra-frequency hard handover is used to save downlink bandwidth for a high-speed BE service. The intra-frequency soft handover fails and intra-frequency hard handover is allowed. When intra-frequency soft handover fails because of a congestion problem of the target cell, the RNC tries an intrafrequency hard handover with a lower service bit rate. The HO_INTRA_FREQ_HARD_HO_SWITCH parameter in the SET CORRMALGOSWITCH command is used to determine whether to enable intrafrequency hard handover. By default, this switch is set to ON.
Course Name
N-14
Course Name
N-15
The intra-frequency handover procedure is divided into three phases: handover measurement, handover decision, and handover execution. After the UE transits to the CELL_DCH state in connected mode during a call, the RNC sends a MEASUREMENT CONTROL message to instruct the UE to take measurements and report the measurement event results. Upon the reception of an event report from the UE, the RNC makes a handover decision and performs the corresponding handover.
Course Name
N-16
Course Name
N-17
The MEASUREMENT CONTROL message carries the following information: Event trigger threshold Hysteresis value Event trigger delay time Neighboring cell list
Course Name
N-18
Course Name
N-19
Course Name
N-20
MNew is the measurement value of the cell in the reporting range. CIONew is equal to the sum of CIO and CIOOffset, which adjusts the cell boundary in the handover algorithms. To facilitate handover in neighboring cell configuration, the parameter is set as a positive value; otherwise, the parameter is set as a negative value. W represents Weighted factor, which is determined by the parameter Weight. The total quality of the best cell and the active set is specified by W. Mi is the measurement value of a cell in the active set. NA is the number of cells not forbidden to affect the reporting range in the active set. The parameter CellsForbidden1A indicates whether adding the cell to the active set affects the relative threshold of event 1A. MBest is the measurement value of the best cell in the active set. R1a is the reporting range or the relative threshold of soft handover. The threshold parameters of the CS non-VP service, VP service, and PS service are as follows: IntraRelThdFor1ACSVP IntraRelThdFor1ACSNVP IntraRelThdFor1APS H1a represents 1A hysteresis, the hysteresis value of event 1A.
Course Name
N-21
The above figure shows the triggering of event 1A. In this procedure, the default parameter values are used. If the signal quality of a cell that is not in the active set is higher than Th1A for a period of time specified by TrigTime1A (that is, Time to trigger in the figure), the UE reports event 1A. Th1A = (CPICH Ec/No of the best cell in the active set) - (reporting range for event 1A) If Weighted factor > 0, then Th1A = (general signal quality of all the cells in the active set) - (reporting range for event 1A). Reporting range for event 1A is equal to the value of IntraRelThdFor1ACSVP, IntraRelThdFor1ACSNVP, or IntraRelThdFor1APS.
Course Name
N-22
CIO
Content: This parameter works with the Neighboring cell oriented CIO. It is used for intra- or inter-frequency handover decisions. The larger the sum, the higher the handover priority of the neighboring cell. The smaller the sum, the lower the handover priority of the neighboring cell. Usually it is configured to 0. Value range: -20~20 Physical value range: -10~10; step: 0.5 Physical unit: dB
Set this parameter through ADD CELLSETUP/MOD CELLSETUP. CIOOffset Content: This parameter defines the neighboring cell oriented cell individual offset. The set value functions in combination of the cell oriented CIO. Their sum is added to the measurement quantity before the UE evaluates whether an event has occurred. In handover algorithms, this parameter is used for moving the border of a cell. Value range: -20~20
Physical value range: -20~20; step: 1 Physical unit: dB Set this parameter through ADD INTRAFREQNCELL/MOD INTRAFREQNCELL.
Course Name
N-23
IntraRelThdFor1ACSNVP/IntraRelThdFor1ACSVP/IntraRelThdFor1APS
Content: These parameters specify the CS non-VP/VP and PS services relative threshold of event 1A. The higher the threshold is, the more easily the target cell joins the active set, the harder the call drops, the larger the ratio of the UE involved in soft handover is, but the more the use of forward resources is. The lower the threshold is, the more difficult the target cell joins the active set. Thus the communication quality and the smooth handover cannot be guaranteed. Value range: 0~29 Physical value range: 0~14.5; step: 0.5 Physical unit: dB
Course Name
N-24
Hystfor1A
Content: This parameter specifies the hysteresis value for event 1A. The value of this parameter correlates with slow fading. The larger the value of this parameter, the less possibility of ping-pong effect or wrong decision. But the event might not be triggered in time. Value range: 0~15 Physical value range: 0~7.5; step: 0.5 Physical unit: dB Content: This parameter specifies the time delay to trigger event 1A. The value of this parameter correlates with slow fading. The larger the value of this parameter, the lower the incorrect decision probability, but the slower the response of the event to measurement signal change. Value range: D0, D10, D20, D40, D60, D80, D100, D120, D160, D200, D240, D320, D640, D1280, D2560, D5000 Physical value range: 0, 10, 20, 40, 60, 80, 100, 120, 160, 200, 240, 320, 640, 1280, 2560, 5000 Physical unit: ms Content: This parameter is used to define the soft handover relative threshold based on the measured value of each cell in the active set. The greater the parameter value, the higher the soft handover relative threshold. When this value is set to 0, the soft handover relative threshold is determined only by the best cell in the active set. Value range: 0~20 Physical value range: 0~2; step: 0.1
TrigTime1A
Weight
Course Name
N-25
The report mode of 1A is event trigger report. Generally the event 1A is reported only once. However, to avoid measurement report loss, the event 1A reporting can be turned to periodical reporting.
Course Name
N-26
ReportIntervalfor1A Content: This parameter specifies the reporting period of event 1A. That is, event 1A is reported at each reporting interval. Usually, event 1A is reported only once. Nevertheless, if the cell, where event 1A is reported, does not join the active set in a specified period of time, the UE can change the reporting of event 1A into periodical mode to avoid missing of measurement reports. The event 1A of this cell is reported for PeriodMRReportNumfor1A times with the reporting interval as the set value. Value range: NON_PERIODIC_REPORT, D250, D500, D1000, D2000, D4000, D8000, D16000 Physical value range: NON_PERIODIC_REPORT, 250, 500, 1000, 2000, 4000, 8000, 16000 Physical unit: ms PeriodMRReportNumfor1A Content: This parameter specifies the number of reporting times of event 1A for periodical reporting. When the actual reporting times exceeds the set value, the periodical reporting ends. Value range: D1, D2, D4, D8, D16, D32, D64, INFINITY Physical value range: 1, 2, 4, 8, 16, 32, 64, INFINITY Set these parameters through SET INTRAFREQHO/ADD CELLINTRAFREQHO/MOD CELLINTRAFREQHO.
Course Name
N-27
MOld is the measurement value of the cell that becomes worse. CIOOld is equal to the sum of CIO and CIOOffset, which is the offset between the cell in the reporting range and the best cell in the active set. W represents Weighted factor, used to weight the quality of the active set. The total quality of the best cell and the active set is specified by the parameter Weight. Mi is the measurement value of a cell in the active set. NB is the number of cells not forbidden to affect the reporting range in the active set. The parameter CellsForbidden1B indicates whether adding the cell to the active set affects the relative threshold of event 1B. MBest is the measurement value of the best cell in the active set. R1b is the reporting range or the relative threshold of soft handover. The threshold parameters of the CS non-VP service, VP service, and PS services are as follows: IntraRelThdFor1BCSVP IntraRelThdFor1BCSNVP IntraRelThdFor1BPS H1b is the hysteresis value of event 1B, which is determined by the parameter Hystfor1B.
Course Name
N-28
The above figure shows the triggering of event 1B. In this procedure, the default parameter values are used. If the signal quality of a cell in the active set is lower than Th1B for a period of time specified by TrigTime1B (Time to trigger in the figure), the UE reports event 1B. Th1B = (CPICH Ec/No of the best cell in the active set) - (reporting range for event 1B) If Weight > 0, then Th1B = (general signal quality of all the cells in the active set) - (reporting range for event 1B). Reporting range for event 1B is equal to the value of IntraRelThdFor1BCSVP, IntraRelThdFor1BCSNVP, or IntraRelThdFor1BPS. Configuration rule and restriction: The value of IntraRelThdFor1BCSNVP has to be larger than that of IntraRelThdFor1ACSNVP. The value of IntraRelThdFor1BCSVP has to be larger than that of IntraRelThdFor1ACSVP. The value of IntraRelThdFor1BPS has to be larger than that of IntraRelThdFor1APS.
Course Name
N-29
IntraRelThdFor1BCSNVP/IntraRelThdFor1BCSVP/IntraRelThdFor1BPS
Content: These parameters specify the CS non-VP/VP and PS services relative threshold of event 1B. The lower the threshold is, the more easily the event 1B is triggered. The higher the threshold is, the harder the event 1B is triggered. Value range: 0~29 Physical value range: 0~14.5; step: 0.5 Physical unit: dB
Course Name
N-30
Hystfor1B Content: This parameter specifies the hysteresis value for event 1B. The value of this parameter correlates with slow fading. The larger the value of this parameter, the less possibility of ping-pong effect or wrong decision. But the event might not be triggered in time. Value range: 0~15 Physical value range: 0~7.5; step: 0.5 Physical unit: dB TrigTime1B Content: This parameter specifies the time delay to trigger event 1B. The value of this parameter correlates with slow fading. The larger the value of this parameter, the lower the incorrect decision probability, but the slower the response of the event to measurement signal change. Value range: D0, D10, D20, D40, D60, D80, D100, D120, D160, D200, D240, D320, D640, D1280, D2560, D5000 Physical value range: 0, 10, 20, 40, 60, 80, 100, 120, 160, 200, 240, 320, 640, 1280, 2560, 5000 Physical unit: ms Set these parameters through SET INTRAFREQHO/ADD CELLINTRAFREQHO/MOD CELLINTRAFREQHO.
Course Name
N-31
MNew is the measurement value of the cell in the reporting range. CIONew is the cell individual offset value of the cell in the reporting range. It is equal to the sum of CIO and CIOOffset, which is the offset between the cell in the reporting range and the best cell in the active set. MInAS is the measurement value of the worst cell in the active set. H1c is the hysteresis value of event 1C, which is determined by the parameter Hystfor1C.
Course Name
N-32
The above figure shows the triggering of event 1C. In this procedure, the default parameter values are used. If the signal quality of a cell not in the active set is higher than Th1C for a period of time specified by TrigTime1C (Time to trigger in the figure), the UE reports event 1C, as shown in the figure. Th1C = (CPICH Ec/No of the worst cell in the active set) + (Hystfor1C/2) The UE reports event 1C for qualified cells after the number of cells in the active set reaches the maximum value. The maximum number of cells in the active set can be set by the MaxCellInActiveSet parameter.
Course Name
N-33
Hystfor1C Content: This parameter specifies the hysteresis value for event 1C. The value of this parameter correlates with slow fading. The larger the value of this parameter, the less possibility of ping-pong effect or wrong decision. But the event might not be triggered in time. Value range: 0~15 Physical value range: 0~7.5; step: 0.5 Physical unit: dB TrigTime1C Content: This parameter specifies the time delay to trigger event 1C. The value of this parameter correlates with slow fading. The larger the value of this parameter, the lower the incorrect decision probability, but the slower the response of the event to measurement signal change. Value range: D0, D10, D20, D40, D60, D80, D100, D120, D160, D200, D240, D320, D640, D1280, D2560, D5000 Physical value range: 0, 10, 20, 40, 60, 80, 100, 120, 160, 200, 240, 320, 640, 1280, 2560, 5000 Physical unit: ms Set these parameters through SET INTRAFREQHO/ADD CELLINTRAFREQHO/MOD CELLINTRAFREQHO.
Course Name
N-34
The report mode of 1C is event trigger report. Generally the event 1C is reported only once. However, to avoid measurement report loss, the event 1C reporting can be turned to periodical reporting.
Course Name
N-35
ReportIntervalfor1C Content: This parameter specifies the number of reporting times of event 1C for periodical reporting. That is, event 1C is reported at each reporting interval. Usually, event 1C is reported only once. Nevertheless, if the cell, where event 1C is reported, does not join the active set in a specified period of time, the UE can change the reporting of event 1C into periodical mode to avoid missing of measurement reports. The event 1C of this cell is reported for PeriodMRReportNumfor1C times with the reporting interval as the set value. Value range: NON_PERIODIC_REPORT, D250, D500, D1000, D2000, D4000, D8000, D16000 Physical value range: NON_PERIODIC_REPORT, 250, 500, 1000, 2000, 4000, 8000, 16000 Physical unit: ms PeriodMRReportNumfor1C Content: This parameter specifies the number of reporting times of event 1C for periodical reporting. When the actual reporting times exceeds the set value, the periodical reporting ends. Value range: D1, D2, D4, D8, D16, D32, D64, INFINITY Physical value range: 1, 2, 4, 8, 16, 32, 64, INFINITY Set these parameters through SET INTRAFREQHO/ADD CELLINTRAFREQHO/MOD CELLINTRAFREQHO.
Course Name
N-36
MNotBest is the measurement value of a cell that is not the best cell. CIONotBest is equal to the sum of CIO and CIOOffset, which is the offset between the cell in the reporting range and the best cell in the active set. MBest is the measurement value of the best cell in the active set. CIOBest is the cell individual offset value of the best cell. This parameter is not used for event 1D. H1d is the hysteresis value of event 1D, which is determined by the parameter Hystfor1D.
Course Name
N-37
The above figure shows the triggering of event 1D. In this procedure, the default parameter values are used. If the signal quality of a cell not in the active set is higher than Th1D for a period of time specified by TrigTime1D (Time to trigger in the figure), the UE reports event 1D. Th1D = (CPICH Ec/No of the best cell in the active set) + (Hystfor1D/2)
Course Name
N-38
Hystfor1D Content: This parameter specifies the hysteresis value for event 1D. The value of this parameter correlates with slow fading. The larger the value of this parameter, the less possibility of ping-pong effect or wrong decision. But the event might not be triggered in time. Value range: 0~15 Physical value range: 0~7.5; step: 0.5 Physical unit: dB TrigTime1D Content: This parameter specifies the time delay to trigger event 1D. The value of this parameter correlates with slow fading. The larger the value of this parameter, the lower the incorrect decision probability, but the slower the response of the event to measurement signal change. Value range: D0, D10, D20, D40, D60, D80, D100, D120, D160, D200, D240, D320, D640, D1280, D2560, D5000 Physical value range: 0, 10, 20, 40, 60, 80, 100, 120, 160, 200, 240, 320, 640, 1280, 2560, 5000 Physical unit: ms Set these parameters through SET INTRAFREQHO/ADD CELLINTRAFREQHO/MOD CELLINTRAFREQHO.
Course Name
N-39
MNew is the measurement result of the cell not in the E-DCH active set but in the DCH active set. CIONew and CIOInAS refer to the offset of each cell. MInAS is the measurement result of the cell in the E-DCH active set with the lowest measurement result. H1J is the hysteresis parameter for event 1J and is determined by Hystfor1J.
Course Name
N-40
The above figure shows the triggering of event 1J. In this procedure, the hysteresis and the cell individual offsets for all cells equal 0. If the signal quality of a cell not in the E-DCH active set is higher than Th1J for a period of time specified by TrigTime1J (Time to trigger in the figure), the UE reports event 1J. Th1J = (CPICH Ec/No of the worst cell in the active set) + (Hystfor1J/2)
The first measurement report is sent when primary CPICH D becomes better than primary CPICH B. The "cell measurement event result" of the measurement report contains the information of primary CPICH D and CPICH B. On the assumption that the E-DCH active set has been updated after the first measurement report (E-DCH active set is now primary CPICH A and primary CPICH D), the second report is sent when primary CPICH C becomes better than primary CPICH A. The "cell measurement event result" of the second measurement report contains the information of primary CPICH C and primary CPICH A.
Course Name
N-41
3GPP define the maximum DCH active set size is 6 and the maximum E-DCH active set size is 4. The DCH active set covers the E-DCH active set or they are the same. The best cell in E-DCH active set should be the same as that in DCH active set. Uplink channel type of UE is decided by the best cell in DCH active set: Uplink channel is E-DCH if the best cell in DCH active set supports HSUPA. Uplink channel is DCH if the best cell in DCH active set can NOT support HSUPA. The UE reports 1J event if it find a non-active E-DCH but active DCH cell PCICH becomes better than an active E-DCH PCIPCH. RNC will add the target cell into E-DCH active set if the E-DCH active set is NOT full. RNC will perform replace procedure if the E-DCH active set is full.
Course Name
N-42
Hystfor1J Content: This parameter specifies the hysteresis value for event 1J. The value of this parameter correlates with slow fading. The larger the value of this parameter, the less possibility of ping-pong effect or wrong decision. But the event might not be triggered in time. Value range: 0~15 Physical value range: 0~7.5; step: 0.5 Physical unit: dB Set this parameter through SET INTRAFREQHO/ADD CELLINTRAFREQHO/MOD CELLINTRAFREQHO. TrigTime1J Content: This parameter specifies the time delay to trigger event 1J. The value of this parameter correlates with slow fading. The larger the value of this parameter, the lower probability of incorrect decision, but the slower the response of event to the change of measured signals. Value range: D0, D10, D20, D40, D60, D80, D100, D120, D160, D200, D240, D320, D640, D1280, D2560, D5000 Physical value range: 0, 10, 20, 40, 60, 80, 100, 120, 160, 200, 240, 320, 640, 1280, 2560, 5000 Physical unit: ms Set this parameter through SET INTRAFREQHO/ADD CELLINTRAFREQHO/MOD CELLINTRAFREQHO. MaxEdchCellInActiveSet Content: This parameter determines the maximum number of links in the EDCH active set. When the RNC acts as the SRNC, the number of links in the EDCH active set for all the UEs under the RNC cannot exceed the parameter value. If the parameter value is too large, a lot of resources on the RAN side will be occupied as the same data is transferred over multiple EDCH links in macro diversity, thus affecting the system performance. If this parameter value is too small, insufficient combination gain can be achieved in macro diversity by the EDCH, which causes excessive retransmissions and affects the UE speed. Value range: 1~4 Physical value range: 1~4; step: 1 Set this parameter throughof SET HOCOMM. Confidential Information Huawei. No Spreading Without Permission
Course Name
N-43
The report mode of 1J is event trigger report. Generally the event 1J is reported only once. However, to avoid measurement report loss, the event 1J reporting can be turned to periodical reporting.
Course Name
N-44
ReportIntervalfor1J Content: This parameter specifies the number of reporting times of event 1J for periodical reporting. That is, event 1J is reported at each reporting interval. Usually, event 1J is reported only once. Nevertheless, if the cell, where event 1J is reported, does not join the EDCH active set in a specified period of time, the UE can change the reporting of event 1J into periodical mode to avoid missing of measurement reports. The event 1J of this cell is reported for PeriodMRReportNumfor1J times with the reporting period as the set value. Value range: NON_PERIODIC_REPORT, D250, D500, D1000, D2000, D4000, D8000, D16000 Physical value range: NON_PERIODIC_REPORT, 250, 500, 1000, 2000, 4000, 8000, 16000 Physical unit: ms PeriodMRReportNumfor1J Content: This parameter specifies the number of reporting times of event 1J for periodical reporting. When the actual reporting times exceeds the set value, the periodical reporting ends. Value range: D1, D2, D4, D8, D16, D32, D64, INFINITY Physical value range: 1, 2, 4, 8, 16, 32, 64, INFINITY Set these parameters through SET INTRAFREQHO/ADD CELLINTRAFREQHO/MOD CELLINTRAFREQHO.
Course Name
N-45
Course Name
N-46
Event
Decision and Execution When receiving an event 1A report, the RNC decides whether to add a cell. For event 1A, the UE can report more than one cell in the event list in one measurement report. These cells are in the list of the MEASUREMENT CONTROL message, and they are sequenced in descending order of measurement quantity. For the cells in the list, the RNC adds the radio link to the active set only if the number of cells in the active set does not reach the maximum value. This operation is not required if the number of cells in the active set reaches a specified value. When receiving an event 1B report, the RNC decides whether to delete a cell. For event 1B, if there is more than one radio link in the active set, the RNC decides whether to delete a radio link. This operation is not required if there is only one radio link in the active set. When receiving an event 1C report, the RNC decides whether to change the worst cell. For event 1C, the UE reports a list that contains good cells and the cells to be replaced, and sequences the cells in descending order by measurement quantity. After receiving the list from the UE, the RNC replaces the bad cells in the active set with the good cells in the list.
1A
1B
1C
Course Name
N-47
MaxCellInActiveSet Content: This parameter specifies the maximum number of cells in the active set. This parameter can achieve the balance between the signal quality in the SHO area and the performance of the system. The more cells the active set contains, the larger macro diversity gain the user obtains in the SHO area, and the smaller the intra-frequency interference is. But in this case, the user occupies resources of several cells, which increases the amount of data to be processed by the system and lowers the system performance. Value range: 1~6 Physical value range: 1~6; step: 1 SHOQualmin Content: When the RNC receives events 1A, 1C and 1D, the target cell can be added to the active set only when CPICH Ec/No of the target cell is higher than this absolute threshold. Value range: -24~0 Physical value range: -24~0; step: 1 Physical unit: dB Set these parameters through SET INTRAFREQHO/ADD CELLINTRAFREQHO/MOD CELLINTRAFREQHO.
Course Name
N-48
Course Name
N-49
After the active set is updated, the RNC updates the neighboring cell list by using the neighboring cell combination algorithm according to the status of the active set. This list includes the new intra-frequency, inter-frequency, and interRAT neighboring cells. The combination methods of intra-frequency handover, inter-frequency handover, and inter-RAT handover are the same. The neighboring cell combination result is contained in the MEASUREMENT CONTROL message and sent to the UE, which instructs the UE to perform intra-frequency, inter-frequency, and inter-RAT measurement and handover procedures. The number of inter-frequency neighboring cells is configured as follows: A maximum of 32 intra-frequency neighboring cells are configured. A maximum of 32 single-carrier inter-frequency neighboring cells are configured. A maximum of 64 multi-carrier inter-frequency neighboring cells are configured. A maximum of 32 inter-RAT neighboring cells are configured.
Course Name
N-50
Neighboring cell combination switch: HO_MC_NCELL_COMBINE_SWITCH is the neighboring cell combination switch. If the switch is set to ON, measurement objects are chosen from the neighboring cells of all the cells in the active set. If the switch is set to OFF, measurement objects are chosen from the neighboring cells of the best cell. Neighboring cell combination procedure: After obtaining the intra-frequency neighboring cells of each cell in the active set, the RNC calculates the union neighboring cell set of the intra-frequency cells, which is referred as Sall, by using the following method. This method can also be used to generate the Sall of inter-frequency or inter-RAT cells. The intra-frequency, inter-frequency, and inter-RAT neighboring cells of each cell in the current active set are obtained. The RNC sequences the cells in the active set in descending order of CPICH Ec/No according to the latest measurement report (event 1A, 1B, 1C, or 1D) from the UE. The best cell is based on event 1D, whereas other cells are based on the latest measurement report. The cells in the active set are added to Sall. The neighboring cells of the best cell in the active set are added to Sall. NprioFlag (the flag of the priority) and Nprio (the priority of the neighboring cell), which are set for each neighboring cell, are used to change the order of adding the neighboring cells to Sall. The neighboring cells of other cells in the active set are added to Sall in descending order by CPICH Ec/No values of these cells in the active set. The neighboring cells of the same cell in the active set are added according to Nprio and the number of repeated neighboring cell is recorded. If there are more than 32 intra-frequency neighboring cells in Sall, delete the repeated neighboring cells whose number in Sall is less. The top 32 neighboring cells are grouped into the final Sall.
Course Name
N-51
HO_MC_NCELL_COMBINE_SWITCH Content: When the switch is on, the neighboring cell combined algorithm is used during the delivery of the objects to be measured. When the switch is off, the best cell algorithm is used. Value range: ON, OFF Physical value range: 1, 0 Set this parameter through SET CORRMALGOSWITCH. NprioFlag Content: Priority identifier of neighboring cells. TRUE indicates that the neighboring cell priority is valid in the algorithm of neighboring cell combination. FALSE indicates that the neighboring cell priority is invalid, and, in the algorithm of neighboring cell combination, the cell with invalid priority is the last one to be considered as the measurement object. Value range: FALSE, TRUE Physical value range: FALSE, TRUE Nprio Content: Priority of neighboring cells. The lower the priority, the easier it is for the neighboring cell to be delivered as the measurement object. For example, it is more possible for a neighboring cell of priority 1 than a cell of priority 2 to be delivered as the measurement object. Value range: 0~30 Physical value range: 0~30; step: 1 Set the upper two parameters through ADD INTRAFREQNCELL/MOD INTRAFREQNCELL / ADD INTERFREQNCELL/MOD INTERFREQNCELL / ADD GSMNCELL/MOD GSMNCELL.
Course Name
N-52
Course Name
N-53
Course Name
N-54
Course Name
N-55
Course Name
N-56
Course Name
N-57
Course Name
N-58
Course Name
N-59
Course Name
N-60
Course Name
N-61
Coverage-based inter-frequency handover: If a moving UE leaves the coverage of the current frequency, the RNC needs to trigger the coverage-based inter-frequency handover to avoid call drops. QoS-based inter-frequency handover: According to the Link Stability Control Algorithm, the RNC needs to trigger the QoS-based inter-frequency handover to avoid call drops. Load-based inter-frequency blind handover: To balance the load between inter-frequency con-coverage cells, the RNC chooses some UEs and performs the inter-frequency blind handover according to user priorities and service priorities. Speed-based inter-frequency handover: When the Hierarchical Cell Structure (HCS) applies, the cells are divided into different layers according to coverage. The macro cell has a larger coverage and a lower priority, whereas the micro cell has a smaller coverage and a higher priority. Inter-frequency handover can be triggered by the UE speed estimation algorithm of the HCS. To reduce frequent handovers, the UE at a higher speed is handed over to a cell under a larger coverage, whereas the UE at a lower speed is handed over to a cell under a smaller coverage. The InterFreqHOSwitch parameter in the ADD CELLHOCOMM command is used to chooses the inter-frequency measurement control parameters to implement handover measurement based on coverage, QoS and speed. The HO_INTER_FREQ_HARD_HO_SWITCH parameter in the SET CORRMALGOSWITCH command is used to determine whether to allow loadConfidential Information of Huawei. No Spreading Without Permission based inter-frequency handover.
Course Name
N-62
Course Name
N-63
In the triggering phase: The RNC requests the UE to measure through an inter-frequency measurement control message. If the CPICH Ec/No or CPICH RSCP of the current cell is lower than the corresponding threshold, the UE reports event 2D. In the measurement phase: The RNC sends an inter-frequency measurement control message to the UE, requesting the NodeB and UE to start the compressed mode. The RNC also requests the UE to perform the inter-frequency measurement. In this phase, the method of either periodical measurement report or event-triggered measurement report can be used. In the decision phase: After the UE reports event 2B, the RNC performs the handover. Otherwise, the UE periodically generates measurement reports, and the RNC makes a decision after evaluation. In the execution phase: The RNC executes the handover procedure.
Course Name
N-64
When the estimated quality or strength of the currently used frequency is below a certain threshold, 2D event will be triggered. Then RNC will initiate the compressed mode to start inter-frequency measurement. During compressed mode, if the estimated quality of the currently used frequency is above a certain threshold, 2F event will be triggered. Then RNC will stop the compressed mode.
Course Name
N-65
Compressed mode control is a mechanism whereby certain idle periods are created in radio frames during which the UE can perform measurements on other frequencies. The UE can carry out measurements in the neighboring cell, such as GSM cell and FDD cell on other frequency. If the UE needs to measure the pilot signal strength of an inter-frequency WCDMA or GSM cell and has one frequency receiver only, the UE must use the compressed mode. Each physical frame can provide 3 to 7 timeslots for the inter-frequency or interRAT cell measurement, which enhances the transmit capability of physical channels but reduces the volume of data traffic. In DL, during compressed mode, UE receiver can test signal from other frequency. In order to avoid the effect cause by UE transmitter, compressed mode is also used in UL. The compressed mode includes two types, spreading factor reduction (SF/2) and high layer approaches. The usage of type of compressed mode is decided by the RNC, according to spreading factor used in uplink or downlink.
Course Name
N-66
QUsed is the measured quality of the used frequency. TUsed2d is the absolute quality threshold of the cell that uses the current frequency. Based on the service type and measurement quantity, this threshold can be configured through one of the following parameters: InterFreqCSThd2DEcN0 InterFreqR99PsThd2DEcN0 InterFreqHThd2DEcN0 InterFreqCSThd2DRSCP InterFreqR99PsThd2DRSCP InterFreqHThd2DRSCP H2d is the event 2D hysteresis value set through the parameter HystFor2D. After the conditions of event 2D are fulfilled and maintained until the TimeToTrig2D is reached, the UE sends the event 2D measurement report message.
Any of the Ec/No and RSCP measurement result can trigger the 2D event.
Course Name
N-67
InterFreqCSThd2DEcN0 Content: Threshold to trigger inter-frequency measurement with measurement quantity of Ec/No for CS domain services. Value range: -24~0 Physical value range: -24~0; step: 1 Physical unit: dB InterFreqR99PsThd2DEcN0 Content: Threshold to trigger inter-frequency measurement with measurement quantity of Ec/No for PS domain non-HSPA services. Value range: -24~0 Physical value range: -24~0; step: 1 Physical unit: dB InterFreqHThd2DEcN0 Content: Threshold to trigger inter-frequency measurement with measurement quantity of Ec/No for PS domain HSPA services. Value range: -24~0 Physical value range: -24~0; step : 1 Physical unit: dB Set these parameters through ADD CELLINTERFREQHOCOV/MOD CELLINTERFREQHOCOV/SET INTERFREQHOCOV.
Course Name
N-68
InterFreqCSThd2DRSCP
Content: Threshold to trigger inter-frequency measurement with measurement quantity of RSCP for CS domain services.
InterFreqR99PsThd2DRSCP
InterFreqHThd2DRSCP
Physical unit: dBm Set these parameters through ADD CELLINTERFREQHOCOV/MOD CELLINTERFREQHOCOV/SET INTERFREQHOCOV.
Course Name
N-69
HystFor2D Content: Hysteresis value for the event 2D. The value of this parameter correlates with slow fading. The larger the value of this parameter, the smaller probability of ping-pong effect or wrong decision, but event 2D might not be triggered in time. Value range: 0~29 Physical value range: 0~14.5; step: 0.5 Physical unit: dB TimeToTrig2D Content: Time delay to trigger event 2D. The value of this parameter correlates with slow fading. The larger the value of this parameter, the lower probability of incorrect decision, but the slower the response of event 2D to the change of measured signals. Value range: D0, D10, D20, D40, D60, D80, D100, D120, D160, D200, D240, D320, D640, D1280, D2560, D5000 Physical value range: 0, 10, 20, 40, 60, 80, 100, 120, 160, 200, 240, 320, 640, 1280, 2560, 5000 Physical unit: ms Set these parameters through ADD CELLINTERFREQHOCOV/MOD CELLINTERFREQHOCOV/SET INTERFREQHOCOV.
Course Name
N-70
QUsed is the measured quality of the used frequency. TUsed2f is the absolute quality threshold of the cell that uses the current frequency. Based on the service type and measurement quantity, this threshold can be configured through one of the following parameters: InterFreqCSThd2FEcN0 InterFreqR99PsThd2FEcN0 InterFreqHThd2FEcN0 InterFreqCSThd2FRSCP InterFreqR99PsThd2FRSCP InterFreqHThd2FRSCP H2f is the event 2F hysteresis value set through the parameter HystFor2F. After the conditions of event 2F are fulfilled and maintained until the parameter TimeToTrig2F is reached, the UE reports the event 2F measurement report message. Any of Ec/No and RSCP measurement result can trigger the 2F event. Conditions of event 2F are as follows: TUsed2d - H2d/2 < TUsed2f + H2f/2, for example, (InterFreqCSThd2DEcN0HystFor2D/2) < (InterFreqCSThd2FEcN0+ HystFor2F/2).
Course Name
N-71
InterFreqCSThd2FEcN0 Content: Threshold to stop inter-frequency measurement with measurement quantity of Ec/No for CS domain services. Value range: -24~0 Physical value range: -24~0; step: 1 Physical unit: dB InterFreqR99PsThd2FEcN0 Content: Threshold to stop inter-frequency measurement with measurement quantity of Ec/No for PS domain non-HSPA services. Value range: -24~0 Physical value range: -24~0; step: 1 Physical unit: dB InterFreqHThd2FEcN0 Content: Threshold to stop inter-frequency measurement with measurement quantity of Ec/No for PS domain HSPA services. Value range: -24~0 Physical value range: -24~0; step: 1 Physical unit: dB Set these parameters through ADD CELLINTERFREQHOCOV/MOD CELLINTERFREQHOCOV/SET INTERFREQHOCOV.
Course Name
N-72
InterFreqCSThd2FRSCP
Content: Threshold to stop inter-frequency measurement with measurement quantity of RSCP for CS domain services.
InterFreqR99PsThd2FRSCP
InterFreqHThd2FRSCP
Physical unit: dBm Set these parameters through ADD CELLINTERFREQHOCOV/MOD CELLINTERFREQHOCOV/SET INTERFREQHOCOV.
Course Name
N-73
HystFor2F Content: Hysteresis value for the event 2F. The value of this parameter correlates with slow fading. The larger the value of this parameter, the smaller probability of ping-pong effect or wrong decision, but event 2F might not be triggered in time. Value range: 0~29 Physical value range: 0~14.5; step: 0.5 Physical unit: dB TimeToTrig2F Content: Time delay to trigger the event 2F. The value of this parameter correlates with slow fading. The larger the value of this parameter, the lower probability of incorrect decision, but the slower the response of event 2F to the change of measured signals. Value range: D0, D10, D20, D40, D60, D80, D100, D120, D160, D200, D240, D320, D640, D1280, D2560, D5000 Physical value range: 0, 10, 20, 40, 60, 80, 100, 120, 160, 200, 240, 320, 640, 1280, 2560, 5000 Physical unit: ms Set these parameters through ADD CELLINTERFREQHOCOV/MOD CELLINTERFREQHOCOV/SET INTERFREQHOCOV.
Course Name
N-74
When the UE enters the compress mode, RNC will trigger the inter-frequency handover measurement by two additional measurement control signaling, so as to request UE test inter-frequency neighbor cell. In this Measurement control message, RNC should inform the UE interfrequency measurement parameter, including neighbor list and reporting mode as well.
Course Name
N-75
The measurement report mode of inter-frequency handover is configured through the parameter InterFreqReportMode. By default, periodically reporting is recommended. The advantage of periodical measurement report is that if the handover fails, the RNC reattempts the handover to the same cell after receiving the periodical measurement report from the UE. This increases the probability of the success of inter-frequency handover. Based on the measurement control message received from the RNC, the UE periodically reports the measurement quality of the target cell. Then, based on the measurement report, the RNC makes the handover decision and performs handover. If the reporting mode is periodically reporting: UE test the Inter-frequency neighbor RSCP and Ec/No. If the reporting mode is event trigger reporting: UE test the Inter-frequency neighbor RSCP and Ec/No, and current cell Ec/No or RSCP.
Course Name
N-76
InterFreqReportMode
Content: This parameter specifies the inter-frequency measurement report mode. Value range: PERIODICAL_REPORTING(Periodical reporting), EVENT_TRIGGER(Event trigger)
Content: This parameter specifies the interval of the inter-frequency measurement report. Value range: NON_PERIODIC_REPORT(Non periodical reporting), D250, D500, D1000, D2000, D3000, D4000, D6000, D8000, D12000, D16000, D20000, D24000, D28000, D32000, D64000 Physical value range: NON_PERIODIC_REPORT, 250, 500, 1000, 2000, 3000, 4000, 6000, 8000, 12000, 16000, 20000, 24000, 28000, 32000, 64000 Physical unit: ms Content: Timer length for inter-frequency measurement. After inter-frequency measurement starts, if no inter-frequency handover is performed when this timer expires, the inter-frequency measurement and the compressed mode (if started) are stopped. The value 0 indicates the timer is not to be enabled. Value range: 0~512 Physical value range: 0~512; step: 1
InterFreqMeasTime
Physical unit: s Set these parameters through ADD CELLINTERFREQHOCOV/MOD CELLINTERFREQHOCOV/SET INTERFREQHOCOV.
Course Name
N-77
Course Name
N-78
Mother_Freq is the CPICH Ec/No or CPICH RSCP measurement value of the target cell reported by the UE. Both of the two measurement values of the interfrequency cell must satisfy the formula. CIOother_Freq is the cell individual offset value of the target cell. It is equal to the sum of CIO and CIOOffset. Tother_Freq is the decision threshold of inter-frequency hard handover. Based on the service type and measurement quantity, this threshold can be configured through one of the following parameters: TargetFreqCsThdEcN0 TargetFreqR99PsThdEcN0 TargetFreqHThdEcN0 TargetFreqCsThdRscp TargetFreqR99PsThdRscp TargetFreqHThdRscp These thresholds are the same as the quality threshold of event 2B. H is the inter-frequency hard handover hysteresis value set through the parameter HystForPrdInterFreq.
Course Name
N-79
Each cell in the measurement report shall be evaluated as mentioned previously. When the hard handover time-to-trigger timers of more than one cell expire at the same time, the latest measurement report is used for selecting the best inter-frequency neighboring cell for handover. For example, the cell with the highest CPICH RSCP in the latest measurement report is selected, as shown in the above figure.
Course Name
N-80
CIO
Content: This parameter works with the Neighboring cell oriented CIO. It is used for intra- or inter-frequency handover decisions. The larger the sum, the higher the handover priority of the neighboring cell. The smaller the sum, the lower the handover priority of the neighboring cell. Usually it is configured to 0. Value range: -20~20 Physical value range: -10~10; step: 0.5 Physical unit: dB
Set this parameter through ADD CELLSETUP/MOD CELLSETUP. CIOOffset Content: This parameter defines the neighboring cell oriented cell individual offset. The set value functions in combination of the cell oriented CIO. Their sum is added to the measurement quantity before the UE evaluates whether an event has occurred. In handover algorithms, this parameter is used for moving the border of a cell. Value range: -20~20
Physical value range: -20~20; step: 1 Physical unit: dB Set this parameter through ADD INTERFREQNCELL/MOD INTERFREQNCELL.
Course Name
N-81
HystForPrdInterFreq
Content: Hysteresis for inter-frequency hard handover in periodical report mode. This parameter is used to estimate the inter-frequency handover at the RNC. The larger the value of this parameter, the stronger the capability of resisting signal fluctuation. Thus, the ping-pong effect can be resisted, but the speed of the handover algorithm to respond to signal change becomes lower, and therefore event 2B might not be triggered in time. Value range: 0~29 Physical value range: 0~14.5; step: 0.5 Physical unit: dB Content: Hysteresis for inter-frequency hard handover in periodical report mode. This parameter is used to estimate the inter-frequency handover at the RNC. The larger the value of this parameter, the stronger the capability of resisting signal fluctuation. Thus, the ping-pong effect can be resisted, but the speed of the handover algorithm to respond to signal change becomes lower, and therefore event 2B might not be triggered in time. Value range: 0~64000 Physical value range: 0~64000; step: 1
TimeToTrigForPrdInterFreq
Physical unit: ms Set these parameters through ADD CELLINTERFREQHOCOV/MOD CELLINTERFREQHOCOV/SET INTERFREQHOCOV.
Confidential Information of Huawei. No Spreading Without Permission
Course Name
N-82
Course Name
N-83
QNoused is the measured quality of the cell that uses the other frequencies. QUsed is the measured quality of the used frequency. H2b is the event 2B hysteresis value set through the parameter HystFor2B. TNoused2b is the absolute quality threshold of the cell that uses the other frequencies. Based on the service type and measurement quantity, this threshold can be configured through one of the following parameters: TargetFreqCsThdEcN0 TargetFreqR99PsThdEcN0 TargetFreqHThdEcN0 TargetFreqCsThdRscp TargetFreqR99PsThdRscp TargetFreqHThdRscp TUsed2b is the absolute quality threshold of the cell that uses the current frequency. After the conditions of event 2B are fulfilled and maintained until the parameter TimeToTrig2B is reached, the UE reports the event 2B measurement report message.
Course Name
N-84
TUsed2b is set in the following way: Based on the service type and measurement quantity, this threshold can be configured through one of the following parameters: If event 2D with the CPICH RSCP value is received by the RNC:
TUsed2b of event 2B with the CPICH RSCP value can be: UsedFreqCSThdRSCP UsedFreqR99PsThdRSCP
UsedFreqHThdRSCP
TUsed2b of event 2B with the CPICH Ec/No value is configured as the maximum value 0dB.
According to 3GPP specifications, TUsed2b of event 2B with the CPICH Ec/No value should be configured as the maximum value 0dB. If the event 2F with the CPICH Ec/No value is received by the RNC and TUsed2b of event 2B with the CPICH Ec/No value is modified, TUsed2b is reset to 0dB. If event 2D with the CPICH Ec/No value is received by the RNC:
TUsed2b of event 2B with the CPICH Ec/No value can be: UsedFreqCSThdEcN0 UsedFreqR99PsThdEcN0 UsedFreqHThdEcN0
TUsed2b of event 2B with the CPICH RSCP value is configured as the maximum value 25 dBm. According to 3GPP specification, TUsed2b of event 2B with the CPICH RSCP value should be configured as the maximum value -25dBm. If event 2F with the CPICH RSCP value is received by the RNC and TUsed2b of event 2B with the CPICH RSCP value is modified, TUsed2b is reset to -25 dBm.
Course Name
N-85
TargetFreqCsThdEcN0 Content: Threshold of the target frequency for triggering inter-frequency measurement with measurement quantity of Ec/No for CS domain services. For CS domain services, if the value of inter-frequency measure report mode is set to EVENT_TRIGGER, this parameter is used to set the measurement control of event 2B. One of the necessary conditions for triggering event 2B can be met only when the quality of the target frequency is higher than this threshold. If the value of interfrequency measure report mode is set to PERIODICAL_REPORTING, this parameter is used to evaluate inter-frequency handovers at the RNC. . Value range: -24~0 Physical value range: -24~0; step: 1 Physical unit: dB UsedFreqCSThdEcN0 Content: Threshold of used frequency quality for triggering interfrequency measurement with measurement quantity of Ec/No for CS domain services. For CS domain services, if the value of inter-frequency measure report mode is set to EVENT_TRIGGER, this parameter is used to set the measurement control of event 2B. One of the necessary conditions can be met only when the quality of the used frequency is lower than this threshold. Value range: -24~0 Physical value range: -24~0; step: 1 Physical unit: dB Confidential Information ofADD Huawei. No Spreading Without Permission Set these parameters through CELLINTERFREQHOCOV/MOD CELLINTERFREQHOCOV/SET INTERFREQHOCOV.
Course Name
N-86
Course Name
N-87
HystFor2B Content: Hysteresis value for the event 2B. The value of this parameter correlates with slow fading. The larger the value of this parameter, the stronger the capability of resisting signal fluctuation. Thus, the ping-pong effect can be resisted, but the speed of the handover algorithm to respond to signal change becomes lower, and therefore event 2B might not be triggered in time. Value range: 0~29 Physical value range: 0~14.5; step: 0.5 Physical unit: dB TimeToTrig2B Content: Time delay to trigger event 2B. The value of this parameter correlates with slow fading. The larger the value of this parameter, the lower probability of incorrect decision, but the slower the response of event 2B to the change of measured signals. Value range: D0, D10, D20, D40, D60, D80, D100, D120, D160, D200, D240, D320, D640, D1280, D2560, D5000 Physical value range: 0, 10, 20, 40, 60, 80, 100, 120, 160, 200, 240, 320, 640, 1280, 2560, 5000 Physical unit: ms Set these parameters through ADD CELLINTERFREQHOCOV/MOD CELLINTERFREQHOCOV/SET INTERFREQHOCOV.
Course Name
N-88
InterFreqNCovHOThdEcN0
Content: Threshold of signal quality of the target frequency for triggering inter-frequency measurement. This parameter is used to set measurement control on the event 2C. The event 2C is triggered when the signal quality of the target frequency is above this threshold. Value range: -24~0 Physical value range: -24~0; step: 1 Physical unit: dB Content: Hysteresis value for the event 2C. The value of this parameter correlates with slow fading. The larger the value of this parameter, the stronger the capability of resisting signal fluctuation. Thus, the ping-pong effect can be resisted, but the speed of the handover algorithm to respond to signal change becomes lower, and therefore event 2C might not be triggered in time. Value range: 0~29 Physical value range: 0~14.5; step: 0.5 Physical unit: dB Content: Time delay to trigger the event 2C. The value of this parameter correlates with slow fading. The larger the value of this parameter, the lower probability of incorrect decision, but the slower the response of event 2C to the change of measured signals. . Value range D0, D10, D20, D40, D60, D80, D100, D120, D160, D200, D240, D320, D640, D1280, D2560, D5000 Physical value range: 0, 10, 20, 40, 60, 80, 100, 120, 160, 200, 240, 320, 640, 1280, 2560, 5000 Physical unit: ms
2C hysteresis
TrigTime2C
Set these parameters through ADD CELLINTERFREQHONCOV/MOD CELLINTERFREQHONCOV/SET INTERFREQHONCOV. Confidential Information of Huawei. No Spreading Without Permission
Course Name
N-89
Course Name
N-90
Course Name
N-91
Course Name
N-92
Course Name
N-93
Course Name
N-94
Inter-RAT handover refers to the handover performed between 3G network and 2G network. Inter-RAT handover provides continuous coverage, load sharing, and HCS services, which fully utilizes the existing 2G network resources and thus reduces operator's cost. In this handover, however, GSM and UMTS dual-mode UEs (MSs) are required, and both the GSM MSC and the GSM BSS must be upgraded.
Course Name
N-95
Coverage-based 3G to 2G handover:
The coverage of the 3G network is incontinuous at the initial stage. On the border of the coverage, the poor signal quality of the 3G network triggers the 3G-to-2G measurement. If the signal quality of the 2G network is good enough and all the services of the UE are supported by the 2G network, the coverage-based 3G to 2G handover is triggered. According to the Link Stability Control Algorithm, the RNC needs to trigger the QoS-based 3G to 2G handover to avoid call drops. If the load of the 3G network is heavy and all the RABs of the UE are supported by the 2G network, the load-based 3G to 2G handover is triggered. Based on layered services, the traffic of different classes is handed over to different systems. For example, when an Adaptive Multi Rate (AMR) speech service is requested, this service can be handed over to the 2G network. The principles of the 3G-to-2G handover based on HCS speed estimation are similar to those of inter-frequency handover.
QoS-based 3G to 2G handover:
Load-based 3G to 2G handover:
Service-based 3G to 2G handover:
Speed-based 3G to 2G handover:
Course Name
N-96
2G cell capability: 2G cell capability is configured through the parameter RATCELLTYPE. This parameter indicates whether the cell supports the GSM, GPRS, or EDGE. For more detailed information, please refer to the ADD GSMCELL command. Service capability: The required 2G capability (Req2GCap) specifies the capability of 2G cells required by inter-RAT handover. This indicates whether the service is supported by the GSM, GPRS, or EDGE. For more detailed information, please refer to the ADD TYPRABBASIC command. UE capability: Upon the reception of the UE capability information message, the RNC decides whether to start the inter-RAT measurement. The information indicates whether the UE supports the GSM, GPRS, or EDGE.
Course Name
N-97
The IE service handover indicator indicates the CN policy for the service handover to the 2G network. This IE is indicated in the Radio Access Bearer (RAB) assignment signaling assigned by the CN, or in the following table configured in the RNC by default. The algorithm switch HoSwitch: HO_INTER_RAT_RNC_SERVICE_HO_SWITCH decides whether the service attribute of inter-RAT handover is based on the RNC or the CN.
If the switch is set to on, the service attribute of inter-RAT handover is based on the parameter configured on the RNC side. If the switch is set to off, the service attribute of inter-RAT handover is first based on the CN when the indicator is contained in the RAB assignment signaling assigned by the CN. If the CN does not allocate a service indicator, the service attribute of inter-RAT handover is based on the RNC side.
For more detailed information, please refer to the SET CORRMALGOSWITCH command.
Through the SHIND parameter, the service handover indicators are set as follows:
HO_TO_GSM_SHOULD_BE_PERFORM: means that the handover to the 2G network is performed when 2G signals are available. HO_TO_GSM_SHOULD_NOT_BE_PERFORM: means that the handover to the 2G network is performed when 3G signals are weak but 2G signals are strong. HO_TO_GSM_SHALL_NOT_BE_PERFORM: means that the handover to the 2G network is not performed even when 3G signals are weak but 2G signals are strong.
Indicator Capability For more detailed information, please refer to the ADD TYPRABBASIC command. HO_TO_GSM_SHOULD_ 12.2k 64k 64k 384k 64k 384k >384k NOT_BE_PERFORM HO_TO_GSM_SHALL_N OT_BE_PERFORM HO_TO_GSM_SHOULD_ NOT_BE_PERFORM HO_TO_GSM_SHOULD_ NOT_BE_PERFORM HO_TO_GSM_SHOULD_ NOT_BE_PERFORM HO_TO_GSM_SHOULD_ NOT_BE_PERFORM HO_TO_GSM_SHALL_N OT_BE_PERFORM GSM GSM GPRS EDGE GPRS EDGE EDGE Traffic Class Max Rate Service Handover Required 2G
CN Domain CS CS PS PS PS PS PS
Course Name
N-98
UE Capability
Service Capability (Required by 2G) EDGE GPRS Allowed Allowed Not allowed Not allowed Allowed Allowed Not allowed Not allowed Not allowed Not allowed Not allowed Not allowed GSM Allowed Allowed Allowed Not allowed Allowed Allowed Allowed Not allowed Allowed Allowed Allowed Not allowed
Allowed Allowed Not allowed Not allowed Allowed Allowed Not allowed Not allowed Not allowed Not allowed Not allowed Not allowed
GPRS
GSM
Course Name
N-99
UE Capability
Service Capability (Required by 2G) EDGE GPRS Allowed Allowed Not allowed Not allowed Allowed Allowed Not allowed Not allowed Not allowed Not allowed Not allowed Not allowed GSM Allowed Allowed Allowed Not allowed Allowed Allowed Allowed Not allowed Allowed Allowed Allowed Not allowed
Allowed Not allowed Not allowed Not allowed Not allowed Not allowed Not allowed Not allowed Not allowed Not allowed Not allowed Not allowed
GPRS
GSM
Course Name
N-100
To perform the service-based 3G to 2G handover, the RNC must turn on the related switches for services in the CS and PS domains. When a single CS service is initially set up by the UE, the RNC allows the 3G to 2G service-based handover if CSServiceHOSwitch is set to on. When a single PS service is initially set up by the UE, the RNC allows the service-based 3G-to-2G handover if PSServiceHOSwitch is set to on. For the CS and PS combined services, no service-based handover is triggered. For more detailed information, please refer to the ADD CELLHOCOMM command.
Course Name
N-101
Course Name
N-102
In the triggering phase: The RNC requests the UE to measure through an inter-RAT measurement control message. If the CPICH Ec/No or CPICH RSCP of the current cell is lower than the corresponding threshold, the UE reports event 2D. In the measurement phase: The RNC sends an inter-RAT measurement control message to the UE, requesting the NodeB and UE to start the compressed mode. The RNC also requests the UE to perform the inter-RAT measurement. In this phase, the method of either periodical measurement report or event-triggered measurement report can be used. In the decision phase: After the UE reports event 3A, the RNC performs the handover. Otherwise, the UE periodically generates measurement reports, and the RNC makes a decision after evaluation. In the execution phase: The RNC executes the handover procedure.
Course Name
N-103
When the estimated quality or strength of the currently used frequency is below a certain threshold,2D event will be triggered. Then RNC will initiate the compressed mode to start inter-RAT handover measurement. During compressed mode, if the estimated quality or strength of the currently used frequency is above a certain threshold, 2F event will be triggered. Then RNC will stop the compressed mode.
Course Name
N-104
QUsed is the measurement value of the cell at the currently used frequency. TUsed2d is the absolute quality threshold of the cell at the currently used frequency. Based on the service type and measurement quantity, this threshold can be configured through the following parameters: InterRATCSThd2DEcN0 InterRATR99PsThd2DEcN0 InterRATHThd2DEcN0 InterRATCSThd2DRSCP InterRATR99PsThd2DRSCP InterRATHThd2DRSCP H2d is the event 2D hysteresis value set through the parameter HystFor2D. When the conditions for event 2D are met and maintained in time-to-trigger specified by the parameter TimeToTrig2D, the UE sends the measurement report of event 2D.
Any of the Ec/No and RSCP measurement result can trigger the 2D event.
Course Name
N-105
The parameters for inter-RAT handover 2D are similar with inter-frequency handover. Set above parameters through ADD CELLINTERRATHOCOV/MOD CELLINTERRATHOCOV/SET INTERRATHOCOV.
Course Name
N-106
QUsed is the measurement value of the cell at the currently used frequency. TUsed2f is the absolute quality threshold of the cell at the currently used frequency. Based on the service type and measurement quantity, this threshold can be configured through the following parameters: InterRATCSThd2FEcN0 InterRATR99PsThd2FEcN0 InterRATHThd2FEcN0 InterRATCSThd2FRSCP InterRATR99PsThd2FRSCP InterRATHThd2FRSCP H2f is the event 2F hysteresis value set through the parameter HystFor2F. When the conditions for event 2F are met and maintained in time-to-trigger specified by TrigTime2F, the UE sends the measurement report of event 2F.
Any of Ec/No and RSCP measurement result can trigger the 2F event.
Conditions of event 2F are as follows: TUsed2d - H2d/2 < TUsed2f + H2f/2, for example, (InterRATCSThd2DEcN0HystFor2D/2) < (InterRATCSThd2FEcN0+ HystFor2F/2).
Course Name
N-107
The parameters for inter-RAT handover 2F are similar with inter-frequency handover. Set above parameters through ADD CELLINTERRATHOCOV/MOD CELLINTERRATHOCOV/SET INTERRATHOCOV.
Course Name
N-108
During the coverage-based and QoS-based 3G to 2G handover, the measurements on both inter-frequency and inter-RAT neighboring cells can be made, which enables the cells to provide continuous coverage and high quality. The preconditions for the measurements are as follows: Both inter-frequency and inter-RAT neighboring cells are available. InterFreqRATSwitch is set to SIMINTERFREQRAT. If InterFreqRATSwitch is set to: Inter-frequency measurement (INTERFREQ), the RNC allows the UE to perform only this type of measurement. Inter-RAT measurement (INTERRAT), the RNC allows the UE to perform only this type of measurement. Concurrent inter-frequency and inter-RAT measurement (SIMINTERFREQRAT), the RNC allows the UE to perform both types of measurement at the same time. During the concurrent inter-frequency and inter-RAT measurement, the values of the parameter CoexistMeasThdChoice for event 2D are chosen as follows: When the value COEXIST_MEAS_THD_CHOICE_INTERFREQ is chosen, the inter-frequency measurement threshold for event 2D is used. When the value COEXIST_MEAS_THD_CHOICE_INTERRAT is chosen, the inter-RAT measurement threshold for event 2D is used.
Course Name
N-109
InterFreqRATSwitch
Content: Cell-level switch for inter-frequency and inter-RAT handover. INTERFREQ: only measuring inter-frequency cells and performing interfrequency handover. INTERRAT: only measuring GSM cells and performing inter-RAT handover . SIMINTERFREQRAT: measuring both inter-frequency and inter-RAT cells, performing inter-frequency or inter-RAT handover according to the type of the cell that first meets the handover decision condition. Value range: INTERFREQ, INTERRAT, SIMINTERFREQRAT Physical value range: Inter-frequency handover only, Inter-RAT handover only, Inter-frequency and Inter-RAT handover Content: Type of event 2D/2F measurement thresholds when inter-frequency and inter-RAT measurements coexist. COEXIST_MEAS_THD_CHOICE_INTERFREQ: choosing the inter-frequency oriented parameters as event 2D/2F measurement thresholds for interfrequency measurement. COEXIST_MEAS_THD_CHOICE_INTERRAT: choosing the inter-RAT oriented parameters as event 2D/2F measurement thresholds for inter-RAT measurement. Value range: COEXIST_MEAS_THD_CHOICE_INTERFREQ, COEXIST_MEAS_THD_CHOICE_INTERRAT Physical value range: Choosing the inter-frequency oriented parameters, Choosing the inter-RAT oriented parameters
CoexistMeasThdChoice
Course Name
N-110
When the UE enters the compressed mode, RNC will trigger the inter-RAT handover measurement by one measurement control signaling, so as to request UE test inter-RAT neighbor cell. In this Measurement control message, RNC should inform the UE inter-RAT measurement parameters, including neighbor list and reporting mode as well.
Course Name
N-111
The measurement report mode of inter-RAT handover is configured through the parameter InterRatReportMode. By default, periodically reporting is recommended. Based on the measurement control message received from the RNC, the UE periodically reports the measurement quality of the target cell. Then, based on the measurement report, the RNC makes the handover decision and performs handover. If the reporting mode is periodically reporting: UE only test the Inter-RAT neighbor RSSI only. If the reporting mode is event trigger reporting: UE test the Inter-RAT neighbor RSSI and current cell Ec/No or RSCP: In coverage-based 3G to 2G handover, the event 3A measurement quantity is set through the parameter MeasQuantityOf3A. In QoS-based 3G to 2G handover, the event 3A measurement quantity is set through the parameter UsedFreqMeasQuantityForQos3A.
Course Name
N-112
InterRatReportMode Content: Inter-RAT measurement report mode. When PERIODICAL_REPORTING is selected, you can infer that periodical inter-RAT measurement report is adopted; when EVENT_TRIGGER is selected, you can infer that event-triggered interRAT measurement report is adopted. Value range: PERIODICAL_REPORTING, EVENT_TRIGGER Physical value range: Periodical reporting, Event trigger InterRATPeriodReportInterval Content: Interval that the UE reports inter-RAT measurement results to the RNC. In periodical report mode, the interval between two reports is the configured value. That is, the UE submits reports at intervals of the configured time. Value range: NON_PERIODIC_REPORT, D250, D500, D1000, D2000, D3000, D4000, D6000, D8000, D12000, D16000, D20000, D24000, D28000, D32000, D64000 Physical value range: Non periodical reporting, 250, 500, 1000, 2000, 3000, 4000, 6000, 8000, 12000, 16000, 20000, 24000, 28000, 32000, 64000 Physical unit: ms Set these parameters through ADD CELLINTERRATHOCOV/MOD CELLINTERRATHOCOV/SET INTERRATHOCOV.
Course Name
N-113
InterRATMeasTime
Content: Timer length for inter-RAT measurement. After inter-RAT measurement starts, if no inter-RAT handover is performed when this timer times out, the inter-RAT measurement is stopped. In addition, the compressed mode is deactivated, if any; If the value is 0, you can infer that the inter-RAT measurement timer is not started. Value range: 0~512 Physical value range: 0~512; step: 1 Physical unit: s Content: Measurement quantity used in coverage-based inter-RAT measurement in event 3A-triggered reporting mode. CPICH_Ec/No indicates that the Ec/No measurement quantity is used for event 3A measurement. The physical unit is dB. CPICH_RSCP indicates that the RSCP measurement quantity is used for event 3A measurement. The physical unit is dBm. AUTO indicates that the Ec/N0 measurement quantity is used for event 3A measurement if RNC receives the Ec/No 2D firstly; the RSCP measurement quantity is used for event 3A measurement if RNC receives the RSCP 2D firstly.
MeasQuantityOf3A
This parameter can be configured only when InterRatReportMode is set to EVENT_TRIGGER. Value range: CPICH_EC/NO, CPICH_RSCP, AUTO Physical value range: CPICH_EC/NO, CPICH_RSCP, AUTO
Course Name
N-114
Course Name
N-115
Mother_RAT is the measurement result of inter-RAT handover (RSSI) received by the RNC. CIOother_RAT is the cell individual offset value of the target cell. It is equal to the sum of CIO and CIOOffset. Tother_RAT is the decision threshold of inter-RAT hard handover.Based on the service type and measurement quantity, this threshold can be configured through the following parameters: TargetRatCsThd TargetRatR99PsThd TargetRatHThd These thresholds are the same as the quality threshold of event 3A. H is the inter-RAT handover hysteresis value set through HystforInterRAT. The length of the time-to-trigger timer is configured through the parameter TimeToTrigForVerify (with BSIC acknowledged, and it is the default setting) or the parameter TimeToTrigForNonVerify (with BSIC unacknowledged).
Course Name
N-116
CIO
Content: This parameter is used for the inter-RAT handover decision in combination with the neighboring cell oriented CIO. The larger the sum, the higher the handover priority of the GSM cell. The smaller the sum, the lower the handover priority of the GSM cell. The parameter is generally set to 0. Value range: -50~50 Physical value range: -50~50; step: 1 Physical unit: dB
Set this parameter through ADD GSMCELL/MOD GSMCELL. CIOOffset Content: This parameter is used for decision making for the inter-RAT handover. The larger the value of the parameter, the higher the handover priority of the GSM cell. The smaller the value of the parameter, the lower the handover priority of the GSM cell. Value range: -50~50
Physical value range: -50~50; step: 1 Physical unit: dB Set this parameter through ADD GSMNCELL/MOD GSMNCELL.
Course Name
N-117
HystforInterRAT
Content: Hysteresis value for inter-RAT measurement periodical reports. This parameter aims to prevent the mis-decision caused by unexpected jitters of signals during interRAT handover decisions. The HystforInterRAT and the inter-RAT handover decision threshold determine whether to trigger inter-RAT handovers. Value range: 0~15 Physical value range: 0~15; step: 0.5 Physical unit: dB Content: Time delay for triggering handovers to GSM cells with verified BSIC. During the period of time specified by this parameter, if the signal quality in a neighboring GSM cell satisfies inter-RAT handover conditions and the neighboring GSM cell is verified, an inter-RAT handover is triggered. Value range: 0~64000 Physical value range: 0~64000; step: 1 Physical unit: ms Content: Time delay for triggering handovers to GSM cells with non-verified BSIC. During the period of time specified by this parameter, if the signal quality in a neighboring GSM cell satisfies inter-RAT handover conditions and the neighboring GSM cell is not verified, an inter-RAT handover is triggered. When the value of this parameter is 65535, the RNC does not perform inter-RAT handovers to non-verified GSM cells. Value range: 0~64000, 65535 Physical value range: 0~64000, 65535; step: 1 Physical unit: ms
TimeToTrigForVerify
TimeToTrigForNonVerify
Course Name
N-118
Course Name
N-119
QUsed is the measurement value of the cell at the currently used frequency. TUsed is the absolute quality threshold of the cell that uses the current frequency. MOtherRAT is the measurement value of the cell (in another RAT) in the reporting range. CIOOtherRAT is the cell individual offset value of the cell (in another RAT) in the reporting range which is equal to the sum of CIO and CIOOffset. TOtherRAT is the absolute inter-RAT handover threshold. Based on different service types (CS , PS domain R99 service, or PS domain HSPA service), this threshold can be configured through the following parameters: TargetRatCsThd TargetRatR99PsThd TargetRatHThd H3a is 3A hysteresis, the hysteresis value of event 3A. When the conditions for event 3A are met and maintained in time-to-trigger specified by TrigTime3A the UE sends the measurement report of event 3A.
Course Name
N-120
UsedFreqCSThdEcN0 Content: Threshold of used frequency quality for triggering inter-RAT measurement with measurement quantity of Ec/No for CS domain services. For CS domain services, when Ec/No is used as the measurement quantity for inter-RAT measurement, this parameter is used to set measurement control on the event 3A. The event 3A is triggered, when the quality of the currently used UTRAN frequency is below this threshold and the TargetRatCsThd is reached. Value range: -24~0 Physical value range: -24~0; step: 1 Physical unit: dB TargetRatCsThd Content: Quality requirement for the inter-RAT cell during an inter-RAT handover with CS domain services. For CS domain services, if the value of InterRatReportMode is set to EVENT_TRIGGER, this parameter is used to set the measurement control of event 3A. One of the necessary conditions for triggering event 3A can be met only when the quality of the target frequency is higher than this threshold; if the value of InterRatReportMode is set to PERIODICAL_REPORTING, this parameter is used to evaluate inter-RAT coverage handovers at the RNC. Note that the value 0 means the physical value is smaller than 110 dBm. Value range: 0~63 Physical value range: Lower than -110, -110~-48 (1: -110; 2: -109; ...; 63: -48 ) Physical unit: dBm Set these parameters through ADD CELLINTERRATHOCOV/MOD CELLINTERRATHOCOV/SET Confidential Information of INTERRATHOCOV. Huawei. No Spreading Without Permission
Course Name
N-121
Course Name
N-122
Hystfor3A
Content: Hysteresis value for the event 3A. The value of this parameter correlates with slow fading. The larger the value of this parameter, the stronger the capability of resisting signal fluctuation. Thus, the ping-pong effect can be avoided, but the speed of the handover algorithm to respond to signal change becomes lower. If the inter-RAT handover hysteresis is set to an excessively high value, the GSM cell to which the UE is handed over must be of good quality. Therefore, the conditions for triggering the inter-RAT handover decision are hard to be satisfied, and the call drop rate increases. Value range: 0~15 Physical value range: 0~7.5; step: 0.5 Physical unit: dB
TrigTime3A
Content: Time delay to trigger the event 3A. The value of this parameter correlates with slow fading. The larger the value of this parameter, the lower the incorrect decision probability, but the slower the response of the event 3A to measurement signal change.
Value range: D0, D10, D20, D40, D60, D80, D100, D120, D160, D200, D240, D320, D640, D1280, D2560, D5000 Physical value range: 0, 10, 20, 40, 60, 80, 100, 120, 160, 200, 240, 320, 640, 1280, 2560, 5000 Physical unit: s
Course Name
N-123
PeriodFor3A Content: Retry period for the event 3A. This parameter defines the length of the event 3A retry period. The smaller the value of this parameter, the more frequent the handover retry due to inter-RAT handover failure, and the faster the UE to be successfully handed over to the target cell whose load is restored, thus lowering the probability of call drops. In this case, however, frequent handover retry brings more load to the RNC system. Value range: 1~64 Physical value range: 500~32000; step: 500 Physical unit: ms AmntOfRpt3A Content: Maximum retry times of the event 3A. This parameter defines the number of times for event 3A retry when the measurement control is valid. The larger the value of this parameter, the larger the number of times for inter-RAT handover retry, and the higher probability the UE is successfully handed over to the target cell whose load is restored. When the retry times reaches the maximum value, the RNC stops the retry process. Or if the measurement control message is released, the retry will be immediately stopped. Value range: 0~63 Physical value range: 0~62, 63: Infinity; step: 1 Set these parameters through ADD CELLINTERRATHOCOV / MOD CELLINTERRATHOCOV / SET INTERRATHOCOV.
Course Name
N-124
PeriodFor3C Content: Retry period for the event 3C. This parameter defines the length of the event 3C retry period. The smaller the value of this parameter, the more frequent the handover retry due to inter-RAT handover failure, and the faster the UE to be successfully handed over to the target cell whose load is restored, thus lowering the probability of call drops. In this case, however, frequent handover retry brings more load to the RNC system. Value range: 1~64 Physical value range: 500~32000; step: 500 Physical unit: ms AmntOfRpt3C Content: Maximum retry times of the event 3C. This parameter defines the number of times for event 3C retry when the measurement control is valid. The larger the value of this parameter, the larger the number of times for inter-RAT handover retry, and the higher probability the UE is successfully handed over to the target cell whose load is restored. When the retry times reaches the maximum value, the RNC stops the retry process. Or if the measurement control message is released, the retry will be immediately stopped. Value range: 0~63 Physical value range: 0~62, 63: Infinity; step: 1 Set these parameters through ADD CELLINTERRATHOCOV / MOD CELLINTERRATHOCOV / SET INTERRATHOCOV.
Confidential Information of Huawei. No Spreading Without Permission
Course Name
N-125
Course Name
N-126
The above figure shows the signaling procedures for the 3G-to-2G handover in the CS domain. The 2G messages shown in the figure are for your reference only.
Course Name
N-127
Signaling procedures for CS inter-RAT handover: 1. The SRNC sends the 3G MSC a RANAP message RELOCATION REQUIRED if the condition of Inter-RAT outgoing handover is met. 2. As indicated in the received message, the 3G MSC forwards this request to the 2G MSC on the MAP/E interface through a MAP message PREPARE HANDOVER. 3. The 2G MSC forwards the request to the BSC. The message shown in the figure is for reference only and is subject to the actual condition of the GSM. 4. The BSC responds to this request. The message shown in the figure is for reference only and is subject to the actual condition of the GSM. 5. Once the initial procedures are completed in the 2G MSC/BSS, the 2G MSC returns a MAP/E message PREPARE HANDOVER RESPONSE. 6. The 3G MSC sends the SRNC a RANAP message RELOCATION COMMAND. 7. The SRNC sends the UE an RRC message HANDOVER FROM UTRAN through the existing RRC connection. This message may include information from one or several other systems. 8. The BSC performs handover detection. The figure does not show such procedures as GSM BSS synchronization. The message shown in the figure is for reference only and is subject to the actual condition of the GSM. 9. The UE sends the BSC a HANDOVER COMPLETE message. 10. The BSC sends the MSC a HANDOVER COMPLETE message. The message shown in the figure is for reference only and is subject to the actual condition of the GSM. 11. After detecting the UE in the coverage area of the GSM, the MSC sends the CN a MAP/E message SEND END SIGNAL REQUEST. 12. The CN sends the former SRNC an IU RELEASE COMMAND message, requesting the former SRNC to release the allocated resource. 13. After the bearer resource is released in the UMTS, the former SRNC sends the CN an IU RELEASE COMPLETE message. 14. After the call ends, the CN sends the MSC a MAP/E message SEND END SIGNAL RESPONSE.
Course Name
N-128
For a UE in idle mode or connected mode, if the SGSN changes with the shift of the system that the UE accesses from 3G network to 2G network, the interSGSN handover will be performed. The handover procedures are different in the following two cases: When the UE is in CELL_DCH state: The 3G to 2G handover in the PS domain is triggered after the UTRAN sends a CELL CHANGE ORDER FROM UTRAN message. When the UE is in CELL_FACH, CELL_PCH, or URA_PCH state: The 3G to 2G handover in the PS domain is triggered through the cell reselection. The above figure shows an example of handover for the UE in CELL_FACH, CELL_PCH, or URA_PCH state. When the UE is in idle mode, the cell reselection procedure does not include the elementary procedures marked "UE CONNECTED" in figure.
Course Name
N-129
Signaling procedures for PS inter-RAT handover: 1. The UE in CELL_DCH state or the UTRAN (when the UE is in CELL_FACH state) decides to initiate an Inter-RAT handover in the PS domain to hand over the UE to a new GSM cell and stop the data transmission between the UE and the network. 2. The UE sends a ROUTING AREA UPDATE REQUEST message to the 2G SGSN. The Update Type in the message indicates RA update, combined RA/LA update, or combined RA/LA update with IMSI attach. The BSS adds the CGI including the RAC and LAC of the cell to the received message before forwarding the message to a new 2G SGSN. 3. The new 2G SGSN sends an SGSN CONTEXT REQUEST message to the old 3G SGSN to obtain the MM and PDP contexts. The old 3G SGSN validates the old P-TMSI Signature. If the old P-TMSI Signature is valid, the old 3G SGSN starts a timer. Otherwise, the old 3G SGSN responds with an error cause. 4. If the UE stays in connected mode before handover, the old 3G SGSN sends an SRNS CONTEXT REQUEST message. After receiving this message, the SRNS buffers the DPUs, stops sending the PDUs to the UE, and sends an SRNS CONTEXT RESPONSE message to the old 3G SGSN. 5. The old 3G SGSN sends an SGSN CONTEXT RESPONSE message to the 2G SGSN, including the MM and PDP contexts. 6. The security functions can be executed. 7. The new 2G SGSN sends an SGSN CONTEXT ACKNOWLEDGE message to the old 3G SGSN. This informs the old 3G SGSN that the new 2G SGSN is ready to receive the PDUs belonging to the activated PDP contexts. 8. The old 3G SGSN sends a DATA FORWARD COMMAND message to the SRNS. The SRNS starts a data-forwarding timer and sends the buffered PDUs to the old 3G SGSN. 9. The old 3G SGSN tunnels the GTP PDUs to the new 2G SGSN. In the PDUs, the sequence numbers in the GTP header remain unchanged. 10. The new 2G SGSN sends an UPDATE PDP CONTEXT REQUEST message to each related GGSN. Each GGSN sends an UPDATE PDP CONTEXT RESPONSE message after updating its PDP context fields. 11. The new 2G SGSN sends an UPDATE GPRS LOCATION message, requesting the HLR to modify the SGSN number. 12. The HLR sends a CANCEL LOCATION message to the old 3G SGSN. The old 3G SGSN responds with a CANCEL LOCATION ACK message. After the timer expires, the old 3G SGSN removes the MM and PDP contexts. 13. The old 3G SGSN sends an IU RELEASE COMMAND message to the SRNS. After the data-forwarding timer expires, the SRNS responds with an IU RELEASE COMPLETE message. 14. The HLR sends an INSERT SUBSCRIBER DATA message to the new 2G SGSN. The 2G SGSN constructs an MM context and PDP contexts for the UE and returns an INSERT SUBSCRIBER DATA ACK message to the HLR. 15. The HLR sends an UPDATE GPRS LOCATION ACK message to the new 2G SGSN.
Confidential Information of Huawei. No Spreading Without Permission
Course Name
N-130
16. If the association has to be established, the new 2G SGSN sends a LOCATION UPDATE REQUEST message to the VLR. The VLR stores the SGSN number for creating or updating the association. 17. If the subscriber data in the VLR is marked as not confirmed by the HLR, the new VLR informs the HLR. The HLR cancels the old VLR and inserts subscriber data in the new VLR. 1. The new VLR sends an UPDATE LOCATION message to the HLR. 2. The HLR cancels the data in the old VLR by sending a CANCEL LOCATION message to the old VLR. 3. The old VLR acknowledges the message by responding with a CANCEL LOCATION ACK message. 4. The HLR sends an INSERT SUBSCRIBER DATA message to the new VLR. 5. The new VLR acknowledges the message by responding with an INSERT SUBSCRIBER DATA ACK message. 6. The HLR responds with a UPDATE LOCATION ACK message to the new VLR. 17. The new VLR allocates a new TMSI and responds with a LOCATION UPDATE ACCEPT message to the 2G SGSN. 18. The new 2G SGSN checks the presence of the MS in the new RA. If all checks are successful, the new 2G SGSN constructs the MM and PDP contexts for the MS. A logical link is established between the new 2G SGSN and the UE. The 2G SGSN responds to the UE with a ROUTING AREA UPDATE ACCEPT message. 19. The UE acknowledges the new P-TMSI by returning a ROUTING AREA UPDATE COMPLETE message, including all PDUs successfully sent to the UE before the routing area update procedure. 20. The new 2G SGSN sends a TMSI REALLOCATION COMPLETE message to the new VLR if the UE confirms the VLR TMSI. 21. The 2G SGSN and the BSS perform the BSS PACKET FLOW CONTEXT procedure.