Está en la página 1de 18

Build Quality with Engineering Ethics

Study Integration Ericsson RBS6601 -3G Dtac Project

GSM RAN
Core Network
Radio Access Network
External Management System Mun A-ter BSC TRC/BSC Abis Um RBS RBS RBS
Mobile Station

OSS-RC Mun TEMS

Network Management Environment

Mobile Station

WCDMA RaN

LTE RAN
Core Network
External Management System Mun OSS-RC Mun Mul X2 Uu RBS RBS RBS
User Equipment

Radio Access Network

S1

TEMS

Network Management Environment

User Equipment

RBS 6601 main remote Solution

Main unit - duw


IP Transmission
TNB: Optical, TNA: Electrical

SCU-External Alarm

6xSFP module RRU connection

4xE1

Local O&M via serial


Local O&M via Ethernet LAN

Tools list
As attached file

Thin client with


Windows (2000, XP or Vista) Java Runtime Environment - JRE 1.5 Hyper Terminal or similar function for serial connection Element Manager (EMAS) Software

DTAC

3 G RAN Process
( 1 /4 )

Site integration process


D T A CN S P- N S C

NB Update in NSN 2 G Network

check the existing alarm NSN before integration

D T A C/ F O E NG

Approve by ENG ?

ENG Submit NB info to NSP - NSC

FO inform SOC -FE

E c t- D T

E C T- I N T

Detailed RND and ATND completed

Data Transcript (DT ) Production Data trascripts

Submit to DT ECT -INT and DTAC - ENG for approval

Submit DT to ECT INT (RNC )

E c t- i n t ( R N C)

check the existing alarm E /// before integration

Load Data Scripts in RNC

NSN
Site Acceptance completed Inform FO b efore performing Activity

A S P- I N t ( N O DE B )

Start

NSN or E /// Network

E ///
Inform ECT - INT

Record the external alarm

D U r a ti o n

DTAC 3G RAN Pr o c es s Sit e in t eg r a t io n pr o c es s (2/4 )


Ec t -in t (RNC) DTAC- TRS DTAC-FO
Activate cells acknowledgem ent

Confirm TRS commissioning cmpleted

Trouble Shooting (Max 2 HRS)

TRS Working?

Inform ASPINT to cancel the integration activities

Y
NB Update In E/// 2G & 3G Network at OSS Perform Activate Cells & Test from RNC

ASP-INt (NODE B)

Inform DTACTRS for TRS issues

Inform PM for integration cancellation

Trouble Shooting (Max 2 Hrs)

N
Power On E/// RBS and Verify Voltage Load Data Scripts into Node B TRS Test is Working Properly?

N Y
Check and Clear Critical Hardware Alarms

Connect TRS to E/// RBS

Internal Alarm Passed?

Inform E/// RNC and FO To Activate Cells

DUr a t io n

DTAC 3G RAN Pr o c es s Sit e in t eg r a t io n pr o c es s (3/4 )


DTAC NSPNSC DTAC-FO

Check alarm status

ECT-INT (RNC)

Trouble Shooting

Update OSS

Perform Test Call (Support)

ASP-INt (NODE B)

N
Record FingerPrint & Emergency Licence Keys Site integration completed Check alarm status with FO Before leaving site Inform ECTINT to lock sectors

Perform Test Calls

Test Calls Pass?

External alarm test (3G)

Fin g er pr in t v a l id o n l y 30 days

d u r a t io n

10

DTAC 3G RAN Pr o c es s Sit e in t eg r a t io n pr o c es s (4 /4 )


DTAC-FO ECT-INT (RNC) DTAC NSPNSC

Perform lock sectors

Generate Full Licence Key For Node B From FingerPrint

Load Node B Full Licence Key In OSS

End

ASP-INt (NODE B)

Site cleaning

Inform FO Before Leaving Site

d u r a t io n

11

Dtac integration workflow


1. Inform SOC-FE before doing activity 2. Completion the Installation 3. Add Module for Rectifier 3.1 Plug in additional Module 3.2 Commissioning 4. Verify voltage & Power on Ericsson RBS 4. Load Data Scripts into Node B - LEOBARD 5. Load Data Scripts in RNC -ERICSSON 6. Check and clear critical hardware alarms 7. Internal alarm pass? 7.1 Pass ( go to step 8) 7.2 Not Pass : 7.2.1 Check and clear critical hardware alarms ( go to step 7) 8. Inform E/// BSC and FO to activate Cells 9. Activate Cells (Site Integrated) 10. Test calls 11. Test call OK (go to step 11) 16.2 Test call Not OK 16.2.1 Trouble shooting ( go to step 10) 11. Site integration completed& then Lock the site 12. inform ECT INT 21. Inform SOC-FE before leaving site 22. upload test result to SH & submit to FO and ENG.

12

Configuration data
IP and router configuration Design documents prepare by design team (RND & ATND) Scripts for on-site loading include:
OAM Access Configuration Site Equipment Configuration IUB script

13

OAM Access file

script AYA0123U08_NIKOM_SAHARATANA_OAM_01.xml xml (eXtensible Markup Language) xml http://notepad-plusplus.org/ oam 1.IP address MU (NodeB or RBS station) =169.254.1.1 subnet Mark=255.255.0.0 255.255.0.0 2. NodeB (OIL) TNB Ip=10.232.27.145 OAM (IP=10.232.27.151) NTPserver (IP=10.233.0.105 10.233.0.105) 255.255.255.240 IP address IP ntp network time protocol intranet gigabit ethernet , gigabitethernet http://guru.google.co.th/guru/thread?tid=68e9a256635 f4617&pli=1 3. localtimezone=VST vst Vietnam Standard Time time zone http://publib.boulder.ibm.com/tividd/td/TWS/SC321274-02/en_US/HTML/SRF_mst273.htm MU NodeB intranet optic 14

SE file

script AYA0123U08_NIKOM_SAHARATANA_SE_02.xml xml (eXtensible Markup Language) xml http://notepad-plus-plus.org/ SE (Site Equipment Configuration) 1. (Site Location Configuration) 1.1 (AYA0123-U08) (Nikom_Saharatana) 1.2 Antenna 2. Sector Capability <SectorCapability sectorNumber="1" radioBuildingBlock="RBB12_1A" cpriLineRate="Ox4" primaryPortId="BU1_A"/> 3.Sector Equipment Configuration 3.1 TMA config (TMA=Tower Mounted Amplifier) 3.2 Antenna config , Tilt, 3.3 Ret config (RET=Remote Electrical Tilt ) Tilt 0120 Alarm SAU 12 type PortID: 1. TMB/TMA Relay Alarm 2. Fan Ventilation system Fail/Ventilation Control Fail 3. Solar Cell Inverter alarm/UPS 4. OB Light Alarm 5. Main AC 6. Charger 1800 48 Volt 7. Charger High Temperature/ Room High temperature 8. Surge Protection 9. Door Alarm / Fire Alarm 10. Battery Backup Failed/Solar Cell Batt Low-Volt 11. Generator Start 12. Generator Low Fuel/Gen not start

15

MO (Managed Object) file

//================================================================// // Project : DTAC_3G_Phase7 // // Created By : Somchai Fakchuen // // Date/Time Created : 7/20/2012 4:16:14 PM // // Site : AYA0123-U08 // // RBS Id : 0196 // // Number of Sector : 3 Sector // //================================================================// // Running at Node : RBS // //================================================================// CREATE ( parent "ManagedElement=1,IpSystem=1" identity "1" moType IpAccessSctp exception none nrOfAttributes 2 userLabel String "IpAccessSctp_1" ipAccessHostEtRef1 Ref "ManagedElement=1,IpSystem=1,IpAccessHostEt=1" ) CREATE ( parent "ManagedElement=1,TransportNetwork=1" identity "1" moType Sctp exception none nrOfAttributes 13 userLabel String "Sctp_1" numberOfAssociations Integer 2 minimumRto Integer 10 maximumRto Integer 40 initialRto Integer 20 associationMaxRtx Integer 12 pathMaxRtx Integer 6 maxUserDataSize Integer 556 mBuffer Integer 16 nThreshold Integer 12 initialAdRecWin Integer 16384 rpuId Ref "ManagedElement=1,SwManagement=1,ReliableProgramUniter=sctp_host" ipAccessSctpRef Ref "ManagedElement=1,IpSystem=1,IpAccessSctp=1" )

script AYA0123U08_NIKOM_SAHARATANA_Iub_03 lub lub RBS RNC

http://www.scribd.com/doc/56158784/MOshellUserGuide

16

MO (Managed Object) file

//================================================================// // Project : DTAC_3G_Phase7 // // Created By : Somchai Fakchuen // // Date/Time Created : 7/20/2012 4:16:14 PM // // Site : AYA0123-U08 // // RBS Id : 0196 // // Number of Sector : 3 Sector // //================================================================// // Running at Node : RBS // //================================================================// CREATE ( parent "ManagedElement=1,IpSystem=1" identity "1" moType IpAccessSctp exception none nrOfAttributes 2 userLabel String "IpAccessSctp_1" ipAccessHostEtRef1 Ref "ManagedElement=1,IpSystem=1,IpAccessHostEt=1" ) CREATE ( parent "ManagedElement=1,TransportNetwork=1" identity "1" moType Sctp exception none nrOfAttributes 13 userLabel String "Sctp_1" numberOfAssociations Integer 2 minimumRto Integer 10 maximumRto Integer 40 initialRto Integer 20 associationMaxRtx Integer 12 pathMaxRtx Integer 6 maxUserDataSize Integer 556 mBuffer Integer 16 nThreshold Integer 12 initialAdRecWin Integer 16384 rpuId Ref "ManagedElement=1,SwManagement=1,ReliableProgramUniter=sctp_host" ipAccessSctpRef Ref "ManagedElement=1,IpSystem=1,IpAccessSctp=1" )

script AYA0123U08_NIKOM_SAHARATANA_Iub_03 lub lub RBS RNC

http://www.scribd.com/doc/56158784/MOshellUserGuide MO= Managed Object

17

MO (Managed Object) file

Hyperterminal OSE shell (COLI) serial port (RS232) Filezilla Total commander ( ftp file transfer protocol) EMAs ( element manager) File Zilla server ( file zilla) Server moshell () NodeB http://storify.com/kenglife/o-and-m-storify

18

También podría gustarte