FUSES

HHM

HIGH VOLTAGE FUSES


MOTOR CIRCUIT PROTECTION DIN AND BRITISH STANDARD

SIBA Motor Rated Fuses are available in


- German DIN Standard and
- British Standard Design
The large variety in body sizes / mounting
style / Voltage and Amp rating allow great
flexibility for the designer of switchboard
panels.
Standards:
- Dimensions:
- Electrical:

DIN 43625 and


BS 2692
IEC 60644
IEC 60470
IEC 60282-1

Class:

Back up

Voltage Ratings: AC 3.6 - 7.2 kV


Current Ratings: 50 - 315 A

Features / Benefits
 Protection of Motor circuits according IEC 60644
 High resistance against cyclic and peak current loads / avoiding ageing because of high
motor start up currents

 Low power losses / minimising temperature increase in narrow contactor enclosures


 Low minimum interrupting currents for operation of overcurrents in the range 3 - 3.5 x rated
current

 Availability of SIBA-Temperature limiters for switchgear protection against excessive


temperature rise

 Type tested according IEC 60470 in cooperation with the major European Panel builders
 Available in DIN 43625 and BS 2692 dimensions

HHM 3

HHM

FUSES

HIGH VOLTAGE FUSES


MOTOR CIRCUIT PROTECTION DIN AND BS STANDARD

Selection
Guide
Size

Rated Voltage
AC
kV

Class

Part No.

Selector
Guide
Page

Techn.
Data
Page

TA2
TA4
E= 292 mm
E= 292 mm
E= 292 mm
E= 442 mm
E= 442 mm
E= 442 mm

3.6
7.2
3.6
3.6
3.6
7.2
7.2
7.2

Back up
Back up
Back up
Back up
Back up
Back up
Back up
Back up

30 269 56
30 271 56
30 201 53
30 202 53
30 200 54
30 108 53
30 109 53
30 110 54

HHM
HHM
HHM
HHM
HHM
HHM
HHM
HHM

HHM
HHM
HHM
HHM
HHM
HHM
HHM
HHM

HHM 4

5
6
7
7
7
7
7
7

8
8
9
9
9
9
9
9

HHM

FUSES

HIGH VOLTAGE FUSES


MOTOR CIRCUIT PROTECTION BRITISH STANDARD

Size
TA 2

Rated voltage
AC 3.6 kV

Rated
current
A

Part No.

50
63
80
100
125
160
200
224
250
315

30 269 56
30 269 56
30 269 56
30 269 56
30 269 56
30 269 56
30 269 56
30 269 56
30 269 56
30 269 56

Standard
BS 2692-1 IEC 60282-1 IEC 60644
Breaking
current
kA

Weight

50
50
50
50
50
50
50
50
50
50

3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9

Pack

(kg/1)

1
1
1
1
1
1
1
1
1
1

A
B
C1
C2
D
E
F
H
I
J
L
N
O

10.00 (254 mm)


2.56 (65 mm)
1.50 (38 mm)
1.26 (32 mm)
2.99 (76 mm)
12.00 (305 mm)
0.12 (3 mm)
3.11 (79 mm)
0.91 (23 mm)
0.43 (11 mm)
13.39 (337 mm)
0.51 (13 mm)
0.39 (10 mm)

HHM 5

HHM

FUSES

HIGH VOLTAGE FUSES


MOTOR CIRCUIT PROTECTION BRITISH STANDARD

Size
TA 4

A
B
C1
C2
D
E
F
H
I
J
L
N
O

Rated voltage
AC 7.2 kV

Rated
current
A

Part No.

50
63
80
100
125
160
200
224
250
315

30 271 56
30 271 56
30 271 56
30 271 56
30 271 56
30 271 56
30 271 56
30 271 56
30 271 56
30 271 56

15.87 (403 mm)


2.56 (65 mm)
1.50 (38 mm)
1.26 (32 mm)
3.00 (76 mm)
17.87 (454 mm)
0.12 (3 mm)
3.10 (79 mm)
0.90 (23 mm)
0.43 (11 mm)
19.13 (486 mm)
0.50 (13 mm)
0.40 (10 mm)

HHM 6

Standard
BS 2692-1 IEC 60282-1 IEC 60644
Breaking
current
kA

Weight

50
50
50
50
50
50
50
50
50
50

4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2

Pack

(kg/1)

1
1
1
1
1
1
1
1
1
1

HHM

FUSES

HIGH VOLTAGE FUSES


MOTOR CIRCUIT PROTECTION BRITISH STANDARD

DIN Size
E= 292 mm

Rated voltage
AC 3.6 kV

Rated
current
A

Part No.

50
63
80
100
125
160
200
224
250
315

30 201 53
30 201 53
30 201 53
30 201 53
30 202 53
30 202 53
30 200 54
30 200 54
30 200 54
30 200 54

DIN Size
E= 442 mm

Standard
IEC 60282-1 IEC 60644

D= Diameter
inch
mm
2.07
2.07
2.07
2.07
2.64
2.64
3.35
3.35
3.35
3.35

53
53
53
53
67
67
85
85
85
85

Breaking
current
kA

Weight

50
50
50
50
50
50
50
50
50
50

1.6
1.6
1.6
1.6
2.0
2.0
3.8
3.8
3.8
3.8

Rated voltage
AC 7.2 kV

Rated
current
A

Part No.

50
63
80
100
125
160
200
224
250
315

30 108 53
30 108 53
30 108 53
30 108 53
30 109 53
30 109 53
30 110 54
30 110 54
30 110 54
30 110 54

1
1
1
1
1
1
1
1
1
1

Standard
IEC 60282-1 IEC 60644

D= Diameter
inch
mm
2.07
2.07
2.07
2.07
2.64
2.64
3.35
3.35
3.35
3.35

Pack

(kg/1)

53
53
53
53
67
67
85
85
85
85

Breaking
current
kA

Weight

50
50
50
50
50
50
50
50
50
50

2.2
2.2
2.2
2.2
2.9
2.9
5.4
5.4
5.4
5.4

Pack

(kg/1)

1
1
1
1
1
1
1
1
1
1

A
F
O
N

1.77
1.30
0.40
1.38

(45 mm)
(33 mm)
(10 mm)
(306 mm)

HHM 7

HHM
Size
TA 2
Rated
current
A
50
63
80
100
125
160
200
224
250
315

Rated voltage
AC 3.6 kV
Part No.

30 269 56
30 269 56
30 269 56
30 269 56
30 269 56
30 269 56
30 269 56
30 269 56
30 269 56
30 269 56

Size
TA 4
Rated
current
A
50
63
80
100
125
160
200
224
250
315

Electrical Characteristics

FUSES

Breaking
current
kA

Pre-arcing
I2t-value
A2s

Total
I2t-value
A2s

Power
loss
W

50
50
50
50
50
50
50
50
50
50

2,400
3,800
6,100
13,000
23,000
65,000
119,000
139,000
290,000
545,000

9,600
14,800
22,800
48,000
83,000
220,000
382,000
423,000
826,000
1,450,000

23
31
36
39
44
46
54
57
61
70

Rated voltage
AC 7.2 kV
Part No.

30 271 56
30 271 56
30 271 56
30 271 56
30 271 56
30 271 56
30 271 56
30 271 56
30 271 56
30 271 56

Class
Back up

Class
Back up

Breaking
current
kA

Pre-arcing
I2t-value
A2s

Total
I2t-value
A2s

Power
loss
W

50
50
50
50
50
50
50
50
50
50

2,400
3,800
6,100
13,000
23,000
65,000
119,000
139,000
290,000
545,000

10,500
16,500
25,500
54,000
92,500
247,000
428,000
475,000
928,000
1,610,000

34
47
56
60
68
71
83
88
92
107

TIME CURRENT CHARACTERISTICS AND CUT OFF CURRENT DIAGRAM


PLEASE REFER TO PAGES HHM 10 AND HHM 11
HHM 8

Electrical Characteristics

DIN Size
E= 292 mm
Rated
current
A
50
63
80
100
125
160
200
224
250
315

Part No.

30 201 53
30 201 53
30 201 53
30 201 53
30 202 53
30 202 53
30 200 54
30 200 54
30 200 54
30 200 54

DIN Size
E= 442 mm
Rated
current
A
50
63
80
100
125
160
200
225
250
315

Part No.

30 108 53
30 108 53
30 108 53
30 108 53
30 109 53
30 109 53
30 110 54
30 110 54
30 110 54
30 110 54

Rated voltage
AC 3.6 kV

FUSES

Class
Back up

Breaking
current
kA

Pre-arcing
I2t-value
A2s

Total
I2t-value
A2s

Power
loss
W

50
50
50
50
50
50
50
50
50
50

2,400
3,800
6,100
13,000
23,000
65,000
119,000
139,000
290,000
545,000

9,050
14,000
21,500
46,500
79,500
215,000
370,000
415,000
810,000
1,380,000

27
38
44
47
51
53
58
61
64
75

Rated voltage
AC 7.2 kV

HHM

Class
Back up

Breaking
current
kA

Pre-arcing
I2t-value
A2s

Total
I2t-value
A2s

Power
loss
W

50
50
50
50
50
50
50
50
50
50

2,400
3,800
6,100
13,000
23,000
65,000
119,000
139,000
290,000
545,000

10,050
15,600
24,400
52,000
89,500
239,500
419,000
465,000
909,000
1,577,000

39
55
66
71
73
76
88
94
98
115

TIME CURRENT CHARACTERISTICS AND CUT OFF CURRENT DIAGRAM


PLEASE REFER TO PAGES HHM 10 AND HHM 11
HHM 9

HHM

Electrical Characteristics

FUSES

Time Current Characteristics

Virtual Pre-arcing Time

t(s)

RMS Prospective Current

HHM 10

I(A)

Electrical Characteristics

FUSES

HHM

Cut Off Current Diagram

Cut-off Current Peak

Ic
(kA)

Prospective Short Circuit Current

I(kA)

HHM 11

HHM

Electrical Characteristics

FUSES

Recommendation

Motor Circuit Application

6 sec

Fuse link rated current

Motor starts / h

Motor starting current (A)

Fuse selection for motors with a run up time not exceeding 6 seconds;
e.g. Pump motors.
Two immediate successive starts are admissible.

HHM 12

Electrical Characteristics

Recommendation

FUSES

Motor Circuit Application

HHM
15 sec

Fuse link rated current

Motor starts / h

Motor starting current (A)

Fuse selection for motors with a run up time not exceeding 15 seconds;
e.g. Fan motors.
Two immediate successive starts are admissible.

HHM 13

HHM

Electrical Characteristics

FUSES

Recommendation

Motor Circuit Application

30 sec

Fuse link rated current

Motor starts / h

Motor starting current (A)

Fuse selection for motors with a run up time not exceeding 30 seconds;
e.g. Mill motors.
Two immediate successive starts are admissible.

HHM 14