Está en la página 1de 4

DISEO DE ZAPATA AISLADA

DISEO DE LA ZAPATA (Z-2)

hf

t1

t2

DATOS GENERALES:
SECCION DE COLUMNA CARGA MUERTA: CARGA VIVA: CAPACIDAD PORTANTE DEL SUELO: PROFUNDIDAD DE DESPLANTE: PESO ESPECIFICO DEL TERRENO: RESISTENCIA DEL CONCRETO DE LA ZAPATA: SOBRECARGA DEL PISO: RESISTENCIA DEL ACERO: RECUBRIMIENTO DIAMETRO DE LAS VARILLAS DE REFUERZO: ALTURA A NIVEL DE PISO TERMINADO t1 = t2 = PD = PL = t = Df = t = f'c = s/c = Fy = R= v = hf= 0.30 0.25 12.50 5.80 1.63 1.50 1.85 175.00 300.00 4200.00 7.50 1.27 1.80 mts. mts. Tn. Tn. kg/cm2. mts. Tn/m3. kg/cm2. kg/m2. kg/cm2. cmt cm. mts.

ESFUERZO NETO DEL TERRENO " n ":


n = 12.67 Tn/m2

AREA DE LA ZAPATA " Azap ":


Azap = 1.44 m2 S' x T' = 1.210 x 1.210 m2 PARA CUMPLIR Lv1 = Lv2 T= S= 1.185 1.235 mts. Utilizar mts. Utilizar T= S= 1.200 mt 1.250 mt

USAR
Lv1 = Lv2 =

SxT
0.475

1.250

1.200

Df

0.475 REACCION NETA DEL TERRENO " Wnu ": Pu = 24.28 Tn Az = Wnu =

1.5 16.19

m2
Tn/m2

DIMENSIONAMIENTO DE LA ALTURA " h " DE LA ZAPATA POR PUNZONAMIENTO: CONDICION DE DISEO: Vc = Vu/ = (Pu-Wu.m.n)/. ( I ) TAMBIEN: Vc = 1.06(f'c)xboxd .( II ) I = II Formando una ecuacion de segundo Grado Entonces d = 0.1168 mt h = 20.45 cm usar =

0.85

h =

50.000 cm

dprom
VERIFICACION DE CORTANTE: Lv = Vdu = Vn = Vc =

0.410 m

0.475 1.32 1.55 35.93

mts. Tn. Tn. Tn > Vn

CONFORME

SENTIDO LONGITUDINAL:
DISEO POR FLEXION: Mu = b= ITERANDO: d = FACTOR DE REDUCCION DE DISEO IGUAL A 0.9 d = 0.334

2.28 125.00

Tn-m cm

0.90

Usar As =

1.48

cm2

a=

VERIFICACION DE ACERO MINIMO: Asmin = (temp).(b).(d)

Asmin = As =

9.23 9.23

cm2. cm2.

<

1.48

cm2.

USAR Asmin

CALCULO DE VARILLAS: A = AREA DE LA VARILLA A USAR EN cm2.

1.27

A = n = As/A = 7.26

cm2. VARILLAS VARILLAS

usar n =

r = RECUBRIMIENTO EN mts. USUALMENTE 0.075m. v = DIAMETRO DE LA VARILLA USADA EN mts. Separacion = ( S -2r - v ) / (n - 1) Separacion = 18.120 cm Usar Separacion = USAR: 18 7 cm VARILLAS 0 @

v =

18

cm

SENTIDO TRANSVERSAL:
Asl = Ast =
A = n = As/A = 6.97 9.23 cm2 cm2 cm2. VARILLAS VARILLAS 3

8.86

1.27

usar n =

r = RECUBRIMIENTO EN mts. USUALMENTE 0.075m. v = DIAMETRO DE LA VARILLA USADA EN mts. Separacion = ( S -2r - v ) / (n - 1) Separacion = 17.290 Usar Separacion = USAR: 17 7

v =

mts. mts. VARILLAS

17

cm

LONGITUD DE DESARROLLO DEL REFUERZO

Longitud disponible para cada barra


Ld = 40.00 cm

Para barras en Traccion :


Ab = Fc = Fy = db = Ld1 = Ld2 = Ld3 = 1.27 cm2 175.00 Kg/cm2 4200.00 Kg/cm2 1.272 cm 24.19 cm 30.44 cm 30.00 cm

Ld =

30.443 cm

Usar Ld =

24.354 cm

<

Ldisp =

40.000

cm

conforme

Transferencia de fuerza en la interfase de columna y cimentacion

a.- Transferencia al Aplastamiento sobre la columna


Pu = Pn = 24.28 Tn 37.35 Tn

Resistencia al Aplastamiento de la columna Pnb Pnb = Pn 111.5625 Tn

<

Pnb

conforme

b.- Resistencia al Aplastamiento en el concreto de la Cimentacion Pn = Xo = A2 = A1 = (A2/A1)^0,5 = Ao = Pnb = Pn 37.35 1.44 mt 1.728 mt 0.075 mt 4.8 0.15 223.125 Tn usar 2.00

<

Pnb

conforme

Dowells entre columna y cimentacion si Pn

<

Pnb

usar Asmin =

3.75 cm2 para zonas sismicas

También podría gustarte