Está en la página 1de 2

ejemplo_ Fellenius 290912

20 KN/m3
32
25 KN/m2
0.4

Gamma =
PHI =
c =
ru =
Reb
1
2
3
4
5
6

FS
FS =

b (m)
14
14
14
14
14
14

h (m)
5
14
21
23
21
13

alpha()
-15
3
16
28
38
57

l (m)
14.49
14.02
14.56
15.86
17.77
25.71
102.40

c.L a tan .( W cos ul)


Wsen
0.792

W (KN)
1400
3920
5880
6440
5880
3640

Wsen(a)
-362.3
205.2
1620.7
3023.4
3620.1
3052.8
11159.8

Wcos(a)
1352.3
3914.6
5652.2
5686.2
4633.5
1982.5

u (KN/m2)
40
112
168
184
168
104

Wcos(a)-u*l
772.5
2344.5
3205.4
2768.7
1648.8
-690.8
10049.1

Gamma =
PHI =
c =
ru =
FS(asum) =
Reb
1
2
3
4
5
6

20 KN/m3
32
25 KN/m2
0.4
1.009
b (m)
14
14
14
14
14
14

h (m)
5
14
21
23
21
13

alpha()
-15
3
16
28
38
57

W (KN)
1400
3920
5880
6440
5880
3640

Wsen(a)
-362.3
205.2
1620.7
3023.4
3620.1
3052.8
11159.8

1
sec

FS
c' b W (1 ru ) tan '

tan tan '


Wsen
1

FS

(I)
FS =
DIFER =

1.009
0.000

(II)

(I)
874.9
1819.7
2554.5
2764.5
2554.5
1714.7

(II)
1.241
0.970
0.883
0.852
0.855
0.940

(I) * (II)
1086.0
1764.9
2256.7
2355.3
2184.6
1611.4
11259.0