Operation Manual
EPVC_Large
Diagnostic / Monitoring / Adjusting tools for following excavators. Hitachi EX-1 (550), EX-3 (400 to 600), EX-5 (400 to 800), ZAXIS (450 to 850) Fiat Hitachi FH450-3, EX455, EX456
EPVC_Mid
Diagnostic / Monitoring / Adjusting tools for following excavators. Hitachi EX-1 (USE series), EX-2 (60 to 300), EX-3 (60 to 310) EX-5 (60 to 370), ZAXIS (70 to 380) Fiat Hitachi FH-2 series, FH-3 series, EX series (less than 40 tons)
EPVC_Mini
Diagnostic / Monitoring / Adjusting tools for following excavators. Hitachi EX33Mu & EX58Mu
HMS_LargeMid
Monitoring data download / Data logger setting following excavators. Hitachi ZAXIS (70 to 850) John Deere C series (80C to 800C)
MIC_Mining
Monitoring data download / Data logger setting / Monitoring / Diagnostic following excavators.
Hitachi EX1200-5/5C, EX1900-5, EX2500-1/5, EX3500-1/2/3, EX3600-5, EX5500-5
EPVC_LARGE
Operation Manual
Hitachi Construction Machinery Co. Ltd.
NOTE This manual is based on Hitachi ZX series. Screen / Function / Procedure are vary by model.
1. Necessary Tools & Cable Connection 2. MODE OPERATION MODE 3. Operation Mode How to Start Dr.ZX with Operation Mode 4. Operation Mode Self-Diagnostic 5. Operation Mode Monitoring 6. Operation Mode Special Function (WU Deactivation) 7. Operation Mode Special Function (ECO Deactivation) 8. Operation Mode Special Function (Pump Adjustment) SERVICE MODE 9. Service Mode How to Start Dr.ZX with Service Mode 10. Service Mode Learning Data Display 11. Service Mode Monitor Panel LCD Control 12. Service Mode Parameter Change 13. Service Mode Act/Deact of Parameters STAND ALONE MODE 14. Stand Alone 15. Stand Alone 16. Stand Alone 17. Stand Alone
- How to Start Dr.ZX with Stand Alone Mode Change Password View Manuals Play Recorded Data
Dr.ZX must be installed. Hitachi recommends following models. SONY Clie PEG-TJ25 PalmOne Inc. m125 / 130 / 500 / 505 / 515 Tungsten T2 / T3 / C Cable connection Dr.ZX cable
For SONY Clie PEG-TJ25 Purchase from CPD. P/no. is 4629330 (Hitachi unique parts). For PalmOne PDAs Purchase from local market. Product name is HotSync serial
This is Hitachi unique part. Make an order to your parts ordering channel. Hitachi part no. is 4476512.
Serial cable
Palm OS PDA
Palm
Serial cable
to
Dr.ZX cable
Equipment
2. Mode
EPVC_Large
NOTE For non-current models (such as EX-2/-3/-5), operation & stand-alone mode will apply Self-Diagnostic Monitoring / Recording Sensor out-put signal WU (Warming-up function) Deactivation ECO (Economy function) Deactivation Pump (Angle sensor) Adjustment Start Dr.ZX with Operation Mode
Check Engine Learning Data Monitor Engine Speed & Hydraulic Oil Temperature Change Parameter(s), such as follows Engine RPM Auto-Lub. Interval Pump Max. Displacement Pump Max. Torque Pump Cut-off Pressure Activate or Deactivate Changed Parameters
Change Password Replay Recorded Monitoring Data Refer Instant Operation Manual
Start Dr.ZX.
Select EPVC_Large.
Self - Diagnostic
Special Function
OFF
Stamp
Main switch is vary by Palm model. Above shows Palm m500 / 505 / 515.
Tap of EPVC_Large.
Tap START.
Check model. If model is correct, tap correct, if not tap ESC and contact to your dealer.
Error(s) detected.
are
Tap ESC.
Carry Retry.
out
No detected.
error
Message display.
will
Tap of Self-Diagnostic.
If Dr.ZX could not detect any error(s), above message will display. Tap ESC.
(d) Retry
Error code(s) that detected will display to Palm. Tap ESC for retry.
If Dr.ZX could not detect any error(s), above message will display. Tap ESC.
If Dr.ZX still detect any error(s) , error code(s) will display. Tap Details for check error(s).
Message will show meanings of each code, and corrective action. Tap Next for view additional information or other code.
manuals
for
Start recording.
recorded to data
NOTE If you did not enter model code & equipment serial no., you cant record monitoring data to Palm.
TIP You can use keyboard to enter model code & serial no. by tap abc or 123 on GRAFFITI area. Tap of Monitor Display Tap columns and enter model code & serial no. If you did not enter model code & serial no., you cant record monitoring data.
(c) Tap OK
Selected item
After enter model & serial no., tap OK. If you dont need to record monitoring data, no need to enter model code & serial no. Just tap OK.
Tap of item you want monitor. You can monitor four items in once. Clear item(s). selected
Item(s) will display. Screen will vary by selected items. Tap Hold for pause data. If you want quit, tap ESC.
(h) Recording
Tap Record for record monitoring data. Dr.ZX will record data for three (3) seconds.
NOTE If you did not enter model code & serial no., Record button shall not appear.
Tap data bank (figure) that you want to store recorded data.
If selected data bank already has data, above screen will appear. Tap OverWrite for store recorded data, tap ESC for back to previous menu.
If selected data bank is empty, above screen will display. Tap Write for store recorded monitoring data.
(l) Confirmation
TIP You can use keyboard to enter comment. Tap abc on GRAFFITI are.
After data stored, confirmation screen will display. Tap ESC to quit, or if you want enter comment, tap Comment.
Tap comment column, and enter comment. After entering, tap OK.
how
to
repaly
WU Function. WU stands for Warming-Up. This function is, when start engine while hydraulic oil temperature is less than zero (0) Celsius, computer will increase low idle rpm for warm hydraulic oil quickly.
Tap of WU Deactivation..
Tap Execute for Deactivation. If you want back to previous menu, tap ESC.
(d) Confirmation
After deactivation, above message will display. Tap ESC for quit.
NOTE WU (Warming-up function) will re-activate when key switch is turned OFF.
ECO Function ECO stands for ECOnomy. This function is, when all levers are in neutral position, computer will reduce engine rpm to 1600min-1 gradually. If any lever(s) are operated, engine rpm will back.
Tap Execute for Deactivation. If you want back to previous menu, tap ESC.
(d) Confirmation
After deactivation, above message will display. Tap ESC for quit.
NOTE ECO (Economy function) will re-activate when key switch is turned OFF.
Start engine.
Switch on Palm.
Start Dr.ZX.
Start EPVC_Large.
From previous
Adjust sensors.
angle
Main switch is vary by Palm model. Above shows Palm m500 / 505 / 515.
(c) Remove A (angle) sensors from pump Engine Loose Bolts Pump-2 sensor Pump-1 sensor
Remove two (2) angle sensors from pump. When removing, take care not to lose internal spacer & fastener spring.
Pump-2 sensor
Pump-1 sensor
Connect harness
to
OFF
Stamp
Main switch is vary by Palm model. Above shows Palm m500 / 505 / 515.
Tap of EPVC_Large.
Tap START.
Check model. If model is correct, tap correct, if not tap ESC and contact to Hitachi.
NOTE After tap Max. Disp. Holding, wait more than five (5) seconds. Computer will operate main pump to maximum displacement position.
Punch Mark
Feedback Shaft
(s) Apply grease Apply a film of grease to the surface of fastener spring, and install I into the cavity on the feedback shaft.
Fastener Spring
ZX450 & ZX500 Angle Sensors Location Pump-2 sensor Pump-1 sensor Pump-2 sensor
Pump-1 sensor
Harness Side
Harness Side
Harness Side
Harness Side
Switch on Palm.
Start Dr.ZX.
Select EPVC_Large.
Start mode.
service
Confirm model.
Service menu.
mode
Change Parameter.
NOTE Wait more than ten (10) seconds, after key switch is turned off. Stamp
ON
Main switch is vary by Palm model. Above shows Palm m500 / 505 / 515.
Tap of EPVC_Large.
Tap START.
Check model. If model is correct, tap correct, if not tap ESC and contact to Hitachi.
Tap Rechecked.
Position display/.
will
Monitor Panel
Service menu.
mode
Select Execute.
Select Execute.
Tap Disp for allow to display information, and tap NoDisp for not allow to display information.
(c) Execute
(c) Quit
If execution is completed, above message will display. Tap ESC for quit.
Confirmation screen.
Tap Execute.
End message.
Tap ESC.
NOTE You have to carry out Act/Deact of Parameters function after changing parameters. Otherwise changed parameter(s) shall not transfer to equipment main computer.
and
enter
TIP You can use keyboard to enter figures. Tap 123 on GRAFFITI are.
Tap Deact.
or
(c-1) Deactivation
14. Stand Alone Mode - How to Start Dr.ZX with Stand Alone Mode (1/2)
Switch on Palm. Start Dr.ZX. Start EPVC_Large. Main screen. Change password
View manuals.
14. Stand Alone Mode - How to Start Dr.ZX with Stand Alone Mode (2/2)
(a) Switch ON Palm (b) Start Dr.ZX
Main switch is vary by Palm model. Above shows Palm m500 / 505 / 515.
Tap of EPVC_Large.
TIP You can use keyboard to enter password. Tap abc on GRAFFITI are. Tap Password. Enter current password. password is zx2000. Default
engine mode
NOTE To play recoded data, you have to record monitoring data before.
Tap number of data bank that you want to play, and tap Play Back.
EPVC_MID
Operation Manual
Hitachi Construction Machinery Co. Ltd.
NOTE This manual is based on Hitachi ZX series. Screen / Function / Procedure are vary by model.
1. Necessary Tools & Cable Connection 2. MODE OPERATION MODE 3. Operation Mode How to Start Dr.ZX with Operation Mode 4. Operation Mode Self-Diagnostic 5. Operation Mode Monitoring 6. Operation Mode Special Function (WU Deactivation) 7. Operation Mode Special Function (ECO Deactivation) SERVICE MODE 8. Service Mode How to Start Dr.ZX with Service Mode 9. Service Mode Learning Data Display 10. Service Mode Monitor Panel LCD Control 11. Service Mode Parameter Change STAND ALONE MODE 12. Stand Alone 13. Stand Alone 14. Stand Alone 15. Stand Alone
- How to Start Dr.ZX with Stand Alone Mode Change Password View Manuals Play Recorded Data
Dr.ZX must be installed. Hitachi recommends following models. SONY Clie PEG-TJ25 PalmOne Inc. m125 / 130 / 500 / 505 / 515 Tungsten T2 / T3 / C Cable connection Dr.ZX cable
For SONY Clie PEG-TJ25 Purchase from CPD. P/no. is 4629330 (Hitachi unique parts). For PalmOne PDAs Purchase from local market. Product name is HotSync serial
This is Hitachi unique part. Make an order to your parts ordering channel. Hitachi part no. is 4476512.
Serial cable
Palm OS PDA
Palm
Serial cable
to
Dr.ZX cable
Equipment
2. MODE
Dr.ZX
NOTE For non-current models (such as EX-2/-3/-5), operation & stand-alone mode will apply Self-Diagnostic Monitoring / Recording Sensor out-put signal WU (Warming-up function) Deactivation ECO (Economy function) Deactivation Start Dr.ZX with Operation Mode
Check Engine Learning Data Monitor Engine Speed & Hydraulic Oil Temperature Change Parameter(s), such as follows Engine RPM Auto-Lub. Interval Pump Max. Displacement Pump Max. Torque Pump Cut-off Pressure
Change Password Replay Recorded Monitoring Data Refer Instant Operation Manual
Start Dr.ZX.
Select EPVC_Mid.
Self - Diagnostic
Special Function
Stamp
Main switch is vary by Palm model. Above shows Palm m500 / 505 / 515.
Tap of EPVC_Mid.
Tap START.
Check model. If model is correct, tap correct, if not tap ESC and contact to your dealer.
Error(s) detected.
are
Tap ESC.
Carry Retry.
out
No detected.
error
Message display.
will
Tap of Self-Diagnostic.
If Dr.ZX could not detect any error(s), above message will display. Tap ESC.
(d) Retry
Error code(s) that detected will display to Palm. Tap ESC for retry.
If Dr.ZX could not detect any error(s), above message will display. Tap ESC.
If Dr.ZX still detect any error(s) , error code(s) will display. Tap Details for check error(s).
Message will show meanings of each code, and corrective action. Tap Next for view additional information or other code.
manuals
for
Start recording.
recorded to data
NOTE If you did not enter model code & equipment serial no., you cant record monitoring data to Palm.
TIP You can use keyboard to enter model code & serial no. by tap abc or 123 on GRAFFITI area. Tap of Monitor Display Tap columns and enter model code & serial no. If you did not enter model code & serial no., you cant record monitoring data.
(c) Tap OK
Selected item
After enter model & serial no., tap OK. If you dont need to record monitoring data, no need to enter model code & serial no. Just tap OK.
Tap of item you want monitor. You can monitor four items in once. Clear item(s). selected
Item(s) will display. Screen will vary by selected items. Tap Hold for pause data. If you want quit, tap ESC.
(h) Recording
Tap Record for record monitoring data. Dr.ZX will record data for three (3) seconds.
NOTE If you did not enter model code & serial no., Record button shall not appear.
Tap data bank (figure) that you want to store recorded data.
If selected data bank already has data, above screen will appear. Tap OverWrite for store recorded data, tap ESC for back to previous menu.
If selected data bank is empty, above screen will display. Tap Write for store recorded monitoring data.
(l) Confirmation
TIP You can use keyboard to enter comment. Tap abc on GRAFFITI are.
After data stored, confirmation screen will display. Tap ESC for quit, or if you want enter comment, tap Comment.
Tap comment column, and enter comment. After entering, tap OK.
how
to
replay
WU Function. WU stands for Warming-Up. This function is, when start engine while hydraulic oil temperature is less than zero (0) Celsius, computer will increase low idle rpm for warm hydraulic oil quickly.
Tap of WU Deactivation..
Tap Execute for Deactivation. If you want back to previous menu, tap ESC.
(d) Confirmation
After deactivation, above message will display. Tap ESC for quit.
NOTE WU (Warming-up function) will re-activate when key switch is turned OFF.
ECO Function ECO stands for ECOnomy. This function is, when all levers are in neutral position, computer will reduce engine rpm to 1600min-1 gradually. If any lever(s) are operated, engine rpm will back.
Tap Execute for Deactivation. If you want back to previous menu, tap ESC.
(d) Confirmation
After deactivation, above message will display. Tap ESC for quit.
NOTE ECO (Economy function) will re-activate when key switch is turned OFF.
Switch on Palm.
Start Dr.ZX.
Select EPVC_Mid.
Start mode.
service
Confirm model.
Service menu.
mode
Change Parameter.
Stamp
NOTE Wait more than ten (10) seconds, after key switch is turned off.
Main switch is vary by Palm model. Above shows Palm m500 / 505 / 515.
Tap of EPVC_Mid.
Tap START.
Check model. If model is correct, tap correct, if not tap ESC and contact to Hitachi.
Tap Rechecked.
Position display/.
will
NOTE Boom Angle Sensor Correction Value & Arm Angle Sensor Correction Value are used for equipment which has lifting load monitor (option item).
Monitor Panel
Service menu.
mode
Select Execute.
Select Execute.
(c) Execute
(c) Quit
Tap Disp for allow to display information, and tap NoDisp for not allow to display information.
If execution is completed, above message will display. Tap ESC for quit.
Confirmation screen.
Tap Execute.
End message.
Tap ESC.
and
enter
TIP You can use keyboard to enter figures. Tap 123 on GRAFFITI are.
12. Stand Alone Mode - How to Start Dr.ZX with Stand Alone Mode (1/2)
Switch on Palm. Start Dr.ZX. Start EPVC_Large. Main screen. Change password
View manuals.
12. Stand Alone Mode - How to Start Dr.ZX with Stand Alone Mode (2/2)
(a) Switch ON Palm (b) Start Dr.ZX
Main switch is vary by Palm model. Above shows Palm m500 / 505 / 515.
Tap of EPVC_Large.
TIP You can use keyboard to enter password. Tap abc on GRAFFITI are. Tap Password. Enter current password. password is zx2000. Default
engine mode
NOTE To play recoded data, you have to record monitoring data before.
Tap number of data bank that you want to play, and tap Play Back.
EPVC_Mini
Operation Manual
Hitachi Construction Machinery Co. Ltd.
NOTE This manual is based on Hitachi ZX series. Screen / Function / Procedure are vary by model.
1. 2. 3. 4. 5. 6. 7. 8. 9.
Necessary Tools & Cable Connection Function How to Start EPVC_Mini Displaying & Deleting Fault Code History Troubleshooting Fault Codes List Zone check Monitoring Current Correction
Dr.ZX must be installed. Hitachi recommends following models. SONY Clie PEG-TJ25 PalmOne Inc. m125 / 130 / 500 / 505 / 515 Tungsten T2 / T3 / C Cable connection Dr.ZX cable
For SONY Clie PEG-TJ25 Purchase from CPD. P/no. is 4629330 (Hitachi unique parts). For PalmOne PDAs Purchase from local market. Product name is HotSync serial
This is Hitachi unique part. Make an order to your parts ordering channel. Hitachi part no. is 4476512.
Serial cable
Palm OS PDA
Palm
Serial cable
to
Dr.ZX cable
Equipment
2. Function
EPVC_Mini Fault Code Disp & Del
This function will show or delete fault code & operation history that memorized in controller. Controller can keep 59 records. If more than 59 fault code and/or operation occurred, controller would overwrite latest information to oldest record. Computer will
Troubleshooting This function will display fault code that controller is sensing. If any trouble is occurring, PDA will shoe fault code. If PDA could not detect any fault, PDA will display 00 on each items.
ZONE Check This function will display current boom & swing position.
Monitor Display This function allows monitoring item. You can check four items in once.
Current Correction This function allows to correct following items (a) Boom & swing deceleration currency (adjusting range is +/- 100 mA) Use this function when you feel deceleration speed is too slow. (b) Boom stop position (adjusting range is +/- 20 degree) Use this function when you feel boom stop position it too close or far.
Tap of EPVC_Mini.
Software version will display. Tap Start to continue. Tap Exit to back to main menu.
Equipment information will display. Tap OK to continue. Tap Model Menu to back to software version display screen.
are
Tap Info.
Tap Delete
Tap Exit
If there arent any fault recorded in controller, above message will display. Tap Exit to
(f) Meanings
Tap Info.
Meaning of each code will display. Tap or to check other code. Tap Exit to back to fault code list.
Tap Delete. This will clear all fault code history recording in controller.
When clearing is finished, end message will display. Tap OK to back to item menu.
5. Troubleshooting
(a) Item menu (b)List of fault codes (c) Check meaning of fault code
If any faults are occurring, fault code will display. If no faults are occurring, code will display as 00. Tap HOLD to check content of fault.
Tap Info. to show meaning of each code. Tap Exit to back to item menu.
Current boom & swing position will display. Tap Exit to back to item menu.
BJL1
BJL2
B1
B4
B7
BJL6
B3
B5
B6
Code BJL B1 B2 B3 B4
Description Zone judging line by boom angle. Boom up critical zone Boom up stop zone Boom up deceleration zone Boom up deceleration zone (front of operator)
Code B5 B6 B7
Description Boom up deceleration zone Boom up normal zone Boom up deceleration zone (Height limit)
S6
SJL4
S4
Description Zone judging line by boom angle. Zone judging line by swing angle. Right swing critical zone Right swing stop zone
Code S3 S4 S5 S6
Description Right swing deceleration zone Right swing deceleration zone Right swing normal zone Right swing deceleration zone (End of right swing)
8. Monitoring
(a) Item menu (b) Item menu
Selected item
Tap of item you want monitor. You can monitor four items in once. Clear item(s). selected Number of selected item(s).
(d) Monitoring
Item(s) that you selected will display (information will vary by item). Tap Hold to pause data, and tap Exit to quit monitoring.
Tap figures you want to change, and tap OK. To find figures tap or . If you selected boom stop position unit will be degree.
TIP You can use keyboard to enter password. Tap abc on GRAFFITI area.
Confirm figures you changed, and tap OK. If you want to correct, tap Exit.
To send figures to computer in equipment, you have to enter password. Tap password area, and enter FF.
HMS_LargeMid
Operation Manual
Hitachi Construction Machinery Co. Ltd.
NOTE This manual is based on Hitachi ZX series. Screen / Function / Procedure are vary by model. Downloaded data will belong to customer. Shall not disclose data to third parties, or to even internal personnel, if they arent authorized.
1. Necessary Tools & Cable Connection 2. Function ICX INITIALIZING 3. ICX Initializing How to start Dr.ZX 4. ICX Initializing General Flow 5. ICX Initializing Set Time Difference from GMT 6. ICX Initializing Set Local Time 7. ICX Initializing Synchronize Service-meter 8. ICX Initializing Model Code & Serial No. Setting DOWNLOADING 9. Data Downloading How to Start Dr.ZX 10. Data Downloading Download 11. Data Downloading Check Downloaded Data ICX DIAGNOSIS 12. ICX Self Diagnoses Flow 13. ICX Self Diagnoses Operation CHANGE PASSWORD 14. Change Password Flow 15. Change Password Operation
Dr.ZX must be installed. Hitachi recommends following models. SONY Clie PEG-TJ25 PalmOne Inc. m125 / 130 / 500 / 505 / 515 Tungsten T2 / T3 / C Cable connection Dr.ZX cable
For SONY Clie PEG-TJ25 Purchase from CPD. P/no. is 4629330 (Hitachi unique parts). For PalmOne PDAs Purchase from local market. Product name is HotSync serial
This is Hitachi unique part. Make an order to your parts ordering channel. Hitachi part no. is 4476512.
Serial cable
Palm OS PDA
Palm
Serial cable
to
Dr.ZX cable
Equipment
2. Function
HMS_LargeMid
NOTE HMS_LargeMid only apply to ZX & C series excavators. ICX Initializing Set Time Difference from GMT Set Local Time Synchronize Service-Meter Reading Set Model Code & Serial No. Clear ICX Internal Memory Perform this function when following cases occur. (a) Deliver new equipment to customer. (b) Replace ICX. (c) Error on downloaded data.
Perform this function when you want to download data from equipment.
Change Password
Start Dr.ZX.
Select HMS_LargeMid .
Select Set-ICX.
Enter password.
Tap Start.
Stamp
Hitachi ZAXIS70, 80, 75US, 75UR, 135US, 225US John Deere 80C, 135CRTS, 225CCL RTS
Connect
Hitachi ZAXIS70, 80, 75US, 75UR, 135US, 225US John Deere 80C, 135CRTS, 225CCL RTS
Main switch is vary by Palm model. Above shows Palm m500 / 505 / 515.
Tap of HMS_LargeMid.
Tap of Set-ICX.
TIP You can use keyboard to enter password. by tap abc or 123 on GRAFFITI area. Tap entering column, and enter password. Default password is zx2000. After enter password, tap OK.
Tap of ICX Initial Setting. If ICX Initial Setting is not in menu, tap or to changeover menus.
Tap of Enter Time Diff. from UTC. If item is not in menu, tap or to changeover menus.
Check current time difference. If it is correct tap ESC, if you want to correct, tap Correct. Time difference table is on next page.
Tap OK
NOTE Please carry out this setting, after set time difference from GMT.
Tap of Enter Date and Time. . If item is not in menu, tap or to changeover menus.
TIP You can use keyboard to enter password. by tap abc or 123 on GRAFFITI area. Tap entering column current local time. and enter
If local time is correct, tap OK for set. If not correct, tap NG to re-enter.
Tap OK
Tap of Initial Hour Meter Setting. . If item is not in menu, tap or to changeover menus.
If figures are difference, tap Set for synchronizing. ICX will set it hour meter as external hour meter.
Tap OK.
Tap of Enter Model and Serial No.. If item is not in menu, tap or to changeover menus.
Even if model code & Serial no. are correct, tap Correct.
NOTE-1 If PIN code is HCM 1G600 L 00123456 Model code is 1G6. Serial no. is 123456.
TIP You can use keyboard to enter password. by tap abc or 123 on GRAFFITI area.
If model code and/or serial no. are incorrect, tap column, and enter correct model code and/or serial no. Equipment model code & serial no. are stamp on name plate.
NOTE-2 When entering model code, you have to add 0 (zero) in front of model code. For example, if model code is 1G6, you have to enter 01G6.
Tap OK
When initialize ICX, you have to clear ICX internal memory. Otherwise you cant view data in some cases.
(j) Tap OK
NOTE Shall not download immediately after memory clear, because data is empty (Dataviewer could not recognize empty data as downloaded data. Operate equipment at least an hour, and download data.
Start Dr.ZX.
Select HMS_LargeMid .
Download Menu
Stamp
Connect
Main switch is vary by Palm model. Above shows Palm m500 / 505 / 515.
Tap of HMS_LargeMid.
Palm Operation (a) Select Data Download (b) Downloading (c) Quit download
Download will start automatically after selecting data download. If you want to cancel download, tap Cancel.
Download will start automatically after selecting data download. If you want to cancel download, tap Cancel.
Tap of SaveDataCheck.
Start Dr.ZX.
Select HMS_LargeMid .
Select Set-ICX.
Enter password.
Tap Start.
are tap
Stamp
Connect
Main switch is vary by Palm model. Above shows Palm m500 / 505 / 515.
Tap of HMS_LargeMid.
Tap of Set-ICX.
TIP You can use keyboard to enter password. by tap abc or 123 on GRAFFITI area. Tap entering column, and enter password. Default password is zx2000. After enter password, tap OK.
Tap of ICX Initial Setting. If ICX Initial Setting is not in menu, tap or to changeover menus.
If errors have not detected, above message will display. Tap ESC to quit.
If any errors have detected, error code will display. Tap Retry for confirmation.
If still errors have detected, error code will display. Tap Detail to check content of each error.
Content of error will display. Tap or to changeover error. Tap ESC to quit.
Start Dr.ZX.
Select HMS_LargeMid .
Select Set-ICX.
Enter password.
Tap Password.
Change password.
Stamp
Connect
Main switch is vary by Palm model. Above shows Palm m500 / 505 / 515.
Tap of HMS_LargeMid.
Tap of Set-ICX.
TIP You can use keyboard to enter password. by tap abc or 123 on GRAFFITI area. Tap entering column, and enter password. Default password is zx2000. After enter password, tap OK.
TIP You can use keyboard to enter password. Tap abc on GRAFFITI are. Enter current password. password is zx2000. Default
MIC Mining
Super Large Excavators (EX1200-5 & up) Monitoring System
Operation Manual
1. Necessary Tools & Cable Connection 2. Connector Location on Equipment for Monitoring 3. How to start MIC_Mining 4. Using CODE by Situation CODE 5. Code SAD-P 6. Code SAI-P 7. Code DDL-P 8. Code MEC-P 9. Code SEC-P 10. Code SEC-P
Dr.ZX must be installed. Hitachi recommends following models. SONY CLIe PEG-TJ25 PalmOne Inc. m125 / 130 / 500 / 505 / 515 Tungsten T2 / T3 / C
Purchase from local market. Provide cable that adapt to your Palm.
This is Hitachi unique part. Make an order to your parts ordering channel. Hitachi part no. is 4486988.
Palm
Serial cable
Download cable
Equipment
on is
Switch on a PDA.
Start Dr.ZX
Start MIC_Mining.
Tap of EPVC_Mini.
SAI-P
DDL-P
MEC-P
Troubleshooting
SEC-P
CMC-P
Flow of this code Set time difference from GMT. Set local date & time. Set service reading. meter Check equipment serial no. recorded in Data logger.
Confirmation
Tap to set time difference between GMT. List of time difference is at Code SAD-P 9/9.
in
tools
(04) Date & Time adjustment TIP You can use keyboard to enter password. Tap abc or 123 on GRAFFITI area.
Enter name of person who will set date & time at name column, and enter clock at work code column.
Tap Next.
Date & time current recorded in DLU will display. If you have to adjust, tap Change, if no need to change, tap Set.
Tap Date.
Tap Today. Date & year will set automatically. Before setting date, confirm date on Palm is same as local.
Tap Time.
Message will display. Tap Ok to set date & time. Tap Back to correct date & time.
Main screen
in
tools
Enter name of person who will set service meter at name column, and enter run at work code column.
Tap Next.
Message will display. Tap Ok to set service meter reading. Tap Back to correct service meter reading.
Main screen
(27) Serial no. check TIP You can use keyboard to enter password. Tap abc or 123 on GRAFFITI area.
in
tools
Enter name of person who will check serial no. at name column, and enter serial-no at work code column.
Tap Next.
If serial no. does not match to equipment, carry out SAI-p. Tap Set.
Tap Ok.
(32) Confirmation
Even serial no. is correct, please carry out memory clear, when deliver new equipment to customer. Otherwise data will corrupt.
Tap Ok.
Main screen
Confirm every information on this screen are correct. If not, please re-adjust. If serial no. doesnt match, perform SAI-P.
Flow of this code Set no. equipment serial Clear memory in data logger. Set time difference from GMT. Set local date & time.
meter
Main screen
in
tools
(04) Serial no. correcting TIP You can use keyboard to enter password. Tap abc or 123 on GRAFFITI area.
Enter name of person who will set serial no. at name column, and enter serial-no at work code column.
Tap Next.
If serial no. you entered is correct, tap Ok. If you want to re-enter serial no., tap Back.
Tap Yes to clear DLU internal memory. Otherwise data will corrupt.
Tap Ok.
Tap to set time difference between GMT. List of time difference is at Code SAI-P 9/9.
(15) Date & Time adjustment TIP You can use keyboard to enter password. Tap abc or 123 on GRAFFITI area.
in
tools
Enter name of person who will set data & time at name column, and enter clock at work code column.
Tap Next.
Date & time current recorded in DLU will display. If you have to adjust, tap Change, if no need to change, tap Set.
Tap Date.
Tap Today. Date & year will set automatically. Before setting date, confirm date on Palm is same as local.
Tap Time.
Message will display. Tap Ok to set date & time. Tap Back to correct date & time.
Main screen
in
tools
Enter name of person who will set service meter at name column, and enter run at work code column.
Tap Next.
Message will display. Tap Ok to set service meter reading. Tap Back to correct service meter reading.
Main screen
(36) Confirmation
(37) Confirmation
(38) Confirmation
Confirm every information on this screen are correct. If not, please re-adjust.
Flow of this code Enter name of person who will attempt to donwload. Set time difference from GMT. Start download. End message display will
NOTE Downloaded data will belong to customer. Shall not disclose data to third parties, or to even internal personnel, if they arent authorized.
Tap name column, and enter name who attempt to download. If you already registered, tap to find your name.
Tap to set time difference between GMT. List of time difference is at Code DDLP 3/5.
(03) Download
(04) Download
(05) Download
Tap Next.
Do not terminate palm application while downloading. Otherwise data will corrupt.
Do not change key switch to any position while downloading. Otherwise data will corrupt.
on is
Switch on a PDA.
Flow of this code Select SettingAdjustment menu. in Enter name & code serial-no. work Clear memory.
Main screen
in
tools
(04) Memory clear TIP You can use keyboard to enter password. Tap abc or 123 on GRAFFITI area.
Enter name of person who will clear internal memory at name column, and enter serial-no at work code column.
Tap Next.
Tap Set.
Tap Ok.
Tap Yes
Tap Ok.
Flow of this code Select SystemCheck in tools menu. Select Conditions is System check menu. Select Sensor Faults in .system check menu.
Main screen
Equipment conditions will display/ Check figure(s) will change while operating. Information will vary by equipment models.
If there is a NG on sensor, there will be communication fault in sensor and/or sensor line. Tap or to changeover sensor.
Flow of this code Select SystemCheck in tools menu. Select Conditions is System check menu.
Main screen
Communication condition will display. If communication condition is not OK, please check line between controller and DLU.