Documentos de Académico
Documentos de Profesional
Documentos de Cultura
Installation Guide
Content
Safety Information 1. Information About the Installation 2. Installing the BBU in the APM30 3. Installing the BBU in the APM30H 4. Installing the BBU in the APM30 (+24 V) 5. Installing the BBU in the 19-Inch Cabinet 6. Installing the BBU on the Wall 7. Installing the BBU in the PS4890 Cabinet 8. Installing the BBU in the OMB Cabinet 9. Installing the BBU in the TMC 10. Installing the BBU in the TMC11H 11. Checking the Power-On Status of the BBU 12. Reference
2 3 8 15 17 19 23 28 33 39 41 42 43
Safety Information
Following All Safety Precautions
Before any operation, read the instructions and precautions in this document carefully to minimize the possibility of accidents. The Danger, Caution, and Note items in the documents do not cover all the safety precautions that must be followed. They only provide the generic safety precautions for operations. When operating Huawei products and equipment, you must comply with safety precautions and special safety instructions related to corresponding equipment provided by Huawei. The safety precautions in the document are related to only Huawei products. Huawei is not liable for any consequence that results from the violation of universal regulations for safety operations and safety codes on design, production, and equipment use.
Symbols
This symbol indicates that casualty or serious accident may occur if you ignore the safety instruction. This symbol indicates that serious or major injury may occur if you ignore the safety instruction. This symbol indicates that the operation may be easier if you pay attention to the safety instruction.
Safety of Personnel
The high voltage power supply provides power for running the system. Direct contact with the high voltage power supply or contact through damp objects may result in fatal danger. Non-standard and improper high voltage operations may result in fire and electric shock. In a thunderstorm, do not perform operations on high voltage and AC power supply facilities or on a steel tower and mast. Ground the device before powering on the device. Otherwise, the personnel and device are in danger. Power off the device before performing operations on the power supply equipment. High power radio-frequency signals are harmful to human body. Before installing or maintaining an antenna on a steel tower or mast with a large number of transmitter antennas, the operator should coordinate with all parties to ensure that the transmitter antennas are shut down. When handling optical fibers, do not stand close to, or look into the optical fiber outlet with unaided eyes. Protect yourself when drilling holes. Flying dust may hurt your eyes or you may inhale the dust. Power off the batteries before connecting the cables to the batteries. Otherwise, casualties may occur. When working at a height, be cautious about falling objects.
Device Safety
Check the electrical connection of the device before operation and ensure that the device is reliably grounded. The static electricity generated by the human body may damage the electrostatic sensitive components on the circuit board, such as the large-scale integrated circuit (LIC). Wear an ESD wrist strap or ESD gloves when performing the operation. When working on batteries, take measures to prevent short circuits in the batteries and electrolyte spill/loss. The electrolyte may erode metal and boards, or even cause rust of the equipment or short circuits in the boards. The NodeB must be powered on within one week after installation.
Insulated screwdriver
Cross screwdriver
Straight screwdriver
Adjustable wrench
Socket wrench
Torque wrench
Wire cutter
Rubber hammer
Claw hammer
Cable peeler
Percussion drill
Heat gun
Level bar
Multimeter
Vacuum cleaner
1.APM30
BBU
BBU
3.TMC
4.TMC11H
BBU
BBU
5.APM30 (+24V
BBU BBU
7. In OMB cabinet
9. On the Wall
Board
Full Configuration 2 4
Installation Slot
Remarks
WMPT WBBP
S6 and S7 S0 to S3
Preferentially configured in Slot 7. Preferentially configured in Slot 3, then Slot 2, at last Slot 0,1. Preferentially configured in PWR2. Only in the FAN slot. Preferentially configured in Slot 4, 5. Preferentially configured in Slot 4. Preferentially configured in Slot 4. Preferentially configured in PWR1.
2 1 5
2 2 1
Power System BBU Power Cable E1 surge protection transfer cable E1 Cable Monitoring Cable Alarm Cable CPRI Optical FE cable FE surge protection transfer cable
Procedure
NO.
Cable
Installation Position From... To ... PWR on BBU INSIDE on UELP Transmission equipment MON1on BBU CPRI on RRU
1 2 3 4 5
LOAD3 on PDU E1/T1 on WMPT OUTSIDE on UELP TX/RX on APMI CPRI on BBU
PDU
BBU M6 bolt
2 Slide the BBU case into the cabinet. 3 Check the DIP switches (see appendix).
Installing cables
1. Install power cable.
Connect the OT terminal of the power cable to the LOAD3 terminal of the PDU, and then fix the 3V3 connector of the power cable to the PWR port on the BBU.
PWR
The power cable is to be made depending on field requirements.
2. Install optical cables. Connect one end of the optical cable to CPRI0, CPRI1, or CPRI2 on the WBBP. Then, connect the other end to the RRU. Insert the optical module into CPRI0, CPRI1, or CPRI2. Turn outwards the puller on the optical module.
Remove the dustproof caps from the optical connectors. Insert the optical connector at one end of the CPRI optical cable into the optical module. lead the CPRI optical cable out of the cabinet along the left side of the cabinet.
Wrap the fiber tail with the winding pipe till the first cable tie.
Connect the fiber tails labeled 1A and 1B to the CPRI_W port on the RRU. Connect the fiber tails labeled 2A and 2B to one of the CPRI0 to CPRI5 ports on the WMPT.
Winding pipe
10
E1 cable
E1 transfer cable
Thread the E1 cable through the grounding clip. Then, tighten the screw on the grounding clip to make the shielding layer of the E1 cable in full contact with the grounding clip. Finally, connect the PGND cable on the grounding clip to the grounding bolt of the APM30.
Shielding layer of the E1 cable
INSIDE
OUTSIDE
E1/T1
11
OUTSIDE FE0
FE0
Thread the FE cable through the grounding clip. Then, tighten the screw on the grounding clip to make the shielding layer of the FE cable in full contact with the grounding clip. Finally, connect the PGND cable on the grounding clip to the grounding bolt of the APM30.
Shielding layer of the FE cable
12
MON1
MON0
RS485
13
Twisted pair
TX+ TX-
Twisted pair
RX+ RX-
14
No.
Cable
Installation Position One end is connected to... The other end is connected to... PWR port on the BBU INSIDE port on the UELP External transmission device MON1 port on the BBU
1 2 3 4
BBU power cable E1 transfer cable E1 cable Monitoring signal cable CPRI optical cable
LOAD3 terminal of the PDU E1/T1 port on the WMPT OUTSIDE port on the UELP COM IN port on the HEUA
15
16
No.
Cable
Installation Position One end is connected to... The other end is connected to... PWR port on the BBU INSIDE port on the UELP External transmission device MON1 port on the BBU
1 2 3 4
BBU power cable E1 surge protection transfer cable E1 cable Monitoring signal cable CPRI optical cable
LOAD3 terminal of the PDU E1/T1 port on the WMPT OUTSIDE port on the UELP COM IN port on the HEUA
17
Pin assignment of the monitoring signal cable of the cabinet Pin on the RJ45 Connector
X1.1 X1.2 X1.3 X1.6 X1.5 X1.4 X1.7 X1.8
Wire Color
Wire Type
Twisted pair
Twisted pair
Twisted pair
Twisted pair
18
No.
Cable From...
BBU power cable E1 cable FE cable (optional) Monitoring signal cable CPRI optical cable
2 3
19
1. 25 mm on the left of the BBU for ventilation 2. 25 mm on the right of the BBU for ventilation 3. 70 mm in front of the BBU for cabling
Slide the BBU case into the cabinet. Then, tighten the four M6 screws.
20
PGND cable
PWR
EXT-ALM0
MON1
21
E1/T1 E1/T1
Insert the optical module into the CPRI0, CPRI1, or CPRI2 port. Turn outwards the puller on the optical module.
Remove the dustproof caps from the optical connectors. Insert the optical connector at one end of the CPRI optical cable into the optical module. Lead the CPRI optical cable out of the cabinet along the left side of the cabinet.
Winding pipe
22
SN
Cable
Installation Position One End Connected to... The Other End Connected to...
Power supply socket on the RRU CPRI port on the RRU External transmission equipment External monitoring equipment
2 3
Monitoring signal cable BBU power cable DCDU power cable PGND cable
5 6 7
PWR port on the BBU DC input port on the DCDU-03 Grounding bolt on the equipment
23
A single BBU
24
2. Place the BBU against the wall, and then use the marking pen to mark the holes of the mounting ears for wall installation.
wall
BBU
55mm60mm
20mm
25
Flat washer
Spring washer
26
55mm60mm
20mm
27
No.
Cable From...
LOAD6 terminal on the DCDU External transmission device External transmission device RS232/RS422 port on the PMU
E1 cable
Monitoring signal cable between the PMU and the BBU CPRI optical cable
28
Slide the BBU case into the PS4890 cabinet. Then, tighten the four M6 screws.
29
LOAD 6
PWR
30
Install the BBU alarm cable (optional). Install the monitoring signal cable between the PMU and the BBU.
RS232/RS422
MON0
EXT ALM1
31
Optical module
Puller
Remove the dustproof caps from the optical connectors. Insert the optical connector at one end of the CPRI optical cable into the optical module. lead the CPRI optical cable out of the cabinet along the left side of the cabinet.
E1/T1
Winding pipe
32
No.
Cable
PGND cable
LOAD6 output terminal on the DCDU E1/T1 port on the WMPT OUTSIDE port on the UELP CPRI port on the BBU
4 5 6
INSIDE port on the UELP External transmission device CPRI port on the RRU
33
Bolt M10110
34
35
NEG(-) RNT(+)
LOAD6
36
Shielding layer
37
Optical module
Puller
3. Remove the dustproof caps from the optical connectors. 4. Insert the optical connector at one end of the CPRI optical cable into the optical module. lead the CPRI optical cable out of the cabinet along the left side of the cabinet.
38
No.
Cable From...
1 2 3 4
LOAD6 terminal of the PDU E1/T1 port on the WMPT OUTSIDE port on the UELP Wiring terminal of cabinet monitoring CPRI port on the BBU
39
Slide the BBU case into the TMC cabinet. Then, tighten the four M6 screws.
a. Fix the RJ45 connector at one end of the alarm cable to the EXT_ALM1 port on the BBU. b. Connect the two bare terminals X1.4 (blue) and X1.5 (white) to the alarm wiring terminals on the door status sensor. c. Connect the two bare terminals X1.1 (white) and X1.2 (orange) to the OUT+ and OUT- alarm wiring terminals on the APMI. d. Connect the two bare terminals X1.3 (white) and X1.6 (green) to the alarm wiring terminals on the DCDU.
40
No.
Cable From...
1 2 3 4 5
CPRI optical cable E1 transfer cable E1 cable BBU power cable Monitoring signal cable
CPRI port on the BBU E1/T1 port on the WMPT OUTSIDE port on the UELP LOAD6 terminal on the PDU Wiring terminal of cabinet monitoring
41
a No
End
a The normal status of LED on the WMPT is as follows: RUN LED: 1s ON, 1s OFF (blinking at 0.5 Hz) ALM LED: OFF ACT LED: ON The normal status of LED on the UBFA is as follows: STATE LED: Green 1s ON, 1s OFF (blinking at 0.5 Hz) The normal status of LED on the UPEU is as follows: RUN LED: ON The normal status of LED on the WBBP is as follows: RUN LED: 1s ON, 1s OFF (blinking at 0.5 Hz) ALM LED: OFF
42
12 Reference c a
Cable List
Cable PGND cable Connector OT terminal OT terminal Connects to Grounding bolt of the BBU3900 Protection grounding bar
3V3 connector Bare wire. The connector needs to be made on site according to the field requirements. (The following figure shows the BBU power cable by taking OT terminals as an example.)
DLC connector
Connect the fiber tails labeled 1A and 1B to the CPRI_W port on the RRU Connect the fiber tails labeled 2A and 2B to one of the CPRI0 to CPRI3 ports on the WBBP
DLC connector
E1 cable
E1/T1 port on the WMPT, or OUTSIDE port on the UELP Peer device
43
12 Reference c a
Cable List
Connector DB26 male connector DB25 male connector Connects to PWR port on the UPEU E1/T1 port on the WMPT
FE cable
FE transfer cable
FE0 port on the WMPT FE0 port near the INSIDE label on the UFLP
44
12 Reference a
Cable List
Connector Be connected RJ45 connector Connects to APMI MON1 port on the UPEU
Cable
APMI-BBU Monitoring signal cable
RJ45 connector
Alarm cable
RJ45 connector
RJ45 connector
45
12 Reference b
Item Dimensions Weight Input voltage
Wear an ESD wrist strap or a pair of ESD gloves when performing operations related to the boards, as shown in the figure below.
ESD strap
ESD gloves
46
12 Reference c
Checking the DIP Switches of the BBU
2. Set the DIP switches of the BBU. Settings of the DIP switches on the UELP
75-ohm E1 Mode
Other Modes
75-ohm E1 Mode
120-ohm E1 Mode
47
12 Reference ed
Pin Assignment of the BBU Signal Cables
75-ohm E1 cable Pin on the DB26 Male Connector X1.1 X1.2 X1.3 X1.4 X1.5 X1.6 X1.7 X1.8 X1.19 X1.20 X1.21 X1.22 X1.23 X1.24 X1.25 X1.26 Tip Ring Tip Ring Tip Ring Tip Ring Tip Ring Tip Ring Tip Ring Tip Ring 8 6 4 2 7 5 3 1 RX1+ RX1RX2+ RX2RX3+ RX3RX4+ RX4TX1+ TX1TX2+ TX2TX3+ TX3TX4+ TX4Wire Type Coaxial SN. Label
48
12 Reference d
Pin Assignment of the BBU Signal Cables
120-ohm E1 cable Pin on the DB26 Male Connector X1.1 X1.2 X1.3 X1.4 X1.5 X1.6 X1.7 X1.8 X1.19 X1.20 X1.21 X1.22 X1.23 X1.24 X1.25 X1.26 Blue Twisted pair White Orange White Green Twisted pair White Brown Twisted pair White Grey Twisted pair White Blue Twisted pair Red Orange Twisted pair Red Green Twisted pair Red TX4TX3TX4+ TX2TX3+ TX1TX2+ RX4TX1+ RX3RX4+ Twisted pair RX1RX2+ RX2RX3+ RX1+ Wire Color Wire Type Label
49
12 Reference d
Pin Assignment of the BBU Signal Cables
FE cable Pin on the RJ45 Connector X1.2 X1.1 X1.6 X1.3 X1.4 X1.5 X1.8 X1.7 Wire Color Wire Type Pin on the RJ45 Connector X2.2 X2.1 Twisted pair X2.6 X2.3 Twisted pair X2.4 X2.5 Twisted pair X2.8 X2.7
Twisted pair
Monitoring signal cable between the APMI and the BBU Pin on the RJ45 Connector Wire Color Pins on the X2, X3, X4, and X5 X1.1 White X2 Twisted pair X1.2 Orange X3 Twisted pair Twisted pair X1.5 White X5 Twisted pair 50 RXTXTX+ Wire Type Port on the APMI
X1.4
Blue
X4
RX+
12 Reference d
Pin Assignment of the BBU Signal Cables
EMUA monitoring signal cable Pin on the RJ45 Connector Pin on the DB9 Male Connector X2.3 Wire Color Wire Type Port on the APMI
X1.1
White
Twisted pair
TX+
X1.2
X2.7
Orange
Twisted pair
TX-
X1.4
X2.2
Blue
Twisted pair
RX+
X1.5
X2.6
White
Twisted pair
RX-
Alarm cable Pin on the RJ45 Connector X1.1 X1.2 X1.3 X1.6 X1.5 X1.4 X1.7 X1.8 Pin on the RJ45 Connector X2.1 X2.2 X2.3 X2.6 X2.5 X2.4 X2.7 X2.8 White/orange Orange White/green Green White/blue Blue White/brown Brown Twisted pair Twisted pair Twisted pair Twisted pair Wire Color Wire Type
51