Está en la página 1de 1

CHEMCAD 6.2.

0
Simulation: Caldera 05
19:50:39
FLOW SUMMARIES:

Page 1
lazaro1

Date: 09/19/2012

Time:

Line Sizing for Stream 26


Stream Properties:
- - Overall - Mass flow kg/h
Actual dens kg/m3
- - Vapor only - Mass flow kg/h
Actual dens kg/m3
Visc cP
- - Liquid only - Mass flow kg/h
Actual dens kg/m3
Visc cP

42105.0000
21.5909
39999.7455
20.5395
0.0191
2105.2513
786.9941
0.1052

Pipe Parameters:
Schedule
Flow Regime
Pipe ID in
Nominal Dia. in
- - Overall - Press Drop psi/100ft
Velocity ft/sec
- - Vapor only - Reynolds Number
Friction Factor
Press Drop psi/100ft
- - Liquid only - Reynolds Number
Friction Factor
Press Drop psi/100ft

Calculated
10
Distributed
8.3290
8.0000

Next larger
10
Segregated
10.9050
10.0000

Next smaller
10
Distributed
6.7003
6.0000

0.8604
50.5302

0.1985
29.4769

2.5398
78.0820

0.0
0.0000
0.0000

0.0
0.0000
0.0000

0.0
0.0000
0.0000

0.0
0.0000
0.0000

0.0
0.0000
0.0000

0.0
0.0000
0.0000

También podría gustarte